Water Resources Department Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Water Resources Department - WRD Tender

Civil And Construction
Building Construction
Opening Date8 Jul 2022
Closing Date20 Jul 2022
Tender Amount₹ 1,15,45,996 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

Construction Of 8 Room School Building At Shirbur-chickgalagali (junjarakoppa)r.c Shirabur Part In Mudhol Tq.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
KSRB 2.5 : Earthwork excavation in all soil deposits and filling sides of foundation upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with all lead and lift including cost of all labour complete as per specifications. specification. No. KBS 2.9.9 / 2.9.10.1 / 2.1.1Including all leads and lifts and as directed by the Engineer In-charge of the work.

542.2

-

218506.6

... More
KSRB 4-1.3 : Providing and laying in position plain cement concrete of mix M7.5 with OPC cement @ 180kgs, with 40mm and down size graded granite metal coarse aggregates @0.85cum and fine aggregtes @ 0.57cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation and plinth, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 Including all leads and lifts and as directed by the Engineer In-charge of the work.

120.96

-

628871.04

... More
KSRB 4-1.7 : Providing and laying in position plain cement concrete of mix 1:3:6 with OPC cement @ 220kgs, with 20mm and down size graded granite metal coarse aggregates @0.84cum and fine aggregtes @ 0.56cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation,plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 Including all leads and lifts and as directed by the Engineer In-charge of the work.

4.26

-

23059.38

... More
KSRB 4.2.8 : Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.878cum and fine aggregtes @ 0.459cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation plinth and ground floor level for roof slabs, staircase, lintles, retaining walls, return walls, walls ( any thickness ) including attached plasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete as per specifications. Specification No. KBS 4.1, 4.6 Including all leads and lifts and as directed by the Engineer In-charge of the work.

282.135

-

1676446.17

... More
KSRB 4.2.10 : Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 24kgs, with 12mm and down size graded granite metal coarse aggregates @0.05175cum and fine aggregtes @ 0.0345cum, with superplastisiser @0.225lts, machine mixed, well compacted for plain chajja of 7.5 cms. average thickness, upto ground floor level, including cost of all materials, labour, HOM of machinery, finishing, curing, complete as per specifications. Specification No. KBS 4.1, 4.6 Including all leads and lifts and as directed by the Engineer In-charge of the work.

34.95

-

15517.8

... More
KSRB 4.9.2 : Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. Specification No. KBS 4.6.3 -do- TMT bars Fe 500 Including all leads and lifts and as directed by the Engineer In-charge of the work.

28.5

-

2003721

... More
KSRB 4-6.5 : Providing and removing centering, shuttering, strutting, propping etc., for columns, pillars, piers, abutments, post and struts, square / rectangular / polygon in plan including cost of all materials, labour complete as per specificaiton. Specification No. KBS 4.6.2 Including all leads and lifts and as directed by the Engineer In-charge of the work.

307.822

-

140366.83

... More
KSRB 4-6.6 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for columns, pillars, piers, post and struts, circular or curved in plan including cost of all materials, labour complete as per specificaiton. Specification No. KBS 4.6.2 Including all leads and lifts and as directed by the Engineer In-charge of the work.

62.21

-

54433.75

... More
KSRB 4-6.1 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons. Specification No. KBS 4.6.2 Including all leads and lifts and as directed by the Engineer In-charge of the work.

157.68

-

40208.4

... More
KSRB 4-6.7 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specificaitons. Specification No. KBS 4.6.2 Including all leads and lifts and as directed by the Engineer In-charge of the work.

884.11

-

258160.12

... More
KSRB 4-6.10 :Providing and removing centering, shuttering, strutting, propping etc., for chajjas, corbels etc., including edges including cost of all materials, labour complete as per specificaiton. Specification No. KBS 4.6.2 Including all leads and lifts and as directed by the Engineer In-charge of the work.

34.95

-

11184

... More
KSRB 4-6.2: Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for flat surface such as suspended floors, roofs, landings, balconies and likes thickness upto 200mm including cost of all materials, labour complete as per specifications, upto 3.50 mtr from GL Specification No. KBS 4.6.2 Including all leads and lifts and as directed by the Engineer In-charge of the work.

561.23

-

222247.08

... More
KSRB 4-6.9 :Providing and removing centering, shuttering, strutting, propping etc., for edges of slabs and breaks in floor, cills, plinth including cost of all materials, labour complete as per specificaiton. Specification No. KBS 4.6.2 Including all leads and lifts and as directed by the Engineer In-charge of the work.

20.08

-

14497.76

... More
KSRB 6-1.3 : Providing and constructing burnt brick masonry for basement and superstructure with approved quality of non-modular bricks of standard size of class designation 3.5 newton / sqmm with cement mortar 1:6 including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 Including all leads and lifts and as directed by the Engineer In-charge of the work.

160.48

-

966892

... More
KSRB 9-5.3 : Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors, styles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and styles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, HOM of machineries complete as per specifications. ( excluding cost of fixtures) Specification No. KBS 9.16 Including all leads and lifts and as directed by the Engineer In-charge of the work.

24.62

-

86908.6

... More
KSRB 9-16.3 : Providing and fixing in position Mathi /Nandi wood fully panelled shutters for windows with styles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, HOM of machineries complete as per specifications. (excluding cost of fixtures ) Specification No. KBS 9.34 Including all leads and lifts and as directed by the Engineer In-charge of the work.

69.56

-

254241.8

... More
KSRB 9.4-3 : Providing Mathi / Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, HOM of machineries complete as per specifications. Specification No. KBS 9.33 Including all leads and lifts and as directed by the Engineer In-charge of the work.

4.25

-

238650.25

... More
KSRB 9-27.1 : Fixing of door frame in an existing opening including embeeding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Including all leads and lifts and as directed by the Engineer In-charge of the work.

10

-

13690

... More
KSRB 9-27.2 : Fixing of window frame in an existing opening including embeeding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. Including all leads and lifts and as directed by the Engineer In-charge of the work.

30

-

27900

... More
KSRB 7.1 : Providing and fixing in position collapsible steel shutters with single or double leaf with vertical channel 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size, with top and bottom rails of T iron sections of 40x40x6 mm with 38mm dia steel pulleys complete with bolt and nuts, locking arrangements, stoppers, handles on both sides with 7.5cms openings at 10 cms. c to c applying a priming coat of red lead paint. cost of materials, labour, HOM of machinery complete as per specifications. size of gate 2.4mx1.4m Specification No. KBS 7.7 / 7.12 Including all leads and lifts and as directed by the Engineer In-charge of the work.

9.6

-

50016

... More
Providing and fixing M.S bars to windows and ventilators including cutting and making holes in fame work with two coats of approved paints Including all leads and lifts and as directed by the Engineer In-charge of the work.

1365.12

-

178830.72

... More
KSRB15-3.8 : Providing 18mm thick cement plaster in single coat with cement mortar 1:4, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications.Including all leads and lifts and as directed by the Engineer In-charge of the work.

778.03

-

202287.8

... More
KSRB15-3-13 : Providing 12mm thick cement plaster in single coat with cement mortar 1:3, to ceiling including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. Including all leads and lifts and as directed by the Engineer In-charge of the work.

561.33

-

131351.22

... More
KSRB15-3.2 : Providing 12mm thick cement plaster in single coat with cement mortar 1:4, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. Including all leads and lifts and as directed by the Engineer In-charge of the work.

1231.57

-

250008.71

... More
KSRB15-7 : Providing lime rendering for plastering to wall and ceiling, including cost of materials, labour, curing complete as per specifications. Including all leads and lifts and as directed by the Engineer In-charge of the work.

1792.8

-

57369.6

... More
KSRB15-3.14 : Providing 12mm thick cement plaster in single coat with cement mortar 1:4, to ceiling including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. Including all leads and lifts and as directed by the Engineer In-charge of the work.

587.69

-

131642.56

... More
KSRB15-4.2 Extra for providing and mixing waterproofing compound in cement plaster work at one kg per bag or in the proportion recommended by the manufacturers, for cement mortar 1:4, 12mm thick cost of materials complete as per specifications. Including all leads and lifts and as directed by the Engineer In-charge of the work.

587.69

-

2938.45

... More
KSRB 14.10-2: Flooring with 25mm to 40mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. Specification No. KBS Including all leads and lifts and as directed by the Engineer In-charge of the work.

583.44

-

750303.84

... More
KSRB 15-14.1 : Providing and applying two coats with oil bound washable distemper of approved brand and shade on wall surface including priming coat with distemper primer after throughly brooming the surface free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications. Including all leads and lifts and as directed by the Engineer In-charge of the work.

1792.8

-

197208

... More
KSRB 15-16.1 : Providing and finishing external walls in two coats with waterproof cement paint of approved brand and shade to give an even shade after throughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications. - do- with primer Including all leads and lifts and as directed by the Engineer In-charge of the work.

778.03

-

36567.41

... More
KSRB 15-17.4 : Applying priming coat over new wood surface and / or wood based surface, after brushing with ready mix enamel priming paint including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, sand papering and knotting ready mix paint including cost of materials, labour, complete as per specifications. Including all leads and lifts and as directed by the Engineer In-charge of the work.

285.48

-

14274

... More
KSRB 15-17.6 : Providing and applying painting two coats ( excluding priming coat ) on new wood surface and / or wood based surface with enamel paint to give an even shade, cleaning the surface of all dirt, dust and foreign matter, sand papering including cost of materials, labour, complete as per specifications. Including all leads and lifts and as directed by the Engineer In-charge of the work.

285.48

-

27691.56

... More
Providing wall black boards in CM 1:3 with 2 coats of black paint including finishing etc complete. Including all leads and lifts and as directed by the Engineer In-charge of the work.

14

-

10808

... More
KSRB 13-9.1: Providing and fixing to wall ceiling and floor high density polythylene pipes 6.00 kgf/sq.cm working pressure 110 mm dia out side dia with special flange compression type fittings wall clips, making good the wall, ceiling and floor, including cost of all materials labourcharges Hom of Eqipments and testing complete as per Specifications. Specification No. KBS13.2.15.2/13.9 Including all leads and lifts and as directed by the Engineer In-charge of the work.

20

-

11900

... More
KSRB 2-2.1 : Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in ordinary soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. after breaking of clods complete as per specifications. specification. No. KBS 2.1(a) / 2.3.5 Including all leads and lifts and as directed by the Engineer In-charge of the work.

71.13

-

21267.87

... More
Earthwork excavation for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in ordinary soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. after breaking of clods complete as per specifications. specification. No. KBS 2.1(a) / 2.3.5 Including all leads and lifts and as directed by the Engineer In-charge of the work.

9.99

-

3733.76

... More
KSRB 4-1.3 : Providing and laying in position plain cement concrete of mix 1:4:8 with OPC cement @ 180kgs, with 40mm and down size graded granite metal coarse aggregates @0.85cum and fine aggregtes @ 0.57cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation and plinth, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 Including all leads and lifts and as directed by the Engineer In-charge of the work.

7.3

-

37952.7

... More
KSRB 5.1-3 : Providing and constructing granite / trap / basalt rubble stone masonry in foundation with cement mortar 1:6 (uncoursed ), bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.12 Including all leads and lifts and as directed by the Engineer In-charge of the work.

17.52

-

63545.04

... More
KSRB 5.3-3 : Providing and constructing granite / trap / basalt size stone masonry in basement with cement mortar 1:6, edges of stones chistle dressed in courses not less than 15 cms high, bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.13 Including all leads and lifts and as directed by the Engineer In-charge of the work.

15.82

-

91629.44

... More
KSRB 4-1.7 : Providing and laying in position plain cement concrete of mix 1:3:6 with OPC cement @ 220kgs, with 20mm and down size graded granite metal coarse aggregates @0.84cum and fine aggregtes @ 0.56cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation,plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 Including all leads and lifts and as directed by the Engineer In-charge of the work.

2.01

-

10880.13

... More
KSRB 2.5 : Earthwork excavation in all soil deposits and filling sides of foundation upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with all lead and lift including cost of all labour complete as per specifications. specification. No. KBS 2.9.9 / 2.9.10.1 / 2.1.1 Including all leads and lifts and as directed by the Engineer In-charge of the work.

21.62

-

8712.86

... More
KSRB 6-4.3 : Providing and constructing burnt brick masonry with approved quality of modular bricks ground moulded of standard size of class designation 3.5 newton / sqmm with cement mortar1:6 for basement and superstructure with cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 Including all leads and lifts and as directed by the Engineer In-charge of the work.

16.98

-

107738.1

... More
KSRB 6-7.1 :Construction of partition wall 11.2 cms thick with non modular ground moulded burnt bricks of class designation 3.5 newton / sqmm with cement mortar 1:4 inlcuding providing and fixing plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35 mm. 100 mm. wide as per I.S. 2212/1991 at 7.5 m. c to c including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 Including all leads and lifts and as directed by the Engineer In-charge of the work.

2

-

1624

... More
KSRB 9.5-3 : Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors, styles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and styles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, HOM of machineries complete as per specifications. ( excluding cost of fixtures) Specification No. KBS 9.34 Doors Including all leads and lifts and as directed by the Engineer In-charge of the work.

3

-

10590

... More
KSRB 9.4-3 : Providing Mathi / Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, HOM of machineries complete as per specifications. Specification No. KBS 9.33 Including all leads and lifts and as directed by the Engineer In-charge of the work.

0.09

-

5053.77

... More
KSRB 7.7 : Providing and fixing in position in cement concrete 1:3:6 steel glazed windows and ventilators side hung/top hung fully openable as per approved drawings using Z angles of 25x33x3mm, weighing 1.419 Kg/m both for outer and inner frames and central mullion section of size 25x46x3mm. weighing 2.28Kg/m duly providing T section 19x19x3mm weighing 0.839 kg/m for glazing of windows not more than 34 cms. c to c including providing and fixing 4mm. thick reeded glass with teakwood beading of required size, all steel sections should confirm to I.S 7452:1990, 4nos. of holdfasts of approved size, section should be cut to length welded and electrically grinded subdividing frames of unit shall be tenonned and revetted into the frames electrically. All the steel surface shall be throughly cleaned free of rust and painted with one coat of anti-corosive paint and finishing with two coats of ready mix paint of approved colour and make including cost of materials, fixtures, labour and HOM of machinery complete as per specifications. Specification No. KBS 7.12.1 / 7.12.2 / 7.12.3 / 7.12 Including all leads and lifts and as directed by the Engineer In-charge of the work.

0.68

-

2660.84

... More
KSRB 4.2.3 : Providing and laying in position reinforced cement concrete of Design mix M20with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.46cum,with superplastocisers @ 3 liters confirming to IS 9103-1999 reafired -2008 at machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation for footings pedastals, retaining walls, return walls, walls ( any thickness ) including attached plasters, columns, pillars, posts, struts, buttresses, bed blocks, anchor blocks &plinths etc., including cost of all materials, labour, HOM of machinery, curing, complete as per specifications. Specification No. KBS 4.1, 4.6 Including all leads and lifts and as directed by the Engineer In-charge of the work.

1.25

-

7136.25

... More
KSRB15-3.11 : Providing 20mm thick cement plaster in single coat with cement mortar 1:4, to stone masonry & concrete surface including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. Including all leads and lifts and as directed by the Engineer In-charge of the work.

38.04

-

10270.8

... More
KSRB15-3.9 :Providing 18mm thick cement plaster in single coat with cement mortar 1:4, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. Including all leads and lifts and as directed by the Engineer In-charge of the work.

142.74

-

37112.4

... More
KSRB 14.7-2 : Providing and laying red oxide flooring 40 mm thick, with an under layer of 30mm thick M-15 cement concrete, using broken granite metal of 12.5mm nominal size and top layer of 10mm thick plaster with 1:3 cement mortar mixed with red oxide ( using 3.5 kg of red oxide per 50 kg of cement ) finished with floating coat of neat cement mixed with red oxide ( mix of same proportion ) , including cost of materials, labour, curing, complete as per specifications. Specification No. KBS 14.3 Including all leads and lifts and as directed by the Engineer In-charge of the work.

15.16

-

10081.4

... More
KSRB 14.10-2: Flooring with 20mm thick polished cadapa slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. Specification No. KBS Including all leads and lifts and as directed by the Engineer In-charge of the work.

27.6

-

38032.8

... More
KSRB 4-6.7 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specificaitons. Specification No. KBS 4.6.2 Including all leads and lifts and as directed by the Engineer In-charge of the work.

2.81

-

820.52

... More
KSRB 4-6.2 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for flat surface such as suspended floors, roofs, landings, balconies and likes, thickness upto 200 mm including cost of all materials, labour complete as per specificaitons. Specification No. KBS 4.6.2 up to 3.5mtr from ground level Including all leads and lifts and as directed by the Engineer In-charge of the work.

2.2

-

871.2

... More
KSRB 4.2.10 : Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 24kgs, with 12mm and down size graded granite metal coarse aggregates @0.05175cum and fine aggregtes @ 0.0345cum, with superplastisiser @0.225lts, machine mixed, well compacted for plain chajja of 7.5 cms. average thickness, upto ground floor level, including cost of all materials, labour, HOM of machinery, finishing, curing, complete as per specifications. Specification No. KBS 4.1, 4.6 Including all leads and lifts and as directed by the Engineer In-charge of the work.

0.93

-

412.92

... More
KSRB 4.9.2 : Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. Specification No. KBS 4.6.3-do- TMT bars Fe 500 Including all leads and lifts and as directed by the Engineer In-charge of the work.

75

-

5277

... More
KSRB 15-14.1 : Providing and applying two coats with oil bound washable distemper of approved brand and shade on wall surface including priming coat with distemper primer after throughly brooming the surface free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications. Including all leads and lifts and as directed by the Engineer In-charge of the work.

180.79

-

19886.9

... More
KSRB 15-17.1 : Applying priming coat over new wood surface and / or wood based surface with white lead paint priming including preparing the surface after thoroughly cleaning oil, grease, dirt and foreign matter, sand papering and knotting ready mix paint including cost of materials, labour, complete as per specifications. Including all leads and lifts and as directed by the Engineer In-charge of the work.

8.27

-

355.61

... More
KSRB 11-2 : Providing and fixing white vitreous china clay, water closet Orissa pattern of size 580 x 440mm with integral type footrests, 100mm S or P trap, 10 litre low level pvc flushing cistern (all are approved make ) with fittings C.I / M.S Brackets 32 mm diametre flush pipe fittings and clamps over flow arrangements with speacial and 25 mm mosqito proof coupling of approved desing painting of fittings and brackets cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11 Including all leads and lifts and as directed by the Engineer In-charge of the work.

2

-

10322

... More
Providing stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead). 10cms x 10cms Including all leads and lifts and as directed by the Engineer In-charge of the work.

2

-

380

... More
Providing and installation at site of work PVC pipes including cost of pipes and specials and labour including, lowering into trenches. Laying true to line and level perfect linking at joints leak proof including jointing of approved type with all labour & lift charges, handling charges including encasing the pipe alround to a depth not less than 15cm with gravel or selected earth available from excavation etc., complete.PRED SR 2012-13 P.No25 I No.3.1.1 110 mm dia 4 Kg/cm PVC Pipe Including all leads and lifts and as directed by the Engineer In-charge of the work.

30

-

6810

... More
KSRB 12-8.1 : Constructing brick masonry inspection chamber 455x610mm, and 450mm depth, ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS Including all leads and lifts and as directed by the Engineer In-charge of the work.

2

-

14128

... More
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch

20

-

4000

... More
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. ( Electrical PWD SR 2019-20 Page.No -5 Item.No - 2.1.1&2.1.2&2.1.3) Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch Including all leads and lifts and as directed by the Engineer In-charge of the work.

20

-

5500

... More
Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. ( Electrical PWD SR 2019-20 Page.No -5 Item.No - 2.1.1&2.1.2&2.1.3) Long point above 6Mtr upto 10Mtr from tapping point to out let via switch Including all leads and lifts and as directed by the Engineer In-charge of the work.

20

-

8000

... More
Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6 amps 3/5 way Including all leads and lifts and as directed by the Engineer In-charge of the work.

18

-

2376

... More
Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.32 Amps Flush/ projected type DP switch Including all leads and lifts and as directed by the Engineer In-charge of the work.

2

-

370

... More
Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.16 Amps Flush type SP switch Including all leads and lifts and as directed by the Engineer In-charge of the work.

2

-

196

... More
Supplying and fixing polished wood boand of made of not less than 15mm thick plank on both sides with plank made out of not more than 2 pieces and fixing the same the wall using tapered inverted wooden plugs screrws etc. ( Electrical PWD SR 2019-20 Page.No -24 ,Item.No - 5.6.1&5.6.2&5.6.4) Including all leads and lifts and as directed by the Engineer In-charge of the work. A (12"x12"x2")

12

-

1800

... More
Supplying and fixing polished wood boand of made of not less than 15mm thick plank on both sides with plank made out of not more than 2 pieces and fixing the same the wall using tapered inverted wooden plugs screrws etc. ( Electrical PWD SR 2019-20 Page.No -24 ,Item.No - 5.6.1&5.6.2&5.6.4) Including all leads and lifts and as directed by the Engineer In-charge of the work. B (10"x8"x1.5")

12

-

1080

... More
Supplying and fixing polished wood boand of made of not less than 15mm thick plank on both sides with plank made out of not more than 2 pieces and fixing the same the wall using tapered inverted wooden plugs screrws etc. ( Electrical PWD SR 2019-20 Page.No -24 ,Item.No - 5.6.1&5.6.2&5.6.4) Including all leads and lifts and as directed by the Engineer In-charge of the work. Including all leads and lifts and as directed by the Engineer In-charge of the work. C (8"x6"x1.5")

12

-

840

... More
Supplying and fixing a Drop light using one PBBC/Backelite pendent holder .pvc insulated twin twisted copper wire of 1010.3mm length upto 1000mm.one of 60/100 watts lamp of 230 volts garde and one of 5 amps bakelite ceiling rose fixed on existing wooden block of outlet. Including all leads and lifts and as directed by the Engineer In-charge of the work.

15

-

1815

... More
Supplying and fixing PBBC Backelite straight or slant batten holder and wiring within 60W/230volts lamps Including all leads and lifts and as directed by the Engineer In-charge of the work.

36

-

3168

... More
supplying Patti type flourescent tube light fitting of 4 ' -suitable for 28 watts flourescent tube fitting made put of M.S. Sheet and stove enameled with HF Electronic Ballast locking type brass contact holders mounted on double fold type sheet base fully wired for use on 230 volts AC. supply including T5 lamp. Including all leads and lifts and as directed by the Engineer In-charge of the work.

18

-

12042

... More
Fixing all types and all capacities of fluorescent/false ceiling/spot light/CFL /LED fittings indoor on the wall / ceiling/ rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps Including all leads and lifts and as directed by the Engineer In-charge of the work.

18

-

1980

... More
Supplying and fixing 6-32 Amps SP miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve , indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required.confirming to IEC 60898 Including all leads and lifts and as directed by the Engineer In-charge of the work.

2

-

868

... More
Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. Including all leads and lifts and as directed by the Engineer In-charge of the work.

2

-

1920

... More
Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. Including all leads and lifts and as directed by the Engineer In-charge of the work.

100

-

5300

... More
Supplying and fixing cast alluminium round or oblong type bulk head fitting with GI wire guard ,glass cover with 15 watts 230 volts CFL lamps. Including all leads and lifts and as directed by the Engineer In-charge of the work.

8

-

7616

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694-1990 & confirming to GTP Group-A Including all leads and lifts and as directed by the Engineer In-charge of the work. ( 2.5 Sqmm)

178

-

5696

... More
Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. Including all leads and lifts and as directed by the Engineer In-charge of the work.

100

-

1900

... More
supplying, fixing , wiring, earth electrode for grounding conduits. I.C, cutouts and other equipment's on the meter board using 40mm dia 2.90 mm thick GI pipe 2.5 mtr long buired in a pit… The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc. is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc. the pipe shall have 16 through holes of 122 mm dia. Including all leads and lifts and as directed by the Engineer In-charge of the work.

1

-

2999.7

... More
SHORT POLES where as clearance between messenger wire and ground is inadequate a)Supplying and fixing 40mm dia. 2.9mm thick GI pipe, 1.8m long complete with atleast 2G.I pipe 1.8m long complete with ateast 2 nos of through out bolts 12mm dia with M.S back plate 100x100x6mm as per approved drawing .(for single phase installation;) Including all leads and lifts and as directed by the Engineer In-charge of the work.

1

-

625

... More
Supplying and fixing guy set for items 1(a) and (b) (wherever span exceed 10mm) formed out of not less than 4mm (8 SWG) G.I wire with I-bolt or 10mm) formed out of not less than 12mm dia with cement concreting work including 1 break insulator as per approved drawing .if a suitable wall or RCC roof is not available for anchoring guy sets the anchoring has to be done by done by fixing G.I wire to the rafter of the tile or asbestos. Including all leads and lifts and as directed by the Engineer In-charge of the work.

1

-

275

... More
INSULATED CABLE ON MESSENGER WIRE (SINGLE PHASE AND THREE PHASE) using two single core wires for a single phase and four single core wire for three phase. Supplying and stringing PVC insulated and PVC sheathed 650/1100 V-class alluminium conducter of size supported by 3.15mm(10 SWG) G.I messenger wire with two break insulator . one at each end of the span with suspenders at intervals of 0.75m. Each suspender shall be of oorcelain reel insulator suitable core through which insulated wire passes (Single core or twin core as the case may be) and this reel insulator shall be fixed to the messenger wire using 2mm (No:14 SWG) G.I wire suitably bent and twisted .Seperate reel insulator shall be provided for each wire the messenger wire shall be dead ended on the clamp provided to the departmental pole wide item No:4 -do- single phase using 2 wire 10 sqmm. Including all leads and lifts and as directed by the Engineer In-charge of the work.

30

-

2310

... More
Supply of horizontal type street light flouroscent fitting suitable for single /twin lamp of 24 w/ 28w FTL T5 lamp housing shall be with pressure die cast alluminium with UV protected clear arcylic diffuser with thirmo formed & CRCA gear tray, push fit poly corbonate lamp holder, low loss high frequency electronic ballast with IP 54 protection Including all leads and lifts and as directed by the Engineer In-charge of the work.

2

-

8404

... More
Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. Including all leads and lifts and as directed by the Engineer In-charge of the work. 32 amps

2

-

348

... More
supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc. for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Economy model.Including all leads and lifts and as directed by the Engineer In-charge of the work. Fans

10

-

20900

... More
Fixing a ceiling/Wall mounting fan of all capacities and all types to the existing S hook with fan regulator to the existing board together with supplying and fixing a 5 amperes ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring completely.Including all leads and lifts and as directed by the Engineer In-charge of the work. Fans

10

-

1500

... More
"supplying and installation/Fixing/Provision of 300mmx300mmx214mm Outdoor type Thermoplastic Modular Panel enclosure with transparent polycarbonate Lid, shock proof, IP65 (Weather Proof) rust proof, dust proof, water proof, corrosion proof, having internally Embedded gasket on both lid and flap suitable to fix Single phase/Three phase Energy Meter in suitable base plate and having a provision for Fuse/MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility Including all leads and lifts and as directed by the Engineer In-charge of the work. 300mmx300mmx214

1

-

3754

... More
KSRB13-4.1 : Making connection of G.I distribution branch with G.I main of 25 to 40mm. nominal bore, including cutting and threading the pipes, providing and fixing Tee, nuts, labour for all item of works, testing and HOM of equipments complete as per specifications. Specification No.KBS 13.10 Including all leads and lifts and as directed by the Engineer In-charge of the work.

1

-

483

... More
KSRB13-7.1-1 : Providing and fixing in position 25mm nominal bore gun metal non-return valve horizontal type of approved make including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS 13.2.10 / 13.13 Including all leads and lifts and as directed by the Engineer In-charge of the work.

2

-

1174

... More
KSRB13-6.1-2 : Providing and fixing in position brass bib cock of approved quality 20 mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS 13.2.2 / 13.3 Including all leads and lifts and as directed by the Engineer In-charge of the work.

5

-

865

... More
KSRB 11-11.1 : Providing and fixing white vitreous china clay, flat back wash basin size 630x450mm with a pair of 15mm C.P brass pillar taps with C.I / M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11 Including all leads and lifts and as directed by the Engineer In-charge of the work.

3

-

12021

... More
KSRB13-10.2 : Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm working pressure __mm outside diameter chemp plast / Wavin or equivalent make with pipe fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.4 / 13.9 Including all leads and lifts and as directed by the Engineer In-charge of the work. 20mm dia

75

-

8025

... More
KSRB13-10.2 : Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm working pressure __mm outside diameter chemp plast / Wavin or equivalent make with pipe fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.4 / 13.9 Including all leads and lifts and as directed by the Engineer In-charge of the work. 25mmdia

150

-

17700

... More
KSRB 12-1.1 : Providing and laying in position to required level or slope 100mm internal diameter salt glazed stoneware pipes grade A and jointing with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and joints,including cost of materials, labour charges complete as per specifications. Specification No. KBS 12.2.5 / 12.7 Including all leads and lifts and as directed by the Engineer In-charge of the work.

5

-

1225

... More
KSRB 13-11.1 : Providing and placing on terrace, polyethylene water storage tanks as per IS 12701: 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.(For 1000 litre capacity) Specification No.KBS 13.22 Including all leads and lifts and as directed by the Engineer In-charge of the work.

1

-

6828

... More
KSRB 11-15.2 : Providing and fixing 450mm dia circular shape mirror with plastic moulded frame of approved make and shade with 6mm thick hard board backing including cost of materials, labour complete as per specifications.

2

-

1650

... More
KSRB 12-8.1 : Constructing brick masonry inspection chamber 455x610mm, and 450mm depth, ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS Including all leads and lifts and as directed by the Engineer In-charge of the work.

2

-

14128

... More
KSRB 8.6-7 : Providing and fixing on wall surface 4.00 kg / sq.cm H.D.P.E. rain down water pipes 110 mm outer dia approved make and brand with necessary specials like shoes, bends and offsets fixed with iron clamps, wall plugs, screws, including cost of materials, labour, curing complete as per specifications. Including all leads and lifts and as directed by the Engineer In-charge of the work.

63

-

32256



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.