Public Works Department Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Opening Date21 Jan 2025
Closing Date30 Jan 2025
Tender Amount₹ 19,78,084.74 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

  • Tender Id

    PWD/2024-25/BD/WORK_INDENT16607
  • Tender No

    PWD/2024-25/BD/WORK_INDENT16607
  • Tender Authority

    Public Works Department View
  • Purchaser Address

    -
Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
vol-6, Page No.2, I.No.1.3.1 - Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary - 19/20 mm dia 2 mm thick (PWD Electrical SR 2023-24, vol-6, Page No.2, I.No.1.3.1) ---- DTS

150

68

10200

... More
vol-6, Page No.2, I.No.1.3.2 - Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary - 25 mm dia 2 mm thick (PWD Electrical SR 2023-24, vol-6, Page No.2, I.No.1.3.2) ---- DTS

150

79

11850

... More
vol-6, Page No.2, I.No.1.3.3 - Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary - 32 mm dia 2.5 mm thick (PWD Electrical SR 2023-24, vol-6, Page No.2, I.No.1.3.3) ---- DTS

50

99

4950

... More
vol-6, Page No.3, I.No.1.7.1 - Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete - upto 50 mm conduit in brick wall ---- DTS

600

29

17400

... More
vol-6, Page No.3, I.No.1.9.1 - Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely - 20 mm (PWD Electrical SR 2023-24, vol-6, Page No.3, I.No.1.9.1) ---- DTS

60

19

1140

... More
vol-6, Page No.3, I.No.1.9.2 - Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely - 25 mm (PWD Electrical SR 2023-24, vol-6, Page No.3, I.No.1.9.2) ---- DTS

60

22

1320

... More
vol-6, Page No.5, I.No.2.2.1 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet - Short point upto 3m from tapping point to out let via switch (PWD Electrical SR 2023-24, vol-6, Page No.5, I.No.2.2.1) ---- DTS

42

269

11298

... More
vol-6, Page No.5, I.No.2.2.2 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet - Medium point above 3m upto 6m from tapping point to out let via switch (PWD Electrical SR 2023-24, vol-6, Page No.5, I.No.2.2.2) ---- DTS

77

379

29183

... More
vol-6, Page No.5, I.No.2.2.2 - Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet - Long point above 6m upto 10m from tapping point to out let via switch (PWD Electrical SR 2023-24, vol-6, Page No.5, I.No.2.2.2) ---- DTS

18

555

9990

... More
vol-6, Page No.5, I.No.2.2.2 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments - 1.5 mm2 (PWD Electrical SR 2023-24, vol-6, Page No.5, I.No.2.2.2) ---- DTS

750

26

19500

... More
vol-6, Page No.3, I.No.2.3.3 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments - 2.5 mm2 (PWD Electrical SR 2023-24, vol-6, Page No.3, I.No.2.3.3) ---- DTS

1500

42

63000

... More
vol-6, Page No.5, I.No.2.3.4 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments - 4 mm2 (PWD Electrical SR 2023-24, vol-6, Page No.5, I.No.2.3.4) ---- DTS

500

63

31500

... More
vol-6, Page No.5, I.No.2.3.5 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments - 6 mm2 (PWD Electrical SR 2023-24, vol-6, Page No.5, I.No.2.3.5) ---- DTS

300

92

27600

... More
Page No.6, I.No.2.3.5 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments - 10 mm2 (PWD Electrical SR 2023-24, vol-6, Page No.6, I.No.2.3.5) ---- DTS

100

167

16700

... More
vol-6, Page No.8, I.No.3.2 - Supplying and mounting 2 Nos. of 2Way 6 A flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 1293 (PWD Electrical SR 2023-24, vol-6, Page No.8, I.No.3.2) ---- DTS

2

170

340

... More
vol-6, Page No.10, I.No.3.14.6 - Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board - 6A Lamp Holder (PWD Electrical SR 2023-24, vol-6, Page No.10, I.No.3.14.6) ---- DTS

137

71

9727

... More
vol-6, Page No.8, I.No.3.4.1 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 1-2 Way ---- DTS

20

138

2760

... More
vol-6, Page No.8, I.No.3.4.4 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 6 Way ---- DTS

10

220

2200

... More
vol-6, Page No.8, I.No.3.4.5 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 8 Way ---- DTS

25

261

6525

... More
vol-6, Page No.8, I.No.3.4.6 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 10-12 Way ---- DTS

50

319

15950

... More
vol-6, Page No.8, I.No.3.4.7 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 16/18 Way ---- DTS

5

363

1815

... More
vol-6, Page No.8, I.No.3.5.1 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 1 to 2 Module ---- DTS

20

137

2740

... More
vol-6, Page No.8, I.No.3.5.4 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 6 Module ---- DTS

10

234

2340

... More
vol-6, Page No.8, I.No.3.5.5 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 8 Module ---- DTS

25

284

7100

... More
vol-6, Page No.8, I.No.3.5.6 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 10-12 Module ---- DTS

50

344

17200

... More
vol-6, Page No.8, I.No.3.5.7 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - 16-18 Module ---- DTS

5

397

1985

... More
vol-6, Page No.9, I.No.3.6.1 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - 6A One Way Switch ---- DTS

250

102

25500

... More
vol-6, Page No.9, I.No.3.6.2 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - 6A Two Way Switch ---- DTS

2

166

332

... More
vol-6, Page No.9, I.No.3.6.3 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - 6A Three Way socket ---- DTS

150

171

25650

... More
vol-6, Page No.9, I.No.3.6.4 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 - Stepped Fan Regulator Two Module ---- DTS

50

357

17850

... More
vol-6, Page No.9, I.No.3.6.7 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 -16A One Way Switch ---- DTS

15

180

2700

... More
vol-6, Page No.9, I.No.3.6.8 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 -6A Bell Push ---- DTS

2

177

354

... More
vol-6, Page No.9, I.No.3.6.11 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 -6/16A Universal Socket ---- DTS

15

156

2340

... More
vol-6, Page No.9, I.No.3.8 - Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws. ---- DTS

30000

-

12300

... More
vol-6, Page No.9, I.No.3.10.1 - Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size ...... mm conduit using necessary machine screws - 60 mm ---- DTS

50

8

400

... More
vol-6, Page No.9, I.No.3.10.2 - Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size ...... mm conduit using necessary machine screws - 80/90 mm ---- DTS

100

15

1500

... More
vol-6, Page No.17, I.No.5.18.1 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 - 6-32 A SP ---- DTS

30

415

12450

... More
vol-6, Page No.17, I.No.5.18.4 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 - 6-32 A DP ---- DTS

15

739

11085

... More
vol-6, Page No.17, I.No.5.18.7 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 - 6-32 Amps TPN ---- DTS

5

1717

8585

... More
vol-6, Page No.17, I.No.5.18.8 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 - 40 Amps TPN ---- DTS

5

3044

15220

... More
vol-6, Page No.18, I.No.5.19.9 - Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure - III - Double Door - 12 Way SP & N ---- DTS

5

2329

11645

... More
vol-6, Page No.21, I.No.5.45.2 - Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely - SP & N - 20 Amps ---- DTS

5

971

4855

... More
vol-6, Page No.21, I.No.5.45.4 - Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely - TP & N - 30 Amps ---- DTS

5

1700

8500

... More
vol-6, ESCOM SR, Page No.30, I.No.6.2.1 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete - 12" Sweep (300 mm) ---- DTS

2

2969

5938

... More
vol-6, ESCOM SR, Page No.30, I.No.6.3.2 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system - 56" Sweep (1400 mm) Regular model ---- DTS

50

3031

151550

... More
vol-6, ESCOM SR, Page No.43, I.No.11.3.2 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80 Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition - LED light fitting 1 x 4 - 20/22 W ---- DTS

81

690

55890

... More
vol-6, ESCOM SR, Page No.46, I.No.11.8.2 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr Lumen Maintenance of 70, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001 2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. ---- DTS

6

4024

24144

... More
vol-6, ESCOM SR, Page No.47, I.No.11.11.4 - Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition - 9W, 6500K ---- DTS

5

154

770

... More
vol-6, ESCOM SR, Page No.47, I.No.11.11.5 - Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition - 12W, 6500K ---- DTS

4

269

1076

... More
vol-6, ESCOM SR, Page No.56, I.No.13.1.1 - Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket 1x40/2x40 W fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clA, bolts, and nuts and wiring using suitable capacity wires - Using 25 mm dia G.I.Pipe ---- DTS

6

978

5868

... More
vol-6, ESCOM SR, Page No.56, I.No.13.5 - Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. ---- DTS

6

162

972

... More
vol-6, ESCOM SR, Page No.56, I.No.13.7.1 - Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA - On wall/ ceiling / Rafter / Girders ---- DTS

90

122

10980

... More
vol-6, ESCOM SR, Page No.57, I.No.13.10 - Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- DTS

50

171

8550

... More
vol-6, ESCOM SR, Page No.57, I.No.13.12 - Extra length of GI pipe of class B 19mm dia for down rod. ---- DTS

50

197

9850

... More
vol-6, ESCOM SR, Page No.57, I.No.13.14 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. ---- DTS

2

492

984

... More
vol-6, PWD Ele. SR, Page No.15 of 105, I.No.5.12.4 - Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) - 200 Amps ---- DTS

1

15249

15249

... More
vol-6, ESCOM SR, Page No.17, I.No.5.15.9 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism - FOUR POLE - 100 Amps 25 KVA ---- DTS

2

8487

16974

... More
vol-6, ESCOM SR, Page No.17, I.No.5.15.11 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism - FOUR POLE - 160 Amps 25 KA ---- DTS

1

13447

13447

... More
vol-6, Ele SR, Page No.17, I.No.15.16 - Supplying and fixing of Shunt trip suitable for MCCB.CBCT ---- DTS

3

1703

5109

... More
vol-6, Ele SR, Page No.18, I.No.5.21 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. ---- DTS

1

9255

9255

... More
vol-6, Ele SR, Page No.19, I.No.5.27 - Supplying, fixing and wiring rotary selector switch suitable for Ammeter ---- DTS

1

200

200

... More
vol-6, Ele SR, Page No.19, I.No.5.28 - Supplying, fixing and wiring rotary selector switch suitable for Voltmeter ---- DTS

1

160

160

... More
vol-6, Ele SR, Page No.19, I.No.5.29 - Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter ---- DTS

1

1425

1425

... More
vol-6, Ele SR, Page No.19, I.No.5.33 - Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- DTS

1

9315

9315

... More
vol-6, Ele SR, Page No.19, I.No.5.34 - Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. ---- DTS

1

562

562

... More
vol-6, Ele SR, Page No.19, I.No.5.38 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C. ---- DTS

3

515

1545

... More
vol-6, Ele SR, Page No.19, I.No.5.40.1 - Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete - 100 A 4 x 30 x 6 mm Aluminium Strips ---- DTS

1

2465

2465

... More
vol-6, Ele SR, Page No.19, I.No.5.41.2 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint - 50 x 50 x 6 mm ---- DTS

15

395

5925

... More
vol-6, Ele SR, Page No.19, I.No.5.42.1 - Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete - 14 SWG ---- DTS

125000

-

62500

... More
Vol-6, ESCOM SR, Page No.13, I.No.32.12 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 - 50 Sqmm, 4 Core, (17 GI Strips - 4 x 0.8 mm) ---- DTS

0.2

207194

41438.8

... More
Vol-6, ESCOM SR, Page No.13, I.No.32.05 - 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 - 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) ---- DTS

0.1

141842

14184.2

... More
Vol-6, ESCOM SR, Page No.13, I.No.21.05 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staf - 2.5 to 25 Sqmm LT CABLE ---- DTS

0.1

20886

2088.6

... More
Vol-6, ESCOM SR, Page No.13, I.No.21.06 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staf - 35 to 95 Sqmm LT CABLE ---- DTS

0.3

31139

9341.7

... More
Vol-1, common civil SR, Page No.6, I.No.1.6.1 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposingoff or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. ---- DTS

0.1

484

48.4

... More
Vol-6, ESCOM SR, Page No.30, I.No.66.04 - HDPE/PLB Pipe 50/42 mm ---- DTS

0.3

85014

25504.2

... More
vol-6, ESCOM SR, Page No.26, I.No.59.02 - Heavy Duty Copper Terminal Long Barrel - 35 Sqmm Copper Terminal, Apprx Wt: 17 Gm ---- DTS

16

40

640

... More
vol-6, ESCOM SR, Page No.26, I.No.59.03 - Heavy Duty Copper Terminal Long Barrel - 50 Sqmm Copper Terminal, Apprx Wt: 26 Gm ---- DTS

16

58

928

... More
vol-6, ESCOM SR, Page No.28, I.No.63.03 - Brass Cable Gland - 40 mm ---- DTS

8

148

1184

... More
Vol-6, Ele SR, Page No.54, I.No.12.56 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- DTS

5

3510

17550



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.