Bharat Sanchar Nigam Limited Tender

Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.

Bharat Sanchar Nigam Limited - BSNL Tender

Works
Civil And Construction
Excavation
Consultancy Services
Eprocure
Opening Date30 Oct 2024
Closing Date12 Nov 2024
Tender Amount₹ 8,01,540 
Notes
Download

Costs

Summary

Shifting Of Ea Sets At Various Sites Under Malappuram Ba For Re Dimensioning Optimizationvacating Of Site

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Above 63 KVA upto 100 KVA

3

-

-

... More
Above 100 KVA upto 250 KVA

1

-

-

... More
Dismantling the following capacity canopy / non canopy type RTU AMF/ non AMF EA set after removing all electrical and mechanical connection such as Neutral / body earthing silencer piping, fuel line connection, cable connection etc as reqd.

-

-

-

... More
Upto 30 KVA Capacity

4

-

-

... More
Above 30 KVA upto 63 KVA Capacity

4

-

-

... More
Above 63 KVA upto 100 KVA

1

-

-

... More
Shifting the EA set and all other dismantled associated item [any as per available along with the EA set at site], arranging suitable vehicle, loading in vehicle, transporting to the proposed station within 20 Kms, unloading the EA set at destination site etc as required.

-

-

-

... More
Upto 30 KVA Capacity conventional type/Canopy / RTU type

8

-

-

... More
Above 30 KVA upto 63 KVA Capacity conventional type/Canopy / RTU type

8

-

-

... More
Above 63 KVA upto 100 KVA conventional type/Canopy / RTU type

4

-

-

... More
Above 100 KVA upto 250 KVA conventional type/Canopy / RTU type

1

-

-

... More
Extra charge for transportation kilometers above the 20 Kms ( for excess kilometers only as specified in item -3)for conventional / canopy type of following capacity etc as reqd.

-

-

-

... More
Upto 30 KVA Capacity conventional type/Canopy / RTU type

150

-

-

... More
Above 30 KVA upto 63 KVA Capacity conventional type/Canopy / RTU type

100

-

-

... More
Above 63 KVA upto 100 KVA conventional type/Canopy / RTU type

50

-

-

... More
Above 100 KVA upto 250 KVA conventional type/Canopy / RTU type

50

-

-

... More
Leading and positioning the conventionl type EA sets of following capacity on the existing plinth/ room at ground floor , installing the EA set, including its associated items like control panel, diesel tank, battery charger, silencer exhaust connection, available exhaust extension piping (upto nominal length of 3 Mtrs) etc. i/c supply providing necessary gaskets, giving all required electrical and mechanical connections of exhaust, body & Neutral earthing, cable connection with available material at site, i/c supply and providing fuel connection for supply and return line with 20 mm nominal dia industrial quality nylon braided hose up to 7 Mtr (nominal length) with suitable banjo connector at both end, copper washers and screw type metal clip etc from fuel tank to engine etc as required including testing with exchange load.

-

-

-

... More
Upto 30 KVA Capacity

4

-

-

... More
Above 30 KVA upto 63 KVA Capacity

4

-

-

... More
Above 63 KVA upto 100 KVA

2

-

-

... More
Above 100 KVA upto 250 KVA

1

-

-

... More
Leading and positioning the canopy type/ RTU type EA set on the existing plinth/ room at ground floor etc as reqd. Installing the canopy type RTU, AMF/ Non AMF EA set including its associated work like silencer exhaust extension piping [upto nominal length of 3 Mtr] with the available pipe etc. i/c supply providing necessary gaskets, giving all required electrical and mechanical connections of exhaust, body & Neutral earthing, cable connection etc with available material at site etc including testing with exchange load as required.

-

-

-

... More
Upto 30 KVA Capacity

4

-

-

... More
Above 30 KVA upto 63 KVA Capacity

4

-

-

... More
Above 63 KVA upto 100 KVA

2

-

-

... More
Supplying, laying and fixing of one number PVC insulated and PVC sheathed/ XLPE Al power cable of 1.1KV grade of 4 C 25 sq.mm in following ways including all as required.

-

-

-

... More
On wall surface (clamped with 1mm thick saddle)

50

-

-

... More
Loose in duct/panel

20

-

-

... More
Supplying, laying and fixing of one number PVC insulated and PVC sheathed/ XLPE Al power cable of 1.1KV grade of 3.5 C 35 sq.mm in following ways including all as required.

-

-

-

... More
On wall surface (clamped with 1mm thick saddle)

50

-

-

... More
Loose in duct/panel

20

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
4 x 25 Sqmm

30

-

-

... More
3.5 x 35 Sqmm

20

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface /recess/in ground for extending EA neutral/ body earth including connection with G.I. nut, bolt, spring, washer etc. as required.

50

-

-

... More
Providing necessary arrangement for extending the EA set exhaust pipe (size 63 to100mm)out let to the outside of the EA room including supply and providing suitable flange and washers, welding grinding, supports etc. as reqd.

15

-

-

... More
Shifting the dismantled EA set from the plinth / position to a suitable location around a nomibnal 10 meter proximity in the same floor level without causing any damage etc as required

-

-

-

... More
Upto 30 KVA Capacity conventional type/Canopy / RTU type

8

-

-

... More
Above 30 KVA upto 63 KVA Capacity conventional type/Canopy / RTU type

8

-

-

... More
Above 63 KVA upto 100 KVA conventional type/Canopy / RTU type

3

-

-

... More
Above 100 KVA upto 250 KVA conventional type/Canopy / RTU type

1

-

-

... More
Lifting up / Lifting down of the EA set Upto 30 KVA Capacity conventional type/Canopy / RTU type - between the floors (from/ to the room or rooftop where the EA plinth located) as below with suitable crane/ pulley/ manpower arrangement as the per the site requirement without any damage etc complete as required.

-

-

-

... More
lifting up OR down between ground level and 1 st floor

1

-

-

... More
lifting up OR down between ground level and 2nd floor

2

-

-

... More
lifting up OR down between ground level and 3rd floor

2

-

-

... More
lifting up OR down between ground level and 4th floor

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.