Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 6,285Document Cost
₹ 555Tender Fee
Refer Documents
Summary
Benglamkunnu Dws Three Phase Line Pulling, Purchase And Installation Of Motor
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_DP_710417_1Tender No
SC4-26-2/2023-24Tender Authority
Directorate Of Panchayat ViewPurchaser Address
-Website
http://https://dop.lsgkerala.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
OD231635/2024-2025:Supply and installation of Type 1+2,Surge Protection Device having Configuration 3P+N,4module,Maximum Discharge Current-Imax upto 100KA,,in the existing enclosure and giving connections as required (L&T Make AUSP123PN100 or equivalent)
1
-
-
... More
OD231621/2024-2025:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.
1
-
-
... More
90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
1
-
-
... More
90.3.20.3:Supply & installation of light fittings on TW round block <br> Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
1
-
-
... More
90.6.6.5:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.10 sq mm
20
-
-
... More
OD231619/2024-2025:Supply and Providing 60 mm A UPVC pipe red CE Cutting connecting with accessories etc
10
-
-
... More
OD231626/2024-2025:Supply and providing UPVC Adaptor Set 60Mm DC CI
1
-
-
... More
OD231625/2024-2025:Supply and fitting KARTAR NRV CI HEAVY ISI 65MM[21/2" using required bolt and nut and flange etc
1
-
-
... More
OD231618/2024-2025:Supply and fitting 65 mm KARTAR Sluice valve on existing GI pipe with flanges etc
1
-
-
... More
OD231617/2024-2025:Supply and provide clamp set for pump set
1
-
-
... More
OD231620/2024-2025:Supply and fitting 63 mm GI Bend on pumping main with flanges welded and nut bolt etc on pumping main.
1
-
-
... More
OD231615/2024-2025:Supply and Providing 63 mm GI pipe (Medium class) Cutting threading welding and with accessaries etc
5
-
-
... More
OD231623/2024-2025:S&I of Pressure meter with acessories and stopper valve, ball valve etc on delivery side of 63 mm GI pipe line as required
1
-
-
... More
OD231613/2024-2025:Supply and fitting 60 mm flange with bolt and nut duly welded
12
-
-
... More
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
10
-
-
... More
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
10
-
-
... More
90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm
10
-
-
... More
90.6.4.54:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.10.00 sq.mm 4 Run
10
-
-
... More
OD231636/2024-2025:Supply and Installation of Thermo Circuit Breaker Box Glass Door Enclosure 8 way IP65 HENSEL make for surge protection device
1
-
-
... More
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
1
-
-
... More
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1
-
-
... More
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1
-
-
... More
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
1
-
-
... More
2.10.5:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
1
-
-
... More
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
1
-
-
... More
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
8
-
-
... More
OD231616/2024-2025: Earthing with G.I. earth plate 600mm X600 mm X 6 mm thick with watering pipe 1.7 metre long and test joint using 2 nos ,25x3mm GI Strip with sufficient drilled holes minimum size 25 cm suitably shaped and tightly clamped to the watering pipe using 25x6 mm steel bolts nut and washer and providing 2 nos, 20x3 mm GI strip from test joint to earth plate bottom level clamped at 2 locations on the plate and on the test joint bolted with steel bolts,nuts etc ,providing GI funnel welded with the watering pipe and making masonry chamber built with bricks and duly plasterd and providing cast iron cover plate with charcoal etc complete
3
-
-
... More
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
35
-
-
... More
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
12
-
-
... More
OD231624/2024-2025:Supply and providing of 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
12
-
-
... More
OD231728/2024-2025:Supply and Installation of dust and vermin proof,wall mounting,Sintex meter box of size 650*350*210mm suitable for fixing KSEB meter,fuse units,neutral link etc. (GSMB6535)
1
-
-
... More
OD231627/2024-2025:Supply and providing L&T make HRC fuse base with 63A Fuse Link to the Meter Box as required and giving connection .
3
-
-
... More
OD231612/2024-2025:S&F 32 A Two way N/L mounted on DMC/ SMC base connection etc
1
-
-
... More
OD232011/2024-2025:Supply and providing anchor bolt hook type on wall/parapet for binding KSEB Service connection capable as required
1
-
-
... More
OD231628/2024-2025:Charges for preparing drawing of the complete Electrical installation after completion of the present work and preparing completion report with KSEB
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements