Cochin International Airport Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 20,00,000Document Cost
₹ 2,500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_CIAL_617929_1Bid Award Id
ViewTender No
CIAL/CIVIL/604/E15Tender Authority
Cochin International Airport Limited ViewPurchaser Address
-Website
http://https://cial.aero/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Drawings 7
Drawings 5
Drawings 8
Drawings 6
Drawings 16
BOQ Items
... More
Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 50 metres and earth filling in the depression/pit-Girth from 600 mm to 900 mm
16
-
-
... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 1000 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed without disturbing existing cables, lines or pipes. All kinds of soil
32690
-
-
... More
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m without disturbing existing cables, lines or pipes.
3732
-
-
... More
Extra for the carriage of surplus excavated earth within a lead of 5.0 km by mehcnaical transport including laoding, unloading, stacking etc. as directed by Engineer-in-Charge
29225
-
-
... More
Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 300 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction
6130
-
-
... More
Providing and Constructing of Embankment with approved material obtained from borrow pits brought from outside with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2 and as per the direction of Engineer in-charge.
1611
-
-
... More
Constructing of subgrade and earthen shoulders with approved material obtained from roadway cutting/departmental supply with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 etc and complete and as per direction of engineer in charge and as per technical specification clause-305 MORTH.
1363
-
-
... More
Providing and Constructing subgrade and earthen shoulders with approved material obtained from borrow pits brought from out side with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 etc and complete and as per direction of engineer in charge and as per technical specification clause-305 MORTH
21364
-
-
... More
Providing and Construction of granular sub-base using graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. Grading-1 - For sub base cum drainage layer Grading 1-Plant Mix Method
5458
-
-
... More
Construction of granular sub-base with available material, graded, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. Grading-1 - For sub base cum drainage layer Grading 1-Plant Mix Method. Material shall be supplied departmentally.
861
-
-
... More
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as directed by Engineer-in-Charge and as per technical specification Clause 406 MORTH.
5922
-
-
... More
Providing and applying Prime Coat with bitumen emulsion on prepared surface of granular Base including cleaning with mechanical broom of road surface and spraying primer at the rate of 0.7 kg/sqm using mechanical means. etc complete and as per direction of Engineer- in -Charge.clause-502 MoRT&H
12901
-
-
... More
Providing and applying Tack Coat with bitumen grade VG-30 (60-70) using pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous/granular surface cleaned with mechanical broom. etc complete and as per direction of Engineer- in-Charge.clause-503 MoRT&H.
80013
-
-
... More
Providing and applying tack coat with bitumen grade VG-30 (60-70) using pressure distributor at the rate of 0.5 kg per sqm on the hungry and dry bituminous surface cleaned with mechanical broom etc as directed by the Engineer incharge.
57918.59
-
-
... More
Providing and laying dense graded bituminous macadam with 100-120 TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder (VG 40) @ 4.25 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects.
7905
-
-
... More
Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder (VG 40) @ 5.4 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 509 complete in all respects - Grading 2 - (13.2 mm Nominal Size)
2546
-
-
... More
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of 6mm metal, filling the joints with fine sand etc. in lines and levels all complete as per the direction of Engineer-in-charge. The area shall be inclusive of cement concrete edge protection.
6536
-
-
... More
Providing and laying 100 mm thick factory made cement concrete interlocking paver block of M - 40 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of 6mm metal, filling the joints with fine sand etc. in lines and levels all complete as per the direction of Engineer-in-charge. The area shall be inclusive of cement concrete edge protection.
9009
-
-
... More
Providing and erecting direction/place identification signs with 10 years warranty,made out of retro reflective sheeting conforming to type XI standards of ASTM D 4956 -09& as per IRC 67-2012 specifications fixed over 2 mm thick aluminium sheet,fixing to the poles and MS frame work. Cost of pole and MS frame work shall be paid separately.
137
-
-
... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. in In gratings, frames, guard bar, ladder, railings, brackets, gates , poles and similar works complete in all respect as directed by engineer in charge
4328
-
-
... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.-On new steel work
124
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade-:Two or more coats on new work
4588
-
-
... More
Providing and fixing reflective road studs ( Raised pavement markers) of ‘category A’ made out of poly carbonate/ABS moulded body and shanks and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromaticity values conforming to ASTM D4280 also confirming to MORTH circular No RW / NH. 33023/10/ 97-DO.III dt 11.06.97 and shall support a load of more than 13 t tested in accordance with ASTM D4280. Lenses shall be moulded of Polycarbonate or methyl methecrylate conforming to ASTM D788 and shall have a CIL not less than values specified in table 1 of said MoRT&H circular including installing by drilling the surface and fixing with adhessive .
3284
-
-
... More
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes complete as directed by Engineer-in-Charge and MORTH Specifications Clause 803
4958
-
-
... More
Providing flexible Spring Posts 900mm htx 80mmdia x200mm base dia including installation using bolts and epoxy including cost of materials,labour charges and conveyance etc complete as directed by engineer in charge
79
-
-
... More
Supplying high density PVC water filled barriers of minimum size: 1000x500x800mm or greater.
25
-
-
... More
Providing and laying precast kerb stone of size 400x150x325mm size, M-20grade concrete in position to the required line, level and curvature joined with cement mortar 1:3 (I cement:3 sand) including making joint with or without groovier (thickens of joints except at sharp curne shall not be more than 5mm) making drainage openings wherever required etc…Complete as per drawing and as directed by Engineer in charge including excavations and PCC for laying. The kerb stone shall have a bottom width of 150mm to top width of 100mm. The top 100mm depth of the kerb shall be tapering from 150mm to 100mm thickness as shown. The kerb shall be fixed over a PCC of M10 grade concrete of 300mm width and 150mm thickness Both sides of the kerb is supplied by PCC of grade M20 75mm thick (triangular section ) as shown.
1574
-
-
... More
Providing and laying in position cement concrete of specified grade including the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
279
-
-
... More
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth level
Thermo - Mechanically Treated bars of grade Fe-500D or more
236965.7
-
-
... More
Extra for laying reinforced cement concrete in or under water and /or liquid mud including cost of pumping or bailling out water and removing slush etc., complete. Note:- The quantity will be calculated by multiplying the depth measured from the subsoil water level upto the centre of gravity of the R.C.C. under subsoil water with the quantity of R.C.C. in cubic metre executed under subsoil water. The depth of centre of gravity shall be reconed correct to 0.1m. 0.05 m or more shall be taken as 0.1 and less than 0.05 m ignored. No extra payment shall be made for placing reinforcement or centering & shuttering under subsoil water conditions.
309
-
-
... More
Providing and laying Non Pressure NP-4 class (heavy- duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2(1 cement : 2 fine sand) including testing of joints etc. complete-450 mm dia RCC pipes.
28.5
-
-
... More
Providing and laying Non Pressure NP-4 class (heavy- duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2(1 cement : 2 fine sand) including testing of joints etc. complete-600 mm dia RCC pipes.
75
-
-
... More
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.
100
-
-
... More
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 110 mm dia PVC pipe with nylon net, extending through the full width of the structure with slope of 1V : 20H towards drawing foce.Complete as per drawing and Technical Specifications
2801
-
-
... More
Construction of subsurface drain with perforated pipe (with geotextile wraping around) of 100 mm internal diameter of PVC, closely jointed, perforations ranging from 3 mm to 6 mm depending upon size of material surrounding the pipe, with 150 mm bedding below the pipe and 300 mm cushion above the pipe, cross section of excavation 450 x 550 mm. Excavated material to be utilised in roadway at site.
4437
-
-
... More
Supplying and stacking of good earth at site (earth measured in stacks will be reduced by 20% for payment)
373
-
-
... More
Mixing & laying of earth and sludge or manure in the required proportion specified or directed by the Emgineer-incharge
70
-
-
... More
Supplying,stacking and laying, spreading aand compacting for sub surface drains with12mm hard broken stone as per the direction of Engineer in charge.(IRC 3.2.1.a)
70
-
-
... More
Supplying,stacking and laying, spreading aand compacting for sub surface drains with 20mm hard broken stone as per the direction of Engineer in charge (IRC 3.2.1.a)
85
-
-
... More
Supplying and Planting grass over the red earth and sand bed closely to get a thick grass lawn suitable for ground in rows of 5cm apart in both direction, keep the area moisture by spraying and sprinkling water till the grass gets sufficient deep roots cutting to level the top surface, trimming and dressing etc. complete as directed by the Engineer-in-Charge. Bermuda Grass
464
-
-
... More
Construction of median and Island above road level with approved material at site,spread, sloped and compacted as per clause 408
294
-
-
... More
Planting flowering plants and shrubs in central verge, median & island
0.52
-
-
... More
Transplantaton of trees within a distance of 2km including excavation around existing trees,pruning of branches,lifting loading and transportation of existing trees,digging pits for placing trees at new place,adding manure,sand,fertilizer,hormones,biofertilizers to it.levelled and neatly dressed and disposal of surplus material from old existing and new sites to designated place. Each tree should be firmly secured to the stake so as to prevent excessive movement, flooding with water,treatment of roots,rope and gunny bags as per the direction of officer in charge.T&P shall be arranged by the contractor and nothing extra shall be paid on this account.Girth of tree shall be measured at a height of 1m above ground level-Girth of trees upto 50cm.
31
-
-
... More
Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811.3
68
-
-
... More
Dismantling of Structures :- Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres
By Mechanical Means for items No. 202 - Cement Concrete Grade M-15 & M-20
17
-
-
... More
Dismantling of sign boards/ advertisment boards of size less than or equal to 3 sqm including excavation and dismantling of foundation concrete , disposal with all lifts and upto a lead of 1000 meters and staking the materials
150
-
-
... More
Scarifying the existing granular road surface to a depth of 50 mm and disposal of scarified material within all lifts and leads upto 1000 metres.
6536
-
-
... More
Rotary boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M-35 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of socketing in hard rock for a depth of not less than 50 cm, using rotary boring pile rig, bentonite solution, disposal of bore muck and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap, etc. all complete, as per specifications & directions of Engineer-in-charge, including removal of excavated earth with all lifts and leads (Length of pile for payment shall be measured upto bottom of pile cap). Minimum cement content shall be 420kg/cum
500 mm dia piles
109
-
-
... More
Construction of bunker (shallow pits or depression, commonly near the green or fairway, that is usually filled with sand.) in the play area complete as per drawing and technical specifications including golf standards as directed by the Engineer in charge. Including earthwork excavation for bunker pit including backfilling of available earth, shaping of bunker area for approx. size of 36 sqm in plan area, earthwork excavation for laying the drainage perforated pipe and placing the 100mm perforated PVC pipe across for drainage and setting up of concrete exit box with sides and cover outside the area for draining out water, backing filling the trench with 12mm coarse aggregate, filling up the bunker with layers of clear available white sand / river sand of approved qulaity and finally edge turfing the bunker lip with bermuda twif dwarf grass around the boundary for smooth finish etc. complete by engaging sufficient labour as directed by the engineer in charge.
1
-
-
... More
Reinforced cement concrete M15 grade Boundary Pillars of standard design as per IRC:25-1967, fixed in position including finishing and lettering but excluding painting complete as directed by Engineer-in-Charge and MORTH Specifications Clause 806
36
-
-
... More
Conducting High strain dynamic load test (Test load 1.5 time the safe capacity (75t) including surface preparation of pile top by removing soil, mud, dust and chipping lean concrete lumps etc and use of coputerised equipment and high skill trained personal for conducting the test, provision for 4.6T hammer, steel helmet, plywood cusion guide frame for testing data analysis and submission of results all complete as per the direction of Engineer in Charge. Routine test (Test Load 1.5 times the Safe capacity)
1
-
-
... More
Supplying high density PVC or LLDPE Traffic cones of height 750 mm and 300 in diameter. They shall be of brilliant red/orange/yellow, ultraviolet stabilized color for maximum visibility and fade resistance under all weather conditions and ambient working temperature.
30
-
-
... More
Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 1000 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.
Ordinary rock
1923
-
-
... More
Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 1000 m.
Ordinary rock
950
-
-
... More
Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.
All kinds of soil
2806
-
-
... More
Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.
Ordinary rock
145
-
-
... More
Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete.
860
-
-
... More
Providing and laying in position machine batched, machine mixed and machine vibrated design mix M-25 grade cement concrete for foundation, footings, plinth beams reinforced cement concrete using cement content as per approved design mix including pumping of concrete to site of laying but, excluding the cost of centering, shuttering, finishing and reinforcement including admixtures in recommended proportion (as per IS 9103) to accelerate,retard setting of concrete to improve workability without impairing strength and durability as per direction of Engineer-in-Charge . Minimum cement content considered in this item is @ 400 kg/cum.
All work upto plinth level
1219
-
-
... More
Centering and shuttering including strutting, etc. and removal of form for:
Foundations, footings, bases of columns, etc for mass concrete
5418
-
-
... More
Centering and shuttering including strutting, etc. and removal of form for:
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
10888
-
-
... More
Centering and shuttering including strutting, etc. and removal of form for:
Lintels, beams, plinth beams, girders bressumers and cantilevers
130
-
-
... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
2728.51
-
-
... More
Centering and shuttering including strutting, etc. and removal of form for:
Suspended floors, roofs, landings, balconies and access platform
186
-
-
... More
Supplying and stacking at site dump manure from approved source, including carriage upto 5 k.m. lead complete (manure measured in stacks will be reduced by 8% for payment) :
Screened through sieve of I.S. designation 20 mm
70
-
-
... More
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M-30 grade conforming to IS 456 or IS 10262 for reinforced cement concrete for foundation,footings,columns,plinth beams,lift pits,sump etc using coarse sand conforming to IS 383 and 20mm nominal size graded hard granite broken stones, excluding the cost of centering, shuttering, finishing and reinforcement including admixtures in proportion of 0.5%of weight of cement (asper IS 9103) to accelerate,retard setting of concrete improve workability without impairing strength and durability as per direction of Engineer-in-Charge. Minimum cement content is 410Kg/m3.- All work upto plinth level
936
-
-
... More
Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material with in all lifts and lead upto 1000 metres by Mechanical Means
445
-
-
... More
Providing and fixing PVC pipes on bottom slab of RCC canal for water percolation complete as per the direction of Engineer-in-Charge. 75 mm pipe 4 kgf/cm2
515
-
-
... More
Centering and shuttering including strutting, etc. and removal of form for:
Edges of slabs and breaks in floors and walls
Above 20 cm wide
69
-
-
... More
Providing and fixing of median marker made of tough, high impact resistant, injection-molded, thermoplastic body having a minimum Notched Izod Impact strength value of 600J/m at room temperature, when tested accordance with ASTM D256 and shall retain at least 70% of this value when subjected to accelerted weathering for 1000hrs as per ASTM G155 or UL 746C. The Median marker shall have, fluorescent yellow color retro-reflective sheeting min 10cmx10cm/10cm dia size with reflectivity values as per IRC:67 and ASTM D4956 type XI specifications , edge protected with no exposed edges to prevent edge lifting, vandalism, sheeting damage, etc. and fixed by a combination of epoxy adhesive and anchoring
1906
-
-
... More
Dismantling manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 1000 metres lead as per direction of Engineer -in-Charge:
Water bound macadam road
8265
-
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:
1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
257
-
-
... More
Supplying and laying HDPE pipe of dia 140mm (PN 10/PE80) in position for cross drainage purpose across road as per as per direction of Engineer -in-Charge:
635
-
-
... More
Dismantling of existing road studs as per the direction of Engineer -in-Charge:
1462
-
-
... More
Filling with available excavated earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.
412
-
-