Calicut University Tender
... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Calicut University Tender
Eprocure
Opening Date12 Jun 2018
Closing Date23 Jun 2018
Tender Amount₹ 29,94,554 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 50,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_UoC_209417_1Bid Award Id
ViewTender No
D3/E-Tender No.06/2018-19Tender Authority
Calicut University ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire.
980
-
188
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 2 x 4 sq. mm + 1 x 4 sq. mm earth wire
44
-
231
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required -4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire.
1266
-
295
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 4 x 4 sq. mm + 2 x 4 sq. mm earth wire
42
-
386
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required - 3 x 2.5 sq. mm.
50
-
103
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 5/6 amps switch.
266
-
115
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 3 pin 5/6 amp socket outlet.
109
-
111
... More
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
284
-
395
... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
77
-
32.9
... More
Supplying and fixing suitable size PVC/GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
4
-
394
... More
Supplying and fixing suitable size PVC/GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
27
-
557
... More
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
935
-
63.1
... More
Supplying and fixing brass batten/ angle holder including connection etc. as required.
251
-
103
... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
461
-
137
... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc.as required.
20
-
144
... More
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required - Upto 450 mm sweep.
33
-
307
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required - Single pole.
245
-
237
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.- Tripple pole.
4
-
961
... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
97
-
9.6
... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required - 40 amps.
13
-
915
... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required - 63 amps.
6
-
931
... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required - 40 amps.
13
-
2925
... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required - 63amps.
6
-
3159
... More
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc.as required.
4
-
1345
... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 6 way (4 + 18), Double door.
4
-
3649
... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 4 way (4 + 12), Double door.
2
-
3017
... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 8 way (4 + 24), Double door.
6
-
4352
... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)- 4 way (4 + 12), Double door.
5
-
6179
... More
Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
10
-
4373
... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
66
-
119
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required - Above 35 sq. mm and upto 95 sq. mm.
40
-
294
... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required - Upto 35 sq. mm (clamped with 1mm thick saddle).
332
-
34.3
... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required -Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp).
20
-
98.8
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 4 X 10 sq. mm (25mm).
15
-
279
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 4 X 16 sq. mm (28mm).
13
-
350
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 3½ x 70 sq. mm (38mm).
2
-
541
... More
Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
1
-
1670
... More
Supplying, 4 core 10 Sq.mm heavy duty PVC/XLPE PVC insulated PVC sheathed AUG Power cable with Aluminium conductor for working voltage upto and including 1100 V conforming to IS 1554 (Part 1 – 1988).
196
-
127
... More
Supplying, 4 core 16sq.mm heavy duty PVC/XLPE insulated PVC sheathed AUG Power cable with Aluminium conductor for working voltage upto and including 1100 V conforming to IS 1554 (Part 1 – 1988).
102
-
152
... More
Supplying, 4 core 25sq.mm heavy duty PVC/XLPE insulated PVC sheathed AUG Power cable with Aluminium conductor of best conductivity aluminium 1.1 KV Grade strictly conforming to IS 1554 (Part 1 – 1964).
70
-
206
... More
Supplying, 3½ core70 Sq.mm heavy duty PVC insulated PVC sheathed AUG Power cable with Aluminium conductor of best conductivity aluminium 1.1 KV Grade strictly conforming to IS 1554 (Part 1 – 1964).
80
-
398
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 4 x 25 sq. mm (28mm).
2
-
354
... More
Supplying and laying No. 10 SWG copper earth wire including end termination by soldering method using suitable size earth lugs, etc complete.
550
-
61
... More
Supplying 1 x 20W tube light (LED) and 1200mm suitable batten for LED tube.
461
-
736
... More
Supplying and fixing LED 5W ordinary lamp.
62
-
180
... More
Supplying and fixing LED 10W ordinary lamp.
172
-
228
... More
Supplying, installing with concrete foundation 300 mm Exhaust fan like, GEC, Bajaj, Usha or equivalent including civil work and giving connection, etc complete.
39
-
2092
... More
Fabricating, supplying and installing MCCB type interior panel board of 415V, 50Hz dust and vermin proof using 16SWG sheet steel construction on angle iron frame work, the board shall be fabricated incorporating incoming and outgoing MCCBs with thermal magnetic release having adjustable OL & SC and of suitable rated ultimate short circuit breaking capacity (Icu = 25/ 35KA) cable entry wire way boxes, bus bars and inter connections are to be done with rigid copper conductors with sleeves and marked with RYB colour including supply and fixing 3Nos. pilot lamp with toggle switch Multi Functional meter and danger notice, and 3 phase digital energy meter and CT’s other identification marks for switches and giving earthing etc complete. The board shall be painted 2 coats of enameled Paint over one coats of metal primer consisting the following. 1) 1No.100A 4 pole MCCB (1 Cu = 35kA) as incomer, 2) 2Nos. 63A 3 pole MCCB (1Cu = 25kA)(As outgoing), 3) 2Nos. 40A 3 pole MCCB (1Cu = 25kA)(As light VDB), 4) 1No. 25A 3 pole MCCB (1Cu = 25kA)(As spare), 5) 1No.200A, 1000mm 50HZ TPN, 415V bus bar chamber with porcelain bus bar supports, 6) 4Nos. 1000 x 32 x 6mm Copper strips with drilled holes for bus bar.
1
-
51728
... More
Fabricating, supplying and installing MCCB type interior panel board of 415V, 50Hz dust and vermin proof using 16SWG sheet steel construction on angle iron frame work, the board shall be fabricated incorporating incoming and outgoing MCCBs with thermal magnetic release having adjustable OL of suitable rated ultimate short circuit breaking capacity (Icu = 25/ 35KA) cable entry wire way boxes, bus bars and inter connections are to be done with rigid copper conductors with sleeves and marked with RYB colour including supply and fixing 3Nos. pilot lamp with toggle switch Multi Functional meter and 3 phase energy meter and danger notice and other identification marks for switches and giving earthing etc complete. The board shall be painted 2 coats of enameled Paint over one coats of metal primer consisting the following, 1) 1No. 63A 3 pole MCCB (1Cu = 25kA)(As incomer), 2) 2Nos. 40A 3 pole MCCB (1Cu = 25kA)(As outgoing), 3) 1No. 25A 3 pole MCCB (1Cu = 25kA)(As spare), 4) 1No.125A, 1000mm 50HZ TPN, 415V bus bar chamber with porcelain bus bar supports, 5) 4Nos. 1000 x 32 x 3mm Copper strips with drilled holes for bus bar.
1
-
37695
... More
Supplying and fixing with concrete foundation 18" heavy duty exhaust fan 450mm, 1400 RPM like Usha, Bajaj, GEC or equivalent including civil work, painting and giving connection complete.
2
-
5886
... More
Dismantling the 1 x 40W / 2 x 40W Fluorescent lamp fixture from the wall/Ceiling and conveying the dismantled materials, which are not required for the work to the electrical store.
240
-
135
... More
Dismantling the damaged wiring installations and its accessories and reinstating the remaining wiring installations on surface the dismantled materials should be returned to the Electrical store.
787
-
36
... More
Dismantling the damaged pedastal mounting main switch board and conveying the dismantled material to the Electrical Store and re-instate the Place painting and cementing etc
4
-
1061
... More
Dismantling the damaged light DB's and VDB,s and reinstate the wall and dismantled materials return to the Electrical Store.
3
-
444
... More
Dismantling the 1400/1200mm AC ceiling fan overhauling greasing and refixing the same on the existing fan hook after repainting with 2 coat of enameled paint over the primer and giving connection using 16/20 flex wire, etc.. complete.
181
-
327
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required - 3 x 1.5 sq. mm .
7
-
68.6
... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) - 8 way (4 + 24), Double door.
1
-
7774
... More
Dismatnling the damaged vertical or horizontal 8 way DB (Copper) and reinstate the cable connection at newly fixed DB and dismantled item return to the Electrical Store.
2
-
540
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required - 6 x 2.5 sq. mm .
2
-
200
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required - 3 x 4 sq. mm .
1
-
152
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required - 6 x 4 sq. mm .
1
-
294
... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230volts, complete as required.
2
-
83
... More
Supplying and fixing 65W LED street light pressure die cast aluminium housing LED street light luminaires with IP 66 on 40mm suitable bended class B GI pipe and necessary length of 1.5 sq.mm 3 core flexible wire for giving connection etc. complete.
4
-
10273
... More
Supplying and fixing following size/ modules, PVC/GI box alongwith modular base & cover plate for modular switches in recess etc as required - 6 Module (200mm X 75mm).
27
-
354
... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required - Group B.
2
-
844
... More
Supplying and fixing following size/ modules, PVC/GI box alongwith modular base & cover plate for modular switches in recess etc as required - 1 or 2 Module (75mm x 75mm).
24
-
240
... More
Supplying and fixing following size/ modules, PVC/GI box alongwith modular base & cover plate for modular switches in recess etc as required - 3 Module (100mm x 75mm).
2
-
254
... More
Dismantling the damaged horizontal 8 way DB (Open) and re-instate the all connections at the newly fixed DB and dismantled items to return to the Store (including all re-arrangement in the dismantled area).
4
-
1080
... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 2 + 12 way / 14 way, Double door.
4
-
1580
... More
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required - 40 amps .
4
-
305
... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required - 40 amps.
4
-
2359
... More
Dismantling the damaged single phase DB,s and reinstate the connections and newly fixed DB and dismantled item return to the Store (Clamping the existing conduit if needed).
4
-
265
... More
Supplying and fixing following size/ modules, PVC/GI box alongwith modular base & cover plate for modular switches in recess etc as required -8 Module (125mm X 125mm).
55
-
408
... More
Dismantling the damaged Switch Board to the rooms and verandah and reconnect the connections at newly fixed switch Board and return the dismantled material in the Store. (Also clamping the conduit if needed) .
55
-
168
... More
Supplying, 4 core 6sq.mm heavy duty insulated PVC sheathed AUG Power cable Aluminium conductor for working voltage upto and including 1100 V conforming to IS 1554 (Part 1 – 1988).
15
-
118
... More
Cable gland termination of 4 core 6sq.mm PVC AUG cable using nickel plated gland, Aluminium crimping socket with necessary earthing using No.10 SWG copper and copper clips etc..
5
-
382
... More
Cable gland termination of 4 core 4sq.mm PVC AUG cable using nickel plated gland Aluminium crimping socket with necessary earthing using No.10 SWG copper and copper clips etc..
1
-
343
... More
Supplying, 4 core 4sq.mm heavy duty PVC/XLPE insulated PVC sheathed AUG Power cable with Aluminium conductor for working voltage upto and including 1100 V conforming to IS 1554 (Part 1 – 1988).
2
-
100
... More
Fabricating, supplying and installing MCCB type interior panel board of 415V, 50Hz dust and vermin proof using 16SWG sheet steel construction on angle iron frame work, the board shall be fabricated incorporating incoming and outgoing MCCBs with thermal magnetic release having adjustable OL of suitable rated ultimate short circuit breaking capacity (Icu = 25/ 35KA) cable entry wire way boxes, bus bars and inter connections are to be done with rigid copper conductors with sleeves and marked with RYB colour including supply and fixing 3Nos. pilot lamp with toggle switch Multi Functional meter and danger notice and CT,s other identification marks for switches and giving earthing etc complete. The board shall be painted 2 coats of enameled Paint over one coats of metal primer consisting the following. 1) 1No. 100A 4 pole MCCB (1Cu = 35kA)(As incomer), 2) 5Nos. 32A 3 pole MCCB (1Cu = 25kA)(As outgoing), 3) 1No.200A, 1000mm 50HZ TPN, 415V bus bar chamber with porcelain bus bar supports, 4) 4 Nos. 1000 x 32 x 3mm copper strips with drilled holes for bus bar.
1
-
50568
... More
Supplying and fixing in the existing Panel Board base mount Electronic type 3 phase 4 core CT operated 240V 5 to 10A/ 20A energy meter.
1
-
3864
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements