University Of Agricultural Sciences Tender

View complete overview of UAS Tender

University Of Agricultural Sciences - UAS Tender

NA
Opening Date10 Mar 2021
Closing Date20 Mar 2021
Tender Amount₹ 56,87,424 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Annual Maintenance as per original equipment manufacturers standards, by taking preventive measures as per the equipment manufacturers manual, so that the system is functioning properly. - cabinet type, modular ceiling suspended double skin air handling units with 25/ 40 mm thick panels complete with Fan section with forward curved low noise DlDW centrifugal fan (fan noise not to exceed 76dBa), fan motor, drive set with V-Belt drive/ direct drive, belt guard, limit switch & light point with marine lamp with cover for the fan motor section, access door, Coil section with cooling coil, stainless steel drain pan, filter section with filters suitable for 10 micron particle size, 90% efficient filters, with GI/Aluminium dampers for outlets with flexible connection with Zip for duct connection. The chiIled water entering temperature to be maintained at 7.0degC and the ADP to be achieved shall be 11.6 degC. The AHU is capable of handling air at static pressure of 25mm WC, and capacitites -(7500 CFM ). -Cleaning the filters regularly, Check electrical connections, power supply, water leakage, viberations, noise level, motor-body over heating, lubricating moving parts, belt drive adjustments etc.,

2

-

19008

... More
Annual Maintenance as per original equipment manufacturers standards, by taking preventive measures as per the equipment manufacturers manual, so that the system is functioning properly. -TOILET EXHAUST SYSTEMS: cabinet type exhaust air AHU with centrifugal blower, drive motor, belt drive package, damper and canvass connection, GI weather hood cover sheets, vibration isolation pads,etc Air qnty St.Pr. MOTOR (CFM) (mm WG) KW (a) 6500 . -Cleaning the filters regularly, Check electrical connections, power supply, water leakage, viberations, noise level, motor-body over heating, lubricating moving parts, belt drive adjustments etc.,

2

-

15840

... More
Annual Maintenance as per original equipment manufacturers standards, by taking preventive measures as per the equipment manufacturers manual, so that the system is functioning properly. -TOILET EXHAUST SYSTEMS: cabinet type exhaust air AHU with centrifugal blower, drive motor, belt drive package, damper and canvass connection, GI weather hood cover sheets, vibration isolation pads,etc Air qnty St.Pr. MOTOR (CFM) (mm WG) KW (4500 CFM ). -Cleaning the filters regularly, Check electrical connections, power supply, water leakage, viberations, noise level, motor-body over heating, lubricating moving parts, belt drive adjustments etc.,

2

-

12672

... More
Annual Maintenance as per original equipment manufacturers standards, by taking preventive measures as per the equipment manufacturers manual, so that the system is functioning properly. -TOILET EXHAUST SYSTEMS: cabinet type exhaust air AHU with centrifugal blower, drive motor, belt drive package, damper and canvass connection, GI weather hood cover sheets, vibration isolation pads,etc Air qnty St.Pr. MOTOR (CFM) (mm WG) KW (1800 CFM ). -Cleaning the filters regularly, Check electrical connections, power supply, water leakage, viberations, noise level, motor-body over heating, lubricating moving parts, belt drive adjustments etc.,

1

-

6336

... More
Annual Maintenance as per original equipment manufacturers standards, by taking preventive measures as per the equipment manufacturers manual, so that the system is functioning properly. -TOILET EXHAUST SYSTEMS: cabinet type exhaust air AHU with centrifugal blower, drive motor, belt drive package, damper and canvass connection, GI weather hood cover sheets, vibration isolation pads,etc Air qnty St.Pr. MOTOR (CFM) (mm WG) KW (1000 CFM ). -Cleaning the filters regularly, Check electrical connections, power supply, water leakage, viberations, noise level, motor-body over heating, lubricating moving parts, belt drive adjustments etc.

1

-

4224

... More
Annual Maintenance to Scroll Based 8.5 TR Air cooled condensing unit complete with scroll compressor, aircooled copper tube aluminum finned condensing coil, propeller type fans, starters, controls, etc. The scope shall include the cost of check refrigerant piping, pressure testing, electrical cabling etc. 6nos x 8.5TR =51 TR

51

-

67320

... More
Annual Maintenance to Scroll Based 2 TR Air cooled condensing unit complete with scroll compressor, aircooled copper tube aluminum finned condensing coil, propeller type fans, starters, controls, etc. The scope shall include the cost of check refrigerant piping, pressure testing, electrical cabling etc. 14nos x 2TR =28 TR

28

-

36960

... More
Annual Maintenance to Scroll Based 1.5 TR Air cooled condensing unit complete with scroll compressor, aircooled copper tube aluminum finned condensing coil, propeller type fans, starters, controls, etc. The scope shall include the cost of check refrigerant piping, pressure testing, electrical cabling etc. 2nos x 1.5TR =3---- It includes the cost of all approved materials, lead lift and transportation etc., The work should be carried out as per the directions of the Engineer in Charge of the work.Make:blue star 2 Nos.1.5TR = 3TR

3

-

3960

... More
II) DIESEL GENERATOR: Annual Maintenance and Supplying, fixing of radiator drive belts for DG Sets . a) 500 KVA DG Set .. It includes the cost of all approved materials, lead lift and transportation etc., The work should be carried out as per the directions of the Engineer in Charge of the work.

4

-

11440

... More
Annual Maintenance of caliberation and Fine Tuning of fuel pumps of 500 KVA DG Set. 2 Nos.

2

-

20240

... More
Annual Maintenance of caliberation and Fine Tuning of fuel injectors of 500 KVA DG Set 2 Nos.

2

-

24288

... More
Annual Maintenance and servicing of Diesel Engine for replacement of following items such as old oil from crank case, cleaning of crank case, cleaning the engine,changing of lube oil filters, fuel, filters including tuning up engine and general "B" checkup, complete as per manufactures standards. 500 KVA DG Set 2Nos.

4

-

100672

... More
Annual Maintenance Charges for servicing and lubrication of Alternator for following DG Set . 500 KVA DG Set

2

-

10296

... More
Annual Maintenance Charges for Servicing with replacing carbon brushes to self starter for the following DG sets . 500 KVA DG Set 2 Nos.

2

-

13552

... More
Annual Maintenance of water temperature safety switch for 500KVA DG set it includes the cost of all approved materials lead lift and transportation etc.

2

-

5148

... More
Annual Maintenance and Supply, fixing of Lube oil pressure safty switch. It includes the cost of all approved materials lead lift and transportation etc..

2

-

6160

... More
Annual Maintenance of Coolent water sensor. It includes the cost of all approved materials lead lift and transportation etc..

2

-

5772

... More
Annual Maintenance of Diode kit for alternator. It includes the cost of all approved materials lead lift and transportation etc.. a) 500 KVA DG Set

2

-

9944

... More
Annual Maintenance with Supplying of bearing grease.

4

-

1408

... More
Annual Maintenance with Supplying & filling of radiator water coolant solution for 2 x 500 kva DG Set .

44

-

13552

... More
Annual Maintenance with Supplying of 15/40 multi grade Engine lubricating oil. 2 x 500Kva DG Set---- It includes the cost of all approved materials, lead lift and transportation etc., The work should be carried out as per the directions of the Engineer in Charge of the work.

266

-

61180

... More
III) FIRE FIGHTING AND FIRE HYDRANT SYSTEM: : Annual maintenance by ensuring Power supply-voltage & current, equipment temperature, noise level, water flow, terminations, vibrations, & other essential parameters are maintained at normal levels by taking preventive measures as per the manufacturer's standards so that the equipment is functioning smoothly . The work should be carriedout as per the directions of the Engineer in Charge of the work. Electrical motor driven main pump of75 HP horizontal centrifugal end suction type with gland packing and capable to deliver 2850LPM at 120MWC to ensure a minimum pressure of 3.5 Kg/Sqcm at the farthest or topmost hydrant / sprinkler. Fire pump shall have C.I. casing, CS diffusers, bronze impeller (hard finished and dynamically balanced) and S.S. (304) Shaft with mechanical seal. The installation is complete with necessary pressure gauge with gun metal shut off cock on delivery side. The pump is coupled to Squirrel cage induction motor, TEFC type suitable for operation on 415 volts, 3 phase 50 HZ A.C supply, for the above pump with synchronous speed of 1800 RPM, conforming to IP 55 protection & class F insulation. The motor shall conform to IS 325-1978 (up to date) and complete set mounted on common base frame, coupled to Vibration isolator, flexible couplings and Foundation bolts etc.

1

-

23320

... More
Annual Maintenance of Operational maintenance for fire pumps by ensuring Power supply-voltage & current, equipment temperature, noise level, water flow Flow, terminations, viberations, & other essential parameters are maintained at normal levels by taking preventive measures as per the manufacturer's standards so that the equipment is functioning smoothly .The work should be carriedout as per the directions of the Engineer in Charge of the work. The pump is coupled to suitable 75HP of Diesel engine radiator water cooled type with speed of 1500 RPM and complete set shall be mounted on common base frame. Batteries & battery leads with stand, Fuel tank ( for 6 Hrs. operation ) with stand & glass gauge , Fuel piping with valves. The radiator water cooling piping , coupling gaurd and other standard accessories,flexible couplings and foundation bolts, etc. complete. Pump is capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head will not exceed 120% of rated head.heat exchanger with necessary piping connections & fittings, flexible coupling, coupling guard & exhaust pipe connection complete.

1

-

20680

... More
Annual maintenance by ensuring Power supply-voltage & current, equipment temperature, noise level, water flow Flow, terminations, vibrations, & other essential parameters are maintained at normal levels by taking preventive measures as per the manufacturer's standards so that the equipment is functioning smoothly .The work should be carriedout as per the directions of the Engineer in Charge of the work. Electrical motor driven 10HP JOCKEY pump of horizontal centrifugal end suction back pull out type with gland packing and capable to deliver 180LPM at 45 mts head with all the necessary accessories viz. Pressure gauges etc. operating on 3 Ph 50 Hz, 400/440V AC supply including base frame foundation, bolts etc. complete. The pump is coupled to TEFC motor of suitable HP with speed of 2900RPM and complete set shall mounted on common base frame. The coupling and coupling gaurd RCC foundation (as recommended by manufacturer) and Foundation bolts, etc complete.

1

-

5192

... More
Annual Maintenance of Gun Metal fire brigade connection (suction collecting head) consisting of 4 Nos. 63 mm dia instantaneous type male couplings with built-in check valves, 1 No. 150 mm dia sluice valve, (1 No. 150 mm dia non-return valve) and 150 mm dia flanged outlet complete with bolts, nuts and rubber insertions as required and as per IS standards, complete as required .

1

-

1584

... More
Annual maintenance by ensuring all opening & closing of Strainer & foot valves, brass ball valve, CI butterfly valves, dual plate CI wafer type check valve, be operated smoothly, water flow, & other essential parameters are maintained at normal levels, clean & remove the silt collected in ''Y''-stainers, by taking preventive measures as per the manufacturer's standards so that the equipment is functioning smoothly . The entire system shall be checked for operations every 30-days, the water shall be removed from the circuit & fresh water be made to flow in the Hydrant circuit so that the corrosion be minimised,The work should be carriedout as per the directions of the Engineer in Charge of the work.

1

-

105600

... More
Annual maintenance of Control panel for fire hyndrant system pumps motor control centre is fabricated out of 14 gauge CRCA sheet steel in cubicle in 3b formation with reinforcement of suitable size angle iron, channel ‘T’ sections irons and/or flats wherever necessary. Cable gland plates is provided on top as well as at the bottom of the panels. Panels be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks also provided in case of large panels. Approval be taken for each panel before fabrication. Cadimium plated hardware shall be used in fabrication of panels. MCC-1 (Fire Panel), INCOMING: a. 1 No. 400 amps 4 pole mechanical interlocked incoming MCCB complete with the following: ii. 0-400 amps 96 x 96 mm square ammeter with 400/5 amps 15 VA CL:1 CT's and selector switch 1 Set, iii. Phase indicating lamps shall be protected by 2 amps SP MCB 6 Sets, b. Aluminium bus bar sleeves type, rated at 600 amps for three phase & neutral phase bus bar shall have maximum current density of 1 amps per sq.cm. and the neutral bus bar of not less than 50% capacity. OUTGOING: c. 2 Nos. 250 amps TPN MCCB outgoing feeders with 75HP/56KW STAR DELTA starters out going feeders to Hydrant / Sprinkler pump motor. The compartment shall contain CT operated ammeter of 0-250 amps range with selector switch auto / manual selector switch and indicating lamp with MCBs for `ON'/OFF`TRIP' status of motor. d. 2 Nos. 60 amps TPN MCCB, 15 KW Direct online starter with single phase preventer and outgoing feeder to jockey pump motor. The compartment contain CT operated ammeter of 0-60 amps and indicating lamps with MCBs for `ON'/OFF`TRIP' status of pump motors. e. 1 No. auto start panel activated with pressure switch for diesel engine complete with all accessories, batteries, battery charger of suitable rating, MCB timers, push buttons, microprocessor based alarm annunciator, wiring and cabling including connection to diesel engine complete as required ready for working. f. outgoing feeder for 10 h.p. overhead booster pumps,including necessary automanual operation through prssure switches include cable lentgh from plant room to overhead booster pupms. g. Necessary cable alleys space for spare switches, internal wiring and copper earthing of all equipment . Note: All switch gears/control gears shall be motor duty rating.All MCCB's are suitable for motor duty and shall be of 25 KA breaking capacity.

1

-

28160

... More
Annual Maintenance by Refilling for 2 Kg co2 Gas cylinder for Fire Extignisher

20

-

13200

... More
Annual Maintenance by Refilling for 9Ltrs Foam type Fire Extignisher

20

-

28160

... More
Annual Maintenance by Refilling for 4.5 Kg co2 Gas cylinder trolly mounted for Fire Extignisher

20

-

31680

... More
Annual Maintenance by Refilling for 9kg mano amonium phospate powder type for fire estinguisher

20

-

61600

... More
Annual Maintenance of Intelligent and Anolog addressable photoelectric smoke detector with microprocessor in head and including mounting base with LED etc.

50

-

59400

... More
Annual Maintenance of Intelligent and electronically addressable, rate of rise cum fixed temperature thermistor type heat detector with mounting base, LED, fixed temperature setting.

1

-

2860

... More
Annual maintenance of manual call point with inbuilt turbo Isolator ,addressing done by the FACP as per BS 5839 AND duly approved by EN54/LPCB/VDS/FM

5

-

9900

... More
Annual Maintenance of Directional sounder with multitones for easy understanding and exit. The sounder shall be as per NFPA 72 recommendation.

7

-

16940

... More
Annual Maintenance of Intelligent and Anolog addressable beam detector of FDL 241-9 Lenear detector base DLR1191 reflector for Long Distance duly confirming to BS5839 Standards and duly approved by EN54

4

-

8272

... More
Annual Maintenance of Fire Detaction Control Panel Microprocessor based intelligent and electronically addressable, modular, expandable networkable, 10 loops (Expendable) (each loop consist of preferably a maximum of 150 detectors & devices fully loaded) fire alarm control panel with minimum 640 character LCD Display, with programming software and hardware lock, as per the specifications.

1

-

10560

... More
Annual maintenance by ensuring Power supply, temperature, noise levels, vibrations & other essential parameters are maintained at normal levels by taking preventive measures as per the manufacturer's standards so that the equipment is functioning smoothly .

1

-

3102

... More
Annual maintenance of voice alarm systems with recorded / live message / background music playing console, 12 speakers

1

-

10560

... More
IV) TRANSFORMERS AND HT AND LT PANEL: Annual Maintenance of Distribution Transformer 1000Kva-2 nos :-Annual maintenance by ensuring Power supply-voltage & current, frequency, equipment temperature, noise level, current Flow, terminations, vibrations, auto-voltage regulation, efficiency & other essential parameters are at maintained normal levels by taking preventive measures as per the manufacturer's standards so that the equipment is functioning smoothly in good working condition. The Distribution transformer is of following specification.The work should be carriedout as per the directions of the Engineer in Charge of the work. DistributionTransformer 2x1000Kva MAKE; Kirloskar. Type:- 3 PHASE, 50Hz, COPPER DOUBLE WOUND,OIL IMMERSED NATURALLY COOLED, CORE TYPE TRANSFORMER CONFORMING TO IS: 2026,CONTAINED IN MILD STEEL RADIATOR COOLED TANK WITH FIRST FILL OF OIL AS PER IS: 335 Output: 1000KVA,...No Load Voltage Ratio at rated Voltage & Frequency: 11Kv/0.433,...Cooling:ONAN,.. Type of Tap Change - OLTC WITH RTCC/AVR:-On load tap changer / RTCC.

2

-

167200

... More
Annual maintenance by ensuring Power supply-voltage & current, frequency, equipment temperature, noise level, current Flow, terminations, viberations & other essential parameters are at maintained normal levels by taking preventive measures as per the manufacturer's standards so that the equipment is functioning smoothly in good working condition.The work should be carriedout as per the directions of the Engineer in Charge of the work. 14SWG sheet steel clad fabricated, powder coat painted, totally enclosed free standing cubicle type HT panel board suitable for operation on 11KV 3Ph 50Hz AC earthed system, panel shall contain the equipment components as described below, complete with bus bar inter connections control wiring designation labels, caution notices, sealing and pad locking facilities wherever necessary space provision for entry of HT cables from the bottom through detachable gland plates having 1Nos VCB and 2Nos LBS 800A, 11KV horizontal draw out type Vacuum Circuit Breaker fitted with spring charged closing mechanism, mechanical ON/OFF indicator earth fault indication through core balance CT, 350 MVA capacity, with OL & EF relays and metering and indication lamps (voltmeter & meter)  -2 nos, 800A 11KV LBS, with 200A fuse and metering and indication lamps (voltmeter & Ammeter)   – 1 Nos.

2

-

96800

... More
Annual Maintenance by Servicing, Overhauling & Maintaining in good working condition 11kV Metering cubicle as per BESCOM norms along with and connected accessories, hardwares etc suitable for outdoor type complete as per latest IS standard technical specification.The work should be carriedout as per the directions of the Engineer in Charge of the work

1

-

13200

... More
Annual Maintenance by Servicing, Overhauling & Maintaining in good working condition Lightening Protector -Dynasphere MK 4-SS.Model-D/S MK4-SS completeThe work should be carriedout as per the directions of the Engineer in Charge of the work

1

-

6336

... More
Annual Maintenance of Charges for servicing of Air circuit breakers of following cleaning of ACB arcing contacts, main contactors / arc cuts testing of manual spring change motor, assembly testing of tripping coils and lubrication of ACB as per requirement of following capacity at main LT panel, Periodically maintenance for every six months. a) 2000 amps 4 pole electrically operated draw out ACB

10

-

17420

... More
b) 1250 amps 4 pole electrically operated draw out ACB

2

-

3168

... More
c) 800 amps 4 pole electrically operated draw out ACB

4

-

4752

... More
Annual Maintenance by Servicing of MCCB with control contacts operating mechanism and termination etc., main panel periodically maintenance for every six months of following capacity. a) 630 amps 3 pole MCCB as per manufacturer standard.

7

-

4312

... More
b) 400 amps 3 pole MCCB as per manufacturer standard.

3

-

1584

... More
c) 250 amps 3 pole MCCB as per manufacturer standard.

5

-

2200

... More
d) 125 amps 3 pole MCCB as per manufacturer standard.

13

-

5720

... More
e) 100 amps 3 pole MCCB as per manufacturer standard.

2

-

704

... More
f) 63 amps 3 pole MCCB as per manufacturer standard.

47

-

12408

... More
g)40 amps 3 pole MCCB as per manufacturer standard.

1

-

220

... More
h)25 amps 3 pole MCCB as per manufacturer standard.

4

-

880

... More
Annual Maintenance by Servicing of MCCB with control contacts operating mechanism and termination etc., main panel periodically maintenance for every six months of following of capacity. a) 400A Change Over Switch

2

-

1056

... More
b) 400 amps 3 pole MCCB as per manufacturer standard.

2

-

1056

... More
C) 63Amps 3pole MCCB as per manufacturer Standards

12

-

2640

... More
Annual Maintenance of Charges for servicing of auxiliary contactor, relay, timer testing of connections of all contactor relay timers and general checkup of control circuit of main change over panel. Periodically maintenance for every six months.

8

-

17600

... More
Annual Maintenance of Synchronisation Panel of 2 No.s 500 KVA DG setl: Annual maintenance by ensuring Power supply-voltage & current, frequency, equipment temperature, noise level, current Flow, terminations, viberations & other essential parameters are maintained at normal levels by taking preventive measures as per the manufacturer's standards so that the equipment is functioning smoothly in good working condition. The sequence of operations to be set as per requirement. The technical details are as stated below which needs to be maintained in good working condition. cubical type AMF Panel board made of sheet steel clad cubical pattern, free floor, standing, dust and vermin proof, totally enclosed compartmentalized formation design, panel shall conform to the IS 8623 specification.The enclosure have been fabricated out of cold-rolled sheet steel having a minimum thickness of 2 mm. The folded sections. Hinged typed doorshave been provided for feeder compartments. Doors for the bus bar chamber and cable alleyhave been plated screws onlyhave been used. 16G MS partitions / barriers have been provided between adjacent top and bottom compartments. Live parts have been properly shrouded. All the equipments mounted inside the panel have been accessible from the front. The maximum operating height of the switches should not be more than 1825 mm and minimum 350mm. Arrangement and rating of the bus bar main connections and wiring have been in accordance with IS:375/1963. Detachable type glanding plate have been provided for the cable alley at the bottom / top of the panel board for terminating the cables. All the doors provided with flat type rubber gaskets to prevent entry of dust, water, insects, worms etc., There have been engraved identification label fixed on the door of each modules/bus bar chambers, cable alleys, push button indicating lamps, contactor and relays, timers, fuses etc. complete. The bus bars have been suitable for 3 phase 4 wire 433 Volts 50Hz system. The bus bars have been made of high conductivity aluminium, strips conforming to IS specifications. The bus bars is having uniform cross sections throughout. The bus bars is capable for carrying the rated current at 433 Volts continuously. The Aluminum bus bar have been c`onsidered with current density of 0.8 Amps per Sq.mm. The bus bars have been designed to with stand a temperature rise of 45 degree C above the ambient temperature. The bus bars have been supported on suitable bus bar insulator at sufficiently close intervals and rigidly fixed so that they shall not undergo any distortion or damage under the thermal and dynamic stresses due to the system short circuits. All the bus bars have been insulated with heat shrinkable PVC sleeves and colour coded. All the control wiring have been used minimum size of 2.5sqmm. Flexible copper cable only. All the control system have been used fully electrically operated contactors and timer only. All control contacts have been provided with spring return contact. All replaceable contacts, coils, springs, control elements can be conveniently removed from the front panel without major dis-assembly / disconnection of power conductor. Sensing and control grade type with a minimum contact rating of 10 ampers. OPERATIONS: (a) The normal or main source have been constantly monitored by a main voltage monitor. (b) When mains voltage varies below 80% and above 120% of the rated voltage the automatic control system shall give a starting signal to the diesel generator set. (c) In the event of the failure of the diesel generator set due to faulty starting, the normal source can be energised without any time delay on the restoration of the normal source. (d) If the DG set fails to start and reach its operating speed in 20/25 secs. In three or four attempts, the set shall automatically be disconnected and locked in isolated position. (e) A test switch to simulate a normal source failure have been provided for routine testing of the transfer switch panel and DG set. (f) Engine starter should not attempt while engine is in running condition to prevent mal function. Incomer; 1 Nos. of of required Amps 4 pole 65 KA Ics. EDO ACB ( foreach of 1010 KVA DG Sets) The ACB have been fitted with micro processor based tripping released and has been over load, instantaneous short circuit and earth fault protections. Further the over loadhave been settable from 40 to 100% of In with trip time adjustment of 3-4seconds , instantaneous short circuit sttable from 1.5 to 15 times In ; selective short circuit protections adjustable from 0.60 to 10 times In trip time adjustable from 0.05 seconds to 0.75 seconds; Earth fault protections settable from 10-40% In . The tripping release has been liquid crystal desplay for displaying current and has been trip indications for all protection functions. The ACB has been an insulation voltage of 1000V, service voltage of 690 V , Impulse withstand voltage of 12 KV and shall conform to IEC 947-2 . The ACB have been with following accessaries . (i) closing coil,... (ii) Shunt trip release,.. (iii) U.V. Release,. 2nos .

1

-

117560

... More
Annual maintenance of Earth pit by replacing rusted nut and bolts ,painting and naming

40

-

52800

... More
V) AUDIO VIDEO SYSTEM : Annual maintenance by ensuring Power supply-voltage & current, equipment temperature, noise level, Data Flow, terminations, viberations, & other essential parameters are maintained at normal levels by taking preventive measures as per the manufacturer's standards so that the equipment is functioning smoothly and connfigured to run necesscary applications- comprisiing of below said items & quantities. The work should be carriedout as per the directions of the Engineer in Charge of the work. 2-way, full-range array module loudspeaker shall contain six (6) 2-inch titanium-diaphragm compression drivers mounted to a continuous-arc diffraction-slot manifold. The manifold will provide acoustic summation that is free from significant peaks or dips in response, from 500 Hz to 16 kHz, and exit into a constant-directivity waveguide with effective pattern control to approximately 1 kHz. The low-frequency section shall contain two (2) 10-inch cone transducers with 3-inch voice coils, with each woofer contained in a separate vented enclosure. The array module loudspeaker shall meet the following performance specifications: On-axis system frequency response shall be 60 Hz to 16 kHz (+/- 3 dB) with recommended crossover and active equalization. The low-frequency sensitivity shall be 93 dB SPL in free field with 1 W input and be capable of producing peak output of 126 dB SPL on axis at 1 meter, with recommended equalization. The high-frequency sensitivity shall be 104 dB SPL in free field with 1 W input and be capable of producing peak output of 132 dB SPL on axis at 1 meter, with recommended equalization. The low-frequency section shall have a long-term power handling rating of 500 W and a nominal input impedance of 4 ohms. The high-frequency section shall have a long-term power handling rating of 150 W and a nominal input impedance of 8 ohms. Power handling will be rated using IEC 268-5 pink noise, 6-dB crest factor, for 100 hours, with recommended EQ. The nominal coverage pattern shall be 120 horizontal and 10 vertical. The woofer and waveguide sections will be protected by separate 19-gauge (1.0 mm) perforated steel grilles with powder-coated finish. Input connectors shall be two (2) parallel-wired NeutrikNL4 Speakon connectors with necessary Mounting Accessories. Bose RM 12010 Loud Speakers

2

-

70400

... More
Annual Maintenance of 2-way, full-range array module loudspeaker shall contain six (6) 2-inch titanium-diaphragm compression drivers mounted to a continuous-arc diffraction-slot manifold. The manifold will provide acoustic summation that is free from significant peaks or dips in response, from 500 Hz to 16 kHz, and exit into a constant-directivity waveguide with effective pattern control to approximately 1 kHz. The low-frequency section shall contain two (2) 10-inch cone transducers with 3-inch voice coils, with each woofer contained in a separate vented enclosure. The array module loudspeaker shall meet the following performance specifications: On-axis system frequency response shall be 60 Hz to 16 kHz (+/- 3 dB) with recommended crossover and active equalization. The low-frequency sensitivity shall be 93 dB SPL in free field with 1 W input and be capable of producing peak output of 126 dB SPL on axis at 1 meter, with recommended equalization. The high-frequency sensitivity shall be 101 dB SPL in free field with 1 W input and be capable of producing peak output of 129 dB SPL on axis at 1 meter, with recommended equalization. The low-frequency section shall have a long-term power handling rating of 500 W and a nominal input impedance of 4 ohms. The high-frequency section shall have a long-term power handling rating of 150 W and a nominal input impedance of 8 ohms. Power handling will be rated using IEC 268-5 pink noise, 6-dB crest factor, for 100 hours, with recommended EQ. The nominal coverage pattern shall be 120 horizontal and 20 vertical. The array module loudspeaker shall be constructed of 11-ply Baltic birch plywood, protected by a polyurethane coating, for top and bottom waveguide sections, engineered-plastic composites for the woofer enclosures, and steel spar beams connecting the integral side-plate steel rigging hardware. The rigging hardware shall support up to 8 similar array module loudspeakers with a 10:1 Safety Factor. The woofer and waveguide sections will be protected by separate 19-gauge (1.0 mm) perforated steel grilles with powder-coated finish. Input connectors shall be two (2) parallel-wired Neutrik NL4 Speakon connectors with necessary Mounting Accessories. Bose RM 12020 Loud

2

-

63360

... More
Annual Maintenance of 2-way, full-range array module loudspeaker shall contain six (6) 2-inch titanium-diaphragm compression drivers mounted to a continuous-arc diffraction-slot manifold. The manifold will provide acoustic summation that is free from significant peaks or dips in response, from 500 Hz to 16 kHz, and exit into a constant-directivity waveguide with effective pattern control to approximately 1 kHz. The low-frequency section shall contain two (2) 10-inch cone transducers with 3-inch voice coils, with each woofer containe in a separate vented enclosure. The array module loudspeaker shall meet the following performance specifications: On-axis system frequency response shall be 60 Hz to 16 kHz (+/- 3 dB) with recommended crossover and active equalization. The low-frequency sensitivity shall be 93 dB SPL in free field with 1 W input and be capable of producing peak output of 126 dB SPL on axis at 1 meter, with recommended equalization. The high-frequency sensitivity shall be 98 dB SPL in free field with 1 W input and be capable of producing peak output of 126 dB SPL on axis at 1 meter, with recommended equalization. The low-frequency section shall have a long-term power handling rating of 500 W and a nominal input impedance of 4 ohms. The high-frequency section shall have a long-term power handling rating of 150 W and a nominal input impedance of 8 ohms. Power handling will be rated using IEC 268-5 pink noise, 6-dB crest factor, for 100 hours, with recommended EQ. The nominal coverage pattern shall be 120 horizontal and 60 vertical. The array module loudspeaker shall be constructed of 11-ply Baltic birch plywood, protected by a polyurethane coating, for top and bottom waveguide sections, engineered-plastic composites for the woofer enclosures, and steel spar beams connecting the integral side-plate steel rigging hardware. The rigging hardware shall support up to 8 similar array module loudspeakers with a 10:1 Safety Factor. The woofer and waveguide sections will be protected by separate 19-gauge (1.0 mm) perforated steel grilles with powder-coated finish. Input connectors shall be two (2) parallel-wired Neutrik NL4 Speakon connectors with necessary Mounting Accessories. Bose RM 12060 Loud Speakers / Meyer Sound / L acoustic or Equivalent

2

-

61600

... More
Annual Maintenance of subwoofer array module loudspeaker shall contain two (2) 15-inch high-excursion cone transducers with 4-inch voice coils. The low frequency drivers shall be loaded into a direct-radiating vented enclosure. The array module subwoofer shall meet the following performance specifications: On-axis system frequency response shall be 40 Hz to 280 Hz (- 10 dB). The module sensitivity shall be 97 dB SPL in free field and 103 dB SPL in half-space loading with 1 W input. Maximum continuous output shall be 127 dB SPL in free field and 133 dB SPL in half space loading. Maximum peak output shall be 133 dB SPL in free field and 139 dB SPL in half space loading. Each 15-inch transducer shall have a long-term power handling rating of 500 W (using IEC 268-5 pink noise, 6-dB crest factor, for 100 hours, with recommended EQ) and a nominal input impedance of 8 ohms. The subwoofer module loudspeaker enclosure shall be constructed of 13-ply Baltic birch plywood, protected by a twopart polyurethane coating. The transducers shall be protected by an 18-gauge (1.2 mm) perforated steel grille with powdercoated finish. Input connectors shall be two (2) parallel-wired Neutrik NL4 Speakon connectors, which shall be wired to provide discrete amplifier channel drive to each transducer. Bose RMS 215

4

-

96800

... More
Annual maintenance of loudspeaker shall be a multiple driver, full-range system with matched active equalization as follows: The transducer complement shall consist of four (4) full-range environmental drivers of 4.5" (114 mm) diameter, mounted vertically in a faceted baffle. Each driver shall have a rated impedance of 1.6 ohms and shall be wired in series, resulting in a composite speaker assembly nominal impedance of 8 ohms. The system sensitivity shall be 99 dB SPL in the 300 Hz to 3 kHz range and 89 dB SPL in the 90 Hz to 17 kHz range with both measurements referenced to a 1 watt (2.83 V) pink noise input at 1 meter. The nominal horizontal beamwidth shall be 120 degrees, and the nominal vertical beamwidth shall be 60 degrees. The power handling capacity of the loudspeaker shall be 120 watts continuous pink noise, band-limited from 90 Hz to 17 kHz. The loudspeaker shall be provided with a ducted vent system, tuned at 95 Hz. The input connectors of the 402 Series II loudspeaker shall consist of two (2) parallel-wired NL4 Neutrik Speakon connectors. The enclosure of the 402 Series II loudspeaker shall be composed of mica-reinforced structural foam. Its outer dimensions shall be 23.3" x 8.2" x 8.0" (592 mm x 208 mm x 202 mm); its weight shall be 15 lb (7.0 kg). The loudspeaker shall be the Bose Panaray402 Series II loudspeaker with wall mount brackets to install the speakers on the wall. Bose 402 Loud Speakers

4

-

21120

... More
Annual maintenance of loudspeaker shall be a multiple driver, full-range system with matched active equalization as follows: The transducer complement shall consist of four (4) full-range environmental drivers of 4.5" (114 mm) diameter, mounted vertically in a faceted baffle. Each driver shall have a rated impedance of 1.6 ohms and shall be wired in series, resulting in a composite speaker assembly nominal impedance of 8 ohms. The system sensitivity shall be 99 dB SPL in the 300 Hz to 3 kHz range and 89 dB SPL in the 90 Hz to 17 kHz range with both measurements referenced to a 1 watt (2.83 V) pink noise input at 1 meter. The nominal horizontal beamwidth shall be 120 degrees, and the nominal vertical beamwidth shall be 60 degrees. The power handling capacity of the loudspeaker shall be 120 watts continuous pink noise, band-limited from 90 Hz to 17 kHz. The loudspeaker shall be provided with a ducted vent system, tuned at 95 Hz. The input connectors of the 402 Series II loudspeaker shall consist of two (2) parallel-wired NL4 Neutrik Speakon connectors. The enclosure of the 402 Series II loudspeaker shall be composed of mica-reinforced structural foam. Its outer dimensions shall be 23.3" x 8.2" x 8.0" (592 mm x 208 mm x 202 mm); its weight shall be 15 lb (7.0 kg). The loudspeaker shall be the Bose Panaray402 Series II loudspeaker with wall mount brackets to install the speakers on the wall. Bose 402 Loud Speakers

2

-

22000

... More
Annual maintenance of loudspeaker shall be a multiple-driver, full-range loudspeaker., the transducer complement shall consist of two (2) low-frequency drivers of 5.25" (133 mm) diameter, mounted symmetrically in pairs, with six (6) 2.25" (57 mm) drivers in an Articulated Array® loudspeaker design. The loudspeaker shall have a cabinet shape to enable the floor array to be used in three different floor positions. The loudspeaker shall have a rated nominal impedance of 8 ohms. The loudspeaker system sensitivity shall be 90 dB SPL in the 70 Hz – 16 kHz frequency range, with measurements referenced to 1 watt (2.85 V) pink noise input at 1 meter The dispersion shall be 40° H by 120° V in the individual position, 120° H by 40° V in the group-near position and 120° H by 40° V in the group-far position. The power-handling capacity of the loudspeaker shall be 200 watts IEC band-limited, from 70 Hz – 16 kHz. The input connectors of the loudspeaker shall consist of two (2) parallel-wired NL4 Neutrik® Speakon® connectors wirh necessary Mounting Accessories. Bose 620M Monitor Loud Speakers

4

-

13732

... More
Annual Maintenance of Gooseneck microphone for speech reinforcement.The unit shall be streamlined in appearance, with a boom diameter of 8 mm (.31”) and an overall length of 15 cm (5.9”) and 40 cm (15.75”). It must also be finished with a durable anti-reflective matte black coating and have a pre-amp housed with its XLR-5 connector housing. The unit must be mountable using a table stand, direct to surface receptacle or via a silent shock mount system. with Base The unit shall accept the ME34, ME35 and ME36 microphone capsules.vibration noise. Sennheiser MEG 14-40b with MZTX 31PTT Gooseneck Mic with base Beyerdynamic

6

-

13200

... More
Annual maintenance of a wireless microphone system shall feature a true-diversity receiver with 42 MHz of available tuning bandwidth with a total of 1,680 frequencies accessible in 25 kHz steps. The wireless microphone receiver must feature one Balanced XLR output with a max. output of +18 dBu, and one unbalanced ¼” output with a max. output of +12 dBu. The wireless microphone receiver must feature two BNC antenna inputs, one for each receiver module in the true diversity system. The wireless microphone receiver must feature a backlit display that displays AF and RF levels, battery telemetry from the transmitter, operating frequency, and diversity switching information. The wireless microphone receiver must feature an automatic frequency scanning function that utilizes twenty (20) banks of pre-coordinated frequencies that are free of intermodulation interference. The wireless microphone receiver must also feature a user bank in order to store user defined frequencies. The wireless microphone transmitter must operate on two 1.5V AA battery cells. The wireless microphone transmitter must have access to 1,680 frequencies tuned in 25 kHz steps across a defined 42 MHz bandwidth. The wireless microphone transmitter must feature a backlit display that displays frequency information, AF level, battery level. The wireless microphone transmitter must transmit a pilot-tone squelch. The wire¬less microphone transmitter must have a specified RF output power of 30mW. The wireless microphone receiver must accept 12V DC power via BNC antenna inputs. Beyerdynamic

4

-

14080

... More
Annual Maintenance of lavalier wireless microphone system shall feature a true-diversity receiver with 42 MHz of available tuning bandwidth with a total of 1,680 frequencies accessible in 25 kHz steps. The wireless microphone receiver must feature one balanced XLR output with a max. output of +18 dBu, and one unbalanced ¼” output with a max. output of +12 dBu. The wireless microphone receiver must feature two BNC antenna inputs, one for each receiver module in the true diversity system. The wireless microphone receiver must feature a backlit display that displays AF and RF levels, battery telemetry from the transmitter, operating frequency, and diversity switching information. The wireless microphone receiver must feature an automatic frequency scanning function that utilizes twenty (20) banks of pre-coordinated frequencies that are free of intermodulation interference. The wireless microphone receiver must also feature a user bank in order to store user defined frequencies. The wireless microphone transmitter must operate on two 1.5V AA battery cells. The wireless microphone transmitter must have access to 1,680 frequencies tuned in 25 kHz steps across a defined 42 MHz bandwidth. The wireless microphone transmitter must feature a backlit display that displays frequency information, AF level, battery level. The wireless microphone transmitter must transmit a pilot-tone squelch. The wireless microphone transmitter must have a specified RF output power of 30mW. The wireless microphone receiver must accept 12V DC power via BNC antenna inputs. Beyerdynamic

3

-

10032

... More
Annual Maintenance of sturdy metal housing ,Automatic frequency management for transmitter and receiver, Tunable UHF frequencies within a large switching bandwidth, Programmable MUTE switch, Headset microphone with optimized acoustics, Wireless synchronization of transmitters via infrared interface, Enhanced frequency bank management with up to 12 compatible frequencies per bank, 42 MHz bandwidth 1680 switchable frequencies, Increased range for audio sensitivity, Easy-to-read illuminated dot matrix display, 4-level charge indicator for transmitter battery, More control options (menu), Enhanced AF frequency range, Soundcheck mode, Integrated equalizer, Contacts for recharging the BA 2015 accupack directly in the transmitter, 2 AA batteries for more than 8 hours of use, HDX compander for crystal-clear sound, True diversity receiver for optimum reception, High RF output power for large range, Suitable for 19" rack mounting (1 U). Sennheiser EW 152 G3, Headworne / Beyerdynamic / Shure or equivalent

3

-

9900

... More
Annual Maintenance of Drum Kit should be a reliable and cost-effective drum microphone package for recording and live sound reinforcement alike. The package should includedynamic kick drum microphone, four tom/snare microphones, and a pair of supercardioid overhead microphones. The microphones and their associated hardware are all shipped in a slim-line aluminum case with die-cut foam. Sennheiser Drum Kit 600 / Beyerdynamic

1

-

3735

... More
Annual Maintenance of exceptionally lively, clear sound, Quick and flexible set-up; comes with suitable mounting clamp, Optimal positioning with long-necked, flexible boom, Integrated shock absorber eliminates handling noise, Intelligent MZA 900 P in-line-preamp, (cable, phantom power & level check) ,Each e 908 variant can optionally be used with any Evolution Wireless bodypack transmitter, in-line-pramp, Pouch, Instructions for use. Sennheiser e 908 B for Saxophone / Beyerdynamic / Shure or equivalent

4

-

14940

... More
Annual Maintenance of DI Boxes. Behringer DI 1000 Boxes/ Yamaha or equivalent

4

-

7144

... More
Annual Maintenance of sound processor shall be a DSP-based signal processor. The processor shall include eight general-purpose control outputs and eight general-purpose inputs with expansion capabilities for up to a total of 16 general-purpose control outputs and 16 general-purpose inputs. The processor shall include Ethernet, RS-232 and RS-485 ports. Certifications shall include cUL, C-Tick and IEC60065, and have a CB report including all ountry deviations. Processor and peripherals shall meet EN55103-1 and EN55103-2 EMC requirements. The system shall include PC-based design and control and configuration software, and communicate with the DSP and other parts of the system via Ethernet with full IP addressability and password protection. The processor and design software shall include the following minimum set of processing modules: Bose loudspeaker EQs, Bose crossovers, crossovers, graphic and parametric EQs, routers, delays, matrix mixers, automatic microphone mixer, signal generators, meters, compressor/limiters, duckers, automatic gain controls, gate, room combiner and source selectors. All signal-processing modules, parameter sets, presets and groups shall be directly controllable by third-party devices via the RS-232 port.

1

-

132000

... More
Annual Maintenance of Extended Dynamic range input Card for the above said Processor. Bose ESP EDR input Crad.

1

-

4224

... More
Annual Maintenance of Extended Dynamic range Output Card for the above said Processor. Bose ESP EDR Output Crad/ Meyer sound / L acoustic or equivalent

2

-

8448

... More
Annual Maintenance of amplifier shall contain all solid-state circuitry, using MOSFET output devices employing Class-D topology with both current and voltage feedback loop circuits. The amplifier shall incorporate a switch-mode power supply with fast-tracking, power-factor correction circuits that will allow full-rated power from AC outlets ranging from 100 – 240 V, 50/60 Hz. The amplifier shall have an IEC 320-C19 16/20-amp electrical power inlet and shall be equipped with a removable power supply cord. The amplifier shall include protection from shorted and open loads, general verheating, DC, high-frequency overloads, under/over voltage and internal faults. The amplifier shall contain eight independent amplifier channels, which can be configured to allocate the 4000 watts total rated output power between 2 and 8 channels. The amplifier shall contain variable speed fans, which are controlled by software to minimize acoustic noise. Fan airflow will be from the front panel to the rear panel. Rack mounting of multiple amplifiers shall be possible without extra rack spacing for ventilation. The amplifier shall be capable of continuous operation at 1/3 of rated power into 4-ohm loads, in ambient temperatures up to 104° F (40° C).

5

-

98705

... More
Annual Maintenance of 2-line x 40-character backlit LCD ,Four encoders for changing the gain or selecting scenes/sources, Each encoder includes a 15-segment LED array for indicating the current level or state ,Each encoder features push buttons for muting gain controls or making selections, Sixteen gain/selector controls (four banks of four), Ten-character descriptions of the gain control or scene appear on the LCD above the encoder, Lock function in software prevents local changes, 10Base-T Ethernet network communication Up to 16 CC-64 control centers can be connected per system Power over Ethernet cable or separate cable LEDs for status, link and network transmit/receive Fits standard 5-gang wall box UL 6500 listed and CE approved Bezel is removable for podium or rack-panel mount. Bose CC 64 / Meyer Sound / L Acoustic or Equivalent

1

-

5280

... More
Annual Maintenance of 2 channel graphic equalizer shall be used to equalize the floor monitors. It shall offer complete independent control from the input all the way to the output. The equalizer shall offer a 31 band control over the entire 20hz to 20KHz range for precise equalization. The equalizer shall offer a high pass filter that allows setting the roll of frequency using a slider. The high pass filter should meet the 12dB/octave. The THD should be less than 0.05%(THD+N),20Hz to 20KHz@+4dB,600 ohm. Behringer FBQ 3102 Graphic Equalizer

2

-

4928

... More
Annual Maintenance of 32 channel analogue mixer. Yamaha MG32/FX

1

-

30360

... More
Annual Maintenance of Blu Ray Player with USB to play the music material without any distortion. Sony BDP-S380 / Phillips

1

-

2200

... More
VI) GENERAL LIGHTING SYSTEM: Annual maintenance by ensuring Power supply-voltage & current, equipment temperature, & other essential parameters are maintained at normal levels by taking preventive measures as per the manufacturer's standards so that the equipment is functioning smoothly and connfigured to run necesscary applications- comprisiing of below said items & quantities. The work should be carriedout as per the directions of the Engineer in Charge of the work. Digital HFR Ballast dimming of 64 zone dimming controller, 1-10VDC, inclusive of Power supply module, Surge Arrester, Bus Connection Terminal, IP interface, Switch / Dimmer Actuators, Gateway

1

-

33484

... More
Annual Maintenance of reccessed / surface mount aesthetic 2'X2' modular 18 watts LED fittings replacing LED bulbs and soldering in case loose connection in the wirring by using scaffolding or ladder in area of convention center

42

-

25116

... More
Annual Maintenance of reccessed / surface mount aesthetic 2'X2' modular Dimmable/regular by replacing Choke/36 watts CFL by using scaffolding or ladder in area of convention center

444

-

206904

... More
Annual Maintenance of reccessed / surface mount aesthetic 3x36 watts mirror optic' modular luminary by replacing Choke and 36 watts fluroscent tube by using scaffolding or ladder in area of convention center

12

-

4116

... More
Annual Maintenance of reccessed / surface mount aesthetic round/rectangular/down type modular 18 watts FL fittings replacing CLF and choke by using scaffolding or ladder in area of convention center

711

-

174906

... More
Annual Maintenance of surface mount round round shaped 9 watts staire case LED lighting fixtures by replacing LED bulbs and soldering in case loose connection in the wirring using scaffolding or ladder in area of convention center

17

-

6273

... More
Annual Maintenance of Exit sign lights with 5 W LED lamps replacing spare parts like adopter LED bulb etc

10

-

8360

... More
Annual Maintenance of Cow lights replacing LEDstrip and soldering in case loose connection in the wirring using scaffolding or ladder in area of convention center

168

-

14784

... More
Annual Maintenance of all capacities fluorescent /spotlight/ CFL indoor fittings on the wall / ceiling using 23/0.0076" twin twisted RVC insulated wires, required nos of round blocks and clamps (if required) On wall/ceiling/ falseceiling

658

-

13818

... More
VII) STAGE LIGHTING: Annual maintenance of Motorized Operated System The system shall be for horizontally operative in two sections the main machine system shall consist of 230 Volts-AC 50Hz, 1 H P single phase forward / reverse rotation D. C motor, coupled to a worm Gear box, the electrical circuit for operation shall consist of 2 Nos. multiple contact air circuit breakers of approved make, wiring of remote controlled forward / stop/ reverse operation remote controlled by 3 push button set of, remote control station. Size: 26 Rmt Main Curtain, Centre Curtain & Backdrop Curtain

3

-

35640

... More
Annual maintenance of. STAGE LIGHTING EQUIPMENT, Electronic Dimmer lighting Control desktop lighting control console and control cable to dimmer rack. Lighting Control Console to have parallel connection to have the following features. 24 channel control panel (48 in wide mode) consisting of 12 sub masters in 9 pages manual control with 2 sub masters, 1 master fader, blinker switches, effects control, DMX output and soft patch to 512DMX channels, 400 memories, LCD menus, Floppy disk drive, HTP control etc.

1

-

23760

... More
Annual maintenance of rack mounted electronic dimmer comprising 24 dimmer packs. Dimmer packs to have following features. Rack Mountable (standard 19” EIA equipment rack) Single channel unit, 3 units per rack space Power rating 4000 Watts each continuous. Fan Cooled. Single Phase, 240 V AC, 50Hz.Control Input: 0-10VDC. Electronic indefinite short circuit and overload protection. Front panel DP (SPN) MCBs for power incoming. Outgoing circuit fuse protected. Power connections with adequately size terminal blocks. Control connections Via XLR or DINRFI protection with chokes in each circuit. Surge protection with snubbers. Suitable for continuous operation at ambient temperature of 45 deg C.Complete with floor stand rack with DMX Control Panel. Make – Modern stage Model XL20 x24

1

-

33440

... More
Annual maintenance of Par light lamp 1000 W par Q/MFL- Sealed beam, Parabolic aluminum Housing CRC sheet metal matt black with ventilation Including replacement of lamp Make – Modern Stage Type Par-64.

36

-

38016

... More
Annual maintenance of P C Spot Light of Plano Convex Spot Light with 150mm dia. Plano Convex lens, 1000w halogen lamp, 240 V CRC sheet metal body with matt black powder coat finish Complete with barn- doors, gel holder Including replacement of lamp Make- modern Stage Type SL35H

8

-

9856

... More
Annual maintenance Profile Spot Light with 2nos 150mm Plano convex lens1000w bipin halogen lamp, 240 V Aluminum anodized spherical reflectors CRC sheet metal body with black paint Complete with lamp, GI hook clamp suitable for 50mm dia bar, Gel holder Including replacement of lamp Make - Modern stage Type 220

8

-

11472

... More
Annual maintenance of Fresnel Spot Light with 150mm dia. Fresnel lens, 1000w halogen lamp, 240 V CRC sheet metal body with matt black powder coat finish Complete with lamp, GI hook clamp suitable for50mm bar, With barn-doors, gel holder Including replacement of lamp Make - Modern Stage Type Sapphire 1000

8

-

12320

... More
Annual maintenance of Halogen Flood Light 1000w with mesh and born Door consisting 2 Nos Single contact suitable compressible holders, Yoke, 1000w halogen tube and clamp to the existing lighting bar Including replacement of lamp Make - Modern stage

6

-

2214

... More
Annual maintenance of LED Par Light PL-64/15, 160 pcs x high power 10mm LED, Equipped with 4 DMX Channels, Manual DMX address by dip switch, Full range dimming & variable strobe effect/1,00,000 hours working lamp lie, Linear dimming/strobe, Lightweight high polish aluminum case, Pre Programmed function, Stand alone mode with preprogrammed patterns. Smooth fade in/fadeout available,Case for ingenious colors performance Including replacement of lamp

24

-

73920

... More
Annual maintenance of Cyclorama Light Wide angle cyclorama floodlight 500w tubular halogen lamp, 240V Realized asymmetrical aluminum hammer finish reflector CRC sheet metal body with matt black powder coat finish Complete with lamp, GI hook clamp suitable for 50mm bar, Gel holder Including replacement of lamp Make –Modern Stage Type HF-500.

16

-

7456

... More
Annual maintenance of Fallow Spot light of SGM Newton 1200 with stand Follow Spot light Including replacement of lamp

1

-

22880

... More
Annual maintenance of Patch Panel rack mounted dimmers packs. Patch panel to have following features. Floor mounted patch panel with bottom cable entry, and hinged front panel. Patch points: Patch points: 96 way, incoming from dimmers, and 98 outgoing circuits to light points. Single pole patching with sliding, shrouded, electrical contact. Patch leads to be electrical safe in worst-case condition. Patch leads to be flexible, single conductor, stranded, min 2.5sq mm, VIR insulated. Each outgoing circuits protected with a 10A MCB with thermal and magnetic trips. Flexible patching to allow up to 4 Light on a single dimmer. Neutral and earthling buses to be aluminum bar of not less than 150sq mm. All incoming and outgoing connection via 10 A barriers terminal strips. All cable entries to be properly glanded.

1

-

17600

... More
Annual maintenance of Light Bar of Motorized dual barrel 4 rope lighting bar complete with cable laying tray’s necessary pulley, brackets lighting junction boxes, cable terminal box fitted to the lighting bar and, 1 cable terminating box at grid level to terminate the looped cables 1.5 HP D C Motor and fully oil/Grease Immersed reduction gear box extreme limit controllers and mounting frames.

3

-

44880

... More
IX) OUT DOOR LIGHTS: Annual maintenance of LED Bollard lights asper the manufacture standard by ensuring power supply with replacing spare parts if necessary

50

-

66000

... More
Annual maintenance of LED and MH buiding lights asper the manufacture standard by ensuring power supply with replacing spare parts if necessary

10

-

15400

... More
X) UPS SYSTEMS: Annual Maintenance of online UPS system by maintain repaire the said equipment to keep it under working condition for normal usage and routine Preventive maintenance carried out four times in year. a)Emerson make 2KVA with batteries complete unit

2

-

55756

... More
b)Emerson make 3KVA with batteries complete unit

2

-

55756

... More
c)APC make 30KVA with batteries complete unit

1

-

200036

... More
XI) FOUNTAIN: Annual maintenance of Inline Flower fountain consisting 1 No. of 7.5 HP kirloskar horiztonal submersible monoblock pumpset, suction and delivery fittings, Brass mesh straienr filter, 5 Nos. Of flower jets with approximate 30 Nos. of adjustable ball joint ball nozzles on non-corosive aluminium alloy nozzle body. 15 Nos. of 150 watt reflector under water nonsequencing multi colour fixed lights with imported colour filters in sandwich construction, 5 Nos. of pressure regualting valves, 5 Nos. of powder coated lighting bracket, Necessary 10 Kg. PVC piping and SS fittings, electrical control panel suitable for 7.5 HP pumpset and multicolour fixed lighting system, wiring transportation and installation. Water effect : 3-4 ft. regulatable.

1

-

21560

... More
XII. CONCURRENCE MEETING HALL AUDIO & VIDEO SYSTEM: Annual maintenance of 40W ceiling mount Loud speaker with variable tapping between 2.5 W to 40W, peak power max 160W,8 Ohm Impedance, 87 dB Sensitivity, 103dBSPL Peak frequency range between 70 Hz to 19 KHZ with a conical coverage pattern of 125 degree and the product shall be UL & NFPA Certified Refer Technical Specifcations A1

24

-

31680

... More
Annual maintenance of 16W ceiling mount Loud speaker with variable tapping between 2.W to 16W, peak power max 64W,8 Ohm Impedance, 84 dB Sensitivity, 102 dBSPL Peak frequency range between 90 Hz to 16 KHZ with a conical coverage pattern of 140 degree and the product shall be UL & NFPA Certified Refer Technical Specifications A2

30

-

31680

... More
Annual maintenance of 2 Channel Mixer Amplifier with 120W at 4Ohms each channel, 2*65W at 8 Ohms, Freq Response 40 Hz - 16 KHz 24 bit integrated DSP with front panel LED Display with 4 mic and line inputs with UL & CE Certifications Refer Technical Specifications A4

6

-

80082

... More
Annual Maintenance of Volume Controller The unit will have a remote input with a 6-pin Euroblock connector for using one or two volume controls and/or volume control with A/B select user interfaces. The unit shall be configurable via the onboard controls and feature a “lockout” feature to prevent unwanted system changes. An RS-232 COM port will be available for system updates. The unit shall be the Bose® FreeSpace® DXA 2120 digital mixer/amplifier Refer Technical Specifications A5

2

-

1724

... More
Annual maintenance of B141 Goseneck microphone shall be a pre-polarized condenser designed for permanent installation or portable applications. It shall have a KE 10 microphone capsule with a cardioid polar pattern with uniform 120° angle of acceptance (-3dB). It shall have a frequency response of 50 Hz to 20,000 Hz and be capable of handling sound input levels up to 130 dBspl. Nominal equivalent noise level shall be 26 dBA (37 dB weighted as per CCIR 468-3). Output shall be low impedance balanced (<100 ohms). Operating temperature shall be 32° – 104° F (0° – 40° C). The microphone shall operate from an external 12V to 48V DC phantom power source; current consumption shall be 3 mA. The microphone shall offer radio frequency interference (RFI) shielding against intermodulation from wireless equipment or devices, streamlined 40 cm gooseneck with a XLR 3M connector. the table stand for connecting and operating XLR gooseneck microphones shall be rugged and unobtrusive. It shall feature an XLR-3F microphone input and an XLR-3M microphone output. The table stand shall operate on 48 V phantom power. Current consumption shall be 1.9 mA. Dimensions shall be 120 x 170 x 43 mm Refer Technical Specifications A6.

2

-

4444

... More
Annual maintenance of wireless Hand heald microphone system shall feature a true-diversity receiver with 42 MHz of available tuning bandwidth with a total of 1,680 frequencies accessible in 25 kHz steps. The wireless microphone receiver must feature one balanced XLR output with a max. output of +18 dBu, and one unbalanced ¼” output with a max. output of +12 dBu. The wireless microphone receiver must feature two BNC antenna inputs, one for each receiver module in the true diversity system. The wireless microphone receiver must feature a backlit display that displays AF and RF levels, battery telemetry from the transmitter, operating frequency, and diversity switching information. The wireless microphone receiver must feature an automatic frequency scanning function that utilizes twenty (20) banks of pre-coordinated frequencies that are free of intermodulation interference. The wireless microphone receiver must also feature a user bank in order to store user defined frequencies. The wireless microphone transmitter must operate on two 1.5V AA battery cells. The wireless microphone transmitter must have access to 1,680 frequencies tuned in 25 kHz steps across a defined 42 MHz bandwidth. The wireless microphone transmitter must feature a backlit display that displays frequency information, AF level, battery level. The wireless microphone transmitter must transmit a pilot-tone squelch. The wireless microphone transmitter must have a specified RF output power of 30mW. The wireless microphone receiver must accept 12V DC power via BNC antenna inputs. Microphone : Omni directional ,Max db- 120dB SPL Refer Technical Specifications A7

10

-

17600

... More
Annual maintenance of CCTV System of honey wall make, Maintenace scope includes regular monitoring and sericing for following items of wireless Lapel microphone system shall feature a true-diversity receiver with 42 MHz of available tuning bandwidth with a total of 1,680 frequencies accessible in 25 kHz steps. The wireless microphone receiver must feature one Balanced XLR output with a max. output of +18 dBu, and one unbalanced ¼” output with a max. output of +12 dBu. The wireless microphone receiver must feature two BNC antenna inputs, one for each receiver module in the true diversity system. The wireless microphone receiver must feature a backlit display that displays AF and RF levels, battery telemetry from the transmitter, operating frequency, and diversity switching information. The wireless microphone receiver must feature an automatic frequency scanning function that utilizes twenty (20) banks of pre-coordinated frequencies that are free of intermodulation interference. The wireless microphone receiver must also feature a user bank in order to store user defined frequencies. The wireless microphone transmitter must operate on two 1.5V AA battery cells. The wireless microphone transmitter must have access to 1,680 frequencies tuned in 25 kHz steps across a defined 42 MHz bandwidth. The wireless microphone transmitter must feature a backlit display that displays frequency information, AF level, battery level. The wireless microphone transmitter must transmit a pilot-tone squelch. The wireless microphone transmitter must have a specified RF output power of 30mW. The wireless microphone receiver must accept 12V DC power via BNC antenna inputs. Refer Technical Specifications A8

2

-

9152

... More
Annual maintenance of Boundary Layer Microphone with Frequency response of 40Hz to 20K Hz and sensitivity will be 16mv/Pa, nominal impedance of 200 Ohms, dynamic range 104dB A, Max spl will 125dB, The microphone shall provide XLR-3 Connector with M20 Thread Refer Technical Specifications A9

16

-

35200

... More
Annual maintenance of Digital Signal Processor. Number of Inputs Twelve (12) switchable balanced mic or line level, Connectors 3.81 mm terminal blocks. Nominal Input Level +4 dBu line or -36 dBu mic level (software selectable) with 20 dB of headroom. Mic Pre-amp Gain +40 dB. Maximum Input Level+23 dBu. Input Impedance18 kΩ balanced, > 9 kΩ unbalanced, > 2 kΩ with phantom power engaged. Number of Outputs Nominal Output Level+4 dBu line level with 20 dB of headroom. For unbalanced analog output, do not connect the minus output terminal. Unbalanced configuration results in 6 dB lower output level. Maximum Output Level+24 dBu. Output Impedance Output Impedance Sample Rate48 kHz. Frequency Response20 Hz - 20 kHz, +/- 0.5 dB Refer Technical Specifications

2

-

25520

... More
Annual maintenance of FBQ Feedback Detection System , 12-segment LED input/output metering and input gain controls for easy level setting, Relay-controlled hard-bypass with an auto-bypass function during power failure (failsafe relay) Refer Technical Specifications

4

-

8624

... More
Annual maintenance of 3000 ANSI Lumens Projector WXGA(1280*800), Lamp Wattage 225W, with Lamp life of 5000Hrs, Inputs - 2 *HDMI, 2* VGA, 1* RCA, 1*Audio, 2* USBA, 1 * USB B, RJ45*1 with wireless adapter Refer Technical Specifications

4

-

22444

... More
Annual maintenance of motirized screen with Front Projection Fixed Screen: Size: 8 feet x 5 feet, Aspect Ratio: 16:9, fabric: Matte-White Finsh, Gain: 1.0. with black cloth backend Refer Technical Specifications B2

4

-

14928

... More
Annual maintenance of HDMI Transmitter Input 1 RJ−45 connector,Output1 HDMI connector Bandwidth support upto 4.95Gbps (1.65Gbps per graphic channel) Supports HDMI and HDCP power consumption 12V DC 250mA Refer Technical Specifications B6

6

-

13200

... More
Annual maintenance of HDMI receiver Input 1 RJ−45 connector,Output1 HDMI connector Bandwidth support upto 4.95Gbps (1.65Gbps per graphic channel) Supports HDMI and HDCP power consumption 12V DC 250mA Refer Technical Specifications B7

6

-

13200

... More
Annual maintenance of Full HD LED Display Screen Size 75" resolution1,920 x 1,080 Video icture Engine, 3D HyperReal Engine Clear Motion Rate400 Dynamic Contrast Ratio Mega Contrast Micro Dimming Wide Color Enhancer (Plus) Film Mode & natural support mode With Dolby MS10 DTS Studio Sound / DNSe, DTS Premium Sound 5.1 3D Sound, Auto Volume Leveler with Down Firing speakers HDMI 4 USB 3 Component In (Y/Pb/Pr)1, Composite In (AV) 1 (Common Use for Component Y) Ethernet (LAN) Audio Out (Mini Jack) Digital Audio Out (Optical) 1 RF In (Terrestrial / Cable input) 1/1(Common Use for Terrestrial)/0 IR Out HDMI 1.4 3D Auto Setting Wireless LAN Built-in Anynet+ (HDMI-CEC) Refer Technical Specifications B9 Inluding replacement of spares if necessory and repairs has to be carried out

2

-

65822

... More
Annual maintenance of digital podium with builtin interactive touch monitor with tilt facility screen size of 21.5 inch active matrix colour tft with 1920*1080 resolution and 16:9 with usb and vga interface to pc , lan port input selection switch annutonation features along with gooseneck mic, handheld wireless mic, lapel mic and headphone mic, aluminum cabinet, system with 3.0 Ghz processor and 3 MB cach Refer Technical Specifications B13

4

-

70864

... More
Annual maintenance of Audio dembedder Input-1HDMI Connector Output:1 HDMI connector, optical digital audio connector1 S/PDIF digital audio on an RCA connector1 unbalanced stereo audio on a 3.5mm mini connector Audio sour Supports up to 6.75 Gbps (2.25Gbps per graphic channel) 1080p @60Hz,36−bit Deep Color, Power consumption 5V DC 730mA. Refer Technical Specifications B8

6

-

26400

... More
XIII) CCTV SECURITY SURVELLIANCE SYSTEM: Providing annual maintenance of CCTV Security Surveillance system & maintenance scope including regular monitoring & periodical servicing following items for: (a) Bullet Camera - 16 Nos. (b) Network video recorder with 4 TB Hard disk - 1 No. (c) 4-" LED Monitor - 1 No. (d) 24 port - POE switch -1 No. (e) 8 port - POE switche -4 Nos. Including cabling network, power supply, voltage, RJ-45 Jack & End terminals etc., complete.

1

-

89320

... More
Providing AMC for 5 HP openwell submersible pumpst with starter of sump tank by ensures power supply, voltabe, current etc., and maintrenance as per original equipment manufacturers standards.

1

-

5720

... More
XIV) LABOUR CHARGES FOR ENGAGING TECHNICIANS / ELECTRICIANS: Annual Maintenance by Engaging Technicians/Electricians for Operation of Transformers, HT & LT, Diesel Generator-sets, Air-conditioning System & External Electrical Installations Services in Convention Centre. The work should be carried out as per the directions of the Engineer in Charge of the work. (365 Days x 3( 1electrician +1AV technician +1AC technician)

1095

-

567210

... More
Annual Maintenance by Engaging Helper for Operational of Transformers, HT & LT, Diesel Generator-sets, Air-conditioning System & External Electrical Installations Services in Convention Centre, GKVK. The work should be carried out as per the directions of the Engineer in Charge of the work.( 1 Electrical Helper +1AV Helper +1AC Helper)

1095

-

477420



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.