Rural Water Supply And Sanitation Department Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 5,79,520Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
RWSSD/2022-23/WS/WORK_INDENT56310Bid Award Id
ViewTender No
RWSSD/2022-23/WS/WORK_INDENT56310Tender Authority
Rural Water Supply And Sanitation Department ViewPurchaser Address
-Website
http://eproc.karnataka.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. - In all kinds of soils. Depth upto 1.50m (Manual Means) (Vol-I : Common SR 2021-2022 , Item No.1.6.1)
11717.2
-
4868730.94
Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 m3 capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work [Vol-3 : Common SR 2021-2022 , Item No.20.28]
63.86
-
462011.14
Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. PE100 (PN 6.0) [Vol-5: WS & UW SR 2021-22 Chapter: 11 Item No:11, K010 Pg.No:121] 63 mm Dia Pipe PE100 (PN 6.0)
79636
-
14610020.56
Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. PE100 (PN 6.0) [Vol-5: WS & UW SR 2021-22 Chapter: 11 Item No:11, K010 Pg.No:121] 75 mm Dia Pipe PE100 (PN 6.0)
2508
-
580602
Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. PE100 (PN 6.0) [Vol-5: WS & UW SR 2021-22 Chapter: 11 Item No:11, K010 Pg.No:121] 90 mm Dia Pipe PE100 (PN 6.0)
419
-
126282.41
Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. PE100 (PN 6.0) [Vol-5: WS & UW SR 2021-22 Chapter: 11 Item No:11, K010 Pg.No:121] 110 mm Dia Pipe PE100 (PN 6.0)
98
-
43234.66
Supplying and installation of Class SN8 Double Wall Corrugated HDPE pipe Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two “O” rings and a coupler of suitable size, including loading and unloading at both destination including jointing with all labour, all lead and lift including encasing the special around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done (the contractor shall have to make his own arrangement for procuring water for testing)(I.No.17 K140, Pg No.130,131, CSR 2021-22 Vol-V)63 MM ELECTRO FUSION COUPLER
796
-
125704.32
Supplying and installation of Class SN8 Double Wall Corrugated HDPE pipe Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two “O” rings and a coupler of suitable size, including loading and unloading at both destination including jointing with all labour, all lead and lift including encasing the special around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done (the contractor shall have to make his own arrangement for procuring water for testing)(I.No.17 K140, Pg No.130,131, CSR 2021-22 Vol-V)75 MM ELECTRO FUSION COUPLER
10
-
2004.8
Supplying and installation of Class SN8 Double Wall Corrugated HDPE pipe Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two “O” rings and a coupler of suitable size, including loading and unloading at both destination including jointing with all labour, all lead and lift including encasing the special around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done (the contractor shall have to make his own arrangement for procuring water for testing)(I.No.17 K140, Pg No.130,131, CSR 2021-22 Vol-V)90 MM ELECTRO FUSION COUPLER
2
-
517.44
Supplying and installation of Class SN8 Double Wall Corrugated HDPE pipe Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two “O” rings and a coupler of suitable size, including loading and unloading at both destination including jointing with all labour, all lead and lift including encasing the special around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done (the contractor shall have to make his own arrangement for procuring water for testing)(I.No.17 K140, Pg No.130,131, CSR 2021-22 Vol-V)63 MM ELECTRO FUSION TEE
265
-
73012.8
Supplying and installation of Class SN8 Double Wall Corrugated HDPE pipe Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two “O” rings and a coupler of suitable size, including loading and unloading at both destination including jointing with all labour, all lead and lift including encasing the special around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done (the contractor shall have to make his own arrangement for procuring water for testing)(I.No.17 K140, Pg No.130,131, CSR 2021-22 Vol-V)75 MM ELECTRO FUSION TEE
8
-
3207.68
Supplying and installation of Class SN8 Double Wall Corrugated HDPE pipe Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two “O” rings and a coupler of suitable size, including loading and unloading at both destination including jointing with all labour, all lead and lift including encasing the special around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done (the contractor shall have to make his own arrangement for procuring water for testing)(I.No.17 K140, Pg No.130,131, CSR 2021-22 Vol-V)90 MM ELECTRO FUSION TEE
1
-
591.36
Supplying and installation of Class SN8 Double Wall Corrugated HDPE pipe Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two “O” rings and a coupler of suitable size, including loading and unloading at both destination including jointing with all labour, all lead and lift including encasing the special around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done (the contractor shall have to make his own arrangement for procuring water for testing)(I.No.17 K140, Pg No.130,131, CSR 2021-22 Vol-V)63 MM ELECTRO FUSION ELBOW
228
-
63073.92
Supplying and installation of Class SN8 Double Wall Corrugated HDPE pipe Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two “O” rings and a coupler of suitable size, including loading and unloading at both destination including jointing with all labour, all lead and lift including encasing the special around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done (the contractor shall have to make his own arrangement for procuring water for testing)(I.No.17 K140, Pg No.130,131, CSR 2021-22 Vol-V)75 MM ELECTRO FUSION ELBOW
7
-
2257.92
Supplying and installation of Class SN8 Double Wall Corrugated HDPE pipe Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two “O” rings and a coupler of suitable size, including loading and unloading at both destination including jointing with all labour, all lead and lift including encasing the special around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done (the contractor shall have to make his own arrangement for procuring water for testing)(I.No.17 K140, Pg No.130,131, CSR 2021-22 Vol-V)90 MM ELECTRO FUSION ELBOW
1
-
507.36
Supplying and installation of Class SN8 Double Wall Corrugated HDPE pipe Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two “O” rings and a coupler of suitable size, including loading and unloading at both destination including jointing with all labour, all lead and lift including encasing the special around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done (the contractor shall have to make his own arrangement for procuring water for testing)(I.No.17 K140, Pg No.130,131, CSR 2021-22 Vol-V)75X63 MM ELECTRO FUSION REDUCER
6
-
1888.32
Supplying and installation of Class SN8 Double Wall Corrugated HDPE pipe Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two “O” rings and a coupler of suitable size, including loading and unloading at both destination including jointing with all labour, all lead and lift including encasing the special around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done (the contractor shall have to make his own arrangement for procuring water for testing)(I.No.17 K140, Pg No.130,131, CSR 2021-22 Vol-V)90X63 MM ELECTRO FUSION REDUCER
1
-
495.04
Supplying and installation of Class SN8 Double Wall Corrugated HDPE pipe Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two “O” rings and a coupler of suitable size, including loading and unloading at both destination including jointing with all labour, all lead and lift including encasing the special around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done (the contractor shall have to make his own arrangement for procuring water for testing)(I.No.17 K140, Pg No.130,131, CSR 2021-22 Vol-V)3 “M.S. FLANGE
98
-
21952
Supplying and installation of Class SN8 Double Wall Corrugated HDPE pipe Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two “O” rings and a coupler of suitable size, including loading and unloading at both destination including jointing with all labour, all lead and lift including encasing the special around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done (the contractor shall have to make his own arrangement for procuring water for testing)(I.No.17 K140, Pg No.130,131, CSR 2021-22 Vol-V)63 MM COMPRESSION MTA
80
-
17920
Supplying and installation of Class SN8 Double Wall Corrugated HDPE pipe Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two “O” rings and a coupler of suitable size, including loading and unloading at both destination including jointing with all labour, all lead and lift including encasing the special around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done (the contractor shall have to make his own arrangement for procuring water for testing)(I.No.17 K140, Pg No.130,131, CSR 2021-22 Vol-V)75 MM COMPRESSION MTA
3
-
1212.96
Supplying and installation of Class SN8 Double Wall Corrugated HDPE pipe Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and lowering into trenches, laying true to line and level and perfect linking at joints with the help of two “O” rings and a coupler of suitable size, including loading and unloading at both destination including jointing with all labour, all lead and lift including encasing the special around to a depth of not less than 15 cm with screened soft soil available from the excavated soil. The testing commissioning including necessary hydraulic test to the required pressure as per ISS shall be done (the contractor shall have to make his own arrangement for procuring water for testing)(I.No.17 K140, Pg No.130,131, CSR 2021-22 Vol-V)90 MM COMPRESSION MTA
1
-
449.12
Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Medium Duty GI pipe: [Vol-5: WS & UW SR 2021-22 Chapter: 13 Item No:2, N010 Pg.No:142] 80 mm Dia GI Pipe - Class(B)
960
-
907987.2
Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Medium Duty GI pipe: [Vol-5: WS & UW SR 2021-22 Chapter: 13 Item No:2, N010 Pg.No:142] 100 mm Dia GI Pipe - Class(B)
50
-
64476
Providing wrought mild steel (galvanized) GI collar confirming to IS 1239-II, 1991 with latest amendments if any. [Vol-5: WS & UW SR 2021-22 Chapter: 13 Item No:6, N090 Pg.No:144] 80 mm dia GI collar
160
-
61824
Providing wrought mild steel (galvanized) GI collar confirming to IS 1239-II, 1991 with latest amendments if any. [Vol-5: WS & UW SR 2021-22 Chapter: 13 Item No:6, N090 Pg.No:144] 100 mm dia GI collar
8
-
3709.44
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. [Vol-I : Common SR 2021-2022 , Item No.1.10]
18133.76
-
2477796.97
Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) For PN-10: [Vol-5: WS & UW SR 2021-22 Chapter: 3 Item No: 25, B073 Pg.No:71] Size 80mm
38
-
341033.28
Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS-1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.) For PN-10: [Vol-5: WS & UW SR 2021-22 Chapter: 3 Item No: 25, B073 Pg.No:71] Size 100mm
5
-
49604.8
Supplying and fixing kinetic AIR VALVE for automatic discharge of accumulate air during working condition, conforming to IS 14845 / EN 1074-4. Body and bonnet of DI conforming to IS-1865 of grade GGG-40/50, seals are made of approved EPDM, SS 304 float, guide and internals. Flange drilling according to IS-1538 with appurtenances. complete. Body and bonnet shall be coated with electrostatically applied epoxy powder coating with a coating thickness of 250 micron both inside and outside. [Vol-5: WS & UW SR 2021-22 Chapter: 3 Item No: 35, B083 Pg.No:75]
6
-
144063.36
Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m (I.No.1.4.1, Pg No.5, Vol-I CSR 2022) VPC
12.38
-
2579
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) - Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates [Vol-I : Common SR 2021-2022 , Item No.2.1.4]
1.15
-
7746.55
Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Vol-I : Common SR 2021-2022 , Item No.2.2.1]
5.9
-
41234.92
Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) [Vol-2 : Buildings SR 2021-2022 , Item No.11.32 Pg.No: 84]
400
-
41216
Supply and fixing of Cast steel ASTM A 216 Gr.WCB double flanged Dual plate check valve Conforming to API 594 with latest amendments Shaft material shall be SS420/431 and spring shall be spring steel superior grade quality as detailed below of following diameters and types and conveying to work site, loading, unloading, stacking with appurtenances., complete with all lead and lift. The rates are inclusive of cost of Galvanised Bolts and Nuts: For Class 150 [Vol-5: WS & UW SR 2021-22 Chapter: 3 Item No: 28, B076 Pg.No:72]
5
-
26264
Supply and fixing of Horizontal Mechanical Woltman type hemetically sealed water meters with copper Glass register with IP 68 protection. The meter shall be removable mechanism type manufactured as ISO 4064-1: 1993 with MID certification. The meters shall be capable of transmitting consumption data on daily basis to central server through GSM/GPRS. The meter interface unit shall be fitted to the meter without wire. The consumption data shall be collected , stored and analysed by data logger. The data logger should provide data like flow rate, total flow, consumption analyses, reverse flow, meter tampering, daily flow distribution, leakage detection. The data logger shall also send alams on blocked meter, flow rate above limit, pressure below or above limits. [Vol-5: WS & UW SR 2021-22 Chapter: 3 Item No: 9, R090 Pg.No:180]
5
-
390846.4
Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m [Vol-I : Common SR 2021-2022 , Item No.1.4.1]
99.22
-
20669.51
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) - Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates [Vol-I : Common SR 2021-2022 , Item No.2.1.4]
11.27
-
75916.19
Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Vol-I : Common SR 2021-2022 , Item No.2.2.1]
47.04
-
328761.15
Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) [Vol-2 : Buildings SR 2021-2022 , Item No.11.32 Pg.No: 84]
3920
-
403916.8
Providing house connection with excavation in all types of soils cutting with machine cutter without damaging the other utilities and supplying and laying of MDPE pipe (PE80) -PN 12.5 manufactured in accordance with ISO 4427 - 1996 with minimum required strength of 8 Mpa, hydraulic design stress of 6.3 Mpa and with minimum wall thickness of 2.3mm /GI pipe by making the bore of 15mm dia. size on the distribution mains using drilling bits or machines only and laying the pipe line at a depth not less than 0.45 mtrs. from the road surface, including providing 40mm dia. “A” class GI pipe as casing over the MDPE pipe from the bore point and upto the entrance of the premises and removing the stone slab covering of the drain and dismantling the size stone masonry wherever necessary and making bore in the wall of the premises. On entering the premises, connection should be continued with 20mm GI pipe by making “U” shape for the meter point below the ground level by making pit with sufficient space for the easy installation and removal of the water meter and providing vertical stand pipes on both sides of the meter. The connection should be secured firmly on thedistribution main pipe with SS / Brass ferrule of size 1/2” x 3/4” and fixing the union joint and gate valve / stop cock before the meter point and a reflex valve / non-return valve should be fixed on the connection after the meter point. (All these fixtures should be of standard quality conforming to IS).The compression fittings for MDPE pipes conforming to ISO 14236 and its latest versions. If the connection is of HDPE pipe the work include electric fusion tapping T or saddles,PE 100 black color pipie of PN 16 /SDR 11 or Higher grade conforming to standards with brass cutter,flow regurator,water tight cap with O’ring ,long spigot for making bore/tapping suitable to HDPE pipe by Electro fusion welding as per BS EN 12201-3 & EN 1555-3 standards. The Product should be tested to comply with BS 6920 for drinking water service in WRC - NSF, UK and DVGW certificate, Gemany. The Saddle should be manufactured Virgin Compounded PE 100 material.Tapping Tee or Saddles with coupler and compression fittings with cost of GI pipes, all specials such as GI tee, GI elbow, GI coupler, stopper with appurtenances, and brass or SS tap The excavated trench should be refilled with soft selected earth and the dismantled masonry of the drain should be re-constructed with available size stones in CM 1:8 and providing coping in CC 1:3:6 wherever required and the stone slab covering should be refixed in position with pointing in CM 1:3 and also the bored wall of the premises should be re-done to the original position and the rates are inclusive of the cost of all the materials, cement, sand water etc., required for these works. The road suface should be compacted well and brought to the original condition and the excess earth or debris should be disposed off to a distance with an initial lead of 10 Kms. etc. complete for The excavated trench should be refilled with soft selected earth and the dismantled masonry of the drain should be re-constructed with available size stones in CM 1:8 and providing coping in CC 1:3:6 wherever required and the stone slab covering should be refixed in position with pointing in CM 1:3 and also the bored wall of the premises should be re-done to the original position and the rates are inclusive of the cost of all the materials, cement, sand water etc., required for these works. The road suface should be compacted well and brought to the original condition and the excess earth or debris should be disposed off to a distance with an initial lead of 10 Kms. etc. complete for following diameters: (for minimum length of 2m) [Vol-5: WS & UW SR 2021-22 Chapter No.3 Item No: 23.1, B070A P no 71]
744
-
4785527.04
Supplying and fixing Multijet class B inferential type, AMR compatible water meters with IP 68 protection totalizer confoming to IS 779 with its latest amendments of following size to service connections including conveying and fixing of necessary G.I. specials with appurtenances. complete, with all lead and lift. [Vol-5: WS & UW SR 2021-22 Chapter No.3 Item No: 54.1, B118A P no 79]
744
-
1374078.72
Supply and fixing of HDPE water meter box with locking arrangement to protect the water meter of Class ‘B’ Multijet type of size 15 to 32 mm including HDPE box with base dia 300mm x lid dia 200mm x height 250mm with openable lid and the cover is buried below GL with lid flush with GL including earth work excavation for 600mm x 600mm and base sand filling for 100mm thick over which the cover is placed and enclosed by PCC 1:2:4 using 12-20mm BG jelly for an height of 150mm and refilling with excavated earth for balance 100mm height, disposal of excess earth with all lead and lifts with appurtenances complete as per drawing enclosed. [Vol-5: WS & UW SR 2021-22 Chapter No.11 Item No: 23, K200A P no 133]
744
-
424139.52
Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint omplete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, xcavation, refilling, transportation, and labour etc complete. Spec. No. As irected by Engineer in Charge & MoRTH specification 804[Vol-3: 21-C SR 2021-22 Chapter No.11 MORTH 804, P no 151]
1
-
10080
Supply and fixing of RCC demarcation stones of 30cms x 15cms and 90 cms using 1:2:4 CC and 6mm dia rods for verticals and stirrups and rendered smooth, including engraving letters "KWB and ARROW" 6mm deep on the top including fixing demaracation stones 45cms below ground level and cc 1:3:6, 15cms height with 8cms offset around the stone and curing for 10days including earthwork in all types of soils with all lead and lift (STAND POST) KUWS&DB, Blore SR 2018-19 pg. No. 24 item No. 24
744
-
366643.2
Supplying at site pot rest slab of 0.45mx0.30mx0.20m in CC. 1:2:4 proportion with granite metal 20 mm and down size including plank centering and fom work, machine mixing, tamping including plastering 20 mm thick in C.M. 1:4 proportion with all lead as per specification with appurtenances., complete 2021-22 Vol-5 pg No. 80 item No. 59
744
-
325812.48
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge CSR 2021-22 vol-2 page No. 48 frem No. 8.39
703.08
-
74807.71
Painting New Letter and Figures of any Shade with synthetic enamel paint black or any other approved colour to give an even shade complete as per specifications. (“i) Hindi/Kannada (Matras commas and the like not to be measured and paid for half letter shall be counted as half) “ MORTH Specification No. 803 [RWS SoR 2021-22, Item No.8.3, Page No.53,vol-3]
74400
-
99696
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements