Bharat Sanchar Nigam Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Bharat Sanchar Nigam Limited - BSNL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date1 Nov 2024
Closing Soon13 Nov 2024
Tender Amount₹ 8,80,134
Costs
EMD
₹ 17,603Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BSNL_213220_1Tender No
KRLCO-13/16(11)/51/2024-ELECTender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://https://www.bsnl.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Dismantling and removing the DC DB after removing all type of incoming and outgoing cable / conduit wirings connections, DC light point along with the wiring done for the exchange etc and shifting the same to a convenient place within the exchange premises without causing damage to the building and equipment as required.
10
-
-
Dismantling and removing the AC unit control cubicle panel of various size after removing all type of incoming and outgoing cable / conduit wirings connections etc and shifting the same to a convenient place within the exchange premises without causing damage to the building and equipment as required.
10
-
-
Dismantling and removing wiring done for AC units in surface / recessed metal / PVC conduit including dismantling and removing the industrial sockets, plug stations, DP isolators provided for AC units etc and shifting the same to a convenient place within the exchange premises without causing damage to the building and equipment as required.
10
-
-
Dismantling and removing oil / Air cooled SCVS up to capacity of 100 KVA after removing all type of incoming and outgoing cable connections, earthing connection, associated outgoing wiring/ cabling in various mode etc and shifting the same to a convenient place within the exchange premises without causing damage to the building and equipment as required.
4
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
6 way (4 + 18), Double door
2
-
-
Dismantling and removing existing the 3 compartment KSEB meter board cubicle after removal of the existing connection etc. and shifting the same to a convenient place within the exchange premises without causing damage to the building and equipment as required.
10
-
-
Fixing the 3 compartment KSEB meter board cubicle on the exisitng wall with suitable screws etc., giving nescessary electrical, mechanical and earthing connections inside the panel etc as reqd. [Nesessary coordination work should be done with KSEB Authority for getting service connection. Any approved payment regarding to the KSEB will be pay extra by BSNL]
8
-
-
Dismantling the following members of Fire alarm sytem from the wall / ceiling provided for the exchange after removing all electrical and mechanical nature connections, including dismantling removing the wiring provided for the members etc and shifting the same to a convenient place within the exchange premises without causing damage to the building and equipment as required.
-
-
-
FAP upto 8 zone
10
-
-
Detectors along with metal box
30
-
-
MCPs
20
-
-
Hooter / Siren
20
-
-
Dismantling various type of light fitting from wall / ceiling, various type fans/ exhaust fan from wall/ ceiling after removing its mechanical and electrical connection etc and shifting the same to a convenient place within the exchange premises without causing damage to the building and equipment as required.
60
-
-
Dismanling the outdoor and indoor unit of 1.5 TR Split Type AC unit, dismantling all electrical and mechanical connections, refrigerant pipes, prefab stand etc without making any damages to the unit and the building, handling the units for shifting and stacking the 1.5 TR Split type AC unit at the building premises etc as reqd.
10
-
-
Supply and fixing the following members in the existing KSEB meter cubicle/ DB i/c giving nescessary interconnections, testing and commissioning etc as required
-
-
-
63 A 4pole 300 m A ELCB
10
-
-
Extensible bus bar type porcelein Kit Kat fuse unit of 100 Amps capacity
15
-
-
Neutral Link
5
-
-
S/F 50 mm dia PVC pipe with accessories like bend, socket for service connection including necessary supports, clamping etc as required
20
-
-
Fixing the dismantled / available AC control Panel / LT panel of on the exisitng wall / floor with suitable screws etc as reqd.
8
-
-
Fixing the 125 A 4 pole change over switch (dismantled old item) on the wall / in existing panel with suitable screws including giving all mechanical and electrical connections etc as reqd
10
-
-
Supplying, laying and fixing of one number PVC insulated and PVC sheathed/ XLPE Al power cable of 1.1KV grade of 4 C 25 sq.mm in various manner including all accessories like clamp, screws, saddles etc as required.
100
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
-
-
-
4 x 25 Sqmm
30
-
-
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
100
-
-
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
-
-
-
3 x 1.5 Sq mm
70
-
-
6 x 1.5 Sq mm
25
-
-
3 x 2.5 Sq mm (for AC unit)
25
-
-
3 x 4 Sq mm (for AC unit)
25
-
-
Fixing the dismantled industrial socket/ DP isolator with enclosure/ DP Changeover isolator for controlling supply to AC units including giving connection etc as required.
10
-
-
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
-
-
-
Group C
20
-
-
Extra for cutting holes on wall suitable for fixing 12" exhaust fan etc. as reqd.
10
-
-
Fixing of exhaust fan along with its louver including replacing condensor, oiling, giving connection, testing and commissioning etc as reqd.
4
-
-
Supplying and drawing 25 Sqmm ABC Aluminium weather proof cable ( 4 core + 1 GI stay wire ) from EB post to Meter board i/c tieing / fixing at both ends with suitable fastners , pdg connections testing etc as required.
60
-
-
Providing fire alarm system for the exchange with the following dismantled members at suitable place on the wall / ceiling including rearranging existing conduit wiring/ cabling, fixing following items , testing etc as reqd.
-
-
-
FAP upto 8 zone
8
-
-
Detectors along with metal box
24
-
-
MCPs
16
-
-
Hooter / Siren
16
-
-
Redirecting the exisitng layed cable of size up to 70 Sq mm on surface of wall including dismantling the cable from wall / duct i/c giving termination giving connection etc as reqd.
100
-
-
Supplying and fixing PVC batten/ angle holder with 12 Watts LED bulb including supply and fixing suitable Round bock, connections, testing, commissioning etc. as required.
20
-
-
Supply and fixing digital thermostatic controller with range approx 20-40 degC with 4A potential free contacts working on 230V a.c. supply to operate one exhaust fan in suitable size PVC box i/c giving necesssary inter connection etc as reqd. ( SUBZERO- 7510/ 7569P/ TM&W or similar make. Model to be selected with approval of Engineer in charge.)
10
-
-
Supply and fixing 12" single phase 230 V 50 Hz 1350/1400 rpm heavy duty exhaust fan and louver assembly suitable for the fan including giving connection testing, commissioning etc as required. (Fan Make M/s Almonard or SS make)
6
-
-
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
25
-
-
Supplying and fixing step type electronic regulator for ceiling fan in the existing switch box / cover including connection,removing old regulator etc as required.
10
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
4
-
-
Supply and Laying 40 mm dia B class ISI marked GI pipe on surface of wall/ in ground for cable/ GI earth strip protection including supply and providing metal clamps, screws, phill rawls/excavation of soil etc. as required.
8
-
-
Supply and providing necessary termination box made out of 16 Guage MS sheet including providing its knock outs, suitable welding, drilling holes, grinding, painting etc including providing necessary bolt for fixing the cover etc as required.
2
-
-
Supply and fixing hinged door type SMC box of nominal size 65 cm x 35 cm x 21 cm on wall suitable for fixing the 3 phase KWh meter, etc as reqd. (Sintex GSMB-6535 or similar superior make). [Nesessary coordination work should be done with KSEB Authority for getting service connection. Any approved payment regarding to the KSEB will be pay extra by BSNL]
2
-
-
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
50
-
-
Supplying and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch on the existing switch board, including making necessary cutting on the phenolic laminated sheet, giving connections etc. as required.
6
-
-
Supplying and fixing 3 pin 5/6 A socket outlet on PVC box of 100mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing connections, painting etc. as required. (For wall Fan)
6
-
-
Supplying and fixing 400 mm sweep wall fan suitable for 230 V 50 Hz AC supply as required (M/s Bajaj Midea/superior make)
6
-
-
Supply and fixing 4 feet LED tube suitable for 230 V 50 Hz Ac supply on wall/ ceiling including giving connection etc as reqd.
20
-
-
Installation of 1.5 TR Split type AC unit giving its all kind of electrical and mechanical connection, providing necessary insulation over refrigerent pipings, doing necessary pressure testing vacuumising and gas topping up i/c fixing of the dismantled / available prefab/ stand etc as required.
3
-
-
S/F of copper refrigerant line combined suction/discharge pipe of required size, making thermal insulation with poliform sheet/ tube to extend the additional length as required
6
-
-
Gas charging of 1.5TR S/T AC unit with R-22 / A 407/ R- 32 etc refrigerant gas etc as required
3
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
20mm
90
-
-
25mm
50
-
-
Fixing of 32 Ampere up to 125 Ampere TPN switch (dismantled old item) in existing panel with suitable screws including giving all mechanical and electrical connections etc as reqd
3
-
-
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
-
-
-
4 way (4 + 12), Double door
5
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker/isolator suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single pole MCB
15
-
-
2pole 32A MCB
5
-
-
Triple pole and neutral 32A MCB
10
-
-
4 pole, 415 volts, 63 Amps Isolator
5
-
-
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
8
-
-
Dismantling the power cables from LT Panel of various sizes below 3.5x95sq.mm and giving connections temporarily to the change over switch outside the LT panel directly to facilitate dismantling/refixing of existing EB meter board/EA set and to minimise power outage in the telephone exchange etc as required. (as per the site requirement only)
10
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
6 way, Double door
5
-
-
Supply and fixing of three phase 415V,10-40A,class1,energy meter in the exisitng box, giving necessary interconnection to meter etc as reqd.(Make of meter : L&T ER 300 P or similar superior make)
3
-
-
Supply and fixing of single phase 230V,20A,class1 energy meter in the exisitng box, giving necessary interconnection to meter etc as reqd.(Make of meter : L&T EM101+ or similar superior make)
3
-
-
Supply and fixing hinged door type SMC meter box of nominal size 15 cm x 20 cm on wall suitable for fixing the above energy meter etc as reqd.
6
-
-
Reapiring and making good the 48" ceiling fan, including , testing etc. complete reqd as following.
-
-
-
dismantling, rewinding fan motor,cleaning and refxing with existing down rods
6
-
-
replacing the faulty capacitor with new one
6
-
-
painting the ceiling fan.
6
-
-
Repairing of 18' Exhaust fan motor including dismantling, to and fro cartage, refixing, giving connection, testing, commissioning etc reqd as following .
-
-
-
Rewinding the faulty Heavy duty exhaust fan motor , varnishing etc as reqd
6
-
-
Replacing faulty bearings / old burned bush and including providing of high speed bearing with necessary lathe works etc as reqd
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%