Bharat Sanchar Nigam Limited Tender
Everything can be found here in your one-stop destination for all types of Kerala tenders online - be it Kerala PWD tenders or an LSGD Kerala tender. Search from across the categories, cities, and authorities while having the option to download tender-related documents. Also, get to know how to register as a bidder and how to bid online for Kerala tenders.
Costs
EMD
₹ 11,353Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BSNL_201807_1Bid Award Id
ViewTender No
KRLCO-13/16(11)/36/2024-ELECTTender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://https://www.bsnl.co.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supplying and filling of tested quality fresh transformer oil suitable for 11 KV system etc as required
40
-
-
Supply and replacing breather with fresh silica gel for the existing 630 kVA transformer etc as required
1
-
-
Refilling the breather with fresh silica gel after removing the hydrated gel, cleaning the assembly, refixing, etc as reqd.
1
-
-
Arresting the oil leak through primary side HT bush of 630 KVA Transformer(TR-2) i/c dismantling and removing of conservator tank and other accessories, lifting of top cover after draining out oil, rectification of leak through HT bush , replacing all the required gaskets, reassembling all accessories, re filling transformer oil etc complete as required.
1
-
-
Arresting the oil leak through secondary side LT neutral earth bush of 630 KVA Transformer ( TR-1) i/c dismantling and removing of conservator tank and other accessories, lifting of top cover after draining out oil, rectification of leak through LT bush , replacing all the required gaskets, reassembling all accessories, re filling transformer oil etc complete as required.
1
-
-
Supplying and fixing 11 KV HT bushing with copper terminals & studs i/c flexible copper conductor of suitable size & length with copper socket etc complete as required.
1
-
-
Cleaning the body of the existing 630 KVA ,11KV/415V, indoor oil cooled transformer to remove thick deposit of dust etc as required
2
-
-
Cleaning the dust inside and outside of the existing 1000 A bus bar trunking from transformers to main MV panel i/c removing the cover of the bus bar trunking , checking all the joints for any loose connection, tightening the same if required , refixing the trunking cover etc complete as required
25
-
-
S/F 3 mm thick plain glass of approximate size 42 cm x 19 cm to replace the broken front cover of the existing IDMT relay etc as required
1
-
-
Servicing of the following rating draw out type LT Air Circuit breaker i/c cleaning and checking all insulators, mechanical parts, all moving & fixed contacts ,secondary isolating contacts, all connections of CTs, built in protection release, control wiring ,lubricating all mechanical parts ,cleaning contact tips, applying petroleum jelly on all contacts , checking ,correcting, lubricating the break and make mechanism, safety shutter mechanism,earthing point and other necessary items etc as required
-
-
-
630 A ACB ( M/s English Electric)
2
-
-
800 A ACB ( M/s English Electric)
3
-
-
1250 A ACB ( M/s L&T)
1
-
-
S/F new socket type castle lock & key mechanism for the LT ACBs to replace the old damaged one i/c dismantling the old one, fixing the new one, checking and correcting the alignment of the same, testing etc complete as required.
2
-
-
Testing , Checking and correcting the pick up time and closing time of IDMT relay unit ( 2 OC & 1 EF) of the LT panel / HT panel and setting the desired over current and earth fault level with standard testing kit , checking and correcting connected control wiring in the panel , checking shunt trip circuit ,auxiliary switches , sub mitting the test certificates etc as required.
4
-
-
S/F 110 mm dia (OD) LT current transformer of ratio 800/5A to replace the faulty one i/c removing the same from the existing main bus bars, fixing the new one, giving connection, testing etc complete as required.
6
-
-
Supplying and fixing the following items to replace the faulty one i/c giving connection to new one , testing etc as required.
-
-
-
VSS (6A) suitable to select voltage between Phases & Individual Phases to neutral with OFF( M/s Salzar 61313 SAB13TDYR or SS make)
1
-
-
Analogue type voltmeter -500 V ( 72mm x72mm size)
1
-
-
CT type Analogue type ammeter -0 to 800A ( 144 mm x 144mm size)
1
-
-
LED indicator lamps of suitable shades
25
-
-
2A HRC fuse links
25
-
-
Programming of the existing DMFM in the MV panel/Sub LT Panel with the correct ratio of the existing CTs /other correct parameters to get proper reading from the DMFM etc complete as required .
1
-
-
Repairing of the existing MCCB ( main incomer ) trip warning audible alarm panel of approx size 30cm x 30cm x 25cm fixed on the side of the existing sub LT panel II , checking the control wiring, rectify the complaints , testing etc as required.
2
-
-
S/F general purpose 8 pin plug in relay suitable for 250 V , 10 A operation having 220 V coil supply to replace the faulty one etc complete as required.
2
-
-
Servicing of main MV Panel of approximate size 7 M ( L)x1 M (D)x2.4 M (H) comprising of the following switchgears like 1 No 1250A ACB ( DG incomer), 3 Nos 800A ACBs ( 2 Nos EB incomer + 1 No BC) , 2 Nos 630A ACBs ( DG Incomer + BC) all with 4 Nos mechanical castle key inter locks, 7 Nos. 400A MCCBs , 4 Nos 400 A TPN SDFs,4 Nos 250 A MCCBs, 2 Nos 250 A TPN SDFs, 2 Nos 125 A MCCBs, 2 Nos 125 A TPN SDFs, 1 No 100 A TPN SDF, 4 Nos 63A TPN SDFs, 2 Nos 32A TPN SDFs etc as outgoings, ammeters, voltmeters with selector switch indicator lamps including tightening of all control and power circuit connections, checking and tightening bus bar connections and cable terminations to avoid loose connections , cleaning and dedusting of the complete panel, sealing of unwanted opening/holes, replacing burnt/damaged cable lugs, rusted /damaged bolts nuts, providing suitable size thumb screws in place of missing ones , checking of mechanical interlocks and correcting its alignment , testing of the panel for IR values, , measuring the temperature on the main bus bars/cable terminations , recording the temperature values & IR values on load after servicing etc complete as required.
1
-
-
Servicing of sub LT Panel-II of main DELTA power plant approximate size 2.1 M ( L) x 0.35 M (D) x 2.2 M (H) comprising of the following switchgears like 2 Nos 400A MCCBs an incomers and 8 Nos 250A MCCBs as outgoings, digital multifunction meter , indicator lamps including tightening of all control and power circuit connections, checking and tightening bus bar connections and cable terminations to avoid loose connections , cleaning and de-dusting of the complete panel, sealing of unwanted opening/holes, replacing burnt/damaged cable lugs, rusted /damaged bolts nuts, providing suitable size thumb screws in place of missing ones , checking of mechanical interlocks and correcting its alignment , testing of the panel for IR values, measuring the temperature on the main bus bars/cable terminations , recording the temperature values & IR values on load after servicing etc complete as required.
1
-
-
Servicing of sub LT Panel-I for main EXICOM power plant of approximate size 1.8 M ( L) x 0.35 M (D) x 1.65 M (H) comprising of the following switchgears like 2 Nos 400A MCCBs an incomers and 3 Nos 250 A MCCBs as outgoings, digital multifunction meter , indicator lamps including tightening of all control and power circuit connections, checking and tightening bus bar connections and cable terminations to avoid loose connections , cleaning and de-dusting of the complete panel, sealing of unwanted opening/holes, replacing burnt/damaged cable lugs, rusted /damaged bolts nuts, providing suitable size thumb screws in place of missing ones , checking of mechanical interlocks and correcting its alignment , testing of the panel for IR values, measuring the temperature on the main bus bars/cable terminations , recording the temperature values & IR values on load after servicing etc complete as required.
1
-
-
Servicing of LT Panel of HPAC plat for GGSN &MSC room having approximate size 1.55M( L) x 0.4M(D) x 1.9M(H) comprising of the following switchgears like 2 Nos 250A MCCBs an incomers and 6/7 Nos 63 A TPN SDFs as outgoings, digital multifunction meter , indicator lamps including tightening of all control and power circuit connections, checking and tightening bus bar connections and cable terminations to avoid loose connections , cleaning and de-dusting of the complete panel, sealing of unwanted opening/holes, replacing burnt/damaged cable lugs, rusted /damaged bolts nuts, providing suitable size thumb screws in place of missing ones , checking of mechanical interlocks and correcting its alignment , testing of the panel for IR values, measuring the temperature on the main bus bars/cable terminations , recording the temperature values & IR values on load after servicing etc complete as required.
2
-
-
S/F of 125A , 4 Pole MCCB with spreader terminals suitable for 50 Hz, 440 V having thermal release range 100 to 125 A , breaking capacity 36 KA ( Ics=50% Icu) in the existing LT Panel i/c dismantling the damaged switch, providing necessary modification in the cubicle to suite with the existing MCCB , providing suitable size rotary handle with ROM , giving connection to main bus bars with suitable size bus bars ( if required) , testing etc complete as required(- M/s L&T , DN 0-125D, CM 90681OOLOOG or SS make)
1
-
-
S/F of 63 A , TPN SDF with 50 A HRC fuse links suitable for 50 Hz, 440 V in the existing LT Panel i/c dismantling the damaged switch, providing necessary modification in the existing cubicle to suite with the new switch , giving connection with main bus bars with suitable size bus bars/cables ( if required) , testing etc complete as required(- M/s L&T , FN 63 or SS make)
1
-
-
Supplying and fixing fire retardant electrically insulated, non skid type with fluted top and plain bottom or top with chequered finish synthetic mat suitable for all voltages not exceeding 11KV (dielectric strength) Confirming to BIS/IS standards, having minimum width of 1000 mm +/- 20 mm
3
-
-
Supplying and fixing fire retardant electrically insulated, non skid type with fluted top and plain bottom or top with chequered finish synthetic mat suitable for all voltages not exceeding 1.1KV (dielectric strength) Confirming to BIS/IS standards, having minimum width of 1000 mm +/- 20 mm
9
-
-
Locating the existing earth pits, cleaning the earth pit, checking of earth resistance values of earth electrodes i/c replacing the corroded/damaged funnels, bolts and nuts with new steel nuts & bolts of suitable size , sign writing painting etc complete as required ( Sub station + DG Sets)
16
-
-
Removing the sand in fire buckets (6 Nos) cleaning the bucket painting the bucket with fire red enamel paint outside, white enamel paint inside and black enamel paint in the bottom, sieving the sand to remove the dirt and debris and refilling the bucket with sand and topping up the sand etc complete as reqd .
1
-
-
S/F hand gloves suitable for operation of HT equipment of superior quality etc as required.
1
-
-
Supplying and fixing earth discharge rod with suitable length of flexible copper wire for earthing 11KV DP structures /HT cable etcas reqd.
1
-
-
Disconnecting the out going power cables ( 3 1/2 x 150 Sq mm to 3 1/2 x 240 Sq mm ) from the existing MCCBs/TPN SDFs of the main MV panel to the respective HPAC plant/main power plant and relaying and reconnecting the same in the spare switches available in the right side section of the 630A bus coupler of the main MV panel in order to ensure that supply to the most important installations like DELTA / EXCOM power plants and HPAC plants for GGSN/MSC can be maintained at all the time even during the execution of maintenance works on one section of the main MV panel etc complete as required. ( Note : These cables have to be recovered from the bottom of the existing main LT trench where 4 Nos X 3 1/2x400 Sq mm power cable were layed above the cables to be recovered ).
2
-
-
Design, printing and supply of the updated single line diagram of 2x630kVA substation using adhesive type vinyl paper and paste the same on 2/3mm thick form sheet and fix it on the wall with 25x3mm Al. frame on all 4 sides etc as reqd.( The lay out of the existing substation scheme will be given by BSNL).
3.5
-
-
Design, printing and fixing the signage/sticker using adhesive type vinyl paper on the existing panel board etc. as reqd.
6000
-
-
Supplying of Auto Digital AC/DC Clamp meter suitable for reading 1200A DC and 1000A AC, AC DC Voltages, Resistance etc as reqd (Make : MECO 3600+ or similar superior
1
-
-
Cleaning the exterior surface of the MV panels ,APFC panel , bus trunking and fire barrier to remove dust and dirt accumalated on them , spray painting the surface area with suitable and approved enamel paint including removing rusted particles and applying metallic primer/putty wherever required etc. as reqd.
120
-
-