Rural Development And Panchayat Raj Department Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 50,000Document Cost
Refer DocumentsTender Fee
₹ 500
Summary
Construction Of Valamiki Bhavan At Gumachinamaradi Village Of Hukkeri Taluka Belagavi Dist
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
RDPR/2023-24/BD/WORK_INDENT4467Bid Award Id
ViewTender No
RDPR/2023-24/BD/WORK_INDENT4467Tender Authority
Rural Development And Panchayat Raj Department ViewPurchaser Address
-Website
http://https://www.tnrd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
code04 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per the direction of engineer incharge of work.
4.68
11016
51554.88
code05 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per the direction of engineer incharge of work.
5.44
9720
52876.8
code06 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregate complete as per the direction of engineer incharge of work.
5.3
9484
50267.85
code07 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregate Slab complete as per the direction of engineer incharge of work.
13.6
10116
137588.48
code08 - Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with complete as per the direction of engineer incharge of work.
8.86
6618
58635.48
code09 - Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) complete as per the direction of engineer incharge of work.
9.28
6205
57582.4
code10 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcementincluding cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification complete as per the direction of engineer incharge of work.
3.287
89457
294045.159
code11 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
26.17
7978
208784.26
code12 - Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. complete as per the direction of engineer incharge of work.
50.85
433
22018.05
code13 - Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications complete as per the direction of engineer incharge of work.
0.083
124202
10308.766
code14 - Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) complete as per the direction of engineer incharge of work.
2.52
7444
18758.88
code15 - Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge
256.38
255
65376.9
code16 - Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
233.16
333
77642.28
code17 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. complete as per the direction of engineer incharge of work.
302.4
183
55339.2
code18 - PProviding & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimumTiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. oextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) complete as per the direction of engineer incharge of work.
14.4
5023
72331.2
code19 - Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
256.5
137
35140.5
code20 - Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge
233.16
174
40569.84
code21 - Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm complete as per the direction of engineer incharge of work.
100.5
1145
115072.5
code22 - Providing and applying white cement based putty of average thickness 1 mm, of aproved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
276.38
100
27638
code23 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
28.8
115
3312
code24 - Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
1000
4
4000
code25 - Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existingPVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. I. Point wiring using class A Materials a) Short point up to 3Mtr from tapping point to out let via switch complete as per the direction of engineer incharge of work.
2
285
570
code26 - b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch complete as per the direction of engineer incharge of work.
3
394
1182
code27 - c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch complete as per the direction of engineer incharge of work.
3
570
1710
code28 - Supplying 6 A flush type socket and 6 Amps flush type SP switch either surface / flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 complete as per the direction of engineer incharge of work.
3
147
441
code29 - Supply and fixing of Bakelite DP/ Socket/ Switch with / without neon indicator over existing wood board or flush mounting in plastic plates/ nitches as per IS 1293 and IS 3854 a) 32 Amps Flush / projected type DP switch complete as per the direction of engineer incharge of work.
3
232
696
code30 - b) 16 Amps Flush type Universal Socket complete as per the direction of engineer incharge of work.
3
236
708
code31 - Supplying and fixing ofs lim patty fitting, made out of CRCA Sheetmetal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 1 x 4' Tube light fitting complete as per the direction of engineer incharge of work.
10
269
2690
code32 - Fixing all type sand all capacitie soffluorescent /falseceiling/ spotlight/ CFL/ LED fitting sindoor onthe wall /ceiling/ rafters/ girdersusing 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / Girders complete as per the direction of engineer incharge of work.
5
122
610
code33 - Supply ingand fixing of PVC casing and capping on the wall or ceiling using necessary material slike bends, junction box, elbows, screwsatan interval of 300 mm as required. complete as per the direction of engineer incharge of work.
15
35
525
code34 - Wiring for lighting/ power circuit using one of FRLSPV Cinsulated 1100V grade, multi strand copper wirewith low conduct or resistancesing lecore inopenor concealedsy stem of wiring with specified IS-694:2010 1 mm2 I. Group A Materials a.1 sqmm complete as per the direction of engineer incharge of work.
50
19
950
code35 - b.1.5 sqmm complete as per the direction of engineer incharge of work.
50
26
1300
code36 - c. 2.5 sqmm complete as per the direction of engineer incharge of work.
50
42
2100
code37 - Supplying of LED floodlight with 110 W system power consumption pressure die cast aluminum housing with powder coating with IP 65 protection. 1, 200 - 275 V voltage with electronic Driver, PF 0.9, should meet ANSI 2G Vibration test, Compliance to UL/ CE with Class I system rating shall be 50K hrs Lumen maintenance of 70%, system efficency 80lm / w. Over load & short circuit protection ensures reliable operation in spite of problem in output side. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB.. Top access steet light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED light fixture with 110 W system power consumption. LED efficiency 130 lm/ w at 1 w & fixture efficiency 80lm/ w with nominal CRI 75. Warranty of 5 Yrs. complete as per the direction of engineer incharge of work.
2
18581
37162
code38 - Fixing halogen/ metal halide/ SVL/ IL/ LED floodlight fitting over existing pole/ wall ceiling including clamps, bolts, nuts & wiring using suitable capacity wires. complete as per the direction of engineer incharge of work.
2
162
324
code39 - Supply and fixing polished wood board made of not less than 15mm thick plank on both sides with of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. a) 10" x 8" x 1.5" complete as per the direction of engineer incharge of work.
8
102
816
code40 - Supplying & fixing of Porcelain fuse channel with cut out on existing wooden / panel using necessary nuts, bolts & washers 16 Amps complete as per the direction of engineer incharge of work.
2
157
314
code41 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve , indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required. a) 5-32Amps SP Group 'A" complete as per the direction of engineer incharge of work.
5
415
2075
code42 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting etc., complete. II. Double Door b) 8Way SP &N Group 'A' complete as per the direction of engineer incharge of work.
1
1854
1854
code43 - Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400 x 400 x 400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. complete as per the direction of engineer incharge of work.
2
4256
8512