Rural Development And Panchayat Raj Department Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Rural Development And Panchayat Raj Department - RDPR Tender

Works
Civil And Construction
Water Storage And Supply
Opening Date5 Nov 2024
Closing Date12 Nov 2024
Tender Amount₹ 5,91,986.81 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Providing and laying Vitrified tiles with thickness 9 10 mm in different sizes with water absorption less than 0.08 % and conforming to I S 15622 of approved make in all colours & shade over 12 mm thick bed of cement mortar 1:3 1 cement 3 coarse sand jointing with grey cement slurry @ 3.3 kg m2 including grouting the joint with white cement & matching pigments etc complete Size of Tile 600x600 mm with all lead, lifts loading & unloading charges including cost and conveyance of all materials labour equipments HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

35.39

1175

41583.25

... More
code05 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 thickness to be specified by the manufacturer of approved make in all colours shades except burgundy bottle green black of any size as approved by Engineer in Charge in skirting risers of steps and dados over 12 mm thick bed of cement mortar 1:3 1 cement 3 coarse sand and jointing with grey cement slurry @ 3.3kg/m2 including pointing in white cement mixed with pigment of matching shade complete with all lead lifts loading & unloading charges including cost and conveyance of all materials labour equipments, HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer in charge of the work

79.22

1106

87617.32

... More
code06 - Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia etc complete with all lead lifts loading & unloading charges including cost and conveyance of all materials labour equipments HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

80

113

9040

... More
code07 - Providing and fixing GI chain link fabric fencing of required width in mesh size 25x25 mm made of G I wire of dia 3 mm including strengthening with 2 mm dia wire or nuts bolts and washers as required complete as per the direction of Engineer-in-charge with all lead lifts loading & unloading charges including cost and conveyance of all materials labour equipments HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

22.2

893

19824.6

... More
code08 - Providing and fixing wash basin with CI brackets 15 mm C P brass pillar taps 32 mm C P brass waste of standard pattern including painting of fittings and brackets cutting and making good the walls wherever require White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps with all lead lifts loading & unloading charges including cost and conveyance of all materials labour equipments HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

2

2866

5732

... More
code09 - Providing and fixing kitchen sink with C.I. brackets C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets cutting and making good the walls wherever required: 14.9.1 White glazed fire clay kitchen sink of size 600x450x 250 mm with all lead lifts loading & unloading charges including cost and conveyance of all materials labour equipments HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

1

2981

2981

... More
code10 - Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I brackets and stainless steel plug 40 mm including painting of fittings and brackets cutting and making good the walls wherever required 610x460 mm bowl depth 200 mm with all lead lifts loading & unloading charges including cost and conveyance of all materials labour equipments HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

1

2840

2840

... More
code11 - Providing and fixing Unplasticised Polyvinyl Chloride uPVC pipes for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement trenching refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes with all lead lifts loading & unloading charges including cost and conveyance of all materials labour equipments HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work

30

224

6720

... More
code12 - Providing and fixing Unplasticised Polyvinyl Chloride uPVC pipes for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement trenching refilling & testing of joints complete as per direction of Engineer in Charge External work 20 mm nominal dia Pipes with all lead lifts loading & unloading charges including cost and conveyance of all materials labour equipments HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

30

172

5160

... More
code13 - Making connection of GI distribution branch with G.I main of following sizes by providing and fixing tee including cutting and threading the pipe etc complete 20 mm nominal bore with all lead lifts loading & unloading charges including cost and conveyance of all materials labour equipments HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer in charge of the work

8

305

2440

... More
code14 - Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work two coats over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer-in-charge with all lead lifts loading & unloading charges including cost and conveyance of all materials labour equipments HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

248.43

137

34034.91

... More
code15 - Finishing walls with water proofing cement paint of required shade New work Two coats applied @ 4.84 kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge with all lead lifts loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

112.99

89

10056.11

... More
code16 - 8.40 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials labour complete as per specifications and as per directions of Engineer-in-charge with all lead, lifts loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

169.21

115

19459.15

... More
code17 - Providing and fixing water closet squatting pan Indian type W.C. pan with 100 mm sand cast Iron P or S trap 10 litre low level white P.V.C flushing cistern including flush pipe with manually controlled device handle lever conforming to IS 7231 with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 14.1.1 White Vitreous china Orissa pattern W.C pan of size 580x440 mm with integral type foot rests with all lead lifts loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

2

4884

9768

... More
code18 - Electrical Work Concealed Conduit System :Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends metal PVC Junction boxes adhesive paste etc and running before concreting the slab The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick with all lead lifts loading & unloading charges including cost and conveyance of all materials, labour equipments HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer in charge of the work

50

53

2650

... More
code19 - Supplying heavy gauge PVC Conduit Pipe dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. - 25mm dia 2mm thick with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

50

54

2700

... More
code20 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5Sqmm Phase & Neutral & 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694 and latest amendments without control switch shall be fixed on the existing plastic sheet/ gang box the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block complete for each outlet Short point upto 3Mtr from tapping point to out let via switch box with all lead lifts loading & unloading charges including cost and conveyance of all materials labour equipments HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

8

160

1280

... More
code21 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5Sqmm Phase & Neutral & 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS-694 and latest amendments without control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box with all lead, lifts, loading & unloading charges including cost and conveyance of all materials labour equipments HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

8

250

2000

... More
code22 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5Sqmm Phase & Neutral & 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

8

375

3000

... More
code23 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index IS 694-1990, Clause 16.13 Smoke Density IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12 - 1.5 sqmm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer-in-charge of the work

25

20

512.5

... More
code24 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12 - 2.5 sqmm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer-in-charge of the work

30

32

960

... More
code25 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.The following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting uthority.Additional Tests for FRLS-Applicable Standard Oxygen Index -IS 694-1990, Clause 16.8 Temperature Index -IS 694-1990, Clause 16.13 Smoke Density -IS 694-1990, Clause 16.14 Test for Halogen Acid Gas evaluation -IS 694-1990, Clause 16.12 - 4 sqmm with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer-in-charge of the work

50

45

2250

... More
code26 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. - 8Way with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer-in-charge of the work

10

140

1400

... More
code27 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall, including necessary rawl plugs, Machine NF screws etc complete 10-12Way with all lead lifts loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

10

160

1600

... More
code28 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal PVC box. - 8 Module with all lead, lifts, loading & unloading charges including cost and conveyance of all materials labour, equipments HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

10

200

2000

... More
code29 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc complete on the existing metal PVC box. - 10-12 Module with all lead lifts loading & unloading charges including cost and conveyance of all materials, labour, equipments HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

10

230

2300

... More
code30 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way Switch with all lead lifts loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer-in-charge of the work

10

70

700

... More
code31 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 12936Amps 3way socket with all lead lifts loading & unloading charges including cost and conveyance of all materials, labour, equipments HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

10

105

1050

... More
code32 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 Stepped Fan Regulator with all lead lifts loading & unloading charges including cost and conveyance of all materials, labour equipments, HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

10

290

2900

... More
code33 - Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size mm conduit using necessary machine screws. - 110mm with all lead lifts loading & unloading charges including cost and conveyance of all materials, labour equipments HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer-in-charge of the work

10

11

110

... More
code34 - Supplying capacitor type ceiling fan complete with down rod blades shackle, canopies etc, for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. - 48 Sweep (1200mm) Regular model with all lead lifts loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer-in-charge of the work

5

2090

10450

... More
code35 - Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1 x 4 20/22 w with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer-in-charge of the work

8

375

3000

... More
code36 - Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. - On wall/ ceiling / Rafter / Girders with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer-in-charge of the work

8

110

880

... More
code37 - Fixing a ceiling wall mounting fan of all capacities and all types, with necessary clamps and S hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer-in-charge of the work

8

260

2080

... More
code38 - Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. - 15x12x2 with all lead lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer-in-charge of the work

8

170

1360

... More
code39 - Supplying & fixing of Porcelain fuse channel with cut out on existing woodenpanel using necessary nuts, bolts and washers 32Amps with all lead lifts loading & unloading charges including cost and conveyance of all materials labour equipments HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

8

174

1392

... More
code40 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve indicator ON OFF energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6 32Amps SP with all lead lifts loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer in charge of the work

8

434

3472

... More
code41 - Supplying and fixing regular MCB distribution boards on wall ood board flush mounting using required clamps, bolts, nuts etc with provision for fixing suitable type capacity MCB s single phase 3 phase single door with powder coated painting Made out of 14 SWG MS enclosure 1 Single Door II Double Door Ill Double Door 4Way SP &N with all lead, lifts, loading & unloading charges including cost and conveyance of all materials labour equipments HOM of machinary and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer-in-charge of the work

8

777

6216

... More
code42 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments, HOM of machinary and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer-in-charge of the work

1

2999

2999.7



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.