Rural Development And Panchayat Raj Department Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Rural Development And Panchayat Raj Department - RDPR Tender

Works
Civil And Construction
Building Construction
Consultancy Services
Civil And Architectural Services
Opening Date7 Dec 2024
Closing Date16 Dec 2024
Tender Amount₹ 18,81,653.86 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.11 - Providing Thermo-Mechanically Treated bars of grade Fe-550D Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (P.No.18/I.No. 2.11 a of PWD SR 23-24.) V-1

0.03

93929

2817.8955

... More
5.3 - Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (1 cement : 6 coarse sand) (P.NO. 9/5.3/PWDSR/2023-24). volume-2

2.31

6515

15050.2275

... More
1.8 - Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.(P.NO. 7/1.8/PWDSR/23-24) volume 1

3.24

497

1612.548

... More
6.32 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (PWD SR 2023-24 Vol-2, P.No.17 I.No.6.32)

33.18

1965

65198.7

... More
2.1.4 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates (P.NO. 15/2.1.4/PWDSR/23-24). volume-1

1.49

6527

9726.4965

... More
8.3.1 - Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. [P.No-41 ,I.No-8.3.1] (PWD SR 2023-24) Volume-2

89.37

371

33218.829

... More
12.93.2 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 65x125mm [P.No- 111,I.No-12.93.2] (PWD SR 2023-24)

19.8

802

15883.56

... More
12.94.1 - Providing and fixing factory made Green certified, Anti Termite, UV resistant,high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness [P.No- 112,I.No-12.94.1] (PWD SR 2023-24 V-2)

6.3

3659

23053.275

... More
6.7 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (P.NO. 13/6.7/PWDSR/23-24). Volume - 2 (Ground Floor)

1.3

8621

11208.015

... More
12.90 - Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall(PWD SR 2023-24 P.No. 110 I.No. 12.90 ) V-2

10.8

7070

76363.56

... More
12.11 - Providing Honne wood frames of doors, windows, clerestory windows,ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps),but including cost of materials, labour, usage charges complete as per specifications.(Page No. 99 / Item No. 12.11 PWD SR 23-24) V-2 (Ground Floor)

0.27

144977

39143.979

... More
13.2.2 - Providing and fixing brass bib cock of approved quality : 20 mm nominal bore (Page No. 117I.no. 13.2.2)

10

320

3202.5

... More
13.32.3 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes [P.No- 122, i.no 13.32.3] (PWD SR 2023-24) Volume-2 (Ground Floor)

60

500

30051

... More
14.47 - Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.(PWD SR 2023-24 Vol-2, P.No.138 I.No.14.47)

2

14922

29845.2

... More
14.1.1 - Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests(Page.131. No.14.1.1 of PWD SR 2023-24) V-2

1

5128

5128.2

... More
14.7.3 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps (Page.132. No.14.7.3 of PWD SR 2023-24) V-2

3

3009

9027.9

... More
10.14.11 - Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.6 Kg/m2: 110mm(weight of pipe -1.894 kg)[P.No- 120, i.no 10.14.11] (PWD SR 2023-24) Volume-5

20

375

7518

... More
12.15 - Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) (Page.100. No.12.15 of PWD SR 23-24) V-2 (Ground Floor)

3.68

7816

28763.616

... More
11.35.1.3 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion :Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. (Page.87. No.11.35.1.3 of PWD SR) V-2

1150.5

523

602804.475

... More
11.37.1 - Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Page.89. No.11.37.1 of PWD SR) V-2

14.64

1037

15187.536

... More
11.36.1 - Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge: Pre- laminated particle board with decorative lamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery complete as per specifications. (Page.89. No.11.36.1 of PWD SR 2023-24) V-2 (Ground Floor)

204.34

941

192457.629

... More
8.25 - Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge(P.No. 45/8.25/PWDSR/23-24). volume-2

316.28

143

45496.878

... More
9.22.5 - Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x1200mm (PWD SR 2023-24 P.No. 62 I.No.9.22.5) V-2 (Ground Floor)

139.06

2089

290565.87

... More
9.20.5 - Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x1200mm (PWD SR 2023-24 P.No. 62 I.No. 9.20.5 V-2) (Ground Floor).

139.06

110

15331.365

... More
9.11 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (Page.60. No.9.11 of PWD SR) V-2

7.2

933

6720.84

... More
9.39 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (Page.65. No.9.39 of PWD SR 2023-24) V-2

39.06

1521

59427.837

... More
8.40 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. [P.No-48 ,I.No-8.40] (PWD SR 2023-24) Volume-2

21.6

120

2608.2

... More
1.2.2 - 1.2 Concealed Conduit System Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick (P.NO. 2 i.no 1.2.2 /electrical items/23-24).

250

78

19500

... More
1.5.2 - Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box (Pg.No-3 I.No-1.5.2 PWD Elec SR 23-23 V-6)

30

56

1680

... More
3.3.3 - Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.Cwall,including necessary rawlplugs,Machine/NF screws etc., complete.4-5 Way (Page No. 8 / Item No. 3.3.3 PWD Elect SR V-6) 23-24

4

137

548

... More
3.3.6 - Supplying and fixing surface/flush mounting un breakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall,including necessary rawl plugs,Machine/NF screws etc., complete. (P- 8, INo.- 3.3.6) (ELE SR 2023-24)

20

261

5220

... More
6.4.2 - Supplying of Ceiling Fan with Capacitor rating As per guide line of BEE 5star rating and IS:374/19 and also comply with IS:1709/1984 with latest amendment,Rated voltage 220V/50Hz,Rated power upto 35W+/-10%,Rated current As per IS:374/19,Rated power factor 0.9 lagging(min),Rated speed 350+/-10%RPM,Rated air delivery210+/-10% Cubic Meter Minimum,Rated service value 6.2CMM/W,Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet,Class Bmotorin sulation,BearingTwo ball bearings,Top 6202,Bottom 6201,as per IS specification,Motor winding.Temp rise Shall not exceed 75 deg Cover and ambient of 400Cbyre sistance method at 245V,Insulation resistance Shall not be less than Two Mega Ohms (2MOhms),Leakag ecurrent Should not exceed 210 Micro Amp,Power input,W& current,Air Delivery & Fan Speed as per IS:374/2019 with late stamendment,2 year manufacturer Warranty.(BLDC fans) 56" Sweep 5 Star (1400 mm) (Page No. 30/ Item No. 6.4.2 PWD Elect SR V-6) 23-24

12

3754

45048

... More
2.3.2 - Wiring for lighting / power circuit using one of FRLS PVC insulated 1100 v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694: confirming to latest amendments. 1.5 sqmm (PWD Electrical SR 2023-24 P.No.5, I.No.2.3.2 )

360

26

9360

... More
2.3.3 - Wiring for lighting / power circuit using one of FRLS PVC insulated 1100 v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694: confirming to latest amendments. 2.5 sqmm (PWD Electrical SR 2023-24 P.No.5, I.No.2.3.3)

540

42

22680

... More
2.3.4 - Wiring for lighting / power circuit using one of FRLS PVC insulated 1100 v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694: confirming to latest amendments. 4.00 sqmm (PWD Electrical SR 2023-24 P.No.5, I.No.2.3.4)

360

63

22680

... More
3.6.1 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch (Page No. 9 / Item No. 3.6.1 PWD Elect SR V-6) 23-24

120

102

12240

... More
3.6.3 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket (Page No. 9 / Item No. 3.6.3 PWD Elect SR V-6) 23-24

49

171

8379

... More
3.6.6 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.600W Dimmer (Page No. 9 / Item No. 3.6.6 PWD Elect SR V-6) 23-24

11

329

3619

... More
11.3.2 - Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. . LED light fitting 1 x 4' - 20/22 W (P.NO. 43/11.3.2/electrical items/23-24)

16

690

11040

... More
11.11.5 - Supplying & fixing of retro fit type-LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT6500 degree K,CRI70%.efficacy80 lumenper W,life25000 burning hours and Compliance to IS 10322/IEC 60598,LM79&LM80.The LED are driven by HF electronic driver integrated in the system,with PF0.95,power loss should5%of lamp Wage.,short circuit & open circuit protection to be integrated in the circuit,TH Dless than 20%,Life as per LM79.The operating input voltage should be between130 to 275V.BIS Approved and Tested by NABL/CPRI accreditedla boratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12W, 6500K (P.No. 47/I.No. 11.11.5 of PWD Elect SR 2023-24) V-6

6

269

1614

... More
9.1.1 - Supplying, erecting, testing and commissioning of voltage stabilizer 3kVA Capacity suitable for 170 to 270 v input and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete.(PWD Electrical SR 2023-24 P.No.38, I.No.9.1.1)

1

3995

3995

... More
6.8.5 - Supplying of 1.5 Tone Capacity Invertor type split Air conditioners with 5 Star suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. (PWD Electrical SR 2023-24 P.No.31, I.No.6.8.5)

1

56355

56355

... More
11.34A - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (Page No. 86 / Item No. 11.34A PWD SR 23-24 ) V-2

7.56

176

1333.584



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.