Calicut University Tender

... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Calicut University Tender

Works
Eprocure
Opening Date12 Jun 2018
Closing Date23 Jun 2018
Tender Amount₹ 57,00,425 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire.

500

-

154

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire.

3000

-

188

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 2 x 4 sq. mm + 1 x 4 sq. mm earth wire.

900

-

231

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required -4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire.

1500

-

295

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required -4 x 4 sq. mm + 2 x 4 sq. mm earth wire.

750

-

386

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required - 1 x 1.5 sq. mm .

100

-

31.5

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required - 3 x 1.5 sq. mm.

300

-

68.6

... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required -3 x 2.5 sq. mm.

500

-

103

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required - 20 mm.

200

-

78.2

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 5/6 amps switch.

75

-

115

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 3 pin 5/6 amp socket outlet.

75

-

111

... More
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

450

-

395

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

250

-

32.9

... More
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required - 6 Module (200mm X 75mm).

75

-

354

... More
Supplying and fixing following size/ modules, PVC/GI box alongwith modular base & cover plate for modular switches in recess etc as required - 8 Module (125mm X 125mm).

30

-

408

... More
Supplying and fixing following size/ modules, PVC/GI box alongwith modular base & cover plate for modular switches in recess etc as required - 12 Module (200mm x 150mm).

20

-

472

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

250

-

430

... More
Supplying and fixing suitable size PVC/GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

250

-

557

... More
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.

800

-

63.1

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/ 6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).

100

-

692

... More
Supplying and fixing PVC batten/ angle holder including connections etc. as required.

100

-

85

... More
Supplying and fixing 20W, 1200mm LED Tube with batten – 6500K (4 feet) and giving connection etc. complete.

400

-

737

... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

400

-

339

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.

100

-

144

... More
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored).

50

-

34.3

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator) -12 way, Double door.

30

-

1580

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) - 4 way (4 + 12), Double door.

30

-

6179

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) - 8 way (4 + 24), Double door.

25

-

7774

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) - 12 way (4 + 36), Double door.

15

-

9867

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required - Single pole.

500

-

237

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.- Triple pole.

90

-

961

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

250

-

9.6

... More
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required - 40 amps.

30

-

305

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required - 40 amps.

30

-

915

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required - 63 amps.

40

-

931

... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required - 25 amps.

25

-

2265

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required - 40 amps.

25

-

2925

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required - 63 amps.

40

-

3159

... More
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required.

20

-

861

... More
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A, 415 V “C” curve TP MCB complete with connections, testing and commissioning etc. as required.

25

-

1205

... More
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

25

-

1345

... More
Supplying, 4 core 10 Sq.mm heavy duty PVC/XLPE PVC insulated PVC sheathed AUG Power cable with Aluminium conductor for working voltage upto and including 1100 V conforming to IS 1554 (Part 1 – 1988).

750

-

127

... More
Supplying, 4 core 16sq.mm heavy duty PVC/XLPE insulated PVC sheathed AUG Power cable with Aluminium conductor for working voltage upto and including 1100 V conforming to IS 1554 (Part 1 – 1988).

650

-

152

... More
Supplying, 4 core 25sq.mm heavy duty PVC/XLPE insulated PVC sheathed AUG Power cable with Aluminium conductor of best conductivity aluminium 1.1 KV Grade strictly conforming to IS 1554 (Part 1 – 1964).

400

-

206

... More
Supplying, 3½ core 35 Sq.mm heavy duty PVC/XLPE insulated PVC sheathed AUG Power cable with Aluminium conductor of best conductivity aluminium 1.1 KV Grade strictly conforming to IS 1554 (Part 1 – 1964).

200

-

230

... More
Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required - 100 mm width X 50 mm depth X 1.6 mm thickness.

150

-

829

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required - Upto 35 sq. mm (clamped with 1mm thick saddle).

1000

-

34.3

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. - Upto 35 sq. mm (clamped with 1mm thick saddle).

150

-

28.8

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 4 x 10 sq. mm (25mm).

60

-

279

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 4 X 16 sq. mm (28mm).

50

-

350

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required - 4 X 25 sq. mm (28mm).

30

-

354

... More
Supplying and laying No. 10 SWG copper earth wire including end termination by soldering method using suitable size earth lugs, etc complete.

900

-

61

... More
Dismantling the 1 x 40W / 2 x 40W Fluorescent lamp fixture from the wall/Ceiling and conveying the dismantled materials, which are not required for the work to the electrical store.

400

-

135

... More
Dismantling the damaged wiring installations and its accessories and reinstating the remaining wiring installations on surface the dismantled materials should be returned to the Electrical store.

1000

-

36

... More
Supply and fixing 415V 4 pole 40Amps. Capacity miniature type isolator with company makes suitable metal case enclosure and giving connection in concealed system and colour wash. Etc. complete.

20

-

1634

... More
Dismantling the existing damaged pedestal type switch board consisting switches cable entry box incoming and outgoing cable gland termination earthing etc. without causing any damage to the healthy parts and plastering the floor/wall wherever necessary and including the conveying the dismantled materials to the electrical store.

10

-

649

... More
Fabricating, supply and installing MCCB type interior panel board of 415V, 50Hz dust and vermin proof using 16SWG sheet steel construction on angle iron frame work, the board shall be fabricated incorporating incoming and outgoing MCCBs with thermal magnetic release having adjustable OL & SC and of suitable rated ultimate short circuit breaking capacity (Icu = 16/25/ 35kA) cable entry wire way boxes, bus bars and inter connections are to be done with rigid copper conductors with sleeves and marked with RYB colour including supply and fixing 3Nos. pilot lamp with toggle switch MF meter (V,A,PF etc.) base mount 3 phase energy meter with CT, danger notice identification marks for switches and giving earthing etc complete. The board shall be painted 2 coats of enameled Paint over one coats of metal primer consisting the following: 1) 1No. 160A 4 pole MCCB (Icu = 35kA) as incomer, 2) 4 Nos. 63A 3 pole MCCB (Icu=25kA) as outgoing, 3)1 No. 40A 3 pole MCCB (Icu=25kA) as outgoing, 4) 1No. 25A 3 pole MCCB (Icu=25kA) outgoing, 5) 1No. 300A TPN, 415V copper bus bar supporting on SMC insulators with heat shrinking RYB coloured sleeves.

5

-

67248

... More
Fabricating, supply and installing MCCB type interior panel board of 415V, 50Hz dust and vermin proof using 16SWG sheet steel construction on angle iron frame work, the board shall be fabricated incorporating incoming and outgoing MCCBs with thermal magnetic release having adjustable OL & SC and of suitable rated ultimate short circuit breaking capacity (Icu = 16/25/ 35kA) cable entry wire way boxes, bus bars and inter connections are to be done with rigid copper conductors with sleeves and marked with RYB colour including supply and fixing 3Nos. pilot lamp with toggle switch MF meter (V,A,PF etc.) base mount 3 phase energy meter with CT, danger notice identification marks for switches and giving earthing etc complete. The board shall be painted 2 coats of enameled Paint over one coats of metal primer consisting the following: 1) 1No. 125A 4 pole MCCB (Icu = 35kA) as incomer, 2) 2 Nos. 63A 3 pole MCCB (Icu=25kA) as outgoing, 3) 3 Nos. 40A 3 pole MCCB (Icu=25kA) as outgoing, 4) 1No. 200A TPN, 415V copper bus bar supporting on SMC insulators with heat shrinking RYB coloured sleeves.

3

-

53399

... More
Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.

10

-

4373

... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc as required.

5

-

958

... More
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.

750

-

119



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.