Rural Development And Panchayat Raj Department Tender
... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Rural Development And Panchayat Raj Department - RDPR Tender
Civil And Construction
Water Storage And Supply
Opening Date1 Feb 2025
Closing Date11 Feb 2025
Tender Amount₹ 8,05,831.64
Costs
EMD
₹ 20,150Document Cost
Refer DocumentsTender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
RDPR/2024-25/BD/WORK_INDENT12616Tender No
RDPR/2024-25/BD/WORK_INDENT12616Tender Authority
Rural Development And Panchayat Raj Department ViewPurchaser Address
-Website
http://https://www.tnrd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
code04 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (P.No.9/I.No.5.4 Volume-2 PWD SR 2023-24)
3.2
6389
20444.8
... More
code05 - Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (P.No.7/I.No.1.11 olume-1 PWD SR-2023-24)
8.89
433
3849.37
... More
code06 - Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, per directions of Engineer-in-charges (P.No.44/I.No.8.19.1 Volume-2 PWD SR 2023-24)
10.02
255
2555.1
... More
code07 - Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.15/I.No.2.3.1 Volume-1 PWD SR 2023-24)
0.47
9484
4457.715
... More
code08 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (P.No.17/I.No.6.33 Volume-2 PWD SR-2023-24)
39.2
1231
48255.2
... More
code09 - Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.15/I.No.2.3.1 Volume-1 PWD SR 2023-24)
0.84
7587
6373.584
... More
code10 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates (P.No.78/I.No.2.5.1 Volume-1 PWD SR-2023-24)
3.6
9945
35802
... More
code11 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates (P.No.78/I.No.2.5.1 Volume-1 PWD SR-2023-24)
0.36
9613
3460.86
... More
code12 - Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification a) Buildings (P.NO.18.I.NO.2.11 PWD SR 2023-24 Volume-1)
0.624
89457
55821.168
... More
code13 - Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P.No.41/I.No.8.3.1Volume-2 PWD-2023-24)
81.63
354
28897.02
... More
code14 - Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (P.No.60/ I.9.12.2 Volume-2 PWD SR 2023-24)
14.8
1145
16946
... More
code15 - Supplying and fixing rolling shutters of approved make made of required size MS laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 part 1 and MS top cover of required thickness for rolling shutters 80 1.25 mm MS laths with 1.25 mm thick top cover including cost of materials labour usagecharges of machinery complete as per specifications and as per directions of the Engineer in Charge P.No.78 I. No.11.6.1 Volume 2 PWD SR 2023-24
6.3
2633
16587.9
... More
code16 - Extra for providing mechanical device chain and crank operation for operating rolling shutters: Exceeding 10.00 m² and upto 16.80 m² in the area including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No.78/ I. No.11.8.1 Volume-2 PWD SR 2023-24)
3
987
2961
... More
code17 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. (P.No.86, I.No.11.34 B Volume-2 PWD SR 2023-24)
90.72
183
16601.76
... More
code18 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. (P 89/ I.11.35.2.3 Volume-2 PWD SR 2023-24)
69.3
582
40332.6
... More
code19 - Providing and fixing double glazed hermetically sealed glazing in alu-minium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No.91/I.No.11.44 Volume-2 PWD SR-2023-24)
4.32
4345
18770.4
... More
code20 - Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in-cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (It No.8.25 Page No-45 Volume-02 PWD SR-2023-24)
98.13
137
13443.81
... More
code21 - Providing Vertical Delineator having wide angle cube corner micro prismatic non metallic reflective sheeting confirming to Type XI of ASTM D4956 -09 with White Color and Red Color combination and having minimum of retro reflective exposed area of 125 Sq CM on top slots and 35 cm2 on bottom slots and no edges shall be exposed for tampering. This tubular delineator shall have a core and shell construction, shell shall be made of tough, high impact resistant, injection-molded, thermoplastic outer body and the inner core shall consist of powder coated or painted Mild steel of minimum thickness 1.0mm.and core shell structure shall be of height not less than 800 mm above the ground and width not less than 80 mm. The metallic core of the delineator shall extend 300mm beyond the shell length from bottom for installing in the ground. The extended portion shall have slots to insert anchoring rods for enhancing the concrete grip. The logo of the manufacturer shall be embossed on either side of the body in the injection molding process. The engineering thermoplastic used for making the delineator body shall have minimum initial mechanical properties of be fixed by a combination of epoxy adhesive and grouting as per MoRTH specification 806 (P.No.75 I. No. 8.45 Volume-3 PWDSR-2023-24)
1
2900
2900
... More
code22 - Pipeline Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and leveling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 m (P.No.10/ I. No.1.17.1 Volume-1 PWDSR-2023-24)
33
262
8646
... More
code23 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For PVC pipes 75mm dia., 6 kg/sqcm & class 3 (P.No.113/ I.No.10.1.5 Volume-5 PWD-2023-24)
110
220
24200
... More
code24 - Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. (P.No.2/ I. No. 1.1.2 Volume-2 PWD Ele SR 2023-24)
40
81
3240
... More
code25 - Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 8" x 6" x 3" (203 x 152 x 76 mm) (P.No.3/ I. No. 1.6.4 Volume-6 PWD Ele SR 2023-24)
6
86
516
... More
code26 - Point wiring using Copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet (P.No.5/ I. No. 2.1.1 Volume-6 PWD Ele SR 2023-24) 2.1.1 Point wiring using class A Materialsa) Short point up to 3Mtr from tapping point to out let via switch
1
285
285
... More
code27 - Point wiring using Copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet (P.No.5/ I. No. 2.1.1 Volume-6 PWD Ele SR 2023-24) 2.1.1 Point wiring using class A Materialsa) Point wiring using class A Materials b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch
2
394
788
... More
code28 - Point wiring using Copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet (P.No.5/ I. No. 2.1.1 Volume-6 PWD Ele SR 2023-24) 2.1.1 Point wiring using class A Materialsa) Point wiring using class A Materials b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch Point wiring using class A Materials c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch
4
570
2280
... More
code29 - Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way (P.No.8/ I. No. 3.1.2 Volume-6 PWD Ele SR 2023-24)
2
147
294
... More
code30 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 Way (P.No.8/ I. No. 3.3.3 Volume-6 PWD Ele SR 2023-24)
2
137
274
... More
code31 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way (P.No.8/ I. No. 3.3.4 Volume-6 PWD Ele SR 2023-24)
2
173
346
... More
code32 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2 (P.No.5/ I. No. 2.3.3, 2.3.3 & 2.3.5 Volume-6 PWD Ele SR 2023-24) 2.3.2 1.5 sqmm (Copper wire)
70
26
1820
... More
code33 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2 (P.No.5/ I. No. 2.3.3, 2.3.3 & 2.3.5 Volume-6 PWD Ele SR 2023-24) 2.3.3 2.5 sqmm (Copper wire)
30
42
1260
... More
code34 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2 (P.No.5/ I. No. 2.3.3, 2.3.3 & 2.3.5 Volume-6 PWD Ele SR 2023-24) 2.3.5 6 sqmm (Copper wire)
60
92
5520
... More
code35 - Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws. (P.No.9/ I. No. 3.8 Volume-6 PWD Ele SR 2023-24)
1500
-
615
... More
code36 - Supplying and fixing PBBC bakelite straight or slant batten holder and wiring, within 60w/230 Volts lamps. Group 'A' (P.No.20, I.No.4.2)
4
88
352
... More
code37 - Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours 70 lumen maintenance with CR 80 Power Input: 220 240V 50 60Hz Power factor 0.9 along with CE approved 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1 4 20 22 W (P.No.43 I. No.11.3.2 Volume 6 PWD Ele SR 2023-24
3
690
2070
... More
code38 - Supplying decorative horizontal type street light flourcent fitting weather and water proof complete with energy saving electronic ballast etc., locking type bross contact holers with one number of 4ft 40wt flourcent tube completely wired for use on 230/250 volts 50 cycles AC supply with opal reeded perspex cover at bottom complete fitting 1x4' - 36/40wts (P.No.21, I.No.4.10.1)
2
1866
3732
... More
code39 - Fixing all types and all capacities of fluorescent/false ceiling/spot light/CFL fittings indoor on the wall / ceiling/ rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps (if required) a) On wall/ceiling/Rafter/Girders (P.No.58/ I. No. 13.7.1 Volume-6 PWD Ele SR 2023-24)
3
122
366
... More
code40 - Supplying and Fixing........mm dia clampsss A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires Using 25mm dia G.I.Pipe (P.No.56/ I. No. 13.2.1 Volume-6 PWD Ele SR 2023-24)
2
1203
2406
... More
code41 - Supply and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. a) 20"x20"x2.5" (P.No.44/ I. No. 5.6.6 Volume-6 PWD Ele SR 2023-24)
2
326
652.26
... More
code42 - Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 32 A (P.No.14/ I. No. 5.7.2 Volume-6 PWD Ele SR 2023-24)
2
241
482
... More
code43 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. (P.No.17/ I. No. 5.18.4 Volume-6 PWD Ele SR 2023-24) 5.17.4 6-32 A DP
1
739
739
... More
code44 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. (P.No.17/ I. No. 5.18.4 Volume-6 PWD Ele SR 2023-24) 5.17.3 50-63 A SP
4
811
3244
... More
code45 - Supplying fixing and wiring Electronic Trivector Meter(ETV 5 to 20A single phase Class 1 Accuracy withTemper Proof Energy Meter (P.No.19 I. No. 5.30 Volume 6 PWD Ele SR 2023 24)
1
1380
1380
... More
code46 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia (P.No.54/ I. No.12.56 Volume-6 PWD Ele SR 2023-24)
2
3510
7020
... More
code47 - GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 3 mm GI strip (P.No.54/ I. No.12.58.2 Volume-6 PWD Ele SR 2023-24)
15
77
1155
... More
code48 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) (P.No.13/ SI. 201 I.No.32.056 Volume-6 PWD Ele SR 2023-24)
25
155
3886.25
... More
code49 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 Sqmm (P.No.52/ SI. No.170 I.No.21.05 Volume-6 PWD Ele SR 2023-24)
25
20
522.25
... More
code50 - Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) In soil (hard) (P.No.70, I.No.7.9.2)
20
106
2120
... More
code51 - Supplying and fixing of class A (medium duty) GI pipe of wall thick ness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV class. 40mm (P.No.70, I.No.7.12.1)
5
345
1725
... More
code52 - Straight Through Jointing Kit Suitable for 1.1 kV Class LTUG Cable as per IS-13573 16 Sqmm, 4 Core (P.No.14/ SI. 232 I.No.34.04 Volume-6 PWD Ele SR 2023-24)
1
577
577
... More
code53 - Water purification plants Supplying, Installation and Commissioning of automatic Water purification plant RO UF)with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2All items are to be of BSI NFS standards,with BSI NFS mark 3 Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components (UNI SR VOL.5 2023-24, P.247, SI.NO. 21.1.8)
1
307000
307000