Calicut University Tender
... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Calicut University Tender
Eprocure
Opening Date5 Nov 2018
Closing Date14 Nov 2018
Tender Amount₹ 6,93,293 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 18,637Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_UoC_246988_1Bid Award Id
ViewTender No
D3/E-Tender No.27/2018-19Tender Authority
Calicut University ViewPurchaser Address
-Website
http://etenders.kerala.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire.
206.5
-
154
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire.
185.5
-
188
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required -4 X 4 sq. mm + 2 X 4 sq. mm earth wire.
295
-
386
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required - 4 X 6 sq. mm + 2 X 6 sq. mm earth wire.
10
-
542
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required -4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire.
80
-
295
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required - 2 x 1.5 sq. mm.
40
-
50.7
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required - 3 x 1.5 sq. mm.
40
-
68.6
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm.
20
-
103
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required - 3 x 4 sq. mm.
30
-
152
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required - 3 x 6 sq. mm.
10
-
222
... More
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required - 6 x 1.5 sq. mm.
12
-
132
... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
30
-
32.9
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 5/6 amps switch.
12
-
115
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 15/16 A switch.
6
-
156
... More
Supplying and fixing following size/ modules, PVC/GI box alongwith modular base & cover plate for modular switches in recess etc as required - 3 Module (100 mmX75 mm).
4
-
254
... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required - 3 pin 5/6 amp socket outlet.
12
-
111
... More
Supplying and fixing following size/ modules, PVC/GI box alongwith modular base & cover plate for modular switches in recess etc as required - 6 Module (200mm x 75mm).
9
-
354
... More
Supplying and fixing following size/ modules, PVC/GI box alongwith modular base & cover plate for modular switches in recess etc as required - 1 or 2 Module (75 mm x 75 mm).
20
-
240
... More
Supplying and fixing brass batten/ angle holder including connection etc. as required.
5
-
103
... More
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junctionbox/ wooden block including connection etc as required.
84
-
63.1
... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
5
-
137
... More
Supplying and fixing extra conduit down rod of 20 cm length GI pipe 15mm dia. Heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
20
-
34.3
... More
Installation, testing and commissioning of ceiling fan, including the down rods of standard length (upto 30 cm) with 1.5 sq. mm. FRLS PVC insulated, copper conductor, single core cable etc. as required.
3
-
144
... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, identification marks, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) - 12 way, Double door.
1
-
1580
... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, identification marks earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) - 4 way (4 + 12), Double door.
2
-
3017
... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, identification marks, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) - 4 way (4 + 12), Double door.
2
-
6179
... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, identification marks, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) - 8 way (4 + 24), Double door.
2
-
7774
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required - Single pole.
9
-
237
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required -Triple pole.
10
-
961
... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
30
-
9.6
... More
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required - 40 A.
1
-
305
... More
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required - 40A.
2
-
915
... More
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required - 100A.
2
-
1179
... More
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required - 63A.
1
-
931
... More
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required - 25 A.
1
-
2265
... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required -40 amps.
2
-
2925
... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required -63 amps.
1
-
3159
... More
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
1
-
861
... More
Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A, 415 V “C” curve TP MCB complete with connections, testing and commissioning etc. as required.
1
-
1205
... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required- Upto 35 sq. mm (clamped with 1mm thick saddle).
40
-
34.3
... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required-Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) .
44
-
98.8
... More
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required- Above 95 sq. mm and upto 185 sq. mm (clamped with 25/ 40x3mm MS flat clamp).
80
-
115
... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required - Above 95 sq. mm and upto 185 sq. mm (clamped with 25/ 40x3mm MS flat clamp).
80
-
83.7
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 4 X 16 sq. mm (28mm). (9.1.33)
2
-
350
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required- 3½ X 35 sq. mm (32mm).
2
-
387
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required- 3½ X 50 sq. mm (35 mm).
2
-
486
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required- 3½ X 70 sq. mm (38mm).
4
-
541
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required- 3½ X 120 sq. mm (45 mm).
2
-
686
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required- 3½ X 150 sq. mm (50 mm).
2
-
813
... More
Supplying, 4 core 16sq.mm heavy duty PVC/XLPE insulated PVC sheathed AUG Power cable with Aluminium conductor for working voltage upto and including 1100 V conforming to IS 1554 (Part 1 – 1988).
32
-
152
... More
Supplying, 3½ core 35 Sq.mm heavy duty PVC/XLPE insulated PVC sheathed AUG Power cable with Aluminium conductor of best conductivity aluminium 1.1 KV Grade strictly conforming to IS 1554 (Part 1 – 1964).
15
-
230
... More
Supplying, 3½ core 50sq.mm heavy duty PVC insulated PVC sheathed AUG Power cable with Aluminium conductor of best conductivity aluminium 1.1 KV Grade strictly conforming to IS 1554 (Part 1 – 1964).
8
-
304
... More
Supplying, 3½ core70 Sq.mm heavy duty PVC insulated PVC sheathed AUG Power cable with Aluminium conductor of best conductivity aluminium 1.1 KV Grade strictly conforming to IS 1554 (Part 1 – 1964).
61
-
398
... More
Supplying, 3½ core120 Sq.mm heavy duty PVC insulated PVC sheathed AUG Power cable with Aluminium conductor of best conductivity aluminium 1.1 KV Grade strictly conforming to IS 1554 (Part 1 – 1964).
80
-
618
... More
Supplying, 3½ core150 Sq.mm heavy duty PVC insulated PVC sheathed AUG Power cable with Aluminium conductor of best conductivity aluminium 1.1 KV Grade strictly conforming to IS 1554 (Part 1 – 1964).
10
-
716
... More
Supplying and installing No. 8 SWG copper earth wire including end termination of soldering method using suitable size earth socket, soldering led etc…
190
-
91
... More
Supplying and laying No. 10 SWG copper earth wire including end termination by soldering method using suitable size earth lugs, etc complete.
220
-
61
... More
Supply and installing 400 mm AC sweep AC oscillating type wall mounting fan (Bajaj, Usha, Crompton or equivalent) with suitable bolt and nut and giving connection etc complete.
16
-
1993
... More
Supplying and fixing 18W LED, recess mounted round shaped down lighter suitable for low ceiling heights, ceiling should be cut in required shape and make good connection etc complete.
83
-
1426
... More
Supplying, installing with concrete foundation 300 mm Exhaust fan like, GEC, Bajaj, Usha or equivalent including civil work and giving connection, etc complete.
4
-
2092
... More
Supplying and fixing 4 pole 40A capacity, miniature type Isolator with company make suitable metal case enclosure and giving connection in open conduit system etc. completed.
10
-
1371
... More
Supplying and laying 2m x 1m x 12mm Electrical Grade rubber mat.
1
-
2171
... More
Fabricating, supply and installing MCCB type interior panel board of 415V, 50Hz dust and vermin proof using 16SWG sheet steel construction on angle iron frame work, the board shall be fabricated incorporating incoming and outgoing MCCBs with thermal magnetic release having adjustable OL & SC and of suitable rated ultimate short circuit breaking capacity (Icu = 16/25/ 35kA) cable entry wire way boxes, bus bars and inter connections are to be done with rigid copper conductors with sleeves and marked with RYB colour including supply and fixing 3Nos. pilot lamp with toggle switch MF meter (V,A, F,PF etc.) panel mount 3 phase energy meter with CT, danger notice board, rortating handle bar, identification marks for switches, spreaders for all MCCBs and giving earthing etc complete. The board shall be painted 2 coats of enameled Paint over one coats of metal primer consisting the following: 1) 1No. 160A 4 pole MCCB (Icu = 35kA) as incomer, 2) 2 Nos. 100 A 4 pole MCCB (Icu=25kA) as outgoing, 3) 2 Nos. 40A 4 pole MCCB (Icu=25kA) as outgoing, 4) 1 Nos. 63 A 4 pole MCCB (Icu=25kA) as outgoing, 5) 4Nos. 180A TPN 50Hz (25 x 6 x 1200mm ) x 4 copper 415V bus bar supporting on SMC insulators with heat shrinking RYB coloured sleeves.
1
-
56798
Evaluation Notes How It Works ?
Potential Partner