Fertilisers And Chemicals Travancore Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Fertilisers And Chemicals Travancore Limited - FACT Tender

Works
Eprocure
Opening Date18 Jun 2020
Closing Date6 Jul 2020
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Arresting of oil leak through various flanges / joints of TELK make 11/3.45 kV, 6.3 MVA Transformer-4K (M/c Sl. No. 110089-3), Oil capacity-3215 litres. Scope of work: A) Primary inspection of the transformer. B) Draining of oil from the transformer C) Disconnection and disassembling of bushings, conservator, pipe lines, cooling fins etc. D) Disconnection of tap-changer leads and replacement of gaskets. E) Removal of band bolts and lifting upper cover to replace gasket. F) Rectification of oil leak by replacing of all old gaskets of bushings, radiators, drain plug, conservator, buchholz relay, breather & pipe line. G) Flushing the winding with new oil to clean inside. H) Tightening the inner connections. (Bushes shall also be replaced if found necessary as mentioned in item no:8 & 11) I) Reassembling of the transformer to its original shape after replacing of top cover gaskets. J) Vacuum oil filling of the transformer. K) Filtering old oil to the required level as per cl.5 of special conditions. L) Hot oil circulation till satisfactory oil test results are achieved. M) Testing of oil as per cl.5 of special conditions.. N)Pre-commissioning checks and energisation. Scope also includes thorough cleaning and repainting of transformer exterior with one coat of epoxy primer and one coat of epoxy paint.

1

-

-

... More
Transformer oil purification of TELK make 11/0.433 kV, 1.6 MVA Transformer-05C (M/c Sl. No. 110091-1), Oil capacity-2280 litres. Scope of work: A) Filtering and hot oil circulation till satisfactory oil test results is achieved. B) Testing of oil as per cl.5 of special conditions.. Vacuum oil filling method shall be followed during final filling of oil up to conservator level. The contractor shall ensure NIL air locks during final oil filling.

2280

-

-

... More
Transformer oil purification of TELK make 11/0.433 kV, 1.6 MVA Transformer-7C (M/c Sl. No. 110091-3), Oil capacity-2280 litres. Scope of work: A) Filtering and hot oil circulation till ll satisfactory oil test results is achieved. B) Testing of oil as per cl.5 of special conditions.. Vacuum oil filling method shall be followed during final filling of oil upto conservator level. The contractor shall ensure NIL air locks during final oil filling.

2280

-

-

... More
Supply and replacing the ceramic bushes on LT side of Transformer, TELK make 11/0.433 kV, 1.6 MVA Transformer-8C (M/c Sl. No. 110091-4), Oil capacity-2280 litres. Note: This is an optional item. The bushes need to be replaced only after getting written confirmation from Engineer in Charge. Assembly with existing current bolt shall be used.

2

-

-

... More
Supply and replacing the ceramic bushes on LT side of Transformer, ITL make 11/0.433 kV, 1.6 MVA Transformer-12K (M/c Sl. No. 9104), Oil capacity-1220 litres. Note: This is an optional item. The bushes need to be replaced only after getting written confirmation from Engineer in Charge. Assembly with existing current bolt shall be used.

2

-

-

... More
Supply and replacing the ceramic bushes on LT side of Transformer, TELK make 11/3.45 kV, 6.3 MVA Transformer-4K (M/c Sl. No. 110089-3), Oil capacity-3215 litres. Note: This is an optional item. The bushes need to be replaced only after getting written confirmation from Engineer in Charge. Assembly with existing current bolt shall be used.

2

-

-

... More
Supply and replacing the ceramic bushes on HT side of Transformer, TELK make 11/0.433 kV, 1.6 MVA Transformer-8C (M/c Sl. No. 110091-4), Oil capacity-2280 litres. Note: This is an optional item. The bushes need to be replaced only after getting written confirmation from Engineer in Charge. Assembly with existing current bolt shall be used.

1

-

-

... More
Supply and replacing the ceramic bushes on HT side of Transformer, ITL make 11/0.433 kV, 1.6 MVA Transformer-12K (M/c Sl. No. 9104), Oil capacity-1220 litres. Note: This is an optional item. The bushes need to be replaced only after getting written confirmation from Engineer in Charge. Assembly with existing current bolt shall be used.

1

-

-

... More
Supply and replacing the ceramic bushes on HT side of Transformer, TELK make 11/3.45 kV, 6.3 MVA Transformer-4K (M/c Sl. No. 110089-3), Oil capacity-3215 litres. Note: This is an optional item. The bushes need to be replaced only after getting written confirmation from Engineer in Charge. Assembly with existing current bolt shall be used

1

-

-

... More
Supply of gaskets and oil seals for the transformer, TELK make 11/0.433 kV, 1.6 MVA Transformer-8C (M/c Sl. No. 110091-4), Oil capacity-2280 litres. Specifications of Rubberised Cork Gasket: The supplied gasket shall confirm to IS and following specifications: Type : C- very good oil resistant Grade: R C-70 C Sp. Gravity: 0.7- 0.8 Hardness: 70 +/- 5 irhd Compressibility@ 28 Kg/cm2- 30 +/- 5% for 6.3 mm 33 +/- 5 % for 9.6 mm Recovery@ 28 Kg/cm2- 80 (minimum)

1

-

-

... More
Supply of gaskets and oil seals for the transformer, ITL make 11/0.433 kV, 1.6 MVA Transformer-12K (M/c Sl. No. 9104), Oil capacity-1220 litres. Specifications of Rubberized Cork Gasket: The supplied gasket shall confirm to IS and following specifications: Type : C- very good oil resistant Grade: R C-70 C Sp. Gravity: 0.7- 0.8 Hardness: 70 +/- 5 irhd Compressibility@ 28 Kg/cm2- 30 +/- 5% for 6.3 mm 33 +/- 5 % for 9.6 mm Recovery@ 28 Kg/cm2- 80 (minimum)

1

-

-

... More
Supply of gaskets and oil seals for the transformer, TELK make 11/3.45 kV, 6.3 MVA Transformer-4K (M/c Sl. No. 110089-3), Oil capacity-3215 litres. Specifications of Rubberized Cork Gasket: The supplied gasket shall confirm to IS and following specifications: Type : C- very good oil resistant Grade: R C-70 C Sp. Gravity: 0.7- 0.8 Hardness: 70 +/- 5 irhd Compressibility@ 28 Kg/cm2- 30 +/- 5% for 6.3 mm 33 +/- 5 % for 9.6 mm Recovery@ 28 Kg/cm2- 80 (minimum)

1

-

-

... More
Supply and fixing of new Silica gel air breather for 1250 kVA / 1600 kVA Transformer

6

-

-

... More
Supply and fixing of Buchholz relay for 1250 kVA / 1600 kVA Transformer

2

-

-

... More
Supply and fixing of Buchholz relay for 6300 kVA Transformer

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.