Forest Department Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Forest Department - FD Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date16 May 2024
Closing DateCancelled
Tender Amount₹ 14,69,263 
Notes
Download

Costs

Summary

Erecting Solar Hanging Fencing From Edupuzha To Ambedkar Colony Road (2.00 Km) In Ayyankunnu Panchayath, Iritty Section Under Kottiyoor Range During 2023-24

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
od355951/2023_2024 : design supply and commissioning of solar power generating system and hanging fence as per field condition and instruction as per engineer incharge

2000

-

-

... More
od355952/2023_2024 : providing warning signs poly-rthlene plastic with statutory colour and signs

26

-

-

... More
od355953/2023_2024 : providing earthing system must contain earth mixture capable of retaining moisture and 8mm dia stainless steel rod non rusting quality of 4feet long

42

-

-

... More
od355954/2023_2024 : providing bullets(connectors)-copper material or aluminium or stainless steel material having an inner core hole size of 2.5mm dia ,2cm length including all cost

4000

-

-

... More
od355955/2023_2024 : providing and fixingof 50x50mm ISI make GP or GI Square pipe make of vertical raiser length of 4.25m and horizontal post guard of length 1.2m including galvanising and fastner assembly etc<br>

104

-

-

... More
od355956/2023_2024 : providing stainless steel wire 1.5mm 304 grade non rusting qualitY for main line

4260

-

-

... More
od355957/2023_2024 : providing and fixingof bottom fixture 75x75x2mm wall thickness and length of .85m ISI make GP or GI Square pipe including all fabrication cost and coveyance etc

104

-

-

... More
od355958/2023_2024 : providing stainless steel wire 1.2mm 304 grade non rusting quality

4000

-

-

... More
od355959/2023_2024 : Providing SS Wire rope 1.5mm dia and non rusting quality for hanging line

18496

-

-

... More
od355960/2023_2024 : Supplying and fixing bittom fixture bush(adopter for 75mm pipe into 50mmpipe acting as a insulator to energizethe raiser pipe,the bush must be made of virgin PP or equivalent material and UV Stabilised)including all cost and conveyance etc complete

104

-

-

... More
ELECTRICAL AND SOLAR WORKS

-

-

-

... More
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm

5

-

-

... More
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm

20

-

-

... More
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

2

-

-

... More
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

2

-

-

... More
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

2

-

-

... More
5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required

4

-

-

... More
90.6.5.6 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.

14

-

-

... More
od355961/2023_2024 : providing Energizer with following specification 24 V Energizer (1)must be <br>from a reputed company (2)must confirm to BIS standard 302-2-76 and all <br>national and international standards of safety (3)switch to high and low power <br>setting (4)solar panel option to recharge 12volt battery (5) Should possess <br>the following output characters (1)Peak o/p voltage not more than 10kv on <br>50Kload (2), o/o energy 3.5 J minimum (3)pulse duration 1.01-3.0m sec- <br>(4)Pulse interval 1.1-1.4 sec (5) peak current 7.0-8.0 A -high (6)3years <br>warranty against manufacturing defects

2

-

-

... More
od355962/2023_2024 : Supply and Installation of 12 volt 150AH Solar Tubular battery Exide/amron/Hykon or equivalent<br>with at least 5 years guarantee

4

-

-

... More
od355963/2023_2024 : Providing Digital volt meter must display fence voltage in kilowatt upto 9.9kv <br>including all cost

2

-

-

... More
od355964/2023_2024 : supply and fixing Tool Kit (cutting pliers, twisting toolkit, multimeter, double ended <br>spanner etc as requried

2

-

-

... More
od355965/2023_2024 : Providing Lead Out Cable must be double insulated withstanding <br>15KV voltage and inner core wire must be GI<br>

278

-

-

... More
od355966/2023_2024 : Supplying and drawing DC Solar cable 4 sqmm uv protected

16

-

-

... More
od355967/2023_2024 : Providing Solar module With following specification (1) 180watts 12 volt rating <br>with minimum 10years warranty against manufacturing defects of approved brand

4

-

-

... More
od355968/2023_2024 : Solar Charge Controller with display 12v/24v to regulate the charging of the battery of approved brand

2

-

-

... More
od355969/2023_2024 : supply and installing multispike Lightning arrester Must be capable of diverting stray lightning in suitable height including GI pipe for fixing and concrete/equivalent for fixing on the ground

2

-

-

... More
90.12.5.2 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.

40

-

-

... More
od355970/2023_2024 : Supply Installation and commissioning of cubicle made of GI sheet with powder coated for accommodating energizer, battery and charge controller.

2

-

-

... More
5.17 : Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.

34

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.