Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Rural Drinking Water And Sanitation Department Tender

Civil And Construction
Water Storage And Supply
Opening Date31 Aug 2024
Closing Date9 Sep 2024
Tender Amount₹ 1,90,46,289.68 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. In Ordinary Soil.

175.92

371

65266.32

... More
code05 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. In Hard Soil.

117.28

371

43510.88

... More
code06 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

234.5

194

45493

... More
code07 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 75mm dia.

3257

213

693936.42

... More
code08 - Supply and delivery of 75 mm Electrofusion Coupler. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

34

153

5202

... More
code09 - Supply and delivery of 75mm Electrofusion elbow. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

17

246

4182

... More
code10 - Supply and delivery of 3 inch flange. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

10

200

2000

... More
code11 - Supply and delivery at site 80 mm dia GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

4

1902

7608

... More
code12 - Supplying and fixing kinetic 80 mm dia AIR VALVE PN 16.0 for automatic discharge of accumulate air during working condition, conforming to IS 14845 / EN 1074-4. Body and bonnet of DI conforming to IS-1865 of grade GGG-40/50, seals are made of approved EPDM, SS 304 float, guide and internals. Flange drilling according to IS-1538 with appurtenances. complete. Body and bonnet shall be coated with electrostatically applied epoxy powder coating with a coating thickness of 250 micron both inside and outside. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

1

2700

2700

... More
code13 - Supply and fixing of fixed height surface box H-4057 MD-KU with PP 40% GF Lid, Housing of PA+, Locking clip of PP with Notched bolt M 12 x 130 hexagon head A2-70 for service connection valves, design derived from DIN 4057, should be supplied with Support tile I (FSL, FSS, SI). Should be able to receive class AA traffic loads. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

5

2731

13655

... More
code14 - Providing, Laying and Fixing 100 mm dia GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing). including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. For Heavy Duty GI pipe.

20

1305

26111.2

... More
code15 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

88

122

10736

... More
code16 - Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

18

2288

41184

... More
code17 - Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 m3 capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

37

6152

227624

... More
code18 - Providing two coats of water proof cement painting with approved colour and shade over one coat of primer including scrapping the surface with wire brushes etc. before removal of scaffolding for new RCC over head tanks and cleaning of paint stains wherever necessary with all lead and lifts etc. complete for. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

673.114

153

102986.442

... More
code19 - Providing and fixing M.S. ladder between landing 45 cms. wide using angle iron of following size and 20 mm M.S. bars at 25cms. centre to centre with necessary supports of same angle iron as directed including hand railing on both sides with 25mm dia G.I. pipes with angle iron props at 2 mtrs, interval and 0.5 mtr, height including fixing in ground with C.C. 1:2:4 and two coats of nonpoisonous anticorrosive bituminous paint with alllead and lift etc., complete. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 65x65x8mm angle iron frame.

30

4323

129690

... More
code20 - Supplying and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of ductile iron (DI) conforming to IS 1865 and of grade GGG 40/50, shaft of stainless steel, wedge fully rubber lined with EDPM seals of NBR and the valves should be vacum tight and 100% leak proof with face to face dimensions as per IS 14846-2000 only. The stem sealing should be with toroidal sealing rings (minimum 2 “ O “ rings). Body and bonut should be coated with Electrostatically applied Epoxy Powder Coating with minimum coating thickness of 250 micron both inside and outside. The rate is inclusive of cost of valves, T.P set, galvanized bolts & nuts and rubber insertions etc. but excluding earth work. (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.). including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. For PN-10.

4

2900

11600

... More
code21 - Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

2

2111

4222

... More
code22 - KSRRB M800-10. Painting new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade complete as per specifications (ii) English and Roman-Hyphen and the like not to be measured and paid for "MORTH Specification No 801. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

200

1

240

... More
code23 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ). including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 0-50 mts.

100

347

34700

... More
code24 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ). including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 50-100 mts.

100

442

44200

... More
code25 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ). including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 100-150mts.

100

456

45600

... More
code26 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ). including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 150-200mts.

100

536

53600

... More
code27 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ). including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 200-250mts.

100

634

63400

... More
code28 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ). including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 250-300mts

100

700

70000

... More
code29 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ). including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 300-350mts.

100

825

82500

... More
code30 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ). including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 350-400mts.

100

900

90000

... More
code31 - Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ). including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 400-450mts.

100

1129

112900

... More
code32 - Supply of ISI mark 175mm nominal bore, plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

120

1933

231960

... More
code33 - Providing and laying at site of work MS casing caps as per IS 1239 (partII) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

2

164

328

... More
code34 - Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

2

150

300

... More
code35 - Supply and delivery at site brand new submersible Pump set sustainble for 150mm dia and having declared duty conditions as detailed below and satisfying performance and charectoristic for pump should confirm to IS 8034-1976 (With all its latest amendments and should bear the IS certification mark IS 8034-1976. The Pump set should consists of bronze impeller. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. Submersible Pump 25HP/18.5 kW 50M Staging.

2

125677

251354

... More
code36 - Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 1 x 3 x 6 sqm.

2000

210

420000

... More
code37 - Supply and delivery at site of brand new best make pressure gauge bourdon type as per IS 778/1984 with ISI Mark and as per its latest amendments. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 63mm Dia.

2

450

900

... More
code38 - Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 50mm dia.

2

1250

2500

... More
code39 - Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendment. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as p.er directions of Engineer incharge of work. 50 mm dia.

2

1275

2550

... More
code40 - Supply, installing, testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online 2) S-D- Star Delta Starter Upto 30 HP. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

2

30000

60000

... More
code41 - Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

4

550

2200

... More
code42 - Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

2

1250

2500

... More
code43 - Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover). including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 50 mm dia.

150

3050

457500

... More
code44 - Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work..

2

6150

12300

... More
code45 - Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

2

1250

2500

... More
code46 - Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554/ 1988 with latest amendments from KPTCL pole to meter board unit, with all necessary materials ,tools and equipments,as per specificationswith testing of as per instructions of engineer incharge of work. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 3.5 x 10 sqmm.

60

195

11700

... More
code47 - Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

40

135

5400

... More
code48 - Providing main connection from pole PVC insulated sheathed steel wire cable in GI pipe as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

20

80

1600

... More
code49 - Providing, Supplying and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 3.5x10 Sqmm.

2

650

1300

... More
code50 - Energy meter box supply and installation/fixing/provision of out door type thermoplastic modular panel enclosure with tranparent poly corbonate Lid, shock proof. IP65 (weather proof, rust proof, dust proof, corrosion proof having internally embeded gaset on both lid and palp suitable to fix single phase/ three phase energy meter in suitable base plate and having a provision for fuse/MCB along with complete tamper proof sealing fecility. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. d) 600x600x170mm Energy meter box.

2

12081

24162

... More
code51 - Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

2

3750

7500

... More
code52 - Chlorinator 80gms/Batch Production capacity : 25 gms/hr Total time per Batch : 8Hrs. Total volume of chlorine generation : 200gms/batch. Salt Required per hr. : 800gms/batch. Electrical power required : 230V, 1phase AC 50Hz. DC power supply unit with Input 230 V AC :1 NO FRP Brain water tank :35litrs PP/PVC Chlorine storage tank :35 Liters Dosing pump Type of Dosing : Automatic Proportionate Dosing Dosing flow rate :1to 30 lph Min actuating pressure :0.3kg/cm² Max working pressure :5kg/ cm² Inle/Outlet connections :¾” B.S.P Max Temoerature :50ºC Dosing externally adjustable :0.5-2% Chlorine test kit : 1 set. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

3

71500

214500

... More
code53 - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

2.31

73

168.63

... More
code54 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, plywood / steel formwork, cost of all materials of quality, labour, Usage charges of machineries, curing and all the other appurtenances required to complete the work as per technical specifications. ( The cost of steel reinforcement shall be paid separately). including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. PCC 1:4:8 using 40 mm aggregate.

1.17

5203

6087.861

... More
code55 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

6.364

6690

42575.16

... More
code56 - Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

127.29

198

25203.42

... More
code57 - Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

6

3660

21960

... More
code58 - Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

25.23

795

20057.85

... More
code59 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates.

1.2

5728

6873.6

... More
code60 - Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :One coat with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

127.29

61

7764.69

... More
code61 - Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m. including cost of labour, tools & other appurtenaces required to complete the work. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

13.62

186

2533.32

... More
code62 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates.

1.47

5554

8164.38

... More
code63 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, plywood / steel formwork, cost of all materials of quality, labour, Usage charges of machineries, curing and all the other appurtenances required to complete the work as per technical specifications. ( The cost of steel reinforcement shall be paid separately). including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

3.96

6279

24868.4832

... More
code64 - Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and / or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) including for OHT & reservoir, cost of materials, labour, HOM of machinery complete as per specifications. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. TMT bars Fe 550.

316.8

96

30412.8

... More
code65 - Supply and fixing of Horizontal Mechanical Woltman type hemetically sealed water meters with copper Glass register with IP 68 protection. The meter shall be removable mechanism type manufactured as ISO 4064-1: 1993 with MID certification. The meters shall be capable of transmitting consumption data on daily basis to central server through GSM/GPRS. The meter interface unit shall be fitted to the meter without wire. The consumption data shall be collected , stored and analysed by data logger. The data logger should provide data like flow rate, total flow, consumption analyses, reverse flow, meter tampering, daily flow distribution, leakage detection. The data logger shall also send alams on blocked meter, flow rate above limit, pressure below or above limits. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 100 mm dia.

3

25531

76593

... More
code66 - Cutting Cement Concrete road surfaces for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the classifications for. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

215.9

951

205320.9

... More
code67 - Cutting Asphalt Concrete road surfaces for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the classifications for. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

100.4

816

81926.4

... More
code68 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. ORDINARY SOIL.

263.75

371

97851.25

... More
code69 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. HARD SOIL.

263.75

371

97851.25

... More
code70 - Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

1230.5

194

238717

... More
code71 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 63 mm dia.

5875

168

991935

... More
code72 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 75 mm dia.

1580

213

336634.8

... More
code73 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 90 mm dia.

866.3

277

240294.294

... More
code74 - Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 110 mm dia.

896.19

406

363871.0638

... More
code75 - Supply and delivery of 63 mm dia Electrofusion Coupler. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

165

120

19800

... More
code76 - Supply and delivery of 75 mm dia Electrofusion Coupler. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

44

153

6732

... More
code77 - Supply and delivery of 90 mm dia Electrofusion Coupler. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

24

197

4728

... More
code78 - Supply and delivery of 63 mm dia Electrofusion TEE. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

17

210

3570

... More
code79 - Supply and delivery of 75 mm dia Electrofusion TEE. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

2

306

612

... More
code80 - Supply and delivery of 90 mm dia Electrofusion TEE. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

1

451

451

... More
code81 - Supply and delivery of 63 mm dia Electrofusion ELBOW. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

25

211

5275

... More
code82 - Supply and delivery of 75 mm dia Electrofusion ELBOW. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

7

246

1722

... More
code83 - Supply and delivery of 90 mm dia Electrofusion ELBOW. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

3

387

1161

... More
code84 - Supply and delivery of 63 mm dia Electrofusion REDUCER. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

15

240

3600

... More
code85 - Supply and delivery of 75 mm dia Electrofusion REDUCER. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

10

377

3770

... More
code86 - Supply and delivery of 3 inch flange. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

30

200

6000

... More
code87 - Supply and delivery at site GM (copper alloy) 80 mm dia gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 80 mm dia gate valve

12

1902

22824

... More
code88 - Supply and delivery at site GM (copper alloy) 100 mm dia gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

2

1962

3924

... More
code89 - Supplying and fixing 80 mm dia kinetic AIR VALVE PN 16.0 for automatic discharge of accumulate air during working condition, conforming to IS 14845 / EN 1074-4. Body and bonnet of DI conforming to IS-1865 of grade GGG-40/50, seals are made of approved EPDM, SS 304 float, guide and internals. Flange drilling according to IS-1538 with appurtenances. complete. Body and bonnet shall be coated with electrostatically applied epoxy powder coating with a coating thickness of 250 micron both inside and outside. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

1

2700

2700

... More
code90 - Supply and fixing of fixed height surface box H-4057 MD-KU with PP 40% GF Lid, Housing of PA+, Locking clip of PP with Notched bolt M 12 x 130 hexagon head A2-70 for service connection valves, design derived from DIN 4057, should be supplied with Support tile I (FSL, FSS, SI). Should be able to receive class AA traffic loads. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

15

2731

40965

... More
code91 - Providing, Laying and Fixing GI 100 mm dia pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing). including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 100 mm dia.

90

1305

117500.4

... More
code92 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

1200.9

122

146509.8

... More
code93 - Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

183

2288

418704

... More
code94 - Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 m3 capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. M20 (Grade).

366

6152

2251632

... More
code95 - Cutting of road surface for pipeline trenches and disposing of the excavated stuff as directed including barricading, danger lighting etc. in the following classification. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

142.2

951

135232.2

... More
code96 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

284.4

371

105512.4

... More
code97 - Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-In- Charge. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 20 mm dia pipes.

3160

180

568800

... More
code98 - Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-In- Charge. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 25 mm dia pipes.

1185

227

268995

... More
code99 - Providing and fixing of Electro fusion saddle company Tapp with BS EN12201 -3:2011, PN 12.5 rating and food grade raw material as per BS 6920 with material of construction PE 80 or PE 100 and colour of fitting - Blue/Black for water applications, EF tapping saddle is V-regarding type. Designed to fuse at a fusion voltage 40 volt AC EF tapping Sadlle is fused shall have moulded SS/Brass metal female threaded outlet. EF tapping saddle is fused by using a top loading piller type pressure exerting 1500 N (150kg aprox.) top load on EF saddle. fusion time is 170 secs and cooling time is 10mins , exerted pressure should be removed after completing the 10 min cooling time. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 63x20 63 mm dia.

790

350

276500

... More
code100 - Supply of PPR Male threded coupling confirming to IS 15801-2008 and DIN standards 8077/8092. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 20mm dia.

790

82

64780

... More
code101 - Supply of PPR Female threded coupler confirming to IS 15801-2008 and DIN standards8077/8092. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 20mm dia.

3160

59

186440

... More
code102 - Supply of PPR Female threded coupler confirming to IS 15801-2008 and DIN standards8077/8092. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 25mm dia.

225

66

14850

... More
code103 - Supply of PPR 4way/cross TEE confirming to IS 15801-2008 and DIN standards. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

790

29

22910

... More
code104 - Supply of PPR Female threded elbow confirming to IS 15801-2008 and DIN standards 8077/8092. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 20mm dia.

790

56

44240

... More
code105 - Supply of PPR End Cap confirming to IS 15801-2008 and DIN standards 8077/8092. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

790

11

8690

... More
code106 - Supply of PPR Plain union cap confirming to IS 15801-2008 and DIN standards 8077/8092. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 20mm dia.

790

58

45820

... More
code107 - Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS 13.2.2 / 13.3. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. 20 mm dia.

790

345

272550

... More
code108 - Supply and fixing of HDPE water meter box with locking arrangement to protect the water meter of Class ‘B’ Multijet type of size 15 to 32 mm including HDPE box with base dia 300mm x lid dia 200mm x height 250mm with openable lid and the cover is buried below GL with lid flush with GL including earth work excavation for 600mm x 600mm and base sand filling for 100mm thick over which the cover is placed and enclosed by PCC 1:2:4 using 12-20mm BG jelly for an height of 150mm and refilling with excavated earth for balance 100mm height, disposal of excess earth with all lead and lifts with appurtenances complete as per drawing enclosed. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

790

509

402110

... More
code109 - Supplying and fixing Multijet class B inferential type, AMR compatible water meters with IP 68 protection totalizer confoming to IS 779 with its latest amendments of following size to service connections including conveying and fixing of necessary G.I. specials with appurtenances complete, with all lead and lift. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

790

1649

1302710

... More
code110 - Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

790

378

298620

... More
code111 - Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

87.406

2288

199984.928

... More
code112 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, plywood / steel formwork, cost of all materials of quality, labour, Usage charges of machineries, curing and all the other appurtenances required to complete the work as per technical specifications. ( The cost of steel reinforcement shall be paid separately). including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. PCC 1:1.5:3 using 20 mm aggregate.

72.85

6279

457492.172

... More
code113 - Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 m3 capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. M20 (Grade).

142.2

6152

874814.4

... More
code114 - Supplying and fixing of RCC demarcation stones of 30 cms x 15 cms and 90 cms deep using 1:2:4 cc and 6 mm dia rods for verticals and stirrups and rendered smooth, including engraving letters "KWB and Arrow" 6mm deep on the top including fixing demarcation stones 45 cms below ground level and CC 1:3:6, 15 cms height with 8 cms offset around the stone and curing for 10 days including earthwork excavation in all types of soils with all lead and lift. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. RCC demarcation stones of 30 cms x 15 cms and 90 cms.

790

440

347600

... More
code115 - Supply and fixing pot rest slab of size 0.45 X 0.30 X 0.20 meters with central dip for resting the pot including two line dressing and edges rounded and with all lead. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. pot rest slab of size 0.45 X 0.30 X 0.20 meters.

474

513

243162

... More
code116 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

84.39

90

7595.1

... More
code117 - Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work.

142.2

1

170.64

... More
code118 - Flow Control valve 5LPm/10LPM/15LPM:Providing and fixing Flow control valve using food grde materials SS 316 ball / 1/2" [15mm] including cost of all materials, labour charges, HOM and testing complete as per of following specification. The ELV nominal design is range of 7 lt/Min at 1 bar or more pressure MOC of valve food grade stainless steel SS 316 MOC of ball stainless steel-316 flow direction arrow embossed on its outside surface. The Valve should act as flow control valve and non-return valve. including cost of all materials, labour, transportation and other incidental charges incur during the execution of work and as per directions of Engineer incharge of work. ( Approved rate ). Flow Control valve 5LPm/10LPM/15LPM.

790

255

201450



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.