Border Security Force Tender
... More
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 63,346Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_BSF_851704_1Tender No
09/EE(E)/FTR OD/BGLR/BSF/2024-25Tender Authority
Border Security Force ViewPurchaser Address
-Website
http://http://bsf.nic.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
SITC of residential substation energy meter and laying of LT XLPE cable for 82 Nos residential quarters of 88 BN Now 159 Bn BSF under SHQ BSF Chennai Sub Head I Provision of Domestic Substation for residential quarters
SITC of residential substation energy meter and laying of LT XLPE cable for 82 Nos residential quarters of 88 BN Now 159 Bn BSF under SHQ BSF Chennai Sub Head I Provision of Domestic Substation for residential quarters
BOQ Items
... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I nut, bolt, spring, washer excavation and re-filling etc. as required.
25
-
-
... More
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
25
-
-
... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
25
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Above 95 sq. mm and upto 185 sq. mm
581
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Above 185 sq. mm and upto 400 sq. mm
160
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METALpipe as required.Above 95 sq. mm and upto 185 sq. mm
591
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METALpipe as required.Above 185 sq. mm and upto 400 sq. mm
175
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 95 sq. mm and upto 185 sq. mm
10
-
-
... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Above 185 sq. mm and upto 400 sq. mm
10
-
-
... More
Supplying and making cable route marker with cement concrete 1:2:4 (1cememt : 2 Course Sand : 4 Graded stone aggregate 20mm nominal size)size of 60cm X 60cm at The bottom and 50cm X 50cm at the top with a thickness of 10cm including inscription duly engraved as required
30
-
-
... More
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 11KV grade of following size direct in ground including excavation. Sand cushioning, protective covering and refiling the trench etc as required. Above 120 sq. mm and upto 400 sq. mm
20
-
-
... More
Laying of one number PVC Insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Above 120 sq. mm and upto 400 sq. mm
20
-
-
... More
Laying of one number PVC Insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing mesonry open duct as required.Above 120 sq. mm and upto 400 sq. mm
5
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 185 sq. mm (57mm)
2
-
-
... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 240 sq. mm (62mm)
4
-
-
... More
Supplying and making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.300 sq.mm
1
-
-
... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.300 sq.mm
1
-
-
... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part Il complete with fitting and cutting. jointing etc. in the existing trench, complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal).
591
-
-
... More
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part Il complete with fitting and cutting. jointing etc. in the existing trench, complete as required. 120 mm dia (OD-120 mm & ID-103 mm nominal)
190
-
-
... More
Supplying and Laying of 100 mm size "C" Class G.Ipipe direct in ground including cutting the Bitumen road ( width 30 cm & depth of 40 cm ), and refilling the road etc as required.
60
-
-
... More
SITC of floor mounted free standing outdoor type weather and vermin proof feeder pillar approx .800mmx 900mm x 500 mm) fabricated from 2mm thick MS/CRCA sheet with hinged double leaf shutters with pad locking arrangement (Front & Backside) handle gaskets etc. with sloped roof with ventilation louvers and brass inscet screen wire mesh at ends,75 mm x 40 mm ISLC channel base frame, detachable gland plates etc. including painting with one or more coats of epoxy primer and two or more coats of epoxy paint of approved colour, earthing the body with 32 mm x 5 mm Gl earth strip to the entire with of the board. The feeder pillar shall be instalied on suitable size C- shaped foundation of 1.3:6 (1 cement, coarse sand: 6 graded stone aggregate 40 mmnominal) up to 30 cm height from ground level and confirming to CPWD genaral specifications Part-II (external), Part-IV (Sub-station) as amended up to date including providing and fixing fotiowing switchgears, interconnection with suitable size busbar etc. as requires. a) 400 Amps. 36KV (ics=100% icu), 415 Volts, 50Hz, 4 pole MCCB with microprocessor based current, short circuit release, extended rotary handle etc. 01 No. b) Load monitor of class 1.0 accuracy with RS 485 communication capability and with suitably rated CT's of 16 VA, 15P 10 accuracy for protection giving 3 phase display of different parameter like voltage. current, power, power factor, frequency, active power, reactive power, total power, energy. Maximum Demand etc-1 No
c) 3 Nos. Phase indicating LED lamps with 6A SP MCB protection - 1Set.
Out door Feeder Pilar as above.
1
-
-
... More
Supplying Installation Testing Commissioning of 160KVA 110.415 KV. 3 Phase, 50Hz, Dyn11 vector group, copper wound. Outdoor ONAN type Transformer with off load tap switch of rating +5% to 7.5% steps of 2.5% on HV. side cable end boxes on HV side suitable for 3x300sqm XLPE cable of 11KV grade and 1 Nos 3.5 x 240 sq.mm XLPE cable of 1.1KV grade on LV side complete with all accessories including first filling of filtered dehydrated oil and confirming to IS 2026 (Part 1 to 5) & as per specification etc. including neutral CT in brought out neutral for low set standby earth fault relay unit etc. as required. Transformer total losses shall| be as per Table-2 Energy Efficiency Star-2 of IS 1180 Part-1: 2014 (Losses Not more than 955 W at 50% load and 2750 W at 100% load). % Impedance and Temp Rise of Oil Winding and shall be as per IS 1180 Part- 1 2014 (The transformer shall be installed on the existing cement concrete floor foundation as required)- Make of transformer ABB/Kirloskar/Crompton/Greaves/Siemens/ Servokon.Transformer as above.
1
-
-
... More
Supplying of 11 KV(earthed) XLPE insulated screened with extruded semi conducting compound in combination with copper tape, cores laidup, inner sheath of PVC tape, galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS 7098/11/1985 with latest amendment of following size etc., as required. Size 3 x 300 Sq.mm of Finolex/L&T/Polycab/Havella/KEI make.
30
-
-
... More
Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
4.21
-
-
... More
Providing and laying in position cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of Transformer / feeder pillar etc including form work etc as required.
4.51
-
-
... More
Supplying and fixing of the following items in the existing panels including replacement of the damaged items, fixing new items, terminations, credit for the old dismantled items etc complete as required.125A 4 Pole MCCB.
2
-
-
... More
Supplying and fixing of the following items in the existing panels including replacement of the damaged items, fixing new items, terminations, credit for the old dismantled items etc complete as required.63A 4 Pole MCCB.
1
-
-
... More
Supplying and fixing of the following items in the existing panels including replacement of the damaged items, fixing new items, terminations, credit for the old dismantled items etc complete as required.Multi function meter.
1
-
-
... More
Supplying and fixing of the following items in the existing panels including replacement of the damaged items, fixing new items, terminations, credit for the old dismantled items etc complete as required.63A 4 Pole SFU.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%