Rural Development And Panchayat Raj Department Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Rural Development And Panchayat Raj Department - RDPR Tender

Civil And Construction
Paints and Enamels
Opening Date26 Sep 2024
Closing Date14 Oct 2024
Tender Amount₹ 13,05,551.9 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2.3.3 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (P, 5, I.No. 2.3]B) 2.5 Sqmm (P, 6, I.No. 2.3.3]

250

42

10500

... More
2.3.4 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (P, 5, I.No. 2.3]C) 4 .00 Sqmm (P, 6, I.No. 2.3.4]

460

63

28980

... More
2.1 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (P, 5, I.No. 2.1]

6

285

1710

... More
2.1.2 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (P, 5, I.No. 2.1]B) Medium point above 3Mtr (P, 5, I.No. 2.1.2

6

394

2364

... More
2.1.3 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (P, 5, I.No. 2.1]C) Long point above 6Mtr upto 10Mtr (P, 5, I.No. 2.1.3]

6

570

3420

... More
3.4 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P, 9, I.No. Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in rick/Stone/C.C wall (P, 9, I.No

4

177

708

... More
3.3.5 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P, 9, I.No. b) 8 Way (P, 9, I.No. 3.3.5]

8

261

2088

... More
3.3.6 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (P, 9, I.No. 3.4], C) 10-12 Way (P, 9, I.No. 3.3.6]

6

319

1914

... More
3.5 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (P, 9, I.No. 3.5

4

175

700

... More
3.5.6 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (P, 9, I.No. 3.5],B) 8 Module (P, 9, I.No. 3.5.6]

8

284

2272

... More
3.5.6 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (P, 9, I.No. 3.5]c) 10 to 12 Module (P, 9, I.No. 3.5.6]

6

344

2064

... More
3.6.1 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P, 10, I.No. 3.6]A) 6Amps one way Switch (P, 10, I.No. 3.6.1]

90

102

9180

... More
3.6.3 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P, 10, I.No. 3.6]B) 6Amps 3way socket (P, 10, I.No. 3.6.3]

25

171

4275

... More
3.6.4 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P, 10, I.No. 3.6]C) Stepped fan regulator (P, 10, I.No. 3.6.4]

10

357

3570

... More
3.6.10 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P, 10, I.No. 3.6]D) 6/16A Universal Socket (P, 10, I.No. 3.6.10]

8

236

1888

... More
3.6.11 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (P, 10, I.No. 3.6]E) 32Amps DP switch (P, 10, I.No. 3.6.11]

8

326

2608

... More
12.46 - Supplying & Fixing of 70-150 W lamp holder 2 Pin(P, 52, I.No.12.46]

20

63

1260

... More
3.4 - supplying and flush mounting powder coted galvanizied metal box suitable for mounting swich plates the box should be fmily flush mounted after due grove cutting in brick stone c c wall 8 awy

4

261

1044

... More
3.5.6 - supplying and flush mounting powder coted galvanizied metal box suitable for mounting swich plates the box should be fmily flush mounted after due grove cutting in brick stone c c wall 4 way

3

177

531

... More
5.18.1 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. [p, 27 I.No 5.17], 6-32 Amps SP [p, 27 I.No. 5.18.1]

4

415

1660

... More
11.11.5 - Supplying & fixing of retrofit type LED bulb.W with OPA Lacrylic diffuser comprising of LED source with CCT 6500 degree K,CRI70 efficacy 80 lumenper W 25000 burning hour sand Compliance to IS10322IEC60598 ,LM79 LM80. The LED are drivenby HF electronic driver integrate dinthe system, with PF0.95, power loss should 5of lamp Wage. ,short circuit & open circuit protecti on tobeintegrate dinthe circuit ,THD lessthan20, Life asper LM79. The operating input voltage should bebetween 130to275V. BISA pprovedand Tested by NABCPRI accredited laboratory with 2years Warranty againstany manufacturing defect working under standard electrical condition.12W6500K [p, 47 I.No. 11.11.5supplying & fixing of retrofit type LED bulb with OPA Lacrylic diffuser comprising of LED source with CCT 6500 degree K CRI70 efficacy 80 lumenper W ife25000 burning hour sand Compliance to IS10322IEC60598 LM79 & LM80.The LED are drivenby HF electronic driver integrate dinthe system with PF0.95, power loss should 5of lamp Wage. ,short circuit & open circuit protecti on tobeintegrate dinthe circuit ,THD lessthan20, Life asper LM79. The operating input voltage should bebetwe 130to275V BISA pprovedan Tested by NABLCPRI accredited laboratory with 2years Warranty againstan manufacturing defect working under standard electrical condition.12W6500K 47 I.No. 11.11.5

15

269

4035

... More
11.14.2 - Supplyingandfixingofslimboxfitting,madeoutofCRCASheetmetalbodywithlockingtypeholdercompletelywired.ExcludingBallast & Fluorescent Tube. 1 x 4' Tube light fitting.[p, 47 I.No. 11.14.2]

15

361

5415

... More
11.8.2 - SupplyofLEDStreetlightluminairewithpressurediecastaluminiumhousingbodyforoptimalthermaldissipation.LampcompartmentcomprisingofantiglarecleardiffuserwithInjectionmouldedpolycarbonatematerial,deliveringsuperiorlightoutputRatedlifeBurningHrs50000hrLumenMaintenanceof70,maximumlightintensityshouldbebetween60degreesto70degrees.CCT5500K,IP66opticalandelectricalcompartment&impactresistanceofcompleteluminaireK08.PowerFactor0.9withmains,SurgeProtectionMin5KValongwithOvervoltage/Overload,shortcircuitmisswiringprotection.Compatibleforpolemountingwithouterdiaof40mmto50mm.UniversalVoltagedrivertooperatewidevoltagerangefrom100Vto270V50/60Hzapplication.CompliancetoIS10322/IEC60598,LM79&LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with singlescrewtoensureeaseofmaintenanceatthesightsitelocationwithminimizedminimaltools.LEDLightfixturewith.WSystemPowerconsumption.LEDEfficiency1301m/w,nominalCRI75.LuminairemanufacturershouldhaveinusefacilityaccreditedbyNABL/CPRI&anyGovernmentcertifiedagency&Design&DevelopmentfacilitycertifiedbyISO90012008.Housingwithsupplierwordmark/nameshallbeEngraved/Embossingonthediecasthousing/Bodypart.Warrantyof2YearsagainstanymanufacturingdefectworkingunderstandardelectricalconditionsasmentionedaboveshouldbegivenbyLEDmanufacturer&Cree/Nichia/Lumileds/Osram make LED Source. LED Streetlight 40W [p, 46 I.No. 11.8.2]

6

4024

24144

... More
13.4.1 - SupplyingandfixingtelescopicM.S.bracketfabricatedbyusing0.5mlength4"diatelescopicM.S.pipe,with2"dia1.5mlongM.S.Bracketandareweldedwithsuitableangle,using6mmthickM.S.sheet,gripbolts&nuts,asrequired,suitablefor9to12ms.M.S.tubularpole,withnecessarytwocoatsofpainting,withallotheraccessories.Single bracket 1.5 m. Length [p, 46 I.No. 13.4.1]

6

1461

8766

... More
14.5 - Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. [p, 79 I.No 14.5]

15

162

2430

... More
13.11 - Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. [p, 46 I.No 13.11]

10

315

3150

... More
6.3.1 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS-3741979 and with double ball bearing system.48" Sweep (1200mm) Regular model . [p, 22 I.No 6.3.1]

10

2984

29840

... More
11.16.3 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. [ PWD SR Volume-2 Page No 83 Item No 11.16.3 ]

373.26

128

47814.606

... More
19.2.1 - Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge.[ PWD SR Volume-2 Page No 163 Item No 19.2.1 ]

29.24

1746

51057.426

... More
2.1.4 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & form work shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates [ PWD SR Page No 15. Item No. 2.1.4 ]

10.12

6527

66061.842

... More
9.12.2 - Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less that 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm [ PWD SR Page No60 Item No 9.12.2 ]

406.84

1202

489123.39

... More
3.3 - Scarifying Existing Granular Surface to a Depth of 50 mm by Manual Means[ PWD SR Volume-3 Page No 15 Item No 3.3 ]

196.75

52

10329.375

... More
4.27 - Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.[ PWD SR Volume-3 Page No 24 Item No 4.27]

29.51

2272

67052.622

... More
20.28 - Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 m3 capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant , curing of concrete slabs for 14- days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work.[ PWD SR Volume-3 Page No 137 Item No 20.28 ]

29.5

6692

197434.65



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.