The Fertilisers And Chemicals Travancore Limited Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

The Fertilisers And Chemicals Travancore Limited - FACT Tender

Works
Electrical and Electronics
Eprocure
Opening Date11 Feb 2020
Closing Date3 Mar 2020
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Erection of Relay panels in respective electrical rooms having the size given below,at various locations in NP3 , NP4 and Acid Plant as per the instruction of Engineer -In- Charge. The work includes: Shifting the relay panel near the MCC room to the actual location where it is to be fixed. Fabrication of base frame with 100x50x50mm MS chanel, Painting and fixing on the floor by suitable means and fixing the panel on the base frame. 1. SC Load Centre Relay Panel -NP3 - 1.0x2.1x0.3M 2. SO2 MCC-1 Relay panel Acid - 2.0x2.1x0.3M

1

-

-

... More
Erection of Relay panels in respective electrical rooms having the size given below,at various locations in NP3 , NP4 and Acid Plant as per the instruction of Engineer -In- Charge. The work includes: Shifting the relay panel near the MCC room to the actual location where it is to be fixed. Fabrication of base frame with 100x50x50mm MS chanel, Painting and fixing on the floor by suitable means and fixing the panel on the base frame. 1. K-Mill Relay Panel -NP3 - 1.0x0.8x0.21M 2. DCDA LT MCCs (1 to 5) Relay Panel -1.0x0.8x0.21M

1

-

-

... More
Erection of Relay panels/Jn. boxes in respective electrical rooms having the size given below,at various locations in NP3 , NP4 and Acid Plant as per the instruction of Engineer -In- Charge. The work includes: Shifting the relay panel near the MCC room to the actual location where it is to be fixed. Fabrication of base frame with 100x50x50mm MS chanel, Painting and fixing on the floor by suitable means and fixing the panel on the base frame. For Junction boxes mounting on wall, suitable frame in MS angle ( 65 x 65 x 6)mm , to be fabricated painted and fixed upon which the junction box is fixed. 1. Drier Drive Relay Panel -NP3 - o.8x0.6x0.21M- on wall 2. Pollution control relay Panel -NP3 - 0.8x0.8x0.21m- on wall 3. SO2 MCC-1 Interposing Jn. Box -0.8x0.8x0.21M- on wall 4. IAC Relay Panel -NP3 - 0.8x0.8x0.21M

1

-

-

... More
Erection of Relay panels/Jn. boxes in respective electrical rooms having the size given below,at various locations in NP3 , NP4 and Acid Plant as per the instruction of Engineer -In- Charge. The work includes: Shifting the relay panel near the MCC room to the actual location where it is to be fixed. Fabrication of base frame with 100x50x50mm MS chanel, Painting and fixing on the floor by suitable means and fixing the panel on the base frame. For Junction boxes mounting on wall, suitable frame in MS angle (65x65x6)mm, to be fabricated painted and fixed upon which the junction box is fixed. 1. PAP Load Centre Relay Panel -NP3 - 0.8x1.0x0.21M 2. DCDA LT MCC-6 & SO2-2-ACID - 0.8x1.0x0.21M 3. ASPN Load Centre Relay Panel -NP4 - 0.8x1.5x0.21M

1

-

-

... More
Erection of Relay panels/Jn. boxes in respective electrical rooms having the size given below,at various locations in NP3 , NP4 and Acid Plant as per the instruction of Engineer -In- Charge. The work includes: Shifting the relay panel near the MCC room to the actual location where it is to be fixed. Fabrication of base frame with 100x50x50mm MS chanel, Painting and fixing on the floor by suitable means and fixing the panel on the base frame. For Junction boxes mounting on wall, suitable frame in MS angle ( 65x65x6)mm , to be fabricated painted and fixed upon which the junction box is fixed. 1. Bagging Load Centre (JB) - NP3- 0.25x0.25x0.21M

1

-

-

... More
Laying and clamping of armoured copper control cables of size 3c /5c /7c /13 c x 2.5 sq.mm throgh wall /ceiling /cavity floor /cable trays from each MCCs to respective Relay Panels and from each relay panel to RIO rooms as per the instructions of Engineer in-charge. Clamping of cables shall be done at an intervel of 450mm. Supply of cables shall be under FACT scope.

8500

-

-

... More
Laying and clamping of Armoured copper control cables of size 19c /24c /27c x 2.5 sq.mm armoured copper cable throgh wall / ceiling / cavity floor /cable trays from each MCCs to respective Relay Panels and from relay panels to RIO rooms as per the instructions of Engineer in-charge. Clamping shall be at an intervel of 450mm. Supply of cables shall be under FACT scope.

4200

-

-

... More
Glanding, termination and connection of armoured copper control cables upto 13c x 2.5 sq.mm (gland size of 19/ 25mm) using single compression cable glands as per the instructions of Engineer in charge. The work includes suiting the existing knockout for cable glands in the IPRP panel/ MCC, making /modifing to the required size, glanding, termination and connection using suitable cable lugs/terminal ends of the cables as per the cable schedule. Supply of cable glands shall be under scope of FACT. All other materials required shall be under the scope of contractor.

600

-

-

... More
Glanding , termination and connection of armoured copper control cables from 19c x 2.5 sq.mm upto 27c x 2.5 sq.mm (gland size of 25/32/38mm) using single compression cable glands as per the instructions of Engineer in charge. The work includes suiting the existing knockout for cable glands in the IPRP panel/ MCC, making /modifing to the required size, glanding, termination and connection of the cables using suitable cable lugs/ terminal ends as per the cable schedule. Supply of cable glands shall be of FACT scope. All other materials required shall be under the scope of contractor.

75

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.