Rajiv Gandhi University Of Health Sciences Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Rajiv Gandhi University Of Health Sciences Tender

Civil And Construction
Building Construction
Opening Date7 Mar 2024
Closing Date15 Apr 2024
Tender Amount₹ 39,36,02,177.2 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Man04 - Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work. In ordinary soft rock without blasting including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. : (ii). DEPTH: 3.00 to 4.50m

2621

486

1274199.15

... More
Man05 - Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work. In ordinary soft rock without blasting including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. : (iii). DEPTH: 4.50 to 6.00m

2043

510

1042869.78

... More
Man06 - Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work. In ordinary soft rock without blasting including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. : (iv). DEPTH: 6.00 to 6.30m

380

515

195821.6

... More
Man07 - Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery and all other appurtenaces required to complete the work including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. In Hard Rock ( requiring blasting) : (i). DEPTH : 0 1.50 mts DEPTH

390

581

226863

... More
Man08 - Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery and all other appurtenaces required to complete the work including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. In Hard Rock ( requiring blasting) : (ii). DEPTH : 1.50 3.00 mts DEPTH

350

654

228952.5

... More
Man09 - Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery and all other appurtenaces required to complete the work including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. In Hard Rock ( requiring blasting) : (ii). DEPTH: 3.00 to 4.50m

210

746

156775.5

... More
Man10 - Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery and all other appurtenaces required to complete the work including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. In Hard Rock (requiring blasting) : (iii). DEPTH: 4.50 to 6.00m

180

783

141098.4

... More
Man11 - Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery and all other appurtenaces required to complete the work including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. In Hard Rock (requiring blasting) : (iv). DEPTH: 6.00 to 6.30m

40

791

31653.6

... More
Man12 - Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Mechanical means GradingII (53 mm to 22.4 mm) Using Screening Crushable type such as Moorum or Gravel : (i). Ground Floor: (Level 02):

420

2272

954324

... More
Man13 - Wet Mix Macadam (Plant mix method): KSRRB Wet Mix Macadam (Plant mix method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver grader in subbase base course on well prepared surface and compacting with vibratory roller to achieve the desired density. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. : (ii). Ground Floor: (Level 02):

310

2686

832954.5

... More
Man14 - Disposal of debris : Loading and Unloading of Stone Boulder Stone aggregates Sand Kanker Moorum. Loading and Unloading of Stone Boulder Stone aggregates Sand Kankar Moorum. (Tipper 10 m3) Cost of Haulage Excluding Loading and Unloading Case 1: Surface Road. A. Taking output 10 t load and lead 10 km = 100 t.kmw including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. .10 KM

8604

137

1183480.2

... More
Man15 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m including with all labour, all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works.

7466

279

2085253.8

... More
Man16 - Providing and injecting chemical emulsion for Preconstructional AntiTermite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20percent E.C. Lindane 20percent E.C. at 3.19 l m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Plinth area of the building at ground floor only shall be measured)

1985

123

245941.5

... More
Man17 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately)including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates FOUNDATION

144

6723

968211.36

... More
Man18 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately)including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. PLINTH BEAM

23

6723

154644.87

... More
Man19 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately)including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Sub Base: Lower Basement 01: (Level 01):

289

6723

1943146.41

... More
Man20 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately)including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Flagging and Above Entry Steps

16

6723

107579.04

... More
Man21 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately)including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Below SSM:

3

6723

20171.07

... More
Man22 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately)including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. CILL:

1

6723

6723.69

... More
Man23 - READY MIX CONCRETE : Providing and laying in position Reinforced cement concrete for all Foundation works. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] RAFT SLAB

107

7369

788576.09

... More
Man24 - READY MIX CONCRETE : Providing and laying in position Reinforced cement concrete for all Foundation works. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 340 Kgs Cum]: RAFT SLAB Foundation : (M 25 GRADE)

867

7185

6229412.34

... More
Man25 - Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.[Cement 360 Kgs Cum]: RETAINING WALL (M 30 GRADE): SUB STRUCTURE : (a). UP TO 1.40m LVL

202

7787

1572976.02

... More
Man26 - Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.[Cement 360 Kgs Cum]: For COLUMNS : (M 30 GRADE): SUB STRUCTURE FLOOR:

52

12034

625792.44

... More
Man27 - Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : RETAINING WALL (M 30 GRADE): LOWER BASEMENT 01: LEVEL 01

390

7628

2975224.2

... More
Man28 - Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 340 Kgs Cum] : RETAINING WALL (M 25 GRADE): Collection Sump

37

7484

276922.8

... More
Man29 - Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : COLUMNS: (M 30 GRADE): LOWER BASEMENT 01: LEVEL 01

54

11789

636656.22

... More
Man30 - Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The Cost of formwork included but steel reinforcement cost shall be paid separately but formwork cost included). [Cement 340 Kgs Cum] M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. COLUMNS M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

1

11309

11309.76

... More
Man31 - Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : For PLINTH Beams : Regular (M 30 GRADE): Lower Basement 01(Level 01):

32

10402

332892.16

... More
Man32 - Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately but formwork cost included) PLINTH BEAM: M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

1

10206

10206

... More
Man33 - Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : For Beams : Regular (M 30 GRADE): Lower Basement 01 (Level 01):

196

11096

2174894.4

... More
Man34 - Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : For Lintels: (M 30 GRADE): Lower Basement 01 (Level 01):

3

11096

33289.2

... More
Man35 - Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : For Slabs (M 30 GRADE): Lower Basement 01 (Level 01):

378

10402

3932288.64

... More
Man36 - Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 340 Kgs Cum] : For Slabs (M 25 GRADE): Lower Basement 01 (Level 01):

4

10206

40824

... More
Man37 - Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : for CILL (M 30 GRADE): Lower Basement 01(Level 01):

1

10402

10402.88

... More
Man38 - Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : for Staircase (M 30 GRADE): Lower Basement 01 (Level 01):

10

10402

104028.8

... More
Man39 - Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : for Ramp Beam (M 30 GRADE): Lower Basement 01:

22

11096

244120.8

... More
Man40 - Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : for Ramp Slab (M 30 GRADE) : Lower Basement 01:

46

10402

478532.48

... More
Man41 - Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : for Ramp Parapet Wall (M 30 GRADE) : Lower Basement 01:

20

7628

152575.6

... More
Man42 - Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : for Grade Slab (M 30GRADE): Lower Basement 01: (Level 01):

270

7143

1928693.7

... More
Man43 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]: RETAINING WALL (M 30 GRADE): GROUND FLOOR: Level 02

15

8093

121396.35

... More
Man44 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]: RETAINING WALL (M 30 GRADE): FIRST FLOOR: Level 03

15

8174

122610.3

... More
Man45 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]: RETAINING WALL (M 30 GRADE): SECOND FLOOR: Level 04

80

8255

660460.8

... More
Man46 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]: RETAINING WALL (M 30 GRADE): THIRD FLOOR: Level 05

15

8338

125074.8

... More
Man47 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]: RETAINING WALL (M 30 GRADE): FOURTH FLOOR: Level 06

15

8421

126325.5

... More
Man48 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]: RETAINING WALL (M 30 GRADE): FIFTH FLOOR: Level 07

5

8505

42529.6

... More
Man49 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]: RETAINING WALL (M 30 GRADE): SIXTH FLOOR: Level 07

25

8590

214774.5

... More
Man50 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For COLUMNS : (M 30 GRADE) : GROUND FLOOR: LEVEL 02

60

12507

750450

... More
Man51 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 320 Kgs Cum]. . M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates : For COLUMNS : GROUND FLOOR

2

12214

24429.52

... More
Man52 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For COLUMNS : (M 30 GRADE) : First FLOOR: LEVEL 03:

60

12632

757954.8

... More
Man53 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For COLUMNS : (M 30 GRADE) : SECOND Floor: Level 04:

60

12758

765534.6

... More
Man54 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For COLUMNS : (M 30 GRADE) : THIRD Floor: Level 05:

60

12886

773190

... More
Man55 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For COLUMNS : (M 30 GRADE) : Fourth Floor: Level 06: UP TO 3.50m LVL

44

13015

572676.28

... More
Man56 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For COLUMNS : (M 30 GRADE) : Fourth Floor: Level 06: ABOVE 3.50m Up to 7.00 LVL

22

13145

289201.44

... More
Man57 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For COLUMNS : (M 30 GRADE) : Fourth Floor: Level 06: ABOVE 7.00m Up to 10.50 LVL

18

13276

238985.64

... More
Man58 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For COLUMNS : (M 30 GRADE) : Fifth Floor: Level 07:

30

13145

394365.6

... More
Man59 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For COLUMNS : (M 30 GRADE) : SIXTH Floor: Level 08:

14

13276

185877.72

... More
Man60 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Beams : Regular (M 30 GRADE): Ground Floor (Level 02):

100

11771

1177176

... More
Man61 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Beams : Regular (M 30 GRADE): First Floor (Level 03):

115

11889

1367290.2

... More
Man62 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Beams : Regular (M 30 GRADE): Second Floor (Level 04):

130

12008

1561088.1

... More
Man63 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Beams : Regular (M 30 GRADE): Third Floor (Level 05):

135

12128

1637340.75

... More
Man64 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Beams : Regular (M 30 GRADE): Fourth Floor (Level 06):

55

12249

673735.15

... More
Man65 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Beams : Regular (M 30 GRADE): Fifth Floor (Level 08):

5

12372

61861.15

... More
Man66 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Beams : Regular (M 30 GRADE): Sixth Floor (Level 09):

5

12495

62479.75

... More
Man67 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately but cost of formwork included) M 20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 320 Kgs Cum]. . M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates :: GROUND FLOOR: REGULAR BEAMS ::

1

11496

11496.24

... More
Man68 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Lintels: (M 30 GRADE): Ground Floor (Level 02):

4

11771

47087.04

... More
Man69 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M 20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 320 Kgs Cum]. . M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates :: GROUND FLOOR: : LINTELS : GROUND FLOOR

1

11496

11496.24

... More
Man70 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Lintels: (M 30 GRADE): .First Floor (Level 03):

4

11889

47557.92

... More
Man71 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Lintels: (M 30 GRADE): Second Floor (Level 04):

6

12008

72050.22

... More
Man72 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Lintels: (M 30 GRADE): Third Floor (Level 05):

6

12128

72770.7

... More
Man73 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Lintels: (M 30 GRADE): Fourth Floor (Level 06):

6

12249

73498.38

... More
Man74 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Lintels: (M 30 GRADE): Fifth Floor (Level 07):

6

12372

74233.38

... More
Man75 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Slabs (M 30 GRADE): Ground Floor : (Level 02):

330

11036

3641889.9

... More
Man76 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M 20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 320 Kgs Cum]. . M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates :: GROUND FLOOR: : SLABS : GROUND FLOOR :

2

10777

21555.46

... More
Man77 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Slabs (M 30 GRADE): First Floor : (Level 03):

365

11146

4068432.35

... More
Man78 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Slabs (M 30 GRADE): Second Floor (Level 04):

330

11257

3715090.5

... More
Man79 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Slabs (M 30 GRADE): Third Floor (Level 05):

360

11370

4093354.8

... More
Man80 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Slabs (M 30 GRADE): Fourth Floor (Level 06):

400

11484

4593652

... More
Man81 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Slabs (M 30 GRADE): Fifth Floor (Level 07):

25

11598

289974.25

... More
Man82 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Slabs (M 30 GRADE): Sixth Floor (Level 08):

30

11714

351448.8

... More
Man83 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : SLOPED SLAB: Second Floor (Level 04):

70

10882

761781.3

... More
Man84 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M 25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 320 Kgs Cum]. . M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates :: GROUND FLOOR: CHAJJA : GROUND FLOOR :

2

10418

20836.94

... More
Man85 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for CILL (M 30 GRADE): Ground Floor (Level 02):

1

11036

11036.03

... More
Man86 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for CILL (M 30 GRADE): First Floor (Level 03):

1

11146

11146.39

... More
Man87 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for CILL (M 30 GRADE): Second Floor (Level 04):

69

11257

776791.65

... More
Man88 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for CILL (M 30 GRADE): Third Floor (Level 05):

1

11370

11370.43

... More
Man89 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for CILL (M 30 GRADE): Fourth Floor (Level 06):

1

11484

11484.13

... More
Man90 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for CILL (M 30 GRADE): Fifth Floor (Level 07):

1

11598

11598.97

... More
Man91 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : COPING: GROUND FLOOR:

1

11036

11036.03

... More
Man92 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : COPING: First FLOOR:

1

11146

11146.39

... More
Man93 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : COPING: Second FLOOR:

3

11257

33773.55

... More
Man94 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : COPING: Third FLOOR:

2

11370

22740.86

... More
Man95 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : COPING: Fourth FLOOR:

4

11484

45936.52

... More
Man96 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : COPING: Fifth FLOOR:

6

11598

69593.82

... More
Man97 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for Staircase (M 30 GRADE): Ground Floor: (Level 02)

10

11036

110360.3

... More
Man98 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for Staircase (M 30 GRADE): First Floor: (Level 03)

10

11146

111463.9

... More
Man99 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for Staircase (M 30 GRADE): Second Floor: (Level 04)

10

11257

112578.5

... More
Man100 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for Staircase (M 30 GRADE): Third Floor: (Level 05)

10

11370

113704.3

... More
Man101 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all heights.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for Staircase (M 30 GRADE): Fourth Floor: (Level 06)

12

11484

137809.56

... More
Man102 - PLAIN CEMENT CONCRETE : Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates DUMMY RETAINING WALL: FIFTH FLOOR: Level 06

5

7546

37734.6

... More
Man103 - PLAIN CEMENT CONCRETE : Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates DUMMY RETAINING WALL: For COLUMNS : Fifth Floor: Level 07

8

11663

93307.36

... More
Man104 - STEEL: Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (The laps and wastages shall not be measured separately).: Sub Structure Floor :

90.7

93929

8519437.395

... More
Man105 - STEEL: Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification at all heights. (The laps and wastages shall not be measured separately).:Lower Basement 01 (Level 01)

117.5

93929

11036757.375

... More
Man106 - STEEL: Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification at all heights. (The laps and wastages shall not be measured separately).: Ground Floor: (Level 02) :

91

93929

8547616.35

... More
Man107 - STEEL: Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification at all heights. (The laps and wastages shall not be measured separately).: First Floor: (Level 03):

127

94869

12048382.05

... More
Man108 - STEEL: Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification at all heights. (The laps and wastages shall not be measured separately).: Second Floor: (Level 04):

97

95817

9294330.48

... More
Man109 - STEEL: Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification at all heights. (The laps and wastages shall not be measured separately).: Third Floor: (Level 05):

81

96776

7838857.62

... More
Man110 - STEEL: Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification at all heights. (The laps and wastages shall not be measured separately).: Fourth Floor: (Level 06):

71

97743

6939808.38

... More
Man111 - STEEL: Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification at all heights. (The laps and wastages shall not be measured separately).: Fifth Floor: (Level 07):

13

98721

1283375.86

... More
Man112 - STEEL: Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification at all heights. (The laps and wastages shall not be measured separately).: Sixth Floor: (Level 08):

11

99708

1096792.73

... More
Man113 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge (Note: Approval to be taken by submitting Shop drawings before executing the work) . CANOPY AREA: GROUND FLOOR:

11980

142

1710744

... More
Man114 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge (Note: Approval to be taken by submitting Shop drawings before executing the work). CANOPY AREA: Fourth Floor:

51330

148

7627638

... More
Man115 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings wooden frames with rawl plugs screws etc. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Weight of Grill 18 Kgs Sq.m)

270

192

51880.5

... More
Man116 - MASONRY WORKS: Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Cement Mortar 1:6.

15

6708

100626.75

... More
Man117 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with SOLID CONCRETE BLOCKS of Sizes 400 x 200 x 200mm: Basement Floor:

245

1375

336997.5

... More
Man118 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with SOLID CONCRETE BLOCKS of Sizes 400 x 200 x 200mm: Ground Floor: Level 02:

1455

1375

2001352.5

... More
Man119 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with SOLID CONCRETE BLOCKS of Sizes 400 x 200 x 200mm: First Floor: Level 03:

1295

1389

1799091.7

... More
Man120 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with SOLID CONCRETE BLOCKS of Sizes 400 x 200 x 200mm: Second Floor: Level 04:

1435

1403

2013520.25

... More
Man121 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with SOLID CONCRETE BLOCKS of Sizes 400 x 200 x 200mm: Third Floor: Level 05:

1360

1417

1927364.8

... More
Man122 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with SOLID CONCRETE BLOCKS of Sizes 400 x 200 x 200mm: Fourth Floor: Level 06:

1035

1431

1481447.25

... More
Man123 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with SOLID CONCRETE BLOCKS of Sizes 400 x 200 x 200mm: Fifth Floor: Level 06:

1850

1445

2674471

... More
Man124 - Providing and Constructing Load Bearing Wall with SOLID CONCRETE BLOCKS having block density not less than 1800 Kg Cu.m having a minimum average compressive strength of 5.00 N Sq.mm confirming to IS 2185 (Part I):2005 and constructed with CM 1:4, as per IS 2572:2005 including cost of all materials labour charges, scaffolding, curing, hire charges of machineries, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. with SOLID CONCRETE BLOCKS of Sizes 400 x 150 x 200mm: Ground Floor:

805

1292

1040502.75

... More
Man125 - Providing and Constructing Load Bearing Wall with SOLID CONCRETE BLOCKS having block density not less than 1800 Kg Cu.m having a minimum average compressive strength of 5.00 N Sq.mm confirming to IS 2185 (Part I):2005 and constructed with CM 1:4, as per IS 2572:2005 including cost of all materials labour charges, scaffolding, curing, hire charges of machineries, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. KBS No. 5.4 with SOLID CONCRETE BLOCKS of Sizes 400 x 150 x 200mm: First Floor:

410

1305

535246.8

... More
Man126 - Providing and Constructing Load Bearing Wall with SOLID CONCRETE BLOCKS having block density not less than 1800 Kg Cu.m having a minimum average compressive strength of 5.00 N Sq.mm confirming to IS 2185 (Part I):2005 and constructed with CM 1:4, as per IS 2572:2005 including cost of all materials labour charges, scaffolding, curing, hire charges of machineries, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. KBS No. 5.4 with SOLID CONCRETE BLOCKS of Sizes 400 x 150 x 200mm: Second Floor:

485

1318

639487.05

... More
Man127 - Providing and Constructing Load Bearing Wall with SOLID CONCRETE BLOCKS having block density not less than 1800 Kg Cu.m having a minimum average compressive strength of 5.00 N Sq.mm confirming to IS 2185 (Part I):2005 and constructed with CM 1:4, as per IS 2572:2005 including cost of all materials labour charges, scaffolding, curing, hire charges of machineries, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. KBS No. 5.4 with SOLID CONCRETE BLOCKS of Sizes 400 x 150 x 200mm: Third Floor:

710

1331

945521.2

... More
Man128 - Providing and Constructing Load Bearing Wall with SOLID CONCRETE BLOCKS having block density not less than 1800 Kg Cu.m having a minimum average compressive strength of 5.00 N Sq.mm confirming to IS 2185 (Part I):2005 and constructed with CM 1:4, as per IS 2572:2005 including cost of all materials labour charges, scaffolding, curing, hire charges of machineries, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. KBS No. 5.4 with SOLID CONCRETE BLOCKS of Sizes 400 x 150 x 200mm: Fourth Floor:

710

1345

954978.4

... More
Man129 - Providing and Constructing Load Bearing Wall with SOLID CONCRETE BLOCKS having block density not less than 1800 Kg Cu.m having a minimum average compressive strength of 5.00 N Sq.mm confirming to IS 2185 (Part I):2005 and constructed with CM 1:4, as per IS 2572:2005 including cost of all materials labour charges, scaffolding, curing, hire charges of machineries, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. KBS No. 5.4 with SOLID CONCRETE BLOCKS of Sizes 400 x 150 x 200mm: Fifth Floor:

710

1358

964527.9

... More
Man130 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer incharge of the works.: Ground Floor:

890

1159

1031688

... More
Man131 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer incharge of the works.: First Floor:

395

1170

462462.05

... More
Man132 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer incharge of the works.: Second Floor:

1515

1182

1791487.5

... More
Man133 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer incharge of the works.: Third Floor:

1515

1194

1809409.95

... More
Man134 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer incharge of the works.: Fourth Floor:

1515

1206

1827499.05

... More
Man135 - PLASTERING: Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Ceiling Plastering) : Lower Basement 01:

3694

309

1144216.5

... More
Man136 - PLASTERING: Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Ceiling Plastering) : Ground Floor:

3277

309

1015050.75

... More
Man137 - PLASTERING: Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Ceiling Plastering): First Floor:

4090

312

1279556.5

... More
Man138 - PLASTERING: Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Ceiling Plastering): Second Floor:

3395

315

1072752.1

... More
Man139 - PLASTERING: Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Ceiling Plastering): Third Floor:

4080

319

1302091.2

... More
Man140 - PLASTERING: Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Ceiling Plastering): Fourth Floor:

1970

322

634990.1

... More
Man141 - PLASTERING: Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Ceiling Plastering): Fifth Floor:

780

325

253929

... More
Man142 - 1. Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 Fine sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Water Proof Plastering Ceilings and Walls) 2. Extra for providing and mixing water proofing materials in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement]: LOWER BASEMENT 01

2029

396

805370.97

... More
Man143 - 1. Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 Fine sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Water Proof Plastering Ceilings and Walls) 2. Extra for providing and mixing water proofing materials in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement]: GROUND FLOOR

134

396

53188.62

... More
Man144 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Internal Plastering)

140

366

51303

... More
Man145 - 1. Providing 15mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. (Water Proof Plastering Walls + Floor of Lift and Toilets) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement].: LOWER BASEMENT 01

415

376

156206

... More
Man146 - 1. Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 Fine sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Ceiling Plastering): BASEMENT FLOOR:

20

384

7686

... More
Man147 - 1. Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 Fine sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Ceiling Plastering): GROUND FLOOR:

23

384

8838.9

... More
Man148 - 1. Providing 15mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. (Water Proof Plastering Walls + Floor of Lift and Toilets) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement].: Ground Floor:

170

376

63988

... More
Man149 - 1. Providing 15mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. (Water Proof Plastering Walls + Floor of Lift and Toilets) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement].: First Floor:

165

380

62726.4

... More
Man150 - 1. Providing 15mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. (Water Proof Plastering Walls + Floor of Lift and Toilets) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement].: Second Floor:

185

383

71032.6

... More
Man151 - 1. Providing 15mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. (Water Proof Plastering Walls + Floor of Lift and Toilets) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement].: Third Floor:

165

387

63987

... More
Man152 - 1. Providing 15mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. (Water Proof Plastering Walls + Floor of Lift and Toilets) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement].: Fourth Floor:

195

391

76377.6

... More
Man153 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Internal Plastering): LOWER BASEMENT 01

1475

366

540513.75

... More
Man154 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Internal Plastering): Ground Floor:

3438

366

1259855.1

... More
Man155 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Internal Plastering): FIRST FLOOR:

3075

370

1138088.25

... More
Man156 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Internal Plastering): SECOND FLOOR:

2815

373

1052275.15

... More
Man157 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Internal Plastering): THIRD FLOOR:

2740

377

1034487

... More
Man158 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Internal Plastering): Fourth FLOOR:

2000

381

762660

... More
Man159 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Internal Plastering): Fifth FLOOR:

1510

385

581561.4

... More
Man160 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Rough Cement Plastering.: Lower Basement 01

85

309

26328.75

... More
Man161 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Rough Cement Plastering.: Ground Floor:

455

309

140936.25

... More
Man162 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Rough Cement Plastering.: FIRST FLOOR:

405

312

126704.25

... More
Man163 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Rough Cement Plastering.: SECOND FLOOR:

575

315

181688.5

... More
Man164 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Rough Cement Plastering.: THIRD FLOOR:

405

319

129251.7

... More
Man165 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Rough Cement Plastering.: FOURTH FLOOR:

430

322

138601.9

... More
Man166 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Rough Cement Plastering.: FIFTH Floor:

75

325

24416.25

... More
Man167 - 1. Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. (External Plastering Water Proof Plastering) Walls Including CONCRETE Members and Stone Masonry) (External Plastering) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement] (External Plastering Water Proof Plastering) Walls (Including CONCRETE Members and Stone Masonry): 1. Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. (External Plastering Water Proof Plastering) Walls Including CONCRETE Members and Stone Masonry) (External Plastering) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement] (External Plastering Water Proof Plastering) Walls (Including CONCRETE Members and Stone Masonry): Sub Structure:

1330

415

552216

... More
Man168 - 1. Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. (External Plastering Water Proof Plastering) Walls Including CONCRETE Members and Stone Masonry) (External Plastering) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement] (External Plastering Water Proof Plastering) Walls (Including CONCRETE Members and Stone Masonry): LOWER BASEMENT 01:

1410

415

585432

... More
Man169 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. (External Surface, Lift Shaft and Duct Plastering): Lower Basement 01:

210

404

84892.5

... More
Man170 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. (External Surface, Lift Shaft and Duct Plastering): Ground Floor:

1215

404

491163.75

... More
Man171 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. (External Surface, Lift Shaft and Duct Plastering): First Floor:

1205

408

491989.45

... More
Man172 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. (External Surface, Lift Shaft and Duct Plastering): SECOND FLOOR:

975

412

402060.75

... More
Man173 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. (External Surface, Lift Shaft and Duct Plastering): THIRD FLOOR:

915

416

381088.35

... More
Man174 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. (External Surface, Lift Shaft and Duct Plastering): FOURTH FLOOR:

915

420

384894.75

... More
Man175 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. (External Surface, Lift Shaft and Duct Plastering): FIFTH FLOOR:

915

424

388746.9

... More
Man176 - Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof including cost of material, labour, scaffolding etc as per specifications and as per directions of the EngineerinCharge at all levels.

3280

64

209952.8

... More
Man177 - 1. Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Water Proof Plastering Floor and Ceiling) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement] : Sixth Floor:

330

421

139045.5

... More
Man178 - WATER PROOFING: Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500percent (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect selfadhesive polymer layer, etc, including surface preparation completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. Sub Structure:

1810

635

1149802.5

... More
Man179 - WATER PROOFING: Providing and laying water proofing treatment to the Retaining wall area with PU Elastomeric Single component liquid applied, cold applied, moisture cured high tensile elastomeric PU waterproofing membrane having elongation of more than 400percent and having solid content of above 90percent at 1.6kg per m2 in 2 coats to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g m2. The cost is inclusive of surface preparation, crack filling, repair of loose mortar etc. completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. Retaining wall: Sub Structure:

545

932

508158

... More
Man180 - WATER PROOFING: Providing and laying water proofing treatment to the Retaining wall area with PU Elastomeric Single component liquid applied, cold applied, moisture cured high tensile elastomeric PU waterproofing membrane having elongation of more than 400percent and having solid content of above 90percent at 1.6kg per m2 in 2 coats to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g m2. The cost is inclusive of surface preparation, crack filling, repair of loose mortar etc. completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. Retaining wall: Lower Basement 01: (Level 01):

1684

932

1570161.6

... More
Man181 - TERRACE WATER PROOFING: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely at all levels as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge.: Ground Floor:

506

857

434072.1

... More
Man182 - TERRACE WATER PROOFING: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely at all levels as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge.: Second Floor:

445

875

389415.05

... More
Man183 - TERRACE WATER PROOFING: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely at all levels as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge.: Terrace Floor:

1860

910

1693771.8

... More
Man184 - TERRACE WATER PROOFING: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely at all levels as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge.: Terrace Floor: Head Room

235

919

216138.9

... More
Man185 - Water retaining Structures: Retaining Structures: Providing and laying water proofing treatment to the Retaining wall area with PU Elastomeric Single component liquid applied, cold applied, moisture cured high tensile elastomeric PU waterproofing membrane having elongation of more than 400percent and having solid content of above 90percent at 1.6kg per m2 in 2 coats to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g m2. The cost is inclusive of surface preparation, crack filling, repair of loose mortar etc. completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. WALL : LOWER BASEMENT 01

50

932

46620

... More
Man186 - FOR TOILETS SUNK PORTIONS: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. Sunken portion of WC:Bathroom: Ground Floor:

170

857

145834.5

... More
Man187 - FOR TOILETS SUNK PORTIONS: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. Sunken portion of WC:Bathroom: First Floor:

105

866

90975.15

... More
Man188 - FOR TOILETS SUNK PORTIONS: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. Sunken portion of WC:Bathroom: Second Floor:

180

875

157516.2

... More
Man189 - FOR TOILETS SUNK PORTIONS: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. Sunken portion of WC:Bathroom: Third Floor:

180

883

159091.2

... More
Man190 - FOR TOILETS SUNK PORTIONS: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. Sunken portion of WC:Bathroom: Fourth Floor:

180

892

160682.4

... More
Man191 - Swellable rapid expansion water proofing for construction joints in all types of concrete works composite works: Providing and fixing PVC water stopper of suitable type of 230 mm width and 5 mm thickness for construction joints as per detailed technical specifications and as directed by Engineerin charge: Sub Structure Floor:: UP TO Foundation LVL

1245

325

405247.5

... More
Man192 - Swellable rapid expansion water proofing for construction joints in all types of concrete works composite works: Providing and fixing PVC water stopper of suitable type of 230 mm width and 5 mm thickness for construction joints as per detailed technical specifications and as directed by Engineerin charge: Lower Basement FLOOR: Level 01:

1800

325

585900

... More
Man193 - Swellable rapid expansion water proofing for construction joints in all types of concrete works composite works: Providing and fixing PVC water stopper of suitable type of 230 mm width and 5 mm thickness for construction joints as per detailed technical specifications and as directed by Engineerin charge: GROUND FLOOR: Level 02:

50

325

16275

... More
Man194 - Swellable rapid expansion water proofing for construction joints in all types of concrete works composite works: Providing and fixing PVC water stopper of suitable type of 230 mm width and 5 mm thickness for construction joints as per detailed technical specifications and as directed by Engineerin charge: First FLOOR: Level 03:

50

328

16438

... More
Man195 - Swellable rapid expansion water proofing for construction joints in all types of concrete works composite works: Providing and fixing PVC water stopper of suitable type of 230 mm width and 5 mm thickness for construction joints as per detailed technical specifications and as directed by Engineerin charge: Second FLOOR: Level 04:

50

332

16602.5

... More
Man196 - Swellable rapid expansion water proofing for construction joints in all types of concrete works composite works: Providing and fixing PVC water stopper of suitable type of 230 mm width and 5 mm thickness for construction joints as per detailed technical specifications and as directed by Engineerin charge: Third FLOOR: Level 05:

50

335

16768.5

... More
Man197 - Swellable rapid expansion water proofing for construction joints in all types of concrete works composite works: Providing and fixing PVC water stopper of suitable type of 230 mm width and 5 mm thickness for construction joints as per detailed technical specifications and as directed by Engineerin charge: Fourth FLOOR: Level 05:

65

338

22016.8

... More
Man198 - Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. suitable plaster mesh 150mm wide.: Lower Basement 01

458

39

18274.2

... More
Man199 - Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. suitable plaster mesh 150mm wide.: Ground Floor

680

39

27132

... More
Man200 - Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. suitable plaster mesh 150mm wide.: First Floor

630

40

25389

... More
Man201 - Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. suitable plaster mesh 150mm wide.: Second Floor

755

40

30728.5

... More
Man202 - Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. suitable plaster mesh 150mm wide.: Third Floor

755

41

31038.05

... More
Man203 - Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. suitable plaster mesh 150mm wide.: Fourth Floor

715

41

29686.8

... More
Man204 - Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. suitable plaster mesh 150mm wide.: Fifth Floor

555

41

23276.7

... More
Man205 - FLOORING WORKS: Providing and laying Cement concrete flooring 100 mm thick with 20mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. 100mm Thick Ground Floor: (Level 02):

540

1183

639295.2

... More
Man206 - FLOORING WORKS: Providing and laying Cement concrete flooring 75 mm thick with 20mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. 75mm Thick

219

473

103718.4

... More
Man207 - Vaccum dewatering with vaccum pump and suction mat and compaction with skin floater clubbed with floating disc including cost of generator, HOM of machinery, Screed Vibratory, Power Floater, blade and disc etc., with all lead and lift. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : (i). Lower Basement 01: (Level 01):

2010

71

143514

... More
Man208 - Vaccum dewatering with vaccum pump and suction mat and compaction with skin floater clubbed with floating disc including cost of generator, HOM of machinery, Screed Vibratory, Power Floater, blade and disc etc., with all lead and lift. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : (ii). Ground Floor: (Level 02):

400

71

28560

... More
Man209 - Providing groove cutting for width of 5mm to 10mm and depth 80mm 100mm including cost of cutting machine, generator and HOM, including cost of blade,coolant etc., including cleaning of groove and providing sand and hot bitumen fillars, and filler metal etc., including cost of conveyance of all materials, labour, lead and lift charges and all other incidental charges as per drawing and as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. for concrete pavement : (i). Lower Basement 01: (Level 01):

750

141

106312.5

... More
Man210 - Providing groove cutting for width of 5mm to 10mm and depth 80mm 100mm including cost of cutting machine, generator and HOM, including cost of blade,coolant etc., including cleaning of groove and providing sand and hot bitumen fillars, and filler metal etc., including cost of conveyance of all materials, labour, lead and lift charges and all other incidental charges as per drawing and as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. for concrete pavement : (ii). Ground Floor: (Level 02):

175

141

24806.25

... More
Man211 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Average 100mm Thick. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin Charge.: Lower Basement 01: (Level 01):

2010

1126

2263722.3

... More
Man212 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates TERRACE SCREED and LOWER BASEMENT FLOOR. Average 100mm Thick. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin Charge.: Ground Floor:

140

1126

157672.2

... More
Man213 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Average 100mm Thick. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin Charge.: SECOND Floor:

445

1148

511242.7

... More
Man214 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Average 100mm Thick. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin Charge.: THIRD Floor:

445

1160

516355.75

... More
Man215 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Average 100mm Thick. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin Charge.: Terrace Floor:

1860

1183

2201626.2

... More
Man216 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Average 100mm Thick. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin Charge.: Terrace Floor: Head Room

235

1195

280944.85

... More
Man217 - Providing and fixing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement: 4 coarse sand) mixed with 2percent integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. (Basic Cost of Pressed Clay Tiles 20mm thick 250 x 250mm Size Rs. 9030 for 1000 Nos.): Ground Floor:

140

593

83055

... More
Man218 - Providing and fixing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement: 4 coarse sand) mixed with 2percent integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. (Basic Cost of Pressed Clay Tiles 20mm thick 250 x 250mm Size Rs. 9030 for 1000 Nos.): SECOND Floor:

445

605

269300.65

... More
Man219 - Providing and fixing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement: 4 coarse sand) mixed with 2percent integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. (Basic Cost of Pressed Clay Tiles 20mm thick 250 x 250mm Size Rs. 9030 for 1000 Nos.): THIRD Floor:

445

611

271992.9

... More
Man220 - Providing and fixing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement: 4 coarse sand) mixed with 2percent integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. (Basic Cost of Pressed Clay Tiles 20mm thick 250 x 250mm Size Rs. 9030 for 1000 Nos.): Terrace Floor:

1860

623

1159710

... More
Man221 - Providing and fixing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement: 4 coarse sand) mixed with 2percent integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. (Basic Cost of Pressed Clay Tiles 20mm thick 250 x 250mm Size Rs. 9030 for 1000 Nos.): Terrace Floor: Head Room

235

629

147988.9

... More
Man222 - ANTI SKID VITRIFIED TILES: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. ANTI SKID VITRIFIED TILES 600mm x 600mm: Ground Floor:

110

1202

132247.5

... More
Man223 - ANTI SKID VITRIFIED TILES: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. ANTI SKID VITRIFIED TILES 600mm x 600mm: First Floor:

110

1214

133569.7

... More
Man224 - ANTI SKID VITRIFIED TILES: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. ANTI SKID VITRIFIED TILES 600mm x 600mm: Second Floor:

125

1226

153301.25

... More
Man225 - ANTI SKID VITRIFIED TILES: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. ANTI SKID VITRIFIED TILES 600mm x 600mm: Third Floor:

110

1238

136253.7

... More
Man226 - ANTI SKID VITRIFIED TILES: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. ANTI SKID VITRIFIED TILES 600mm x 600mm: Fourth Floor:

190

1251

237701.4

... More
Man227 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Tiles 300 x 600. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Ground Floor:

320

1161

371616

... More
Man228 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Tiles 300 x 600. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : FIRST FLOOR:

320

1172

375331.2

... More
Man229 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Tiles 300 x 600. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : SECOND FLOOR:

490

1184

580473.6

... More
Man230 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Tiles 300 x 600. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : THIRD FLOOR:

320

1196

382876.8

... More
Man231 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Tiles 300 x 600. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : FOURTH FLOOR:

355

1208

428999.75

... More
Man232 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. VITRIFIED Tiles 300 x 450. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Lower Basement 01

80

1161

92904

... More
Man233 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. VITRIFIED Tiles 300 x 450. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Ground Floor:

75

1161

87097.5

... More
Man234 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. VITRIFIED Tiles 300 x 450. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: FIRST FLOOR:

80

1172

93832.8

... More
Man235 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. VITRIFIED Tiles 300 x 450. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: SECOND FLOOR:

80

1184

94771.2

... More
Man236 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. VITRIFIED Tiles 300 x 450. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: THIRD FLOOR:

80

1196

95719.2

... More
Man237 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. VITRIFIED Tiles 300 x 450. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: FOURTH FLOOR:

80

1208

96676

... More
Man238 - Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.: Lower Basement 01:

120

5594

671328

... More
Man239 - Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.: Ground Floor:

160

5594

895104

... More
Man240 - Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.: FIRST FLOOR

85

5650

480278.9

... More
Man241 - Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.: SECOND FLOOR

80

5706

456547.2

... More
Man242 - Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.: THIRD FLOOR

80

5763

461112.8

... More
Man243 - Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.: FOURTH FLOOR

90

5821

523939.5

... More
Man244 - Providing and laying Flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.: GROUND FLOOR:

190

2589

491967

... More
Man245 - Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Size of the Tiles : 600 x 600: GROUND FLOOR:

1518

1202

1825015.5

... More
Man246 - Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Size of the Tiles : 600 x 600: FIRST FLOOR

1450

1214

1760691.5

... More
Man247 - Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Size of the Tiles : 600 x 600: SECOND FLOOR:

1690

1226

2072632.9

... More
Man248 - Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Size of the Tiles : 600 x 600: THIRD FLOOR

935

1238

1158156.45

... More
Man249 - Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Size of the Tiles : 600 x 600: FOURTH FLOOR

385

1251

481658.1

... More
Man250 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.: Lower Basement 01:

50

2994

149730

... More
Man251 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.: Ground Floor:

375

2994

1122975

... More
Man252 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.: First Floor:

280

3024

846874

... More
Man253 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge. Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.: Second Floor:

660

3054

2016168

... More
Man254 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge. Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.: THIRD Floor:

680

3085

2098038

... More
Man255 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge. Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.: Fourth Floor:

55

3116

171391

... More
Man256 - Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. LIFT PORTION: Lower Basement 01

25

3787

94683.75

... More
Man257 - Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. LIFT PORTION: Ground Floor:

25

3787

94683.75

... More
Man258 - Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. LIFT PORTION: FIRST FLOOR:

25

3825

95630.5

... More
Man259 - Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. LIFT PORTION: SECOND FLOOR:

25

3863

96586.75

... More
Man260 - Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. LIFT PORTION: THIRD FLOOR:

25

3902

97552.5

... More
Man261 - Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. LIFT PORTION: Fourth Floor:

25

3941

98528

... More
Man262 - Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. FRONT ENTRY PORTION : Ground Floor:

120

3526

423234

... More
Man263 - Supplying, fabricating and fixing of Stainless steel cladding for walls using 304 grade Stainless steel 16 guage sheet wall cladding of thickness over the frame made out of 50x50mmx3mm thickness anodized aluminium frame work at an equal distance of 2 ft vertifically fixed to the wall using 100mm screws, guttas, anchor bolts and fastners with all necessary bending and cutting as per the desing and site condition. The frame work finally to be finished with 12mm BWP plywood to receive the SS sheet on it uniformly. Including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Lower Basement 01

5

13097

65486

... More
Man264 - Supplying, fabricating and fixing of Stainless steel cladding for walls using 304 grade Stainless steel 16 guage sheet wall cladding of thickness over the frame made out of 50x50mmx3mm thickness anodized aluminium frame work at an equal distance of 2 ft vertifically fixed to the wall using 100mm screws, guttas, anchor bolts and fastners with all necessary bending and cutting as per the desing and site condition. The frame work finally to be finished with 12mm BWP plywood to receive the SS sheet on it uniformly. Including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Ground Floor:

5

12967

64837.5

... More
Man265 - Supplying, fabricating and fixing of Stainless steel cladding for walls using 304 grade Stainless steel 16 guage sheet wall cladding of thickness over the frame made out of 50x50mmx3mm thickness anodized aluminium frame work at an equal distance of 2 ft vertifically fixed to the wall using 100mm screws, guttas, anchor bolts and fastners with all necessary bending and cutting as per the desing and site condition. The frame work finally to be finished with 12mm BWP plywood to receive the SS sheet on it uniformly. Including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : FIRST FLOOR:

5

13097

65486

... More
Man266 - Supplying, fabricating and fixing of Stainless steel cladding for walls using 304 grade Stainless steel 16 guage sheet wall cladding of thickness over the frame made out of 50x50mmx3mm thickness anodized aluminium frame work at an equal distance of 2 ft vertifically fixed to the wall using 100mm screws, guttas, anchor bolts and fastners with all necessary bending and cutting as per the desing and site condition. The frame work finally to be finished with 12mm BWP plywood to receive the SS sheet on it uniformly. Including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : SECOND FLOOR:

5

13226

66134.5

... More
Man267 - Supplying, fabricating and fixing of Stainless steel cladding for walls using 304 grade Stainless steel 16 guage sheet wall cladding of thickness over the frame made out of 50x50mmx3mm thickness anodized aluminium frame work at an equal distance of 2 ft vertifically fixed to the wall using 100mm screws, guttas, anchor bolts and fastners with all necessary bending and cutting as per the desing and site condition. The frame work finally to be finished with 12mm BWP plywood to receive the SS sheet on it uniformly. Including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : THIRD FLOOR:

5

13356

66783

... More
Man268 - Supplying, fabricating and fixing of Stainless steel cladding for walls using 304 grade Stainless steel 16 guage sheet wall cladding of thickness over the frame made out of 50x50mmx3mm thickness anodized aluminium frame work at an equal distance of 2 ft vertifically fixed to the wall using 100mm screws, guttas, anchor bolts and fastners with all necessary bending and cutting as per the desing and site condition. The frame work finally to be finished with 12mm BWP plywood to receive the SS sheet on it uniformly. Including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Fourth FLOOR:

5

13486

67431

... More
Man269 - Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineerin charge and finished smooth.: Ground Floor:

5

2928

14642.25

... More
Man270 - Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineerin charge and finished smooth.: First Floor:

5

2957

14788.65

... More
Man271 - Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineerin charge and finished smooth.: Second Floor:

10

2987

29873.1

... More
Man272 - Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineerin charge and finished smooth.: Third Floor:

10

3017

30171.8

... More
Man273 - Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineerin charge and finished smooth.: Fourth Floor:

10

3047

30473.5

... More
Man274 - Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Ground Floor:

15

4133

62007.75

... More
Man275 - Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : First Floor:

10

4175

41751.9

... More
Man276 - Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Second Floor:

15

4216

63254.1

... More
Man277 - Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Third Floor:

15

4259

63886.65

... More
Man278 - Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Fourth Floor:

15

4301

64525.5

... More
Man279 - Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Ground Floor:

110

2117

232963.5

... More
Man280 - Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : First Floor:

110

2139

235293.3

... More
Man281 - Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Second Floor:

125

2160

270052.5

... More
Man282 - Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Third Floor:

110

2182

240022.2

... More
Man283 - Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Fourth Floor:

190

2203

418729.6

... More
Man284 - Providing and laying Cement concrete flooring 75 mm thick with 20mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. 75mm Thick: Lower Basement 01:

35

887

31076.85

... More
Man285 - Providing and laying Cement concrete flooring 75 mm thick with 20mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. 75mm Thick: Ground Floor:

95

887

84351.45

... More
Man286 - Providing and laying Cement concrete flooring 75 mm thick with 20mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. 75mm Thick: First Floor:

35

896

31387.65

... More
Man287 - Providing and laying Cement concrete flooring 75 mm thick with 20mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. 75mm Thick: Second Floor:

35

905

31701.6

... More
Man288 - Providing and laying Cement concrete flooring 75 mm thick with 20mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. 75mm Thick: Third Floor:

35

914

32018.7

... More
Man289 - Providing and laying Cement concrete flooring 75 mm thick with 20mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. 75mm Thick: Fourth Floor:

1485

923

1372095.45

... More
Man290 - Providing and laying cement concrete using 20mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete for RCC works laid in 15 cm thick layers and well compacted including vibrating curing etc., for all super structure works with all lead and lift etc., complete. (exculsive of cost of steel and fabrication charges) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Ready mixed Cement concrete M20. [Screed for Rays ways]. [Screed for Rays ways, Above Cinder and Concrete Band for 100mm Wall] : (i). Ground Floor:

148

6961

1030302

... More
Man291 - Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates TERRACE FLOOR. Average 100mm Thick.

24

6961

167076

... More
Man292 - Providing and laying cement concrete using 20mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete for RCC works laid in 15 cm thick layers and well compacted including vibrating curing etc., for all super structure works with all lead and lift etc., complete. (exculsive of cost of steel and fabrication charges) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Ready mixed Cement concrete M20. [Screed for Rays ways]. [Screed for Rays ways, Above Cinder and Concrete Band for 100mm Wall] : (ii). First Floor:

140

7031

984356.8

... More
Man293 - Providing and laying cement concrete using 20mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete for RCC works laid in 15 cm thick layers and well compacted including vibrating curing etc., for all super structure works with all lead and lift etc., complete. (exculsive of cost of steel and fabrication charges) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Ready mixed Cement concrete M20. [Screed for Rays ways]. [Screed for Rays ways, Above Cinder and Concrete Band for 100mm Wall] : (iii). Second Floor:

15

7101

106521.45

... More
Man294 - Providing and laying cement concrete using 20mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete for RCC works laid in 15 cm thick layers and well compacted including vibrating curing etc., for all super structure works with all lead and lift etc., complete. (exculsive of cost of steel and fabrication charges) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Ready mixed Cement concrete M20. [Screed for Rays ways]. [Screed for Rays ways, Above Cinder and Concrete Band for 100mm Wall] : (iii). Third Floor:

15

7172

107586.6

... More
Man295 - Providing and laying cement concrete using 20mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete for RCC works laid in 15 cm thick layers and well compacted including vibrating curing etc., for all super structure works with all lead and lift etc., complete. (exculsive of cost of steel and fabrication charges) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Ready mixed Cement concrete M20. [Screed for Rays ways]. [Screed for Rays ways, Above Cinder and Concrete Band for 100mm Wall] : (iii). Fourth Floor:

25

7244

181104

... More
Man296 - Providing and fixing corrugated G.S. sheet roofing including vertical curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g m²

2031

950

1931318.52

... More
Man297 - Providing and fixing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete as per design drawings. 0.63 mm thick with zinc coating not less than 275 g m²

750

691

518460

... More
Man298 - Providing and fixing 15 cm wide, 45 cm overall semicircular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. (0.63 mm thick with zinc coating not less than 275 g m²)

213

697

148625.01

... More
Man299 - DOORS, WINDOWS: and VENTILATORS: Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. red sal

8

105851

846813.76

... More
Man300 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Fixing of Door Frame

140

1088

152369

... More
Man301 - Providing and fixing factory made single extruded Wood Polymer Composite (WPC) solid door window Ceosetory windows and Frames Chowkhat of Frame size 65 x 125 mm including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.

305

818

249612

... More
Man302 - Providing and fixing to existing door frames. Providing and fixing factory made 100percent Carpenter friendly ready to use Single Solid Plain Wood Polymer composite (WPC) flush shutter of 35mm thickness which is anti termite and having high water absorption property. The cost includes cost of materials, transportation, Labour and fixing charges. 35 mm thick including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.

145

4328

627670.2

... More
Man303 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (partI) 1991. from manufacturer complete as per spcification. 40 mm thick both side Teak Single Double Leaf Door

190

4331

823076.2

... More
Man304 - Providing and fixing Double Shutter Glass Door of 12mm Thick Plain Toughened Glass of approved makke. The door is fixed by using any approved make hardware fitting like patch fitting, pivot, floor machine, locking arrangements and suitable SS Door rails with floral Glass etching for 1 3 Portion of door area etc.,,, complete. The rate includes cost of all materials, labour, hire of tools and machineries, as per the specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.

125

5058

632282.5

... More
Man305 - SPECIFICATION for UPVC VENTILATOR with FIXED LOUVERS: Providing and fixing of Louvered Ventilator made out of multi chambered UPVC (Matching to RAL9016) sections and with minimum TiO2 (Titanium Dioxide) at 6PHR with TPV (Thermo Plastic Vulcanized) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile thoroughout the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (Powder Coated in White) will be used on the frame along with plastic parts for fixing the 4mm pin head glass. Wall thickness of frame shall be 2mm. Maximum Possible size 1500mm x 1000mm. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.

32

6126

196040.32

... More
Man306 - FIRE RATED DOOR: WOODEN FIRE RATED FLUSH DOOR:Providing , supply and fixing of Two Hours Fire rated timber door of specified size as per drawing with timber frame made out of Teak Wood Hard Wood (as per the Architect Suggestion and approval) with frame profile of 140 x 70mm with SINGLE REBATE FRAME with heat activated intumescent fire seal strip of 10mm x 4mm and two coat of anti termite with synthetic enamel paint of approved shade and shutters of 55mm thick asbestos freecomposite Fire Smoke check wooden shuttersof 120minutes fire resistance rating confirming to BS:476 Part 22 and IS: 2614 Part II. comprising of 12mm thick Calicium sillicate board sandwiching 25mm thickn proprietary fire resistane insulation material faced with 3mm commercial Ply on both side with heat activated inducement fire seal strip of size 10mm x 4mm mounted on grooves on three sides except bottom and two coats of anti termite fire retardant primer and anti termite primer, 1mm thick approved shade and pattern Laminate standard grade of approved colour (highland pine shade) and 4mm approved shade and pattern Veneer and Marquetry pattern. shall be faced with 1mm thick laminate standard grade of approved colour (highland pine shade) finish on both faces including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. The Hardware set for the Door are mentioned below: FD1 1500mm x 2400mm Wall openings size with VISION PANEL of Size 200 x 450mm as per Dwg. for Auditorium 1 Ball bearing butt hinge,SS304, of size 100 X 75 X 3mm with screws in SSS Homann 8 Nos 2. Mortice Sash Lock, H9GUBKS 2160, 65 BS 72 9mm, Rd.forend, strile, CE, CE, Silver finish,(LH) Hormann 1 No 3. Euro profile 5 pin cylinder 5702, 70mm key x key, NP finish Homann 1 No 4. Lever Handle LT 001, 19 Dia with roses and escutcheion, SS 304 , SSS finsih Homann 1 No 5. Surface door closer TS68, size EN2 3 4, with standard arm, Silver finish Dorma 2 Nos 6. Gravity door coordinator 390G , Dorma 1 No 7. Concealed flush bolt RB10 body Guardian 2 Nos 8. Rod for flush bolt 570mm Guardian 1 No 9. Surface auto door bottom 914mm, Aluminium finsih Hormann 2 No 10. Rod for flush bolt 265mm Guardian 1 No 11. Gasket, Fire rated 4mm Thick x 12mm, Black 7 Nos 12. Fire clear glass6mm 200x450mm 2 No 13. Fire and smoke seal C421 (Art. no. 315092), black Hormann sales 7 Nos 14. Installation Kit: Nylon Achor and other Misc items 1 No

18

9660

173880

... More
Man307 - 120Mins with 30Mins. Insulated fire door as per IS 3614 Powder coated Providing and fixing of Heavy Duty hollow metal fire rated doors as per IS 3614, for stability,integrity and insulation. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2, IS ISO 8341, BS 476 Part 20 and 22, CBRI Cerifire, for maximum rating of 120mins with 30minutes of insulation. Labled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Manufacturer test certificate shall cover sizes of all doors supplied, deviation in sheet thickness other than what is mentioned in the BOQ are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Door frame must be single rebate grooved profile of size 125 x 55mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered only. Frames shall be field assembled with self tabs. Bolted and butted joints are not acceptable. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM C421 gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening.Once frame installed should be filled with PUF as recomended by the manufacturer or engineer incharge. Door leaf shall be minimum 46mm thick fully flush double skin door, Insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware of make Dorma Hormann Hafele. The infill material shall be high density insulation material. Intumescent seals 15x1.5mm to be provided all around the door in addition to the grooved smoke seal. The edges should be interlocked with a bending radius of 1.4mm, without any tak welding on edges. For pair of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. No surface mounted or weld joint astragals are acceptable. Vision lite wherever applicable should be 6mm clear borosilicate fire rated glass as per manufacturers recommendation with a clipon arrangement. Door and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of frame and shutter as a complete assembly including hardware. FD1 1500mm x 2400mm Wall openings size with VISION PANEL of Size 200 x 450mm as per Dwg. for Services Room The Hardware set for the Door are mentioned below: 1 Ball bearing butt hinge,SS304, of size 100 X 75 X 3mm with screws in SSS Homann 8 Nos 2. Mortice Sash Lock, H9GUBKS 2160, 65 BS 72 9mm, Rd.forend, strile, CE, CE, Silver finish,(LH) Hormann 1 No 3. Euro profile 5 pin cylinder 5702, 70mm key x key, NP finish Homann 1 No 4. Lever Handle LT 001, 19 Dia with roses and escutcheion, SS 304 , SSS finsih Homann 1 No 5. Surface door closer TS68, size EN2 3 4, with standard arm, Silver finish Dorma 2 Nos 6. Gravity door coordinator 390G , Dorma 1 No 7. Concealed flush bolt RB10 body Guardian 2 Nos 8. Rod for flush bolt 570mm Guardian 1 No 9. Surface auto door bottom 914mm, Aluminium finsih Hormann 2 No 10. Rod for flush bolt 265mm Guardian 1 No 11. Gasket, Fire rated 4mm Thick x 13mm, Black 7 Nos 12. Fire clear glass6mm 200x450mm 2 No 13. Fire and smoke seal C421 (Art. no. 315092), black Hormann sales 7 Nos 14. Installation Kit: Nylon Achor and other Misc items 1 No

22

11839

260458

... More
Man308 - 120Mins with 30Mins. Insulated fire door as per IS 3614 Powder coated Providing and fixing of Heavy Duty hollow metal fire rated doors as per IS 3614, for stability,integrity and insulation. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2, IS ISO 8341, BS 476 Part 20 and 22, CBRI Cerifire, for maximum rating of 120mins with 30minutes of insulation. Labled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Manufacturer test certificate shall cover sizes of all doors supplied, deviation in sheet thickness other than what is mentioned in the BOQ are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Door frame must be single rebate grooved profile of size 125 x 55mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered only. Frames shall be field assembled with self tabs. Bolted and butted joints are not acceptable. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM C421 gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening.Once frame installed should be filled with PUF as recomended by the manufacturer or engineer incharge. Door leaf shall be minimum 46mm thick fully flush double skin door, Insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware of make Dorma Hormann Hafele. The infill material shall be high density insulation material. Intumescent seals 15x1.5mm to be provided all around the door in addition to the grooved smoke seal. The edges should be interlocked with a bending radius of 1.4mm, without any tak welding on edges. For pair of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. No surface mounted or weld joint astragals are acceptable. Vision lite wherever applicable should be 6mm clear borosilicate fire rated glass as per manufacturers recommendation with a clipon arrangement. Door and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of frame and shutter as a complete assembly including hardware. FD2 1800x2400mm Wall opening size with VISION PANEL of size 200 x 450mm as per Dwg. for Staircases. The Hardware set for the Door are mentioned below: 1 Ball bearing butt hinge,SS304, of size 100 X 75 X 3mm with screws in SSS Homann 8 Nos 2. Mortice Sash Lock, H9GUBKS 2160, 65 BS 72 9mm, Rd.forend, strile, CE, CE, Silver finish,(LH) Hormann 1 No 3. Euro profile 5 pin cylinder 5702, 70mm key x key, NP finish Homann 1 No 4. Lever Handle LT 001, 19 Dia with roses and escutcheion, SS 304 , SSS finsih Homann 1 No 5. Surface door closer TS68, size EN2 3 4, with standard arm, Silver finish Dorma 2 Nos 6. Gravity door coordinator 390G , Dorma 1 No 7. Concealed flush bolt RB10 body Guardian 2 Nos 8. Rod for flush bolt 570mm Guardian 1 No 9. Surface auto door bottom 914mm, Aluminium finsih Hormann 2 No 10. Rod for flush bolt 265mm Guardian 1 No 11. Gasket, Fire rated 4mm Thick x 13mm, Black 7 Nos 12. Fire clear glass6mm 200x450mm 2 No 13. Fire and smoke seal C421 (Art. no. 315092), black Hormann sales 7 Nos 14. Installation Kit: Nylon Achor and other Misc items 1 No

52

10333

537316

... More
Man309 - 120Mins with 30Mins. Insulated fire door as per IS 3614 Powder coated Providing and fixing of Heavy Duty hollow metal fire rated doors as per IS 3614, for stability,integrity and insulation. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2, IS ISO 8341, BS 476 Part 20 and 22, CBRI Cerifire, for maximum rating of 120mins with 30minutes of insulation. Labled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Manufacturer test certificate shall cover sizes of all doors supplied, deviation in sheet thickness other than what is mentioned in the BOQ are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Door frame must be single rebate grooved profile of size 125 x 55mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered only. Frames shall be field assembled with self tabs. Bolted and butted joints are not acceptable. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM C421 gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening.Once frame installed should be filled with PUF as recomended by the manufacturer or engineer incharge. Door leaf shall be minimum 46mm thick fully flush double skin door, Insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware of make Dorma Hormann Hafele. The infill material shall be high density insulation material. Intumescent seals 15x1.5mm to be provided all around the door in addition to the grooved smoke seal. The edges should be interlocked with a bending radius of 1.4mm, without any tak welding on edges. For pair of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. No surface mounted or weld joint astragals are acceptable. Vision lite wherever applicable should be 6mm clear borosilicate fire rated glass as per manufacturers recommendation with a clipon arrangement. Door and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of frame and shutter as a complete assembly including hardware. FD2 1800x2400mm Wall opening size with VISION PANEL of size 200 x 450mm as per Dwg. for Staircases. The Hardware set for the Door are mentioned below: 1.Ball bearing butt hinge, SS304, of size 100 X 75 X 3mm with screws in SSS Homann 8Nos 2. Surface door closer TS68, size EN2 3 4, with standard arm, Silver finish Dorma 2 No 3. Surface auto door bottom 914 mm, Aluminium finish Hormann 2 No 4. Single point surface panic push bar 1211, Silver finish Hormann 4 No 5. External lever handle , 1185, with locking arrangement, Silver finish Hormann 2 No 6. Gasket, Fire rated 4mm Thick x 13mm , Black 4 Nos 7. Fire clear glass 6mm 200 X 450mm 2 No 8. Fire and Smoke seal C421 (Art. No. 315092), black Hormann Sales 8 Nos 9. Installation kit: Nylon Achor and other Misc items 1 no

52

11839

615628

... More
Man310 - 120Mins with 30Mins. Insulated fire door as per IS 3614 Powder coated Providing and fixing of Heavy Duty hollow metal fire rated doors as per IS 3614, for stability,integrity and insulation. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2, IS ISO 8341, BS 476 Part 20 and 22, CBRI Cerifire, for maximum rating of 120mins with 30minutes of insulation. Labled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Manufacturer test certificate shall cover sizes of all doors supplied, deviation in sheet thickness other than what is mentioned in the BOQ are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Door frame must be single rebate grooved profile of size 125 x 55mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered only. Frames shall be field assembled with self tabs. Bolted and butted joints are not acceptable. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM C421 gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening.Once frame installed should be filled with PUF as recomended by the manufacturer or engineer incharge. Door leaf shall be minimum 46mm thick fully flush double skin door, Insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware of make Dorma Hormann Hafele. The infill material shall be high density insulation material. Intumescent seals 15x1.5mm to be provided all around the door in addition to the grooved smoke seal. The edges should be interlocked with a bending radius of 1.4mm, without any tak welding on edges. For pair of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. No surface mounted or weld joint astragals are acceptable. Vision lite wherever applicable should be 6mm clear borosilicate fire rated glass as per manufacturers recommendation with a clipon arrangement. Door and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of frame and shutter as a complete assembly including hardware. FD2 1200x2400mm Wall opening size with VISION PANEL of 200mm x 450mm as per dwg. for ELECTRICAL Room The Hardware set for the Door are mentioned below: 1. Ball bearing Butt Hinges, SS304, 100 x 75 x 3mm with Screws in SSS: Hormann 4 Nos. 2. Single Point Surface Panic Push bar 1211, Silver finish Hormann 1 Nos. 3.External Lever Handle, 1185, wtih locking arrangement, Silver finish Hormann 1 Nos.. 4. Surface Door Closure TS68, Size EN2 3 4, with Standard arm, Silver finish: Dorma 1 Nos. 5. Fire Clear Glass 6mm: 120 min. of size 200 x 450mm 1 Nos. 6. Fire and smoke seal C421 (Art No. 315092), Black Hormann Sales 6 Nos. 7. Surface Auto Door Bottom 914mm, Aluminium Finish Hormann 1 Nos. 8. Gasket, Fire rated 4mm Thick X 13mm, Black 4 Nos. 9. Installation Kit: Nylon Achor and other Miscellaneous Items 1 Nos.

70

9550

668500

... More
Man311 - 120Mins with 30Mins. Insulated fire door as per IS 3614 Powder coated Providing and fixing of Heavy Duty hollow metal fire rated doors as per IS 3614, for stability,integrity and insulation. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2, IS ISO 8341, BS 476 Part 20 and 22, CBRI Cerifire, for maximum rating of 120mins with 30minutes of insulation. Labled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Manufacturer test certificate shall cover sizes of all doors supplied, deviation in sheet thickness other than what is mentioned in the BOQ are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Door frame must be single rebate grooved profile of size 125 x 55mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered only. Frames shall be field assembled with self tabs. Bolted and butted joints are not acceptable. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM C421 gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening.Once frame installed should be filled with PUF as recomended by the manufacturer or engineer incharge. Door leaf shall be minimum 46mm thick fully flush double skin door, Insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware of make Dorma Hormann Hafele. The infill material shall be high density insulation material. Intumescent seals 15x1.5mm to be provided all around the door in addition to the grooved smoke seal. The edges should be interlocked with a bending radius of 1.4mm, without any tak welding on edges. For pair of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. No surface mounted or weld joint astragals are acceptable. Vision lite wherever applicable should be 6mm clear borosilicate fire rated glass as per manufacturers recommendation with a clipon arrangement. Door and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of frame and shutter as a complete assembly including hardware. SD 01: 900x1800mm Wall opening size with VISION PANEL of Size 200 x 450mm as per Dwg. for FHC. The Hardware set for the Door are mentioned below: 1. Ball bearing butt hinge, SS304, of size 100 X 75 X 3mm with screws in SSS Homann 3 Nos 2. Mortise shaft lolck H7, 57mm BS, with Allen Key and escutcheons, sss Hormann 1 No 3. Flush handle, CH 120S, 120X40mm, SSS finish Hormann 4. Fire and Smoke seal C421 (Art. No. 315092), black Hormann Sales 5 Nos 5. Gasket, Fire rated 4mm Thick x 13mm , Black 4 Nos 6. Fire clear glass 6mm 200 X 300mm 1 No 7. Installation kit: Nylon Achor and other Misc items 1 no

34

9850

334900

... More
Man312 - 120Mins with 30Mins. Insulated fire door as per IS 3614 Powder coated Providing and fixing of Heavy Duty hollow metal fire rated doors as per IS 3614, for stability,integrity and insulation. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2, IS ISO 8341, BS 476 Part 20 and 22, CBRI Cerifire, for maximum rating of 120mins with 30minutes of insulation. Labled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Manufacturer test certificate shall cover sizes of all doors supplied, deviation in sheet thickness other than what is mentioned in the BOQ are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Door frame must be single rebate grooved profile of size 125 x 55mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered only. Frames shall be field assembled with self tabs. Bolted and butted joints are not acceptable. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM C421 gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening.Once frame installed should be filled with PUF as recomended by the manufacturer or engineer incharge. Door leaf shall be minimum 46mm thick fully flush double skin door, Insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware of make Dorma Hormann Hafele. The infill material shall be high density insulation material. Intumescent seals 15x1.5mm to be provided all around the door in addition to the grooved smoke seal. The edges should be interlocked with a bending radius of 1.4mm, without any tak welding on edges. For pair of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. No surface mounted or weld joint astragals are acceptable. Vision lite wherever applicable should be 6mm clear borosilicate fire rated glass as per manufacturers recommendation with a clipon arrangement. Door and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of frame and shutter as a complete assembly including hardware. SD 02: 900x2100mm Wall opening size with VISION PANEL of Size 200 x 450mm as per Dwg. for SHAFT. The Hardware set for the Door are mentioned below: 1. Ball bearing butt hinge, SS304, of size 100 X 75 X 3mm with screws in SSS Homann 3 Nos 2. Mortise shaft lolck H7, 57mm BS, with Allen Key and escutcheons, sss Hormann 1 No 3. Flush handle, CH 120S, 120X40mm, SSS finish Hormann 4. Fire and Smoke seal C421 (Art. No. 315092), black Hormann Sales 5 Nos 5. Gasket, Fire rated 4mm Thick x 13mm , Black 4 Nos 6. Fire clear glass 6mm 200 X 300mm 1 No 7. Installation kit: Nylon Achor and other Misc items 1 no

58

9850

571300

... More
Man313 - RAILING WORK: Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineerin charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Lower Basement 01:

204

593

121023

... More
Man314 - RAILING WORK: Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineerin charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Ground Floor:

444

593

263403

... More
Man315 - RAILING WORK: Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineerin charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : First Floor:

204

599

122232.72

... More
Man316 - RAILING WORK: Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineerin charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Second Floor:

204

605

123454.68

... More
Man317 - RAILING WORK: Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineerin charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Third Floor:

204

611

124688.88

... More
Man318 - RAILING WORK: Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineerin charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Fourth Floor:

204

617

125935.32

... More
Man319 - Providing and fixing STAINLESS STEEL MATT FINISHED 304 GRADE for Staircase GRIP RAILINGS, balconies, ramps, with hand rail, 50mm dia 16 guage hollow pipe fixed to hollow 25mm dia pipe of 16 guage and welded to 100mm x 100mm x 6mm Thick S.S. plate as per drawing, stainless steel supporting pipe and Plates spaced at 1.20m regular intervals. The entire assembly is fixed to Wall or concrete by using expansion bolts of 8mm Dia by drilling etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Lower Basement 01:

46

1750

80500

... More
Man320 - Providing and fixing STAINLESS STEEL MATT FINISHED 304 GRADE for Staircase GRIP RAILINGS, balconies, ramps, with hand rail, 50mm dia 16 guage hollow pipe fixed to hollow 25mm dia pipe of 16 guage and welded to 100mm x 100mm x 6mm Thick S.S. plate as per drawing, stainless steel supporting pipe and Plates spaced at 1.20m regular intervals. The entire assembly is fixed to Wall or concrete by using expansion bolts of 8mm Dia by drilling etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Ground Floor:

44

1750

77000

... More
Man321 - Providing and fixing STAINLESS STEEL MATT FINISHED 304 GRADE for Staircase GRIP RAILINGS, balconies, ramps, with hand rail, 50mm dia 16 guage hollow pipe fixed to hollow 25mm dia pipe of 16 guage and welded to 100mm x 100mm x 6mm Thick S.S. plate as per drawing, stainless steel supporting pipe and Plates spaced at 1.20m regular intervals. The entire assembly is fixed to Wall or concrete by using expansion bolts of 8mm Dia by drilling etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: First Floor:

46

1750

80500

... More
Man322 - Providing and fixing STAINLESS STEEL MATT FINISHED 304 GRADE for Staircase GRIP RAILINGS, balconies, ramps, with hand rail, 50mm dia 16 guage hollow pipe fixed to hollow 25mm dia pipe of 16 guage and welded to 100mm x 100mm x 6mm Thick S.S. plate as per drawing, stainless steel supporting pipe and Plates spaced at 1.20m regular intervals. The entire assembly is fixed to Wall or concrete by using expansion bolts of 8mm Dia by drilling etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Second Floor:

52

1750

91000

... More
Man323 - Providing and fixing STAINLESS STEEL MATT FINISHED 304 GRADE for Staircase GRIP RAILINGS, balconies, ramps, with hand rail, 50mm dia 16 guage hollow pipe fixed to hollow 25mm dia pipe of 16 guage and welded to 100mm x 100mm x 6mm Thick S.S. plate as per drawing, stainless steel supporting pipe and Plates spaced at 1.20m regular intervals. The entire assembly is fixed to Wall or concrete by using expansion bolts of 8mm Dia by drilling etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Third Floor:

52

1750

91000

... More
Man324 - Providing and fixing STAINLESS STEEL MATT FINISHED 304 GRADE for Staircase GRIP RAILINGS, balconies, ramps, with hand rail, 50mm dia 16 guage hollow pipe fixed to hollow 25mm dia pipe of 16 guage and welded to 100mm x 100mm x 6mm Thick S.S. plate as per drawing, stainless steel supporting pipe and Plates spaced at 1.20m regular intervals. The entire assembly is fixed to Wall or concrete by using expansion bolts of 8mm Dia by drilling etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Fourth Floor:

52

1750

91000

... More
Man325 - Providing and fixing STAINLESS STEEL MATT FINISHED 304 GRADE for Staircase GRIP RAILINGS, balconies, ramps, with hand rail, 50mm dia 16 guage hollow pipe fixed to hollow 25mm dia pipe of 16 guage and welded to 100mm x 100mm x 6mm Thick S.S. plate as per drawing, stainless steel supporting pipe and Plates spaced at 1.20m regular intervals. The entire assembly is fixed to Wall or concrete by using expansion bolts of 8mm Dia by drilling etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Fifth Floor:

52

1750

91000

... More
Man326 - MISCELLANEOUS ITEMS: Toilet cubicles with door Providing and installing Cubicles as per the sizes mentioned in drawings of approved colour and pattern having cubicle height of 2000mm, cubicles made using solid grade high pressure laminate as per IS:2046 and EN 138, having scratch, abrasion, water resistance, heat, chemical, impact and moisture resistance with anti bacterial properties. All doors are single colour of 12mm thick compact HPL, each door supported by 3 SS hinges affixed to pilasters, SS Coat hook, SS door knob, all door will routed at the vertical ends and rubber sponge lining will be incorporated at the routed ends, Pilaster will be made of 12mm thick HPL with SS lock set ( comprised of thumb turn and occupancy indicator), pilaster will be anchored to floor with SS adjustable legs. all intermediate dividers partitions made of 12mm thick HPL affixed to SS U channel at their ends for stability, cubicle having accessories SS 304 grade top rail of size 55x42x1.6mm, SS Corner joinery section, Adjustable pedestal footing of 60mm dia SS 316 grade adjustable to 100150mm height, SS spring loaded butt hinges, SS coat hook with rubber stopper, SS round knob 30mm dia, SS rotating thumb knob locking system, anti noise rubber padding 2mm thk and 10mm wide, complete work at all levels and heights, lead, lift, scaffolding, clearing the debris, as directed by the Architects. ( MERINO TITAN STANDRAD Series or equivalent) : FOURTH FLOOR.

20

34500

690000

... More
Man327 - Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 30MPa as per IRC SP 63:2018 and IS 1565B over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and Usage charges of machinery complete as per specifications including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Specification No. KBS heavy duty cobble stones 75mm thick: (i). Ground Floor: (Level 02):

385

1219

469334.25

... More
Man328 - Providing and fixing M.S. Grill over existing compound wall as per using 16mm x 16mm M.S. Square rod at 150mm c c spacing and 6mm x 40mm M.S. flats at horizontal and 6mm x12mm M.S. flat for ornamental design and providing shop edge design at the vertex of every vertical rods, including welding, grinding wherever necessary. All the steel surface should be thoroughly cleaned free of rust and painted with anti corrosive paint (shop paint) etc., complete. The work includes cost of all materials, labour charges for all items of work, hire charges for welding, cutting and grinding equipment, and electricity charges, etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.

206

5637

1161314.7

... More
Man329 - Providing and fixing M.S. Gate as per Chief Architect Drawing, using 50mm x 50mm 14 guage M.S. hollow pipe frame work bent to ornamental shape as shown in the drawing and 35mm x 6mm and 16 x 16mm Square rods for verticals alternatively spaced at 4cms c c in two halves and 40mmx6mm M.S. flats for horizontal member and at the top cast iron spikes are provided at alternate vertical members as shown in the drawing etc., complete. All the steel surface should be thoroughly cleaned free of rust and painted with anti corrosive paint (shop paint) etc., complete. The work includes cost of all materials, labour charges for all items of work, hire charges for welding, cutting and grinding equipment, and electricity charges, with lead and lift, loading and unloading charges, etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.

36

3162

113853.6

... More
Man330 - Cast in Situ Cement Concrete M 20 Kerb with Channel: Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 15 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409: PCC M15 grade for kerb base

484

389

188542.2

... More
Man331 - Cast in Situ Cement Concrete M 20 Kerb with Channel: Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 15 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409: PCC M20 grade for kerb Cast in Situ

484

389

188542.2

... More
Man332 - Supplying and fixing M.S. Rectangular poles made out of 2 equal angles of 65x65x6 mm welded together and fixed in CC (1:2:4) WITH 2 NOS 16mm dia M.S. hold fast rods each of length 25 cms. Including cost of all materials cutting, bending scaffolding wherever necessary, nicely finishing the welded joints with all lead lifts and as per the directions of the Engineerin charge of the work and including providing 2 coats of approved quality paint over one coat of shop painting ( excluding cost of earthwork and concrete) including cost of materials, labour, HOM complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. including cost of materials, labour, HOM complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.

410

880

361189.5

... More
Man333 - Providing and fixing M.S. Block pipe of 38mm dia, of heavy guage of 14 including removing the bends, cutting the pipe, and fixing pipe in between the existing two verticle poles (M.S. rectangular poles) and spot welding the chain link with M.S. block pipe including cost of all materials wastage in cutting, and scaffolding wherever necessary with all lead and lift as directed by the Engineerincharge of work etc., complete including two coats of approved quality paint over one coat of shop paint, including cost of materials, labour, HOM complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. M.S. Block pipe of 38mm dia, of heavy guage of 14

60

428

25704

... More
Man334 - Chain Link Fencing: Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineerincharge. (Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade)including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.

25

883

22076.25

... More
Man335 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge.

375

142

53550

... More
Man336 - Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Single leaf door ofsize 3.00 m x2.40 m

14

4701

65826.6

... More
Man337 - PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. CEILING : Lower Basement 01

4205

105

441525

... More
Man338 - PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. CEILING : Ground Floor

3295

105

345975

... More
Man339 - PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. CEILING : First Floor

4090

106

433744.5

... More
Man340 - PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. CEILING : Second Floor

3395

107

363638.45

... More
Man341 - PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. CEILING : Third Floor

4080

108

441374.4

... More
Man342 - PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. CEILING : Fourth Floor

1970

109

215242.2

... More
Man343 - PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. CEILING : Fifth Floor

780

110

86073

... More
Man344 - PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. WALL:Lower Basement 01

1475

105

154875

... More
Man345 - PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. WALL: Ground Floor

3420

105

359100

... More
Man346 - PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. WALL: First Floor

3075

106

326103.75

... More
Man347 - PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. WALL: Second Floor

2815

107

301514.65

... More
Man348 - PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. WALL: Third Floor

2740

108

296413.2

... More
Man349 - PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. WALL: Fourth Floor

2000

109

218520

... More
Man350 - PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. WALL: Fifth Floor

1510

110

166628.5

... More
Man351 - 1. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Wall : Lower Basement 01

2005

171

343155.75

... More
Man352 - 1. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Wall : Ground Floor

3465

171

593034.75

... More
Man353 - 1. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Wall : First Floor

3075

172

531544.5

... More
Man354 - 1. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Wall : Second Floor

2815

174

491470.85

... More
Man355 - 1. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Wall : Third Floor

2740

176

483171.6

... More
Man356 - 1. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Wall : Fourth Floor

2000

178

356200

... More
Man357 - 1. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Wall : Fifth Floor

1510

179

271618.8

... More
Man358 - 1. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. CEILING painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. CEILING: Lower Basement 01

3675

171

628976.25

... More
Man359 - 1. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. CEILING painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. CEILING: Ground Floor

3250

171

556237.5

... More
Man360 - 1. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. CEILING painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. CEILING: First Floor

4090

172

706997.4

... More
Man361 - 1. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. CEILING painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. CEILING: Second Floor

3395

174

592733.05

... More
Man362 - 1. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. CEILING painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. CEILING: Third Floor

4080

176

719467.2

... More
Man363 - 1. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. CEILING painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. CEILING: Fourth Floor

1970

178

350857

... More
Man364 - 1. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. CEILING painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. CEILING: Fifth Floor

780

179

140306.4

... More
Man365 - Finishing walls with textured exterior paint of required shade :New work (Two coats applied at 3.28 ltr 10 m²) over and including priming coat of exterior primer applied at 2.20kg 10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Lower Basement 01

210

297

62401.5

... More
Man366 - Finishing walls with textured exterior paint of required shade :New work (Two coats applied at 3.28 ltr 10 m²) over and including priming coat of exterior primer applied at 2.20kg 10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Ground Floor

1257

297

373517.55

... More
Man367 - Finishing walls with textured exterior paint of required shade :New work (Two coats applied at 3.28 ltr 10 m²) over and including priming coat of exterior primer applied at 2.20kg 10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : First Floor

1205

300

361644.6

... More
Man368 - Finishing walls with textured exterior paint of required shade :New work (Two coats applied at 3.28 ltr 10 m²) over and including priming coat of exterior primer applied at 2.20kg 10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Second Floor

975

303

295542

... More
Man369 - Finishing walls with textured exterior paint of required shade :New work (Two coats applied at 3.28 ltr 10 m²) over and including priming coat of exterior primer applied at 2.20kg 10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Third Floor

915

306

280127.25

... More
Man370 - Finishing walls with textured exterior paint of required shade :New work (Two coats applied at 3.28 ltr 10 m²) over and including priming coat of exterior primer applied at 2.20kg 10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Fourth Floor

915

309

282927.15

... More
Man371 - Finishing walls with textured exterior paint of required shade :New work (Two coats applied at 3.28 ltr 10 m²) over and including priming coat of exterior primer applied at 2.20kg 10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Fifth Floor

915

312

285754.5

... More
Man372 - Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer incharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. (Shaft Internal): Lower Basement 01:

295

27

8053.5

... More
Man373 - Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer incharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. (Shaft Internal): Ground Floor:

580

27

15834

... More
Man374 - Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer incharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. (Shaft Internal): First Floor:

565

27

15577.05

... More
Man375 - Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer incharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. (Shaft Internal): SECOND FLOOR:

545

27

15178.25

... More
Man376 - Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer incharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. (Shaft Internal): THIRD FLOOR:

545

28

15330.85

... More
Man377 - Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer incharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. (Shaft Internal): FOURTH FLOOR:

545

28

15483.45

... More
Man378 - Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer incharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. (Shaft Internal): FIFTH FLOOR:

545

28

15636.05

... More
Man379 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerinchargeincluding cost of materials, labour, complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works at all Levels.

386

175

67685.1

... More
Man380 - Door Fixtures: Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. 125x70x4 mm (ordinary type)

456

178

81396

... More
Man381 - Providing and fixing bright finished brass flush bolts with necessary brass screws etc. complete : (a). 250 mm

20

257

5145

... More
Man382 - Providing and fixing bright finished brass flush bolts with necessary brass screws etc. complete : (b). 150 mm

20

222

4452

... More
Man383 - Providing and fixing bright finished brass flush bolts with necessary brass screws etc. complete : ( c). 100 mm

5

172

861

... More
Man384 - Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.

48

126

6048

... More
Man385 - Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.

77

1039

80041.5

... More
Man386 - Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

67

1104

74008.2

... More
Man387 - Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.

114

1169

133345.8

... More
Man388 - Providing and fixing chromium plated brass handles of 100 125 mm with necessary screws etc. complete

114

248

28368.9

... More
Man389 - Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (a). 200x10mm

70

367

25725

... More
Man390 - Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (b). 150x10mm

118

303

35807.1

... More
Man391 - Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm

134

261

35034.3

... More
Man392 - Providing and fixing Rectangular High Desnity Polyethylene water Storage Loft Tank with Cover, conforming to IS:12701, Colour of Opeque White or as approved by Engineerincharge. The rate includes making necessary holes for inlet, outlet and Over flow pipes. The base i c fittings and fixures for tank shall be paid seperately.

30000

9

283500

... More
Man393 - Providing and Fixing 2.5 Tonne Capacity Fiber Reinforced Polymer manhole cover (Recessed Type) of Size 600mm X 600mm X 33mm with locking arrangements including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.

15

6650

99750

... More
Man394 - Supply and Fixing of PVC Rungs OF 300mm wide for Foot Rest in Water Tank at 400 mm c c. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.

225

450

101250

... More
Man395 - Providing and fixing 450mm puddle flanges inside walls of water tank including making opening water tight complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : 150mm

6

3000

18000

... More
Man396 - Providing and fixing 450mm puddle flanges inside walls of water tank including making opening water tight complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : 100mm

6

2050

12300

... More
Man397 - Providing and fixing 450mm puddle flanges inside walls of water tank including making opening water tight complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : 80mm

6

1675

10050

... More
Man398 - Providing and fixing 450mm puddle flanges inside walls of water tank including making opening water tight complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : 63mm

6

1350

8100

... More
Man399 - Providing and fixing 450mm puddle flanges inside walls of water tank including making opening water tight complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : 50mm

6

1250

7500

... More
Man400 - Providing and fixing 450mm puddle flanges inside walls of water tank including making opening water tight complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : 32mm

6

900

5400

... More
Man401 - 1. Providing 12 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Water Proof Plastering Terrace and Coving) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (One Kg Bag of Cement) 3. Extra for making chequers of approved pattern on 1:2:4 cement concrete floors, steps, landing, pavements etc.

265

409

108525.45

... More
Man402 - 1. Providing 12 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Water Proof Plastering Terrace and Coving) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (One Kg Bag of Cement)

20

351

7035.6

... More
Man403 - Providing and constructing SAUCER DRAIN : 1. Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates 100mm Thick

18

1045

18826.56

... More
Man404 - 1. Providing 15mm cement plaster onr ough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kg per Bag of Cement] . For EXTERNAL PLASTERING: SUB STRUCTURE

187

337

63121.85

... More
Man405 - 1. Providing 12 mm cement plaster with cement mortar 1:3 (1 cement: 3 Fine sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Water Proof Plastering Floor) 2. Extra for providing and mixing water proofing materials in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement] (Water Proof Plastering FLOORS): SUB STRUCTURE (SEWAGE TREATMENT PLANT)

61

349

21335.97

... More
Man406 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. For FLAGGING

60

309

18585

... More
Man407 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (External Plastering)

41

366

15024.45

... More
Man408 - DOORS, WINDOWS: and VENTILATORS: Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. RED SAL WOOD FRAMES.

0.1

104580

10458

... More
Man409 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.

1

1066

1066.8

... More
Man410 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (partI) 1991. from manufacturer complete as per spcification. 40 mm thick both side Teak

3

4246

12738.6

... More
Man411 - Providing and fixing of 3track x 2panel sliding windows made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardwareand Multi point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor TandP s shall not be made) PARTLY FIXED AND PARTLY SLIDING: GROUND FLOOR :

13

7070

91919.1

... More
Man412 - 1. Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerincharge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2.Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge.

4

176

705.6

... More
Man413 - Providing and fixing 75mm thick 300 mm height and 1500 mm dia RCC ring with reinforcement using cement mortar 1:3 including all materials , labour , lead and lift, loading and unloading , scaffolding etc., complete including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.at all levels

40

1500

60000

... More
Man414 - Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine medium coarse, in required grading and sizes as per actual requirement, all complete as per direction of Engineerin charge.

5

1405

7029.75

... More
Man415 - Supplying, filling, spreading and leveling broken bricks of size range 15 cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineerincharge.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m including with all labour, all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works.

4

1200

4800

... More
Man416 - Sand Filling in Wells complete as per Drawing and Technical Specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.

3

2710

8130.15

... More
Man417 - Providing and Filling in foundation with granite trap broken metal 100mm and down size with approved MSand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.

3

2816

8448.3

... More
Man418 - Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4 : Pipes of SN4, 160mm dia.

50

604

30240

... More
Man419 - Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4 : Pipes of SN4, 110mm dia.

50

302

15120

... More
Man420 - Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and Form Work to be paid separately) M 20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 320 Kgs Cum]. Average 50 mm Thick.(Benching Concrete)

7

6639

46474.05

... More
Man421 - FACADE WORK: Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. GROUND FLOOR:

2630

142

375564

... More
Man422 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. At ALL LEVELS:

10500

147

1545180

... More
Man423 - Structural Glazing Work: Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved drawings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 6080 microns conforming to AAMA 2604 of required colour and shade as approved by the EngineerinCharge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.: Ground Floor:

2555

555

1419455.8

... More
Man424 - Structural Glazing Work: Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved drawings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 6080 microns conforming to AAMA 2604 of required colour and shade as approved by the EngineerinCharge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.: First Floor:

2590

561

1453300.8

... More
Man425 - Structural Glazing Work: Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved drawings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 6080 microns conforming to AAMA 2604 of required colour and shade as approved by the EngineerinCharge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.: Second Floor:

1540

566

872764.2

... More
Man426 - Structural Glazing Work: Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved drawings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 6080 microns conforming to AAMA 2604 of required colour and shade as approved by the EngineerinCharge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.: Third Floor:

1645

572

941598

... More
Man427 - Structural Glazing Work: Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved drawings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 6080 microns conforming to AAMA 2604 of required colour and shade as approved by the EngineerinCharge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.: Fourth Floor:

2870

578

1659204.4

... More
Man428 - Structural Glazing Work: Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved drawings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 6080 microns conforming to AAMA 2604 of required colour and shade as approved by the EngineerinCharge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.: Fifth Floor:

4340

583

2534126

... More
Man429 - Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis and design and preparation of shop drawings for the specified design loads conforming to IS 875 part III This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, TandP, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineerincharge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer inCharge. (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC masonry structural steel framework of building structure using stainless steel anchor fasteners bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c)Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d)Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. As per schedule B.

365

3665

1337735.95

... More
Man430 - Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis and design and preparation of shop drawings for the specified design loads conforming to IS 875 part III This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, TandP, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineerincharge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer inCharge. (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC masonry structural steel framework of building structure using stainless steel anchor fasteners bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c)Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d)Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. As per schedule B.

370

3701

1369621.6

... More
Man431 - Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis and design and preparation of shop drawings for the specified design loads conforming to IS 875 part III. As per schedule B.

220

3738

822514

... More
Man432 - Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis and design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC masonry structural steel framework of building structure using stainless steel anchor fasteners bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c)Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d)Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, TandP, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineerincharge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer inCharge. As per schedule B.

235

3776

887381.15

... More
Man433 - Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis and design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC masonry structural steel framework of building structure using stainless steel anchor fasteners bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c)Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d)Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, TandP, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineerincharge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer inCharge. As per schedule B.

410

3813

1563678.5

... More
Man434 - Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis and design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC masonry structural steel framework of building structure using stainless steel anchor fasteners bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c)Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d)Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, TandP, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineerincharge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer inCharge. As per schedule B.

620

3851

2388233.8

... More
Man435 - Providing, assembling and supplying vision glass panels (IGUs) comprising of hermeticallysealed 612 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the EngineerinCharge. The IGUs shall be assembled in the factory workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.250.28) and U value of 3.0 to 3.3 W m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside. Ground Floor:

364

4153

1511946.8

... More
Man436 - Providing, assembling and supplying vision glass panels (IGUs) comprising of hermeticallysealed 612 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the EngineerinCharge. The IGUs shall be assembled in the factory workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.250.28) and U value of 3.0 to 3.3 W m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.: FIRST FLOOR:

370

4195

1552238.8

... More
Man437 - Providing, assembling and supplying vision glass panels (IGUs) comprising of hermeticallysealed 612 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the EngineerinCharge. The IGUs shall be assembled in the factory workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.250.28) and U value of 3.0 to 3.3 W m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.:SECOND FLOOR:

220

4237

932181.8

... More
Man438 - Providing, assembling and supplying vision glass panels (IGUs) comprising of hermeticallysealed 612 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the EngineerinCharge. The IGUs shall be assembled in the factory workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.250.28) and U value of 3.0 to 3.3 W m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.:THIRD FLOOR:

235

4279

1005696.6

... More
Man439 - Providing, assembling and supplying vision glass panels (IGUs) comprising of hermeticallysealed 612 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the EngineerinCharge. The IGUs shall be assembled in the factory workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.250.28) and U value of 3.0 to 3.3 W m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.:FOURTH FLOOR:

410

4322

1772167.6

... More
Man440 - Providing, assembling and supplying vision glass panels (IGUs) comprising of hermeticallysealed 612 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the EngineerinCharge. The IGUs shall be assembled in the factory workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.250.28) and U value of 3.0 to 3.3 W m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.: FIFTH FLOOR:

620

4365

2706659.6

... More
Man441 - Extra for openable side top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Ground Floor:

95

5675

539188.65

... More
Man442 - Extra for openable side top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: First Floor:

95

5732

544580.85

... More
Man443 - Extra for openable side top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Second Floor:

55

5789

318436.25

... More
Man444 - Extra for openable side top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Third Floor:

60

5847

350859

... More
Man445 - Extra for openable side top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Fourth Floor:

105

5906

620143.65

... More
Man446 - Extra for openable side top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Fifth Floor:

155

5965

924604.45

... More
Man447 - Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi rigid, inorganic, noncombustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black nonwoven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g m2,made of randomly oriented glass fibres distributed in a binder by a wetlay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.: Ground Floor:

265

2646

701386.1

... More
Man448 - Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi rigid, inorganic, noncombustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black nonwoven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g m2,made of randomly oriented glass fibres distributed in a binder by a wetlay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.: First Floor:

280

2673

748498.8

... More
Man449 - Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi rigid, inorganic, noncombustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black nonwoven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g m2,made of randomly oriented glass fibres distributed in a binder by a wetlay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.: Second Floor:

450

2699

1214973

... More
Man450 - Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi rigid, inorganic, noncombustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black nonwoven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g m2,made of randomly oriented glass fibres distributed in a binder by a wetlay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.: Third Floor:

435

2726

1186218.9

... More
Man451 - Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi rigid, inorganic, noncombustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black nonwoven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g m2,made of randomly oriented glass fibres distributed in a binder by a wetlay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.: Fourth Floor:

370

2754

1019057.7

... More
Man452 - Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi rigid, inorganic, noncombustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black nonwoven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g m2,made of randomly oriented glass fibres distributed in a binder by a wetlay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.: Fifth Floor:

215

2781

598076.25

... More
Man453 - Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer in Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.25 0.28) and U value of 3.0 to 3.3 W m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.: Ground Floor:

265

2702

716215.5

... More
Man454 - Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer in Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.25 0.28) and U value of 3.0 to 3.3 W m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.: First Floor:

280

2729

764324.4

... More
Man455 - Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer in Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.25 0.28) and U value of 3.0 to 3.3 W m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.: Second Floor:

450

2757

1240663.5

... More
Man456 - Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer in Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.25 0.28) and U value of 3.0 to 3.3 W m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.: Third Floor:

435

2784

1211301

... More
Man457 - Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer in Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.25 0.28) and U value of 3.0 to 3.3 W m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.: Fourth Floor:

370

2812

1040606.5

... More
Man458 - Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer in Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.25 0.28) and U value of 3.0 to 3.3 W m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.: Fifth Floor:

215

2840

610722.55

... More
Man459 - Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick Rcc stone walls and coloumns beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick nonhalogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E11912 and clause B, S1, do as per ENT 135011sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion: Ground Floor:

100

5444

544499

... More
Man460 - Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick Rcc stone walls and coloumns beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick nonhalogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E11912 and clause B, S1, do as per ENT 135011sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion: First Floor:

100

5499

549944

... More
Man461 - Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick Rcc stone walls and coloumns beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick nonhalogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E11912 and clause B, S1, do as per ENT 135011sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion: Second Floor:

95

5554

527670.85

... More
Man462 - Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick Rcc stone walls and coloumns beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick nonhalogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E11912 and clause B, S1, do as per ENT 135011sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion: Third Floor:

95

5609

532947.15

... More
Man463 - Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick Rcc stone walls and coloumns beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick nonhalogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E11912 and clause B, S1, do as per ENT 135011sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion: Fourth Floor:

95

5666

538276.65

... More
Man464 - Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick Rcc stone walls and coloumns beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick nonhalogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E11912 and clause B, S1, do as per ENT 135011sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion: Fifth Floor:

225

5722

1287614.25

... More
Man465 - Design supply and installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (PartIII). The Suspended System held with Spider Fittings of SS316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS 316 Grade Stainless steel Spider and bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab beams by means of SS 316 Grade stainless steel brackets and Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener and anchor bolts, non staining weather sealants of approved make, Teflon nylon bushes and separators to prevent bimetallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion and seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter and in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof and dust proof. The rate shall include submission of all design, Engineering and shop drawing including getting approval from structural designer, labour, TandP, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : GROUND FLOOR:

175

10854

1899534

... More
Man466 - Design supply and installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (PartIII). The Suspended System held with Spider Fittings of SS316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS 316 Grade Stainless steel Spider and bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab beams by means of SS 316 Grade stainless steel brackets and Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener and anchor bolts, non staining weather sealants of approved make, Teflon nylon bushes and separators to prevent bimetallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion and seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter and in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof and dust proof. The rate shall include submission of all design, Engineering and shop drawing including getting approval from structural designer, labour, TandP, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : FIRST FLOOR:

145

10963

1589637.9

... More
Man467 - Providing, fabricating and fixing of Glazed canopy system as per detailed architectural drawing in required architectural profile as per approved shop drawings inclusive of glass panels as specified below, supporting system, subframe assembly profiles, accessories, necessary scaffolding staging, performance guarantee for a period of ten years as per approved format etc. complete as per manufacturer s specifications, approved shop drawings and as directed by the Engineer and as detailed hereunder : The supporting structure for canopy system shall be of MS hollow rectangular square tubular box sections conforming to IS 4923 or MS hot rolled single builtup sections conforming to IS : 2062 or medium heavy class MS hollow pipe sections conforming to IS: 1161 as approved by the Engineer. The joints of the rolled sections pipe junctions shall be welded as required with good quality of electrodes and finished smooth by grinding. The structural steel sections shall be finished with two coats of acrylic polyurethane painting over a coat of noncorrosive epoxy primer including surface preparation etc. The supporting structure shall be anchored with MS base plates MS angles to the main RCC steel structure using foundation plates and bolts or alternatively the members shall be embedded in the concrete wherever possible . The size of the glazed canopy panels shall be as specified in the detailed drawing or as approved by the Engineer. The length shall be made to order to minimize wastage. The Glass canopy will be fixed as per the detailed drawing. The entire system shall be completely water tight and shall include for colourless structural silicone sealants, weather seals, spacers, desiccants, fasteners, staging scaffolding etc. complete all as per approved shop drawings, technical specifications and as directed by the Engineer. Note : Structural Steel supporting system including painting over the steel sections shall be measured and paid separately. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.

110

18850

2073500

... More
Man468 - Funder Max Specification: Providing and fixing in position 6mm thk Century Ply s high density prelaminated exterior Cladding material in elevation at all locations straight or segmented as per the design and fixed to the aluminum MS frame work anchored with appropriate size anchor bolts screws in approved manner including providing scaffolding for the errection of the frame work, all materials, labour, cutting as per design instructions of the consulting engineer and architects including scaffolding, all materials, labour etc., complete

420

7500

3150000

... More
Man469 - ELECTRICAL WORK: HT PANELS: DAS RMU DAS Specification Compact RMU (VCB SF6 Type) as per IEC62271. The DAS RMUs shall have the following in addition to the Standards: DC motors, Numerical Relays, Multifunctional meters, fault passage indicator (FPI), Metering CTs, Protection CTs, Auxiliary transformers, Potential transformer, Batteries, Battery chargers (12V and 24V), AC power socket and light for illumination of Control panel. Control cable from each panel shall be wired and terminated to suitable 24 pin connectors in the control panel. Suitable space for fixing the Remote Terminal Unit (RTU) and Radio Modem in Control panel. Suitable clamps for fixing Antenna Pipe 3 Way RMU, 2OD + 1VL (One Incomer + One Breakers + One Outgoing) 630A with Copper Bus Bar.

1

827661

827661.45

... More
Man470 - METERING CUBICLE 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT and 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem and 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification. (Dwg No. BESCOM GM QSandS ....Dtd 24.11.2018) NOTE: CONTRACTOR TO OPERATE THIS ITEM, ONLY IF ELECTRICITY BOARD DO NOT SUPPLY THE SAME.

1

255645

255645.6

... More
Man471 - HT PANEL Conventional RMU (VCB Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC 62271 IS3427 One Breaker (VL) Panel with Copper Busbar

1

489260

489260.1

... More
Man472 - TRANSFORMERS Distribution Transformer 3 Phase, 11kV 433V Amorphous Core with Oil as per IS1180 (Part1): 2014 500 kVA, Aluminium Wdg, Star 2 (5 Star)

2

1023084

2046168.6

... More
Man473 - HT CABLES Supplying and laying of high tension 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS7098 (Part2) Armouring wires dia and Resistivity as per IS3975.: 240 Sqmm, (55 GI Wires 3.15 mm Dia).

0.2

2222957

444591.42

... More
Man474 - Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size: Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable: 3C x 240 Sq.mm

1

7698

7698.6

... More
Man475 - Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size: Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable : 3C x 240 Sq.mm

12

5703

68443.2

... More
Man476 - PARTB: LT ELECTRICAL WORK LT PANELS Supply, installation, testing and commissioning of cubicle type medium voltage switch boards as per specifications and comprising of ACB, MCCB, switch fuse unit etc., enclosed in M.S. cubicle complete with angle iron frame work, panel doors, horizontal and vertical busbars and outgoing feeders, bakelite separators, phase barriers, gaskets for door, feeders designations, etc., complete as per specifications. Main Switch Board shall be capable of withstanding 50 KA fault level. The panel shall be suitable for erection on the floor using channel and fastners at regular intervals. Fabricating supplying and mounting MS box made out ....SWG suitable for floor wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., 14 SWG

18000

-

9540

... More
Man477 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic FRP DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100 A 4 x 30 x 6 mm Aluminium Strips Typical Lighting Floor Panel (Total 6 Nos) Basement Floor SMSB Panel 1 Nos Lift Panel 1 Nos UPS Panel 2 Nos (Total 10 Nos)

20

2588

51765

... More
Man478 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic FRP DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips Typical Power Floor Panel (Total 6 Nos) As Incomer MUPS Panel 1 (Total 7 Nos)

12

3606

43281

... More
Man479 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic FRP DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 400 A 4 x 50 x 10 mm Aluminium Strips

2

4667

9334.5

... More
Man480 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic FRP DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 600 A 4 x 75 x 10 mm Aluminium Strips ACCP Panel 1 Nos

2

5906

11812.5

... More
Man481 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic FRP DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 1000 A double run of 4 x 60 x 10 mm Aluminium Strips LT Panel 1 Nos

50

11109

555450

... More
Man482 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mm

60

582

34965

... More
Man483 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 150 x 75 x 6 mm C channel.

10

972

9723

... More
Man484 - 11 kV CT : Indoor Outdoor.: 11 kV CT : 1200800 111 A (for Incomer Bus Coupler of 25 kA SWG) : OUTDOOR

2

59713

119427

... More
Man485 - 11 kV CT : Indoor Outdoor.: 11 kV CT : 800400 111 A (for Incomer Bus Coupler of 25 kA SWG ) : INDOOR

2

38115

76230

... More
Man486 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON OFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5063 A TPN For TVSS Connectivity

1

3242

3242.4

... More
Man487 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230 440VAC. 50 Hz 12 24V D.C.

24

540

12978

... More
Man488 - Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel wood board.

4

474

1898.4

... More
Man489 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay auto manual reset facility suitable to mount on DIN rail flush mounting on panel board.

4

9717

38871

... More
Man490 - Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy

4

9780

39123

... More
Man491 - Supplying, fixing and wiring rotary selector switch suitable for Voltmeter

2

168

336

... More
Man492 - Supplying, fixing and wiring 3 Phase Digital Ammeter Voltmeter

4

1496

5985

... More
Man493 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON OFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. As Isolator 5063 A TPN

2

3242

6484.8

... More
Man494 - LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 10 Sqmm, 4 Core, (10 GI Strips 4 x 0.8 mm)

5.02

156042

783333.852

... More
Man495 - LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 25 Sqmm, 4 Core, (13 GI Strips 4 x 0.8 mm)

0.36

252853

91027.314

... More
Man496 - LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 50 Sqmm, 4 Core, (17 GI Strips 4 x 0.8 mm)

0.03

311550

9346.5225

... More
Man497 - LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 95 Sqmm, 3.5 Core, (21 GI Strips 4 x 0.8 mm)

0.57

539742

307652.94

... More
Man498 - LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 120 Sqmm, 3.5 Core, (23 GI Strips 4 x 0.8 mm)

0.65

664451

431893.5075

... More
Man499 - LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 240 Sqmm, 3.5 Core, (30 GI Strips 4 x 0.8 mm)

0.16

1245374

199259.928

... More
Man500 - LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 25 Sqmm, 3.5 Core, (12 GI Strips 4 x 0.8 mm)

0.25

190524

47631.15

... More
Man501 - LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.:50 Sqmm, 3.5 Core, (16 GI Strips 4 x 0.8 mm)

0.5

254531

127265.775

... More
Man502 - LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 70 Sqmm, 3.5 Core, (18 GI Strips 4 x 0.8 mm)

0.03

444855

13345.668

... More
Man503 - LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 95 Sqmm, 3.5 Core, (21 GI Strips 4 x 0.8 mm)

0.11

539742

59371.62

... More
Man504 - LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 185 Sqmm, 3.5 Core, (28 GI Strips 4 x 0.8 mm)

0.06

725778

43546.734

... More
Man505 - LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 300 Sqmm, 3.5 Core, (32 GI Strips 4 x 0.8 mm)

0.2

1119314

223862.94

... More
Man506 - LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 400 Sqmm, 3.5 Core, (39 GI Strips 4 x 0.8 mm)

0.3

1526142

457842.735

... More
Man507 - LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 3C 10 Sq.mm 2XWY (Copper)

0.01

379000

3790

... More
Man508 - LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 2C 16 Sq.mm 2XWY (Copper)

0.21

395000

82950

... More
Man509 - LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 1C 16 Sq.mm 2XWY (Copper)

0.14

195000

27300

... More
Man510 - LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 4 C 6 Sq.mm (Copper)

0.11

171517

18866.925

... More
Man511 - LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 4 Core 10 Sq mm (Copper)

0.01

280612

2806.125

... More
Man512 - 4C 16 Sq.mm. flexible multicore with copper conductor, PVC insulated, PVC shealthed Cable

210

661

138810

... More
Man513 - 4C 25Sq.mm. flexible multicore with copper conductor, PVC insulated, PVC shealthed Cable

26

1133

29458

... More
Man514 - 1C 10 Sq.mm flexible single core cable with annealed copper conductor, PVC insulated, PVC unsheathed cable

5

96

480

... More
Man515 - 1C 25 Sq.mm flexible single core cable with annealed copper conductor, PVC insulated, PVC unsheathed cable

5

235

1175

... More
Man516 - 1C 95 Sq.mm flexible single core cable with annealed copper conductor, PVC insulated, PVC unsheathed cable

231

894

206514

... More
Man517 - Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 81301984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS694:1990: 3C x 2.5 Sq.mm.

1103

118

130870.95

... More
Man518 - Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 81301984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS694:1990: 3C x 4 Sq.mm.

788

180

142312.8

... More
Man519 - 12 C - 2.5 Sq.mm YFY (Copper)

74

350

25900

... More
Man520 - 24 C - 2.5 Sq.mm YFY (Copper)

158

525

82950

... More
Man521 - LAYING CHARGES FOR CABLES Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe stoneware pipe on wall on pole as required. In existing trench duct. 2.5 sqmm to 25 sqmm

4.96

21930

108774.288

... More
Man522 - LAYING CHARGES FOR CABLES Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe stoneware pipe on wall on pole as required. In existing trench duct. 35 sqmm to 95 sqmm

1.12

32695

36619.464

... More
Man523 - LAYING CHARGES FOR CABLES Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe stoneware pipe on wall on pole as required. In existing trench duct. 120 sqmm to 240 sqmm

0.91

33891

30841.629

... More
Man524 - LAYING CHARGES FOR CABLES Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe stoneware pipe on wall on pole as required. In existing trench duct. 300sqmm 400 Sqmm

0.3

35884

10765.44

... More
Man525 - END TERMINATION Supplying and making end termination with brass Double compression gland and Copper lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1 KV grade as required.: Heavy Duty Copper Terminal Long Barrel 3C 2.5 Sq.mm

30

100

3024

... More
Man526 - END TERMINATION Supplying and making end termination with brass Double compression gland and Copper lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1 KV grade as required.: Heavy Duty Copper Terminal Long Barrel 3C 4 Sq.mm

40

110

4410

... More
Man527 - END TERMINATION Supplying and making end termination with brass Double compression gland and Copper lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1 KV grade as required.: Heavy Duty Copper Terminal Long Barrel 3C -6 Sq.mm

2

93

186.9

... More
Man528 - END TERMINATION Supplying and making end termination with brass Double compression gland and Copper lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1 KV grade as required.: Heavy Duty Copper Terminal Long Barrel 3C -10 Sq.mm

2

113

226.8

... More
Man529 - END TERMINATION Supplying and making end termination with brass Double compression gland and Copper lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1 KV grade as required.: Heavy Duty Copper Terminal Long Barrel 2C -16 Sq.mm

16

148

2383.52

... More
Man530 - END TERMINATION Supplying and making end termination with brass Double compression gland and Copper lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1 KV grade as required.: Heavy Duty Copper Terminal Long Barrel 4 C -6 Sq.mm

120

100

12096

... More
Man531 - END TERMINATION Supplying and making end termination with brass Double compression gland and Copper lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1 KV grade as required.: Heavy Duty Copper Terminal Long Barrel 4C 10 Sq.mm.

80

121

9744

... More
Man532 - END TERMINATION Supplying and making end termination with brass Double compression gland and Copper lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1 KV grade as required.: Heavy Duty Copper Terminal Long Barrel 4C 16 Sq.mm.

20

175

3502

... More
Man533 - Heavy Duty Copper Terminal Long Barrel: 25 Sqmm Copper Terminal, Apprx Wt: 11 Gm: 4C

20

236

4725

... More
Man534 - Heavy Duty Copper Terminal Long Barrel: 50 Sqmm Copper Terminal, Apprx Wt: 26 Gm: 4C

28

366

10260.6

... More
Man535 - Heavy Duty Copper Terminal Long Barrel: 70 Sqmm Copper Terminal, Apprx Wt: 38 Gm: 4C

2

577

1155

... More
Man536 - Heavy Duty Copper Terminal Long Barrel: 95 Sqmm Copper Terminal, Apprx Wt: 58 Gm: 4C

18

745

13419

... More
Man537 - Heavy Duty Copper Terminal Long Barrel: 120 Sqmm Copper Terminal, Apprx Wt: 64 Gm: 4C

12

855

10269

... More
Man538 - Heavy Duty Copper Terminal Long Barrel: 185 Sqmm Copper Terminal, Apprx Wt: 158 Gm: 4C

2

1279

2559.9

... More
Man539 - Heavy Duty Copper Terminal Long Barrel: 240 Sqmm Copper Terminal, Apprx Wt: 218 Gm: 3.5C

4

1898

7593.6

... More
Man540 - Heavy Duty Copper Terminal Long Barrel: 300 Sqmm Copper Terminal : 3.5C

12

2683

32205.6

... More
Man541 - Heavy Duty Copper Terminal Long Barrel: 400 Sqmm Copper Terminal, Apprx Wt: 395 Gm : 3 1/2 C

6

4637

27827.1

... More
Man542 - Aluminium End Terminal (Lug): 10 Sq.mm : 1 C

20

90

1806

... More
Man543 - Aluminium End Terminal (Lug): 16 Sq.mm : 1 C

40

90

3612

... More
Man544 - Aluminium End Terminal (Lug): 95 Sq.mm : 1 C

18

219

3950.1

... More
Man545 - 12 C -2.5 Sq.mm YFY (Copper)

4

107

429.76

... More
Man546 - 24 C -2.5 Sq.mm YFY (Copper)

4

144

579.52

... More
Man547 - CABLE TRAY (PERFORATED TYPE) Supplying and installing 2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts nuts and washer or welding as required. etc with all accessories like bends, reducers, Tee s, cross members, etc. complete as required. 150 x 50 mm

473

486

229948.95

... More
Man548 - CABLE TRAY (PERFORATED TYPE) Supplying and installing 2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts nuts and washer or welding as required. etc with all accessories like bends, reducers, Tee s, cross members, etc. complete as required. 300 x 50 mm

200

616

123270

... More
Man549 - CABLE TRAY (LADDER TYPE) Supply and erection of the following sizes of prefabricated, factory assembled, bottled rung type ladder trays made out of 2mm thick Pre galvanised steel runners and slotted rungs at every 300mm interval, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc with all accessories like bends, reducers, Tee s, cross members, etc. complete as required. 150 mm x 50mm

420

270

113400

... More
Man550 - CABLE TRAY (LADDER TYPE) Supply and erection of the following sizes of prefabricated, factory assembled, bottled rung type ladder trays made out of 2mm thick Pre galvanised steel runners and slotted rungs at every 300mm interval, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc with all accessories like bends, reducers, Tee s, cross members, etc. complete as required. 250 mm x 50mm

158

375

59250

... More
Man551 - CABLE TRAY (LADDER TYPE) Supply and erection of the following sizes of prefabricated, factory assembled, bottled rung type ladder trays made out of 2mm thick Pre galvanised steel runners and slotted rungs at every 300mm interval, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc with all accessories like bends, reducers, Tee s, cross members, etc. complete as required. 300 mm x 50mm

131

430

56330

... More
Man552 - CABLE TRAY (LADDER TYPE) Supply and erection of the following sizes of prefabricated, factory assembled, bottled rung type ladder trays made out of 2mm thick Pre galvanised steel runners and slotted rungs at every 300mm interval, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc with all accessories like bends, reducers, Tee s, cross members, etc. complete as required. 450 mm x 75mm

26

475

12350

... More
Man553 - CABLE TRAY (LADDER TYPE) Supply and erection of the following sizes of prefabricated, factory assembled, bottled rung type ladder trays made out of 2mm thick Pre galvanised steel runners and slotted rungs at every 300mm interval, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc with all accessories like bends, reducers, Tee s, cross members, etc. complete as required. 600 mm x 75mm

63

962

60606

... More
Man554 - MCB and MCCB Distribution BoardS, MCCB, MCB and ELMCB Supplying and fixing regular MCB distribution boards on wall ood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB s single phase 3 phase single door with powder coated painting Made out of 14 SWG MS enclosure. 8 Way SPN MCB DB

14

1566

21932.4

... More
Man555 - MCB and MCCB Distribution BoardS, MCCB, MCB and ELMCB Supplying and fixing regular MCB distribution boards on wall ood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB s single phase 3 phase single door with powder coated painting Made out of 14 SWG MS enclosure. 12 Way SPN MCB DB

15

1956

29342.25

... More
Man556 - MCB and MCCB Distribution BoardS, MCCB, MCB and ELMCB Supplying and fixing regular MCB distribution boards on wall ood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB s single phase 3 phase single door with powder coated painting Made out of 14 SWG MS enclosure. 16 Way SPN MCB DB

23

3078

70807.8

... More
Man557 - MCB and MCCB Distribution BoardS, MCCB, MCB and ELMCB Supplying and fixing regular MCB distribution boards on wall ood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB s single phase 3 phase single door with powder coated painting Made out of 14 SWG MS enclosure. 4 Way TPN MCB DB

1

4239

4239.9

... More
Man558 - MCB and MCCB Distribution BoardS, MCCB, MCB and ELMCB Supplying and fixing regular MCB distribution boards on wall ood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB s single phase 3 phase single door with powder coated painting Made out of 14 SWG MS enclosure. 6 Way TPN MCB DB

15

5187

77805

... More
Man559 - MCB and MCCB Distribution BoardS, MCCB, MCB and ELMCB Supplying and fixing regular MCB distribution boards on wall ood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB s single phase 3 phase single door with powder coated painting Made out of 14 SWG MS enclosure. 8 Way TPN MCB DB

15

6395

95933.25

... More
Man560 - Supplying and fixing regular MCCB distribution Panel confirming to IS IEC 61439 3 and IK09 tested as per IS IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall wood board flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB s as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single three phase suitable capacity MCB s as outgoings confirming to IS IEC 60898 2.. 8WAY

1

13235

13235.25

... More
Man561 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall : 1 2 Way

17

144

2463.3

... More
Man562 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal PVC box.: 1 2 Modula

17

143

2445.45

... More
Man563 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as perIS IEC609472.(Icu=100percentlcs). In 4P MCCB, all Poles should have protection for ShortCicrcuit Over Load. For Microprocessor MCCB S Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 100 A 25 kA 1. Typical Lighting Floor Panel(Total 6 Nos) As Incomer 1 Nos 6 Nos. 2. Basement Floor SMSB Panel As Incomer 1 Nos. 3. Lift Panel As Incomer and Out Going 2 Nos. 4. LT Panel Out going Floor Lighting Panel 6 Nos ,PHE , STP, SMSB 1 Basement Floor,Lift Panel 10 Nos. 5. LT Panel Out going Spare 3 Nos.

22

8911

196049.7

... More
Man564 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as perIS IEC609472.(Icu=100percentlcs). In 4P MCCB, all Poles should have protection for ShortCicrcuit Over Load. For Microprocessor MCCB S Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 125 A 25 kA 1. ACCP Panel As Out goings 2 Nos. 2. MUPS Panel 1 Nos. 3. LT Panel Out going Spare 1 Nos.

4

10858

43432.2

... More
Man565 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as perIS IEC609472.(Icu=100percentlcs). In 4P MCCB, all Poles should have protection for ShortCicrcuit Over Load. For Microprocessor MCCB S Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA 1. LT Panel Out going Floor Power Panel 6 Nos and Fire Fighting Panel 7 Nos. 2. LT Panel Out going Spare1 Nos. 3. Typical Power Floor Panel(Total 6 Nos) As Incomer 1 Nos 6 Nos.

14

14119

197670.9

... More
Man566 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as perIS IEC609472.(Icu=100percentlcs). In 4P MCCB, all Poles should have protection for ShortCicrcuit Over Load. For Microprocessor MCCB S Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 25 kA 1. HVAC Panel as Incomer 1 Nos.

1

22460

22460.55

... More
Man567 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as perIS IEC609472.(Icu=100percentlcs). In 4P MCCB, all Poles should have protection for ShortCicrcuit Over Load. For Microprocessor MCCB S Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 200 A 36 kA 1. LT Panel Out going AC1,2,3 3 Nos. 2. LT Panel Out going UPS 1 and 2 2 Nos. 3. LT Panel Out going Spare 2 Nos.

7

22495

157466.4

... More
Man568 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as perIS IEC609472.(Icu=100percentlcs). In 4P MCCB, all Poles should have protection for ShortCicrcuit Over Load. For Microprocessor MCCB S Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 36 kA 1. LT Panel Out going HVAC Panel 1 Nos.

1

24722

24722.25

... More
Man569 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as perIS IEC609472.(Icu=100percentlcs). In 4P MCCB, all Poles should have protection for ShortCicrcuit Over Load. For Microprocessor MCCB S Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 400 A 36 kA 1. ACCP Panel As Incomer 1 Nos.

1

29626

29626.8

... More
Man570 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as perIS IEC609472.(Icu=100percentlcs). In 4P MCCB, all Poles should have protection for ShortCicrcuit Over Load. For Microprocessor MCCB S Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 320400 A 50 kA 1. DG Incomer to Breaker Panel and Outgoings to LT Panel 5 Nos. 2. LT Panel Out going ACCP Panel 1 Nos.

6

31616

189699.3

... More
Man571 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as perIS IEC609472.(Icu=100percentlcs). In 4P MCCB, all Poles should have protection for ShortCicrcuit Over Load. For Microprocessor MCCB S Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 400500 A 50 kA 1. ACCP Panel As Out goings

1

43571

43571.85

... More
Man572 - Supplying and fixing of Shunt trip suitable for MCCB.CBCT 1. Basement Floor SMSB Panel As Out goings

3

1788

5364.45

... More
Man573 - RCCBs: Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240 450V upto 300mA sensitivity on existing wood panel board. 16A25A 2 pole

33

4490

148198.05

... More
Man574 - RCCBs: Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240 450V upto 300mA sensitivity on existing wood panel board. 3240A 2 pole

26

4786

124460.7

... More
Man575 - RCCBs: Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240 450V upto 300mA sensitivity on existing wood panel board. 63 A 2 pole

3

5520

16562.7

... More
Man576 - RCCBs: Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240 450V upto 300mA sensitivity on existing wood panel board. 1625A 4 pole

1

5319

5319.3

... More
Man577 - Supply and fixing of 3pole Capacitor switching contactor with NO NC contacts and inbuilt damping resistor to protect the contactor and capacitor from highest in rush current, fixed on existing wood panel board using necessary bolts, nuts, washers and wiring etc., complete with AC690V Rating operational voltage, 50HZ frequency and as per IS 6094741. 12.5 KVAR: ACCP Panel

4

3046

12184.2

... More
Man578 - Supply and fixing of 3pole Capacitor switching contactor with NO NC contacts and inbuilt damping resistor to protect the contactor and capacitor from highest in rush current, fixed on existing wood panel board using necessary bolts, nuts, washers and wiring etc., complete with AC690V Rating operational voltage, 50HZ frequency and as per IS 6094741. 30 KVAR : ACCP Panel

1

5527

5527.2

... More
Man579 - Supply and fixing of 3pole Capacitor switching contactor with NO NC contacts and inbuilt damping resistor to protect the contactor and capacitor from highest in rush current, fixed on existing wood panel board using necessary bolts, nuts, washers and wiring etc., complete with AC690V Rating operational voltage, 50HZ frequency and as per IS 6094741. 50 KVAR : ACCP Panel

2

15820

31640.7

... More
Man580 - SUB MAIN CIRCUIT CIRCUIT MAINS Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.0 Sq.mm

5000

19

99750

... More
Man581 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 Sq.mm

7000

27

191100

... More
Man582 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 Sq.mm

17000

44

749700

... More
Man583 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 Sq.mm

20000

66

1323000

... More
Man584 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 6 Sq.mm

8000

96

772800

... More
Man585 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 10 Sq.mm

250

175

43837.5

... More
Man586 - Supplying heavy gauge PVC Conduit Pipe....dia.......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hook sand cement plastering upto the wall surface and run with18SWG GI fish wire run throughout the conduit wherever necessary. 19 20mm dia 2mm thick

13500

71

963900

... More
Man587 - Supplying heavy gauge PVC Conduit Pipe....dia.......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hook sand cement plastering upto the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary. 25mm dia 2mm thick

20000

82

1659000

... More
Man588 - Supplying heavy gauge PVC Conduit Pipe....dia.......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hook sand cement plastering upto the wall surface and run with18SWG GI fish wire run throughout the conduit wherever necessary. 32mm dia 2.5mm thick

9750

103

1013512.5

... More
Man589 - Supplying heavy gauge PVC Conduit Pipe....dia.......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hook sand cement plastering upto the wall surface and run with18SWG GI fish wire run throughout the conduit wherever necessary. 40mm dia 2.5mm thick

200

145

29190

... More
Man590 - OPEN CONDUIT SYSTEM Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19 20 mm dia 2 mm thick.

5000

72

362250

... More
Man591 - OPEN CONDUIT SYSTEM Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick.

1450

85

123322.5

... More
Man592 - OPEN CONDUIT SYSTEM Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32 mm dia 2.5mm thick.

350

111

38955

... More
Man593 - OPEN CONDUIT SYSTEM Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 40 mm dia 2.5mm thick.

75

156

11733.75

... More
Man594 - Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 19 20 mm dia 2 mm thick

15000

69

1039500

... More
Man595 - Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 25 mm dia 2 mm thick.

18000

81

1474200

... More
Man596 - Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 32 mm dia 2.5mm thick.

1000

108

108150

... More
Man597 - Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 40 mm dia 2.5mm thick.

1000

154

154350

... More
Man598 - POINT WIRING: PRIMARY POINT (Long Points) Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5 Sqmm (PhaseandNeutral) and 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS694: and latest amendments) without control switch shall be fixed on the existing plastic sheet gang box ,the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch box Note: 1) Rates for all the point wiring items are inclusive of necessary circuit mains from the distribution board to the first switch board and also sub circuits from one switch board to the subsequent switch boards in the same circuit. 2) All the Chases made in the wall, ceiling, etc., at the time of laying of conduits shall be filled up neatly after erection of conduit.

1300

582

757575

... More
Man599 - SECONDARY POINT (MEDIUM POINT) Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5 Sqmm (PhaseandNeutral) and 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS694: and latest amendments) without control switch shall be fixed on the existing plastic sheet gang box ,the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch box Note: 1) Rates for all the point wiring items are inclusive of necessary circuit mains from the distribution board to the first switch board and also sub circuits from one switch board to the subsequent switch boards in the same circuit. 2) All the Chases made in the wall, ceiling, etc., at the time of laying of conduits shall be filled up neatly after erection of conduit.

1000

397

397950

... More
Man600 - SECONDARY POINT (Short Points) Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5 Sqmm (PhaseandNeutral) and 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS694: and latest amendments) without control switch shall be fixed on the existing plastic sheet gang box ,the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box Note: 1) Rates for all the point wiring items are inclusive of necessary circuit mains from the distribution board to the first switch board and also sub circuits from one switch board to the subsequent switch boards in the same circuit. 2) All the Chases made in the wall, ceiling, etc., at the time of laying of conduits shall be filled up neatly after erection of conduit.

250

282

70612.5

... More
Man601 - Supplying and fixing PVC metal conduit Deep junction box 19 20 mm deep Junction box

900

51

46305

... More
Man602 - SECONDARY POINT (Short Points) Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5 Sqmm (PhaseandNeutral) and 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS694: and latest amendments) without control switch shall be fixed on the existing plastic sheet gang box ,the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box Note: 1) Rates for all the point wiring items are inclusive of necessary circuit mains from the distribution board to the first switch board and also sub circuits from one switch board to the subsequent switch boards in the same circuit. 2) All the Chases made in the wall, ceiling, etc., at the time of laying of conduits shall be filled up neatly after erection of conduit. Supplying and fixing PVC metal conduit Deep junction box 25 mm deep Junction box

800

58

47040

... More
Man603 - SECONDARY POINT (Short Points) Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5 Sqmm (PhaseandNeutral) and 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS694: and latest amendments) without control switch shall be fixed on the existing plastic sheet gang box ,the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box Note: 1) Rates for all the point wiring items are inclusive of necessary circuit mains from the distribution board to the first switch board and also sub circuits from one switch board to the subsequent switch boards in the same circuit. 2) All the Chases made in the wall, ceiling, etc., at the time of laying of conduits shall be filled up neatly after erection of conduit. Supplying and fixing PVC metal conduit Deep junction box 32 mm deep Junction box

800

64

51240

... More
Man604 - CEILING FAN POINT Supplying of Ceiling Fan with Capacitor rating As per guide line of BEE 5 star rating and IS:374 19 and also comply with IS:1709 1984 with latest amendment, Rated voltage 220V 50Hz, Rated power upto 35W+ 10percent, Rated current As per IS:374 19, Rated power factor 0.9 lagging (min), Rated speed 350+ 10percentRPM, Ratedairdelivery210+ 10percentCubicMeter Minimum, Rated service value 6.2 CMM W, Three Blades of blade leaf 1.05mm thick Aluminium Alloy sheet, ClassB motor insulation, Bearing Two ball bearings, Top6202, Bottom6201, as per IS specification, Motor winding. Temprise Shall not exceed 75deg Cover and ambient of 400C by resistance method at 245V, Insulation resistance Shall not be less than Two Mega Ohms (2MOhms), Leakage current Should not exceed 210Micro Amp, Power input, Wandcurrent, Air Delivery and Fan Speed as per IS:374 2019 with latest amendment, 2 year manufacturer Warranty. (BLDC fans) 48inches Sweep 5 Star (1200 mm) Note: In case of roof slab MS rod inchesUinches hooks shall be provided in place of fan hook box.

70

2810

196759.5

... More
Man605 - Fixing a ceiling Wall mounting fan of all capacities and all types to the existing Sinches hook with fan regulator to the existing board to gether with supplying and fixing 5A. ceiling rose, necessary length of 23 0.0076 inch PVC insulated twin twisted copper wire and wiring.

105

179

18852.75

... More
Man606 - EXHAUST FAN POINT Supplyingof1440rpmheavydutyexhaustfanwithbracketbladessuitable to operate on 230V 50Hz, AC Supply complete. 12inches Sweep (300 mm)

11

3117

34291.95

... More
Man607 - Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5A, ceiling rose with sufficient length of 23 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.

11

742

8165.85

... More
Man608 - TWO WAY STAIRCASE LIGHT POINT Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.

15

174

2614.5

... More
Man609 - BUZZER POINT Supplying And fixing replacing of 6 16 32A electrical accessories on existing switch board. 6A Bell Buzzer

10

136

1365

... More
Man610 - SWITCHES, SOCKETS and ACCESSORIES: Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall, including necessary rawl plugs, Machine NF screws etc., complete. 12 Way

10

108

1081.5

... More
Man611 - SWITCHES, SOCKETS and ACCESSORIES: Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall, including necessary rawl plugs, Machine NF screws etc., complete. 3 Way

50

130

6510

... More
Man612 - SWITCHES, SOCKETS and ACCESSORIES: Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall, including necessary rawl plugs, Machine NF screws etc., complete. 45 Way

75

143

10788.75

... More
Man613 - SWITCHES, SOCKETS and ACCESSORIES: Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall, including necessary rawl plugs, Machine NF screws etc., complete. 6 Way

75

181

13623.75

... More
Man614 - SWITCHES, SOCKETS and ACCESSORIES: Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall, including necessary rawl plugs, Machine NF screws etc., complete. 8 Way

100

229

22995

... More
Man615 - SWITCHES, SOCKETS and ACCESSORIES: Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall, including necessary rawl plugs, Machine NF screws etc., complete. 1012 Way

100

274

27405

... More
Man616 - SWITCHES, SOCKETS and ACCESSORIES: Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall, including necessary rawl plugs, Machine NF screws etc., complete. 16 Way

100

308

30870

... More
Man617 - SWITCHES, SOCKETS and ACCESSORIES: Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall, including necessary rawl plugs, Machine NF screws etc., complete. 18 Way

20

355

7119

... More
Man618 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall. 12 Way

10

144

1449

... More
Man619 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall. 3 Way

50

166

8347.5

... More
Man620 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall. 4 5 Way

75

185

13938.75

... More
Man621 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall. 6 Way

75

231

17325

... More
Man622 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall. 8 Way

100

274

27405

... More
Man623 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall. 1012 Way

100

334

33495

... More
Man624 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall. 16 Way

100

381

38115

... More
Man625 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall. 18 Way

20

425

8505

... More
Man626 - 6A One Way Switch

700

107

74970

... More
Man627 - 6A Two Way Switch

20

174

3486

... More
Man628 - 6 16A Universal Socket

500

247

123900

... More
Man629 - TV Telephone Socket

100

163

16380

... More
Man630 - RJ45 I.O Outlet Cat6

50

353

17692.5

... More
Man631 - 6A Bell Push

25

185

4646.25

... More
Man632 - Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required.

188

42

7896

... More
Man633 - WIRE WAYS and RACEWAYS Supply and laying of under floor junction boxes shall be of threepiece construction -Base box, frame and load plate. Base box shall be robust in its construction manufactured from 1.5 mm thick zero spangle pre galvanized sheet steel with 275 GSM ( 36.67 microns) coating mass. The load plate and frame thicknesses shall be 3 mm and 2 mm respectively to provide adequate load bearing capacity of 5 kN with deflection not greater than 6mm while loading and permanent deflection not exceeding 3 mm as per EN 5008522. The trap and frame shall be Epoxy coated to protect from corrosion. The junction boxes shall be 10 mm or 20 mm recess to accommodate floor covering suitable for Tile Carpet marble granite according to site conditions. The junction box has height of 60mm up to finished floor level. The base of junction boxes should have prepunched sealing arrangements on all four sides to accept either 25 mm or 38 mm of metal raceways. For (50100x38mm) duct. Dimensions: 172x172x60mm. 10 mm Recess

10

1822

18228

... More
Man634 - WIRE WAYS and RACEWAYS Supply and laying of of RFT raised floor trunking systemJunction, for raised Flooring For (50100x38mm) duct. Dimensions: 170 mm x 170 mm x 56mm

10

1376

13765.5

... More
Man635 - Supply and laying of underfloor (concealed) raceways manufactured from 1.5 mm thick cover and base (including partitions for multi compartment raceways), zero spangle pregalvanized sheet steel with 275 GSM ( 36.67 microns) coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 5008522. 50 x 38mm

75

662

49691.25

... More
Man636 - Supply and laying of underfloor (concealed) raceways manufactured from 1.5 mm thick cover and base (including partitions for multi compartment raceways), zero spangle pregalvanized sheet steel with 275 GSM ( 36.67 microns) coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 5008522. 100 x 38mm

150

937

140647.5

... More
Man637 - Supply and laying of underfloor (concealed) raceways manufactured from 1.5 mm thick cover and base (including partitions for multi compartment raceways), zero spangle pregalvanized sheet steel with 275 GSM ( 36.67 microns) coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 5008522. 150 x 38mm

150

1587

238140

... More
Man638 - Supply and laying of underfloor (concealed) raceways manufactured from 1.5 mm thick cover and base (including partitions for multi compartment raceways), zero spangle pregalvanized sheet steel with 275 GSM ( 36.67 microns) coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 5008522. 200 x 38mm

26

2268

58968

... More
Man639 - Supply and laying of underfloor (concealed) raceways manufactured from 1.5 mm thick cover and base (including partitions for multi compartment raceways), zero spangle pregalvanized sheet steel with 275 GSM ( 36.67 microns) coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 5008522. 300 x 38mm

68

3213

218484

... More
Man640 - Supply and Installation of pregalvanised factory made junction boxes with 3.15mm thick cover plate and with counter sunk type screws of following sizes. The JBs Side plates shall be suitable for fixing metal and PVC raceways and knockouts to fit 20 25 32mm conduit entry. For (50100x38mm) duct.Dimensions:172x172x60mm. 10 mm Recess

100

1822

182280

... More
Man641 - Supply and Installation of pregalvanised factory made junction boxes with 3.15mm thick cover plate and with counter sunk type screws of following sizes. The JBs Side plates shall be suitable for fixing metal and PVC raceways and knockouts to fit 20 25 32mm conduit entry. For (50200x38mm) duct.Dimensions:272x272x60mm. 10 mm Recess

150

2678

401782.5

... More
Man642 - Supply and Installation of pregalvanised factory made junction boxes with 3.15mm thick cover plate and with counter sunk type screws of following sizes. The JBs Side plates shall be suitable for fixing metal and PVC raceways and knockouts to fit 20 25 32mm conduit entry. For (50300x38mm) duct.Dimensions:372x372x60mm. 10 mm Recess

100

3696

369600

... More
Man643 - SUPPLY and INSTALLATION OF LIGHT FIXTURES Supply, fixing, wiring and Installation commisioning LED light fitting with driver having efficiency 85percent and in compliance to IEC standards suitable for continuous operation with THD 10percent, power factor 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. The fittings shall be made from die Cast aluminum housing, Heat sink for heat dissipation, high purity reflector, lumen efficeancy of 70 lm Watt output. Fixture shall be CE compliance. Supplying of ......feet PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours and 70percent lumen maintenance with CRI 80. Power Input: 220240V at 50 60Hz and Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x 2 9 10w (Similar to Wipro make Trim Neo LED LL20111XXX65NE3).

47

578

27191.85

... More
Man644 - SUPPLY and INSTALLATION OF LIGHT FIXTURES Supply, fixing, wiring and Installation commisioning LED light fitting with driver having efficiency 85percent and in compliance to IEC standards suitable for continuous operation with THD 10percent, power factor 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. The fittings shall be made from die Cast aluminum housing, Heat sink for heat dissipation, high purity reflector, lumen efficeancy of 70 lm Watt output. Fixture shall be CE compliance. Supplying of ......feet PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours and 70percent lumen maintenance with CRI 80. Power Input: 220240V at 50 60Hz and Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4 20 22 w (Similar to Wipro make Trim Neo LED LL20221XXX65NE3).

478

724

346311

... More
Man645 - SUPPLY and INSTALLATION OF LIGHT FIXTURES Supply, fixing, wiring and Installation commisioning LED light fitting with driver having efficiency 85percent and in compliance to IEC standards suitable for continuous operation with THD 10percent, power factor 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. The fittings shall be made from die Cast aluminum housing, Heat sink for heat dissipation, high purity reflector, lumen efficeancy of 70 lm Watt output. Fixture shall be CE compliance. Supplying of ......feet PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours and 70percent lumen maintenance with CRI 80. Power Input: 220240V at 50 60Hz and Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. Fixing all types and all capacities of 1 x4 2 x2 LED Light fittings indoor on the wall ceiling rafters girders with necessary supporting frame, using 2310.0076inches twin twisted PVC insulated wires, required Nos of round blocks and clamps.

525

514

270112.5

... More
Man646 - Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure diecast extruded aluminium housing, with spring loaded fase ceiling clamps,Power LEDs with CCT 6500 degree K, CRI 70percent. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5percent of lamp wattage., short circuit and open circuit protection to be integrated in the circuit, , THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. a) LED Down light 1518W (Similar to Wipro make Elate CRCO10S038HP57GL1).

100

1754

175455

... More
Man647 - Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure diecast extruded aluminium housing, with spring loaded fase ceiling clamps,Power LEDs with CCT 6500 degree K, CRI 70percent. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5percent of lamp wattage., short circuit and open circuit protection to be integrated in the circuit, , THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. b) LED Down light 24 W (Similar to Wipro make Elate CRCO10S038HP57GL1).

105

1819

191063.25

... More
Man648 - Supplying of Recess Surface mounting non integrated type LED down light...... W luminaire comprising of pressure decast extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power COB with CCT 6500 degree K, CRI 70percent. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322 IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED s are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5percent of lamp Wage, short circuit and open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical Condition. 1) 56W (Similar to Wipro make Garnet D650640 D640640).

158

845

133549.5

... More
Man649 - Supplying of Recess Surface mounting non integrated type LED Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power COB with CCT 6500 degree K, CRI 70percent. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322 IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED s are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5percent of lamp Wage, short circuit and open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical Condition. 2) LED 10 12 watts (Similar to wipro Garnet DN D731040 Surface D641240).

683

1332

910063.35

... More
Man650 - Supplying of Recess Surface mounting non integrated type LED down light...... W luminaire comprising of pressure decast extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power COB with CCT 6500 degree K, CRI 70percent. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322 IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED s are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5percent of lamp Wage, short circuit and open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical Condition. 3) LED 15 18 watts (Similar to wipro Garnet DN D731540 Surface D641840).

252

1754

442146.6

... More
Man651 - Supplying of Recess Surface mounting non integrated type LED down light...... W luminaire comprising of pressure decast extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power COB with CCT 6500 degree K, CRI 70percent. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322 IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED s are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5percent of lamp Wage, short circuit and open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical Condition. 3) 24 W watts Similar to wipro Halo DN CRDL11R033HP57** Surface Vertica LD3030136B40SS

47

1819

85523.55

... More
Man652 - Supply of LED FLOOD LIGHT luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percent, CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage Overload, short circuit misswiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50 60Hz application. Compliance to IS 10322 IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m w, nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree Nichia Lumileds Osram make LED Source.: Recess Mounted 150W LED Flood light : Squash Table Tennis. Similar to Wipro LH 14 192XXX57G2

24

13114

314748

... More
Man653 - Supply of LED FLOOD LIGHT luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percent, CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage Overload, short circuit misswiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50 60Hz application. Compliance to IS 10322 IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m w, nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree Nichia Lumileds Osram make LED Source.: Recess Mounted 180W LED Flood light : (badminton Enterence Terrace). Similar to Wipro LF2019206057G2

44

16237

714436.8

... More
Man654 - Supply of LED FLOOD LIGHT luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percent, CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage Overload, short circuit misswiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50 60Hz application. Compliance to IS 10322 IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m w, nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree Nichia Lumileds Osram make LED Source.: Recess Mounted 240W LED Flood light : (Multi Purpose Hall). Similar to wipro LF2034206057G2

36

23171

834170.4

... More
Man655 - LED Post Top Lantern GARDEN.: Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr at Lumen Maintenance of 70percent, CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage Overload, short circuit misswiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50 60Hz application. Compliance to IS 10322 1 EC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency 1301m w, nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree Nichia Lumileds Osram make LED Source.: LED Post Top Lantern with 35 40 W (Similar to Wipro make LP07431XXX57CL)

29

10103

292989.9

... More
Man656 - Supply of LED Bollard light fitting of ...W with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percent, CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage Overload, short circuit misswiring protection. Universal Voltage driver to operate wide voltage range from 100V to 270V 50 60Hz application. Compliance to IS 10322 IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB, with 2 years Warranty against any manufacturing defect working under standard electrical condition.: 8W 1 Mtr Height (Similar to Wipro make Whistling Oyster LB12131XXX6508).

11

4755

52309.4

... More
Man657 - Supplying and fixing of LED Bulk head of 10W with IP65 protection and IK 08 impact resistance suitable for surface and wall mounting applications. (similar to Wipro Make Moon Squre Round)

32

884

28291.2

... More
Man658 - Supplying and fixing of retrofit type LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70percent. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 and LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5percent of lamp Wage., short circuit and open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.: 18W, 6500K ( Similar to Wipro Make GCF 30128).

2

447

894.6

... More
Man659 - Supplying and fixing of retrofit type LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70percent. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 and LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5percent of lamp Wage., short circuit and open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.: 3 W 6500K: (Similar to Wipro Make Garnet D110327).

2

130

260.4

... More
Man660 - Supply of round square recess surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector and has swivelling unit of aluminium die cast eye ball and LED Lamp position retained by circular wire spring, with Life of 25000 burning hours and 70percent lumen maintenance with CRI 80. Power Input: 220240V at50 60Hz and Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical conditiondriver, etc. with all necessary accessories as required complete (auditorium): LED square or round down light 56W. (Similar to Wipro Make Garnet Step Light)

32

599

19185.6

... More
Man661 - Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power COB with CCT 6500 degree K, CRI 70percent. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322 IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED s are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5percent of lamp Wage, short circuit and open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical. : 1012W: (Similar to Flos make Ares Leila 536016)

32

1332

42638.4

... More
Man662 - FIXING OF LIGHT FIXTURES Fixing all types and all capacities of 1 x4 2 x2 LED Light fittings indoor on the wall ceiling rafters girders with necessary supporting frame, using 2310.0076inches twin twisted PVC insulated wires, required Nos of round blocks and clamps. a) On wall ceiling Rafter Girders

1589

514

817540.5

... More
Man663 - CHEMICAL EARTHING : For body application Supplying and Fixing Chemical earthling for grounding. Conduits, IC cutouts and other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance and capable of achieving ohmic value less than one ohm : Using 10ft. Copper bonded rod with backfill compound

30

8918

267561

... More
Man664 - CHEMICAL GEL EARTHING : For NEUTRAL APPLICATION Supplying and Fixing Chemical earthling for grounding. Conduits, IC cutouts and other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance and capable of achieving ohmic value less than one ohm : Using 10ft. SS rod with backfill compound

11

6541

71956.5

... More
Man665 - EARTHING CONDUCTORS GI Copper strips for grounding connections, using necessary fixing materials as required: 50 x 6 mm GI strip

236

228

54020.4

... More
Man666 - EARTHING CONDUCTORS GI Copper strips for grounding connections, using necessary fixing materials as required: 40 x 6 mm GI strip

368

190

69938.4

... More
Man667 - EARTHING CONDUCTORS GI Copper strips for grounding connections, using necessary fixing materials as required: 25 x 6 mm GI strip

1680

134

225792

... More
Man668 - Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing as required.

5

19

99.75

... More
Man669 - Providing and fixing 25 x 6 mm Copper strip on surface or in recess for connections etc. as required.

5

1155

5775

... More
Man670 - Providing and fixing 25 x 3 mm Copper strip on surface or in recess for connections etc. as required.

168

598

100548

... More
Man671 - Providing and fixing 40 x 6 mm Copper strip on surface or in recess for connections etc. as required.

168

1725

289825.2

... More
Man672 - Providing and fixing 8 SWG dia Cu. wire on surface or in recess for loop earthing as required.

105

110

11576.25

... More
Man673 - Coil Earthing: Providing and Errection of spiral earthing using 8 SWG GI wire for street light pole etc. The GI wire shall be buried to a minimum depth of 1.5 m, with excavation, refilling of earth and connecting GI wire to pole using GI bolt and nut complete as per drawing no. CED ELE S 5 and complete as required.

50

250

12547.5

... More
Man674 - MISELANEOUS ITEMS Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. Angle iron 40 x 40 x 6 mm

250

320

80062.5

... More
Man675 - MISELANEOUS ITEMS Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. Angle iron 50 x 50 x 6 mm

125

414

51843.75

... More
Man676 - Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Hard Soil

20

354

7098

... More
Man677 - Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. Hard Rock Latterite Rock latterite Soil

150

1273

191047.5

... More
Man678 - Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr

113.9

60

6936.51

... More
Man679 - Spreading and forming with sand all round the cable to a depth of 75 mm and width of 500 mm. (Does not include cost of sand).

1

12148

12148.5

... More
Man680 - Supplying of Sand

40

1549

61992

... More
Man681 - Providing and laying Table Moulded Bricks as per the norms.

30

5500

165000

... More
Man682 - Fabricating, supplying and erection of …Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m sec for …….Mtrs pole in single section and single joint welded as per IS 9595 IS 10178AWS having dimensions bottom …..mm, top….mm with 3mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTMA123 and 153 etc., (excluding foundation) as per drawing appended.: 3meters Top 70mm and bottom 130mm dia

28

6615

185220

... More
Man683 - Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole wall drain crossing with necessary clamping arrangements for UG cable of 1.1 KV class. (a) 50 mm dia

10

650

6500

... More
Man684 - Supply, Installation and commissioning of 8mm dia Aluminum Solid Round Conductor for building terrace as a air terminal and down condcutor as per required LPL, to meet the requirements for IS IEC 62305. Tested for Electrical Resistivity test (0.0293 ) as per IEC 62561 1and 2, Mechanical Load Test (216 Mpa) as per IEC 62561 2 and Salt Mist Test at 628 hrs with No sign of corrosion as per IEC 62561 2 and IEC 60068.2.52. The rate shall include required conductor holders (including suitable for truss), Cross Connectors, Straight Connectors, Expansion Piece with connector, etc. with all accessories complete as required. Similar to CAPE SRC 8 -AL

665

189

125685

... More
Man685 - Supply of 3000mm Vertical Airterminal of dia 1610 mm with Complete Support of 3no wall clamp selected as per angle of protection chart to meet the requirement of IS IEC 62305 .Tested for Electrical ,Mechanical and Chemical as per IEC 62561. CAPE Type: VATW3

7

6404

44828

... More
Man686 - Supply of Lightning counter LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME DATE setting and log viewing. Replaceable battery, working life minimum five years, Complies with IEC EN 625616. CAPE Type: PRO LEC Basic

1

41017

41017

... More
Man687 - Supply of Stainless Steel Test Joint with enclosure to interconnect between 8 mm Al. round conductor to 10 mm copper bonded round conductor or 40x6 GI strip, Test Parameter:Salt Spray Test for test joint plate No sign of Corrosion Tested as per IEC 625611

20

1687

33740

... More
Man688 - TEST LINK Test links as per specification grouted to wall at 1200mm above ground level complete with all fixing accessories etc., as required complete

14

380

5320

... More
Man689 - RUBBER MAT Supply of PVC grade Electrical insulation mat suitable for voltage rating upto 3.3 kV , confirming to IS: 15652:2006 with latest amendment , class A with thickness of 2 mm + 10percent, ISI marked complete as required.

10

1768

17680

... More
Man690 - Supplying and installing of CO22 Kgs capacity Fire Extinguishers for multipurpose (Servers, Panels, Computers, etc.). a) 4.5 ltre Kg.

8

4810

38480

... More
Man691 - Supplying of Two Bucket stand along with Buckets.

1

630

630

... More
Man692 - Supplying of HAND GLOVES.

1

170

170

... More
Man693 - Supplying of First Aid Box.

1

215

215

... More
Man694 - Supplying of First Aid Shock treatment Chart with Lamination.

1

225

225

... More
Man695 - Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.

20

585

11700

... More
Man696 - Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

1

141

141

... More
Man697 - PARTC: DG SET AND ALLIED WORKS DIESEL GENERATOR SET : Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as perBS 5514 ISO 3046 ISO 8528 and IS 1002 ISO 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spinon lube oil filter, Spinon dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10percent for one hour in 12 hours of operation, Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation. Alternator: Alternator is suitable for operation at 1500 RPM, 415 V, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS IEC 600341. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have 1.0 percent Voltage regulation (max) in static conditions IP: 23 protections with insulation class FandH Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14 16 gauge CRCA sheet and is powder coated for weatherproof and long lasting finish. The control panel consists of the following parts: PS0500 Controller, Aluminium bus bars with suitable capacity within outgoing terminals, Indicating lA for Load On and Set Running , Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. As per schedule B.

1

1999537

1999537.05

... More
Man698 - Supply, Erection, testing and commissioning of AMF panel suitable for .....kVA DG set. The panel is of cubical type base floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....A 4 pole contactor for alternator with thermal O L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start stop logic, Mains generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature Lube oil pressure engine speed, Voltage ampere Frequency kVA, Runninghour count, No of starts, Fault indication, over under speed, Fails to start, Low oil pleasure, High engine temperature, Under over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto Manual and Flat Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules. 250 KVA

1

295100

295100.4

... More
Man699 - Exhaust System (JOB WORK) Supply, receive at site, store, unpack, assemble and connect exhaust pipe with Class B MS pipe with flanges, fire fly gaskets, hardware, mineral wool and aluminium sheet cladding etc., as per specification inclusive of all supports of wall, ceiling, etc., complete as required. Individual Exhaust pipe including flexibles from set with mineral wool and Alu. clading etc., as required complete for 250 KVA DG set (diameter of the pipe shall be specified by the vendor) as per local norms.

90

5500

495000

... More
Man700 - Supplying and fixing of 75 MM thick, mineral wool insulation (of 150 Kg. Per cubic metre density) over the exhaust pipes of following diameter including cladding with aluminium sheet of 26 SWG and covering from outside complete, as required.

100

575

57500

... More
Man701 - Supporting work for exhaust system Steel work as required to support the exhaust system. Related civil works shall be included. Painting with two coats of primer and two coats of approved enamel paint.

5000

138

690000

... More
Man702 - Lightning arrestor Vertical air termination.

1

3700

3700

... More
Man703 - Supply, erection and testing of LED type Aviation obstruction light of comprising of cast aluminium housing with polycarbonate enclosure (similar to Bajaj make BGAV 302 LED) and completely wired for use on 230 250 V grade 50 cycle AC supply. Wipro Bajaj.

1

9000

9000

... More
Man704 - Professional charges towards obtaining permission for installation as well as for running of Generator set from Chief Electrical Inspector, Chief of State Pollution Control Board and any other statutory body as may be required.

1

125000

125000

... More
Man705 - PARTD: TELEPHONE, NETWORKING and TV SYSTEM: TELEPHONE SYSTEM Supply and fixing of RJ11 telephone socket in a suitable size modular MS Box covered with modular plate and concealed in wall including supply of all fixing materials, and associated civil works with interconnections etc. complete as required. Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.

95

353

33615.75

... More
Man706 - TELEPHONE SYSTEM Supply and fixing of RJ11 telephone socket in a suitable size modular MS Box covered with modular plate and concealed in wall including supply of all fixing materials, and associated civil works with interconnections etc. complete as required. Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 pair unarmored cable.

4275

22

94263.75

... More
Man707 - TELEPHONE SYSTEM Supply and fixing of RJ11 telephone socket in a suitable size modular MS Box covered with modular plate and concealed in wall including supply of all fixing materials, and associated civil works with interconnections etc. complete as required. Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 20 pair unarmored cable.

175

157

27562.5

... More
Man708 - Supplying and fixing of MDF krone junction box with KRONE Module Telephone cable termination.: 20 pair.

5

402

2010.75

... More
Man709 - UPS SYSTEM Supplying, erecting, testing and commissioning of ONLINE UPS system suitable for operation on 230V, 50Hz, A C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. a) 10 kVA ON LINE UPS

2

108748

217497

... More
Man710 - Supplying, installation, testing and commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries.: 26 AH capacity

120

3791

454986

... More
Man711 - PARTE: SUPPLY OF LIFTS: LIFTS Supply, installation, commissioning and testing of 13 passengers capacity elevators without machine room, etc., complete. Type of Elevator: Passenger Elevators Capacity of the Elevator (13 passengers) Speed: 1.50m s Number of floors to be served: Basement, ground to Fourth floor and Terrace Number of landing entrances: 7 (Seven) Number of Landing: 7 (Seven) Travel distance: 27.00m Size of Lift well available: 2700 mm x 2000mm Min. Lift pit depth available: 1600mm Lift car inside: 2300mm x 1550mm Lift car door finish: Stainless Steel Hairline finish Lift car finish for walls: Stainless Steel Hairline finish Type of car door: Automatic center opening Stainless steel hairline finish Type of landing door: Automatic center opening Stainless steel hairline finish Lift car ceiling and lighting: SS Moonlight

1

2159416

2159416.35

... More
Man712 - PHE WORK: SANITARY FIXTURES and CP FITTINGS EUROPEAN WATER CLOSET : Supply, installation, testing and commissioning of approved make starWhite Coloured Wall mounting constellation model European water closet P trap outlet with 32 mm dia Concealed dual type Flush tank to enable flushing pipe work concealed behind wall supporting CI MS bracket with CP bolts and nuts, plastic seat cover of approved make and colour with rubber buffers, flap, CP hinges, CP bolts and nuts, all of approved make etc., complete. cost should include all accessories as required for installation. (Water closet Make : TOTO Hindware Parryware) (Flush tank Make : Geberit) (Hindware Cat. No for wc : 20069 (P22.5)

71

11785

836749.2

... More
Man713 - HEALTH FAUCET : Supply, Installing, testing and commissioning of 15mm CP health faucet of approved make with necessary CP flexible hose 750mm long nozzle, CP angle Valve, CP wall flange complete. (Make : Jaquar Hindware Parryware)

71

1950

138450

... More
Man714 - Providing and fixing Toilet paper holder made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete Class Economy Make :Jaquar Cera Parryware

71

880

62547.45

... More
Man715 - WASH BASIN :Providing and fixing wash basin (basin above below semi counter) with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 630x450 mm with a 15 mm CP Brass single hole basin mixer, with 32mm dia CP waste coupling, 32 mm dia. CP bottle trap with PVC connecting pipe pipe, Bottle trap,M.S. wall brackets with a pair of SS screws to support the basin 1no. 15mm CP single lever Basin Mixer with , 2 no. 15mm CP angle valve with 450mm long CP inlet connection pipe, CP wall flange all of approved make, complete. (Wash Bain Make :TOTO Hindware Parryware) (CP fitting -Make :Jaquar Cera Parryware) (Hindware Cat. No for WB : 10049)

23

10368

238481.25

... More
Man716 - WASH BASIN : Providing and fixing wash basin (basin above below semi counter) with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer, with 32mm dia CP waste coupling, 32 mm dia. CP bottle trap with PVC connecting pipe pipe, Bottle trap,M.S. wall brackets with a pair of SS screws to support the basin 1no. 15mm CP single lever Basin Mixer with , 2 no. 15mm CP angle valve with 450mm long CP inlet connection pipe, CP wall flange all of approved make, complete. (Wash Bain Make :TOTO Hindware Parryware) (CP fitting -Make :Jaquar Cera Parryware) (Hindware Cat. No for RWB: 10096)

40

9636

385476

... More
Man717 - URINALS : Supply, installing, testing and commissioning of white glazed large small flat back Urinals SENSOR TYPE with 40mm dia CP waste coupling with dome type grating , 40mm dia CP bottle trap with extension pipe, urinal spreader, SS bolts and nuts to fix the urinal with all hangers and brackets complete with wall flanges. (Wash Bain Make :TOTO Hindware Parryware) (CP fitting -Make :Jaquar Cera Parryware) (Hindware Cat. No : 60018)

53

7108

376750.5

... More
Man718 - Supply and fixing, testing and commissioning of solid state, no touch operting, fully hygienic hand drier of approved shade with blower, continuous repeat usage, time delay, summer and winter control, music while drying, volume ON OFF controls including providing necessary bracket, cable from drier to plug, plug top key and lock etc. complete as required. Make : Utec UT501

10

11300

113000

... More
Man719 - Supply and fixing, testing and commissioning of approved make 15mm CP shower unit comprising of CP 15mm dia exposed single lever Divertor with CP spout, overhead shower set comprising of CP shower arm, rose, hand shower with flex tube etc.,complete with CP wall flanges.

8

8534

68275.2

... More
Man720 - Supply and fixing, testing and commissioning of approved make 25 Liter GEYSER including necessary fittings etc,.

8

14425

115400

... More
Man721 - Providing and fixing Double Towel rail 600mm length made of Stainless steel with all concealed fitting arrangements and all necessary accessories complete Class PREMIUM

8

4057

32457.6

... More
Man722 - Supply and fixing, testing and commissioning of approved make CP Double coat hook including necessary fittings.

71

294

20874

... More
Man723 - Supply and fixing, testing and commissioning of approved make soap Tray including necessary fittings.

8

890

7120

... More
Man724 - Supplying, fixing, testing and commissioning of approved make CP bib tap including necessary fittings.(for JANITOR ROOM)

2

1115

2230

... More
Man725 - Providing and fixing Liquid soap dispenser made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete of approved shade with continuous repeat usage, including providing necessary bracket, complete as required including cutting and making good the wall. ClassvPremium Make : Kimberly Clark

14

4005

56080.5

... More
Man726 - S.S.SINK: Collecting, Installing, testing and commissioning stainless steel sink with single bowl with drain board from 1 mm thick stainless steel, 18G high grade indestructable chrome nickel steel with top quality polish, 1 no. 50 mm dia CP waste coupling, with 1 no. 40mm dia CP bottle trap with extension pipe bottle trap with extension pipe, 15mm dia CP sink cock with swivel spout wall floor mounted type and necessary wall flanges. etc., complete. (Make Niral Franke Jaquar Cera Parryware)

7

9263

64841.7

... More
Man727 - Providing and fixing in position SWR PVC Moulded (IS: 14735) Pinches, Sinches, floor trap of self cleaning design of following sizes for the embedded areas. Making proper connection with, cutting chase hole in floors slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors where required. Make: Finolex Supreme: 100 mm inlet and 100 mm outlet (Urinal traps only)

18

825

14850

... More
Man728 - Providing and fixing in position SWR PVC Moulded (IS: 14735) Pinches, Sinches, floor trap of self cleaning design of following sizes for the embedded areas. Making proper connection with, cutting chase hole in floors slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors where required. Make: Finolex Supreme: 100 mm inlet and 75 mm outlet (Floor Trap only)

85

256

21777

... More
Man729 - Supply and fixing of SS grating sutable for above mentioned floor trap (heavy quality Chilly make) and with necessary cement concrete. Make: Chilly Cat No: CCTSMHC140

103

825

84975

... More
Man730 - Supplying ,installation, testing and commissioning of approved make grab bar for handicap toilet including necessary fittings.

8

8566

68535.6

... More
Man731 - SOIL WASTE VENT AND RAIN WATER PIPES: Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For inclusive of all necessary specials like multi floor traps (50mm water seal), bends 45 or 90 degree, Y s, tees, offsets, junctions, couplers screw type caps with rubber rings for cleanout pipe ends, etc., Running in the ceiling. All suspenders, saddles, pipe packs are to be quoted separately under relevant items. All including Toilets, Pantry s and Basement ceilings (Make :Astral , Supreme and Prince): : PVC pipes 75mm dia., 6 kg sqcm and class 3

750

231

173250

... More
Man732 - SOIL WASTE VENT AND RAIN WATER PIPES: Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For inclusive of all necessary specials like multi floor traps (50mm water seal), bends 45 or 90 degree, Y s, tees, offsets, junctions, couplers screw type caps with rubber rings for cleanout pipe ends, etc., Running in the ceiling. All suspenders, saddles, pipe packs are to be quoted separately under relevant items. All including Toilets, Pantry s and Basement ceilings (Make :Astral , Supreme and Prince): PVC pipes 110mm dia., 6 kg sqcm and class 3

900

431

388395

... More
Man733 - SOIL WASTE VENT AND RAIN WATER PIPES: Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For inclusive of all necessary specials like multi floor traps (50mm water seal), bends 45 or 90 degree, Y s, tees, offsets, junctions, couplers screw type caps with rubber rings for cleanout pipe ends, etc., Running in the ceiling. All suspenders, saddles, pipe packs are to be quoted separately under relevant items. All including Toilets, Pantry s and Basement ceilings (Make :Astral , Supreme and Prince): PVC pipes 160mm dia., 6 kg sqcm and class 3

100

648

64890

... More
Man734 - SOIL WASTE VENT AND RAIN WATER PIPES: Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For inclusive of all necessary specials like multi floor traps (50mm water seal), bends 45 or 90 degree, Y s, tees, offsets, junctions, couplers screw type caps with rubber rings for cleanout pipe ends, etc., Running in the ceiling. All suspenders, saddles, pipe packs are to be quoted separately under relevant items. All including Toilets, Pantry s and Basement ceilings (Make :Astral , Supreme and Prince): PVC pipes 200mm dia., 6 kg sqcm and class 3

1

1170

1170.75

... More
Man735 - Supplying, fixing and testing PVC pressure pipes (6Kg sqcm) confirming to IS 4985 for waste connection from wash basin, kitchen sinks to floor trap, antisyphonage vent pipe with solvent cement joints, including all the fittings, suspended under floor slabs concealed in wall etc, the work shall include wall chase and making good the same in cement mortar. All suspenders, saddles, pipe packs are to be quoted separately under relevant items. (internal toilet) (Make :Astral , Supreme and Prince): 40mm dial (I.D.)

325

120

39000

... More
Man736 - Supplying, fixing and testing PVC pressure pipes (6Kg sqcm) confirming to IS 4985 for waste connection from wash basin, kitchen sinks to floor trap, antisyphonage vent pipe with solvent cement joints, including all the fittings, suspended under floor slabs concealed in wall etc, the work shall include wall chase and making good the same in cement mortar. All suspenders, saddles, pipe packs are to be quoted separately under relevant items. (internal toilet) (Make :Astral , Supreme and Prince): 50mm dia (I.D.)

180

106

19089

... More
Man737 - Supplying, fixing and testing PVC soil, waste, vent (SWR) confirming to IS13592 : 1990, Class A with rubber ring (confirming to IS 5382)with solvent joint inclusive of all necessary with all fittings like bends 45 or 90 degree, Y s, tees, offsets, door bends, junctions, screw type caps, vent cowl fixed in the pipe shafts on pipe racks (Vertical stacks for rain water) (Make :Astral , Supreme and Prince): 110mm dia (Type A)

182

480

87360

... More
Man738 - Supplying, fixing and testing PVC soil, waste, vent (SWR) confirming to IS13592 : 1990, Class A with rubber ring (confirming to IS 5382)with solvent joint inclusive of all necessary with all fittings like bends 45 or 90 degree, Y s, tees, offsets, door bends, junctions, screw type caps, vent cowl fixed in the pipe shafts on pipe racks (Vertical stacks for rain water) (Make :Astral , Supreme and Prince): 160mm dia (Type A)

315

950

299250

... More
Man739 - Supplying, fixing and testing PVC soil, waste, vent (SWR) confirming to IS13592 : 1990, Class A with rubber ring (confirming to IS 5382)with solvent joint inclusive of all necessary with all fittings like bends 45 or 90 degree, Y s, tees, offsets, door bends, junctions, screw type caps, vent cowl fixed in the pipe shafts on pipe racks (Vertical stacks for rain water) (Make :Astral , Supreme and Prince): 200mm dia (Type A)

385

1450

558250

... More
Man740 - Supplying, fixing and testing PVC soil, waste, vent (SWR) confirming to IS13592 : 1990, Class A with rubber ring (confirming to IS 5382)with solvent joint inclusive of all necessary with all fittings like bends 45 or 90 degree, Y s, tees, offsets, door bends, junctions, screw type caps, vent cowl fixed in the pipe shafts on pipe racks (Vertical stacks for rain water) (Make :Astral , Supreme and Prince): 250mm dia (Type A)

110

1655

182050

... More
Man741 - Supplying and fixing of PVC top grating of ACO Rainwater Roof Outlet Vertical Spigot with Dome Grate for below mentioned diameater rainwater outlets on Roof including all necessary grounting with sealants to make it absolutely water proof.: 110mm dia

12

1600

19200

... More
Man742 - Supplying and fixing of PVC top grating of ACO Rainwater Roof Outlet Vertical Spigot with Dome Grate for below mentioned diameater rainwater outlets on Roof including all necessary grounting with sealants to make it absolutely water proof.: 160mm dia

12

1850

22200

... More
Man743 - Supplying and fixing of PVC top grating of ACO Rainwater Roof Outlet Vertical Spigot with Dome Grate for below mentioned diameater rainwater outlets on Roof including all necessary grounting with sealants to make it absolutely water proof.: 200mm dia

15

2150

32250

... More
Man744 - INTERNAL WATER SUPPLY SYSTEM: Providing, fixing, jointing and testing in position the following CPVC pipes (up to 50mm SDR11 and above 50mm sch40 for sch40 pipes fittings shall be sch80) use, cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. fixing supported by M.S .angle Brackets with universal clamps,supports, etc. as per specification. And PVC pipe sleeve of larger diameter shall be provided wherever the pipes are crossing the walls chaseing floors slab and sealing the sleeves as per Consultant s requirement. Jointing, and making proper connections, cutting hole in wall floor slab and making good the same good with cement concrete 1:2:4, complete required as per specifications. ( For toilet Internal cold and Hot water Supply ) (Make :Astral, Supreme and Truflo): 20 mm dia

1320

227

300762

... More
Man745 - INTERNAL WATER SUPPLY SYSTEM: Providing, fixing, jointing and testing in position the following CPVC pipes (up to 50mm SDR11 and above 50mm sch40 for sch40 pipes fittings shall be sch80) use, cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. fixing supported by M.S .angle Brackets with universal clamps,supports, etc. as per specification. And PVC pipe sleeve of larger diameter shall be provided wherever the pipes are crossing the walls chaseing floors slab and sealing the sleeves as per Consultant s requirement. Jointing, and making proper connections, cutting hole in wall floor slab and making good the same good with cement concrete 1:2:4, complete required as per specifications. ( For toilet Internal cold and Hot water Supply ) (Make :Astral, Supreme and Truflo): 25 mm dia

175

310

54390

... More
Man746 - INTERNAL WATER SUPPLY SYSTEM: Providing, fixing, jointing and testing in position the following CPVC pipes (up to 50mm SDR11 and above 50mm sch40 for sch40 pipes fittings shall be sch80) use, cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. fixing supported by M.S .angle Brackets with universal clamps,supports, etc. as per specification. And PVC pipe sleeve of larger diameter shall be provided wherever the pipes are crossing the walls chaseing floors slab and sealing the sleeves as per Consultant s requirement. Jointing, and making proper connections, cutting hole in wall floor slab and making good the same good with cement concrete 1:2:4, complete required as per specifications. ( For toilet Internal cold and Hot water Supply ) (Make :Astral, Supreme and Truflo): 32 mm dia

135

390

52731

... More
Man747 - INTERNAL WATER SUPPLY SYSTEM: Providing, fixing, jointing and testing in position the following CPVC pipes (up to 50mm SDR11 and above 50mm sch40 for sch40 pipes fittings shall be sch80) use, cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. fixing supported by M.S .angle Brackets with universal clamps,supports, etc. as per specification. And PVC pipe sleeve of larger diameter shall be provided wherever the pipes are crossing the walls chaseing floors slab and sealing the sleeves as per Consultant s requirement. Jointing, and making proper connections, cutting hole in wall floor slab and making good the same good with cement concrete 1:2:4, complete required as per specifications. ( For toilet Internal cold and Hot water Supply ) (Make :Astral, Supreme and Truflo): 40 mm dia

532

500

266452.2

... More
Man748 - INTERNAL WATER SUPPLY SYSTEM: Providing, fixing, jointing and testing in position the following CPVC pipes (up to 50mm SDR11 and above 50mm sch40 for sch40 pipes fittings shall be sch80) use, cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. fixing supported by M.S .angle Brackets with universal clamps,supports, etc. as per specification. And PVC pipe sleeve of larger diameter shall be provided wherever the pipes are crossing the walls chaseing floors slab and sealing the sleeves as per Consultant s requirement. Jointing, and making proper connections, cutting hole in wall floor slab and making good the same good with cement concrete 1:2:4, complete required as per specifications. ( For toilet Internal cold and Hot water Supply ) (Make :Astral, Supreme and Truflo): 50 mm dia

18

757

13626.9

... More
Man749 - INTERNAL WATER SUPPLY SYSTEM: Providing, fixing, jointing and testing in position the following CPVC pipes (up to 50mm SDR11 and above 50mm sch40 for sch40 pipes fittings shall be sch80) use, cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. fixing supported by M.S .angle Brackets with universal clamps,supports, etc. as per specification. And PVC pipe sleeve of larger diameter shall be provided wherever the pipes are crossing the walls chaseing floors slab and sealing the sleeves as per Consultant s requirement. Jointing, and making proper connections, cutting hole in wall floor slab and making good the same good with cement concrete 1:2:4, complete required as per specifications. ( For toilet Internal cold and Hot water Supply ) (Make :Astral, Supreme and Truflo): 65 mm dia

80

1470

117600

... More
Man750 - INTERNAL WATER SUPPLY SYSTEM: Providing, fixing, jointing and testing in position the following CPVC pipes (up to 50mm SDR11 and above 50mm sch40 for sch40 pipes fittings shall be sch80) use, cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. fixing supported by M.S .angle Brackets with universal clamps,supports, etc. as per specification. And PVC pipe sleeve of larger diameter shall be provided wherever the pipes are crossing the walls chaseing floors slab and sealing the sleeves as per Consultant s requirement. Jointing, and making proper connections, cutting hole in wall floor slab and making good the same good with cement concrete 1:2:4, complete required as per specifications. ( For toilet Internal cold and Hot water Supply ) (Make :Astral, Supreme and Truflo): 80 mm dia

75

1882

141198.75

... More
Man751 - Providing and fixing in position brass ball valve high or low pressure with plastic float of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipment with all leads complete as per specifications.: 20 mm dia

59

329

19452.3

... More
Man752 - Providing and fixing in position brass ball valve high or low pressure with plastic float of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipment with all leads complete as per specifications.: 25 mm dia

5

348

1743

... More
Man753 - Providing and fixing in position brass ball valve high or low pressure with plastic float of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipment with all leads complete as per specifications.: 32 mm dia

11

795

8745

... More
Man754 - Providing and fixing in position brass ball valve high or low pressure with plastic float of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipment with all leads complete as per specifications.: 40 mm dia

5

850

4250

... More
Man755 - Providing and fixing in position brass ball valve high or low pressure with plastic float of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipment with all leads complete as per specifications.: 50 mm dia

3

985

2955

... More
Man756 - Supplying, installing, testing and commissioning of heavy quality approved make butterfly valves with standard lever confirming to IS 13039 with necessary G.I. flanges, G.I. nuts, bolts, and washers, rubber gaskets etc., complete. : 65 mm dia

2

1752

3504

... More
Man757 - Supplying, installing, testing and commissioning of heavy quality approved make butterfly valves with standard lever confirming to IS 13039 with necessary G.I. flanges, G.I. nuts, bolts, and washers, rubber gaskets etc., complete. : 80 mm dia

1

1850

1850

... More
Man758 - Supplying, fixing and testing inlet, outlet, vent (puddle flanges for OHT) (2inches ASTM upvc sch.80 pipe + 1 Tee + 2 Elbow + 2 mosquito jali) and overflow pipes, fittings with heavy duty CI frame and man hole cover including painting with 3 coats of bitumastic paint to overhead water tank complete with SS lader PVC rungs as required by client as shown in drawing etc., complete, accessories comprising of the following for Fire and Domestic water supply. (Approx. depth = 1,5 Mts. complete for efficient maintenance of the tanks Note : All Heavy duty GI puddle flanges should be hotdip galvanised.)

1

65000

65000

... More
Man759 - Supplying, fixing, testing and commissioning of water level controler for OHT including cable etc,. Compleat.

2

18000

36000

... More
Man760 - EXTERNAL WATER SUPPLY SYSTEM: Supplying, fixing and testing inlet, outlet, vent (puddle flange) (2inches ASTM upvc sch.80 pipe + 1 Tee + 2 Elbow + 2 mosquito jali) and overflow pipes, fittings with heavy duty circular CI frame and cover including painting with 3 coats of bitumastic paint complete with SS lader as required by client as shown in drawing etc., complete, accessories comprising of the following for Fire, Domestic and Flushing water supply.( Approx. depth = 4 5 Mts,complete all the Puddle flanges and details as given in the drawings,etc. complete for efficient maintenance of the tanks,Note : All Heavy duty GI puddle flanges should be hotdip galvanised.) (UNDERGROUND SUMP puddle flange detail)

1

95000

95000

... More
Man761 - KSRB 22 : Earthwork excavation by manual means for foundation of buildings, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications.KSRB 22.1: in ordinary soil. No. KBS 2.1(a) 2.3.5

25

254

6352.5

... More
Man762 - KSRB 22 : Earthwork excavation by manual means for foundation of buildings, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications.KSRB 22.2 : in hard soil. No. KBS 2.1(b) 2.3.5

25

271

6798.75

... More
Man763 - Providing, fixing, jointing and testing in position the following UPVC pipes (Schd40 pipes ) cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. fixing for Terrace Ring level supported by M.S .angle Brackets with universal clamps,supports, etc. as per specification. And PVC pipe sleeve of larger diameter shall be provided wherever the pipes are crossing the walls floors slab and sealing the sleeves as per Consultant s requirement. Jointing, and making proper connections, cutting hole in wall floor slab and making good the same good with cement concrete 1:2:4, complete required as per specifications. a) 80 mm dia (Make :Astral, Supreme and Prince)

50

535

26750

... More
Man764 - Providing, fixing, jointing and testing of water meter with stop cock, jam nut, sccket in GI pipe line including cutting and threading the pipe and making long screws including cost of all meteriala, labour, HOM of spesification.

1

1375

1375

... More
Man765 - Constructing brick masonry valve chamber 450x450mm and 450 mm depth, (clear inside dimension) for single pipeline, using table moulded nonmodular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) 600x600 internal dimensions, total weight of cover with frame to be not less than 38kg (weight of cover 23kg and weight of frame 15 kg) R.C.C. Top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS

1

4416

4416

... More
Man766 - EXTERNAL SEWERAGE SYSTEM: Earthwork excavation by manual means for foundation of buildings, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications.: in ordinary soil. No.

1

254

254.1

... More
Man767 - Earthwork excavation by manual means for foundation of buildings, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications: in hard soil.

1

271

271.95

... More
Man768 - Supplying, fixing and testing PVC soil, waste, vent(SWR) confirming to IS13592 : 1990, type B with solvent joint inclusive of all necessary specials like multi floor traps (50mm water seal), bends 45 or 90 degree, Y s, tees, offsets, junctions, couplers screw type caps with rubber rings for cleanout pipe ends, etc., Running in the ceiling. All suspenders, saddles, pipe packs are to be quoted separately under relevant items . (Main sewage header pipes to STP) (Make :Astral, Supreme and Truflo ): 160mm dia

1

600

600

... More
Man769 - Supplying, fixing and testing PVC soil, waste, vent(SWR) confirming to IS13592 : 1990, type B with solvent joint inclusive of all necessary specials like multi floor traps (50mm water seal), bends 45 or 90 degree, Y s, tees, offsets, junctions, couplers screw type caps with rubber rings for cleanout pipe ends, etc., Running in the ceiling. All suspenders, saddles, pipe packs are to be quoted separately under relevant items . (Main sewage header pipes to STP) (Make :Astral, Supreme and Truflo ): 110mm dia

1

490

490

... More
Man770 - Construction of 600mm X 600mm GULLY TRAP fixing with PVC inchesPinchesTrap. with 230mm best quality approved Table Moulded bricks in CM 1:4 over a bed of 100mm thick PCC 1:4:8, internal wall surfaces smooth plastered in CM 1:3 and external wall surfaces with CM 1:3 with sponge finish, benching and channelling in PCC 1:4:8. Supplying and fixing medium duty (10 MT load bearing capacity) FRP GRP square frame and cover of size suitable for a clear internal size of chamber of 600 x 600 mm The quoted rate shall also include necessary excavation and back filling. Clear internal size of the chamber 600 x 600 mm maximum depth not exceeding 900 mm.

1

8488

8488.48

... More
Man771 - KSRB 128.1 : Constructing brick masonry inspection chamber 600x600mm and 1000mm depth, (clear inside dimension) for single pipeline, using table moulded nonmodular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) 600x600mm internal dimensions, total weight of cover with frame to be not less than 38kg (weight of cover 23kg and weight of frame 15 kg) R.C.C. Top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications.Specification No. KBS

1

7075

7075

... More
Man772 - EXTERNAL STORM WATER SYSTEM: Earthwork excavation by manual means for foundation of buildings, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications: in ordinary soil. No.

70

254

17787

... More
Man773 - Earthwork excavation by manual means for foundation of buildings, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications.

38

271

10334.1

... More
Man774 - Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for:. The quoted rate shall include necessary fittings, pipe to be laid below ground level in trenches upto required depth, dewatering, jointing of pipes, water testing and setting encasing the pipes in cement concrete M15 as per specifications 150mm thk. all around, refilling, and making good the same complete as required. (Make :Astral, Supreme and Prince ): Pipes of SN4, 110mm dia.

2

302

604.8

... More
Man775 - Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for:. The quoted rate shall include necessary fittings, pipe to be laid below ground level in trenches upto required depth, dewatering, jointing of pipes, water testing and setting encasing the pipes in cement concrete M15 as per specifications 150mm thk. all around, refilling, and making good the same complete as required. (Make :Astral, Supreme and Prince ): Pipes of SN4, 160mm dia.

2

604

1209.6

... More
Man776 - Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for:. The quoted rate shall include necessary fittings, pipe to be laid below ground level in trenches upto required depth, dewatering, jointing of pipes, water testing and setting encasing the pipes in cement concrete M15 as per specifications 150mm thk. all around, refilling, and making good the same complete as required. (Make :Astral, Supreme and Prince ): Pipes of SN4, 200mm dia.

1

872

872.55

... More
Man777 - Constructing brick masonry catch basin for single pipeline, using table moulded nonmodular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) internal dimensions, total weight of cover with frame to be not less than 38kg (weight of cover 23kg and weight of frame 15 kg) R.C.C. Top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications.a) 600mm x 600mm (clear internal dimension) (For catch basin)

1

7075

7075

... More
Man778 - PUMPS AND ACCESSORIES: Providing and Supplying of Filter feed Centrifugal pumps or monoblock pump for domestic water from Treated water sump to OHT. The system shall comprises of 2 nos (1 working and 1 no. 100percent stand by pump) including with necessary unions, flanges, non return valves, other valves,. Make : DP pumps ITT GRUNDFOS 2.5 lps at 40 m Head.

4

38350

153400

... More
Man779 - Fixing, testing and commissioning of Filter feed Centrifugal pumps or monoblock pump for domestic water from Treated water sump to OHT. The system shall comprises of 2 nos (1 working and 1 no. 100percent stand by pump) including with necessary unions, flanges, non return valves, other valves,. Make : DP pumps ITT GRUNDFOS 2.5 lps at 40 m Head.

4

2350

9400

... More
Man780 - Providing and supplying of Filter feed Centrifugal pumps or monoblock pump for Flushing water from Flushing water sump(STP) to flushing OHT. The system shall comprises of 2 nos (1 working and 1 no. 100percent stand by pump) including with necessary unions, flanges, non return valves, other valves,. Make : DP pumps ITT GRUNDFOS 1.5 lps at 40 m Head.(1W +1S)

4

36500

146000

... More
Man781 - Fixing, testing and commissioning of Filter feed Centrifugal pumps or monoblock pump for Flushing water from Flushing water sump(STP) to flushing OHT. The system shall comprises of 2 nos (1 working and 1 no. 100percent stand by pump) including with necessary unions, flanges, non return valves, other valves,. Make : DP pumps ITT GRUNDFOS 1.5 lps at 40 m Head.(1W +1S)

4

2350

9400

... More
Man782 - Providing and supplying of dewatering lift pumps for PHE Fire Pump room (Submersible type) of adequate HP, capable of giving a required discharge at suitable head to work on 3Ph 50Hz, 400 440V with necessary unions, flanges, non return valves, other valves, with water level controller with cabling etc., complete. Make : DP pumps ITT GRUNDFOS 2.5 Lps at 15 m Head.(1W + 1S)

2

28320

56640

... More
Man783 - Fixing, testing and commissioning of dewatering lift pumps for PHE Fire Pump room (Submersible type) of adequate HP, capable of giving a required discharge at suitable head to work on 3Ph 50Hz, 400 440V with necessary unions, flanges, non return valves, other valves, with water level controller with cabling etc., complete. Make : DP pumps ITT GRUNDFOS 2.5 Lps at 15 m Head.(1W + 1S)

2

2400

4800

... More
Man784 - Providing and supplying of dewatering lift pumps for basement storm water collection sump(Submersible type) of adequate HP, capable of giving a required discharge at suitable head to work on 3Ph 50Hz, 400 440V with necessary unions, flanges, non return valves, other valves, with water level controller with cabling etc., complete. Make : DP pumps ITT GRUNDFOS 1.5 Lps at 10 m Head.(1W + 1S)

2

23320

46640

... More
Man785 - Fixing, testing and commissioning of dewatering lift pumps for basement storm water collection sump(Submersible type) of adequate HP, capable of giving a required discharge at suitable head to work on 3Ph 50Hz, 400 440V with necessary unions, flanges, non return valves, other valves, with water level controller with cabling etc., complete. Make : DP pumps ITT GRUNDFOS 1.5 Lps at 10 m Head.(1W + 1S)

2

3180

6360

... More
Man786 - Collecting, fixing, testing and commissioning of Filter feed Centrifugal pumps for domestic water from Raw water sump to treated water sump through the treatment Filter. The system shall comprises of 2 nos (1 working and 1 no. 100percent stand by pump) including with necessary unions, flanges, non return valves, other valves,. Make : DP pumps ITT GRUNDFOS 1.5 Lps at 30 m Head.(1W + 1S)

2

31592

63184

... More
Man787 - Collecting, fixing, testing and commissioning of Filter feed Centrifugal pumps for domestic water from Raw water sump to treated water sump through the treatment Filter. The system shall comprises of 2 nos (1 working and 1 no. 100percent stand by pump) including with necessary unions, flanges, non return valves, other valves,. Make : DP pumps ITT GRUNDFOS 1.5 Lps at 30 m Head.(1W + 1S)

2

2350

4700

... More
Man788 - Providing and supplying of Electrical Control panel starters for complete operation of Pumping system.

1

291500

291500

... More
Man789 - Fixing, installaition, testing and commissioning of Electrical Control panel starters for complete operation of Pumping system.

1

30000

30000

... More
Man790 - WATER TREATMENT PLANT: Providing and Supplying of approved make pressure sand filter of MS construction with necessary equipment complete with Frontal piping, pneumatic valves, suitable supports for mounting, pressure guage, orifice plate etc..,complete as per the detailed specification for the efficient working of system. The maximum working Pressure shall be 3.5Kg Sqcm.(Note : Pump quantity included in part VII Pump and accessories) Capacity : Max flow rate = 5.0cum hr

1

60060

60060

... More
Man791 - Installing, testing and commissioning approved make pressure sand filter of MS construction with necessary equipment complete with Frontal piping, pneumatic valves, suitable supports for mounting, pressure guage, orifice plate etc..,complete as per the detailed specification for the efficient working of system. The maximum working Pressure shall be 3.5Kg Sqcm.(Note : Pump quantity included in part VII Pump and accessories) Capacity : Max flow rate = 5.0cum hrInstallation

1

4500

4500

... More
Man792 - Fixing, Supplying approved make Raw water Softener with necessary accessories complete with Frontal piping,valves,suitable supports for mounting pressure guages,orifice plates.The filter shall be made of FRP with necessary protective coating.The cost of filter shall also include initial charge of underbed and multigrade filter media to suit the requirement etc.,complete as per the standards. Max. working pressure = 3.5kg sqcm Max flow rate = 5.0cum hr,

1

112500

112500

... More
Man793 - Installing, testing and commissioning approved make Raw water Softener with necessary accessories complete with Frontal piping,valves,suitable supports for mounting pressure guages,orifice plates.The filter shall be made of FRP with necessary protective coating.The cost of filter shall also include initial charge of underbed and multigrade filter media to suit the requirement etc.,complete as per the standards. Max. working pressure = 3.5kg sqcm Max flow rate = 5.0cum hr, Installation

1

5260

5260

... More
Man794 - Providing and Supplying of approved make activated carbon filter in MS vessel construction with internals, electrical control system complete with Frontal piping, valves, suitable supports for mounting, pressure gauge, orifice plate etc.., complete as per the detailed specification for the efficient working of system. The maximum working Pressure shall be 3.5 Kg Sqcm. Max flow rate = 5.0cum hr,

1

59310

59310

... More
Man795 - Fixing and (nstalling, testing and commissioning approved make activated carbon filter in MS vessel construction with internals, electrical control system complete with Frontal piping, valves, suitable supports for mounting, pressure gauge, orifice plate etc.., complete as per the detailed specification for the efficient working of system. The maximum working Pressure shall be 3.5 Kg Sqcm. Max flow rate = 5.0cum hr,

1

4500

4500

... More
Man796 - Providing and Supplying, installing, testing and commissioning of on line Automatic Electronic Metered Chlorine Dosing pump system including a 100L capacity storage tank etc., complete.

1

20700

20700

... More
Man797 - Installing, testing and commissioning of on line Automatic Electronic Metered Chlorine Dosing pump system including a 100L capacity storage tank etc., complete.

1

1800

1800

... More
Man798 - Supplying, installing, testing and commissioning inter unit piping with necessary flanges, bolts, nuts, neoprene gaskets, welding wherever necessary, with necessary control valves, non return valves etc and with one coat of primer and two coats of approved enamel paint etc., complete.

1

35200

35200

... More
Man799 - Fiixing, testing and commissioning inter unit piping with necessary flanges, bolts, nuts, neoprene gaskets, welding wherever necessary, with necessary control valves, non return valves etc and with one coat of primer and two coats of approved enamel paint etc., complete.

1

4800

4800

... More
Man800 - Supplying and providing of Level Switch for pump control

1

6200

6200

... More
Man801 - Fixing and installation of Level Switch for pump control

1

650

650

... More
Man802 - Supply, and Providing of water Flow meter to measure 0 5 cum hr, etc., complete

1

14500

14500

... More
Man803 - Fixing and installatopm of water Flow meter to measure 0 5 cum hr, etc., complete

1

1500

1500

... More
Man804 - Providing and supplying of Electrical Control panel starters for complete operation of WTP System

1

69120

69120

... More
Man805 - Fixing and Installation of Electrical Control panel starters for complete operation of WTP System

1

7680

7680

... More
Man806 - 25 KLD SEWAGE TREATMENT PLANT(SBR) (stp capacity higher side considering future expansion) Raw Sewage transfer pumps, Vertical centrifugal submersiable pumpsets with CI body and SS Shaft and with mechanical seal type 1 working + 1 standby with Capacity Head of 2.5 cum h at 10 mtr head. (Make: Grundfos Kirlosakar) (Purpose:For uniform pumping of raw sewage to SBR reactor from Equalisation tank)

2

39650

79300

... More
Man807 - Air blower (Driven by electric motor) Twin lobe air blowers type 1 working + 1 standby with Capacity Head of 70 cum hr. Max. operating pressure 0.50 kg sqcm. (Blower Make : Everest KPT KAY) (Motor Make : Kirlosakar) MOC :CI (Purpose:To provide aeration and carry out oxidation process and reduce BOD COD in SBR reactor, to provide mixing in equalization tank and sludge tank.)

2

113000

226000

... More
Man808 - Fine Bubble diffusers Imported fine bubble with silicon EPDM membrane in SBR tank, size 63 mm OD X 1000 mm long with SS clamps type (Make:Southern cogen ) (Purpose:Uniform air distribution into SBR tank )

8

3800

30400

... More
Man809 - Coarse Bubble diffusers Imported Coarse bubble with silicon EPDM membrane in Equalisation tank and Sludge holding tank Size 63 mm OD X 1000 mm long with SS clamps type (Make:Southern cogen ) (Purpose:Uniform air distribution into equivalisation tank and sludge tank)

4

3400

13600

... More
Man810 - Acoustic Enclosure :Supply, installation, testing and commissioning of acoustic enclosure for Air Blower fabricated out MS with 100mm thick Rockwool insulation so as to cut down the noise. The enclosure shall be provided with ventilating fan. The size of the enclosure shall be such that the enclosure can house two air blowers in one enclosure. Rate quoted shall be for 2 enclosures

2

150000

300000

... More
Man811 - Filter feed pumps Horizontal centrifugal non clog type pump set with CI impeller and mechnical Seal type, (1 working + 1 standby) with a Capacity Head of 2 cum hr at 35 mtr. Head ( Make : Kirlosakar) (Purpose : For pumping the clarified water for filteration through PSF and ACF with adequate pressure)

2

25000

50000

... More
Man812 - Bar screen : Type of screen M.S. Epoxy painted construction manually cleaned with flats placed at 10mm C C with M.S. hard rake with handle all epoxy painted.(Make : GEPS) (Purpose :Screening of Non degradable floating solids from incoming sewage and protection of pumps, and other equipment s etc. )

1

11000

11000

... More
Man813 - Pressure Sand filter : Flow 2 cum hr with working pressure of 3.5 kg sqcm, Dimensions 800 mm Dia X 1500 Height. MOC MS with Epoxy Coated and Silica Sand Media. (Make : GEPS) (Filtration and removal of trae suspended solids, carried over biomass etc. and improviding quality of treated water.)

1

90000

90000

... More
Man814 - Activated Carbon Filter : Flow 2 cum hr with working pressure of 3.5 kg sqcm, Dimensions 800 mm Dia X 1500 Height. MOC MS with Epoxy Coated and Activated carbon IV900 grade (Make : GEPS) ( Purpose :Filtration and removal of trae suspended solids, trace organic matter, removal of color and odour, and improving quality of treated water.)

1

92000

92000

... More
Man815 - Decantar System : Flow 2.5 cum hr with Flooting Tubler Type, Material PP, Dimensions 150mm. (Make : MAX)

1

48000

48000

... More
Man816 - Screw pump : Capacity of 1 cum hr at 50 mtr. Head (Make : ALFA) ( Purpose :To pump sludge for sludge dewatering unit for suldge treatment.)

1

18000

18000

... More
Man817 - Filter press : Size 470 mm x 470 mm 9 plates approx. Manual type, (Make : Royal precission ) ( Purpose : To dewater the sludge and to form dry sludge which can be easily disposeed off or can be used as manure.)

1

110000

110000

... More
Man818 - Hypo Chloride dosing system: Capacity 02 LPH (Make : Edose ) ( Purpose : For disinfection of treated water.)

1

9000

9000

... More
Man819 - Supplying, installation, testing and commissioning of Ultra filtration system with suitable UF Membrane, UF Feed Pump (1W+1S), UF Backwash Pump (1W+1S), PLC based auto panel, UF Skid made of SS 304, Basket Stainer, necessary dosing system as per membrane manufacturer specification

1

500000

500000

... More
Man820 - a) Air blower line except submerged air piping, type GI C Class, (Make : Jindal TATA )

1

34000

34000

... More
Man821 - b) All other pipe line for pumps UPVC type, (Makes of Astral Finolex Prince equivalent)

1

30000

30000

... More
Man822 - c) Float level switch (Make : Laptron Minilec. equivalent )

1

8000

8000

... More
Man823 - d) Sub merged air grid pipe and fittings CPVC type, (Makes Astral Prince Finolex equivalent )

1

14000

14000

... More
Man824 - e) Pressure guage ( Make : H Guru Warre equivalent )

1

12000

12000

... More
Man825 - f) Rotameter (Make : Aster Kranthi Pratham equivalent)

1

18000

18000

... More
Man826 - g) Valves ( Make : Mark sant equivalent )

1

18000

18000

... More
Man827 - h) Pipe supports : Galvanised M.S. section of required size

1

17000

17000

... More
Man828 - i) Anchor fastneners : Standard make of approved quality

1

10000

10000

... More
Man829 - j) Welding rods: Standard make of approved quality

1

4000

4000

... More
Man830 - Consumanbles : a) Nuts, Bolts, washers type M.S. hard dip GI Nut bolts

1

16000

16000

... More
Man831 - Consumanbles : b) Electrical Cables (Make:Poly cab Finolex Gloster)

1

20000

20000

... More
Man832 - Consumanbles : c) Cable tray Z angle type M.S. hard dip GI

1

16000

16000

... More
Man833 - Providing, supplying, commissioning and fixing of Electrical control panel :as per the detailed drawing and specification and the direction of engineer in charge of work.

1

177000

177000

... More
Man834 - Erection and commissioning of the Sewage Treatment Plant including Transportation Charges as per the drawing, specification and instruction of engineer in charge of work

1

180000

180000

... More
Man835 - FIRE FIGHTING WORKS: FIRE PUMP ROOM EQUIPMENT: Supply, installation, testing and Commissioning of approved make centrifugal pump end suction type couple to electrical motor of suitable HP, fitted on a common base frame and rated for for fire duty.The quoted price shall also include 2 nos. Pressure gauge fitted on suction and delivery side of the pump. The pump shall run on 400 440V,3ph.35Hz Electrical supply. Duty of pump 2280 Lpm at 70M Head.

1

230375

230375

... More
Man836 - Supply, installation, testing and Commissioning of Diesel Engine driven fire pump suitable for automatic operation comprising of the following and conforming to BS 649 IS 10002 all amended upto date. Supply, installation, testing and Commissioning of fire hydrant multi stage pump capable of delivering 2280 lpm at 70.0 m head coupled to water cooled diesel engine of adequiate HP. It shall be fitted with a radiator on a common base from with complete ancilalary units such as colling system,non return valve,y stainer,fuel tank of adequate capacity,pressure gauge,pressure switch.

1

395850

395850

... More
Man837 - Supplying, Installing, testing and commisioning electrically driven jockey pump of capacity 180.0 Lpm at 70.0m head with all the necessary accessories viz. Pressure guages etc. operating on 3Ph 50Hz, 400 440 V AC supply incldung foudnation, bolts etc. complete Control panel shall be per specification stated in Item No.87. including cost of materials, labour, HOM complete as per specifications. (Cost of controle pannel is not included)

1

61736

61736

... More
Man838 - Common Pump Control panel (Complete suit as per above mentioned pump spesifications): Fabricating and Supply, installing, testing and commissioning of compartmentalised common control panel for Electrical motor driven pumps and Jockey driven pumps. INCOMING 1 no. 250A TPN MCCB (25 KA). 1 Set of 250 Amps. TPN Al. Bus bars with colour coded heat shrinkable PVC sleeves. 1 Set of RYB indicating lamps with individual HRC control fuses. 1 No. 144 Sq.mm 0250 Amps. Ammeter with selector selector switch and suitable rated current transformers. 1 No. 0500 144 Sq.mm Voltmeter with selector switch. OUTGOING Feeder for 55 HP main pumps 1 Nos. 1 No.160 A TPN SFU with back up fuses Star Delta starter with over load relay, single phase preventor and indicating lamps with ON OFF push buttons. Feeder for 6 HP Jockey pump 1 No. 1 No. 32A TPN SFU with back up fuses star delta starter with over load relay, single phase preventor and indicating lamps with ON OFF push buttons. 1 No. Automanual selector switch

1

295000

295000

... More
Man839 - 1100 V GRADE POWER CONTROL CABLES : Supplying, laying, testing and commissioning of PVC XLPE insulated PVC sheathed, steel armoured, aluminium copper conductor, 100v grade power cables.The cables shall be laid in tray Hume pipe in trenches on walls floor etc. as required. : 3.5C x 50 sq.mm Aluminium. XLPE

50

600

30000

... More
Man840 - 1100 V GRADE POWER CONTROL CABLES : Supplying, laying, testing and commissioning of PVC XLPE insulated PVC sheathed, steel armoured, aluminium copper conductor, 100v grade power cables.The cables shall be laid in tray Hume pipe in trenches on walls floor etc. as required. : 4C x 25 sq.mm Aluminium. XLPE

40

300

12000

... More
Man841 - 1100 V GRADE POWER CONTROL CABLES : Supplying, laying, testing and commissioning of PVC XLPE insulated PVC sheathed, steel armoured, aluminium copper conductor, 100v grade power cables.The cables shall be laid in tray Hume pipe in trenches on walls floor etc. as required. : 2C x 2.5 Sqmm. Aluminium PVC

50

210

10500

... More
Man842 - CABLE TRAY (PERFORATED TYPE) Supplying and installing following size of perforated cable trays made out of 2mm thick Pregalvanised sheet steel and 16SWG unperforated type covers perforation not more than 17.5percent, in convenient sections, joined with connectors, suspended from the ceiling with Galvanised M10 Hitech rod suspenders including bolts, Anchor fasteners and nuts, etc with all accessories like bends, reducers, Tee s, cross members, etc. complete as required. 300 mm width X 50 mm depth X 1.6 mm thickness

25

616

15408.75

... More
Man843 - G.I. Earthing strips of, strip shall be run on floor ceiling walls, from the equipment to the nearest Earth pit with neccessory accessories as required. (Earth pit shall be executed by other agencies).: 25mm x 6mm thick

25

134

3350

... More
Man844 - Supplying, installing, testing and commissioning of M.S. Pipes confirming to IS 3589,6.35 mm thick for Dia 150 mm and above and below 150 mm the pipe shall cfn IS 1239 part1 (heavy duty), with specials such as Tees, elbows, flanges. Including cutting, Welding, fixing in on walls, ceiling by using suitable supports etc, as per drawings.: 200mm nominal dia

10

2100

21000

... More
Man845 - Supplying, installing, testing and commissioning of M.S. Pipes confirming to IS 3589,6.35 mm thick for Dia 150 mm and above and below 150 mm the pipe shall cfn IS 1239 part1 (heavy duty), with specials such as Tees, elbows, flanges. Including cutting, Welding, fixing in on walls, ceiling by using suitable supports etc, as per drawings.: 150 mm Nominal dia

20

2000

40000

... More
Man846 - Supplying, installing, testing and commissioning of M.S. Pipes confirming to IS 3589,6.35 mm thick for Dia 150 mm and above and below 150 mm the pipe shall cfn IS 1239 part1 (heavy duty), with specials such as Tees, elbows, flanges. Including cutting, Welding, fixing in on walls, ceiling by using suitable supports etc, as per drawings.: 100mm nominal dia

5

1188

5940

... More
Man847 - Supplying, installing, testing and commissioning of M.S. Pipes confirming to IS 3589,6.35 mm thick for Dia 150 mm and above and below 150 mm the pipe shall cfn IS 1239 part1 (heavy duty), with specials such as Tees, elbows, flanges. Including cutting, Welding, fixing in on walls, ceiling by using suitable supports etc, as per drawings.: 80 mm nominal dia

5

1024

5120

... More
Man848 - Supplying, Installing, testing and commissioning CI butterfly valves(PN 1.6) slim seal standared lever operated type confirming to BS:5155 with required flanges, nuts, bolts etc. complete.: 200mm nominal dia

1

12680

12680

... More
Man849 - Supplying, Installing, testing and commissioning CI butterfly valves(PN 1.6) slim seal standared lever operated type confirming to BS:5155 with required flanges, nuts, bolts etc. complete.: 150mm nominal dia

4

9500

38000

... More
Man850 - Supplying, Installing, testing and commissioning CI butterfly valves(PN 1.6) slim seal standared lever operated type confirming to BS:5155 with required flanges, nuts, bolts etc. complete.: 100mm nominal dia

2

7000

14000

... More
Man851 - Supplying, installing, testing and commissioning approved make Cast Iron body brass pot and Y strainer with necessary flanges, nuts and bolts etc., complete on to the suction line.: 200mm nominal dia Pot strainer

1

30200

30200

... More
Man852 - Supplying, installing, testing and commissioning of C.I. Nonreturn valves as per IS:5312( PN 10) swing check type with required flanges, nuts, bolts and gaskets etc. complete.: 200 mm nominal dia

1

12600

12600

... More
Man853 - Supplying, installing, testing and commissioning of C.I. Nonreturn valves as per IS:5312( PN 10) swing check type with required flanges, nuts, bolts and gaskets etc. complete.: 150 mm Nominal dia

2

9005

18010

... More
Man854 - Supplying, installing, testing and commissioning of C.I. Nonreturn valves as per IS:5312( PN 10) swing check type with required flanges, nuts, bolts and gaskets etc. complete.: 100 mm nominal dia

1

6900

6900

... More
Man855 - EXTERNAL HYDRANT SYSTEM: Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m,40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: 150mm nominal dia

16

1755

28080

... More
Man856 - Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m,40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: 80mm nominal dia

15

1056

15840

... More
Man857 - Supplying and wrapping the anticorrosive material for buried pipes with coating of Primer and wrapping with 4 mm thick polymer corrosion resistnt tape as per IS : 10221 with 15 mm overlap as per specifications. : 150mm nominal dia

16

105

1680

... More
Man858 - Supplying and wrapping the anticorrosive material for buried pipes with coating of Primer and wrapping with 4 mm thick polymer corrosion resistnt tape as per IS : 10221 with 15 mm overlap as per specifications.: 80mm nominal dia

15

80

1200

... More
Man859 - Supplying, installing and commissioning of fire brigade inlet inlet connection of 2 way with 2 nos. 63 mm dia. built in Gun metal Non return valves instantaneous coupling type arranged on 150 mm dia. Pipe manifold and connected to wet riser main. Qouted rate shall be included with C.I. Butterfly valve, C.I. check valve and M.S. cabinet of suitable size with mounting supports etc. complete.

1

9850

9850

... More
Man860 - Supplying, installing and commissioning of fire brigade inlet inlet connection of 4 way with 4 nos. 63 mm dia. built in Gun metal Non return valves instantaneous coupling type arranged on 150 mm dia. Pipe manifold and connected to wet riser main. Qouted rate shall be included with C.I. Butterfly valve, C.I. check valve and M.S. cabinet of suitable size with mounting supports etc. complete.

1

12500

12500

... More
Man861 - Supplying, installing, testing and commissioning of yard hydrant comprising of a) Supplying Installing, testing and commissioning of 63mm mm dia single headed Gun mental Hydrant Valve with flanged inlet, stop valve, spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21 Kgf cm2 pressure having a flow rate of 900 LPM at 7 Kgf cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete. Make : WINCO NEW Age including cost of materials, labour, HOM, Complete as per specifications. (Make : WINCO NEW Age)

5

5244

26220

... More
Man862 - Supplying, installing, testing and commissioning of yard hydrant comprising of b) Supplying Installing, testing and commissioning of Reinforced Rubber Lined RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female Instantainious Gun metal coupling as per IS 903 WINCO NEW AGE complete including cost of materials, labour, HOM complete as per specifications Make : WINCO NEW Age

10

5242

52420

... More
Man863 - Supplying, installing, testing and commissioning of yard hydrant comprising of c) Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 Make: WINCO NEW AGE complete including cost of materials, labour, HOM complete as per specifications. Make : WINCO NEW Age

5

2232

11160

... More
Man864 - Supplying Installing, testing and commissioning of Hose cabinet made out of 18 gauge M.S.sheet with double glass door with locing arrangement and painted with two coats of Fire red Enamel paint at outer ise of the Box and two coats of white enamel paint at inner side of the box is to accomodated 2 Nos. of Fire hose box size 20”x24”x10” complete including cost of materials, labour, HOM complete as per specifications.

5

3199

15995

... More
Man865 - CIVIL WORKS: Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings and bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools and other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m

95

254

24139.5

... More
Man866 - Providing and laying Reinforced Cement Concrete pipe light duty NP2 for culverts, roadway utilitiesand crossingsas per IS 458:2003 in Single row including pointing ends and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing completeas per specifications 300mm Dia

20

895

17913

... More
Man867 - INTERNAL HYDRANT SYSTEM: Supplying, erecting and commissioning of internal Hydrants comprising of the following in the Fire duct: a) Supplying Installing, testing and commissioning of 63mm mm dia single headed Gun mental Hydrant Valve with flanged inlet, stop valve, spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21 Kgf cm2 pressure having a flow rate of 900 LPM at 7 Kgf cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete. Make : WINCO NEW Age including cost of materials, labour, HOM complete as per specifications. (Make : WINCO NEW Age)

10

5244

52440

... More
Man868 - Supplying, erecting and commissioning of internal Hydrants comprising of the following in the Fire duct: b) Supplying Installing, testing and commissioning of Reinforced Rubber Lined RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female Instantainious Gun metal coupling as per IS 903 WINCO NEW AGE complete including cost of materials, labour, HOM complete as per specifications Make : WINCO NEW Age

20

5242

104840

... More
Man869 - Supplying, erecting and commissioning of internal Hydrants comprising of the following in the Fire duct: c) Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 Make: WINCO NEW AGE complete including cost of materials, labour, HOM complete as per specifications. Make : WINCO NEW Age

10

2232

22320

... More
Man870 - Supplying, erecting and commissioning of internal Hydrants comprising of the following in the Fire duct: d) Supplying Installing, testing and commissioning of Hose reel cabin M.S.Pressed reel of 600mm dia swinging type motion which allows a 180 degree swing and conforms to IS:884 85. including cost of materials, labour, HOM complete as per specifications.

10

3869

38690

... More
Man871 - Supplying, erecting and commissioning of internal Hydrants comprising of the following in the Fire duct: e) Supplying Installing, testing and commissioning of 19mm dia 36.50m length hose with rubber lining smooth bore, reinforced of natural synthetic fibres, a rubber cover finish shall be smooth, fluted or fabric marked with minimum thickness of 1.50mm and to with stand a working pressure of 10Kgf sqcm confirms and tested as per IS 444 including cost of materials, labour, HOM complete as per specifications.

16

3869

61904

... More
Man872 - Supplying, erecting and commissioning of internal Hydrants comprising of the following in the Fire duct: f) Supplying, installing, testing and commissioning of Fire duct Shutter fabricated out of M.S. sheet of 16 swg., door shall be 900mm x 1200 mm min. and fixed with 4 mm thick Glass, suitable Rubber beeding and Locking arrangement. Quoted rate shall be includes all fasteners etc, and complete shutter shall be powder coated of approved colour both inside and out side.

10

6200

62000

... More
Man873 - Supplying and fixing approved make 25mm dia. With automatic air release valve with unions, ball valve etc. complete.: 25mm dia.

2

1562

3124

... More
Man874 - Supplying, Installing, testing and commissioning CI butterfly valves(PN 16) slim seal standared lever operated type confirming to BS:5155 with required flanges, nuts, bolts etc. complete.: 100mm nominal dia

2

7000

14000

... More
Man875 - Supplying, installing, testing and commissioning approved make Cast Iron body brass pot and Y strainer with necessary flanges, nuts and bolts etc., complete on to the suction line.: 100mm nominal dia Y strainer

1

26000

26000

... More
Man876 - Supplying, installing, testing and commissioning of C.I. Nonreturn valves as per IS:5312(PN 16) swing check type with required flanges, nuts, bolts and gaskets etc. complete.: 100 mm nominal dia

1

9005

9005

... More
Man877 - Supplying, installing, testing and commissioning of GI Pipes conforming to IS 1239Part1 Heavy grade with 2 cote primer and painting, suitable type of supports(Shall be fabricated by MS Channel Angle Flat for above 50 mm dia), anchor fasteners, bolts nuts, inchesUinches clamps, bolt, M.S.angles malleable specials such as Reducers, Tees, elbows, flanges. Including cutting, Welding, fixing in on walls, ceiling by using suitable supports etc, as per drawings. The quoted rate shall also include for chasing chipping walls, making bore holes in walls floor and making them good with filler material and finished in cement mortar including two coats of metal primer and two coates of red enamel paint etc. complete.: a) 150mm nominal dia

195

1755

342225

... More
Man878 - Supplying, installing, testing and commissioning of GI Pipes conforming to IS 1239Part1 Heavy grade with 2 cote primer and painting, suitable type of supports(Shall be fabricated by MS Channel Angle Flat for above 50 mm dia), anchor fasteners, bolts nuts, inchesUinches clamps, bolt, M.S.angles malleable specials such as Reducers, Tees, elbows, flanges. Including cutting, Welding, fixing in on walls, ceiling by using suitable supports etc, as per drawings. The quoted rate shall also include for chasing chipping walls, making bore holes in walls floor and making them good with filler material and finished in cement mortar including two coats of metal primer and two coates of red enamel paint etc. complete.: b) 100mm nominal dia

11

1575

17325

... More
Man879 - Supplying, installing, testing and commissioning of GI Pipes conforming to IS 1239Part1 Heavy grade with 2 cote primer and painting, suitable type of supports(Shall be fabricated by MS Channel Angle Flat for above 50 mm dia), anchor fasteners, bolts nuts, inchesUinches clamps, bolt, M.S.angles malleable specials such as Reducers, Tees, elbows, flanges. Including cutting, Welding, fixing in on walls, ceiling by using suitable supports etc, as per drawings. The quoted rate shall also include for chasing chipping walls, making bore holes in walls floor and making them good with filler material and finished in cement mortar including two coats of metal primer and two coates of red enamel paint etc. complete.: c) 80mm nominal dia

70

1056

73920

... More
Man880 - SPRINKLER SYSTEM: Supplying Installing, testing and commissioning of approved make 15mm dia sprinkler bulb pendent wall mounted type designed to operate 68 degrees centegrad Make Tyco HD FIRE complete (Colour code of bulb liquid inside Glass bulb type Pendents As per IS 9972: 57 degree C Orange, 68 degree C Red, 79 degree C Yellow, 93 degree C Green, 141 degree C Blue, 182 degree C Mauve, 227 260 degree C Black) including cost of materials, labour, HOM complete as per specifications.: a) (Pendant Type)

556

530

294680

... More
Man881 - Supplying Installing, testing and commissioning of approved make 15mm dia sprinkler bulb pendent wall mounted type designed to operate 68 degrees centegrad Make Tyco HD FIRE complete (Colour code of bulb liquid inside Glass bulb type Pendents As per IS 9972: 57 degree C Orange, 68 degree C Red, 79 degree C Yellow, 93 degree C Green, 141 degree C Blue, 182 degree C Mauve, 227 260 degree C Black) including cost of materials, labour, HOM complete as per specifications.: b) (Upright Type)

650

530

344500

... More
Man882 - Supplying Installing, testing and commissioning of approved make 15mm dia sprinkler bulb pendent wall mounted type designed to operate 68 degrees centegrad Make Tyco HD FIRE complete (Colour code of bulb liquid inside Glass bulb type Pendents As per IS 9972: 57 degree C Orange, 68 degree C Red, 79 degree C Yellow, 93 degree C Green, 141 degree C Blue, 182 degree C Mauve, 227 260 degree C Black) including cost of materials, labour, HOM complete as per specifications.: c) (Side through)

52

530

27560

... More
Man883 - Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m, 40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: a) 150mm nominal dia

75

1755

131625

... More
Man884 - Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m, 40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: b) 100mm nominal dia

80

1575

126000

... More
Man885 - Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m, 40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: c) 80mm nominal dia

150

1056

158400

... More
Man886 - Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m, 40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: d) 65mm nominal dia

175

942

164850

... More
Man887 - Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m, 40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: e) 50mm nominal dia

360

827

297720

... More
Man888 - Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m, 40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: f) 40mm nominal dia

365

731

266815

... More
Man889 - Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m, 40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: g) 32mm nominal dia

85

683

58055

... More
Man890 - Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m, 40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: h) 25mm nominal dia

800

635

508000

... More
Man891 - Supplying, installing, testing and commissioning of hydraulically operated 150mm Sprinkler control valve, with water motor gong bell and trims as required, pressure gauges, drain valves, ball valves, check valves, strainers etc. complete.

1

19800

19800

... More
Man892 - Sprinkler Annunciation panel of 20 window capacity, for indicating the status of Flow switch mounted on the Sprinkler distribution main. Panel shall be solid state type with LED indicating lamps, push buttons like accept, reset, ON OFF etc. as reuqired with battery back up.

1

52000

52000

... More
Man893 - Supplying, installing, testing and commissioning flow switch on sprinkler distribution header on each floor and shall be connected to Annunciation panel through cable. Cable shall be measured seperately.: a) 150mm nominal dia

8

5000

40000

... More
Man894 - Supplying, installing, testing and commissioning flow switch on sprinkler distribution header on each floor and shall be connected to Annunciation panel through cable. Cable shall be measured seperately.: b) 100mm nominal dia

2

4100

8200

... More
Man895 - Supplying, installation, testing and commissioning of 2 runs of 1.5 sq.mm cross section armored cable.

350

110

38500

... More
Man896 - Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour, HOM complete as per specifications. Complete

3

1562

4686

... More
Man897 - Supplying, Installing, testing and commissioning CI butterfly valves (PN 1.6) slim seal standared lever operated type confirming to BS:5155 with required flanges, nuts, bolts etc. complete: . a) 150 mm nominal dia

6

9500

57000

... More
Man898 - Supplying, Installing, testing and commissioning CI butterfly valves (PN 1.6) slim seal standared lever operated type confirming to BS:5155 with required flanges, nuts, bolts etc. complete: .b) 100 mm nominal dia

2

7000

14000

... More
Man899 - SIGNAGES: Providing and fixing Fire Exit Sign Board (Size:15inchesx6inches)

12

1150

13800

... More
Man900 - Providing and fixing of Floor Name Board (Size:15inchesx6inches)

12

1150

13800

... More
Man901 - Providing and fixing of Use Staircase incase Fire (Size:18inchesx8inches)

12

1450

17400

... More
Man902 - FIRE EXTINGUISHERS: Supplying, installing and commissioning Portable Fire extinguishers of following type and capacity. Providing CO2 Aluminium 4.5kg Providing 4.5Kg CO2 Gas Type aluminium body Squeeze grip Fire Extinugisher, Trolley Mounted, Easy Weight Management, Used Unused Mechanism, Squeeze Grip, Gross Weight 11.16Kg. empty Weight 6.66Kg. Can Height 860MM Diameter 140MM, Discharge Time less than10 Secs, Controllable discharge mechanism, Applicable on Class BandC Fire, B Rating 13B, Can Constuction : Cold Impact Extrusion, Valve Construction : Forging and Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Aluminium metal ISO and PESO Approved, 3 Year Warranty. including cost of materials, labour, HOM complete as per specifications. complete

10

11785

117850

... More
Man903 - Providing CO2 Aluminium 2.0kg Providing 2Kg CO2 Gas aluminium body Squeeze grip Fire Extinugisher, Used Unused Mechanism, Squeeze Grip, Gross Weight 5.16 Kg. empty Weight 3.16Kg. Can Height 615MM Diameter 111MM, Discharge Time less than 8 Secs, Controllable discharge mechanism, Applicable on Class BandC Fire, B Rating 13B, Can Constuction : Cold Impact Extrusion, Valve Construction : Forging and Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Aluminium metal ISO and PESO Approved, 3 Year Warranty. including cost of materials, labour, HOM complete as per specifications. complete

8

8102

64816

... More
Man904 - Providing green Mist 9ltr Providing 9 Ltr Fire Extinugisher Aqueous FilmForming Foam Type, Stored Pressure Type, Pressure Gauge, Gross Weight 15.10kg. empty weight 6.10kg Can Height 615MM, Diameter 175 MM, Discharge Time less than 60 Secs, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 6 Meters, applicable on Class A,B,C A Rating 13A, B Rating 55B, Can Construction Deep drawn and CO, Mig welded, Valve Construction: Forging and Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy Polyster Powder coating, Sheet metal thickness: 2.0MM, ISI and EN Approved, Helium Leak Detection Tested, 1 Years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, HOM complete as per specifications. complete

8

6055

48440

... More
Man905 - Providing ABC Powder based MAP 50, 6.0KG Providing 6kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 9.5 Kg, empty weight 3.5 Kg, Can Height 435MM, Diameter 160MM, Discharge Time less than 9 Secs, Controllable discharge mechanism(Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,B,C and electrically started Fire, A Rating 3A, B Rating 21B, Can construction : Deep drawn and Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster power coating, Sheet metal thickness: 1.60MM, Helium Leak Detection Tested, ISI and EN Approved, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, HOM complete as per specifications. complete

8

4849

38792

... More
Man906 - Providing ABC Powder based MAP 50, 2.0KG Providing 2kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 3.6 Kg, empty weight 1.6 Kg, Can Height 344MM, Diameter 108MM, Discharge Time less than 8 Secs, Controllable discharge mechanism(Squeeze grip with easy snap safety seal), Range minimum 2 meters, applicable on Class A,B,C and electrically started Fire, A Rating 1A, B Rating 8B, Can construction : Deep drawn and Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster power coatng, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, HOM complete as per specifications. complete.

26

2872

74672

... More
Man907 - Supply of 2 bucket stand along with 2 buckets.

8

469

3752

... More
Man908 - HVAC WORKS: AIRCONDITIONING SYSTEMS: VRV VRF units Air Conditioning Units : Supply, Installation, Testing and Commissioning of Variable Refrigerant Flow modular type airconditioning system complete with indoor and outdoor units with individual controller as per the following capacities of the IDU and ODU. VRF AIR CONDITIONING UNITS Efficiency as per ASHRAE 90.1 (HiCOP units) COP to be specified along with quote. VRV OUTDOOR UNITS: Micro proceessor controlled VRV Outdoor unit with hermetically sealed Scroll Rotary inverter type compressor and pre charged with HFC refrigerant ( capable of modulating capacity from 20percent 100percent. The unit shall be completely factory wired and tested with necessary controls. Unit shall be equipped with oil recovery system to ensure stable operation with long refrigerant piping. The unit shall be factory charged and any topup gas oil required for first charge should be included in the individual price quoted below. This shall include the nitrogen leak testing, oil charging, vaccumisation. The unit shall be compatible for (Modbus Bacnet Lonwork) BMS operation. VRF with each module of outdoor unit should have multiple compressors and minimum 50percent of them should be inverter type compressor all inverter type compressors. Vendor to submit detailed derating calculations of the VRV unit, Equipment performance data, Refrigerant piping and control schemes along with the offer. The ODU shall have condenser fan capable of minmum 7 speeds for saving energy at various loading conditions. The outdoor unit shall be weather proof casing constructed from heavy gauge mild steel panels and coated with anticorrosive enamel finish. Aluminum fins for condenser coils shall be provided with anticorrosive Hydrophilic coating equivalent. ODU shall be mounted on the suitable Vibration isolators. The outdoor and indoor units shall be integrated with special super wiring system with a central monitoring remote controller into one common wiring. No false ceiling is provided hence workmanship shall be of highest quality : 6 HP

1

135000

135000

... More
Man909 - VRV VRF units Air Conditioning Units : Supply, Installation, Testing and Commissioning of Variable Refrigerant Flow modular type airconditioning system complete with indoor and outdoor units with individual controller as per the following capacities of the IDU and ODU. VRF AIR CONDITIONING UNITS Efficiency as per ASHRAE 90.1 (HiCOP units) COP to be specified along with quote. VRV OUTDOOR UNITS: Micro proceessor controlled VRV Outdoor unit with hermetically sealed Scroll Rotary inverter type compressor and pre charged with HFC refrigerant ( capable of modulating capacity from 20percent 100percent. The unit shall be completely factory wired and tested with necessary controls. Unit shall be equipped with oil recovery system to ensure stable operation with long refrigerant piping. The unit shall be factory charged and any topup gas oil required for first charge should be included in the individual price quoted below. This shall include the nitrogen leak testing, oil charging, vaccumisation. The unit shall be compatible for (Modbus Bacnet Lonwork) BMS operation. VRF with each module of outdoor unit should have multiple compressors and minimum 50percent of them should be inverter type compressor all inverter type compressors. Vendor to submit detailed derating calculations of the VRV unit, Equipment performance data, Refrigerant piping and control schemes along with the offer. The ODU shall have condenser fan capable of minmum 7 speeds for saving energy at various loading conditions. The outdoor unit shall be weather proof casing constructed from heavy gauge mild steel panels and coated with anticorrosive enamel finish. Aluminum fins for condenser coils shall be provided with anticorrosive Hydrophilic coating equivalent. ODU shall be mounted on the suitable Vibration isolators. The outdoor and indoor units shall be integrated with special super wiring system with a central monitoring remote controller into one common wiring. No false ceiling is provided hence workmanship shall be of highest quality : 8 HP

1

168000

168000

... More
Man910 - VRV VRF units Air Conditioning Units : Supply, Installation, Testing and Commissioning of Variable Refrigerant Flow modular type airconditioning system complete with indoor and outdoor units with individual controller as per the following capacities of the IDU and ODU. VRF AIR CONDITIONING UNITS Efficiency as per ASHRAE 90.1 (HiCOP units) COP to be specified along with quote. VRV OUTDOOR UNITS: Micro proceessor controlled VRV Outdoor unit with hermetically sealed Scroll Rotary inverter type compressor and pre charged with HFC refrigerant ( capable of modulating capacity from 20percent 100percent. The unit shall be completely factory wired and tested with necessary controls. Unit shall be equipped with oil recovery system to ensure stable operation with long refrigerant piping. The unit shall be factory charged and any topup gas oil required for first charge should be included in the individual price quoted below. This shall include the nitrogen leak testing, oil charging, vaccumisation. The unit shall be compatible for (Modbus Bacnet Lonwork) BMS operation. VRF with each module of outdoor unit should have multiple compressors and minimum 50percent of them should be inverter type compressor all inverter type compressors. Vendor to submit detailed derating calculations of the VRV unit, Equipment performance data, Refrigerant piping and control schemes along with the offer. The ODU shall have condenser fan capable of minmum 7 speeds for saving energy at various loading conditions. The outdoor unit shall be weather proof casing constructed from heavy gauge mild steel panels and coated with anticorrosive enamel finish. Aluminum fins for condenser coils shall be provided with anticorrosive Hydrophilic coating equivalent. ODU shall be mounted on the suitable Vibration isolators. The outdoor and indoor units shall be integrated with special super wiring system with a central monitoring remote controller into one common wiring. No false ceiling is provided hence workmanship shall be of highest quality : 10HP

1

195500

195500

... More
Man911 - VRV VRF units Air Conditioning Units : Supply, Installation, Testing and Commissioning of Variable Refrigerant Flow modular type airconditioning system complete with indoor and outdoor units with individual controller as per the following capacities of the IDU and ODU. VRF AIR CONDITIONING UNITS Efficiency as per ASHRAE 90.1 (HiCOP units) COP to be specified along with quote. VRV OUTDOOR UNITS: Micro proceessor controlled VRV Outdoor unit with hermetically sealed Scroll Rotary inverter type compressor and pre charged with HFC refrigerant ( capable of modulating capacity from 20percent 100percent. The unit shall be completely factory wired and tested with necessary controls. Unit shall be equipped with oil recovery system to ensure stable operation with long refrigerant piping. The unit shall be factory charged and any topup gas oil required for first charge should be included in the individual price quoted below. This shall include the nitrogen leak testing, oil charging, vaccumisation. The unit shall be compatible for (Modbus Bacnet Lonwork) BMS operation. VRF with each module of outdoor unit should have multiple compressors and minimum 50percent of them should be inverter type compressor all inverter type compressors. Vendor to submit detailed derating calculations of the VRV unit, Equipment performance data, Refrigerant piping and control schemes along with the offer. The ODU shall have condenser fan capable of minmum 7 speeds for saving energy at various loading conditions. The outdoor unit shall be weather proof casing constructed from heavy gauge mild steel panels and coated with anticorrosive enamel finish. Aluminum fins for condenser coils shall be provided with anticorrosive Hydrophilic coating equivalent. ODU shall be mounted on the suitable Vibration isolators. The outdoor and indoor units shall be integrated with special super wiring system with a central monitoring remote controller into one common wiring. No false ceiling is provided hence workmanship shall be of highest quality : 12HP

1

231500

231500

... More
Man912 - VRV VRF units Air Conditioning Units : Supply, Installation, Testing and Commissioning of Variable Refrigerant Flow modular type airconditioning system complete with indoor and outdoor units with individual controller as per the following capacities of the IDU and ODU. VRF AIR CONDITIONING UNITS Efficiency as per ASHRAE 90.1 (HiCOP units) COP to be specified along with quote. VRV OUTDOOR UNITS: Micro proceessor controlled VRV Outdoor unit with hermetically sealed Scroll Rotary inverter type compressor and pre charged with HFC refrigerant ( capable of modulating capacity from 20percent 100percent. The unit shall be completely factory wired and tested with necessary controls. Unit shall be equipped with oil recovery system to ensure stable operation with long refrigerant piping. The unit shall be factory charged and any topup gas oil required for first charge should be included in the individual price quoted below. This shall include the nitrogen leak testing, oil charging, vaccumisation. The unit shall be compatible for (Modbus Bacnet Lonwork) BMS operation. VRF with each module of outdoor unit should have multiple compressors and minimum 50percent of them should be inverter type compressor all inverter type compressors. Vendor to submit detailed derating calculations of the VRV unit, Equipment performance data, Refrigerant piping and control schemes along with the offer. The ODU shall have condenser fan capable of minmum 7 speeds for saving energy at various loading conditions. The outdoor unit shall be weather proof casing constructed from heavy gauge mild steel panels and coated with anticorrosive enamel finish. Aluminum fins for condenser coils shall be provided with anticorrosive Hydrophilic coating equivalent. ODU shall be mounted on the suitable Vibration isolators. The outdoor and indoor units shall be integrated with special super wiring system with a central monitoring remote controller into one common wiring. No false ceiling is provided hence workmanship shall be of highest quality : 24HP (Combination of 12HP+12HP)

1

536000

536000

... More
Man913 - VRV VRF Ceiling Mounted Ductable Units : Supply, Installation, Testing and Commissioning of Ceiling mounted indoor units, Galvanized steel casing ( High external static) with cooling coil, electronic expansion valve and multispeed fan motor. The fan shall be aerodynamically designed turbo multiblade type. The blower shall be Statically and dynamically balanced for silent operation. The filters shall be Plasma and synthetic washable media type arranged for convenient cleaning and replacement, built in drain pump. The drain pan shall be fabricated out of heavy sheet steel insulated, 6mm expanded polythylene sheet with Anit Bacterial treatment. (Low Operating noise level to be considered for the units) suitable Vibration Isolators flexible canvas connection between indoor unit and duct. (a) Nominal capacity: 10.0TR, Dehumidified Air Qty : 4000CFM.

1

145050

145050

... More
Man914 - Cordless Wireless Remote Controllers which shall be sleek and self diagnostic type with necessary Controller.

1

3850

3850

... More
Man915 - VRV VRF Ceiling Mounted 4 Way Cassette Unit Round Flow Type Units : Supply, Installation, Testing and Commissioning of Ceiling mounted 4way Type Round Flow Type cassette indoor units with cooling coil, electronic expansion valve and multispeed fan motor, with individual louver Airflow direction setting arrangement. The fan shall be aerodynamically designed turbo multiblade type. The blower shall be Statically and dynamically balanced for silent operation. The filters shall be Plasma and synthetic washable media type arranged for convenient cleaning and replacement, built in drain pump suitable to lift water not less than 600mm. The drain pan shall be fabricated out of heavy sheet steel insulated with 6mm expanded polythylene sheet. (Mounting of Units is on exposd concrete ceiling No false ceiling) : Nominal capacity: 1.1TR, Dehumidified Air Qty : 400CFM

2

39500

79000

... More
Man916 - VRV VRF Ceiling Mounted 4 Way Cassette Unit Round Flow Type Units : Supply, Installation, Testing and Commissioning of Ceiling mounted 4way Type Round Flow Type cassette indoor units with cooling coil, electronic expansion valve and multispeed fan motor, with individual louver Airflow direction setting arrangement. The fan shall be aerodynamically designed turbo multiblade type. The blower shall be Statically and dynamically balanced for silent operation. The filters shall be Plasma and synthetic washable media type arranged for convenient cleaning and replacement, built in drain pump suitable to lift water not less than 600mm. The drain pan shall be fabricated out of heavy sheet steel insulated with 6mm expanded polythylene sheet. (Mounting of Units is on exposd concrete ceiling No false ceiling) : Nominal capacity: 1.6TR, Dehumidified Air Qty : 600CFM

2

40500

81000

... More
Man917 - VRV VRF Ceiling Mounted 4 Way Cassette Unit Round Flow Type Units : Supply, Installation, Testing and Commissioning of Ceiling mounted 4way Type Round Flow Type cassette indoor units with cooling coil, electronic expansion valve and multispeed fan motor, with individual louver Airflow direction setting arrangement. The fan shall be aerodynamically designed turbo multiblade type. The blower shall be Statically and dynamically balanced for silent operation. The filters shall be Plasma and synthetic washable media type arranged for convenient cleaning and replacement, built in drain pump suitable to lift water not less than 600mm. The drain pan shall be fabricated out of heavy sheet steel insulated with 6mm expanded polythylene sheet. (Mounting of Units is on exposd concrete ceiling No false ceiling) : Nominal capacity: 2.0TR, Dehumidified Air Qty : 800CFM

4

42850

171400

... More
Man918 - Cordless Wireless Remote Controllers which shall be sleek and self diagnostic type FOR Cassette unit type.

8

4150

33200

... More
Man919 - Cassette unit Decoration Panel Colour of the panel shall be as approved by Architect Client.

8

5700

45600

... More
Man920 - VRV VRF Wall Mounted Hi WallUnit : Supply, installation, testing and commissioning of following minimum capacity VRV VRF High wall type Indoor unit equipped with washable synthetic media prefilter, fan section with low noisefan dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitablefor operation on 230 V 10percent, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System : Nominal capacity: 1.0TR, Dehumidified Air Qty : 400CFM

2

36500

73000

... More
Man921 - VRV VRF Wall Mounted Hi WallUnit : Supply, installation, testing and commissioning of following minimum capacity VRV VRF High wall type Indoor unit equipped with washable synthetic media prefilter, fan section with low noisefan dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitablefor operation on 230 V 10percent, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System : Nominal capacity: 1.6TR, Dehumidified Air Qty : 600CFM

4

38450

153800

... More
Man922 - VRV VRF Wall Mounted Hi WallUnit : Supply, installation, testing and commissioning of following minimum capacity VRV VRF High wall type Indoor unit equipped with washable synthetic media prefilter, fan section with low noisefan dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitablefor operation on 230 V 10percent, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System : Nominal capacity: 2.0TR, Dehumidified Air Qty : 800CFM

2

41250

82500

... More
Man923 - Supply and Installation of Floor mounted Double skin Air handling Unit with thermal break profile, 45 mm thick PUF Panel, DIDW backward curved fans, MERV8 Prefilter, Limit switches, Removable Access door, Return air and fresh air damper and 6 row interwind DX Cooling Coil of following capacity AHU Capacity : 20 TR , 8000 Cfm with 50 mm total static connected with 2 nos of 24HP VRF ODU Mixing Box Required. (Thermal break profile: Required, SA RA FA dampers shall be of GI aerofoil design, Motor Efficiency and FEG inline with ASHRAE 90.12013.

1

365000

365000

... More
Man924 - Bypass Starter panel for Above AHU

1

24800

24800

... More
Man925 - VFD for Above AHU

1

38500

38500

... More
Man926 - Supply of AHU kits to connect VRF ODU with third party AHU (Dx Controller + Expansion Valve Kit) Number of unit should be suitable to unit capacity.

1

48000

48000

... More
Man927 - Supply of central remote controller

1

128000

128000

... More
Man928 - Supply and Installation of Power protection panel for the VRF outdoor units with suitable inter connecting cable from vrf indoor unit to vrf outdoor unit complete and as required.

2

31500

63000

... More
Man929 - Lifting and Shifting of AHU and VRF Outdoor and Indoor units.

1

150000

150000

... More
Man930 - Supply and installation of suitable refnut joints to connect the VRF indoor units with outdoor unit.

2

21500

43000

... More
Man931 - 24HP Communication Kit

1

15800

15800

... More
Man932 - REFRIGERANT PIPING: PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 41.28mm (OD)

40

1580

63200

... More
Man933 - PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings: 38.1mm (OD)

4

1480

5920

... More
Man934 - PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 34.93mm (OD)

4

1480

5920

... More
Man935 - PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 31.8mm (OD)

4

1310

5240

... More
Man936 - PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 28.58mm (OD)

60

1310

78600

... More
Man937 - PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 25.4mm (OD)

4

1210

4840

... More
Man938 - PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 22.23mm (OD)

60

1050

63000

... More
Man939 - PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 19.05mm (OD)

4

900

3600

... More
Man940 - PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 15.88mm (OD)

60

750

45000

... More
Man941 - PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 12.70mm (OD)

60

580

34800

... More
Man942 - REFRIGERANT PIPING: PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 41.28mm (OD)

20

1400

28000

... More
Man943 - PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 38.1mm (OD)

1

1300

1300

... More
Man944 - PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 34.93mm (OD)

1

1300

1300

... More
Man945 - PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 31.8mm (OD)

1

1150

1150

... More
Man946 - PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 28.58mm (OD)

70

1150

80500

... More
Man947 - PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings: 25.4mm (OD)

1

1050

1050

... More
Man948 - PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 22.23mm (OD)

80

900

72000

... More
Man949 - PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 19.05mm (OD)

1

790

790

... More
Man950 - PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 15.88mm (OD)

140

655

91700

... More
Man951 - PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 12.70mm (OD)

140

490

68600

... More
Man952 - PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 9.53mm (OD)

90

390

35100

... More
Man953 - PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 6.35mm (OD)

90

370

33300

... More
Man954 - CABLE TRAY FOR PIPE SUPPORTING : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5percent, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc as required. Cable tray lengths to be estimated by vendor : 600 mm width X 50 mm depth X 2.0 mm thickness

40

765

30600

... More
Man955 - CABLE TRAY FOR PIPE SUPPORTING : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5percent, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc as required. Cable tray lengths to be estimated by vendor: 450 mm width X 62.5 mm depth X 2.0 mm thickness

40

700

28000

... More
Man956 - CABLE TRAY FOR PIPE SUPPORTING : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5percent, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc as required. Cable tray lengths to be estimated by vendor : 300 mm width X 62.5 mm depth X 2.0 mm thickness

90

621

55890

... More
Man957 - CABLE TRAY FOR PIPE SUPPORTING : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5percent, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc as required. Cable tray lengths to be estimated by vendor: 150 mm width X 50 mm depth X 1.6 mm thickness

110

531

58410

... More
Man958 - Supply of Multi Kits Connection Kits Refnet joints branch distributors for indoor and outdoor units.

40

1150

46000

... More
Man959 - Gas charging, Testing and commissioning with R410A

110

1050

115500

... More
Man960 - Supply and installation of GI conduit for the interconecting above cable between indoor units and outdoor units, between indoor units and remote controllers.

4

27500

110000

... More
Man961 - VRV CONTROLLERS : Master Central Controller Central Remote Controller Master Central Controller Central Remote Controller with open protocol as specified below and in Technical Specifications suitable for automatic operation of all indoor and outdoor units. The central controller shall have a liquid crystal display (LCD) and have the capability of controlling all indoor and outdoor units individually, in groups and unanimously. The central controller shall have the unique capability of arranging indoor units into groups (up to 16 groups per network). The central controller shall be time clocked by the 7dayYear round programmable timer supplied by the manufacturer or by an external time clock (supplied by others). When used in conjunction with the 7day programmable timer then different programme on off times for each group of indoor units shall be available. Incase of BMS system not in operation for any reason, the Master Controller   Central Controller shall be capable to work on stand alone basis and should be able to indicate and control all indoor and outdoor units as specified. The system shall have the capability to connect to external printer.

4

54450

217800

... More
Man962 - Interface Unit between VRV VRF and BMS : Intelligent Central Touch controller to control (switchin on and switching off with read write permission) and monitor ON OFF status of all the IDUs from one place with control wiring from the central controllers to individual ODUs complete with Modbus, Bacnet and Lonwork gateway suitable for third party BMS Integration.

4

135250

541000

... More
Man963 - Supply, fabrication and installation of GI Ducting Along with flanges,supports and all fixing materials : Factory fabricated Galvanized sheet metal duct work including bends, stiffners, flanges, guide vanes and supporting system (with fully threaded G.I. rods and M.S. slotted angles upto 600mm and above with 25x25x3 or higher MS to consider) complete with flanges, gaskets and supports etc., ducts to be fabricated erected as per SMACNA. The minimum weight of zinc coating (total on both sides) shall be 120 GSM as per latest version of IS:277. Interlocking system from one branch duct to other branch duct with TDF Flanges or to be specified : Thickness 0.63 mm Sheet 24 gauge

300

1901

570465

... More
Man964 - Supply,fabrication and installation of GI Ducting Along with flanges,supports and all fixing materials : Factory fabricated Galvanized sheet metal duct work including bends, stiffners, flanges, guide vanes and supporting system (with fully threaded G.I. rods and M.S. slotted angles upto 600mm and above with 25x25x3 or higher MS to consider) complete with flanges, gaskets and supports etc., ducts to be fabricated erected as per SMACNA. The minimum weight of zinc coating (total on both sides) shall be 120 GSM as per latest version of IS:277. Interlocking system from one branch duct to other branch duct with TDF Flanges or to be specified : Thickness 0.80 mm Sheet 22 gauge

275

2227

612438.75

... More
Man965 - Supply,fabrication and installation of GI Ducting Along with flanges,supports and all fixing materials : Factory fabricated Galvanized sheet metal duct work including bends, stiffners, flanges, guide vanes and supporting system (with fully threaded G.I. rods and M.S. slotted angles upto 600mm and above with 25x25x3 or higher MS to consider) complete with flanges, gaskets and supports etc., ducts to be fabricated erected as per SMACNA. The minimum weight of zinc coating (total on both sides) shall be 120 GSM as per latest version of IS:277. Interlocking system from one branch duct to other branch duct with TDF Flanges or to be specified : Thickness 1.00 mm Sheet 20 gauge

150

2410

361500

... More
Man966 - Supply,fabrication and installation of GI Ducting Along with flanges,supports and all fixing materials : Factory fabricated Galvanized sheet metal duct work including bends, stiffners, flanges, guide vanes and supporting system (with fully threaded G.I. rods and M.S. slotted angles upto 600mm and above with 25x25x3 or higher MS to consider) complete with flanges, gaskets and supports etc., ducts to be fabricated erected as per SMACNA. The minimum weight of zinc coating (total on both sides) shall be 120 GSM as per latest version of IS:277. Interlocking system from one branch duct to other branch duct with TDF Flanges or to be specified : Thickness 1.25 mm Sheet 18 gauge

10

2610

26100

... More
Man967 - Gripple Support : Supply, Fabrication, installation and testing of Gripple Hangers, Supports and Modular system -Wire rope Supports Gripple (double channel wedge lock, unlocking device should not be integral part of grip for added safety) complete with end fixing. Wire Hangers shall be independently tested by reputed third party testing organization to sustain safe working load for 120min at elevated temperature of 175 deg. C or above. System shall be in accordance with the approved shop drawings and as required by the specifications. Kit including wire for safe working to be considered, Precrimpted Wire rope to be used along with GHF kit and Accessories for installation complete

2

13150

26300

... More
Man968 - VOLUME CONTROL DAMPER : G.I Volume Control Damper, Motorized (ONOFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room Make: SYSTEMAIR, CAMDUCT, CARYAIRE.

5.5

4300

23650

... More
Man969 - Damper Actuator

10

4307

43070

... More
Man970 - VOLUME CONTROL DAMPER FIRE DAMPER : Supplying Fixing, testing and commissioning of fire dampers in supply air dut main branch and return air path as and where required of required sizes i c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specification Make: SYSTEMAIR, CARYAIRE, JAYDE UTILITY, AIRMASTER. Fire Damper

3

6854

20562

... More
Man971 - Actuator 10 Nm Make: Johnson controls, BELIMO.

5

6307

31535

... More
Man972 - Control panel and Temprature Sensor

6

2285

13710

... More
Man973 - LINEAR GRILLES Diffusers : Supply and fixing of powder coated extruded alluminium grill suitable for supply return air including all fixing hardware etc,. Complete. Color of the grille as per approval of Architect Client: 6inches excluded aluminium grill with 15 deg to 30 deg louvers

40

1787

71484

... More
Man974 - Supply and fixing of powder coated extruded alluminium grill suitable for supply return air including all fixing hardware etc,. Complete. Color of the grille as per approval of Architect Client : 6inches aluminium spot grill with 15 deg to 30 deg louvers of size (450X150)

4

800

3200

... More
Man975 - Supply and fixing of powder coated extruded alluminium grill suitable for supply return air including all fixing hardware etc,. Complete. Color of the grille as per approval of Architect Client: 6inches aluminium spot grill with 15 deg to 30 deg louvers of size (600X150)

4

920

3680

... More
Man976 - Powder coated, extruded aluminium, supply air Jet diffusers with adjustable vanes of aluminium construction of 250mm dia. The diffuser shall be mounted in the GI box, with inlet connector suitable for flexible duct. GI Box and Flexible duct quantified seperately.

30

6480

194400

... More
Man977 - Spill Air Boxes Expansion Plenum 450x 450 x 400 mm High Sheet Metal Spill air boxes made out of 26 GI sheet for connecting the diffuser outlet and flexible

30

1300

39000

... More
Man978 - Supply and installtion of Powder coated aluminium diffusers of size 595x595mm for supply and return air.

30

5331

159957

... More
Man979 - FRESH AIR LOUVER : Supply, installation and testing of Aluminium opposed blades fresh air of inlet louvers, bird screen, volume control damper in accordance with approved shop drawings and specifications.

2

11250

22500

... More
Man980 - G.I collar dampers with opposed blades as follows. Rate per sq.mt of face area.

4

2755

11020.8

... More
Man981 - ACOUSTIC LINING (DUCTS): Supply, Installation and Acoustic lining of ducting with 15mm thick open cell nitrile rubber insulation Class inches1inches existing surface, adhesive (K414), accessories with aluminium tape complete as required.

200

1050

210000

... More
Man982 - Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg cu.m resin bonded glass fiber insulation friction fixed in 610mm X 610mm frame work made of 25 X 50 X 50 X 50 X 25 mm made out of 0.6mm thick GI sheet u shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.

75

864

64800

... More
Man983 - THERMAL INSULATION: Supply and fixing of Thermal insulation of following thickness aluminium foil of mat finish closed cell Nitrile rubber (Class inchesOinches) insulation on existing duct after applying two coats of cold setting adhesive (CPRX compound). The joints shall sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. Make: KFLEX, SUPREME, PARAMOUNT : 9mm

325

620

201500

... More
Man984 - THERMAL INSULATION: Supply and fixing of Thermal insulation of following thickness aluminium foil of mat finish closed cell Nitrile rubber (Class inchesOinches) insulation on existing duct after applying two coats of cold setting adhesive (CPRX compound). The joints shall sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. Make: KFLEX, SUPREME, PARAMOUNT : 15mm

350

728

254800

... More
Man985 - Supply and installation Underdeck (Insulation) of specified thickness of Elastromeric Rubber Insulation Joints should be sealed with 50 mm wide 3 mm thick self adhesive tape Class inchesOinches Material(16mm thick) Make: KFLEX, SUPREME, PARAMOUNT.

1100

560

616000

... More
Man986 - Supply and Instalation of UPVC Drain water piping with Closed Cell Nitrile rubber insulation of 6mm with suitable clamping and bonding material as per ECBC Complaince: 25mm UPVC

140

260

36400

... More
Man987 - Supply and Instalation of UPVC Drain water piping with Closed Cell Nitrile rubber insulation of 6mm with suitable clamping and bonding material as per ECBC Complaince : 40mm UPVC

70

350

24500

... More
Man988 - Supply and Instalation of UPVC Drain water piping with Closed Cell Nitrile rubber insulation of 6mm with suitable clamping and bonding material as per ECBC Complaince : 50mm UPVC

50

410

20500

... More
Man989 - All necessary civil works like cutting and chasing of walls floor glass etc. and make them good thereof.

6

20000

120000

... More
Man990 - Supplying of…TR split Air conditioners suitable for operation on A C supply single phase 50 Hz 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded chordless). 5 Star Rating : 1.0 TR

3

43791

131373.9

... More
Man991 - Supplying of…TR split Air conditioners suitable for operation on A C supply single phase 50 Hz 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded chordless). 5 Star Rating : 1.5 TR

2

50067

100134.3

... More
Man992 - Supplying of…TR split Air conditioners suitable for operation on A C supply single phase 50 Hz 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded chordless). 5 Star Rating : 2.0 TR

2

56750

113500.8

... More
Man993 - Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support up to 3.0 ton split cassette type A C.

7

3333

23336.25

... More
Man994 - Supplying and installation of insulated refrigrent copper tubing of 5 8inches and 3 8inches with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit. Leak testing oil and gas charging for additional piping length of tube : Copper Piping

140

1626

227703

... More
Man995 - Hi wall suitable size Cabling

180

1667

300060

... More
Man996 - Insulated Drain piping with 9mm thick nitrile rubber

50

160

8000

... More
Man997 - Stabilizer 3kva, 4kva and 5kva as required

7

2150

15050

... More
Man998 - Extra for Fabrication supply and fixing of Stand fabricated using slotted angle L.angle of size 6mm x 50mm for mounting outdoor Indoor AC unit.

35

120

4200

... More
Man999 - Supplying and filling refrigerent (F22 F 12) for air conditioning equipments. Which includes the labour and Nitrogen gas for pressure and leak testing.

60

635

38115

... More
Man1000 - VENTILATION SYSTEMS (TOILET EXHAUST SYSTEM) : Supply, Installation, Testing and Commissioning of the following items as per specifications, drawings and equipment schedule. Supply fans and Exhaust fans, Single skin ventilation unit with backward curved forward curved centrifugal DIDW fan, cleanable pre filter 90percent effieciency down to 10 micron and outlet dampers with fire retarding canvas connection. Outlet velocity shall be less than 9.5 m s and Suitable for out door applications. (Static pressures given in schedules are for guidance only. The Contractor shall calculate the external and internal static pressure of all fans and submit the same for approval prior to ordering. Any increase of fan static motor power required shall be at no additional cost to client.) : 1200 CFM and 30 mm.wc ESP (Exhaust Air)

8

27800

222400

... More
Man1001 - VENTILATION SYSTEMS (TOILET EXHAUST SYSTEM) : Supply, Installation, Testing and Commissioning of the following items as per specifications, drawings and equipment schedule. Supply fans and Exhaust fans, Single skin ventilation unit with backward curved forward curved centrifugal DIDW fan, cleanable pre filter 90percent effieciency down to 10 micron and outlet dampers with fire retarding canvas connection. Outlet velocity shall be less than 9.5 m s and Suitable for out door applications. (Static pressures given in schedules are for guidance only. The Contractor shall calculate the external and internal static pressure of all fans and submit the same for approval prior to ordering. Any increase of fan static motor power required shall be at no additional cost to client.) : 1500 CFM and 30 mm.wc ESP (Exhaust Air)

5

24950

124750

... More
Man1002 - Insulated Flexible Ducts with Inner core made of Aluminum laminate and Polyester film with latex adhesive supported by helically wound, springsteel wire Outer jacket made of UL 181, Class 1, fibrousglass insulation, Polyethylene vaporbarrier film necessary accossories. Thickness of insulation shall be as per ASHRAE 90.1. Minimum width of the supporting strap to be 25mm. For 150 to 300mm dia (PWD Ele SR 22324 Pg No. 558 of 635 6.29.4)

150

1776

266490

... More
Man1003 - Supply, installation, testing and balancing of square Rectangular Aluminium powder coated Exhaust air diffusers. All diffusers must be multislotted complete with air pattern controller, Removable key. 150mmx150mm Exhaust air.

155

1150

178250

... More
Man1004 - Supply, Installation, Testing and Commissioning of 250mmx250mmx300mm hight diffuser boxes Mixing Boxes made out of 24 g GI sheet suitable for 150mm x 150mm outlet grilles, compete with spigot, supporting chain. (PWD Ele SR 22324 Pg No. 558 of 635 6.29.3)

155

6588

1021256.25

... More
Man1005 - Supply and Installation and Commissioning of 22G GSS Butterfly damper a) 150mm Dia

155

780

120900

... More
Man1006 - Supply, installation, testing and commissing of INLINE FANS for ventilation system. Each fan shall be complete with totally enclosed fan cooled motor drive, motor mount , vibration isolators and suitable weather protection arrangement. Fan static pressure at 20mm and 300CFM.

5

10800

54000

... More
Man1007 - Supply, installation, testing and commissing of INLINE FANS for ventilation system. Each fan shall be complete with totally enclosed fan cooled motor drive, motor mount , vibration isolators and suitable weather protection arrangement. Fan static pressure at 20mm and 600CFM

5

14800

74000

... More
Man1008 - Supply and fixing of powder coated extruded alluminium grill suitable for supply return air including all fixing hardware etc,. Complete. Color of the grille as per approval of Architect Client : 6inches aluminium spot grill with 15 deg to 30 deg louvers of size (200X100)

5

600

3000

... More
Man1009 - Door Air Curtains (DAC) : Air Velocity : 25 m s at the mouth of the Air Curtain and 4 m s at the floor, Sound Level 45DB at 1Meter above the Ground Level, 1 Phase Motor, 220 Volts, 50 Hz, 1440 RPM, Double end shaft Balanced on sealed Ball Bearings, Impellers 220 mm Dia, 42 Blades, 485 635 mm in length, Grade SS304, Stainless Steel Make, Dynamically balanced, Outer Casing C.R.C.A Sheet, Powder coated and of approved Colour, Louvers M.S.Make, Powder Coated and can be tilted at 7.5 Degrees inside or outside to adjust airflow, Bearings with approved make and sealed ball bearing : Door Air curtain suitable for a door width of 1.8 m. and height of 2.4 m.

9

38600

347400

... More
Man1010 - Door Air Curtains (DAC) : Air Velocity : 25 m s at the mouth of the Air Curtain and 4 m s at the floor, Sound Level 45DB at 1Meter above the Ground Level, 1 Phase Motor, 220 Volts, 50 Hz, 1440 RPM, Double end shaft Balanced on sealed Ball Bearings, Impellers 220 mm Dia, 42 Blades, 485 635 mm in length, Grade SS304, Stainless Steel Make, Dynamically balanced, Outer Casing C.R.C.A Sheet, Powder coated and of approved Colour, Louvers M.S.Make, Powder Coated and can be tilted at 7.5 Degrees inside or outside to adjust airflow, Bearings with approved make and sealed ball bearing : Door Air curtain suitable for a door width of 4.0 m. and height of 2.4 m.

4

86500

346000

... More
Man1011 - Prefabricated plenums made out of PUF panels of approved sizes. The plenums shall be constructed with 24G sheet as outer layer and 24G sheet as inner layer with 50mm thick injected PUF of 2432kg cubmet density. All the corners shall be provided with extruded aluminium section and necessary support for hanging the plenums in all the corners. All the opening made for connecting the ducts shall be sealed properly with necessary aluminium sections and riveted at regular intervals. The outer layer shall be pasteurized finish.

70

2400

168000

... More
Man1012 - Fire proof double layered silicon coated fabric, air tight, water proof (Outdoor type installation), to with stand high temprature, non flamable type, canvass cloth connection for above AHU outlet complete with drawn aluminum flanges on both sides for connection to AHU and duct complete with nuts, bolts etc. as per specification. Make:

5

2951

14755.5

... More
Man1013 - BASEMENT VENTILATION SYSTEMS (FRESH AIR AND EXHAUST SYSTEM) : Supply, installing, testing and commissioning of Ductless Ventilation Jet fans Centrifugal as per specifications for normal ventilation and Smoke Extraction application. The complete fan assembly with its Casing, impeller and motor (not only the motor) shall be imported from manufacturer and certified as tested for 300 Deg C for 2 hours operation. The Jet fans casing shall be made of Hot Dipped Galvanized Steel. The Motorshall be dual speed and run on the electrical power suitable for 415V 3 Ph 50Hz. The Jet fans shall be of 3000 1500 CFM capacity.The Jet fan shallbe as per technical specification and of approved make Nicotra,Systemair, Greenheck.

18

48700

876600

... More
Man1014 - CFD Analysis ( for basement for CO2 simulation)

1

110000

110000

... More
Man1015 - CO Sensors: Supply of CO Sensors shall be designed to detect CO gas in the air with sensing range between 0300 ppm with high accuracy at low connection( 1 Sensor for 2 fans). Basement 1.

9

13210

118890

... More
Man1016 - Supply, Installation, Testing and Commissioning of Electrical Panel with built in PLC for Basement floors with necessary starters for 18Nos of Jet Fans 4Nos of Ventilation fans and 9Nos of CO Sensors. Each of the jet fans (Dual speed motors) for demand ventilation with a logic based on CO detectors. Should also enable auto on off of fans for power saving BASED ON SENSING OF CO LEVEL including all necessary cabling for the above fans and complete. make:GV Control panel, Emmanuel, VKA Power master.

1

352875

352875

... More
Man1017 - Axial Flow Ventilation Fans (Normal and Fire Mode) : SITC of AMCA rated Extract air fans of Tube axial type complete with direct drive fire rated motor with protection, fire rated electrical accessories and other ancillaries. The Fan, motor and each component shall be Fire rated and designed to with stand 300 degree C temperatures for 2 hours in the event of fire. Noise levels of the fans in pollution mode shall be within acceptable levels of 84 dba at 3m distance. Each fan shall be with fixing frame and supports for installation on wall inside the shaft. The scope shall include all ancillary works related to proper fixing of the fans. Fan construction and technical performance shall be with PLC panel for the below with necessary cabling to be considered during quoting in complete compliance with the technical specification issued in Tender.The Fan, motor and each component of the fan shall be Fire rated as per IEC EN NFPA standards and fully meet the F300 time temperature classifications of EN 121013 (250 degree C for 120 minutes). Test Certificates to be produced prior to delivery of the units. Fan motor shall be of 6pole, high efficiency and low noise design. The fan shall be acousticaly treated and Fan supplied with cushy foot(Spring isolator). Accessories , 2 nos of Matching Flanges and 2 Nos fire rated canvas connection. Make Axial flow fan: Nicotra, Systemair, Greenheck : Fan Capacity rating: 11500 23000 CFM at 30 mmwg Static Pressure (Dual Speed Motor)

2

217488

434976

... More
Man1018 - TUBE AXIAL FANS FOR FRESH AIR : Long cased Smokespill Tube Axial fan with AMCA certification (For AIR, SOUND Performance and FEG). The Long casing shall comprise of adjustable blade angles to deliver the design air quantity. The axial fan assembly shall be housed in a casing made of Powder coated Mild Steel, adjustable pitch die cast aluminium impeller (Hub and blades) suitable for 415V 3Ph 50Hz AC supply. Fan position shall be as per the tender drawings. The Motor shall be of TEFC TEOA, IP55 protection, Class F insulation, IE2 efficiency, suitable for 3 phase, 415volts, 50hz power supply. Fan position shall be as per the tender drawings. AMCA certificate to be provided along with technical submittals Long Casing should be made of powder coated Mild Steel. The unit shall be suitable for indoor application with necessary supports with necessary MS channels and threaded rods. Make Axial flow fan: Nicotra, Systemair, Greenheck : 23000 CFM 20 mm wc. ESP. Fresh Air (Motor rating 7.5 Kw 6 Pole)

2

175450

350900



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.