Sri Jayadeva Institute Of Cardiovascular Sciences And Research Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Sri Jayadeva Institute Of Cardiovascular Sciences And Research Tender

Civil And Construction
Opening Date1 Oct 2024
Closing Date16 Oct 2024
Tender Amount₹ 3,52,34,782.34 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Civil04 - Aluminium Paint

20

236

4725

... More
Civil05 - Aluminium primer

20

189

3780

... More
Civil06 - Anchor Fastener - M10

100

13

1365

... More
Civil07 - Ball bearing for rolling shutters

150

294

44100

... More
Civil08 - Caustic soda

300

126

37800

... More
Civil09 - Chlorinated Polyvinyl - chloride (CPVC) pipe 20 mm nominal dia.

50

85

4252.5

... More
Civil10 - Chlorinated Polyvinyl - chloride (CPVC) pipe 25 mm nominal dia.

50

132

6615

... More
Civil11 - Chlorinated Polyvinyl - chloride (CPVC) pipe 32 mm nominal dia.

30

185

5575.5

... More
Civil12 - Chlorinated Polyvinyl - chloride (CPVC) pipe 40 mm nominal dia.

30

258

7749

... More
Civil13 - Chlorinated Polyvinyl - chloride (CPVC) pipe 50 mm nominal dia.

30

425

12757.5

... More
Civil14 - Chlorinated Polyvinyl - chloride (CPVC) pipe 65 mm nominal dia.

30

832

24979.5

... More
Civil15 - Chlorinated Polyvinyl - chloride (CPVC) pipe 100 mm nominal dia.

20

1540

30807

... More
Civil16 - Earth work excavation by manual means for drains, canals, waste weir draft, approach channels, key trench, foundation of Buildings & Bridges and such similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work Depth exceeding 1.5m, but not exceeding 3 m(PWD SR 2023-24 Pg No 29 Vol 1)

1000

254

254100

... More
Civil17 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates Centring & Suttering (8% of Concerte amount for foundation.)(PWD SR 2023-24 Pg No 60 Vol 1)

50

7050

352504

... More
Civil18 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates esign Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR 2023-24 Pg No 80 Vol 1)

10

7185

71851.5

... More
Civil19 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately)M30 Design Mix Using 20 mm and down size graded crushed coarse aggregates including formwork (PWD SR 2023-24 Pg No 80 Vol 1)

200

11036

2207206

... More
Civil20 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.

200

99

19950

... More
Civil21 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)

15

5693

85396.5

... More
Civil22 - Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.

15

12205

183078

... More
Civil23 - Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.

30

1113

33390

... More
Civil24 - Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (PWD SR 2023-24 Pg No 187 Vol 2)

22000

92

2032800

... More
Civil25 - Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge 0.63 mm thick with zinc coating not less than 275 g/ m² Extra for straight cutting in C.G.S. sheet roofing for making opening of area exceeding 40 sq. decimeter for sky light, chimney stacks etc.:.

80

922

73836

... More
Civil26 - Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge 0.63 mm thick with zinc coating not less than 275 g/ m² Extra for straight cutting in C.G.S. sheet roofing for making opening of area exceeding 40 sq. decimeter for sky light, chimney stacks etc.:. 0.63 mm thick

30

61

1858.5

... More
Civil27 - Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge 0.63 mm thick with zinc coating not less than 275 g/ m² Extra for straight cutting in C.G.S. sheet roofing for making opening of area exceeding 40 sq. decimeter for sky light, chimney stacks etc.:. Extra for circular cutting in C.G.S. sheet roofing for making opening of area exceeding 40 sq. decimeter: 0.63 mm thick

20

367

7350

... More
Civil28 - Providing & fixing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete as per design drawings. 0.63 mm thick with zinc coating not less than 275 g/m²

20

670

13419

... More
Civil29 - Providing & fixing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame. Flat surafce

100

1337

133770

... More
Civil30 - Providing & fixing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame.Extra for sunk or raised mouldings in the plaster of Paris (Gypsum anhydrous) ceiling.

30

476

14301

... More
Civil31 - Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 g/m2, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/m2 (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.

200

1795

359100

... More
Civil32 - Supply and Installation of Multicell Standing Seam polycarbonate panels having flux 7.0 as per EN 16153 & EN ISO 10077-2. For min joints, panel shall be 1000 - 1200 mm wide with standing seam on both sides. Panels shall have minimum six-seven layers with truss bridge design for higher flexibility and strength. The system shall be secured using suitable connectors with double tooth grip lock locking mechanism and fixed on purlin(to be paid separately) having a pull out load of min 7000N tested as per ISO 6892-1998 and IS 1608-2005. Panels must satisfy impact test as per IS 14443-97 shall show no sign of breakage which have been exposed to UV for 500 Hours (min) as per ASTM G 155. Panels shall have Yellowness Index of not more than 15 units as per ASTM D 1925 when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. Panel shall be closed at the end with additional Aluminium U profile as required. All aluminium should be factory finished / mill finished. Panel shall be fixed over MS structural steel / MS purlin (to be paid separately) conforming to the details in the specifications as per direction of Engineer in charge of work.

80

1777

142212

... More
Civil33 - 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process.

70

1270

88935

... More
Civil34 - Supply and Installation of Multicell Standing Seam polycarbonate panels having flux 7.0 as per EN 16153 & EN ISO 10077-2. For min joints, panel shall be 1000 - 1200 mm wide with standing seam on both sides. Panels shall have minimum six-seven layers with truss bridge design for higher flexibility and strength. The system shall be secured using suitable connectors with double tooth grip lock locking mechanism and fixed on purlin(to be paid separately) having a pull out load of min 7000N tested as per ISO 6892-1998 and IS 1608-2005. Panels must satisfy impact test as per IS 14443-97 shall show no sign of breakage which have been exposed to UV for 500 Hours (min) as per ASTM G 155. Panels shall have Yellowness Index of not more than 15 units as per ASTM D 1925 when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. Panel shall be closed at the end with additional Aluminium U profile as required. All aluminium should be factory finished / mill finished. Panel shall be fixed over MS structural steel / MS purlin (to be paid separately) conforming to the details in the specifications as per direction of Engineer in charge of work 12mm Thick Multicell Polycarbonate Panel having U value of 2.5 W/m2 K (max).

400

3469

1387680

... More
Civil35 - Providing & Fixing of Mineral Fibre Suspended Ceiling System in the module size of 600x600x19mm with Exposed grid for Hospitals, Shopping malls, Commercial establishments and office complexes. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 87%, Thermal Conductivity k = 0.052 - 0.057 w/m K, NRC -0.7,Colour White, Fire Performance UK A2 S1, dO, with Anti Microbial coating on the face of the tile, suitable for zone 4 area according to NF S 90-35:2003 with cleanroom class of ISO 5 (Class 100), Decontamination Class of CP1Oand Bacteriological Cleanliness Class B1 for specific strains and reduction in colony size. Washability properties of 500 wash cycles as per ASTM D-4828 and suitable for Green Building application with Recycled content of 37%. The tile shall be laid on 24mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15 kg/m2 & pull out strength of minimum 100 kg The T Sections should have a Galvanizing of 90 grams per m2 and need to be installed with suspension system of approved make.The tiles Shall be laid on 24mm Wide T-Sections Flanges colour white having rotary stitching on all T sections i.e. the Main runner with a web height of 38mm and 1200mm & 600mm Cross Tees with a web height of 32mm having thickness of 0.33mm and Wall angle of 24*24mm with 0.4 mm thickness , having load carrying capacity of 15 kg/m2. The T sections should have Galvanizing of 120 g/m2 and need to be installed with Suspension system.

250

2354

588525

... More
Civil36 - Providing & Fixing of Intergral Densified Micro Look edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System in Module Size of 600x600x15mm Suitable with Exposed GI Silhouette Profile Black Reveal T 15 Grid for Offices, Hospitals, Institutions, Airports, Banking Sector, Auditoriums, Community halls, laboratories, Factories and All buildings in high humidity or coastal Areas.The Lightweight Calcium Silicate Ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate Slurry/Mixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingrediants. The Tiles should have Humidity Resistance (RH) of 100%, Water Resistance, Non Combustible: as per BS:476 Part-4, Fire Performance: as per BS:476 Part-6 for Fire Propagation, as per BS:476 Part-7 for Surface Spread of Flame, As per UK standards Fire Performace A1-S1-d0, Thermal Conductivity K= 0.048 to 0.050 w/m K as per ECBC code 2007, NRC (Noise Reduction Coefficient ) 0.5 to 0.75 (Semi Perforated and Fully Perforated tiles) as per IS 8225:1987, Sound Attenuation (STA) 30-32dB,Thickness of tile should be 15mm thick with 450 kg/m3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350kg/m3 density in the center of the body,Light Reflectance greater than 85%, Weight of material is 5-5.5 kg/m2 and Suitable for Green Building application with InOrganic Recycled content of 46- 50% out of which 18- 20% should be FLYASH and meets the GRIHA & SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11&12, GRIHA V.3 criterion: 17&29 and SVAGRIHA criterion:12. The tiles Shall be laid on 15mm Wide Silhouette Profile Black reveal T-Sections Flanges colour white having rotary stitching double webbed on all T sections i.e. the Main runner with a web height of 42mm and 1200mm & 600mm Cross Tees with a web height of 42mm having thickness of 0.4mm and Wall angle of 15x20mm with 0.4 mm thickness , having load carrying capacity of 22 to 25 kg/m2. The T sections should have Galvanizing of 120 grams per m2 and need to be installed with Suspension system.

20

2289

45780

... More
Civil37 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

600

309

185850

... More
Civil38 - Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

500

297

148575

... More
Civil39 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.

600

105

63000

... More
Civil40 - Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 g/L, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.

2000

103

207900

... More
Civil41 - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.

4000

115

462000

... More
Civil42 - Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One coats on old work as per specifications and as per directions of Engineer in charge.

3000

86

258300

... More
Civil43 - Finishing walls with water proofing cement paint of required shade :Old work (one coats applied @ 2.20 kg/10 m²) over priming coat of primer applied @ 0.80 l/10 m² complete including cost of Priming coat including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

2500

91

228375

... More
Civil44 - Finishing walls with water proofing cement paint of required shade : Old work (one coats @ 2.20 kg/10 m²) complete. including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

400

58

23520

... More
Civil45 - Finishing walls with textured exterior paint of required shade :Old work (Two coats on existing cement paint surface applied @ 3.28 l/10 m² including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

200

226

45360

... More
Civil46 - Finishing walls with Acrylic Smooth exterior paint of required shade : Old work (Two coat applied @ 1.67 l/ 10 m²) on existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

4000

110

441000

... More
Civil47 - Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (One coat applied @ 0.90 l/10 m²) including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

400

72

28980

... More
Civil48 - Providing and fixing 10 mm thick acid and/or alkali resistant tiles of ap- proved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direc- tion of Engineer-in- Charge.

400

116

46620

... More
Civil49 - Providing and fixing 10 mm thick acid and/or alkali resistant tiles of ap- proved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direc- tion of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4coarse sand) with Acid and alkali resistant tile

400

1308

523320

... More
Civil50 - Providing and fixing 10 mm thick acid and/or alkali resistant tiles of ap- proved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direc- tion of Engineer-in- Charge. In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile

80

1323

105840

... More
Civil51 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.

50

1129

56490

... More
Civil52 - Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete.

50

1161

58065

... More
Civil53 - Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm.

50

1202

60112.5

... More
Civil54 - Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete Size of Tile 600x600 mm.

150

1233

185062.5

... More
Civil55 - Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm

300

1299

389970

... More
Civil56 - Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm

50

1392

69615

... More
Civil57 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.

100

1521

152145

... More
Civil58 - Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification.

50

978

48930

... More
Civil59 - Providing and laying 5mm thick Self levelling Epoxy Flooring for Residential, Commercial, Sports & Industrial purpose made of reputed brand applied at 1L/m2 on existing Concrete substrate of 25Mpa or more. The Concrete shall be free from any defects and cracks. The epoxy compound shall have low VOC (Based on USEPA Method 24 Section 11.2.2 & ASTM D2369-98) and is chemically resistant & antimicrobial. The surface of Concrete shall be cleaned thoroughly and free from laitance and applied with primer cured for 6-8 hours. The mix shall be mixed using Hand mixing rotary machine. The underlay shall be laid with 3mm thickness and overlay at 2mm. The entire operation shall be finished in line with epoxy coving and marked with 100mm thickness yellow marking lines complete as per the direction of Engineer in charge.

50

1518

75915

... More
Civil60 - Stone tile (polished) of 8mm thickness granite stone of any color and shade work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/m2 including pointing in white cement complete.

20

2725

54516

... More
Civil61 - Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti- tions by cutting a chase of appropriate width with chase cutter and embed- ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.

20

2928

58569

... More
Civil62 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete.

50

1161

58065

... More
Civil63 - Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete.

30

3526

105808.5

... More
Civil64 - Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification.

150

3787

568102.5

... More
Civil65 - Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.

5000

118

593250

... More
Civil66 - Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 5.5 mm thick glass panes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.

40

1320

52836

... More
Civil67 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, paneling and dash fasteners to be paid for separately):For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.

150

513

77017.5

... More
Civil68 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.

150

523

78592.5

... More
Civil69 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.:For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials,labour,usage charges of machinery complete as per specifications.

150

560

84105

... More
Civil70 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, paneling and dash fasteners to be paid for separately)For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.

200

599

119910

... More
Civil71 - Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer- in-charge: Pre-laminated particle board with decorative lamination on both sides including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

200

1032

206430

... More
Civil72 - Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m2) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge

100

1037

103740

... More
Civil73 - Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m2) including cost of materials, labour, usage charges of machinery complete as per specifications.

200

1299

259910

... More
Civil74 - Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications.

50

1370

68512.5

... More
Civil75 - Providing and fixing double action hydraulic floor spring of approved brand manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single pieceM.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge: With brass cover plate minimum 1.25 mm thickness including cost of materials, labour, usage charges of machinery complete as per specifications.

40

2944

117768

... More
Civil76 - Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer- in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately) including cost of materials, labour, usage charges of machinery complete as per specifications.

150

725

108832.5

... More
Civil77 - Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer-in-charge including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

500

66

33075

... More
Civil78 - Providing and fixing double glazed hermetically sealed glazing in alu- minium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

20

4562

91245

... More
Civil79 - Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

20

4958

99162

... More
Civil80 - Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540- F & ISO 11600 Upto 5 mm depth and 5 mm width including cost of materials, labour, usage charges of machinery complete as per specifications.

2800

120

338100

... More
Civil81 - Providing & fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TIO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made)

20

6557

131145

... More
Civil82 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm

50

737

36855

... More
Civil83 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 125mm

50

802

40110

... More
Civil84 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 150mm

50

847

42367.5

... More
Civil85 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness

20

3659

73185

... More
Civil86 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)35 mm thickness

30

4243

127291.5

... More
Civil87 - Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately).

15

4631

69473.25

... More
Civil88 - Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

10

5128

51281

... More
Civil89 - Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good theStainless Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with flush pipe and integrated type foot rests walls and floors wherever required:

10

9246

92463

... More
Civil90 - Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid

10

6275

62758.5

... More
Civil91 - Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern

10

4676

46767

... More
Civil92 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps

10

3236

32361

... More
Civil93 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap

10

2689

26890.5

... More
Civil94 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair15 mm C.P. brass pillar tap

10

3009

30093

... More
Civil95 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap

30

2462

73867.5

... More
Civil96 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Angle back wash basin size 600 x 480 mm with single 15mm C.P. brass pillar tap

5

2689

13445.25

... More
Civil97 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Angle back wash basin size 400 x 400 mm with single 15 mm C.P. brass pillar tap

5

2378

11891.25

... More
Civil98 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap

5

2203

11019.75

... More
Civil99 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:Stainless Steel AISI-304(18/8) Wash basin 530x345 mm with single 15 mm C.P. brass pillar tap

5

4341

21708.75

... More
Civil100 - Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer

5

4327

21635.25

... More
Civil101 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

15

1281

19215

... More
Civil102 - Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm

15

1068

16033.5

... More
Civil103 - Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Oval shape 450x350 mm (outer dimensions)

10

1119

11193

... More
Civil104 - Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.

100

773

77385

... More
Civil105 - Providing and laying of 1.5 mm thick SBS modified self adhesive single stick waterproofing membrane, with minimum elongation of 300% and puncture resistance of greater than200 N (as per ASTM E154), with an overlap of 100mm on the side and 100mm in vertical lapping over a coat bituminuos primer @ 0.25 l/m2, complete including surface preparation as per the methodology and site condition & placing the dimple board over the SBS membrane. The cost is inclusive of surface preparation, crack filling, repair of loose mortar etc. completely as per specification.

100

799

79905

... More
Civil106 - Providing and Applying Polyurethane hybrid liquid applied GRIHA certified Waterproofing coating with flutyne protection technology, single component, cold applied, water based acrylic and UV resistant water proofing treatment to the Existing Roof having Tile or any non-porous surface applied @ 1.5 l/m2 in 2 coats to achieve 1mm DFT, having tensile strength with 45 gsm glass fibre mesh 4N/mm2 confirming to ASTM D 412, Elongation at break greater than 300% and Crack bridging ability up to 3mm, SRI Index 106 as per ASTM E 1980-01, Water permeability @ 5 bar - Nil as per EN12390 - 8:2019, including surface preparation, priming the surface with single component high-performance waterborne tile primer which is suitable for non - porous surface at a rate of 0.083 L/m2 and spreading 45 gsm glass fibre mesh of 2.5 mm x 2.5 mm sandwiched between the first and second coat completely as per specification. The finished cost to include surface preparation, making coving at Junction, treatment of cracks completely as per specification

100

10009

1000950

... More
Civil107 - Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface like Roof, bathroom, toilet, balcony & utility area applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break greater than120% as per ASTM D 412, Tensile strength greater than1N/

50

551

27562.5

... More
Civil108 - Providing and Applying high build Acrylate Copolymers -based elastomeric waterproof coating for external wall, parapet & Chajja, which is single component, cold applied, acrylic emultion polymer. Apply coat 1st coat with 10% dilution water and 2nd coat without dilution @ 0.27L/m2 in 2 coats to achieve DFT of 110 microns, The material having followed technical properties: Attains hairline crack bridging up to 1 mm, Elongation of greater than120 % as per ASTMD 412; Tensile strength 1.50 Mpa per ASTM D 412, Pull off adhesion, 1.5Mpa as per ASTM D4541, including priming the surface with 1 coat diluted with water in the ratio 2:1 spreading @ 0.125 L/m2 as self-priming coat. The finished cost to include surface preparation, making coving at Junction, treatment of cracks completely as per specification.

150

268

40320

... More
Civil109 - Providing and Applying Acrylic Co Polymer single component specially designed waterproof protective coating that prevents damp patches on walls without any dilution at rate of 0.25kg/m2 in 2 coats to achieve total dry film thickness of 170 microns DFT. The material having followed technical properties: crack bridging ability up to 1mm as per EN 1062, Tensile strength greater than or equal to 2N/mm2 as per ASTM D 412, adhesion strength 1.5N/ mm2 as per ASTM D4541. The finished cost including surface preparation completely as per specification.

100

319

31920

... More
Civil110 - Providing and Applying 15 mm thick dimensionally stable fibrous reinforced cementitious structural grade dual shrinkage Polymer Repair Mortar on internal wall damp patches @ 29kg/m2. The material having Compressive strength of 38 MPa at 28 days as per EN 12190, Adhesive Bond Test, greater than1.5 Mpa as per EN 1542, followed by Water curing by sprinkling water for 3 times a day for 5- 7 days. Ensure that removing internal wall plaster up to the brick level. Extend up to minimum 2 feet in wide in excess to the damp patches. clean the effected surface followed by Item No. 4 should be applied across the entire surface and apply a coat of spatter dash bond coat over cured coating. The dashing shall consist of (1-part SBR : 1 Part cement: 2 part wash sand) mixed to thick slurry and kept well stirred prior to applying the Polymer Repair Mortar. The finished cost to include surface preparation completely as per specification.

20

1822

36456

... More
Civil111 - Providing and grouting with single component Polyurethane Foam injection grout at dripping leakage locations, grout mixed at ratio of 10:1 (10 parts of Resin: 1 part accelerator) at the rate of 0.40kg/nozzle which will foam after reaction with water/ moisture, cream time less than 20 seconds, rise time less than 30 seconds, foam expansion more than 30 times. It has a mixed viscosity of less than 350 CP as per ASTM D 2196. Allow the PU foam grout to cure

20

2088

41769

... More
Civil112 - Providing and laying with 1.0 mm thick FPO membrane to seal the expansion joint. The tape having mechanical properties like, Elongation greater than 500%, Tensile Strength greater than12N/mm2, Tear Strength greater than200N, Water tightness 400 kPa/72hrs confirming to DIN EN 1928-B. Ensure that apply Two part Epoxy Adhesive @ 1.4kg/m to get 1-2mm thick on the prepared surface before placing the tape and after placing seal with same epoxy adhesive which having Bond Strength with concrete 1.5N/mm2, Compressive Strength @ 7 days, greater than or equal 45N/mm2 as per BS 6319 Part 2, Tensile Strength @ 7 days, greater than or equal 18N/mm2 as per BS 6319 Part 7, Shear Strength @ 7 days, greater than or equal 8N/mm2 as per BS 6319 Part 4, Flexural Strength @ 7 days, N/mm2 as per BS 6319 Part 3. The finished cost including surface preparation, filling foam backer rod, applying masking tape on both sides of the joint & polysulphide sealant filling on gap completely as per specification.

30

2140

64228.5

... More
Civil113 - Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge.

20

1746

34923

... More
Civil114 - Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)

20

1080

21609

... More
Civil115 - Demolishing R.C.C. work manually/ by mechanical means including stack- ing of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.

20

2547

50946

... More
Civil116 - Demolishing brick work manually/ by mechanical means including stack- ing of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.

30

506

15183

... More
Civil117 - In cement mortar

30

1080

32413.5

... More
Civil118 - Dismantling tile work in floors and roofs laid in cement mortar includ- ing stacking material to the appropriate disposal area as per direction of Engineer-in-charge. For thickness of tiles 10 mm to 25 mm

400

50

20160

... More
Civil119 - Dismantling tile work in floors and roofs laid in cement mortar includ- ing stacking material to the appropriate disposal area as per direction of Engineer-in-charge. For thickness of tiles 10 mm to 25 mm GS Sheet

50

114

5722.5

... More
Civil120 - Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials to the appropriate disposal area as per direction of Engineer-in-charge.

30

576

17293.5

... More
Civil121 - Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge.

150

38

5827.5

... More
Civil122 - Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material to the appropriate disposal area as per direction of Engineer-in-charge.

250

37

9450

... More
Civil123 - Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials to the appropriate disposal area stacking serviceable and unserviceable material separately including cutting reinforcement bars.

15

2466

36996.75

... More
Civil124 - Repairs to existing aluminium partition including glass,board, lock, handle, beading etc cost of all material,labour, complete as per specifications.

600

2384

1430730

... More
Civil125 - Repair to existing ply wood ward-robes with 19mm plywood, beading,laminate and all necessary including cost of materials labour, lead, complete as per specifications.

500

827

413700

... More
Civil126 - Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/m²)

80

859

68796

... More
Civil127 - Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/m²)

60

1162

69741

... More
Civil128 - Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete

400

247

99120

... More
Civil129 - Renewing glass panes, with wooden fillets wherever necessary: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/m²)

20

1528

30576

... More
Civil130 - Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/m²)

20

1541

30828

... More
Civil131 - Renewing glass panes and refixing existing wooden fillets: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/m²)

60

964

57897

... More
Civil132 - Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/m²)

30

1267

38020.5

... More
Civil133 - Repair of pull and push type rolling shutters of made of 18 guage, 75mm wide cold rolled steel laths of convex corrugation, with side guides and bottom rail, with interlocking arrangements for steel laths by means of alternate clips, suspension shaft with High tension coil type springs two numbers, mounted on specially designed pipe shaft, with bracket plates, guide channels, ball bearing arrangements, for inside & outside locking with push & pull operations the which ever parts unserviceable should be replace (Springs, wheels, Shaft & replace the leafs which corroded) new one with all necessary including cost of materials, labour, complete as per specifications including cost of all materials, with all lead,

220

528

116193

... More
Civil134 - Removal of old broken glass panes ( any thickness of size, quality or description ) from wooden frames, glazed with putty or fixed with beads including cost of labour, complete as per specifications.

250

186

46725

... More
Civil135 - Removal of old broken glass panes ( any thickness of size, quality or description ) from metal frames, glazed with putty or fixed with beads including cost of labour, complete as per specifications.

200

264

52920

... More
Civil136 - Removing the glazed tiles in patches in area exceeding 10 tiles and not exceeding 5 sqm including removing old tiles preparing surfaces and laying or setting new or old tiles complete including cost of materials, ( excluding cost of tiles ) labour, complete as per specifications.

150

1198

179707.5

... More
Civil137 - Providing & fixing Roller Blinds of reputed make 38mm round Aluminium channel with blackout fabric, telting with chain (Ball) system with all necessary fittings and fixtures as per direction of Engineer in charge

100

1890

189000

... More
Civil138 - Providing & fixing Vertical Blinds of reputed make of shape 100mm regular fabric with powder coated aluminium channel, telting with PVC Chain system with all necessary fittings and fixtures as per direction of Engineer in charge

50

892

44625

... More
Civil139 - Providing & fixing 100% Polyester Curtains with specification of regular wash as per direction of Engineer in charge

200

1260

252000

... More
Electrical01 - KPWD SR 2023-24 P No 2, I No1.1.1, Open Conduit System Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thick

1000

79

79700

... More
Electrical02 - KPWD SR 2023-24 P No 2, I No1.1.2, Open Conduit System Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick

1000

93

93560

... More
Electrical03 - KPWD SR 2023-24 P No 2, I No1.1.3, Open Conduit Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.32 mm dia 2.5 mm thick

200

122

24486

... More
Electrical04 - KPWD SR 2023-24 P No 2, I No1.1.4, Open ConduitSupplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.40 mm dia 2.5 mm thick

150

172

25815

... More
Electrical05 - KPWD SR 2023-24 P No 2, I No,1.2.1, Concealed Conduit System Supplying heavy gauge PVC conduit pipe mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick

150

76

11434.5

... More
Electrical06 - KPWD SR 2023-24 P No 2, I No,1.2.2, Concealed Conduit System Supplying heavy gauge PVC conduit pipe mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick

100

90

9009

... More
Electrical07 - KPWD SR 2023-24 P No 2, I No,1.2.3, Concealed Conduit System Supplying heavy gauge PVC conduit pipe mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 32 mm dia 2.5 mm thick

150

118

17845.5

... More
Electrical08 - KPWD SR 2023-24 P No 2, I No,1.2.4 Concealed Conduit System Supplying heavy gauge PVC conduit pipe mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 40 mm dia 2.5 mm thick

100

169

16997

... More
Electrical09 - KPWD SR 2023-24 P No 2, I No,1.5.1 Supplying and fixing PVC/metal conduit Deep junction box19/20 mm deep Junction box

100

56

5660

... More
Electrical10 - KPWD SR 2023-24 P No 3, I No,1.5.2 Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box

100

64

6468

... More
Electrical11 - KPWD SR 2023-24 P No 3, I No,1.5.3 Supplying and fixing PVC/metal conduit Deep junction box 32 mm deep Junction box

50

70

3523

... More
Electrical12 - KPWD SR 2023-24 P No 3, I No,1.7.1 Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50 mm conduit in brick wall

100

33

3350

... More
Electrical13 - KPWD SR 2023-24 P No 3, I No,1.7.2 Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50 mm conduit CC floor

100

79

7970

... More
Electrical14 - KPWD SR 2023-24 P No 3, I No,1.8.1 Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required.20 mm

100

32

3234

... More
Electrical15 - KPWD SR 2023-24 P No 3, I No,1.8.2 Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required. 25 mm

100

40

4043

... More
Electrical16 - KPWD SR 2023-24 P No 3, I No,1.8.3 Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required. 30 mm

100

49

4967

... More
Electrical17 - KPWD SR 2023-24 P No 3, I No,1.8.4 Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required. 38 mm

100

71

7161

... More
Electrical18 - KPWD SR 2023-24 P No 3, I No,1.8.5 Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm as required.50 mm

100

49

4967

... More
Electrical19 - KPWD SR 2023-24 P No 3, I No,1.9.1Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 20 mm

100

21

2195

... More
Electrical20 - KPWD SR 2023-24 P No 3, I No,1.9.2Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely.25 mm

100

25

2541

... More
Electrical21 - KPWD SR 2023-24 P No 3, I No,1.9.3Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 32 mm

100

33

3350

... More
Electrical22 - KPWD SR 2023-24 P No 3, I No,1.9.4Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely.40 mm

100

41

4150

... More
Electrical23 - KPWD SR 2023-24 P No 3, I No,1.9.5 Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely.50 mm

50

54

2714.5

... More
Electrical24 - KPWD SR 2023-24 P No 3, I No,1.9.6 Supplying PVC flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely.63 mm

50

79

3985

... More
Electrical25 - KPWD SR 2023-24 P No 3, I No,1.10.1 Supplying Galvanized steel flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely.20 mm

50

61

3061

... More
Electrical26 - KPWD SR 2023-24 P No 3, I No,1.10.2 Supplying Galvanized steel flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely.25 mm

100

83

8316

... More
Electrical27 - KPWD SR 2023-24 P No 3, I No,1.10.3 Supplying Galvanized steel flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely.32 mm

50

94

4735.5

... More
Electrical28 - KPWD SR 2023-24 P No 3, I No,1.10.4 Supplying Galvanized steel flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 40 mm

50

103

5197.5

... More
Electrical29 - KPWD SR 2023-24 P No 3, I No,1.10.4 Supplying Galvanized steel flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 50 mm

50

143

7161

... More
Electrical30 - KPWD SR 2023-24 P No 3, I No,1.11 Supplying And Fixing inchesSinches Hook made out of 14 mm dia M.S. Rod.

50

60

3030

... More
Electrical31 - KPWD SR 2023-24 P No 4, I No,1.12 Supplying And Fixing M.S. Rafter Clamp Set made out of M.S. Flat & 14 mm M.S. rod.

50

184

9240

... More
Electrical32 - KPWD SR 2023-24 P No 4, I No,1.13 Supplying And Fixing Metal Fan Box with Round Hook.

50

135

6757

... More
Electrical33 - KPWD SR 2023-24 P No 5, I No,2.2.1 Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm Phase & Neutral & 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box

200

310

62140

... More
Electrical34 - KPWD SR 2023-24 P No 5, I No,2.2.2 Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm Phase & Neutral & 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box

200

437

87550

... More
Electrical35 - KPWD SR 2023-24 P No 5, I No,2.2.3 Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm Phase & Neutral & 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outle Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box

600

641

384618

... More
Electrical36 - KPWD SR 2023-24 P No 5, I No,2.3.1 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 1 mm2

500

21

10975

... More
Electrical37 - KPWD SR 2023-24 P No 5, I No,2.3.2 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 1.5 mm2

1000

30

30030

... More
Electrical38 - KPWD SR 2023-24 P No 5, I No,2.3.3 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 2.5 mm2

1000

48

48510

... More
Electrical39 - KPWD SR 2023-24 P No 5, I No,2.3.4 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 4 mm2

500

72

36385

... More
Electrical40 - KPWD SR 2023-24 P No 5, I No,2.3.5 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 6 mm2

500

106

53130

... More
Electrical41 - KPWD SR 2023-24 P No 6, I No,2.3.6 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 10 mm2

400

192

77156

... More
Electrical42 - KPWD SR 2023-24 P No 6, I No,2.3.7 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:2010 16 mm2

250

367

91822.5

... More
Electrical43 - KPWD SR 2023-24 P No 6, I No,2.5.8 Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and Virgin PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 3C x 2.5 mm2

200

130

26104

... More
Electrical44 - KPWD SR 2023-24 P No 6, I No,2.5.9 Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and Virgin PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 4C x 2.5 mm2

200

170

34188

... More
Electrical45 - KPWD SR 2023-24 P No 6, I No,2.5.15 Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and Virgin PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 3C x 4 mm2

200

198

39732

... More
Electrical46 - KPWD SR 2023-24 P No 7, I No,2.5.22 Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and Virgin PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 3C x 6 mm2

100

292

29222

... More
Electrical47 - KPWD SR 2023-24 P No 8, I No, 3.3.1 Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1-2 Way

100

118

11897

... More
Electrical48 - KPWD SR 2023-24 P No 8, I No,3.3.2 Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 Way

100

143

14322

... More
Electrical49 - KPWD SR 2023-24 P No 8, I No,3.3.3 Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 Way

100

158

15824

... More
Electrical50 - KPWD SR 2023-24 P No 8, I No,3.3.4 Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way

100

199

19982

... More
Electrical51 - KPWD SR 2023-24 P No 8, I No,3.3.5 Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 Way

50

252

12647.5

... More
Electrical52 - KPWD SR 2023-24 P No 8, I No,3.3.6 Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 10-12 Way

50

301

15073

... More
Electrical53 - KPWD SR 2023-24 P No 8, I No,3.3.7 Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 16 Way

50

339

16978.5

... More
Electrical54 - KPWD SR 2023-24 P No 8, I No,3.3.8 Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 18 Way

50

391

19577.5

... More
Electrical55 - KPWD SR 2023-24 P No 8, I No,3.4.1 Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2 Way

50

159

7969.5

... More
Electrical56 - KPWD SR 2023-24 P No 8, I No,3.4.2 Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3 Way

50

183

9182.5

... More
Electrical57 - KPWD SR 2023-24 P No 8, I No,3.4.3 Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way

50

204

10222

... More
Electrical58 - KPWD SR 2023-24 P No 8, I No,3.4.4 Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way

50

254

12705

... More
Electrical59 - KPWD SR 2023-24 P No 8, I No,3.4.5 Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way

50

301

15073

... More
Electrical60 - KPWD SR 2023-24 P No 8, I No,3.4.6 Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12 Way

30

368

11053.5

... More
Electrical61 - KPWD SR 2023-24 P No 8, I No,3.4.7 Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16 Way

30

419

12578.1

... More
Electrical62 - KPWD SR 2023-24 P No 8, I No,3.4.8 Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 18 Way

25

467

11694.5

... More
Electrical63 - KPWD SR 2023-24 P No 8, I No,3.5.1 Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module

50

158

7912

... More
Electrical64 - KPWD SR 2023-24 P No 8, I No,3.5.2 Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module

50

185

9284.5

... More
Electrical65 - KPWD SR 2023-24 P No 8, I No,3.5.3 Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module

50

202

10106.5

... More
Electrical66 - KPWD SR 2023-24 P No 8, I No,3.5.4 Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module

80

270

21621.6

... More
Electrical67 - KPWD SR 2023-24 P No 8, I No,3.5.5 Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module

50

328

16401

... More
Electrical68 - KPWD SR 2023-24 P No 8, I No,3.5.6 Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 10-12 Module

100

397

39732

... More
Electrical69 - KPWD SR 2023-24 P No 8, I No,3.5.7 Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 16 Module

50

458

22927

... More
Electrical70 - KPWD SR 2023-24 P No 9, I No,3.6.1 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch

200

117

23562

... More
Electrical71 - KPWD SR 2023-24 P No 9, I No,3.6.3 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Three Way socket

200

197

39502

... More
Electrical72 - KPWD SR 2023-24 P No 9, I No,3.6.4 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped Fan Regulator Two Module

100

412

41234

... More
Electrical73 - KPWD SR 2023-24 P No 9, I No,3.6.7 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16A One Way Switch

100

207

20790

... More
Electrical74 - KPWD SR 2023-24 P No 9, I No,3.6.8 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Bell Push

50

204

10222

... More
Electrical75 - KPWD SR 2023-24 P No 9, I No,3.6.9 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32A DP Switch

100

376

37653

... More
Electrical76 - KPWD SR 2023-24 P No 9, I No,3.6.10 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16A Universal Socket

100

272

27258

... More
Electrical77 - KPWD SR 2023-24 P No 9, I No,3.6.11 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 TV/Telephone Socket

50

180

9009

... More
Electrical78 - KPWD SR 2023-24 P No 9, I No,3.6.12 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 RJ45/I.O Outlet Cat-6

50

389

19462

... More
Electrical79 - KPWD SR 2023-24 P No 9, I No,3.13.1 Supplying and fixing of metal clad industrial plugs and sockets.2pole plus earth 250V PLUG 16A

25

447

11196.5

... More
Electrical80 - KPWD SR 2023-24 P No 9, I No,3.13.2 Supplying and fixing of metal clad industrial plugs and sockets.2pole plus earth 250V PLUG 32A

40

633

25321.2

... More
Electrical81 - KPWD SR 2023-24 P No 9, I No,3.13.3 Supplying and fixing of metal clad industrial plugs and sockets 3pole plus earth 440V PLUG 16A

40

522

20888.4

... More
Electrical82 - KPWD SR 2023-24 P No 9, I No,3.13.4 Supplying and fixing of metal clad industrial plugs and sockets 3pole plus earth 440V PLUG 32A

40

704

28175.6

... More
Electrical83 - KPWD SR 2023-24 P No 9, I No,3.13.5 Supplying and fixing of metal clad industrial plugs and sockets 2pole plus earth 250V SOCKET 16A

30

613

18398.1

... More
Electrical84 - KPWD SR 2023-24 P No 9, I No,3.13.6 Supplying and fixing of metal clad industrial plugs and sockets 2pole plus earth 250V SOCKET 32A

40

770

30817.2

... More
Electrical85 - KPWD SR 2023-24 P No 9, I No,3.13.7 Supplying and fixing of metal clad industrial plugs and sockets 3pole plus earth 440V SOCKET 16A

40

732

29280.8

... More
Electrical86 - KPWD SR 2023-24 P No 10. I No,3.13.8 Supplying and fixing of metal clad industrial plugs and sockets 3pole plus earth 440V SOCKET 32A

40

956

38245.2

... More
Electrical87 - KPWD SR 2023-24 P No 10. I No,3.14.1 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board .6A Three Pin Top

80

100

8039.2

... More
Electrical88 - KPWD SR 2023-24 P No 10. I No,3.14.7 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board . 6A Batten Holder

80

85

6837.6

... More
Electrical89 - KPWD SR 2023-24 P No 10. I No,3.14.12 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 16A Three Way 5 Pin Socket

100

132

13283

... More
Electrical90 - KPWD SR 2023-24 P No 10. I No,3.14.13 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 16A Three Pin Top

100

127

12705

... More
Electrical91 - KPWD SR 2023-24 P No 10. I No,3.14.15 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 16/6A combined plug and socket with control switch

100

251

25179

... More
Electrical92 - KPWD SR 2023-24 P No 10. I No,3.14.16 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board Electronic stepped regulator.

100

324

32456

... More
Electrical93 - KPWD SR 2023-24 P No 16. I No,5.15.1 Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . Icuequal to100% lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.THREE Pole 100 A 25 kA

15

7029

105439.95

... More
Electrical94 - KPWD SR 2023-24 P No 17. I No,5.15.2 Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . Icu=100% lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.THREE Pole 125 A 25 kA

10

9930

99306.9

... More
Electrical95 - KPWD SR 2023-24 P No 17. I No,5.15.3 Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . Icu=100% lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.THREE Pole 160 A 25 kA

5

12762

63810

... More
Electrical96 - KPWD SR 2023-24 P No 17. I No,5.15.5 Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . Icu=100% lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.THREE Pole 250 A 25 kA

5

12762

63813.75

... More
Electrical97 - KPWD SR 2023-24 P No 17. I No,5.15.5 Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . Icu=100% lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.THREE Pole 250 A 25 kA

5

19603

98019.1

... More
Electrical98 - KPWD SR 2023-24 P No 17. I No,5.15.9 Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . Icu=100% lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 100 A 25 kA

10

90802

908024.9

... More
Electrical99 - KPWD SR 2023-24 P No 17. I No,5.15.9 Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . Icu=100% lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 125 A 25 kA

5

11943

59719.3

... More
Electrical100 - KPWD SR 2023-24 P No 17. I No,5.15.13 Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . Icu equal to100% lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 250 A 25 kA

5

24706

123533.05

... More
Electrical101 - KPWD SR 2023-24 P No 17. I No,5.15.16 Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . Icu equal to100% lcs. In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 400 A 36 kA

2

32589

65178.96

... More
Electrical102 - KPWD SR 2023-24 P No 17. I No,5.17.1 Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane PUR gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2.4 Way

8

11930

95440

... More
Electrical103 - KPWD SR 2023-24 P No 17. I No,5.17.2 Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane PUR gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2.8 Way

6

14558

87352.68

... More
Electrical104 - KPWD SR 2023-24 P No 17. I No,5.17.3 Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane PUR gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12 Way

4

17936

71744

... More
Electrical105 - KPWD SR 2023-24 P No 17. I No,5.18.1 Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP

50

479

23950

... More
Electrical106 - KPWD SR 2023-24 P No 17. I No,5.18.4 Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP

50

853

42650

... More
Electrical107 - KPWD SR 2023-24 P No 17. I No,5.18.7 Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A TPN

50

1983

99150

... More
Electrical108 - KPWD SR 2023-24 P No 18. I No,5.18.9 Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN

50

3566

178300

... More
Electrical109 - KPWD SR 2023-24 P No 18. I No,5.19.1 Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. I - Single Door 4 Way SP & N

50

1433

71650

... More
Electrical110 - KPWD SR 2023-24 P No 18. I No,5.19.2 Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. I - Single Door 6 Way SP & N

20

1369

27380

... More
Electrical111 - KPWD SR 2023-24 P No 18. I No,5.19.3 Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. I - Single Door 8 Way SP & N

20

1723

34460

... More
Electrical112 - KPWD SR 2023-24 P No 18. I No,5.19.4 Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. I - Single Door 12 Way SP & N

15

2151

32265

... More
Electrical113 - KPWD SR 2023-24 P No 18. I No,5.19.5 Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. I - Single Door 16 Way SP & N

10

3386

33860

... More
Electrical114 - KPWD SR 2023-24 P No 18. I No,5.19.6 Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 4 Way SP & N

20

1760

35200

... More
Electrical115 - KPWD SR 2023-24 P No 18. I No,5.19.7 Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. I - Double Door 6 Way SP & N

20

2068

41360

... More
Electrical116 - KPWD SR 2023-24 P No 18. I No,5.19.8 Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 8 Way SP & N

20

2141

42820

... More
Electrical117 - KPWD SR 2023-24 P No 18. I No,5.19.9 Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 12 Way SP & N

20

2690

53800

... More
Electrical118 - KPWD SR 2023-24 P No 18. I No,5.19.11 Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. III - Double Door 4 Way TP & N

15

4663

69945

... More
Electrical119 - KPWD SR 2023-24 P No 18. I No,5.19.12 Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. III - Double Door 6 Way TP & N

20

5706

114120

... More
Electrical120 - KPWD SR 2023-24 P No 18. I No,5.19.13 Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. III - Double Door 8 Way TP & N

15

7035

105525

... More
Electrical121 - KPWD SR 2023-24 P No 18. I No,5.19.14 Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. III - Double Door 12 Way TP & N

10

10088

100880

... More
Electrical122 - KPWD SR 2023-24 P No 18. I No,5.20.1Supplying, fixing and wiring Residual current circuit breaker RCCB 240/450V upto 300mA sensitivity on existing wood/ panel board. 16A-25A 2 pole

10

4940

49400

... More
Electrical123 - KPWD SR 2023-24 P No 18. I No,5.20.2Supplying, fixing and wiring Residual current circuit breaker RCCB 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40A 2 pole

10

5265

52650

... More
Electrical124 - KPWD SR 2023-24 P No 18. I No,5.20.8Supplying, fixing and wiring Residual current circuit breaker RCCB 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40A 4 pole

10

5944

59440

... More
Electrical125 - KPWD SR 2023-24 P No 18. I No,5.20.10 Supplying, fixing and wiring Residual current circuit breaker RCCB 240/450V upto 300mA sensitivity on existing wood/ panel board. 63 A 4 pole

10

6404

64040

... More
Electrical126 - KPWD SR 2023-24 P No 18. I No,5.22 Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.

10

522

5220

... More
Electrical127 - KPWD SR 2023-24 P No 18. I No,5.23 Supplying, fixing and wiring 0 to 30V Direct Reading DC Voltmeter/Ammeter.

10

797

7970

... More
Electrical128 - KPWD SR 2023-24 P No 18. I No,5.24 Supplying, fixing and wiring 0 to 30A Direct Reading AC analog type Ammeter

10

537

5370

... More
Electrical129 - KPWD SR 2023-24 P No 19. I No,5.27 Supplying, fixing and wiring rotary selector switch suitable for Ammeter

10

231

2310

... More
Electrical130 - KPWD SR 2023-24 P No 19. I No,5.28 Supplying, fixing and wiring rotary selector switch suitable for Voltmeter

10

185

1850

... More
Electrical131 - KPWD SR 2023-24 P No 19. I No,5.33 Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy

10

10759

107590

... More
Electrical132 - KPWD SR 2023-24 P No 19. I No,5.34 Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.

10

649

6490

... More
Electrical133 - KPWD SR 2023-24 P No 19. I No,5.38 Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.

10

595

5950

... More
Electrical134 - KPWD SR 2023-24 P No 20. I No,5.40.1 Supplying A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100 A 4 x 30 x 6 mm Aluminium Strips

30

2847

85410

... More
Electrical135 - KPWD SR 2023-24 P No 20. I No,5.40.2 Supplying A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips

30

9367

281010

... More
Electrical136 - KPWD SR 2023-24 P No 20. I No,5.40.3 Supplying A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 400 A 4 x 50 x 10 mm Aluminium Strips

60

5134

308040

... More
Electrical137 - KPWD SR 2023-24 P No 20. I No,5.42 Fabricating supplying and mounting MS box made out SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG

50000

-

29000

... More
Electrical138 - KPWD SR 2023-24 P No 21. I No,5.45.1 Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB Without MCB. The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. SP & N 10 A

10

1091

10910

... More
Electrical139 - KPWD SR 2023-24 P No 21. I No,5.45.2 Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB Without MCB. The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. SP & N 20 A

10

1121

11210

... More
Electrical140 - KPWD SR 2023-24 P No 21. I No,5.45.3 Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB Without MCB. The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. TP & N 20 A

10

1548

15480

... More
Electrical141 - KPWD SR 2023-24 P No 21. I No,5.45.4 Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB Without MCB. The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. TP & N 30 A

10

1963

19630

... More
Electrical142 - KPWD SR 2023-24 P No 21. I No,5.47 Supplying and fixing Microprocessor based Electronic timer without contactor, Din Mounting using necessary bolts, nuts and washers etc.,. 3-120sec setting.

5

2673

13365

... More
Electrical143 - KPWD SR 2023-24 P No 30. I No,6.1 Supplying exhaust fan of 1440 RPM of 300 mm 12inches size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.

100

1723

172300

... More
Electrical144 - KPWD SR 2023-24 P No 30. I No,6.2 Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12inches Sweep 300 mm

100

3429

342900

... More
Electrical145 - KPWD SR 2023-24 P No 30. I No,6.2 Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.15inches Sweep 450 mm

100

5135

513500

... More
Electrical146 - KPWD SR 2023-24 P No 30. I No,6.3.1 Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48inches Sweep 1200 mm Regular model

100

3446

344600

... More
Electrical147 - KPWD SR 2023-24 P No 30. I No,6.3.2 Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.56inches Sweep 1400 mm Regular model

75

3500

262500

... More
Electrical148 - KPWD SR 2023-24 P No 30. I No,6.5.1Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply.300 mm Sweep

30

2878

86340

... More
Electrical149 - KPWD SR 2023-24 P No 30. I No,6.5.2Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply.400 mm Sweep

30

3709

111270

... More
Electrical150 - KPWD SR 2023-24 P No 34 INo,7.1.1 Supplying.litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.10 L

5

8736

43680

... More
Electrical151 - KPWD SR 2023-24 P No 34. INo,7.1.2 Supplying.litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.15 L

5

10123

50615

... More
Electrical152 - KPWD SR 2023-24 P No 34. INo,7.2.1 Supplying litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside Fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting 5 star fiber body 25 L

15

13778

206670

... More
Electrical153 - KPWD SR-2023-24,P no.36,I.No.8.1,Supplying and drawing UTP-CAT 6E LAN cable.

800

43

35112

... More
Electrical154 - KPWD SR-2023-24,P no.36,I.No.8.2.1,Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.1Pair

50

17

866.5

... More
Electrical155 - KPWD SR-2023-24,P no.36,I.No.8.2.2Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.2Pair

50

24

1213

... More
Electrical156 - KPWD SR-2023-24,P no.36,I.No.8.2.3Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.3Pair

50

32

1617

... More
Electrical157 - KPWD SR-2023-24,P no.36,I.No.8.2.4Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.4Pair

50

40

2021.5

... More
Electrical158 - KPWD SR-2023-24,P no.36,I.No.8.2.5Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.5Pair

50

53

2656.5

... More
Electrical159 - KPWD SR-2023-24,P no.36,I.No.8.2.6Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.10pair

50

93

4678

... More
Electrical160 - KPWD SR-2023-24,P no.36,I.No.8.2.7Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.20pair

50

173

8662.5

... More
Electrical161 - KPWD SR-2023-24,P no.36,I.No.8.2.8Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.50pair

50

469

23450

... More
Electrical162 - KPWD SR-2023-24,P no.36,I.No.8.3Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.

100

50

5082

... More
Electrical163 - KPWD SR-2023-24,P no.36,I.No.8.4.2Supplying & Fixing of switch mounting rack with power manager & Cable manager.6U with 450mm depth

20

8058

161160

... More
Electrical164 - KPWD SR-2023-24,P no.36,I.No.8.4.3Supplying & Fixing of switch mounting rack with power manager & Cable manager.9U with 450mm depth

20

9790

195800

... More
Electrical165 - KPWD SR-2023-24,P no.36,I.No.8.10.1 supplying &fixing of I/O socket with back box Single I/O

50

566

28300

... More
Electrical166 - KPWD SR-2023-24,P no.37,I.No.8.10.2supplying &fixing of I/O socket with back box Double I/O

50

635

31750

... More
Electrical167 - KPWD SR-2023-24,P no.37,I.No.8.11.1Supplying & Fixing of ms Cat 6 Patch Cable1 m

50

259

12950

... More
Electrical168 - KPWD SR-2023-24,P no.37,I.No.8.11.2Supplying & Fixing of ms Cat 6 Patch Cable2 m

50

297

14850

... More
Electrical169 - KPWD SR-2023-24,P no.37,I.No.8.11.2Supplying & Fixing of ms Cat 6 Patch Cable3 m

50

382

19100

... More
Electrical170 - KPWD SR-2023-24,P no.37,I.No.8.12.1Supplying & Fixing of Patch panel for LAN cabling48 Port 10/100 patch panel

3

16309

48927

... More
Electrical171 - KPWD SR-2023-24,P no.37,I.No.8.12.2Supplying & Fixing of Patch panel for LAN cabling24 Port 101100 patch panel

3

4735

14205

... More
Electrical172 - KPWD SR-2023-24,P no.37,I.No.8.12.3Supplying & Fixing of Patch panel for LAN cabling16 Port 10/100 patch panel

3

3523

10569

... More
Electrical173 - KPWD SR-2023-24,P no.37,I.No.8.12.4Supplying & Fixing of Patch panel for LAN cabling48 Port 10/100/1000 patch panel

3

27720

83160

... More
Electrical174 - KPWD SR-2023-24,P no.37,I.No.8.12.5Supplying & Fixing of Patch panel for LAN cabling24 Port 10/100/1000 patch panel

3

9124

27372

... More
Electrical175 - KPWD SR-2023-24,P no.37,I.No.8.12.6Supplying & Fixing of Patch panel for LAN cabling16 Port 10/100/1000 patch panel

2

8951

17902

... More
Electrical176 - KPWD SR-2023-24,P no.37,I.No.8.13.1Supplying & Fixing of Patch panel for LAN cablingSupplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination.10 Pair

3

399

1197

... More
Electrical177 - KPWD SR-2023-24,P no.37,I.No.8.13.2Supplying & Fixing of Patch panel for LAN cablingSupplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination.20 Pair

3

422

1266

... More
Electrical178 - KPWD SR-2023-24,P no.37,I.No.8.13.3Supplying & Fixing of Patch panel for LAN cablingSupplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination.30 Pair

3

656

1968

... More
Electrical179 - KPWD SR-2023-24,P no.37,I.No.8.13.4Supplying & Fixing of Patch panel for LAN cablingSupplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination.50 pair

3

728

2184

... More
Electrical180 - KPWD SR-2023-24,P no.43,I.No.11.3.1Supplying of .feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 2' - 9/10 W

100

638

63800

... More
Electrical181 - KPWD SR-2023-24,P no.43,I.No.11.3.2Supplying of .feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 W

100

799

79900

... More
Electrical182 - KPWD SR-2023-24,P no.43,I.No.11.3.3Supplying of .feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 36/40 W

100

1466

146600

... More
Electrical183 - KPWD SR-2023-24,P no.44,I.No.11.6.1Supplying of .feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.Supplying of recess mounting non integral type . LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly. with PF greater than 0.95, power loss should less than 5% of lamp Wage. short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 1'x1' 18W

150

3624

543600

... More
Electrial184 - KPWD SR-2023-24,P no.44,I.No.11.6.2Supplying of .feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.Supplying of recess mounting non integral type . LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should less than 5% of lamp Wage. short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 1'x1' 24W

100

4264

426400

... More
Electrical185 - KPWD SR-2023-24,P no.45,I.No.11.6.3Supplying of .feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.Supplying of recess mounting non integral type . LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 36 W

5

5258

26290

... More
Electrical186 - KPWD SR-2023-24,P no.45,I.No.11.6.4Supplying of .feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.Supplying of recess mounting non integral type . LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 36 WLED modular down light 2'x2' 40-42W

50

5614

280700

... More
Electrical187 - KPWD SR-2023-24,P no.45,I.No.11.6.5Supplying of .feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.Supplying of recess mounting non integral type . LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than 100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' 36 WLED modular down light 1'x4' 34-36W

20

6812

136240

... More
Electrical188 - KPWD SR-2023-24,P no.46,I.No.11.8.1Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiencygreater than1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Streetlight 25W

10

2801

28010

... More
Electrical189 - KPWD SR-2023-24,P no.46,I.No.11.8.3Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiencygreater than1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Streetlight 25WLED Streetlight 70W

30

6920

207600

... More
Electrical190 - KPWD SR-2023-24,P no.46,I.No.11.8.4Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiencygreater than1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Streetlight 25WLED Streetlight 90 W

5

10233

51165

... More
Electrical191 - KPWD SR-2023-24,P no.46,I.No.11.8.5Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiencygreater than1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Streetlight 25WLED Streetlight 120 W

30

11619

348570

... More
Electrical192 - KPWD SR-2023-24,P no.46,I.No.11.8.6Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiencygreater than1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Streetlight 25WLED Streetlight 150 W

15

16984

254760

... More
Electrical193 - KPWD SR-2023-24,P no.46,I.No.11.9.1Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiencygreater than 1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Floodlight 70W

30

7817

234510

... More
Electrical194 - KPWD SR-2023-24,P no.46,I.No.11.9.2Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiencygreater than 1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Floodlight 100W

25

10956

273900

... More
Electrical195 - KPWD SR-2023-24,P no.46,I.No.11.9.3Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiencygreater than 1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Floodlight 120W

30

12424

372720

... More
Electrical196 - KPWD SR-2023-24,P no.46,I.No.11.9.4Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiencygreater than 1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Floodlight 150W

20

14425

288500

... More
Electrical197 - KPWD SR-2023-24,P no.46,I.No.11.9.7Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiencygreater than 1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Floodlight 240W

10

25488

254880

... More
Electrical198 - KPWD SR-2023-24,P no.48,I.No.12.2.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Ding Dong Bell

25

284

7100

... More
Electrical199 - KPWD SR-2023-24,P no.48,I.No.12.2.2Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Musical

20

502

10040

... More
Electrical200 - KPWD SR-2023-24,P no.48,I.No.12.2.3Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Remote

20

1375

27500

... More
Electrical201 - KPWD SR-2023-24,P no.48,I.No.12.4.1Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Rewinding a mm ceiling fan/after using necessary gauge annealed and insulated copper wire with necessary insulating, separators vibration arresting shellac, etc including replacement of bearings if any transportation to and from the spot to workshop inclusive of releasing the refixing 900mm

10

639

6390

... More
Electrical202 - KPWD SR-2023-24,P no.48,I.No.12.4.2Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Rewinding a mm ceiling fan/after using necessary gauge annealed and insulated copper wire with necessary insulating, separators vibration arresting shellac, etc including replacement of bearings if any transportation to and from the spot to workshop inclusive of releasing the refixing.1050mm

10

808

8080

... More
Electrical203 - KPWD SR-2023-24,P no.48,I.No.12.4.3Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Rewinding a mm ceiling fan/after using necessary gauge annealed and insulated copper wire with necessary insulating, separators vibration arresting shellac, etc including replacement of bearings if any transportation to and from the spot to workshop inclusive of releasing the refixing.1200mm

75

884

66300

... More
Electrical204 - KPWD SR-2023-24,P no.48,I.No.12.4.4Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Rewinding a mm ceiling fan/after using necessary gauge annealed and insulated copper wire with necessary insulating, separators vibration arresting shellac, etc including replacement of bearings if any transportation to and from the spot to workshop inclusive of releasing the refixing.1400mm

75

921

69075

... More
Electrical205 - KPWD SR-2023-24,P no.48,I.No.12.5Releasing the existing fan dismantling testing painting after removing the existing painting by scraping and cleaning spray method not less than 2 coats of approved make enamel paint to a ceiling fan and wiring and fixing of the same.

100

392

39200

... More
Electrical206 - KPWD SR-2023-24,P no.48,I.No.12.6Supplying and replacing ceiling fan regulator 900mm to 1500mm.

100

441

44100

... More
Electrical207 - KPWD SR-2023-24,P no.48,I.No.12.7Releasing an unserviceable thermostat and providing in its place a new 20 A capacity 25 inch to 85 inch range thermostat.

50

381

19050

... More
Electrical208 - KPWD SR-2023-24,P no.49,I.No.12.13.1Supplying and fixing/replacement of heating element for Geyser/Boiler 2kW Capacity

15

1212

18180

... More
Electrical209 - KPWD SR-2023-24,P no.49,I.No.12.13.2Supplying and fixing/replacement of heating element for Geyser/Boiler 3kW Capacity

10

1292

12920

... More
Electrical210 - KPWD SR-2023-24,P no.49,I.No.12.16Supplying and fixing/replacement of heating element for Geyser/Boiler.Supplying and fixing 6A capacity 4 way universal shutter type spike buster suitable to operate on 230V 50Hz AC Supply.

10

839

8390

... More
Electrical211 - KPWD SR-2023-24,P no.55,I.No.12.60.2Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non- corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohmUsing 4ft. Copper bonded rod with backfill compoundUsing 6ft. Copper bonded rod with backfill compound

3

7196

21588

... More
Electrical212 - KPWD SR-2023-24,P no.55,I.No.12.60.5Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non- corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohmUsing 4ft. Copper bonded rod with backfill compoundUsing 6ft. SS rod with backfill compound

2

5229

10458

... More
Electrical213 - KPWD SR-2023-24,P no.55,I.No.12.60.6Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non- corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohmUsing 4ft. Copper bonded rod with backfill compoundUsing 10ft. SS rod with backfill compound

2

7195

14390

... More
Electrical214 - Single core x 50 Sqmm multi standard copper cable FLRS insulated flexible

20

1180

23600

... More
Electrical215 - Single core x 70 Sqmm multi standard copper cable FLRS insulated flexible

25

1627

40675

... More
Electrical216 - Single core x 95 Sqmm multi standard copper cable FLRS insulated flexible

25

2204

55100



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.