Directorate Of Panchayat Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Directorate Of Panchayat - DP Tender

Goods
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date11 Feb 2025
Closing Date18 Feb 2025
Tender Amount₹ 15,00,000 
Notes
Download

Costs

Summary

Purchaice And Instalation Of Generator

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm

5

-

-

... More
90.6.4.54:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 4 Run

4

-

-

... More
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm

6

-

-

... More
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm

5

-

-

... More
90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm

3

-

-

... More
90.11.1.18:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43)

1

-

-

... More
90.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL

1

-

-

... More
OD401497/2024-2025:Supply, fabrication & erection suitable size metal enclosure on wall , made out of 1.63 mm metal sheet with 63A TP MCCB, three nos LED indication lamps controlled by three nos 16A fuse with 2A HRC & space for accommodating 63A 4pole RCCB

1

-

-

... More
OD401498/2024-2025:Supply & providing 40A TPMCB in existing VDB & giving connection as required.

1

-

-

... More
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole

2

-

-

... More
OD401541/2024-2025:Supply & fabricating cubicle panal borad with 63 A ,4 pole on load COS , 6 nos LED indication lamp, 3 nos 2A fuse unit etc. on wall and giving connection as required.

1

-

-

... More
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole

3

-

-

... More
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps

1

-

-

... More
OD392274/2024-2025:Supply ,conveyance, installation, testing and commissioning of PCBC IV norms three phase 40 KVA DG set with AMF panel & it's standard accessories ,battery and other accessories with approved as a complete set including first fill of lube oil & engine oil & Engine safeties and all other standard accessories including CPCB approved acoustic enclosure etc.as required. Kirloskar/ Asokleyland / Koel / Cummins with fittings as detailed below.Engine.1.; Flywheel and flywheel housing 2. 12 V DC electric start arrangement 3. Exhaust Silencer & residential Type Silencer 4. Fuel Filter (Pre and Micro) 5. Lube oil filter & type 6. Radiator (For liquid cooled DG set only) 7. Dry Type Air Cleaner& 8. Battery charging Alternator &9. Fuel hoses 10. Maintenance manual and spare parts catalogue&11. Radiator fan (For liquid cooled DG set only)&12. Fuel injection pump with mechanical governor and fuel feed pump&13. Closed Coupled Engine with inbuilt Anti Vibration Mounting Pads 14. First Fill of Lube Oil 15. First fill of Coolant ( Life is 3000 running hours or 3 years) Alternator& KOEL/ KEL/ STAMFORD make self & excited, self regulated, screen protected, drip proof alternator with static excitation system, capable of developing rated output at 415V, 0.8 p.f. 50 Hz when running at 1500 RPM at NTP conditions and conforms to the IS 4722 standards.<br> Control panel consisting-Genset controller having Alternator parameter like voltage, frequency, Amps, KW, KVAR,PF etc.,3 nos current transformer.KW hour meter, bus bar, indication lamps, MCB, instruments fuses ,earthing studs. AMF panel- Auto start stop panel , two nos out going MCB/MCCB & battery charger. etc.

1

-

-

... More
90.12.7.1:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 4 sq mm with factory made clamp

25

-

-

... More
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp

60

-

-

... More
90.12.1.41:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).4 core 16 sq mm

10

-

-

... More
90.12.7.28:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp

10

-

-

... More
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)

2

-

-

... More
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)

6

-

-

... More
9.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)

2

-

-

... More
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)

4

-

-

... More
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)

12

-

-

... More
90.16.5.6:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.6. mm ( 4 SWG)

16

-

-

... More
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)

25

-

-

... More
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)

120

-

-

... More
90.16.1.6:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required6.00 mm copper conductor (4 SWG)

50

-

-

... More
OD392268/2024-2025:Supply & providing 25 x 3 mm copper strip in wall as required as earth bus.

0.6

-

-

... More
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch

1

-

-

... More
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet

1

-

-

... More
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)

1

-

-

... More
OD392285/2024-2025:Supply & providing 25x6 mm brass bolt , nut with washers on the existing MS box/earth bus etc. as required including drilling holes as required.

15

-

-

... More
OD392277/2024-2025:Supply & providing 12x3 mm brass bolt & nut with washers on the existing MS box/earth bus etc. as required including drilling holes as required.

10

-

-

... More
14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.

0.55

-

-

... More
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).

1.5

-

-

... More
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels

4

-

-

... More
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.

4

-

-

... More
OD392292/2024-2025:Supply & laying ,jointing of DWC pipe 40/32 mm in the existing trench for protection of UG cable.

25

-

-

... More
OD392280/2024-2025:Supply & clamping 50/38mm dia size DWC pipe clamping in position as required.

25

-

-

... More
OD392270/2024-2025:Supply & fitting 65 mm dia. or nearest size MS. 'C; class pipe as extra length of DG exhaust pipe as required.

10

-

-

... More
OD392284/2024-2025:Supply & fabricating suitable size support made out of 35x35x5 mm or nearest size angle iron as required including painting as required.

50

-

-

... More
OD392272/2024-2025:Supply of Diesel for DG test running.

90

-

-

... More
OD392278/2024-2025:Supply & providing 5 kg / nearest size Dry chemical powder type fire extinguisher with hose & clamps fixing it to wall as required.

2

-

-

... More
OD392276/2024-2025:Painting letters/figures of the following sizes with enamel paint as identification mark to SB,DB,panel board etc. as required. 2.5x4 cm. size

100

-

-

... More
OD392273/2024-2025:Supply & providing 2.5mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to with stand 11KV dielectric strength.

4

-

-

... More
OD392275/2024-2025:Supply & laying FIRST AID BOX in position

1

-

-

... More
OD392281/2024-2025:Supply & fitting Alu. Anodised DNB of size 200x150 mm with inscriptions both in english & malayalam and conventional skull & bone in red colour.

2

-

-

... More
OD392279/2024-2025:Supply & providing extra battery charger 20 Amps fitted in position as required.

1

-

-

... More
90.6.5.19:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm

25

-

-

... More
OD392282/2024-2025:Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel .

80

-

-

... More
OD392283/2024-2025:Charges for preparing documents for submitting electrical inspectorate for initial & final approval.

1

-

-

... More
OD392269/2024-2025:Supply & providing fire buckets with stand in position as required.

3

-

-

... More
90.16.2.3:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.32 mm dia G.I pipe ( medium class)

15

-

-

... More
OD392299/2024-2025:Supply & providing 63A 2 way neutral link on the existing meter box

2

-

-

... More
OD392286/2024-2025:Supply & providing 63A HRC fuse base with 40A, HRC fuse link in position.

6

-

-

... More
OD401500/2024-2025:Supply & installation of dust & vermin proof wall mounting meterbox (650x350x250 mm) sintex make (GSMB- 6535) with base plate suitable to fix energy meter,cut outs ,NL etc. on wall using suitable nut ,bolt etc.

1

-

-

... More
OD392271/2024-2025:Earthing with 40 mm dia. medium class GI earth pipe 2.5 Mtr. long, providing 12mm dia. drilled holes minimum 20 nos along the entire length in alternate arrangement ,providing 40x25 mm GI reducer at top, test joint using 2 nos ,25x3 mm GI strip minimum size 25CM suitably shaped & tightly clamped to the pipe using 25x6 mm steel bolt & nut,washer,providing 2 nos 6 mm dia. drilled holes for clamping & bolting earth lead ,making masonary chamber with cover plate having locking arrangement etc. (charcoal & salt as required shall be filled at 30 CM dia .around the earth electrode)

3

-

-

... More
OD392293/2024-2025:Dismantling the existing floor tiles from it's position, laying UG cable in position & refitting floor tiles as required.

4

-

-

... More
OD392290/2024-2025: Electrical inspectorate inspection charges ,KSEB meter shifting charges. actual amount reimbursed producing original bills. Non - competive rate.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.