Rural Development And Panchayat Raj Department Tender
... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 16,875Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
RDPR/2022-23/BD/WORK_INDENT94487Tender No
RDPR/2022-23/BD/WORK_INDENT94487Tender Authority
Rural Development And Panchayat Raj Department ViewPurchaser Address
-Website
http://https://www.tnrd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
0.97
-
9262.65
... More
Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
9.73
-
80842.78
... More
Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
904.75
-
97278.72
... More
Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
14.28
-
85597.75
... More
Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
15.09
-
6454.45
... More
Providing and constructing laterite size stone Masonry including cost and conveyance of materials etc complete as per specification FOR BASEMENT in CM 1:6 With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
16.86
-
111467.53
... More
Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
157.21
-
48596.76
... More
Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
64.21
-
14239.21
... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
108
-
19232.64
... More
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
7.2
-
28070.78
... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
44
-
53567.36
... More
Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
2.21
-
9554.27
... More
Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
0.05
-
4219.26
... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
221.42
-
23559.09
... More
Concealed Conduit System Supplying heavy guage PVC conduit Pipe………….mm dia ………….mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforement rods by using binding wires and unused ways of junction rods by using binding wires and unused ways of junction boxes and pipes ends should be covered using PVC end enclosures, run with 18 SWG GI fish wire wherever necessary 19/20mm dia 2mm thick With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
30
-
1200
... More
Supplying heavy guage PVC Conduit Pipe……….dia……….mm thick with suitable size bends, metal junction boxes adhesive paste etc. by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 19/20mm dia 2 mm thick With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
30
-
1530
... More
Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Group A Short Point upto 3 Mtr from tapping point to out let via Switch With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
2
-
400
... More
Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Group A Medium Point above 3 Mtr upto 6 Mtr from tapping point to out let via switch With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
2
-
550
... More
Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. Group A Long Point above 6 Mtr upto 10 Mtr from tapping Point to out let via switch With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
2
-
800
... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. " A" 6Amps One way. With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
5
-
350
... More
Supplying and fixing of modular switch & connectedaccessories on existing modular switch plate as per IS 3854 and IS 1293. " A" Stepped Fan Regulator.With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
5
-
1450
... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 sqmm With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
20
-
410
... More
Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired.Excluding Ballast & Flouresent Tube.1 x 4' Tube light fitting. With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
4
-
900
... More
Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V @ 50/60Hz & Power factor >0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
4
-
1500
... More
Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles, Single phase AC supply conforming ot ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
3
-
6270
... More
Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
5
-
750
... More
Supplying and fixing regular MCB distribution boards on wall/wood board/flush mounting using required clamps, bolts, nuts etc. with provision for fixing suitable type capacity MCB's single phase/3 Phase/single door with powder coated painting. Made out of 14 SWG MS enclosure II- Double Door 12 Way SP & N With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
1
-
1800
... More
Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia With All Lead And Lifts , loading and un loading charges complete as per the directions Of Engineer Incharge Of Work ---- With All Lead and Lift, Loading and Unloading Charges etc., all are as per the Direction of Engineer In Charge of the Work.
1
-
2999.7