District Nirmithi Kendra Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 20,700Document Cost
₹ 1,953Tender Fee
Refer Documents
Summary
Revenue Department- Plan Schemes- Basic Amenities In Village Offices (2019 20)-nadama Village Office- Additional Room
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_DNKEK_556028_1Bid Award Id
ViewTender No
EDNK 19(A-6)/2021Tender Authority
District Nirmithi Kendra ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation
trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
14.85
-
277.58
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.74
-
6370.44
... More
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement
concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth
level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
13.99
-
6734.9
... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not
exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift up to 1.5 m.
16.2
-
241.71
... More
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams,
girders, bressumers and cantilevers with water proofply 12 mm thick.
44.56
-
705.98
... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth
and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level
excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand :
3 graded stone aggregate 20 mm nominal size)
0.5
-
10239.65
... More
Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size
confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM
1:6 ( 1 cement : 6 coarse sand) etc complete
17.78
-
6529.32
... More
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
7.84
-
10743.34
... More
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
46.24
-
762.57
... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and
binding all complete upto plinth levelThermo - echanically Treated bars of grade Fe-500D or more
833
-
91.89
... More
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed
and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or
dash fastener shall be paid for separately), using good quality Anjili wood /jack wood
0.04
-
102697.84
... More
Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows,
30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with
necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f
Engineer in- charge. using Anjili/ Jack wood
1.8
-
2831.12
... More
Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or
round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden
frames with rawl plugs screws etc
97.5
-
201.91
... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up
standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS :
733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the
gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.
Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever
required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel
screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing,
paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium
(minimum thickness of powder coating 50 micron)
53.3
-
502.05
... More
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
48
-
601.16
... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM
rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer -
in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0
mm thickness
6.5
-
1099.91
... More
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
221.38
-
293.61
... More
9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
68.1
-
272.32
... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
38.47
-
1651.07
... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
5.4
-
208.75
... More
Applying priming coat:With ready mixed pink or Grey primer of approved and manufacture on wood work
(hard and soft wood)
4.73
-
62.8
... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or
more coats on new work
4.73
-
133.72
... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
289.48
-
66.04
... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two
or more coats on new work
289.48
-
141.51
... More
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade
made by block making machine with strong vibratory compaction, of approved size, design & shape, laid
in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the
joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
15
-
945.6
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size)
0.05
-
7469.72
... More
Fixtures and fastners
-
-
-
... More
Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc,
complete:100x58x1.90mm.
3
-
41.07
... More
Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc,
complete:50x37x1.50 mm
24
-
17.24
... More
Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:200x10 mm
1
-
329.92
... More
Providing and fixing iron hooks and eyes: 100 mm
24
-
13.27
... More
Supplying and fixing 250 mm MS altrop
1
-
274.38
... More
ELECTRICAL WORKS
-
-
-
... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated
copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic
laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated
copper conductor single core cable etc as required.Group A
5
-
912.58
... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate
switch box including connections but excluding modular plate etc. as required.
4
-
380.24
... More
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with
specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,
fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including
providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of
copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type
metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP
switches and making good the surface of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the
box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined
plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light
points
4
-
356.18
... More
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with
specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988,
fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00
sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including
providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of
copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type
metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP
switches and making good the surface of wall, colour washing etc. complete. All the terminations in the
switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the
box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent
Plug - Medium Point
2
-
612.76
... More
Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using
standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC
insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended
original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod ,canopies, shackles and blades working on 230V/240V single phase A/C
4
-
1778.33
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements