University Of Agricultural Sciences Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

University Of Agricultural Sciences - UAS Tender

Civil And Construction
Building Construction
Opening Date21 Mar 2022
Closing Date5 Apr 2022
Tender Amount₹ 7,09,10,501 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Filling available excavated earth (excluding rock) in sides of foundations upto plinth in layers not exceeding 20cms in depth, compacting each deposited layer by ramming after watering with lead upto 50m and lift upto 1.5m including cost of all labour complete as per specifications.

1043.5

-

226522.98

... More
Constuction of embankment with approved material gravel/murrum with all lifts and leads,transporting to site ,spreading ,grading to required slope and compacting to meet requirement Table 300-2complete as per specifcations,including cost of gravel/murrum,watering charges &compaction by vibratory roller to 95% of modified proctors density

819

-

287469

... More
Providing and injecting chemical emulsion for Pre- constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits, with chloropyriphos emulsifiable concentrates of 20% concentration, including cost of chemical, diluting in water to one percent concentration, labour, HOM of equipments, complete as per specifications. (Plinth area of the building at ground floor only shall be measured )

1092

-

125012.16

... More
Providing and laying in position plain cement concrete of mix 1:4:8 with OPC cement @ 180 kgs, with 40mm and down size graded granite metal coarse aggregates @ 0.85cum and fine aggregates @ 0.57cum machine mixed, concrete laid in layers not exceeding 15cms. thick, well compacted, in foundation, including cost of all materials, labour, HOM of machinery, curing complete as per specifications.

291

-

1720770.3

... More
Providing and laying in position plain cement concrete of mix 1:2:4 with cement @ 240kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.69cum and fine aggregates @ 0.459cum, machine mixed, concrete laid in layers not exceeding 15cms thick, well compacted, in foundation, plinth and cills, including cost of all materials, labour, HOM of machinery, curing complete as per specifications. GROUND FLOOR

6

-

38359.74

... More
First Floor

1

-

6458.09

... More
Second Floor

1.5

-

9784.34

... More
Terrace Floor

3.5

-

23056.91

... More
Providing and laying in position plain cement concrete of mix 1:3:6 with OPC cement @ 220kgs, with 20mm and down size graded granite metal coarse aggregates @0.84cum and fine aggregtes @ 0.56cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications.

22.5

-

129717.9

... More
Providing and laying in position reinforced cement concrete of design mix M25 with OPC cement @ 340kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.70cum and fine aggregates @ 0.47cum, with superplasticiser @ 3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15cms thick, vibrated for all works in foundation for footings, pedestals, retaining walls, return walls (any thickness) including attached pilasters, columns pillars, posts, struts, buttresses, bed blocks anchor blocks & plinths etc., including cost of all materials, labour, HOM of machinery, curing, complete as per specifications.

520.5

-

3663518.43

... More
Providing and laying in position reinforced cement concrete of design mix M25 with OPC cement @ 340kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.70cum and fine aggregates @ 0.47cum, with superplastisiser @ 3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15cms thick, vibrated for all works in Stilt Floor level for roof slabs, staircase, lintels and beams, retaining walls, return walls, walls (any thickness) including attached pilasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete as per specifications. GROUND FLOOR

269

-

1961036.9

... More
First FLOOR

270.5

-

1989500.45

... More
Second FLOOR

216

-

1602655.2

... More
Terrace FLOOR

22

-

164659

... More
Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 27.20kgs, with 12mm and down size graded granite metal coarse aggregates @ 0.05865 cum and fine aggregates @ 0.0391 cum, with superplasticiser @ 0.225 lts, machine mixed, well compacted for plain chajja of 8.5cms. average thickness, upto Ground Floor level, including cost of all materials, labour, HOM of machinery, finishing, curing, complete as per specifications. GROUND FLOOR

39

-

23267.4

... More
First FLOOR

39

-

23478

... More
Second FLOOR

24

-

14577.6

... More
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specifications.

584.5

-

162865.08

... More
Providing and removing centering, shuttering, strutting, propping etc., for columns, pillars, piers, abutments, post and struts, square / rectangular / polygon in plan including cost of all materials, labour complete as per specification. GROUND FLOOR

732

-

360495.36

... More
FIRST FLOOR

517.5

-

257652.9

... More
SECOND FLOOR

492

-

247613.76

... More
TERRACE FLOOR

183.5

-

93342.78

... More
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for columns, pillars,post and struts, circular or curved in plan including cost of all materials, labour complete as per specifications. GROUND FLOOR

40.5

-

39934.62

... More
FIRST FLOOR

28.5

-

28256.04

... More
Second Floor

4.5

-

4485.78

... More
Terrace Floor

2

-

2004.48

... More
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications. GROUND FLOOR

1243

-

391992.48

... More
First FLOOR

729

-

233834.04

... More
Second Floor

596

-

194391.36

... More
Terrace FLOOR

50

-

16578

... More
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for flat surface such as roofs, landing, balconies and likes, thickness upto 200mm including cost of all materials, labour complete as per specifications for heights up to 5.0m from ground level. GROUND FLOOR

927

-

400464

... More
FIRST FLOOR

945

-

413343

... More
SECOND FLOOR

731

-

323686.8

... More
TERRACE FLOOR

36

-

16135.2

... More
Providing and removing centering, shuttering, strutting, propping etc., for edges of slabs and breaks in floor including cost of all materials, labour complete as per specifications. GROUND FLOOR

61

-

49739.4

... More
First FLOOR

59

-

48108.6

... More
Second FLOOR

45

-

36693

... More
Terrace FLOOR

7

-

5707.8

... More
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for Chajja, corbels etc including edges including cost of all materials, labour complete as per specification. GROUND FLOOR

52

-

18139.68

... More
First floor

52

-

18420.48

... More
Second floor

52

-

18701.28

... More
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for vertical surface such as walls at any thickness, including attached pilasters, buttresses, plinth cills, and string courses cost of all materials, labour complete as per specifications. GROUND FLOOR

31.5

-

12179.16

... More
First floor

9

-

3528.36

... More
Second floor

12.5

-

4968

... More
Terrace floor

30.5

-

12286.62

... More
Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for Stairs (excluding landing) staircase including cost of all materials, labour complete as per specification. GROUND FLOOR

51.4

-

28866.24

... More
First FLOOR

51.4

-

29143.8

... More
Second FLOOR

51.4

-

29421.36

... More
Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design ( laps, hooks and wastage shall not be measured and paid ) cost of materials, labour, HOM of machinery complete as per specifications. -do- for TMT Bars Fe 500 GROUND FLOOR

95.7

-

9035071.45

... More
First floor

52.8

-

5027520.96

... More
Second Floor

42.85

-

4114715.81

... More
Terrace Floor

6.8

-

658470.38

... More
Providing and constructing granite / trap / basalt size stone masonry in foundation cement mortar 1:6, stone hammered dressed in courses not less than 20cms high, bond stones at 2.0m apart in each course including cost of materials, labour, curing complete as per specifications.

163

-

834634.98

... More
Providing and constructing granite / trap / basalt size stone masonry in basement with cement mortar 1:6, edges of stones chistle dressed in courses not less than 15 cms high, bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications.

41

-

273601.2

... More
– do – Providing ruled pointing to coursed stone masonry with cement mortar 1:3, 20mm deep, after raking joints to depth of 20mm nicely lining, including cost of materials, labour, curing complete as per specifications.

41

-

5894.16

... More
Provding and constructing load bearing wall with soild concrete blocks of size 400*200*200 having block density not less than 1800kg/m3 having a mimimun average compressive strength of 4.00N/mm2 confirming to Is2185 (part1):2005 and constructed with CM 1:4,as per IS 2572:2005 including cost of all materials labour chargers, scaffolding ,curing ,hire charges of machineries etc,complete as per sepecifications GROUND FLOOR

1349.7

-

1424945.78

... More
First Floor

1251.9

-

1369015.24

... More
Second Floor

1120.4

-

1267564.54

... More
Terrace Floor

418.4

-

489172.36

... More
Provding and constructing non load bearing wall with soild concrete blocks of size 400*100*200mm having block density not less than 1800kg/m3 having a mimimun average compressive strength of 4.00N/mm2 confirming to IS 2185 (part1):2005 and constructed with CM 1:4,as per IS 2572:2005 including cost of all materials labour chargers, scaffolding ,curing ,hire charges of machineries etc,complete as per sepecifications GROUND FLOOR

301.2

-

266580.07

... More
First Floor

244.9

-

226008.41

... More
Second Floor

241.3

-

231807.26

... More
Providing and constructing 75mm thick jaali wall using 200x200x75mm clay jaali with cement mortar 1:3 with 12mm deep recessed pointing with CM 1:3 after raking joints to depth of 12mm nicely lining ,including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. at all levels, leads and lifts ( actual lenght and height of jaali wall only be measured for payment) GROUND FLOOR

99

-

90684

... More
First Floor

99

-

93654

... More
Second Floor

99

-

96624

... More
Providing and fixing M.S.grill work for windows and ventilators using M.S. flats, or M.S. square rods, or combination of M.S. flats and square rods as per approved design, drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer, cost of materials, fixtures, labour and HOM of machinery complete as per specifications. GROUND FLOOR

2644.6

-

271335.96

... More
First Floor

2718.3

-

296512.16

... More
Second Floor

1962.3

-

226763.39

... More
Providing & fixing of glazed 3 Track - 2 Panel Sliding Windown With Mesh made out of multi chambered uPVC sections with TPv gaskets having isolated drainage and reinforced with GI throughtout the window. the sliding outer frame having a overall size of 108x45 mm with reinforcement of 1 mm thickness, sash with overall size of 39x58 mm with reinforcement of 1.5 mm thickness, mesh sash of overall size 30x48.5 mm reinforced with 1.5 mm of GI. Glazing bead for fixing kof glass shall be of size 20x18mm and coextruded with gasket. Fiber Glass mesh shall be provided in mesh shutter. Windows shall be provided with 5 mm plain float glass, standard hardware and single point locking system of flush lock. Wall thickness of frame, mullion & sash shall be 2-2.2 mm. Maximum possible size 2419mm x 2119mm

281.5

-

1586984.4

... More
Providing & of Fixed Louvered Ventilator made out of multi chambered uPVC sections with TPv gaskets having isolated drainage and reinforced with Galvanized Iron profiles through out the windown. The outer frame having a overall size of 60x55mm with reinforcement of 1 mm thickness and Mullion with overall size of 74x60mm with reinforcement of 1 mm thickness. Ventilator shall be provided with 4.5 mm Pin Head glass, standard hardware, Wall thickness of frame Mullion shall be 2-2.2 mm. GROUND FLOOR

10.5

-

51483.6

... More
First Floor

7.5

-

36774

... More
Second Floor

7.5

-

36774

... More
Providing and fixing stainless steel 304 grade for staircase railings,balconies ,ramps , with hand rail,50mm dia 16 guage hollow pipe welded to vertical hollow 50mm dia 16 guage, stainless steel vertical pipe spaced at 1.2m regular intervals and 5nos of 25mm dia. stainless steel hollow horizontal pipe arre welded to vertical 50mm dia hollow pipe.the entire assembly is fixed to staircase concrete by using expansion bolts by drilling concrete etc. complete including cost of materials ,labour,HOM of and electrical charges etc complete as per specifications. GROUND FLOOR

31.4

-

204184.15

... More
FIRST FLOOR

25.7

-

167285.41

... More
Second FLOOR

25.7

-

167451.95

... More
Providing, fabricating and fixing of stick type structural glazing using Aluminium Extrusions of 63.5mm x 58mm x 2.25mm of 1.73 kgs/rmt for vertical and horizontal members and 63.5mm x 38.1 x 1.33mm of 0.759 kg/rmt as outer frame with Electro Anodized Paint coated block finishing, using 8mm thick tuoghned glass with all necessary accessories like ultra glass Silicon sealant of Space tape, Masking tape, Galvanized anchor bolts, machine screws, 6mmm thick M.S. angle 50mm x 150mm x 6mm M.S.Galvanized L Brackets, structural sealant setting clocks, fasteners, wall connection etc., complete. at all levells GROUND FLOOR

9.5

-

68259.78

... More
FIRST Floor

14.5

-

104279.94

... More
SECOND Floor

14.5

-

104373.9

... More
Providing and fixing in position collapsible steel shutters with single or double leaf with vertical channel 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm size, with top and bottom rails of T iron sections of 40x40x6 mm with 38mm dia steel pulleys complete with bolt and nuts, locking arrangements, stoppers, handles on both sides with 7.5cms openings at 10 cms. c to c applying a priming coat of red lead paint. cost of materials, labour, HOM of machinery complete as per specifications. size of gate 2.4mx1.4m.

18

-

101282.4

... More
Providing white sal wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, HOM of machineries complete as per specifications.

6.2

-

405429.41

... More
Providing and fixing flush door shutter made out of solid core black board type, well seasoned chemically treated hard wood battens and internal frame with minimum 35 mm wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as per specification. - 35mm thick both side teak

8

-

42716.16

... More
Providing melamine polishing of approved shade including removing and refixing of doors shutters, glass, beading and existing polishing, scraping with blade and rubbing with zero size sand paper and applying sealer coat by way of spraying with necessary compressor and applying patty after rubbing with steel wool including two coats of approved shade of melamine polish etc., complete.

8

-

8968.32

... More
Providing and fixing flush door shutter made out of solid core black board type, well seasoned chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as per specification. - 35mm thick both side commercial GROUND FLOOR

85

-

325890

... More
First floor

72

-

276359.04

... More
Second floor

64

-

245928.96

... More
Wardrobe shutter providing and fixing openable shutters for wardrobe fixed to existing Ms frame work ,using 25mm thick ply wood ,with 25mm x6mm thick plain teak wood beading ,lipping 1.5 thick , finished in approved 1.5mm lamination sheet of approved clour ,shade and quality on all axposed sufaces and inrnal surface and internal surface ,including cost of brass fittings, parliametary hinges ,C handles, tower bolts , approved brand lock, ashesives ,synthetic resins, nails, screws etc, including cost of all materials ,labour charges ,complete as per specification. size considered :0.9x2.1

255.5

-

1557528

... More
Providing and fixing 65mmx90mm GRP Doorframe fabricated using E-Glass Chopped Strand Mat (CSM). U V-stabilized lsopthalic Gelcoat and lsopthalic resin. The thickness of the GRP skin shall not be less than 2.0 mm. The doorframe consists of four segmens, which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screws. The GRP frame shall be provided with wooden reinforcement of 61ocations fro high screw holding capacity for fixing metallic hold fast and shall be consolidated by filling with medium density foam/Plaster with fibre reinforcement Six Numbers of 260mmx25mmx5mm sizeS shaped M.S. flat hold fast shall be provided with the frame. GROUND FLOOR

79

-

38394

... More
FIRST floor

53

-

25986.96

... More
SECOND floor

53

-

26215.92

... More
Providing and fixing factory made single leaf rigid GRP Sandwich composite door shutter of 32mm thick, laminated with two GRP skins with wood grain finish, fabricated using U.V-stabilized lsopthalic Gelcoat and on layer of 45 gsm E-Glass Chopped strand Mat (CSM), impregnated with orthopthalic polyster resin. The thickness of the skins shall not be less than 1.5mm. Expanded Polystyrene (EPS) structural foam panel of 29mm thickness and a density of 20 Kg/m3 shall be used as core material. Wooden reinforcements made of Seasoned Salwood block of cross section not less than 28mmx32mm and also necessary salwood reinforcements for fixing the metal fittings such as tower bolts, aldrops, handles, etc, shall be provided. A structural adhesive compatible with EPS foam shall be used for bonding the core material, the Salwood reinforcement and the skins. The material and process for manufacturing the door shutters shall confirm to Standards and specifications and the door shutters tested in confiramation to IS 4020-1994. The finish of shutter will be plain colour White/Ivory/Beige/Light Grey or any other colour using high quality pigments. Exclusing cost of fixtures and inclusive of supply of shutters to respective work spot GROUND FLOOR

23.7

-

76788

... More
FIRST Floor

15.8

-

51260.26

... More
SECOND Floor

15.8

-

51328.51

... More
Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50m. including cost of materials, labour charges, complete as per specifications.

231

-

340789.68

... More
Providing and laying integral cement based waterproofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc., consisting of following application. (a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water proofing compound conforming to IS:2645 over the RCC slab after cleaning the surface before treatment. (b) Laying cement concrete using broken brick bats 25mm to 100mm size with 50% of cement mortar 1:5 admixed with proprietary water proofing compound conforming IS:2645 over 20mm thick layer of cement mortar 1:5 admixed with proprietary water proofing compound to required slope and treating similarly the adjoining walls upto 300mm height including rounding off junctions of walls and slabs. (c) After two days of proper curing, applying a second coat of cement lurry admixed with proprietary water proofing compound (d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 admixed with proprietary water proofing compound and finally finishing the surface with trowel and neat cement slurry and making of 300x300mm square. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test including cost of materials, labour complete as per specifications.

877.73

-

953636.09

... More
FOR TOILETS SUNK PORTIONS Providing INTEGRAL CRYSTALINE Waterproofing treatment to the sunken portion of Toilets. Using Crystalline Slurry of approved make @ 1.4kg per SQM in two coats (0.7 kg per sqm per coat) conforming to ASTM C 1202 & DINV 18998 standards. Methodology: 1. The first part consisting of grouting the porous slab area with non-shrink cementatious grout (if required). 2. The second part consisting of treating the cracks and construction joints by routing-out to a minimum 20mm x 20mm groove and treating it with crystalisation Mortar. First it is primed with crystalisation slurry and later filled with crystalisation mortar and later again a coat of crystalisation slurry. 3. The third part consisting of making required slopes at the interface joint of the toilet slab and masonry wall with crystalisation Mortar.. 4. The fourth part consisting of sealing / packing all joints of outlet pipes, etc. with CRYSTALISATION MORTAR 5. The fifth part consisting of providing and applying In-depth Crystalline Waterproofing System @ 1.4 kgs/sqm in 2 coats to permanently fix non-soluble crystalline growth throughout the capillary tracts and pores of concrete. The In-depth Crystalline waterproofing Material shall be applied by brushing as per manufacturer’s specification . on the entire toilet sunken slab and walls.

188.27

-

101665.8

... More
Providing and laying cinder concrete in cement 1:15 (1 cement : 15 cinder of 12.5mm nominal guage) on terraced roof or sunken slabs, laid to slope compacting , including cost of materials, labour, curing, complete as per specifications. At all levels

38.54

-

83038.28

... More
Providing and laying flooring using prepolished/Leather finish, water cut/gang saw 19mm thick granite laid over bed of 20mm thick 1:4 cm & jointed with neat cement slurry mixed with pigment to mach shade of granite slabs including laying POP on finished surface and cleaning the surface, including the cost of all materials and labours etc., complete as per specifications. - using silver grey granite / Multy Red / Ruby Red / Black / HassanGreen Granite of width not less than 900mm GROUND FLOOR

400.1

-

974683.61

... More
First FLOOR

364.3

-

888258.12

... More
Second FLOOR

352.1

-

859271.88

... More
Providing half nosing for 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification

229.6

-

44634.24

... More
Providing and fixing Vitrified glazed tiles of approved make, quality & colour of size 600 x 600 x 10mm thick fixed on bed of 12mm thick cement mortar for flooring, skirting and jointed with neat cement slurry mixed with pigment to mach shade of tiles, including providing spacers at required interval and removing stains, including cost of all mateirals, mortar, labour, etc , Complete as per specification. GROUND FLOOR

507.5

-

493290

... More
First floor

530.5

-

516781.27

... More
Second floor

368

-

359285.76

... More
Providing Ceramic tiles of approved make,shade and size for flooring, treads of steps and landings laid on a bed of 12mm thick, cement mortar 1:3 mix, flush pointing with white cement using colour pigment , including cost of materials, labour, curing, complete as per specifications. - for Ceramic Tiles of size 30x30cms 6mm thick GROUND FLOOR

133.8

-

177697.1

... More
First Floor

103.5

-

137679.84

... More
Second Floor

103.5

-

137903.4

... More
Providing skirting, dado, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over rough plaster surface (excluding cost of rough plastered surface which should be measured and paid separately) using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOOR

337.5

-

432536.62

... More
First Floor

209.5

-

268945.62

... More
Second Floor

209.5

-

269398.14

... More
Providing and laying platform using prepolished, water cut/gang saw 40mm thick telephonic Black Granite. laid on existing vertical supports and fixing in CM 1:3 proportion, incluiding cutting to required shape, pattern with paper joints, including full rounding for nosing, finished with cement mortar, pointed with colour pigments to match the colour of slab making through jointing with sealant, making holes 25mm x12mm grooves in joints including curing. GROUND FLOOR

47.63

-

181327.41

... More
First Floor

45.06

-

171640.75

... More
Second Floor

45.06

-

171738.08

... More
Providing 15mm thick cement plaster in single coat with cement mortar 1:6, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. Internal GROUND FLOOR

3034.6

-

708882.56

... More
First Floor

2833.5

-

680266.68

... More
Second Floor

2497.3

-

615734.29

... More
Terrace Floor

103.5

-

26860.32

... More
KSRB 15-5.2 : Providing rough cement plastering 15mm thick in single coat with cement mortar 1:6, to brick/block masonry for base of Dadoing works with sand of approved quality, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. GROUND FLOOR

337.5

-

73008

... More
First floor

209.5

-

46676.6

... More
Second floor

209.5

-

48034.16

... More
Providing 15mm thick cement plaster in single coat with cement mortar 1:6, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. External GROUND FLOOR

737

-

172163.2

... More
First Floor

737

-

181714.72

... More
Second Floor

586

-

152078.72

... More
Terrace Floor

840

-

228883.2

... More
Providing 12mm thick cement plaster in single coat with cement mortar 1:4, to ceiling including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. GROUND FLOOR

927

-

235430.19

... More
First FLOOR

945

-

246125.25

... More
Second FLOOR

731

-

195125.83

... More
Terrace FLOOR

36

-

10076.04

... More
Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (Length of mesh only be measured for payment)

7383.5

-

287070.48

... More
Providing applying two coats of wall putty to inside plastered walls and ceiling using white cement putty. Scrapping and levelling the surface using steel blade and preparing the surface even and smooth by using different grade sand papers, including cost of all materials, cost of labour and scaffolding etc., complete as per the specification.

11111

-

935990.64

... More
Providing and applying painting in two coats with plastic emulsion paint of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface , free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications. with primer

8472

-

823478.4

... More
Providing and applying painting in two coats with plastic emulsion paint of approved brand on ceiling surface to give an even approved shade after thoroughly brushing the surface , free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications. with primer

2639

-

270761.4

... More
Providing and finishing external walls in two coats over one coat of primer with antifungal paint of approved brand and shade to give an even shade after thoroughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter , cost of materials, labour, complete as per specifications. GROUND FLOOR

737

-

143272.8

... More
First Floor

737

-

149640.48

... More
Second Floor

586

-

124044.48

... More
terrace Floor

840

-

185068.8

... More
Providing and applying synthetic enamel metal paint two coats (excluding priming coat) over new steel surface brushing to give an even shade after cleaning oil, grease, dirt and other foreign matter, including cost of materials, labour complete as per specifications.

294

-

30164.4

... More
Applying red lead ready mix priming coat over new steel or other metal surface including preparing the surface after throughly cleaning oil, grease, dirt and other foreign matter, and scoured with wire brushes, fine steel wool, sand papers including cost of materials, labour, complete as per specifications.

293.5

-

12996.18

... More
Applying priming coat over new wood surface and / or wood based surface after preparing the surface after throughly cleaning oil, grease, dirt and foreign matter, sand papering and knotting liquid wood filler, for varnish including cost of materials, labour, complete as per specifications.

530.5

-

28647

... More
Providing and applying painting two coats (excluding priming coat) on new wood surface and / or wood based surface with enamel paint to give an even shade, cleaning the surface of all dirt, dust and foreign matter, sand papering including cost of materials, labour complete as per specifications. with primer

530.5

-

55575.18

... More
Providing and making plastering grooves of 12mm with 1:3 finishing as directed etc, complete

9724.5

-

97245

... More
Providing drip moulding with plastering of 25mmx 100mm in cement plaster 1:4 with rendering for projected surface ,provding and removing the cost of scaffolding inculding cost of material , labours curing as per specifications

470.4

-

11760

... More
ELECTRICAL WORK : LT ELECTRICAL WORKS PVC CONDUITS & ITS ACCESSORIES Open conduit System Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. a) 19/20 mm dia 2mm thick

250

-

12500

... More
b) 25mm dia 2mm thick

1325

-

86125

... More
c) 32mm dia 2.5mm thick

100

-

9200

... More
Concealed conduit System Supplying heavy gauge PVC conduit pipe ……mm dia ......mm thick confirming to IS 2509 with suitable size bends, metals/PVC junction boxes, adhesives paste etc., and running before concreting the slab . The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. a) 19/20 mm dia 2mm thick

700

-

28000

... More
b) 25mm dia 2mm thick

6800

-

360400

... More
c) 32mm dia 2.5mm thick

450

-

37350

... More
Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc. By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary a) 19/20 mm dia 2mm thick

150

-

7650

... More
b) 25mm dia 2mm thick

1700

-

91800

... More
c) 32mm dia 2.5mm thick

100

-

8100

... More
Supplying and fixing PVC/metal conduit deep junction box. a) 19/20mm deep junction box

100

-

4300

... More
b) 25mm deep junction box

380

-

17860

... More
c) 32mm deep junction box

30

-

1800

... More
Extra for Groove cutting in brick wall/cc floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing the wall upto wall surface complete. a) upto 50mm conduit in CC Floor

50

-

1900

... More
Supplying and fixing Metal fan box with round hook.

160

-

13600

... More
Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.5Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. a) Short point up to 3Mtr from tapping point to out let via switch box

350

-

56000

... More
b) Medium point above 3Mtr up to 6Mtrs from tapping point to out let via switch box

170

-

42500

... More
c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box

100

-

37500

... More
d) Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switch box

60

-

28500

... More
e) Three outlet in a row, above 6Mtr up to 10Mtr from tapping point to out let via switches box

35

-

23625

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. a) 1.5 sqmm

4700

-

96350

... More
b) 2.5 sqmm

11000

-

352000

... More
c) 4 sqmm

4400

-

198000

... More
d) 6 sqmm

1650

-

115500

... More
e) 10 sqmm

2100

-

241500

... More
Supplying and Drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130-1984 and (virgin) PVC insulation and sheathed suitable for working voltage upto 1100volts as per IS-694:1990. a) 4Cx2.5Sqmm

300

-

34500

... More
SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall a) 1-3 Way

210

-

19950

... More
b) 4 Way

150

-

15750

... More
c) 6 Way

148

-

18500

... More
d) 8 Way

20

-

2900

... More
e) 10-12 Way

15

-

2475

... More
f) 16-18 Way

10

-

1800

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. a) 1 to 3 Module

210

-

23100

... More
b) 4 Module

150

-

18750

... More
c) 6 Module

148

-

25900

... More
d) 8 Module

20

-

4000

... More
e) 10-12 Module

15

-

3450

... More
f) 16-18 Module

10

-

2700

... More
Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 a) 6 Amps one way

950

-

66500

... More
b) 6 Amps Two way

20

-

1900

... More
c) 6Amps 3way socket.

280

-

29400

... More
d) Stepped fan regulator

160

-

46400

... More
e) 32A,DP,Switch

15

-

2730

... More
f) 16Amps one way switch

50

-

5750

... More
g) 6/16Amps universal socket

65

-

10530

... More
CONTROL SWITCH GEARS & ACCESSORIES Supplying push button operated, direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 400/440 volts 3 phase motor/single phase motor upto 5 HP.

4

-

5520

... More
Supplying and fixing regular MCB distributionpanel confirming to IS 8828 , on wall/wood board/ flush mounting using required clamps, bolts, nuts etc.. With provision for fixing of suitable type capacity ELMCB / MCb's as an incomer for 3 phase double door with necessary bus bar completely wired to use on 440volts 3 phase 4 wired powder coated painting etc.. complete with provision for fixing of single/three phase suitable capacity ELMCB/MCb's as outgoings confirming to IS8828 . 4 way

3

-

21000

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. a) 5-32Amps SP

170

-

73780

... More
b) 5-32Amps DP

12

-

10908

... More
c) 5-32Amps TPN

15

-

25725

... More
d) 40Amps TPN

5

-

11870

... More
e) 63Amps TPN

2

-

4794

... More
Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure a) Double Door 4 Way SP & N

2

-

2200

... More
b) Double Door 8 Way SP & N

8

-

11600

... More
c) Double Door 4 Way TP & N

5

-

13250

... More
d) Double Door 6 Way TP & N

4

-

13320

... More
Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/ panel board. a) 32-40Amps 4 pole

10

-

28000

... More
b) 63Amps 4 pole

2

-

6400

... More
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron ….and M.S. flat with bolts, washers etc… and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6

25

-

6375

... More
Supplying and fixing of metal Socket set of 2 pole and earth plugs and socket for incorporating SP and TP MCB (without MCB). The entire Plug and Socket shall be mounted in athermoplastic / powder coated metal box & wired completely. SP & N 20Amps

2

-

1616

... More
TP & N 30Amps

2

-

2840

... More
L.T. U.G. CABLES Supplying fixing and wiring earth electrode for grounding of DG Sets etc. using 40mm dia 2.9mm thick 2.5mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.

15

-

62250

... More
Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. a) GI strip 25x3mm

200

-

15000

... More
b) GI strip 25x6mm

300

-

34500

... More
c) 600x600x3mm GI Plate

15

-

11400

... More
Supplying, Fixing & proper termination of vertical Air-termination using Gunmetal ball with finials of 5 spikes mounted on 2 mtrs long copper rod, mounted at the highest point of the building, with base plates, connection with horizontal conductor, necessary civil works, etc.

1

-

7500

... More
Supply & fixing Test Link as per specification & drgs. and grouted to wall at 1200 mm. above ground level complete with all fixing accessories, clamps, screws etc, enclosed in M.S box.

1

-

3500

... More
Supplying & Fixing Chemical earthing for grounding, conduits, IC cut outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10 ft copper bonded rod with backfill compound

2

-

14520

... More
Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.. 8 SWG Copper wire..

100

-

10500

... More
Supplying of 1.1KV LT UG Aluminium cable XLPE or heat resistant PVC insulated, PVC extruded inner sheathed, armourd UG LT cable as per the IS - 1554 (part-1) or IS-7098 part-1, Armoring strip thickness in average + 5% and resistivity 14 Ohms/Kms (Max) as per IS -3975. a) 2 core 10 sq.mm

100

-

9500

... More
b) 4 core 10 sq.mm

100

-

13000

... More
c) 4 core 16 sq.mm

100

-

15000

... More
d) 3.5 core 50 sq.mm

100

-

30000

... More
e) 3.5 core 150 sq.mm

300

-

216000

... More
Labour charges for laying of 1.1 KV class UG cable in the existing trench GI pipe / stoneware pipe / on wall / on pole as required. On wall / Structure. a) 6 sqmm to 16 sqmm

300

-

9000

... More
b) 25 sqmm to 75 sqmm

260

-

9100

... More
c) 75 sqmm to 150 sqmm

300

-

12000

30

-

2040

... More
b) 25mm

4

-

336

... More
c) 32mm

6

-

702

... More
d) 45mm

4

-

776

... More
Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. a) 150x50mm

30

-

12750

... More
b) 300x50mm

30

-

15900

... More
Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. a) 1.5 sq.mm

800

-

2400

... More
b) 2.5 sq.mm

350

-

1400

... More
c) 4 sq.mm

250

-

1750

... More
d) 6 sq.mm

50

-

350

... More
e) 10 sq.mm

100

-

800

... More
f) 16 sq.mm

20

-

248.8

... More
g) 25 sq.mm Long barrel

10

-

200

... More
h) 50 sq.mm Long barrel

20

-

1200

... More
i) 150 sq.mm Long barrel

10

-

2350

... More
FANS Supplying exhaust fan of 1440RPM heavy duty with bracket blades complete for lighting duty suitable to operate on 230V 50Hz, AC supply.. 12" sweep (300mm)

30

-

63000

... More
Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value ≥ 4.2 CMM / Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.. 5 STAR 48" Sweep 5 Star (1200mm)

160

-

464000

... More
Supplying wall mounting fan suitable to operate at single phase 230v AC supply. 400mm Sweep

5

-

14000

... More
Fixing all types and all capacities fluorescent /false ceiling/spot light/CFL/LED fittings indoor on the wall / ceiling / rafters / girders using 23 / 0.00076 " twin twisted PVC insulated wires, required nos of round blocks and clamps. On wall / ceiling / Rafters / Girders

600

-

66000

... More
Fixing a ceiling/wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing a 5 amps ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.

165

-

24750

... More
Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.

30

-

12000

... More
LED LUMINAIRS / LIGHT FIXTURES & ACCESSORIES Supply of 15W LED bulk head fitting with guard, Acrylic glass and suitable driver.

30

-

45000

... More
Supplying of 2' feet - LED PVC Square Batten …W with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with CRI > 8. Power Input : 220-240V @ 50 Hz & power factor . 0.9 along with CE approved drivers. 2 years warranty against any manufacturing defect working under standard electrical condition. a) Led light fitting 2' - 9 / 10 watts

300

-

75000

... More
b) Led light fitting 4' - 20 / 22 watts

135

-

50625

... More
c) Led light fitting 2 X 4' - 20 / 22 watts

5

-

3125

... More
Supplying of Surface / recess mounting non integrated type LED down light …W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power / COB with CCT 6500 degree K, CRI >70%. efficacy >100 lumen per watt, 120degree beam spread, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit THD Less then 20%, Life as per LM 79, The operating input voltage should be between 130 to 275 volts, BIS Approved and tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 10-12W

120

-

163200

... More
Supply of LED Flood / Hi bay light with ......W system power consumption pressure die cast aluminum housing with powder coating with IP 65 protection. 1 200-270v voltage with electronic driver, PF>0.9, should meet ANSI 2G vibration test, compliance to UL/CE with class 1. System rating shall be 50K hr. @ lumen maintenance of 70%. system efficiency >80ml/w. Overload & short circuit protection ensures reliable operation in spite of problem in output side. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .........W system power consumption. LEd efficiency > 130ml/w at 1w and fixture efficiency > 75ml/w with CRI > 75. luminaire Manufacturer should have in-house facility accredited by NABL/CPRI & any government certified agency & design & development facility certified by ISO 9001:2008. Housing with supplier word mark/name shall be engraved / embossing on the die cast housing / body part. 2 years warranty against any manufacturing defect working under standard electrical condition as mentioned above should be given by LED manufacturer. 70-80W FLOOD LED LIGHT

10

-

68000

... More
Design, manufacture, supplying, fixing in position, testing and commissioning of following MV switchgear panels made up of 14/16G, suitable for 415 V, 3 phase, 4 wire, 50 Hz power distribution system. The incoming and outgoing feeders shall be accommodated in a modular multitier arrangement and shall be interlocked to avoid paralleling, adequate size cable alley, painting, earthing, numbering, danger plate etc. as required as per specifications and drawings. The panels should be with all items as per SLD and Specification. Supply, installation, testing & commissioning of MAIN GIRL'S HOSTEL BLOCK EB,DG AUTO CHANGEOVER PANEL, IP 52 Ingress Protection suitable for 415 V, 3 ph., 4 wire, 50 Hz, power distribution system as per Single Line Diagram. Fabricating supplying and mounting MS box made out … SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint and Powder coating. etc., complete. 14SWG

90000

-

36000

... More
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron… and M S flat …….. With bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75x75x6mm

4

-

1840

... More
Supplying …….amps rated 3 phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M S flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 1x30x6mm Aluminum Strips.

4

-

8200

... More
250 Amps 1x30x10mm Aluminum Strips.

4

-

11400

... More
Supplying of multi function Meter digital three line back light LCD type display of voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required wit communication Port and class 0.5s accuracy.

1

-

7750

... More
Supplying, fixing and wiring 50/5A to 400/5A 5VA burden class - 1 current transformer.

2

-

1400

... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220V AC, 50Hz 12/24V DC.

3

-

1290

... More
Supplying, fixing and wiring 3 Digit Digital Ammeter/Voltmeter

1

-

1185

... More
Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50Hz AC with latest microcontroller based, digital read out of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail / flush mounting panel board.

1

-

7700

... More
Supply and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of overload and short circuit with thermal magnetic/micro processor releases and earth fault as per IS-13947. (Icu=Ics) THREE POLE 63-100Amps 25kA

6

-

27180

... More
FOUR POLE 125Amps 25kA

1

-

8250

... More
FOUR POLE 250Amps 25kA

1

-

17100

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60899 6-32 Amps SP

4

-

1736

... More
6-32 Amps TPN

4

-

6860

... More
40 Amps TPN

2

-

4748

... More
63 Amps TPN

2

-

4794

... More
Supply and fixing of fully enclosed Automatic Transfer Switch (ATS) Pre-wired with flexible settings and seamless transfer between twom power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection, Adjustable Time Delay (0.1 sec to 3 hours). Double Break Contact System offering High Short-time Withstand (lcw) with necessary Terminal Shrouds, Phase Barriers & Source Separator, Protections for UV/OV phase sequence, single phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 volts. 250Amps

1

-

95000

... More
Supply and fixing of 4 pole contactor with No/NC contacts on existing wood/ panel board using necessary bolts, nitsm washers and wiring etc, complete with AC-3 rating and as per IS- 13947 25Amps

2

-

3680

... More
Supplying, fixing and wiring heavy duty low voltage capacitors confirming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery.

20

-

8600

... More
Supplying, fixing and wiring Automatic Power Factor controller fully, static units controilled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, comprehensive displays with large, three place LED display, long term memory for settings, protection for over voltage, power facor correction fault and no voltage, to connect / disconnect banks, with automatic recognition or with standard programs.

1

-

18000

... More
Supply, installation, testing & commissioning of MAIN FIRST & SECOND FLOOR SUB PANELS (QTY 2 NOS), IP 52 Ingress Protection suitable for 415 V, 3 ph., 4 wire, 50 Hz, power distribution system as per Single Line Diagram. Fabricating supplying and mounting MS box made out … SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint and Powder coating. etc., complete. 14SWG

90000

-

36000

... More
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron… and M S flat …….. With bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75x75x6mm

2

-

920

... More
Supplying …….amps rated 3 phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M S flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips.

2

-

4100

... More
Supplying of multi function Meter digital three line back light LCD type display of voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required wit communication Port and class 0.5s accuracy.

2

-

15500

... More
Supplying, fixing and wiring 50/5 to 400/4Amps 5VA burden Current Transformer. Class 0.5 accuracy with tape wound.

4

-

1872

... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220V AC, 50Hz 12/24V DC.

6

-

2580

... More
Supplying, fixing and wiring 3 Digit Digital Ammeter/Voltmeter

2

-

2370

... More
Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50Hz AC with latest microcontroller based, digital read out of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail / flush mounting panel board.

2

-

15400

... More
Supply and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of overload and short circuit with thermal magnetic/micro processor releases and earth fault as per IS-13947. (Icu=Ics) FOUR POLE 63-100Amps 25kA

2

-

12800

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60899 6-32 Amps SP

8

-

3472

... More
6-32 Amps TPN

8

-

13720

... More
40 Amps TPN

4

-

9496

... More
63 Amps TPN

4

-

9588

... More
Supplying, erecting, testing and commissioning of OFF-LINE UPS System suitable for operation on 230V Input and 230V, Output, 50Hz, A/C supply with all accessories complete and excluding batteries and wiring complete. 3 KVA OFFLINE UPS

1

-

31100

... More
Supplying, installation, testing & commissioning of 12volts DC AH Batteries in poly propylene container for UPS Low maintenance Tubular/smf batteries. 12V, 75-80 AH Capacity. Acid battery.

4

-

34800

... More
CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 1/3" progressive scan CMOS, 4.0 megapixel, IP based Colour camera, Up to 30 m IR range, Color: 0.01Lux, 1000TVL, Digital WDR (Wide Dynamic Range), 3D DNR (Digital Noise Reduction), PoE (Power over Ethernet/1 RJ45 10M/100M self-adaptive Ethernet port), IP67, Motion detection, Alarms (Video tampering, network disconnected, IP address conflicted), Protocols (TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, RTCP, NTP, UPnP, SMTP, IGMP, 802.1X, QoS, IPv6, Bonjour), Standard (ONVIF(PROFILE S,PROFILE G),PSIA,CGI,ISAPI), General Function (Anti-flicker, heartbeat, mirror, password protection, privacy mask, watermark), with base box, other necessary accessories. The cost shall includes end terminations.

24

-

156000

... More
Supply, Installation, Testing & Commissioning of 24port 10/100/1000 Smart POE Switch with 4 SFP (192W)for camera connection including all necessary accessories.

2

-

37000

... More
Supply, Installation, Testing & Commissioning of NVR (Networkable Video Recorder) - 32Channel NVR, Up to 32ch IP cameras input, Up to 5 Megapixels resolution recording, HDMI and VGA output at up to 1920�1080P resolution, HDD quota and group management 4 SATA, 3 USB, interface, 1 RJ-45 10 /100 /1000 Mbps self-adaptive Ethernet interface, 4TB HDD/30Days recording storage, whichever is higher, support 10TB external HDD connected through SATA Ports DVR should have 2 external SATA Port, Alarm in (32) Alarm out (32), 100~240VAC, 6.3A, 50~60Hz, rack mountable, Password protection, Upto 32 simultaneous views from different DVRS on same LAN on single screen, etc. with all necessary Accessories.

1

-

75000

... More
Supply, Installation, Testing & Commissioning of HDMI, Display Monitor 32" high resolution, Monitor with all mounting bracket accessories.

1

-

32000

... More
Supply, laying and termination of CAT6 UTP, cable for IP BASED Camera power and video connection in existing Conduit / pipe.

1100

-

31900

... More
NETWORKING AND COMMUNICATION : Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. a) TV/ Telephone socket

25

-

4875

... More
b) RJ45/I.O. outlet

150

-

102000

... More
Supplying and drawing UTP-CAT 6 LAN cable.

2700

-

78300

... More
Supplying and Drawing PVC flexible one pair telephone unarmoured tinned copper cable. a) 2 Pair

750

-

10875

... More
b) 5 Pair

100

-

4800

... More
c) 20 Pair

20

-

3000

... More
Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable. RG-6.

250

-

8750

... More
Supplying and fixing of switch mounting rack with power manager & cable manager. 12U with 450mm depth

3

-

22800

... More
Supplying and fixing of power strip.

3

-

3000

... More
Supplying and fixing of fan.

3

-

2325

... More
Supplying fixing of Network Switches. 48 Port 10/100/1000

3

-

56100

... More
Supplying & fixing of ….mtrs Cat6 Patch Cable - a) 1 mtr

150

-

23700

... More
b) 2 mtr

15

-

3570

... More
Supplying & fixing of Patch Panel for LAN cabling. 48 Port 10/100/1000 Patch Panel

3

-

67500

... More
Supplying and Fixing of MDF Krone junction box with KRONE module / Telephone cable termination. 20 pair

2

-

700

... More
Supply and laying 6 Core Multimode OM3 outdoor Fiber Cable.

300

-

75000

... More
Supply and providing 12F, 1U, LC MM OM3, Loaded with Pigtails, Splice tray, adapter & splice protectors

1

-

12500

... More
Supplying, installing, testing and commissioning of Diesel Generator set with following specification. Power rating as per standard reference condition as per BS 5514/ISO 3046/ISO 8528 & IS 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes : Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with Mechanical governor, A1 Class. Spin-on lube oil filter. Spin-on dual fuel filter with water separators, Turbocharger, Charge air cooler, silencer (Hospital grade), Dry type air cleaner, shutoff coil, flysheel and flywheel housing. First fill of lube oil and coolant. Safety form low lube oil pressure. Safety for high water temperature, permissible overload of 10 % for one hour in 12 hours of operation.Capacity of Fuel Tank : Fuel tank suitable for 8 hours of operation Alternator: Alternator is suitable for operation at 1500 RPM, 415 Volts, 0.8 pf (lag) suitable got 50 Hz, 3 phase, 4 wire systems, conforming to IS/IEC 60034-1. The alternator is brushless type, screen protected,revolving field, self excited, self regulated through an AVR. The alternator shall have � 1.0 % voltage regualtion (max) in static conditions - IP:23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads.Control Panel : The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather -proof and long lasting finish. The control panel consists of the following parts: PS0500 Controller, Aluminium bus bars with suitable capacity within / outgoing terminals, indicating lamps for 'Load On' and 'Set Running' instrument fuses duly wired and ferruled. MCCB / ACB of suitable rating with overload and short circuit protections Genset Controller : Microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and proformance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x2 line alphanumeric LCD display with LED backlight. Operator interface, provide a record most recent fault conditions. Fault history stored in the control non volatile memory, provide alternator data. Voltage (1ph or 3 ph line to line and line to neutral voltage, current (1ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, control includes provison for service adjustment and calibration of DG control functions, voltage frequency selection. Configurable input and output set up, meter calibration, engine controls, power start operates on 12 VDC batteries, - auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode.Engine Starting : The control system supports automatic engine starting, primary and back up start disconnects are achieved by battery charging alternator feedback or main alternator output frequency. Controller provide configurable time delay of 0-300 secs to start after remote start signal and time delay of 0-600 secs prior to shut down after stop signal. Sleep mode increase battery life. Configurable current settings from low to minimize current draw when genset is not working. Engine Protective functions include, configurable alaram output, emergency stop: Annunciated whenever an emergency stop signal is received by the control. Low lube oil pressure warning and shutdown, high engine water temp warning and shutdown, low coolant temp warning, sensor failure indication, low and high battery voltage warning, weak battery warning, fail to start shut down, cracking lockout; control will not alllow the starter to engage or to crank the running engine. Two point lifting for easy handling at customere site, designed to have optimum serviceability, air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship, Powder coated for long lasting service life and superior finish with UV resistant powder coating can withstand exreme environment. Use of special hardware for longer life, insulation material meets exacting IS 8183 specifications for better sound attenuation, Flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling point inside the enclosure. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD-2 specifications, PCB norms and KSGEI Acts and Rules. 62.5Kva

1

-

514500

... More
Supplying, erection, testing & commissioning of AMF Panel for 62.5 KVA DG Set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium bus bar with the accommadation for ……amps 4 pole contactor for alternator with thermal O/L relay,....Amps 4 pole contactor for mains, MCCB / ACB for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/engine speed, Voltage/ampere/Frequency/KVA, Running-hour count, No of starts, Fault indication, over/under speed, fails to start, low oil pressure, high engine temperature, under/over voltage, over current, earth fault relay, with indications for mains on, load on mains, battery charger on push buttons AMF module by pass mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. 62.5KVA

1

-

89500

... More
Providing and fixing white vitreous china clay,flat wash basin size 550 x 400 with a Single 15mm C.P brass pillar taps with C.I/M.S brackets, 32mm dia CP brass waste of standard pattern, painting of fittings and brackets,cutting and making good the wall and floor wherever required,including cost of materials,labour complete as per specification.

32

-

104405.76

... More
Providing and fixing white vitreous china clay,water closet european type(pedestal ,type P trap )with black solid plastic seat and lid,CP brass hinges,rubber buffer,10ltrs white glazed/vitreous china clay low level,flushing cistern(all are approved make) with fittings,CI/MS brackets,40mmdiameter flush bend with fittings and clamps,overflow arrangement with specials and 25mm mosquito proof coupling of approved design,painting of fittings and brackets,cutting and making good the wall and floor wherever required, including cost of materials,labour complete as per specifications. Make : Hindware

22

-

117754.56

... More
Providing and fixing CP. Health faucet with flexible hose,CP Bibcock with 2 in 1 connectvity, wall flange, supporting hook with screws, fixing materials and sealant to all sides of wall flange complete.

22

-

60060

... More
Providing and fixing in posiion brass bib cock of approved quality 20mm normal bore including cost of materials, labour and HOM of Equipments with all leads complete as per specifications.

30

-

5605.2

... More
Providing and fixing in position brass stop cock of approved quality 20mm nominal bore inlcuding cost of all materials, labour, HOM of equipments with all leads complete as per specifications.

66

-

10050.48

... More
Providing and fixing 600x450mm bevelled edge mirror of superior glass with 6mm hard board backing and fixed to wooden cleats with C.P screws, washers, including cost of materials, labour complete as per specifications.

32

-

39985.92

... More
Supplying , shifting to the place of installation and fixing testing and commissioning of stainless steel soap dish 150 x 150mm including cutting and setting in walls with cement joints and making good the wall. Make : JAQUAR Model No- ACN -1131N

41

-

25830

... More
Providing and fixing 2 in 1 Wall Mixer with complete fitting comprising of with provision for with long bend spout for bucket with wall flange complete.

19

-

100320

... More
Providing and fixing shower head Arm with rose long bend free flow with fitting wall flange complete, including teflon with fixing.

20

-

21600

... More
Providing and fixing of CP Brass towel Rail 600mm length 20mm dia with cp bracket fixed to wodden cleats with CP brass screw including cost of material, labour complete as per specification.

20

-

14558.4

... More
Providing and fixing of sink confirming to IS 13983: 1994 of size 500 x 1000mm bowl depth 220mm, with single bowl drain boards, MS/CI Brackets, Stainless steel plug 40mm, painting of fittings, with length, 20 mm dia, with CP brackets,painting of fittings and brackets, and cutting making good the wall and floor whereever required including cost of material, labour completely as per specifications.erever required, including cost of materials, labour complete as per specifications.

2

-

19137.6

... More
Supplying & fixing of CP sink cock with swivel spout with wall flange etc complete.

2

-

5112

... More
Supplying, Installing in position C P grab bar with pair of fixing screws and fixing material complete. Make : Jaquar Model No- AHS-1507

4

-

6600

... More
Providing and fixing white china clay,flat back lipped front urinal basin of 430X260X350mm in the range of two 7.5 Litres PVC automatic flushing cistern,CI/MS brackets,standard flush pipe and CP brass spreaders with brass unions and GI clamps complete painting of fittings and brackets,cutting and making good the wall and floor wherever required,including cost of materials,labour complte as per specification.

18

-

80967.6

... More
Providing and fixing to wall, ceiling and floor , mediumdensity polyethylene pipes 6.00 kgf /sqcm working pressure 40 mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Make: Astral / Ashirvad / supreme

76.8

-

18911.23

... More
Providing and fixing to wall, ceiling and floor , mediumdensity polyethylene pipes 6.00 kgf /sqcm working pressure 50 mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications.

4.6

-

1296.65

... More
Providing and fixing to wall, ceiling and floor , mediumdensity polyethylene pipes 6.00 kgf /sqcm working pressure 75 mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications.

181

-

63726.48

... More
Providing and fixing to wall, ceiling and floor , mediumdensity polyethylene pipes 6.00 kgf /sqcm working pressure 110 mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications.

174

-

84564

... More
Providing & fixing, testing and commissioning u PVC multi inlet floor trap 75mm dia conforming to IS 13592 with required P C C support placed to required level as per site condition complete..

53

-

17903.93

... More
Supplying and fixing PVC `P' trap 110mm dia, of self cleansing design with or without vent arm complete including cutting and making good the walls and floors.

2

-

844.88

... More
Providing & Fixing in position heavy duty C P grating 125mm dia, with frame of below mentioned sizes including jointing and fixing material complete.

55

-

15510

... More
Providing and grouting sleeves made in beam/ slab to draw waste and soil lines at all floor level of the below mentioned sizes , including condcting water ponding test to ensure zero leakage with all leads and lifts complete Size : 150 mm dia

30

-

21600

... More
Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.) 20 mm dia pipe nominal OD pipes

216

-

63043.92

... More
Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.) 25 mm dia pipe nominal OD pipes

120

-

43669.2

... More
Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and good the walls etc.) 32 mm dia pipe nominal OD pipes

90

-

41805.9

... More
Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications.

8

-

2903.04

... More
Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) 25mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications.

8

-

3879.36

... More
Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) 32mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications.

6

-

5378.4

... More
Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work) 20 mm dia pipe nominal OD pipes

152

-

23967.36

... More
Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work) 25 mm dia pipe nominal OD pipes

155

-

29964.6

... More
Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work) 32mm dia pipe nominal OD pipes

169

-

41249.52

... More
Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work) 40mm dia pipe nominal OD pipes

114

-

35951.04

... More
Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work) 50 mm dia pipe nominal OD pipes

105

-

48988.8

... More
Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications.

12

-

4354.56

... More
Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) 25mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications.

6

-

2909.52

... More
Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) 32mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications.

8

-

7171.2

... More
Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) 40mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications.

6

-

6739.2

... More
Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) 50mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Make: Zoloto

4

-

7512.48

... More
Providing and placing on terrace, polyethylene water storage tanks As per IS 12701 : 1906 with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.(For 3000 litre capacity)

3

-

66368.16

... More
Supplying & fixing suction `Y'/ pot stainer with MS flange of suitable length fabricated from 16 gauge brass sheet with 3mm slots. 50 mm dia

2

-

7964

... More
Supplying , fixing, testing and commissioning of PVC welded rain water head / khurras dome type grating with puddle flange to fix head in RCC slab specially fabricated from minimum 4mm thick PVC sheet, including removable heavy duty PVC grating of 50 x 3 mm thick PVC flats (Round or Square) as per approved design The quoted rate shall include for necessary grouting the khurras base with approved sealant complete all as shown in the drawing and as specified. 150 x 150mm PVC Grating

10

-

7590

... More
Providing and fixing to wall, ceiling and floor high density polyethylene pipes 6.00 kgf /sqcm working pressure 75 mm outside diameter raising mains & exposed distribution pipes with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications.

269

-

119167

... More
Providing and fixing to wall, ceiling and floor high density polyethylene pipes 6.00 kgf /sqcm working pressure 110 mm outside diameter raising mains & exposed distribution pipes with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications.

348

-

223624.8

... More
Providing and fixing to wall, ceiling and floor high density polyethylene pipes 6.00 kgf /sqcm working pressure 140 mm outside diameter raising mains & exposed distribution pipes with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications.

170

-

136047.6

... More
Providing stone ware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary (Rate including cost of all materials, fixtures and lead). Size: 15 cm x 10 cm

12

-

3628.8

... More
Constructing brick masonry inspection chamber 600x600mm, and 450mm depth, ( clear inside dimension ) for pipeline with three or more inlets, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg ) R.C.C. top slab with cement concrete M 15 with 20mm and downsize granite metal , foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finished smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications.

24

-

220553.28

... More
Extra for item Depth beyond 450mm and brick masonry inspection chamber with table moulded non-modular bricks of class designation 50 in cement mortar 1:5, for every 150mm depth or part thereof including cost cost of materials, labour charges, curing complete as per specifications.

10

-

10065.6

... More
Earthwork excavation for foundation of building, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches where excavation width upto 0.6m, in ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excvation with lead upto 50m after breaking of clods complete as per specifications.

219.53

-

70890.63

... More
DOMESTIC WATER TRANSFAR PUMP Supplying, installing, testing and commissioning of submersible / Mono blockelectrical driven pump 1set . (1 working & standby) domestic water pumps for pumping domestic water from U.G. sump to over head water tank, with all necessary arrangements to operate on 3HP 50 HZ, 440V AC supply fitted on a common base frame accessories to lift the pump during maintenance , necessary power connections, the supplier shall include the control panel and wiring from TPN switch to control panel and wiring upto pumps, the control panel comprising of O/L relays, single phase preventor,separate overload trip and relayset, ON/OFF/TRIP indicating lamps,start/stop push buttons, With liquid level controlers, etc., complete as complete. Duty of the Pump 4 cum per hour at 20 TO 25 m head Make : Kirloskar/ suguna/texmo/CRI two set industrial type electronic automatic liquid level controllers, with stainless steel probes / sensors.

1

-

19807.2

... More
Providing and fixing in position 32 mm nominal bore gun metal non-return valve horizontal type of approved make including cost of all materials, labour and HOM of equipments with all leads complete as per specifications.

2

-

1598.4

... More
Providing and fixing in position 40 mm nominal bore gun metal non-return valve horizontal type of approved make including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Make: Zoloto

2

-

2045.52

... More
Construction of brick masonry catch basin chamber chambers of internal clear dimension as mentioned below by using first class table moulded modular bricks 230 mm thick wall in cement mortor joints in 1:4, over CC 1:4:8 bed 150 mm thick including Supplying precast RCC perforated top slab in 1:2:4 Mix (1 cement: 2 coarse coarse sand: 8 graded stone aggregate), with angle iron frame, inside plastering15mm thick with CM 1:3 (1 cement::3 fine sand) finished very smooth with floating coat of neat cement & making benching and channelling in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 gradedstone aggregate) neatly finished complete as per standard design and as per drawing and specifications.Inside size of 600 x 600mm & depth not exceeding 600 x 600mm including Supplying 450 x 450mm RCC cover with MS L angle frame.

20

-

138408

... More
Construction of percolation well / rain water harvest pit of 2 m dia and 3m deep with precast RCC rings, coveringthe top with RCC slab including supply and fixing 600 x 600 RCC MH cover CI / MS rungs etc. The quoted rate shall include earth work excavation, back filling, removing excess earth and making good the floor. The percolation well harvest pit shall be constructed as per the detail drawings and specification shall consists of: Allernate layers of brick bats, activated charcoal, gravel, pebbles and toped with fine sand for good infiltration. 3 Nos. bore holes of 160 mm dia from the bottom of percolation pit for a depth of 6m, drilled by using auger manually.Bore hole to be filled with medium sized pebbles to provide mechanical strength to the holes and enhance infiltration. Rate quoted shall be inclusive of earth work excavation, back filling, removing of excess earth as per the instructions of engineer - in charge.

2

-

55766

... More
Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. 32 mm dia

2

-

1392

... More
40 mm dia

2

-

1656

... More
50mm dia

2

-

2088

... More
65 mm dia

2

-

2796

... More
Refilling available earth around pipe lines, cables in layers not exceeding 20cms in depth, compacting each deposited layer by ramming after watering with lead upto 50m. and lift upto 1.5 m. including cost of all labour complete as per specifications.

833

-

108856.44

... More
Supplying, Intallation, testing and conmissioning of Solar Hot water Heater comprising of solar flat plat collector (FPC) of size 2120 x104 x100mm and stainless steel hot water storage tank with stainless steel Heat exchanges absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity with electrical back up arrangement excluding inlet and outlet pipes. SS model with 100mm thick of 48kg/m3 density rock wool insulation with 22WG Aluminium cladding.

6

-

388800



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.