Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 12,700Document Cost
Refer DocumentsTender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
RDPR/2024-25/BD/WORK_INDENT9824Bid Award Id
ViewTender No
RDPR/2024-25/BD/WORK_INDENT9824Tender Authority
Rural Development And Panchayat Raj Department ViewPurchaser Address
-Website
http://https://www.tnrd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
PRE04 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24, V-2, I No.8.8, P-42)
11.25
389
4382.4375
PRE05 - Cudddapah slab 2.5cms thick. (PWD SR 2023-24, V-2, Item No.261, Page No.A-19)
6.75
485
3274.425
PRE06 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.(PWD SR 2023-24, V-2, I No.11.35.2.2, P-88)
42.3
599
25360.965
PRE07 - Providing and supplying cupboard shutter with 18mm thick one side Architect recommended decorative laminate (1mm thick) and other side balancing lamination(preferably white) HDHMR BO ARD of approved brand complete as per direction of engineer in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately) (PWD SR 2023-24, V-2, I No.22.5, P-217)
33.6
2824
94903.2
PRE08 - Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer- in-charge: Pre-laminated particle board with decorative lamination on both sides including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(PWD SR 2023-24, V-2, I No.11.36.2, P-89)
3.905
1032
4030.54575
PRE09 - Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications. (PWD SR 2023-24, V-2, I No.11.37.3, P-89)
3.55
1370
4864.3875
PRE10 - Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. (PWD SR 2023 24, V-3, I No: 3.7, P-17)
21.762
110
2399.2605
PRE11 - Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water,all materials,usage& all other appurtenaces required to complete the work. (PWD SR 2023-24, V-1, I No: 1.8, P-7)
29.016
497
14441.2632
PRE12 - Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density. By Manual Means,Grading-II (53 mm to 22.4 mm), Using Screening Type B (11.2mm agg). (PWD SR 2023-24, V-3, I No: 4.13 A (ii) b, P-26)
10.881
2886
31407.46245
PRE13 - Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA & for Residential Streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (WMM/WBM Base to be paid separately as per relevant technical specification) (PWD SR 2023-24, V-3, I No: 6.8.2, P-51)
145.08
1219
176859.774
PRE14 - Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 250 x 100 mm size. (PWD SR 2023-24, V-3, I No: 8.42.1, P-74)
34.3
318
10912.545
PRE15 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes. (PWD SR 2023-24, V-2, I No: 13.32.2, P-122)
30
397
11938.5
PRE16 - Providing and fixing white vitreous china wash basin including making all connections but including the cost of fittings : Flat back wash basin of size 630x450 mm. (PWD SR 2023-24, V-2, I No: 14.25.1, P-135)
2
1035
2070.6
PRE17 - Concealed Conduit System Supplying heavygauge PVC conduit pipe..... mm dia....... mm thick confirming toIS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc.,and running before concreting thes lab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures ,run with 18 SWGGI fish wire wherever necessary-25 mm dia 2 mm thick. (PWD EL SR. 2023-24, Vol-6, I No-1.2.2, P No-2)
80
78
6240
PRE18 - Supplying heavy gauge PVC Conduit Pipe....dia.......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall andf ixing by bracing UorJ hooks and cement plastering upto the wall surface and run with18SWGGI fishwire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick. (PWD EL SR. 2023-24, Vol-6, I No-1.3.2, P No-2)
80
79
6320
PRE19 - Supplying and fixing PVC/metal conduit Deep junction box. 25 mm deep Junction box. (PWD EL SR. 2023-24, Vol-6, I No-1.5.2, P No-3)
5
56
280
PRE20 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick / Stone/C.C wall. 1-2 Way.(PWD EL SR. 2023-24, Vol-6, I No-3.4.1, P No-8)
5
103
515
PRE21 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) &1x1.0sqmm (Earthwire) FRLS multi strand PVC insulated copper wire (confirmingtoIS-694:and latest amendments) without control switch shallbe fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box. (PWD EL SR. 2023-24, Vol-6, I No-2.2.1, P No-5)
10
269
2690
PRE22 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) &1x1.0sqmm (Earthwire) FRLS multi strand PVC insulated copper wire (confirmingtoIS-694:and latest amendments) without control switch shallbe fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to outlet vias witch box. (PWD EL SR. 2023-24, Vol-6, I No-2.2.2, P No-5)
8
379
3032
PRE23 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) &1x1.0sqmm (Earthwire) FRLS multi strand PVC insulated copper wire (confirmingtoIS-694:and latest amendments) without control switch shallbe fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto10Mtr from tapping point to outlet via switch box. (PWD EL SR. 2023-24, Vol-6, I No-2.2.3, P No-5)
8
555
4440
PRE24 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 mm2. (PWD EL SR. 2023-24, Vol-6, I No-2.3.2, P No-5)
190
26
4940
PRE25 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 mm2. (PWD EL SR. 2023-24, Vol-6, I No-2.3.3, P No-5)
190
42
7980
PRE26 - Supplying 6A flush type socket and 6A flush type SP switch either surface / flush mounting in existing gang box or in 4mm thick plastic sheet and fixing overa flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854. 6A 2 Way. (PWD EL SR. 2023-24, Vol-6, I No-3.1.1, P No-8)
15
128
1920
PRE27 - Supplying and mounting 2 Nos. of 2Way 6 A flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 1293. (PWD EL SR. 2023-24, Vol-6, I No-3.2, P No-8)
10
170
1700
PRE28 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A SP Switch. (PWD EL SR. 2023-24, Vol-6, I No-3.14.1, P No-10)
10
55
550
PRE29 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 32A Bakelite DP. (PWD EL SR. 2023-24, Vol-6, I No-3.14.14, P No-10)
10
232
2320
PRE30 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket. (PWD EL SR. 2023-24, Vol-6, I No-3.6.10, P No-9)
10
236
2360
PRE31 - Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws. (PWD EL SR. 2023-24, Vol-6, I No-3.8, P No-9)
5000
-
2050
PRE32 - Supplying of..... feet PVC Batten with integrated LED tube....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater than 80.Power Input : 220-240V@50/60Hz & Power factor Greater than 0.9 along with CE approved.2yearsWarranty against any manufacturing defect working unde rstandard electrical condition. LED light fitting 1 x 2feet - 9/10 W. (PWD EL SR. 2023-24, Vol-6, I No-11.3.1, P No-43)
2
551
1102
PRE33 - Supplying & fixing of retro fit type-LED bulb......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K,CRI Greater than 70%. efficacy Greater than 80 lumenper W, life Greater than 25000 burning hours and Compliance to IS 10322 / IEC60598, LM79 & LM80. The LED are driven by HF electronic driver integrated in the system, with PF Greater than 0.95, power loss should Less than5% of lamp Wage., shortcircuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM79. The operating input voltage should be between 130 to 275V. BIS Approved and Tested by NABL / CPRI accredited laboratory with 2years Warranty against any manufacturing defect working under standard electrical condition. 12W, 6500K (PWD EL SR. 2023-24, Vol-6, I No-11.11.5, P No-47)
5
269
1345
PRE34 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230V, 50cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model. (PWD EL SR. 2023-24, Vol-6, I No-6.3.1, P No-30)
1
2984
2984
PRE35 - Supplying wall mounting fan suitable to operate at single-phase 230v AC. supply.400 mm Sweep. (PWD EL SR. 2023-24, Vol-6, I No-6.5.2, P No-30)
5
3212
16060
PRE36 - Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps On wall/ ceiling / Rafter / Girders. (PWD EL SR. 2023-24, Vol-6, I No-13.7.1, P No-56)
2
122
244
PRE37 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing feetSfeetfeet hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. (PWD EL SR. 2023-24, Vol-6, I No-13.10, P No-57)
1
171
171
PRE38 - Supplying...litres capacity vertical/horizontal type wall mounting Electrical water heater with 22SWG copper/SS sheet metal inner Container tinned inside Fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence.The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with aneon indicator fitted with 20A capacity 25to85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3core copper flexible wire of 1.5meters length and the outer container provided with heavy gauge brackets for wall mounting. 5 Star With Fibre body.25 L.(PWD EL SR. 2023-24, Vol-6, I No-7.2.1, P No-34)
1
11929
11929
PRE39 - Supply of LED flood light luminaire with pressure diecast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of antiglare clear diffuser with Injection moulded polycarbonate / clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT Greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire Greater than IK 08. Power Factor Greater than 0.9 with mains, Surge Protection-Min 5KV along with Over voltage / Over load, short circuit / miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from100V to 270V50/60Hz application. Compliance to IS10322/IEC60598, LM79 & LM80 Adherence with Ro HS.UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with.......W System Power consumption. LED Efficiency Greater than 1301m/w, nominal CRI Greater than 75.Luminaire manufacturer should have in -house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008.Housing with supplier wordmark / name shall be Engraved / Embossing on the diecast housing/Body part Warranty of 2 Years against any manufacturing defect working understandard electrical conditions as mentioned above should be given by LED manufacturer & Cree /Nichia / Lumileds / Osram make LED Source. LED Flood light 120W(PWD EL SR. 2023-24, Vol-6, I No-11.9.3, P No-46)
2
10757
21514