Calicut University Tender
... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Calicut University Tender
Eprocure
Opening Date19 Jun 2019
Closing Date28 Jun 2019
Tender Amount₹ 5,48,678 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 13,717Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_UoC_282313_1Bid Award Id
ViewTender No
D3/E-Tender No.03/2019-20Tender Authority
Calicut University ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Wiring plug point along with wiring of light point including supply and fixing 5A flush type modular switch and 3 pin plug socket in combined possition
7
-
422
... More
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
1
-
1110
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.
62
-
154
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
124
-
188
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required -2 X 4 sq. mm + 1 X 4 sq. mm earth wire
72
-
231
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire.
44
-
295
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
30
-
386
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
5
-
542
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required - 3 x 1.5 sq. mm.
15
-
68.6
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required - 3 x 2.5 sq. mm.
15
-
103
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required - 3 x 4 sq. mm.
20
-
108
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required - 3 x 6 sq. mm.
20
-
222
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 3 pin 5/6 A socket outlet.
13
-
111
... More
Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in recess etc. as required - 1 or 2 Module (75 mmX75 mm).
13
-
240
... More
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
55
-
63
... More
Supplying and fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required..
2
-
557
... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/ 6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
7
-
692
... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) - 4 way (4 + 12), Double door.
1
-
3017
... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) - 4 way (4 + 12), Double door.
1
-
6179
... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 8 way, Double door.
1
-
1456
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Single pole.
19
-
237
... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
6
-
9.6
... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required - Triple pole.
1
-
961
... More
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required - 40 A.
1
-
305
... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required - 25 A.
1
-
2265
... More
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required - 40A.
1
-
915
... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required - 25A
1
-
2877
... More
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required - 100A.
1
-
1179
... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required - 63A
1
-
3159
... More
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/ 32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
3
-
861
... More
Supplying, 4 core 25sq.mm heavy duty PVC/XLPE insulated PVC sheathed AUG Power cable with Aluminium conductor of best conductivity aluminium 1.1 KV Grade strictly conforming to IS 1554 (Part 1 – 1964).
20
-
206
... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required - Upto 35 sq. mm (clamped with 1mm thick saddle).
18
-
34.3
... More
Supplying and laying No. 10 SWG copper earth wire including end termination by soldering method using suitable size earth lugs, etc complete,
25
-
61
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 4 X 25 sq. mm (28mm).
2
-
354
... More
Supplying, installing with concrete foundation 300 mm Exhaust fan like, GEC, Bajaj, Usha or equivalent including civil work and giving connection, etc complete.
3
-
2092
... More
Conveying and fixing 1200/1400 mm AC Ceiling fan including supplying and fixing fan hook and giving connection using necessary length of 3 core flexible wire of size 16/0.20, etc.. complete.
2
-
420
... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
16
-
144
... More
Supplying and fixing extra down rod of 10 cm length G.I. pipe,15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored).
10
-
30
... More
Supplying and fixing DP steel enclosure on surface/recess alongwith 25/32A. 240V DP Isolator complete with connections, testing and commissioning etc as required.
2
-
603
... More
Supply and fixing 20W 1200mm Tube with LED batten 6500K (4 feet) and giving connection etc. complete..
34
-
483
... More
Supplying and fixing 3 phase 4 wire electronics energy meter on a suitable size weather proof box giving connection etc complete.
1
-
3147
... More
Supply and installing 400 mm AC sweep AC oscillating type wall mounting fan (Bajaj, Usha, Crompton or equivalent) with suitable bolt and nut and giving connection etc complete.
10
-
1993
... More
Supplying and fixing 10W LED Bulk Head fittings.
3
-
697
... More
Supply and installation of 50W LED Street light with related accessories.
4
-
3523
... More
Supplying and fixing 18W LED, recess mounted round shaped down lighter suitable for low ceiling heights, ceiling should be cut in required shape and make good connection etc complete.
12
-
1426
... More
Supplying 3.5 core 240sq.mm heavy duty PVC insulated PVC sheathed AUG power cable with aluminium conductor of best conductivity aluminium 1.1KV Grade strictly confirming to IS.
59
-
1426
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required - Above 185 sq. mm and upto 400 sq. mm.
55
-
340
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required - Above 185 sq. mm and upto 400 sq. mm.
20
-
89.2
... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. - Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp).
10
-
165
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 3½ X 240 sq. mm (62mm).
2
-
1357
... More
Supplying, 3½ core70 Sq.mm heavy duty PVC insulated PVC sheathed AUG Power cable with Aluminium conductor of best conductivity aluminium 1.1 KV Grade strictly conforming to IS 1554 (Part 1 – 1964).
10
-
398
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required -3½ X 70 sq. mm (38mm)).
2
-
541
... More
Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
3
-
4373
... More
Supplying and installing No. 8 SWG copper earth wire including end termination of soldering method using suitable size earth socket, soldering led etc…
30
-
91
... More
Supplying and fixing 150mm GI pipe (medium clas) using necessary clamps for protection of UG cable drops in the LT pole or building wall.
5
-
1678
... More
Supplying and making outdoor cable end termination with heat shrinkable joining kit complete with all accessories including lugs suitable for size of 3.5 core x 185 sq.mm XLPE aluminium conductor cable etc complete.
1
-
4800
... More
Replacement of meters with RYB indication lamps and repainting of existing panel board the dismantled materilas shoul be return to the electrical store.
1
-
5754
... More
Supplying and laying l50mm GI pipe (medium class) in the existing cable trench.
18
-
1662
... More
Supplying and making outdoor cabler end termination with heat shrinkable joining kit complete with all accessories including lugs suitable for size of 3.5 core x 240 sq.mm XLPE aluminium conductor cable etc complete.
1
-
5207
... More
Supplying and intalling 3Nos. of 300A Kit Kat Fuse Unit (Lug type) using suitable size metal box on LT post with suitable size clamps, bolts, nuts neutral link etc completed.
1
-
5860
... More
Fabricating, supplying and installing MCCB type interior panel board of 415V, 50Hz dust and vermin proof using 16SWG sheet steel construction on angle iron frame work, the board shall be fabricated incorporating incoming and outgoing MCCBs with thermal magnetic release having adjustable OL & SC and of suitable rated ultimate short circuit breaking capacity (Icu = 25/ 35/50kA) cable entry wire way boxes, bus bars and inter connections are to be done with rigid copper conductors with sleeves and marked with RYB colour including supply and fixing 3Nos. pilot lamp with toggle switch, MFmeter V,A, PF etc. base mount 3 phase pilot lamp with indicator. The board shall be painted 2 coats of enameled Paint over one coats of metal primer consisting the following.1) 1No.250A 4 pole MCCB as incomer., 2) 4Nos. 100A 4 pole MCCB (As outgoing).
1
-
75821
... More
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
10
-
457
... More
Supplying, 3½ core185 Sq.mm heavy duty PVC insulated PVC sheathed AUG Power cable with Aluminium conductor of best conductivity aluminium 1.1 KV Grade strictly conforming to IS 1554 (Part 1 – 1964).
2
-
887
Evaluation Notes How It Works ?
Potential Partner