Bharat Sanchar Nigam Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 42,395Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_BSNL_224639_1Tender No
KRLCO-13/16(11)/70/2024-ELECTender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://https://www.bsnl.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Rate to be quoted for each quarter for Up to 6 zone conventional panels including its total members like repeater panel/ detectors/ MCP/ Hooter/ Siren up to 30 nos.
24
-
-
... More
Rate to be quoted for each quarter for Above 6 zone Up to 8 zone conventional panels including its total members like repeater panel/ detectors/ MCP/ Hooter/ Siren up to 50 nos.
64
-
-
... More
Important Note: 1)The initial defects of the AFDS panels shall be rectified by replacing the items listed in Part B. Upon completion of these repairs, the system will be restored to working condition, allowing the commencement of comprehensive maintenance. Following this, the AFDS panels, repeater panels, MCPs, hooters, sirens, and other related components will be covered under the comprehensive maintenance contract for the duration of the contract period
2) No additional payments will be made for any other items or services beyond the agreed scope.
3) All types of detectors are excluded from the comprehensive maintenance system and shall be replaced when faults are noticed, with the approval of the Engineer-in-Charge and shall be guaranteed for 1 year from the date of installation .
2) The fire alarm panels which are life expired and its spare parts were not available in market /life expired and obsolete /life expired and beyond repair /life expired and uneconomical to repair will be replaced by the department under capex head after being scrapped as per the extant guidelines.
-
-
-
... More
Checking the fire detection system of conventional or microprocessor-based panels in various exchanges/buildings that are not covered under the Comprehensive maintenance contract , on an on-call basis as per the direction of the Engineer in charge . This includes cleaning /servicing of the entire fire alarm detection system comprising of panel along with battery , repeater panel, MCP, Hooters, siren etc including conducting smoke testing of the fire detection system, and ensuring the system remains operational and up to standards, i/c attending breakdown calls (within 24 hours of intimation). This work is to be carried out for 42 Minor TE buildings, as detailed in the annexure.
Note :
1. The replacement of defective items with new one is not included in the scope of this item and it shall be executed as per the items listed in Part B Sl. No. 3 of the schedule), 2.Generally, the above job is intended to be carried out once every six months. However, the work may be performed as per the direction of the Engineer-in-Charge if site conditions demand.
-
-
-
... More
Up to 6 zone microprocessor / conventional panels including its total members like repeater panel/ detectors/ MCP/ Hooter/ Siren up to 30 nos.
80
-
-
... More
Above 6 zone Up to 12 zone microprocessor/ conventional panels including its total members like repeater panel/ detectors/ MCP/ Hooter/ Siren up to 50 nos.
88
-
-
... More
Part B
Servicing and Rectification of fire alarm system which are not covered under CMC including checking the fault, repairing/ replacing the following components, testing, commissioning etc as reqd .
[Note: The items replacing should have the compatibility for supporting the facility of the existing panel as per BSNL standards like continuously monitor OPEN, SHORT leads in each zone Fire detectors / Manual call point with audio alarm distinct for FIRE and FAULT and shall visually indicate FIRE / FAULT in corresponding zone and shall have the following visual indications for (a) System ON – Green (b) Stand by ON – Green (c) Charger ON – Green (d) Isolation of a zone for testing purpose. Audio-visual indication for the following (i) The operation of Fire detector in any zone. (ii) Short circuit or disconnection of leads in any zone (iii) Failure or disconnection of normal power supply. (iv) Failure or disconnection of standby power supply. (v) Failure or disconnection of battery charging equipment. (vi) Battery voltage low. (vii) Switch for acknowledgement.
-
-
-
... More
Note :
1. The following spares shall be used for the initial fault rectification of the Automatic Fire Detection System (AFDS) before the commencement of the Comprehensive Maintenance Contract (CMC). These spares shall not be used further after the commencement of the CMC for the sites coming under CMC -Sl No. 1 , except for the replacement of detectors .
2. The spares listed below shall be used to attend to routine periodical faults for the execution of work under Sl. No. 2. However, the agency must provide a one-year guarantee for the replaced spares from the date of installation except battery.
3.Agency has to give three year guarantee for the replaced new batteries from the date of installation.
-
-
-
... More
SMPS Power Card suitable for operating on 230 ± 10% 50 HZ single phase AC supply
10
-
-
... More
Mother Board suitable for up to 4 zone
5
-
-
... More
Display Card suitable for up to 4 zone
5
-
-
... More
Mother Board suitable for above 4 zone up to 6 zone
5
-
-
... More
Display Card suitable for above 4 zone up to 6 zone
5
-
-
... More
Mother Board suitable for above 6 zone up to 8 zone
4
-
-
... More
Display Card suitable for above 6 zone up to 8 zone
5
-
-
... More
Rectifier transformer suitable for operating in 240 V 50 Hz along with its rectifier assembly
6
-
-
... More
Charger card [shall not be greater than 13.6 V for 12 V battery ]
5
-
-
... More
NO NC relay of 3 sets
5
-
-
... More
Repairing the faulty zone card /mother card of conventional type by replacing / inter changing the minor Electronic Components such as IC, Transistor, capacitor, LED indication lamps etc and refixing the same including testing commissioning etc. as reqd
5
-
-
... More
Repairing the faulty zone card /mother card of microprocessor type by replacing / inter changing the minor Electronic Components such as IC, Transistor, capacitor, LED indication lamps etc and refixing the same including testing commissioning etc. as reqd
5
-
-
... More
Replacing the faulty Photo electric type detector with dual chamber on existing box i/c providing necessary connection and dismantling the old faulty one etc as reqd
150
-
-
... More
Replacing the faulty heat detector with dual chamber on existing box with new one i/c providing necessary connection and dismantling the old faulty one etc as reqd
10
-
-
... More
Repairing of Faulty Manual Call point by replacing the components/ PCB including testing, commissioning etc as reqd
20
-
-
... More
Repairing of Faulty Sounder/ Hooter by replacing the components/ PCB/ speaker including testing, commissioning etc as reqd
15
-
-
... More
Replacing the DC to DC converter (48V to 24V and 5 A rating) suitable for above mentioned fire alarm panel including giving connections etc as required.
60
-
-
... More
Supply approved type fire action notice and fixing the notice in prominently displayed manner in the site premises etc as required.
15
-
-
... More
Replacement of faulty battery which is life expired with new fully charged maintenance free battery 12V, 7AH in the existing control panel i/c giving connections etc as required (On buyback Basis) Note :
1. Faulty Batteries whose life has exceeded 3 years only are included in the scope of the above item.
16
-
-
... More
S/L of 2 x 1.5 sq mm copper conductor PVC insulated and sheathed armoured (FRLS) cable with (ISI mark) on the wall/ceiling/ existing cable tray etc as per specification i/c S/M cable end termination with brass gland for 2x1.5 sqmm required (M/s Finolex/ Havells / Polycab/ BSNL approved make).
100
-
-
... More
Part C -Maintenance , servicing and refilling of Fire extinguishers
-
-
-
... More
Periodical checking of the fire extinguishers with with minimum 90 days interval in the exchanges as per the specifications attached which includes physical verification of each extinguisher, verify that the hanger, bracket, or cabinet is secure, undamaged, and properly mounted, clean all exterior surface of the extinguisher with dry cloth and install back at its designated place, the extinguisher is full by weighing or hefting, extinguisher is not obviously damaged, corroded or leaking and does not have a clogged nozzle etc as required
-
-
-
... More
i) Exchanges having maximum of 10 fire extinguishers, varying in type and weight
400
-
-
... More
ii)Exchanges having 11-20 fire extinguishers, varying in type and weight
40
-
-
... More
iii) Exchanges having 21-30 fire extinguishers, varying in type and weight
16
-
-
... More
iii)Exchanges having 31-40 fire extinguishers, varying in type and weight
8
-
-
... More
iii) Exchanges having 41-50 fire extinguishers, varying in type and weight
8
-
-
... More
Recharging/refilling of the fire extinguisher as per the recommendation of the manufacturer by replacing the extinguishing medium with the same BIS rating marked on the extinguisher. The work involves internal inspection of the container, replacement of parts minor parts like washers ,safety pin,seals,pasting new stickers and of being recharged with media and propellant and restored to its full operating capability by means of the standard practices used by fire equipment service companies.
-
-
-
... More
Portable Fire extinguisher, carbon dioxide type 2/2.5 Kg
32
-
-
... More
Fire extinguisher, carbon dioxide type 3/3.2/3.5 Kg
8
-
-
... More
Fire extinguisher, carbon dioxide type 4.5 Kg
70
-
-
... More
Dry powder type 10 Kg ,ABC short pressure type
2
-
-
... More
Foam type stored pressure 9 Litre
20
-
-
... More
dry powder fire extinguisher 1kg/2 Kg
10
-
-
... More
dry powder fire extinguisher 5 Kg
10
-
-
... More
Hydrostatic pressure testing of the following type of extinguishers as per Indian Standard IS 2190 latest revision norms as required
-
-
-
... More
Portable Fire extinguisher, carbon dioxide type of all capacity
120
-
-
... More
Foam type extinguishers
20
-
-
... More
Replacing following parts of the extinguisher with new one etc as required
-
-
-
... More
Wire braided Hose suitable for all type of Co2 type Fire extinguisher
20
-
-
... More
Horn(flat/round ) suitable for all type of Co2 Fire extinguisher
20
-
-
... More
Hose suitable for 4/6/9 Kg foam type extinguisher
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%