Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

University Of Horticultural Science - UHS Tender

Education And Training Services
Opening Date26 Apr 2021
Closing Date27 May 2021
Tender Amount₹ 3,01,83,739 
This is an estimated amount, exact amount may vary.
Notes
Download

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
KSRB 2.3 : Filling available excavated earth ( excluding rock ) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as per specifications.

1306

-

283506.48

... More
KSRB 2.5 : Earthwork excavation in all soil deposits and filling sides of foundation upto plinth in layers not exceeding 20cms. in depth, compacting each deposited layer by ramming after watering with all lead and lift including cost of all labour complete as per specifications. specification. No. KBS 2.9.9 / 2.9.10.1 / 2.1.1 Ground Floor

930

-

404773.2

... More
KSRB 4-1.7 : Providing and laying in position plain cement concrete of mix 1:3:6 with OPC cement @ 220Kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.84 Cum and fine aggregates @ 0.56 Cum machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation and cills, coping. plinth, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2

21

-

125943.72

... More
KSRB 4-1.3 : Providing and laying in position plain cement concrete of mix 1:4:8 with OPC cement @ 180kgs, with 40mm and down size graded granite metal coarse aggregates @ 0.85 Cum and fine aggregates @ 0.57 Cum machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation and plinth, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 Ground Floor

358

-

2049847.14

... More
KSRB 4-1.6 ; Providing and laying in position plain cement concrete of mix 1:2:4 with cement @240Kgs. with 20mm and down size graded granite metal coarse aggregates @ 0.878 cum and fine aggregates @ 0.459 cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation,plinth and cills, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2. Upto 3.50m Level Ground Floor

9

-

55289.88

... More
First Floor

1

-

6208.12

... More
KSRB 4.2.1 : Providing and laying in position reinforced cement concrete of Design mix M25 with OPC cement @ 340kgs, with 20mm and down size graded granite metal coarse aggregates @0.70 cum and fine aggregtes @ 0.47cum, with super plasticisers @ 3 liters confirming to Is 9103-1999 reafirmed-2008 at machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, walls (any thickness) including attached pilasters, columnspillars, posts, struts, buttresses, bed blocks, anchor blocks & plinths etc., including cost of all materials, labour, HOM of machinery, curing, complete as per specifications. Specification No. KBS 4.1, 4.6 Ground Floor

401

-

2680420.34

... More
KSRB 4.2.7 : Providing and laying in position reinforced cement concrete of design mix M25 with OPC cement @ 340kgs, with 20mm and down size graded granite metal coarse aggregates @0.70cum and fine aggregtes @ 0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintels and plinth beams retaining walls, return walls, walls (any thickness) including attached pilasters, columns, lintles, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 Ground Floor

348

-

2413721.04

... More
Terrace Floor

18

-

126014.04

... More
KSRB 4.2.11 : Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 24Kgs, with 12mm and down size graded granite metal coarse aggregates @ 0.5175cum and fine aggregates @ 0.345 cum, with superplastisiser @ 0.225ltr, machine mixed, well compacted for plain chajja of 7.5 cms. average thickness, upto Upper Ground Floor level, including cost of all materials, labour, HOM of machinery, finishing, curing,complete as per specifications. Specification No. KBS 4.1, 4.6.Upto 3.50m Level. Ground Floor

34

-

19190.96

... More
Terrace Floor

2

-

1139.68

... More
Providing Primary T.M.T. steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. Upto 3.50m Level. TMT bars Fe 500 Ground Floor

83

-

6882152.5

... More
Terrace Floor

1

-

83427.26

... More
Fabrication supplying and erecting M.S. tubular trusses of all spans as per approved drawing & design with prefabricated steel applications using quality material and are durable, reliable and corrosion and abrasion resistant. Welding shall confirm to latest structural welding code. Quality shall be on various parameters like shape, size, design gauge and polish. The entire trusses is anchored in RCC column by using 4 nos of M.S. anchor bolts at each support with 10mm thick base plate and shoe plate. The work includes cutting, straightening, placing in position of M.S. pipes and welding wherever necessary and applying one coat of redoxide primer coat to all the members including cost of all materials, labour charges, and hire charges of machineries for cutting, welding, grinding and erection equipments, with all lead and lift, transportation, letc., complete as per specification- For Pergola

2378

-

285074.64

... More
Centering & shuttering: KSRB 4-6.1 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, RCC Raft / footings, bases of columns for mass concrete including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 Ground Floor

491

-

136812.24

... More
KSRB 4-6.4 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for vertical surface such as walls at any thickness, including attached pilasters, buttresses, plinth cills and string courses cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 Ground Floor

14

-

5412.96

... More
KSRB 4-6.5 :Providing and removing centering, shuttering, strutting, propping etc., for columns, pillars, piers, abutments, post and struts, square / rectangular / polygon in plan including cost of all materials, labour complete as per specification. Specification No. KBS 4.6.2 Upto 3.50m Level. Ground Floor

753

-

370837.44

... More
Terrace Floor

37

-

18421.56

... More
KSRB 4-6.7 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of Plinth beams/ Tie, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications. Ground Floor

363

-

114475.68

... More
KSRB 4-6.7 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams/ Tie, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications. Upto 3.50m Level Ground Floor

1089

-

343427.04

... More
Terrace Floor

1013

-

324929.88

... More
KSRB 4-6.7 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams/ Tie, beam haunchings, cantilever girders, bressumers and lintels / Neamsnot exceeding 1m in depth including cost of all materials, labour complete as per specifications. Upto 3.50m Level. Ground Floor

274

-

86408.64

... More
Terrace Floor

167

-

53566.92

... More
KSRB 4-6.11 :'Providing and removing centering, shuttering, strutting, propping etc., removal of form work for stairs (excluding landing) except spiral staircase including cost of all materials, labour complete as per specification. Specification No. KBS 4.6.2 Upto 3.50m Level. Ground Floor

21

-

11793.6

... More
KSRB 4-6.2 : 'Providing and removing centering, shuttering, strutting, propping etc., removal of form work for flat surface such as suspended floors,Slab roofs, landings, balconies and likes, thickness upto 200 mm including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2. Upto 3.50m Level Ground Floor

1218

-

526176

... More
Terrace Floor

7

-

3061.8

... More
KSRB 4-6.9 :Providing and removing centering, shuttering, strutting, propping etc., for edges of slabs and breaks in floor including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 Ground Floor

37

-

30169.8

... More
Terrace Floor

2

-

1641.6

... More
KSRB 4-6.10 :Providing and removing centering, shuttering, strutting, propping etc., for chejjas, corbels etc., including edges including cost of all materials, labour complete as per specification. Specification No. KBS 4.6.2. Upto 3.50m Level. Ground Floor

48

-

16744.32

... More
Terrace Floor

2

-

708.48

... More
KSRB 5.1.3 : Providing and constructing granite / trap / basalt rubble stone masonry in foundation with cement mortar 1:6 (uncoursed), bond stones at 2m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.12 Ground Floor

229

-

924619.56

... More
KSRB 6-1.3. :Providing and constructing burnt brick masonry with approved quality of non-modular bricks of standard size of class designation 3.5 Newton per sqmm with cement mortar for basement and superstructure including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 Ground Floor

291

-

1657058.76

... More
Terrace Floor

15

-

85847.7

... More
KSRB 6-7.1: Construction of partition wall 11.2 cms thick with non modular ground moulded burnt bricks of class designation 3.5 Newton per sqmm with cement mortar 1:4 including providing and fixing plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35 mm. 100 mm. wide as per I.S. 2212/1991 at 7.5 m. c to c including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 Ground Floor

167

-

127853.53

... More
Terrace Floor

242

-

194420.38

... More
KSRB 5-15: Providing and constructing non load bearing wall with solid concrete blocks of size 400X100X200mm having a block density not less than 1800kg/m2 having a minimum average compressive strength of 4.00 N/mm2 confirming to IS 2185 (part1):2005 and constructed with CM 1:4, as per IS 2572 including cost of all materials, labour charges,scaffolding, curing .hiore charges of machineries etc., complete as per specifications. KSB No.5.4

82

-

72558.52

... More
DOORS AND WINDOWS KSRB 9.4-5 : Providing Red Sal wood frames wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, HOM of machineries complete as per specifications. Specification No. KBS 9.33 Ground Floor

2

-

130926.24

... More
KSRB 9-27.1 : Fixing of door frame in an existing opening including embeeding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.

15

-

22129.2

... More
Providing and fixing MS holdfast of size 260mm x25mm x5mm thck for fixing door frame to walls including cost of materials, cutting masonary pockets for receiving MS holdfast, one coat of shop primer, concrete filling of pockets, disposal of debris, keeping the area clean , curing , labour ets., complete as per specifications of vendor and as per architects details.

188

-

1633.72

... More
Providng and fixing SS304 5"x3"x3mm PI Jt Butt hinges for fixing door shutters to frame including cost of materials, labour etc.complete as per specifications of vendor and as per architects details

94

-

37882

... More
Providing and fixing SS 304 Door handle -150mm long (C - shaped) for door shutters including SS screws cost of materials, labour etc, complete as per specifications of vendor and as per architects details.

63

-

9828

... More
Providing and fixing SS 304 Aldrop -200mm x 16mm for door shutters including cost of materials, labour etc, complete as per specifications of vendor and as per architects details

32

-

8288

... More
Providing and fixing Hydraulic door closure- with mounting heavy duty ,suitable for Flush door shutters including cost of materials, labour etc, complete as per specifications of vendor and as per architects details. Make Godrej or any equivalent

9

-

22518

... More
Providing and fixing SS Door stopper - Heavy suitable for Flush door shutters including SS screws cost of materials, labour etc, complete as per specifications of vendor and as per architects details

16

-

2464

... More
Providng and fixing SS tower bolts for door shutters including cost of materials, labour etc complete as per specification of vendor and as per architects details

32

-

21504

... More
Providing and fixing Mortise lock suitable for Flush door shutters including cost of materials, labour et, complete as per specifications of vendor and as per architects details Make Godrej or any equivalent

16

-

27792

... More
Providing and fixing flush door shutter made out of solid core black board type, well seasoned chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as per specification. - 35mm thick both side Teak Ground Floor

31

-

132045.12

... More
Terrace Floor

3

-

12791.52

... More
Engineered wood plastic composite door frames with cross section of 75 x 125 mm Providing and fixing engineered wood door frame fabricated using Wood Plastic Composites profiles (WPC) of cross section 75 mm X 125mm with a density of 1250-1300 kg/m3, resistant to water, termite, fungal and UV, using four numbers of L shaped MS or plastic clamps at the corners of the frame to fix it firmly to form a rectangular shape door frame and provided with six numbers of 260mmx25mmx5mm size z shaped MS flat hold fasts for fixing the door frame in the wall and the material and process for manufacturing the door frame confirming to RV-TIFAC Composite Designs and Specifications including all costs of labour, materials, fabrication, assembling, transportation, erection, incidental and unforeseen charges complete as per the directions of the engineer in charge of the work , but excluding the cost of fixtures and painting. Ground Floor

1

-

2160

... More
Engineered Coir Composite Flush Door Shutter of 30mm Thick. Providing and fixing engineered coir composite flush door shutter manufactured using infill solid core with coir and wood particle blended with high quality polymer encased with 28mm thick wooden styles and rails all-round the boundary of the shutter and veneer laminated with non oven coir felt impregnated with high temperature cure phenol formaldehyde resin of density 800kg/cum with high quality adhesive processed at 155 Deg.C , using 650 tonnage hot compression moulding press and all four sides of the door shutter coated with water resistant coating and whole process of manufacturing confirming to RV-TIFAC Composite Designs and Specifications including all costs of labour, materials, fabrication, assembling, transportation, erection, incidental and unforeseen charges complete as per the directions of the engineer in charge of the work , but excluding the cost of fixtures and painting. Ground Floor

26

-

146577.6

... More
Providing and fixing of UPVC double door, made out of multi chambered UPVC sections with TPv gaskets having isolated drainage and reinforced with GI throughout the door.1.5mm of GI. Glazing bead for fixng of glass shall be of size 20X 18mm and coextruded with gasketr. Doors shall be provided with 5mm plain float glass, standard hardware and single point locking system of flush lock. The rate includes cost of all materials, labour, hire of tools & machineries, as per specifications etc complete. The rate includes cost of all materials, labour, hire of tools & machineries, as per specifications. Ground Floor

4

-

22240

... More
Providing and fixing of UPVC Glazed 3 track - 2 Panel sliding windows with Mosquito Mesh, made out of multi chambered uPVC sections with TPv gaskets having isolated drainage and reinforced with GI throughout the window, the sliding quter frame having a overall size of 108 X 45mm with reinforcement of 1mm thickness, sash with overall size of 39 X 58mm with reinforcement of 1.5 mm thickness, mesh sash of overall size 30X 48.5mm reinforced with 1.5mm of GI. Glazing bead for fiixng of glass shall be of size 20X 18mm and coextruded with gasket. Fiber Glass mesh shall be provided in mesh shutter. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system of flush lock. Wall thickness of frame , mullion and sash shall be 2-2.2mm Ground Floor

83

-

467920.8

... More
Terrace Floor

3

-

16912.8

... More
Providing & Fixing Louvered Ventilator made out of multi chambered uPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV (Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profiles through out the ventilator frame. The outer frame having a overall size of 39mmx39mm with GI reinforcement of 1 mm thickness. Louver clip in Aluminum (powder coated white) will be used on the frame along with plastic parts for fixing the 4mm pin headed glass. Wall thickness of frame shall be 2mm. Maximum possble size - 1000mm x 1000mm Ground Floor

6

-

23535.36

... More
KSRB 7.1 : Providing and fixing in position collapsible steel shutters with single or double leaf with vertical channel 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size, with top and bottom rails of T iron sections of 40x40x6 mm with 38mm dia steel pulleys complete with bolt and nuts, locking arrangements, stoppers, handles on both sides with 7.5cms openings at 10 cms. c to c applying a priming coat of red lead paint. cost of materials, labour, HOM of machinery complete as per specifications. size of gate 2.4mx1.4m Specification No. KBS 7.7 / 7.12 Ground Floor

18

-

101282.4

... More
KSRB 7.9 :Providing and fixing M.S.grill work for windows and ventilators weighing 21kg/sqm using M.S.flats, or M.S.square rods, or combination of M.S.flats and square rods as per approved design, drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer, cost of materials, fixtures, labour and HOM of machinery complete as per specifications. Specification No. KBS 7.12 Upto 3.50m Level. Ground Floor

3102

-

318265.2

... More
Terrace Floor

85

-

9271.8

... More
Providing and fixing Grade 304 Stainless Steel Railing upto 0.9m height with First Class Teak wood for Top Hand rail of size 50 X 100mm fixed to SS flat of size 50mm X5mm, including teakwood polishing, 50mm x 50mm box sections as Balustrades at every 0.9m spacing, Blasturade is to be based on ELEN Key bolt fitting system and 10mm dia strings to be fixed horizontally between the balustrades at 150mm interval space between the strings, fixing to done using SS plates and anchor bolts as per design and drawing including cost of materials, fabrication charges, labour, making holes for fixing strings etc complete. Ground Floor

8

-

46465.92

... More
PLASTERING WORKS : KSRB15-3-13 :Providing 12mm thick cement plaster in single coat with cement mortar 1:3, to ceiling including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials,labour, curing complete as per specifications.Upto 3.50m Level Ground Floor

1279

-

301421.93

... More
Terrace Floor

7

-

1695.05

... More
KSRB15-3.2 :Providing 15mm thick cement plaster in single coat with cement mortar 1:4, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. Upto 3.50m Level. Ground Floor

2240

-

550748.8

... More
Terrace Floor

85

-

21449.75

... More
KSRB15-3.8 :Providing 18mm thick sand finish cement plaster in single coat with cement mortar 1:4, to brick masonry including rounding off corners: Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. Upto 3.50m Level. Ground Floor

656

-

190810.72

... More
Terrace Floor

526

-

156406.1

... More
KSRB 15.8.2 Providing and fixing plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment )

221

-

7399.08

... More
15-4.4 Extra for providing and mixing waterproofing compound in cement plaster work at one kg per bag or in the proportion recommeanded by the manufacturers,for cement mortar 1:4,18mm thick cost of materilas complete as per specifcations. Ground Floor

84

-

816.48

... More
15-3.4:Providing 15mm thick rough cement plaster in single coat with cement mortar 1:4 to brick masonry including rounding off corners wherever required smooth rendering, including Providing and removing scaffolding, cost of materials, labour, curing complete as per specifications. (For Dadoing / Cladding ) Ground Floor

191

-

46961.17

... More
KSRB 15-6: Providing floating coat of cement to plastering and finishing smooth, including cost of materials, labour, curing complete as per specifications Ground Floor

202

-

4482.38

... More
Providing vitrified tiles 60 x 60cms of approved make, shade and size for flooring laid on a bed of 12mm thick cement mortar 1:3 mix, flush pointing with white cement, using SPACERS AS RECOMENDED BY ARCHITECT, colour pigment, including cost of materials, labour, curing complete as per specification. Ground Floor

760

-

738720

... More
Terrace Floor

15

-

14612.4

... More
P/F m/c cut & polished vitrified for skirting, 100mm high including cutting wall faces, fixing the tiles flush with plastered surfaces, top edge finishing etc. complete. Ground Floor

343

-

333396

... More
Terrace Floor

14

-

13638.24

... More
Providing & fixing Vitrified tile daddoing using 600X600mm size vitrified tiles from approved make fixied on the wall using CM 1:3 mixm flush pointing with white cement and colour pigment, using SPACERS AS RECOMENDED BY ARCHITECT, incliding cost of materials m labourm curing etc complete as per specifications. Ground Floor

191

-

185652

... More
Providing & fixing Anti Skid Vitrified tile Flooring using 600X600mm size vitrified tiles from approved make fixied on the wall using CM 1:3 mixm flush pointing with white cement and colour pigment, using SPACERS AS RECOMENDED BY ARCHITECT, incliding cost of materials m labourm curing etc complete as per specifications. Ground Floor

84

-

81648

... More
Providing and laying flooring using prepolished, water cut/ gang saw 19mm thick granite laid over bed of 20mm thick 1:4cm and Jointed with neat cment slurry mixed with pigment to match shade of granite slabs including laying POP on finished surface and cleaning the surface, including the cost of all materials and labours etc., complete as per specifications. -do- using Sira / silver grey granite / Multi Red granite of width not less than 1200mm. Ground Floor

137

-

334685.52

... More
Providing and laying flooring using prepolished,gang saw/ watercut 19mm thick granite laid with a bed of 20mm thick 1:4cm & jointed with neat cement slurry mixed with pigment to match shade of granite slabs inculding laying POP on finished surface and cleaning the surface, including the cost of all materials,mortar and labours etc., complete as per specifications. -do-using 19mm thick Raw Silk/ Black Pearl granite of width not less than 1200mm Ground Floor

47

-

138980.88

... More
Providing full nosing for 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work ,HOM etc., complete as per specification Ground Floor

350

-

102060

... More
KSRB 15-15.1 : Providing and applying painting in two coats with plastic emulsion paint of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete asper specifications. - with primer Ground Floor

3518

-

341949.6

... More
Terrace Floor

91

-

9238.32

... More
KSRB 15-15.1: Providing and applying painting in two coats with plastic emulsion paint of approved brand on ceiling / or sloping roof to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete asper specifications.- with primer Ground Floor

1279

-

6906.6

... More
Terrace Floor

7

-

68.04

... More
Providing and finishing external walls in two coats over one coat of 100% acrylic silicon glazed primer with antifungal paint for top coat of approved brand and shade to give an even shade after thoroughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications. Ground Floor

656

-

127526.4

... More
Terrace Floor

526

-

104526.72

... More
KSRB 15-18.2 : Providing and applying enamel metal paint two coats (excluding priming coat) over new steel or other metal surface brushing to give an even shade after cleaning oil, grease, dirt and other foreign matter, including cost of materials, labour, completeas per specifications.

92

-

9439.2

... More
KSRB 15-17.6 : Providing and applying painting two coats (excluding priming coat ) on new wood surface and / or wood based surface with enamel paint to give an even shade, cleaning the surface of all dirt, dust and foreign matter, sand papering including cost of materials, labour, complete as per specifications.

26

-

2723.76

... More
KSRB 15-17.12 : Providing and applying polishing with french polish on new wood surface and / or wood based surface to give an even surface after cleaning the surface of all dirt, dust and foreign matter, sand papered smooth, including cost of wood filler and materials, labour, complete as per specifications.

34

-

7417.44

... More
Providing applying two coats of wall putty to inside plastered walls and ceiling using white cement putty. Scrapping and levelling the surface using steel blade and preparing the surface even and smooth by using different grade sand papers, including cost of all materials, cost of labour and scaffolding etc., complete as per the specification Ground Floor

3518

-

296356.32

... More
Terrace Floor

91

-

8058.96

... More
KSRB-3.2: Providing and injecting chemical emulsion for Preconstructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits, with chloropyriphos emulsifiable concentrates of 20% concentration, including cost of chemical, diluting in water to one percent concentration, labour, HOM of equipments, complete as per specifications. (Plinth area of the building at ground floor only shall be measured ) Specification No. KBS : 3.2.6 / 3.2.7 Ground Floor

1826

-

209040.48

... More
ISOPROOF SEALER Providing waterproof treatment to roof slab using 2 coats of acrylic co polymer elastomeric ISOPROOF sealer & protector. The surface shall be prepared free of tar, dust, fungus, loose particles etc.,The surface shall be applied with basecoat of crystallization liquid and then ISOPROOF, wetting agent and liquid (1:1:6) over the prepared surface. In addition the surface shall be provided with polysulphide/ acrylic sealant to V groves, making haunch at junction of parapet and roof slab and at damaged portion using patching mortar to drain off rain water. Over this one coat of flexible cementatious membrane (FCM), Spreading 2 layers of 40 gsm non woven geotextile membrane as reinforcing material (over FCM) with one primer coat of ISOPROOF & applying second coat of ISOPROOF liquid over the primer coat - conforming to ASTM D 412 - 1992. The work shall be carried out as per the directions of the Engineer in charge. Standards & methodology : 1. Surface Preparation The surface shall be made free from all dirt, fungus, loose particles by using wire brush. The surface hall be cleaned with solvent like xylene, Toluene, Benzene, dilute hydro chloric acid. i) Cutting of ‘V’-Grooves : The V shaped grooves shall be cut along the location of all the visible cracks. The ‘V’-Grooves shall be of size 5mm as directed by the Engineer in charge. 2. Primary reduction of water permeability The concentrated crystallization liquid of specific gravity 1.09 is lightly diluted and applied on the prepared surface. The sodium acetate formed during the chemical reaction penetrates inside the pores of the concrete and reacts with water to form crystals to block the pores of the concrete, there by reducing water permeability. 3. Porosity and voids reduction (base Coat application) Applying wetting agent consisting of acrylic monomer, co-polymer liquid and crystallization liquid as base on the prepared surface and V groove and cracks etc. 4. Application of sealant / Patching mortar Cracks will be sealed using suitable sealant or patching mortar. These make them ideally suited for joint treatment. Its adhesion is very strong & binds with the building materials such as concrete, and take care of expansion and contraction in the structures. 5. Levelling course using Flexible Cementatious material A concrete mix in the ratio 1:1.5:3 (1:cement : 1.5 quartz powder :3 graded stone) is laid to make haunch at junction of parapet and roof slab and at damaged portions to drain off water.The factory made dry CEMENTATIOUS silica sand power consisting of dry cement mortar (1 cement : 4 silica sand) shall be mixed with additives like ISOPROOF chemical and acrylic polymer and water to arrive at workable consistency. The same shall be applied over the prepared surface to give even surface and act as base for geo- textile fabric. 6. Non woven Geo textile Fabric application: Two layers of Non-Woven Geo Fabric 40gsm (40=40=80gsm) shall be applied on FCM coating. Geo fabric shall be saturated with acrylic co polymer applied in wet condition. Over this layer, flexible monolithic membrane shall be laid by mixing single component ISO PROOF with water in the ratio of 1:1. 7. Primer Coat : A mixture of acrylic monomer (1:1) ISOPROOF & water mixed in proper proportion will be applied on the geotextile membrane.8. Final Coat: Application of a coat of ISOPROOF shall be applied at right angles to the primer coat and drying time is about 3 hours. The rate of completion of ISOPROOF for primer and final coat shall not be less than 1.25Kg per Sq meter

1185

-

1254204

... More
FOR TOILETS SUNK PORTIONSFOR TOILETS SUNK PORTIONS Providing INTEGRAL CRYSTALINE Waterproofing treatment to the sunken portion of Toilets. Using Crystalline Slurry of approved make @ 1.4kg per SQM in two coats (0.7 kg per sqm per coat) conforming to ASTM C 1202 & DINV 18998 standards. Methodology: 1. The first part consisting of grouting the porous slab area with non-shrink cementatious grout (if required). 2. The second part consisting of treating the cracks and construction joints by routing-out to a minimum 20mm x 20mm groove and treating it with crystalisation Mortar. First it is primed with crystalisation slurry and later filled with crystalisation mortar and later again a coat of crystalisation slurry. 3. The third part consisting of making required slopes at the interface joint of the toilet slab and masonry wall with crystalisation Mortar.. 4. The fourth part consisting of sealing / packing all joints of outlet pipes, etc. with CRYSTALISATION MORTAR 5. The fifth part consisting of providing and applying In-depth Crystalline Waterproofing System @ 1.4 kgs/sqm in 2 coats to permanently fix non-soluble crystalline growth throughout the capillary tracts and pores of concrete. The In-depth Crystalline waterproofing Material shall be applied by brushing as per manufacturer’s specification. on the entire toilet sunken slab and walls. Ground Floor

38

-

20520

... More
PROVIDING TRAPEZOIDAL PROFILED SHEET Providing and installing of pre painted Galvolume iron Trapezoidal profiled sheet of approved make 1060 mm width (1000 mm cover width), 28-30 mm crest height with crest distance of 200 mm c/c with 2 ribs at the centre for stiffening. The total coated thickness (TCT) of the sheet will be 0.47 mm +/- 0.02 mm tolerance Zinc-Alu Alloy coating AZ150 gsm as per ASTM 1397/A755-550 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 20-22 microns using self drilling/self tapping screws of 25 mm length, to be fixed over the existing purlins, rafters, channels and trusses.

40

-

29721.6

... More
WATER SUPPLY & SANITARY WORKS Earth work excavation for water supply and sanitary lines either in pits or in trenches 1.5m and below in width , in Hard soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50m.after breaking of clogs complete as per specifications.

83.6

-

40539.31

... More
Refilling of available earth around pipelines, cables in layers not exceeding 20cms in depth, compacting each deposited layer by ramming after watering with lead upto 50m and lift upto 1.5 mts including cost of all labor complete as per specifications.

75.24

-

9832.36

... More
KSRB13-8. : Providing and fixing to wall, ceiling and floor, medium density polyethylene pipes 6.00 kgs/sq.cm working pressure 20mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.1 / 13.9 for internal water supply connection KSRB 13-8.9- do - 75 mm dia

12

-

4224.96

... More
KSRB 13-8.9- do - 110 mm dia

173.16

-

84155.76

... More
KSRB 13-8.9- do - 160 mm dia

159.06

-

107709.07

... More
KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom 1.67m deep and 0.56m dia at top with table moulded non-modular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid separately )Specification No. KBS 12.4

2

-

52453.44

... More
KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6

10

-

2980.8

... More
Constructing brick masonry inspection chamber 600 x 600mm, and 450mm depth, (clear inside dimension) for single pipeline, using table molded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23kg and weight of frame 15 kg ) R.C.C. top slab with cement concrete 1:2:4 mix 20mm and downsize granite metal, foundation concrete 1:5:10 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labor charges, curing complete as per specifications.

12

-

110030.4

... More
.-do- 450x450mm, and 450mm depth, (clear inside dimension) for single pipeline, using table molded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) 600x600mm

4

-

22896

... More
.-do- 230x150mm and 450mm depth (clear inside dimension) for single pipeline, using table molded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) 230x150mm

8

-

13824

... More
Providing stoneware gully trap of approved quality and make fixing in CC 1:2:4 and plastering with CM 1:3 wherever necessary (Rate includes cost of all materials, fixtures and lead) for 15 cms x 10 cms

6

-

1814.4

... More
Providing and fixing PVC SWR Vent Cowl 110 mm (Supreme Make) including fixing with solvent complete.

8

-

1320

... More
Providing and fixing PVC 75mm size Nahani Trap of approved make (Supreme) conforming to ISI Specifications and construction of Cistern in CC 1:2:4 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot)

10

-

2700

... More
KSRB 11-6 : Providing and fixing white vitreous china clay, water closet European type ( Pedestal type, S-trap ) with black solid plastic seat and lid, C.P brass hinges, rubber buffers. 10 litre white glazed / vitreous china clay low level, flushing cistern ( all are approved make ) with fittings, C.I / M.S brackets, 40mm diameter flush bend with fittings and clamps, overflow arrangements with specials and 25mm mosquito proof coupling of approved design, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications.Specification No. KBS 11

16

-

89464.96

... More
KSRB 11-9.1 : Providing and fixing white vitreous china clay, flat back or half stall urinal basin of size 580x380x350mm with 5 litres P.V.C automatic flushing cistern, C.I / M.S brackets, standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps C.I dtrap with outlet grating and other couplings in C.P brass, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications.

6

-

19906.56

... More
KSRB 11-11.2 : Providing and fixing white vitreous china clay, flat back wash basin size 630x450mm white a single 15mm C.P brass pillar tap with C.I / M.S brackets, 32 mm C.P. Brass waste of standard pattern, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour Specification

9

-

29859.84

... More
Supply, fixing and testing of approved make Health faucet fixed to15mm dial CP angle stop cock with wall flange with 1 mtr pipe and wall hook etc complete.

16

-

26400

... More
KSRB13-6.2-2: Providing and fixing in position brass stop cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications.Specification No.KBS 13.2.2 / 13.3

31

-

4720.68

... More
KSRB13-6.1-2 : Providing and fixing in position brass bib cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications.Specification No.KBS 13.2.2 / 13.3

16

-

2989.44

... More
Providing gun metal pillar cocks 15mm dia of I class conforming to ISI specifications and fixing them in position as per directions including of cost of materials and fixtures and conveyance to spot.

9

-

2352.24

... More
KSRB 11-17.2 : Providing and fixing C.P. brass towel rail 600 mm length, 20mm dia with C.P brackets, fixed to wooden cleats with C.P. brass screws including cost of materials, labour complete as per specifications.

9

-

6551.28

... More
Providing and fixing C.P. brass towel ring of standard size , 20mm dia with c.p brackets, fixed to wooden cleats with c.p. brass screws including cost of materials, labor complete as per specifications. Jaquar / Cera / Hindware or approved equivalent

5

-

2250

... More
Supplying and fixing CP brass twin Robe hook fixed to wall / door with CP brass screws etc complete.

16

-

2400

... More
Supplying and fixing CP soap dish holder of approved shape and size fixed into wall with CM 1:3 etc complete.

9

-

2250

... More
Providing and fixing 7.5 cms x 15 cms dia NP grating 100mm dia

10

-

1620

... More
KSRB 11-15.1 : Providing and fixing 600x450mm bevelLead edge mirror of superior glass with 6mm hard board backing and fixed to wooden cleats with C.P screws, washers, including cost of materials, labour complete as per specifications.

9

-

11246.04

... More
Providing and fixing prepolished, water cut/ gang saw 19mm thick partitions of granite slabs including laying POP on finished surface and cleaning the surface, including the cost of all materials and labours etc., complete as per specifications. -do- using Sira / silver grey granite / Multi Red granite of width not less than 1200mm.

3.6

-

10190.45

... More
Providing and fixing Chlorinated Poly Vinyl Chloride (CPVC) pipes confirming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mt spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and cost of cutting chases and making good the same including testing of joints complete (Concealed work including cutting chases and good the walls etc) For 15mm nominal OD pipe

94

-

20913.12

... More
For 20mm nominal OD pipe

112

-

28425.6

... More
For 25mm nominal OD pipe

72

-

22783.68

... More
Providing and fixing Chlorinated Poly Vinyl Chloride (CPVC) pipes confirming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mt spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete ( work exposed on wall) For 20mm nominal OD pipe

160

-

27129.6

... More
For 25mm nominal OD pipe

288

-

60963.84

... More
For 50mm nominal OD pipe

110

-

55242

... More
Providing and fixing in position brass ball valve high or low pressure with plastic float of approved quality 25mm nominal bore including cost of all materials, labor charges, HOM equipment with all leads complete as per specifications

13

-

7202.52

... More
Providing and fixing unplasticisied PVC connection pipe with brass union 20mm nominal bore 450mm length of PVC connection including cost of all materials labor charges, HOM equipment with all leads complete as per specifications.

9

-

2391.12

... More
Providing and fixing in position brass gate valve with CI wheel of approved quality (screwed end) nominal bore including cost of all materials, labor charges, HOM equipment with all leads complete as per specifications. For 20mm nominal bore

6

-

2177.28

... More
For 25mm nominal bore

4

-

1939.68

... More
For 50mm nominal bore

2

-

3756.24

... More
KSRB 13-11.1 : Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.(For 1000 litre capacity) Specification No.KBS 13.22 Triple layered Sintex/ Kaveri / Ganga or approved equivalent

5

-

36871.2

... More
Making Wall bores in Stone Masonry upto .45m width for soil / water pipe including necessary scaffolding etc complete

10

-

1360.8

... More
Making Wall bores in Brick Masonry upto .45m width for soil / water pipe including necessary scaffolding etc complete

2

-

272.16

... More
Making Wall bores in Cement Concrete upto 0.45m width for soil / water pipe including necessary scaffolding etc complete

6

-

816.48

... More
Providing and laying reinforced cement concrete pipe NP3 for culverts including pointing ends, and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing complete as per specifications. Specifications. No. KSRB 1000, 2300 MOST Specification No.1000 / 2300 - 450mm. dia

30

-

83689.2

... More
SEPTIC TANK : KSRB 2-2.2 : Earthwork excavation by manual means for foundation of buildings, culverts, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in hard soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications. No. KBS 2.1(b) / 2.3.5

163

-

79041.96

... More
KSRB 2.3 : Filling available excavated earth ( excluding rock ) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as per specifications.

49

-

10636.92

... More
KSRB 4-1.3 : Providing and laying in position plain cement concrete of mix 1:4:8 with OPC cement @ 180kgs, with 40mm and down size graded granite metal coarse aggregates @ 0.85 Cum and fine aggregates @ 0.57 Cum machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation and plinth, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2

5

-

28629.15

... More
KSRB 4-1.6 ; Providing and laying in position plain cement concrete of mix 1:2:4 with cement @240Kgs. with 20mm and down size graded granite metal coarse aggregates @ 0.878 cum and fine aggregates @ 0.459 cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation,plinth and cills, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2. Upto 3.50m Level

11

-

67576.52

... More
Providing and Constucting granite / trap / rubble stone vertical stenning with open joint for soak pit wall, including cost of materials, labour, scaffolding etc complete

17

-

70720

... More
KSRB 4.2.2: Providing and laying in position reinforced cement concrete of mix M20 with OPC cement @ 320 kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.69cum and fine aggregates @ 0.460cum, with superplastisiser @ 3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15cms thick, vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, wall (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, bed blocks, anchor blocks, & plinths etc., including cost of all materials, labour, HOM of machinery, curing complete as per specification. Specification No. KBS 4.1, 4.6.

30

-

191978.4

... More
KSRB 4-6.4: Providing and removing centering , shuttering , strutting, propping etc., and removal of form work for vertical surfaces such as walls at any thickness, including attached pilasters, buttresses, plinth cills and string courses cost of all materials, labour complete as per specification. Speco\ification Mo.KBS 4.6.2

181

-

69981.84

... More
KSRB 4.2.2: Providing and laying in position reinforced cement concrete of mix M20 with OPC cement @ 320 kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.69cum and fine aggregates @ 0.460cum, with superplastisiser @ 3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15cms thick, vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, wall (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, bed blocks, anchor blocks, & plinths etc., including cost of all materials, labour, HOM of machinery, curing complete as per specification. Specification No. KBS 4.1, 4.6. (For Baffle Walls)

12

-

76791.36

... More
Providing Primary T.M.T. steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. Upto 3.50m Level. TMT bars Fe 500

3

-

248752.5

... More
KSRB 15-3.10 : Providing 20mm thick cement plaster in single coat with cement mortar 1:3 to stone masonry & concrete surfaces including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labor, curing complete as per specifications.

112

-

36500.8

... More
Waterproofing of RCC Terrace / podium slab / toilet / utilities / water retaining structure by preparing the surface by chipping and cleaning and Grouting of Honey comb, voids,cracks / construction joints with cement slurry (1kg cement added in 10 ltr of water) added with 100gm of inorganic accelerator, followed by spraying of liquid biological modified alkaline earth silicates @ 0.40 ltr per sqm on whole surface to reduce the micro porosity and allowing it to dry, curing the surface for the silicates to penetrate deeper into the concrete and spraying waterproofing impregnate liquid containing silane and silanol linear copolymer @ 0.50 ltr per sqm and finally applying polymer slurry made out of cross linked acrylic / styrene / butadiene & cement in the ratio of 1:0.1, @ 0.50kg/sqm on the whole surface, including all labour charges tools and equipments, all complete as per the specification

112

-

63624.96

... More
Providing and filling Brick bats of size 25 to 100mm for soak pit including cost of materials, labour etc complete.

10

-

10400

... More
Providing and filling Pea size gravel / 6mm and down stone grit in rainwater harvesting structure and soak pit including cost of materials, labour etc complete.

12

-

11700

... More
Providing and fixing 450X200MM size Stone Beam for support to stone slabs including fixing over rubble stenning walls in 1:2:4 with scaffolding, cost of materials, labour, curing etc complete,.

9

-

9360

... More
KSRB 8.1 : Providing and fixing in position stone slab roofing 10 to 12 cms thick laid to line and level over wooden rafters or R.C.C. battens, pointing exposed joints with cement mortar 1:4 including cost of materials, labour, curing complete as per specifications. (wooden rafters and R.C.C. battens to be paid seperately) Specification No. KBS

16

-

20010.24

... More
Providing and fixing CI Manhole frame and cover of size 600X600MM including fixing in 1:3:6 proportion with scaffolding, curing etc complete,. 50 Kg wt

3

-

14820

... More
KSRB13-8. : Providing and fixing to wall, ceiling and floor, medium density polyethylene pipes 6.00 kgs/sq.cm working pressure 20mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.1 / 13.9 for internal water supply connection

25

-

16929

... More
KSRB 13-8.9- do - 75 mm dia

10

-

3520.8

... More
KSRB 13-8.9- do - 110 mm dia

10

-

4860

... More
Providing and fixing sand cast iron soil waste and vent pipes 100mm dia with spun yarn soaked in cement slurry and cement mortar 1:2 including cost of all materials, labour,testing complete as per specifiations.

5

-

7800

... More
Providing and fixing PVC SWR Vent Cowl 110 mm (Supreme Make) including fixing with solvent complete.

2

-

312

... More
KSRB 12-6.3 : Providing cast iron footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6

10

-

2548.8

... More
Providing and fixing in position brass ball valve high or low pressure with plastic float of approved quality 25mm nominal bore including cost of all materials, labor charges, HOM equipment with all leads complete as per specifications

2

-

1108.08

... More
UNDERGROUND SUMP- 10000 LITERS : KSRB 2-2.2 : Earthwork excavation for foundation of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in hard soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. after breaking of clods complete as per specifications. specification. No. KBS 2.1(b) / 2.3.5

12

-

5819.04

... More
KSRB 4-1.3 : Providing and laying in position plain cement concrete of mix 1:4:8 with OPC cement @ 180kgs, with 40mm and down size graded granite metal coarse aggregates @ 0.85 Cum and fine aggregates @ 0.57 Cum machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation and plinth, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2

1

-

5725.83

... More
KSRB 4.2.1: Providing and laying in position reinforced cement concrete of design mix M25 with OPC cement @ 340 kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.70cum and fine aggregates @ 0.47cum, with superplastisiser @ 3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15cms thick, vibrated for all works in foundation plinth and ground floor level for roof slabs, staircase, lintless, retaining walls, return walls, wall (any thickness) including attached plasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing complete as per specification. UPTO 3.50M lEVEL

2

-

13368.68

... More
KSRB 4.2.7 : Providing and laying in position reinforced cement concrete of design mix M25 with OPC cement @ 340kgs, with 20mm and down size graded granite metal coarse aggregates @0.70cum and fine aggregtes @ 0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintels and plinth beams retaining walls, return walls, walls (any thickness) including attached pilasters, columns, lintles, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6

1

-

6935.98

... More
KSRB 4-6.4 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for vertical surface such as walls at any thickness, including attached pilasters, buttresses, plinth and string courses cost of all materials labour complete as per specifications. Specification No. KBS 4.6.2 Upto 3.50m Level

37

-

14305.68

... More
KSRB 4-6.2 : 'Providing and removing centering, shuttering, strutting, propping etc., removal of form work for flat surface such as suspended floors,Slab roofs, landings, balconies and likes, thickness upto 200 mm including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2. Upto 3.50m Level

7

-

3024

... More
KSRB15-3.5 :Providing 15mm thick cement plaster in single coat with cement mortar 1:4, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. Upto 3.50m Level.

19

-

4671.53

... More
KSRB15-3.8 :Providing 18mm thick sand finish cement plaster in single coat with cement mortar 1:4, to brick masonry including rounding off corners: Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. Upto 3.50m Level.

19

-

5526.53

... More
Waterproofing of RCC Terrace / podium slab / toilet / utilities / water retaining structure by preparing the surface by chipping and cleaning and Grouting of Honey comb, voids,cracks / construction joints with cement slurry (1kg cement added in 10 ltr of water) added with 100gm of inorganic accelerator, followed by spraying of liquid biological modified alkaline earth silicates @ 0.40 ltr per sqm on whole surface to reduce the micro porosity and allowing it to dry, curing the surface for the silicates to penetrate deeper into the concrete and spraying waterproofing impregnate liquid containing silane and silanol linear copolymer @ 0.50 ltr per sqm and finally applying polymer slurry made out of cross linked acrylic / styrene / butadiene & cement in the ratio of 1:0.1, @ 0.50kg/sqm on the whole surface, including all labour charges tools and equipments, all complete as per the specification

19

-

10793.52

... More
KSRB 4.9.2 : Providing T.M.T. steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. Upto 3.50m Level.

1

-

82917.5

... More
Providing and fixing CI Manhole frame and cover of size 600X600MM including fixing in 1:3:6 proportion with scaffolding, curing etc complete,. 50 Kg wt

2

-

9880

... More
RAIN WATER HARVESTING : Providing and Constructing Rainwater harvesting collecting points done with including excavation and refilling to insert RCC precast rings of 1.50 m dia and depth of 0.45m of 8 nos, with filling 40mm metal granite, 20mm metal granite and sand of height 1.10m individually with covering the top surface using RCC precast Slab as per design and drawings, filling the sides with boulders and available earth and shifting the excess earth outside the site premises.

2

-

40000

... More
Providing and fixing Rain water Filters of Rain top make of 2000 sft capacity.

6

-

48000

... More
Point wiring using copper wire without switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box Item No 2.2.1 & Page No 5

19

-

3040

... More
Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box Item No 2.2.2 & Page No 5

39

-

9750

... More
Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box Item No 2.2.3 & Page No 5

71

-

26625

... More
Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to out let via switches Item No 2.2.4 & Page No 5

82

-

38950

... More
Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches box Item No 2.2.5 & Page No 5

5

-

3375

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall : 1-3Way Item No 3.4.1 & Page No 9

79

-

7505

... More
4-5Way Item No 3.4.2 & Page No 9

10

-

1050

... More
6Way Item No 3.4.3 & Page No 9

19

-

2375

... More
8Way Item No 3.4.4 & Page No 9

12

-

1740

... More
10-12Way Item No 3.4.5 & Page No 9

61

-

10065

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box..1-3Module Item No 3.5.1 & Page No 9

79

-

8690

... More
b) 4Module Item No 3.5.2 & Page No 9

10

-

1250

... More
c) 6Module Item No 3.5.3 & Page No 9

19

-

3325

... More
d) 8Module Item No 3.5.4 & Page No 9

12

-

2400

... More
e) 10Module Item No 3.5.5 & Page No 9

31

-

7130

... More
f) 12Module Item No 3.5.5 & Page No 9

30

-

6900

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. -6Amps one Way Item No 3.6.1 & Page No 10

375

-

26250

... More
6Amps Two way Item No 3.6.2 & Page No 10

2

-

190

... More
6Amps 3way socket Item No 3.6.3 & Page No 10

159

-

16695

... More
Steeped fan Regulator Item No 3.6.4 & Page No 10

69

-

20010

... More
16Amps one way switch Item No 3.6.8 & Page No 10

30

-

3450

... More
6Amps Bell push Item No 3.6.9 & Page No 10

3

-

288

... More
32Amps DP switch Item No 3.6.10 & Page No 10

4

-

728

... More
6/16Amps universal socket Item No 3.6.11 & Page No 10

34

-

5508

... More
TV/Telephone socket Item No 3.6.12 & Page No 10

30

-

2370

... More
RJ 45/IO Outlet CAT - 6 Item No 3.6.13 & Page No 10

48

-

9360

... More
Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. Ding Dong bell Item No 13.2.1 & Page No 71

3

-

660

... More
Supplying And Fixing Metal Fan Box with Round Hook. Item No 1.12 & Page No 3

69

-

5865

... More
Supplying and fixing of metal clad industrial plugs and sockets. 2pole+earth 250V PLUG 20 Amps Item No 3.13.2 & Page No 10

2

-

408

... More
3pole+earth 440V PLUG 30 Amps Item No 3.13.4 & Page No 10

2

-

680

... More
2pole+earth 250V SOCKET 20 Amps Item No 3.13.6 & Page No 10

2

-

480

... More
3pole+earth 440V SOCKET 30 Amps Item No 3.13.8 & Page No 10

2

-

550

... More
Concealed Conduit System: Supplying heavy gauge PVC conduit pipe ……mm dia ....... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary : 19mm dia 2mm thick Item No 1.2.1 & Page No 2

1075

-

43000

... More
25mm dia 2mm thick Item No 1.2.2 & Page No 2

3785

-

200605

... More
Groove cutting : Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.19mm dia 2mm thick Item No 1.3.1 & Page No 2

460

-

23460

... More
b) 25mm dia 2mm thick Item No 1.3.2 & Page No 2

1125

-

60750

... More
CIRCUITS & MAINS : Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5sqmm Item No 2.3.2 & Page No 5

6175

-

126587.5

... More
2.5sqmm Item No 2.3.3 & Page No 6

3325

-

106400

... More
4sqmm Item No 2.3.4 & Page No 6

1750

-

78750

... More
6sqmm Item No 2.3.5 & Page No 6

1000

-

70000

... More
Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. Double Door : 6way TP &N Item No 5.18.10 & Page No 28

3

-

9990

... More
Double Door 4Way TP& N Item No 5.18.9 & Page No 28

2

-

5300

... More
Double Door 8Way TP& N Item No 5.18.11 & Page No 28

2

-

7700

... More
Single Door 12Way SP& N Item No 5.18.4 & Page No 28

2

-

2420

... More
Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board.. : 63Amps 4 pole Item No 5.20.4 & Page No 28

2

-

6400

... More
40 Amps 4 pole Item No 5.20.3 & Page No 28

8

-

22400

... More
32-40 Amps 2 pole Item No 5.20.2 & Page No 28

8

-

20000

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.. 5-32A SP MCB Item No 5.17.1 & Page No 27

72

-

31248

... More
5-32A DP MCB Item No 5.17.4 & Page No 27

12

-

10908

... More
5-32A TP MCB Item No 6.16.7 & Page No 47

12

-

20580

... More
40-63A TP MCB Item No 6.16.9 & Page No 47

15

-

35955

... More
LIGHT FIXTURES AND FANS : Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V @ 50/60Hz & Power factor >0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x2'- 9/10W Item No 12.3.1 & Page No 64

6

-

1500

... More
LED light fighting 1 x4'- 20/22W Item No 12.3.2 & Page No 64

135

-

50625

... More
Supplying & Fixing of 70-150 Watts lamp holder 2 Pin Item No 13.46 & Page No 76

5

-

530

... More
Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V @ 50/60Hz & Power factor >0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED square or round down light 5-6W Item No 12.5.1 & Page No 65

5

-

2520

... More
Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V @ 50/60Hz & Power factor >0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W Item No 12.5.2 & Page No 65

40

-

30720

... More
LED square or round down light 10-12W Item No 12.5.1 & Page No 65

5

-

3840

... More
Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI> 70%. efficacy >100 lumen per watt, 120degree beam spread, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2' / 1' x 4' 34 -36watt Item No 12.6.2 & Page No 65

20

-

104000

... More
Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. Item No 7.1 & Page No 46

3

-

3600

... More
Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300mm) Item No 7.2.1 & Page No 46

10

-

21000

... More
Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model Item No 7.3.1 & Page No 46

69

-

144210

... More
Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>130lm/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 25watts Item No 12.8.1 & Page No 67

13

-

23920

... More
Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. Item No 14.8 & Page No 80

69

-

10350

... More
Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame Item No 14.11 & Page No 80

13

-

8450

... More
Supplying and Fixing 50mm class A GI pipe up to 4.5 Mtrs. long with a reducing collar of 50x40mm to which, an extension of 250 mm pipe is fixed for 125 or 250/400 watts MV / sodium vapour street light fitting, using suitable clamps, bolts ,nuts, and wiring using suitable capacity wires. Item No 14.3 & Page No 79

13

-

26455

... More
Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. Item No 14.5 & Page No 79

13

-

2275

... More
Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2Pair Item No 9.2.2 & Page No 54

1500

-

21750

... More
5 Pair Item No 9.2.5 & Page No 54

1250

-

60000

... More
50 Pair Item No 9.2.7 & Page No 54

100

-

29200

... More
Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. Item No 9.3 & Page No 54

100

-

3500

... More
Supplying and drawing UTP-CAT 6E LAN cable. Item No 9.1 & Page No 54

2500

-

72500

... More
Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 50 Pair Item No 9.13.4 & Page No 55

3

-

1650

... More
MAIN PANEL : Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 250Amps 4Pole 35kA Item No 5.14.11 & Page No 27

2

-

34200

... More
Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)250 Amps item no 5.12.5 pno 26

1

-

20400

... More
Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. Item No 5.21 & Page No 28

1

-

7700

... More
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency,Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. Item No 5.33 & Page No 29

1

-

7750

... More
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound. Item No 5.34 & Page No 29

3

-

1404

... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C. Item No 5.38 & Page No 29

3

-

1290

... More
Supplying amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminium Strips Item No 5.40.2 & Page No 30

2

-

5700

... More
OutGoings: Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 63A TPN MCB Item No 5.17.9 & Page No 27

7

-

16779

... More
32A DP MCB Item No 5.17.4 & Page No 27

3

-

2727

... More
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 125Amps 4Pole 25kA Item No 5.14.8 & Page No 27

1

-

8250

... More
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75x75x6mm Item No 5.41.3 & Page No 30

24

-

11040

... More
Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.14SWG Item No 5.42.1 & Page No 30

115000

-

46000

... More
Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N.F. screws. Item No 3.9 & Page No 10

175000

-

42000

... More
Supplying & Fixing Chemical earthling for grounding. Conduits, IC cutouts & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 10ft copper bonded rod with backfill compound Item No 6.19.3 & Page No 44

6

-

43560

... More
Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip Item No 6.3.1 & Page No 40

60

-

4500

... More
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 : 4Core 10Sqmm cable Item No 6.4.2 & Page No 40

50

-

6500

... More
4Core 16Sqmm cable Item No 6.4.4 & Page No 40

75

-

11250

... More
3.5Core 150Sqmm Item No 6.4.11 & Page No 41

150

-

108000

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct : 6sqmm to 16sqmm Item No 6.5.1 & Page No 41

100

-

1188

... More
95sqmm to 150sqmm Item No 6.5.3 & Page No 41

110

-

2310

... More
On wall/structure 6sqmm to 16sqmm Item No 6.5.6 & Page No 41

25

-

750

... More
95sqmm to 150sqmm Item No 6.5.8 & Page No 41

40

-

1600

... More
Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) : in soil ( ordinary) Item No 6.6.1 & Page No 41

75

-

5700

... More
Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable. Item No 6.7 & Page No 41

75

-

7500

... More
Providing and laying in position 100mm dia stone ware pipe in exisitng trench. Item No 6.8 & Page No 41

20

-

4300

... More
Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV.80mm Item No 6.9.4 & Page No 42

3

-

2064

... More
Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KVclass (metal only) 25mm dia Item No 6.11.2 & Page No 42

4

-

336

... More
75mm dia Item No 6.11.7 & Page No 42

2

-

992

... More
Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 10Sqmm Long Barrel Item No 6.17.5 & Page No 43

8

-

64

... More
16Sqmm Long Barrel Item No 6.17.6 & Page No 43

8

-

99.52

... More
95Sqmm Long Barrel Item No 6.17.11 & Page No 43

2

-

290

... More
150Sqmm Long Barrel Item No 6.17.13 & Page No 43

6

-

1410

... More
Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary GI bolts/nuts and washers or welding as required. 300x50mm Item No 6.16.2 & Page No 43

5

-

2650

... More
Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 10 KVA ON LINE UPS Item No 10.03.5 & Page No 57

1

-

118800

... More
Supplying, installation, testing & commissioning of 12Volts ..AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type. 100 AH capacity. .Item No 10.04.4 & Page No 57

12

-

188400

... More
48 port 10/100/1000 Switch .Item No 9.09.9 & Page No 54

2

-

37400

... More
BOREWELL : Sinking Borewell of 165mm dia clear using super fast hydraulic rif of capacity 250 PSIG and above 900 CMF and above in all strata including over burden upto 20 m. fixing of casing pipes, collars and cap with necessary cuttung, threading and welding including transportation of rig and supporting vehicles, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one house (excluding cost of casing pipes, collars, cap etc.,) a) 0 to 50 mts

53

-

14575

... More
b) 50 to 100 mts

53

-

18656

... More
c) 100 to 150 mts

53

-

21889

... More
d) 150 to 200 mts

53

-

26235

... More
e) 200 to 250 mts

53

-

30634

... More
Supplying and fixing of 175mm dia 3mm thick. Normal bore medium black ERW casing pipes (B-Class) black electric resisting containers welded MS tubes medium grade confitming to IS 1239/1979 (part-1) Amendment 1 to 5 and in random length of 4 to 7 mtrs. With all lead and lifts.

48

-

63360

... More
a) Collar

11

-

1518

... More
b) Cap

2

-

276

... More
Supplying and fixing 75mm int dia HDPE pipe16kg/Sq cmwith stainless steel end fittings etc complete.

97

-

45396

... More
Supplying and fixing stainless steel submercible pump set of 5HP capacity of approved make.

2

-

66000

... More
Supplying and laying 3 core flat submercible cable 6.0 sqmm. Item No 91 & Page No X1

237

-

28677

... More
Providing and fixing Electronic Control panel board with MCB's

2

-

26400



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.