Cochin Shipyard Limited Tender
... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
0Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CSL_216177_1Bid Award Id
ViewTender No
CSL/SR1/ADV365Tender Authority
Cochin Shipyard Limited ViewPurchaser Address
-Website
http://https://cochinshipyard.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
1.4.3. Check the pressure differential governor of the starting oil pump, in case of sludge in the governor
5
-
-
... More
1.4.4. Check the rotor run out in the thrust bearing
5
-
-
... More
1.4.5 On completing of the service life (10000-12000 hrs), replace the major parts of turbo alternator.
5
-
-
... More
1.4.6. Carry out the inspection / renewal of metal balls of lub oil system shuttle valves/ nr valves. Clean lub oil sump and baffle plates.
5
-
-
... More
1.4.7. Open all units of governing and protection units and remove the sludge. Undertake overhauling/ tuning of all hydraulic and electric control components (local/ remote). Undertake trials as per OEM manual, carryout tuning. Repair and renew as necessary.
5
-
-
... More
1.4.8. Check operation of QCV (Quick Closing Valve). Overhaul the assembly, carryout checks as per OEM manual. Repair/ renew parts/ sub-assemblies as required.
5
-
-
... More
1.4.9. Check operation of GSR (Gland Steam Regulator). Overhaul the assembly, carryout checks as per OEM manual. Repair/ renew parts/ sub-assemblies as required.
5
-
-
... More
1.4.10. Carryout inspection of steam chest nozzle control valve and nozzles for clogging/ clear from obstruction. Overhaul/ repair and renew as per OEM manual, as necessary.
5
-
-
... More
1.4.11. Undertake chemical/ mechanical cleaning of condenser (shell and tube), lub oil cooler (shell and tube) and air ejector (shell and tube). Carryout inspection/ thickness gauging of body. Undertake renewal of doors/ end covers. Replace zinc anodes.
5
-
-
... More
1.4.12. Overhaul complete assembly of feed controller and undertake tuning, as per OEM manual. Repair/ renew as necessary.
5
-
-
... More
1.4.13. Remove the sludge and match clearance values as per OEM document.
5
-
-
... More
1.4.14. In case of sludge in the governor, clean and box back and set value as per OEM manual
5
-
-
... More
1.4.15. Carry out the inspection of spring loaded NR valves
5
-
-
... More
1.4.16. Opening of Air ejector inspection door, measurement of nozzle clearances and inspection of steam piping for leakages/ deterioration and replacement if required.
5
-
-
... More
1.4.18. Application of Belzona 1392 coating on tube sheet of all Six TG condenser.
6
-
-
... More
Cladding - SERVICE COST
-
-
-
... More
1.42.5 Cladding over Steam auxilaiary machineries
1.42.5.1Turbines of Turbo generators
400
-
-
... More
Pumps - SRVICE COST
Overhauling of Pump. Job involves :-
1.45.1 Removal of pumps and degutting of associated system.
1.45.2 Overhauling of Pump, priming unit and motor (for monoblock pumps only) , replacement of worn out components as per opening up inspection. Pressure testing of casing and metal build up if required
1.45.3 Renewal of Mechanical seal
1.45.4 Pressure/ leak test of pump post boxing up. Painting of pump body and foundation with anti corrosive paint primer and top coat. 1.45.5 Fitment of Pump, reftitting associated systems. Renewal of all fasteners (Mat-Al Bronze) and gaskets to be undertaken.
1.46.6 Decoupling and couping with motor/engine and final alignment.
1.46.7 Inspection, renewal of damaged pump stool / foundation.
1.46.8 Inspection, renewal of damaged shock mounts (mounts supplied by yard/Navy).
1.46.9 Carry out performance trial of the pump including parameter checks (suction/ discharge pressure), vibration trials, insulation / SPM checks on motor, motor starting running current checks etc assess for satisfactory performance and defects if any to be rectified.
-
-
-
... More
1.45.44. TG sea water pump- Capacity:220TPH monoblock centrifugal pump
6
-
-
... More
1.45.45. TG condensate pump - Capacity:25 TPH monoblock centrifugal pump
4
-
-
... More
1.45.46. TG starting oil pump- Capacity:17TPH Gear type
4
-
-
... More
1.45.47. TG emergency oil pump - Capacity:01TPH Gear type
3
-
-
... More
Boilers and TD Auxilaries - SERVICE COST
-
-
-
... More
Renewal /Repair of Outer Insulation materials and Cement lagging TD Auxilliaries (TGs)
1
-
-
... More
Turbo Generators - MATERIAL COST
-
-
-
... More
1.4.1.Open all unit of governing and protection unit and remove the sludge.2000 hourly / annual.
5
-
-
... More
1.4.2. Check the condition of the units on which operation comments were made during the preceding operation period.
5
-
-
... More
1.4.3. Check the pressure differential governor of the starting oil pump, in case of sludge in the governor
5
-
-
... More
1.4.4. Check the rotor run out in the thrust bearing
5
-
-
... More
1.4.5 On completing of the service life (10000-12000 hrs), replace the major parts of turbo alternator.
5
-
-
... More
1.4.6. Carry out the inspection / renewal of metal balls of lub oil system shuttle valves/ nr valves. Clean lub oil sump and baffle plates.
5
-
-
... More
1.4.7. Open all units of governing and protection units and remove the sludge. Undertake overhauling/ tuning of all hydraulic and electric control components (local/ remote). Undertake trials as per OEM manual, carryout tuning. Repair and renew as necessary.
5
-
-
... More
1.4.8. Check operation of QCV (Quick Closing Valve). Overhaul the assembly, carryout checks as per OEM manual. Repair/ renew parts/ sub-assemblies as required.
5
-
-
... More
1.4.9. Check operation of GSR (Gland Steam Regulator). Overhaul the assembly, carryout checks as per OEM manual. Repair/ renew parts/ sub-assemblies as required.
5
-
-
... More
1.4.10. Carryout inspection of steam chest nozzle control valve and nozzles for clogging/ clear from obstruction. Overhaul/ repair and renew as per OEM manual, as necessary.
5
-
-
... More
1.4.11. Undertake chemical/ mechanical cleaning of condenser (shell and tube), lub oil cooler (shell and tube) and air ejector (shell and tube). Carryout inspection/ thickness gauging of body. Undertake renewal of doors/ end covers. Replace zinc anodes.
5
-
-
... More
1.4.12. Overhaul complete assembly of feed controller and undertake tuning, as per OEM manual. Repair/ renew as necessary.
5
-
-
... More
1.4.13. Remove the sludge and match clearance values as per OEM document.
5
-
-
... More
1.4.14. In case of sludge in the governor, clean and box back and set value as per OEM manual
5
-
-
... More
1.4.15. Carry out the inspection of spring loaded NR valves
5
-
-
... More
1.4.16. Opening of Air ejector inspection door, measurement of nozzle clearances and inspection of steam piping for leakages/ deterioration and replacement if required.
5
-
-
... More
1.4.18. Application of Belzona 1392 coating on tube sheet of all Six TG condenser.
6
-
-
... More
Cladding - MATERIAL COST
-
-
-
... More
1.42.5 Cladding over Steam auxilaiary machineries
1.42.5.1Turbines of Turbo generators
400
-
-
... More
Pumps - MATERIAL COST
Overhauling of Pump. Job involves :-
1.45.1 Removal of pumps and degutting of associated system.
1.45.2 Overhauling of Pump, priming unit and motor (for monoblock pumps only) , replacement of worn out components as per opening up inspection. Pressure testing of casing and metal build up if required
1.45.3 Renewal of Mechanical seal
1.45.4 Pressure/ leak test of pump post boxing up. Painting of pump body and foundation with anti corrosive paint primer and top coat. 1.45.5 Fitment of Pump, reftitting associated systems. Renewal of all fasteners (Mat-Al Bronze) and gaskets to be undertaken.
1.46.6 Decoupling and couping with motor/engine and final alignment.
1.46.7 Inspection, renewal of damaged pump stool / foundation.
1.46.8 Inspection, renewal of damaged shock mounts (mounts supplied by yard/Navy).
1.46.9 Carry out performance trial of the pump including parameter checks (suction/ discharge pressure), vibration trials, insulation / SPM checks on motor, motor starting running current checks etc assess for satisfactory performance and defects if any to be rectified.
-
-
-
... More
1.45.44. TG sea water pump- Capacity:220TPH monoblock centrifugal pump
6
-
-
... More
1.45.45. TG condensate pump - Capacity:25 TPH monoblock centrifugal pump
4
-
-
... More
1.45.46. TG starting oil pump- Capacity:17TPH Gear type
4
-
-
... More
1.45.47. TG emergency oil pump - Capacity:01TPH Gear type
3
-
-
... More
Boilers and TD Auxilaries - MATERIAL COST
-
-
-
... More
Renewal /Repair of Outer Insulation materials and Cement lagging TD Auxilliaries (TGs)
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements