Directorate Of Panchayat Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Directorate Of Panchayat - DP Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date9 Sep 2024
Closing Date24 Sep 2024
Tender Amount₹ 1,50,156
Costs
EMD
₹ 3,754Document Cost
₹ 555Tender Fee
Refer Documents
Summary
Electrification Of Various Anganawadi
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DP_690064_1Tender No
LSGD/CELSGD/10802/2024-2025Tender Authority
Directorate Of Panchayat ViewPurchaser Address
-Website
http://https://dop.lsgkerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
24
4784
199.37
1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
20
4793
239.68
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
24
1550
64.62
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
4
359
89.83
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
4
1918
479.72
1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
2
1393
696.84
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
6
3553
592.25
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
2
4408
2204.42
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
2
817
408.97
90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
2
351
175.66
OD274930/2023-2024:Supply, Conveyance, Installation, testing and commissioning of 400mm Sweep Wall mount Fan
4
13114
3278.6
OD274931/2023-2024:Supply, Installation of Single pole 5/6 Amps Modular Socket in the existing front plate and giving necessary connections as required
4
398
99.59
OD274932/2023-2024:Supply, Installation of Single pole 5/6 Amps One way modular switch in the existing front plate and giving necessary connections as required
4
198
49.66
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
8
2324
290.59
90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
2
2505
1252.63
90.15.4.5:Supply Conveyance, installation, testing and commissioning of 40W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
2
10047
5023.64
OD274933/2023-2024:Supply, installation testing and commissioning exhaust fan of size 150mm sweep Light duty in plastic body with self opening lowers in the existing opening, fixing necessary anchor bolts/bolt and nut with 0.3m,110mm PVC pipe neatly plastered in the existing exhaust fan hole, making good the damages, color washing etc as required and giving connection with required length of 24/0.20mm PVC insulted and PVC Sheathed 650/1100V grade 3 core round copper conductor flexible wire
2
2636
1318.08
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
2
956
478.1
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
20
2157
107.86
OD274934/2023-2024:Supply and fixing of 9W LED Bulb, as required
20
3210
160.5
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
8
626
78.32
2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door
2
5868
2934.21
2.10.2:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural
2
1302
651.26
2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2
5013
2506.59
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
24
5726
238.59
2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
4
4059
1014.85
OD274935/2023-2024:Supply and installation of dust and Vermi proof, single phase Syntex meter board (GS-MB-3525) [350 x 250 x 150] and to fix KSEB meters, fuse Unit, CT, RCCB etc as required including fixing it on wall, making good the damages, color washing etc as required.
2
6036
3018.08
OD274936/2023-2024:Supplying and fixing 32A, Bakelite HRC fuse with HRC fuse link with connection, in the existing meter board
2
777
388.79
OD274937/2023-2024:Supplying and fixing 32A, 2 way Neutral link mounted on DMC/SMC base with connection, in the existing meter board
2
436
218.05
5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
2
12311
6155.87
5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
12
3694
307.89
5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
4
613
153.45
Evaluation Notes How It Works ?