Council Of Scientific And Industrial Research Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Council Of Scientific And Industrial Research - CSIR Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date5 Nov 2024
Closing Soon19 Nov 2024
Tender Amount₹ 6,98,978
Costs
EMD
₹ 13,980Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CSIR_213406_1Tender No
NIIST/WKS/ELE/038/2024-25Tender Authority
Council Of Scientific And Industrial Research ViewPurchaser Address
-Website
http://etenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Electrical Renovation work adjacent to the library for extending the ITSU facility in CSIR-NIIST Campus, Trivandrum
BOQ Items
Single pole-6A
4
-
-
Single pole-16A
12
-
-
Single pole-32A
8
-
-
Triple Pole-32A
2
-
-
Supplying and fixing of following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing, etc. as required. (But without MCB/RCCB/Isolator) 8-way, Double door
1
-
-
Supplying and fixing following rating, double pole, ( single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commisioning etc. as required. 25A
1
-
-
Supplying and fixing following rating, four pole, ( three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commisioning etc. as required. 63A
1
-
-
WIRING FOR LIGHT / FAN / PLUG SOCKETS, ETC
-
-
-
Wiring for light point /fan/exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc . as required. Group C
15
-
-
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FLRS PVC insulated copper conductor , single core cable in surface / recessed medium class PVC conduit as required. 2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire
150
-
-
Supplying and drawing following size of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3X2.5 sq.mm
100
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on the surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non-residential buildings).
24
-
-
Supplying and fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin5/6A modular socket outlet and 5/6A modular switch, connections etc. as required.
5
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on the surface or in recess, including providing and fixing 6 pin 5/6A & 15/16 A modular socket outlet and 15/16A modular switch, connections, etc. as required.
22
-
-
ENCLOSURES
-
-
-
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
7
-
-
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
80
-
-
LIGHT FIXTURES
-
-
-
Supply of 2'x2' LED recess Luminaire with CRCA housing and fully diffused prismatic diffuser with the following specifications: 230V, 50Hz supply, minimum lumens ≥3600, efficiency ≥ 100 lumens / Watt, Driver efficiency ≥ 85%, ≥4KV Surge protection, short circuit and overload protection, THD 0.9, CRI 80, CCT of 6500K (cool day light), IP20 protected, Lumen as per LM80 and life of LED @ 50k hrs, EMC compliance and confirming to IS: 10322 and IS:16108 with latest amendments.
15
-
-
Installation, testing, commisioning of wall bracket/ ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
15
-
-
BLDC FANS
-
-
-
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
4
-
-
CABLE TRAYS
-
-
-
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perfoaration not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness
20
-
-
CABLE SUPPLY, LAYING & END TERMINATIONS
-
-
-
Supplying of one number 4 core 25 sq.mm, 1.1 KV grade, XLPE aluminium armoured power cable
55
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade following size on cable tray as required. Upto 35 sq.mm (clamped with 1mm thick saddle)
30
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade following size on wall surface as required. Upto 35 sq.mm (clamped with 1mm thick saddle)
60
-
-
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade following size on cable tray as required. Upto 185 sq.mm (clamped with 25/40X3 mm MS flat clamp)
20
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE alumium conductor cable of 1.1 KV grade as required. 4X25 sq.mm (28mm)
2
-
-
AIR CONDITIONERS
-
-
-
Supply, Installation, Testing & Commissioning of at least 3 Star rated- Inverter Hi wall mounted Split Air conditioners of 2 TR capacity with R-32 or R-410a Refrigerants.
3
-
-
Extra Copper Piping (In addition of 3.0 Mtrs std Supply with the unit ) between IDU & ODU of Sizes as per manufacturer standard with thermal insulation, PVC wrapping tape etc.
18
-
-
Supply & lying of Electrical Cabling between ODU to IDU for power/Communication etc. (size and core of the Cables as per Manufacturer standard ,Cable should not be jointed between IDU & ODU)
30
-
-
Supply & fixing of Condensate Drain pump for split ACs
Max. flow 12L/h, Head 10m (flow rate 4L/h)
Sound level 21dB(A) @ 1m
Ref: Aspen Pumps-Mini Blanc or equivalent
3
-
-
Supply, fabricating , installation of 1.5/2 inch angle iron for ODU mounting as per site conditions , with necessary primer and painting
20
-
-
Supply & Installation of insulated PVC drain
pipe of 32mm diameter with insulations neatly
clamped or hanged on walls / ceiling and
connecting with nearest drain point with
Proper supports.
30
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%