Rural Development And Panchayat Raj Department Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Rural Development And Panchayat Raj Department - RDPR Tender

Works
Electrical and Electronics
Electrical Works
Opening Date30 Oct 2024
Closing Date6 Nov 2024
Tender Amount₹ 6,76,250.62 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Code04 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete..( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )250 A 4 x 30 x 10 mm Aluminium Strips

6

3847

23083.2

... More
Code05 - Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution).( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )400 A

1

36895

36895.04

... More
Code06 - Supplying and fixing HRC fuse units base on existing switch / panel board..( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )32 to 63 A

64

685

43868.16

... More
Code07 - Supplying and fixing HRC fuse units base on existing switch / panel board..( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )100 to 300 A

8

1029

8234.24

... More
Code08 - Supplying and fixing HRC fuse link on existing switch fuse base with W loss as per IS-13703.( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) ) upto 63 A

64

325

20858.88

... More
Code09 - Supplying and fixing HRC fuse link on existing switch fuse base with W loss as per IS-13703.( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )Above 63 A to 200 A

8

426

3413.76

... More
Code10 - Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling.( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )300A to 400A TPDT/COS

1

667

667.52

... More
Code11 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism..( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) ) Four Pole 250 A 25 kA

1

23957

23957.92

... More
Code12 - Supplying and fixing of Shunt trip suitable for MCCB.CBCT..( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )

1

1907

1907.36

... More
Code13 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board..( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )

1

10365

10365.6

... More
Code14 - Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy..( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )

1

10432

10432.8

... More
Code15 - Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound..( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )

3

629

1888.32

... More
Code16 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C..( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )

3

576

1730.4

... More
Code17 - Supplying of 1.1 KV ,XLPE or Heat reisistant PVC insulated , PVC extrusted inner seath Armored , LTUG Cable as per IS-1554 ( Part-1) or IS-7098 Part-1 , Armouring strip thickness and resistively as per IS-3975,.(COMMON Electrical SR of 2023-24,BESCOM-Standard Stock Materials( 11 KV System)185 Sqmm, 3.5 Core, (28 GI Strips -4 x 0.8 mm)Materials cost Rs.

0.1

774164

77416.416

... More
Code18 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock)in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work...( COMMON Electrical SR of 2023-24, PWD CIVIL SR CHAPTER-1 )In all kinds of soils. Depth upto 1.50m Ic, 40 x 0.60 x 0.60 = 14.4 cmt

14.4

542

7805.952

... More
Code19 - Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications..( COMMON Electrical SR of 2023-24, PWD CIVIL SR CHAPTER-1 )Qty as above item, Labour charges Rs,

14.4

179

2580.48

... More
Code20 - Laying of cable in existing Trench / GI Pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff,,.LT Cable -120 to 240 Sqmm,Labour charges Rs,

0.1

36151

3615.136

... More
Code21 - Supplying of Cable gland ,..( COMMON Electrical SR of 2023-24, BESCOM-Standard Stock Materials( 11 KV System )45mm Materials cost Rs.

4

220

882.56

... More
Code22 - Supplying of Haevy Duty Copper Terminal Long Barrel,..( COMMON Electrical SR of 2023-24, BESCOM-Standard Stock Materials( 11 KV System ) )95 Sqmm Copper Terminal, Apprx Wt: 58 GmMaterials cost Rs.

4

144

577.92

... More
Code23 - Supplying of Haevy Duty Copper Terminal Long Barrel,..( COMMON Electrical SR of 2023-24, BESCOM-Standard Stock Materials( 11 KV System ) )185 Sqmm Copper Terminal, Apprx Wt: 158 Gm Materials cost Rs.

12

306

3682.56

... More
Code24 - Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts..( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )

5

4766

23833.6

... More
Code25 - GI/Copper strips for grounding connections, using necessary fixing materials as required..( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )GI/Copper strips 25 x 3 mm GI strip

40

91

3673.6

... More
Code26 - GI/Copper strips for grounding connections, using necessary fixing materials as required..( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )25 x 3 mm Copper strip

20

638

12768

... More
Code27 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. ( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )6-32 A DP

6

827

4966.08

... More
Code28 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. ( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )50-63 A TPN

1

3458

3458.56

... More
Code29 - Open Conduit System Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.( COMMON Electrical SR 2023-24 PART- III Utilization ( PWD Electrical) 19/20 mm dia 2 mm thick

90

77

6955.2

... More
Code30 - Open Conduit System Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.( COMMON Electrical SR 2023-24 PART- III Utilization ( PWD Electrical)25 mm dia 2 mm thick

120

90

10886.4

... More
Code31 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )1-2 Way

5

154

772.8

... More
Code32 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )4-5Way

3

198

594.72

... More
Code33 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )8Way

5

292

1461.6

... More
Code34 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )10-12Way

4

357

1429.12

... More
Code35 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 1-2 Module

5

153

767.2

... More
Code36 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 4 Module

3

196

588

... More
Code37 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )8 Module

5

318

1590.4

... More
Code38 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )10-12 Module

4

385

1541.12

... More
Code39 - Wires and Cables-Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )Short point upto 3Mtr from tapping point to out let via switch box

4

301

1205.12

... More
Code40 - Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch box

5

424

2122.4

... More
Code41 - Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch box

4

621

2486.4

... More
Code42 - Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6Amps one way Switch

30

114

3427.2

... More
Code43 - Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )6Amps 3way socket

10

191

1915.2

... More
Code44 - Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) Stepped Fan Regulator Two Module

4

399

1599.36

... More
Code45 - Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6Amps Bell push

2

198

396.48

... More
Code46 - Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 32Amps DP switch

6

365

2190.72

... More
Code47 - Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate.. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6/16Amps universal socket

6

264

1585.92

... More
Code48 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. ( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )1.5 mm2

900

29

26208

... More
Code49 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. ( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )2.5 mm2

1100

47

51744

... More
Code50 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. ( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )4.0 mm2

450

70

31752

... More
Code51 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. ( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )6.0 mm2

80

103

8243.2

... More
Code52 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V@ 50/60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. ( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )LED light fitting 1 x 4' - 20/22 W

15

772

11592

... More
Code53 - LED Street light. Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT more than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire more than IK08. Power Factor more than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency more than 1301m/w, nominal CRI more than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.. ( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )LED Streetlight 90 W

4

9923

39692.8

... More
Code54 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) ) 48" Sweep (1200 mm) Regular model

6

3342

20052.48

... More
Code55 - Supplying and Fixing........mm dia clampsss A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. ( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )Using 32mm dia G.I.Pipe

4

1450

5801.6

... More
Code56 - Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )On wall/ ceiling / Rafter / Girders

15

136

2049.6

... More
Code57 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.( Common Elecrical SR of 2023-24 - PWD-Part-III Utilization( PWD Electrical ) )

6

191

1149.12



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.