Rural Development And Panchayat Raj Department Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Rural Development And Panchayat Raj Department - RDPR Tender

Works
Civil And Construction
Building Construction
Opening Date30 Dec 2024
Closing Date8 Jan 2025
Tender Amount₹ 9,63,774.42 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (PWD SR, 2023-24, Volume-1 Item No. 2.1.2, p. No. 15).

1.678

6123

10275.4008

... More
code05 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates (PWD SR, 2023-24, Volume-1 Item No. 2.1.3, p. No. 15).

2.7402

6511

17841.57921

... More
code06 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (PWD SR, 2023-24, Volume-1 Item No. 2.1.6, p. No. 15).

0.2025

6797

1376.53425

... More
code07 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. 2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR, 2023-24, Volume-1 Item No. 2.5.1, p. No. 17).

2.9807

7249

21607.69044

... More
code08 - Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :5.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD SR, 2023-24, Volume-2 Item No. 5.1.1, p. No. 09).

6.3369

5891

37334.163195

... More
code09 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD SR, 2023-24, Volume-2 Item No. 5.4, p. No. 09).

4.3856

6708

29420.57832

... More
code10 - Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (PWD SR, 2023-24, Volume-1 Item No. 1.11, p. No. 07).

10.7996

454

4910.03814

... More
code11 - Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (PWD SR, 2023-24, Volume-1 Item No. 1.11, p. No. 07).

5.3998

454

2455.01907

... More
code12 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge (PWD SR, 2023-24, Volume-2 Item No. 6.1, p. No. 13).

10.3914

8631

89688.1734

... More
code13 - Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges completeas per specifications. (PWD SR, 2023-24, Volume-2 Item No. 12.12, p. No. 99).

0.1905

130412

24843.50505

... More
code14 - Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) (PWD SR, 2023-24, Volume-2 Item No. 12.21, p. No. 100).

2.52

6029

15193.332

... More
code15 - Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) (PWD SR, 2023-24, Volume-2 Item No. 12.15, p. No. 100).

5.76

7241

41713.056

... More
code16 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (PWD SR, 2023-24, Volume-2 Item No. 11.34A, p. No. 86).

161.28

176

28449.792

... More
code17 - Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 ,Volume-2, Item No. 8.3.2, P.No. 41).

10.212

349

3570.6258

... More
code18 - Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 ,Volume-2, Item No. 8.1.1, P.No. 14).

17.9994

267

4819.33935

... More
code19 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 , Volume-2 Item No. 8.2.1,P.No. 41).

188.14

309

58276.365

... More
code20 - Distempering with dry distemper of approved brand and manufacture (two coats) of required shade on new work, over and including water thinnable priming coat to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 , Volume-2 Item No. 8.24,P.No. 45).

216.3513

113

24534.23742

... More
code21 - Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 ,Volume-2, Item No. 8.33.2, P.No. 46).

18.63

144

2699.487

... More
code22 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (PWD SR, 2023-24, Volume-1 Item No. 2.1.2, p. No. 15).

1.3499

6123

8266.24764

... More
code23 - Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).9.21.1 Size of Tile 500x500 mm (PWD SR 2023-24 ,Volume-2, Item No. 9.21.1, P.No. 62).

17.9994

1234

22225.65912

... More
code24 - Providing structural steel for sub-structure complete as per drawing and technical specification (PWD SR, 2023-24, Volume-3 Item No. 12.12, p. No. 118).

0.6524

176128

114905.93982

... More
code25 - Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including including cost of materials, labour, curing, polishing complete as per specifications (PWD SR 2023-24 ,Volume-2, Item No. 9.35, P.No. 64).

8.3999

1717

14429.34822

... More
code26 - Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge & MoRTH specification 804 (PWD SR, 2023-24, Volume-3 Item No. 8.54, p. No.78)

1

9450

9450

... More
code27 - Open Conduit System: Supplying heavy gauge PVC conduit pipe........... dia. confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wook boxes in case of RCC ceiling and RCC wall stone structure or raw plugs in case of brick wall and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. (PWD DSR 2019-20, I. No.1.1, P.No.2) 25 mm dia. 2mm thick

8

175

1400

... More
code28 - Supplying heavy gauge PVC Conduit Pipe ....... dia .....mm thick suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG G fish wire run throughout the conduit wherever necessary (PWD DSR 2019-20, I. No. 1.3b, P.No.2)25 mm dia. 2mm thick

15

54

810

... More
code29 - Supplying heavy gauge PVC Conduit Pipe ....... dia .....mm thick suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG G fish wire run throughout the conduit wherever necessary (PWD DSR 2019-20, I. No. 1.3b, P.No.2)32 mm dia. 2.5 mm thick

10

81

810

... More
code30 - Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100v grade COPPER Conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm. cable confirming to GTP, with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block complete for each outlet. (PWD DSR 2019-20, 1.No.2.1, P.No.5)a) Short Point upto 3 Meters long from tapping point to out let via. switch. (PWD DSR 2019-20, I.No.2.1.1, P.No.5)

2

200

400

... More
code31 - Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100v grade COPPER Conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm. cable confirming to GTP, with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block complete for each outlet. (PWD DSR 2019-20, 1.No.2.1, P.No.5)b) Short Point upto 3 Meters long from tapping point to out let via. switch. (PWD DSR 2019-20, I. No.2.1.2, P.No.5

2

275

550

... More
code32 - Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100v grade COPPER Conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm. cable confirming to GTP, with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block complete for each outlet. (PWD DSR 2019-20, 1.No.2.1, P.No.5)c) Medium Point above 6 Mtrs to 10 mtrs. from tapping point to out let via. switch. (PWD DSR 2019-20, I.No.2.1.3), P.No.5

1

400

400

... More
code33 - Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood after due groove cutting, finishing with necessary cement plastering complete (PWD DSR 2019-20, 1.No.1.6, P.No.3)8"x6"x3"

2

64

128

... More
code34 - Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood after due groove cutting, finishing with necessary cement plastering complete (PWD DSR 2019-20, 1.No.1.6, P.No.3)4"x4"x3"

2

60

120

... More
code35 - Wiring for lighting / power circuit using of one of FRLS PVC insulated 1100v grade, multistand copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & Confirming to GTP of GROUP-A (PWD DSR 2019-20, I No.2.5, P.No.6)a) 1.5 sqmm. (PWD DSR 2019-20, 1, No. 2.3.2, P.No.5-6)

60

20

1230

... More
code36 - Wiring for lighting / power circuit using of one of FRLS PVC insulated 1100v grade, multistand copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & Confirming to GTP of GROUP-A (PWD DSR 2019-20, I No.2.5, P.No.6)b) 2.5 sqmm. (PWD DSR 2019-20, L.No.2.3.3, P.No.6)

60

35

2100

... More
code37 - Wiring for lighting / power circuit using of one of FRLS PVC insulated 1100v grade, multistand copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & Confirming to GTP of GROUP-A (PWD DSR 2019-20, I No.2.5, P.No.6)c) 4.0 sqmm. (PWD DSR 2019-20, 1.No.2.3.4, P.No.6)

60

45

2700

... More
code38 - Supplying and fixing Regular MCB distribution boards on wall board flush mounting using required clamps bolts, nuts etc. with provision for fixing suitable type capacity MCB's single phase 3 phase single door with powder coated painting made out of 14 SWG MS enclousea) 12 Way SP (PWD DSR 2019-20, I. No.5.18.8, P.No.28)

1

1800

1800

... More
code39 - Supplying and fixing Regular MCB distribution boards on wall board flush mounting using required clamps bolts, nuts etc. with provision for fixing suitable type capacity MCB's single phase 3 phase single door with powder coated painting made out of 14 SWG MS enclouseb) 4 Way SP (PWD DSR 2019-20,

2

1100

2200

... More
code40 - Supplying and fixing Miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with Short Circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (PWD DSR 2019-20, 1.No.5.17.1, P.No.27)a) 6-2 Amps SP

2

434

868

... More
code41 - Supplying and fixing Miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with Short Circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 (PWD DSR 2019-20, 1.No.5.17.1, P.No.27)b) 50-63 Amps DP

1

1355

1355

... More
code42 - LED Indoor Supply of 2' feet LED PVC Square Batten W with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power input: 220-240V @ 50Hz & Power factor 0.9 along with CE approved drivers. 5 years warranty against any manufacturing defect working under standard electrical condition (PWD DSR 2019-20, 1.No. 12.3.4, P.No.) LED Light Fitting 1x4' 20/22W

5

375

1875

... More
code43 - Supply capacitor type ceiling fan complete with down rod blades, shakle regulator canopies etc. for operation on 230 volts, 50 cycles, single phase AC supply confirming to ISS 374-1979 and with bouble ball bearing system - 48" Sweep (1200 mm) (PWD DSR 2019-20, I.No.7.3, P.No.46)

4

2090

8360

... More
code44 - Supply of 1440 rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz AC supply 12" Sweep 300mm (PWD DSR 2019-20, I.No.7.2.1, P.No.46)

4

2100

8400

... More
code45 - Supply and fixing PBBC Bakelite straight or slant batten holder and wiring with 60W 230 Volts Clamps PBBC Bakelite Straight etc. completed (PWD DSR 2019-20, 1. No.4.2, P.No.20)

8

88

704

... More
code46 - Supply, fixing and wiring Electronic Trivector Meter (ETC)5 to 20 amps single phase Class-1 Accurcy with Temple Proof Energy Meter et. completed (PWD DSR 2019-20, I.No.5.30, P.No.29)

1

1150

1150

... More
code47 - Supply and fixing of .... Mm dia: Class-A GI Pipe bracket up to 2 Mirs long bent at suitable angle and fixing to this bracket 1x40/2x40 watts flourescent tube street light fitting of all capacities to GI and CI or Rail or RCC pole / wall using suitable clamps and bolts and wiring using suitable capacity wires (PWD DSR 2019-20, I.No. 14.1, P. No.79) Using 32mm dia. Gt Pipe

1

835

835

... More
code48 - Fixing of all types and all capacities flourescent / false ceiling/ spot light/CFL/LED fittings Indoor on the wall / Ceiling/ rafters/ girders using 23/0.0076" twin twisted PVC insulated wires, required nos of round blocks and clamps if required On wall / ceiling/rafter/ girders (PWD DSR 2019-20, I.No. 14.7.1, P. No.79)

4

110

440

... More
code49 - Fixing of ceiling / wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board with supplying and fixing a 5 ampes ceiling rose necessary length of 23/0.0076' PVC insulated twin twisted copper wire and wiring - Fixing a Ceiling (PWD DSR 2019-20, I.No.14.8, P.No.80)

4

150

600

... More
code50 - Fixing One Exhaust Fan in the nitch already left in the wall with bolts and nuts and 5 amps ceiling rose with sufficient lenght of of 23/0.0076' PVC insulated twin core wire - Exhaust Fan (PWD DSR 2019-20, 1. No. 14.12, P.No.80)

1

400

400

... More
code51 - Fixing halogen / metal hallide / SVL/IL/ LED flood light fitting over existing pole wall including clamps bolts nuts and wiring using suitable capacity wire etc. completed Fixing Halogen / Metal Halide SVL Flood Light (PWD DSR 2019-20, 1. No. 14.5, P. No.79)

3

175

525

... More
code52 - Supplying and fixing hylum plastic sheet 3mm thick with necessary nitiches for fixing switches, regulators etc, and fixing on existing wood or metal box using N.F.screws etc. completed (PWD DSR 2019-20, L.No.3.9, P.No. 10)

500

-

120

... More
code53 - Supplying and fixing angle iron frame work fabricated out of M.S angle iron..and M.S flat... with bolts, washers etc, and painted with 2 coats of red oxide and then two coats of approved paint - 40x40x6mm etc. completed (PWD DSR 2019-20, 1.No.5.41.1, P.No.30)

1

255

255

... More
code54 - Supplying, fixing, wiring, earth electrode for grounding conduits I.C cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick G.I pipe 2.5mtr long buried in a pit..The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. using 12mm dia bolts, nuts, washers and check nuts etc. the pipe shall have 16 through holes of 12mm dia etc. completed (PWD DSR 2019-20, 1.No.6, P.No.40)

1

2999

2999.7

... More
code55 - Supplying and running GI/ Copper conductor for grounding and along with other wires in conduit system of wiring using necessary suitable size clamps, nailsm guttas spacers etc-8 SWG Gl wire etc. completed (PWD DSR 2019-20, 1.No.6.18.1, P.No.43)

8

14

112

... More
code56 - Supplying and fixing of class A (medium duty) GI Pipe of wall thickness not less than 3.25mm on pole wall drain crossing with necessary clamping arrangments for UG cale of 1.1 k 40mm etc. completed (PWD DSR 2019-20, I.No.6.9.1, P.No.41)

8

355

2840

... More
code57 - Labour charges for logging UG cable 6 sqmm to 16 sqmm (PWD DSR 2019-20, 1.No.7.2.1, P.No.46)

8

11

95.04

... More
code58 - Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armored UG LT cable Part- 1. Armoring strip thickness in average +5% and resistivity 14 Ohms/Km (Max) as per IS-3975- 2Core 10 Sqm. (PWD DSR 2019-20,

8

95

760

... More
code59 - Supply and laying double walled corrugated (DWC) HDPE Pipe including all neceassary connecting sockets couplings/ Teels /Bends/ End caps of same materials in existing trench -63mm dia OD50mm ID etc. completed 2 core 10 sqmm (PWD DSR 2019- 20, 1.No.7.20, P.No.63)

8

206

1648

... More
code60 - Supplying and fixing cut out 16 amps (PWD DSR 2019-20, 1.No.5.7, P.No.24)

2

117

234

... More
code61 - Supplying and fixing of 4 pole powder contractor 40 amps (PWD DSR 2019-20, .5.13.2, P.No.26)

1

1840

1840

... More
code62 - Supplying of TPST with rewireable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour (PWD DSR 2019-20, 1.No.5.5.1, P.No.24)

1

1800

1800

... More
code63 - Supplying 6A flush type socket and 6 amps flush type SP switch either surface/ flush mounting in exisiting gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654-9-6 amps 3/5 way etc. completed (PWD DSR 2019-20, 1.No.3.1.2, P.No.9)

8

132

1056

... More
code64 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavatio etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: 10.1.1 PVC pipes 25mm dia, 10 kg/sqcm & class 5 (PWD SR 2023-24 ,Volume-5, Item No. 10.1.1, P.No. 113).

25

50

1260

... More
code65 - Supplying of special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete. 10.8.1 25mm dia PVC couplers (PWD SR 2023-24 ,Volume-5, Item No. 10.8.1, P.No. 116).

10

12

126

... More
code66 - Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 10.9.1 25 mm dia PVC Elbows (PWD SR 2023-24 ,Volume-5, Item No. 10.9.1, P.No. 116).

10

16

168

... More
code67 - Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 10.11.1 25 mm dia PVC BEND (PWD SR 2023-24 ,Volume-5, Item No. 10.11.1, P.No. 118).

8

25

201.6

... More
code68 - Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 25 mm dia PVC Tee (PWD SR 2023-24 ,Volume-5, Item No. 10.10.1, P.No. 117).

8

22

176.4

... More
code69 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(PWD SR 2023-24 , Volume-2 Item No. 13.34,P.No. 123).

1000

9

9450

... More
code70 - Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. (PWD SR 2023-24 ,Volume-2, Item No. 14.8, P.No. 206).

1

1494

1494.15

... More
code71 - Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work 1.16.1 In Hard Rock ( requiring blasting) Depth upto 1.50m (PWD SR 2023-24 Volume-1 Item No. 1.16.1. p.No.09).

20.25

581

11779.425

... More
code72 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (PWD SR, 2023-24, Volume-1 Item No. 2.1.2, p. No. 15).

2.6999

6123

16533.10764

... More
code73 - Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :5.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD SR, 2023-24, Volume-2 Item No. 5.1.1, p. No. 09).

13.5

5891

79535.925

... More
code74 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD SR, 2023-24, Volume-2 Item No. 5.4, p. No. 09).

6.075

6708

40753.83375

... More
code75 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge (PWD SR, 2023-24, Volume-2 Item No. 6.1, p. No. 13).

8.28

8631

71464.68

... More
code76 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (PWD SR, 2023-24, Volume-1 Item No. 2.1.2, p. No. 15).

1.0125

6123

6200.145

... More
code77 - Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR, 2023-24, Volume21 Item No. 8.3.2, p. No. 41).

72

349

25174.8

... More
code78 - Distempering with dry distemper of approved brand and manufacture (two coats) of required shade on new work, over and including water thinnable priming coat to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 , Volume-2 Item No. 8.24,P.No. 45).

72

113

8164.8

... More
code79 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (PWD SR, 2023-24, Volume-1 Item No. 2.1.2, p. No. 15).

1.0125

6123

6200.145

... More
code80 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed required Fixed to steel windows by welding (PWD SR 2023-24 , Volume-2 Item No.11.34A,P.No. 86).

53.9999

176

9525.58236



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.