Rural Development And Panchayat Raj Department Tender
... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Rural Development And Panchayat Raj Department - RDPR Tender
Electrical and Electronics
Electrical Works
Opening Date25 Nov 2024
Closing Date2 Dec 2024
Tender Amount₹ 6,94,508
Costs
EMD
₹ 20,500Document Cost
Refer DocumentsTender Fee
₹ 500
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
RDPR/2024-25/EL/WORK_INDENT10819Bid Award Id
ViewTender No
RDPR/2024-25/EL/WORK_INDENT10819Tender Authority
Rural Development And Panchayat Raj Department ViewPurchaser Address
-Website
http://https://www.tnrd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Code04 - Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.as directed by the engineer-in-charge. 25 mm dia 2 mm thick
75
79
5925
... More
Code05 - WIRES & CABLES Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.as directed by the engineer-in-charge. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box
4
379
1516
... More
Code06 - Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.as directed by the engineer-in-charge. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box
9
555
4995
... More
Code07 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 as directed by the engineer-in-charge. 2.5 mm2
360
42
15120
... More
Code08 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2011 as directed by the engineer-in-charge. 4 mm2
280
63
17640
... More
Code09 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2012 as directed by the engineer-in-charge. 6 mm2
275
92
25300
... More
Code10 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2013 as directed by the engineer-in-charge. 10 mm2
175
167
29225
... More
Code11 - SWITCHES, SOCKETS & ACCESSORIES Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.10-12 Way as directed by the engineer-in-charge.
4
261
1044
... More
Code12 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall as directed by the engineer-in-charge. 10-12 Way
6
319
1914
... More
Code13 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall as directed by the engineer-in-charge. 16 Way
3
363
1089
... More
Code14 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box. as directed by the engineer-in-charge. 10-12 Module
10
344
3440
... More
Code15 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box.as directed by the engineer-in-charge. 16 Module
3
397
1191
... More
Code16 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.as directed by the engineer-in-charge. 6A One Way Switch
32
102
3264
... More
Code17 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.as directed by the engineer-in-charge. 6A Three Way socket
23
171
3933
... More
Code18 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.as directed by the engineer-in-charge. Stepped Fan Regulator Two Module
4
357
1428
... More
Code19 - CONTROL SWITCH GEARS & ACCESSORIES Supplying and fixing HRC fuse units base on existing switch /panel board.as directed by the engineer-in-charge. 32 to 63 A
3
612
1836
... More
Code20 - Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. (Open Execution)as directed by the engineer-in-charge. 200 A
1
13230
13230
... More
Code21 - Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)as directed by the engineer-in-charge. 200 A
1
15249
15249
... More
Code22 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. as directed by the engineer-in-charge. FOUR Pole 200 A 25kA
2
17301
34602
... More
Code23 - Supplying and fixing of Shunt trip suitable for MCCB.CBCT as directed by the engineer-in-charge.
2
1703
3406
... More
Code24 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898.as directed by the engineer-in-charge. 50-63 A SP
5
811
4055
... More
Code25 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898.as directed by the engineer-in-charge. 40 A DP
5
1060
5300
... More
Code26 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898.as directed by the engineer-in-charge. 50-63 A TPN
6
3088
18528
... More
Code27 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount onDIN rail/ flush mounting on panel board.as directed by the engineer-in-charge.
1
9255
9255
... More
Code28 - FANS & AIR CONDITIONERS 15" Sweep (450 mm) as directed by the engineer-in-charge.
2
4446
8892
... More
Code29 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearingsystem.as directed by the engineer-in-charge. 48" Sweep (1200 mm) Regular model
6
2984
17904
... More
Code30 - Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit.as directed by the engineer-in-charge. 2 Ton capacity
4
67399
269596
... More
Code31 - Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type A/C.as directed by the engineer-in-charge.
4
3175
12700
... More
Code32 - Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube.as directed by the engineer-in-charge. Split
20
1549
30980
... More
Code33 - Extra for Fabrication supply and fixing of Stand fabricated using slotted angle /L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit/ Batteries.as directed by the engineer-in-charge.
4
4807
19228
... More
Code34 - NETWORKING & TELECOMUNICATION Supplying and drawing UTP-CAT 6E LAN cable.as directed by the engineer-in-charge.
250
38
9500
... More
Code35 - Supplying & Fixing of switch mounting rack with power manager & Cable manager.as directed by the engineer-in-charge. 9U with 450mm depth
1
8476
8476
... More
Code36 - Supplying fixing of Network Switches as directed by the engineer-in-charge. 48 port 10/100/1000 Switch
1
20300
20300
... More
Code37 - Supplying & Fixing of Patch panel for LAN cabling as directed by the engineer-in-charge. 48 Port 10/100/1000 patch panel
1
24000
24000
... More
Code38 - LUMINAIRS / LIGHT FIXTURES &ACCESSORIES LED Indoor Supplying of .....feet -PVC Batten with integrated LED tube Wwith high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V@ 50/60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.as directed by the engineer-in-charge. LED light fitting 1 x 4'-20/22 W
18
690
12420
... More
Code39 - Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.as directed by the engineer-in-charge.
1
4256
4256
... More
Code40 - GI/Copper strips for grounding connections, using necessary fixing materials as required.as directed by the engineer-in-charge. 600 x 600 x 3 mm Copper plate
1
7421
7421
... More
Code41 - Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires,required Nos of round blocks and clamps.as directed by the engineer-in-charge.
5
490
2450
Evaluation Notes How It Works ?
Potential Partner