Public Works Department Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Public Works Department - PWD Tender

Opening Date16 Mar 2024
Closing Date25 Mar 2024
Tender Amount₹ 25,41,143.9 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Vol-2 P-188 I-19.12.2 - Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer-in-charge. of area beyond 3 m² ---- Work Should be carried out at the site as per the direction of Engineer incharge

51.12

262

13393.44

... More
Vol-2 P-110 I-12.90 - Providing & fixing of 3 track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets grey colour having solated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 108mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). ---- Work Should be carried out at the site as per the direction of Engineer incharge

28.8

6734

193939.2

... More
Vol-2 P-109 I-12.85 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- Work Should be carried out at the site as per the direction of Engineer incharge

3.6

5719

20588.4

... More
Vol-2 P-99 I-12.12 - Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications. ---- Work Should be carried out at the site as per the direction of Engineer incharge

0.5

124202

62101

... More
Vol-2 P-100 I-12.15 - Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures). ---- Work Should be carried out at the site as per the direction of Engineer incharge

20.16

6897

139043.52

... More
Vol-2 P-46 I-8.33.2 - Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out at the site as per the direction of Engineer incharge

20.16

138

2782.08

... More
Vol-2 P-104 I-12.55.2 - Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. ---- Work Should be carried out at the site as per the direction of Engineer incharge

16.2

2040

33048

... More
Vol-2 P-104 I-12.54 - Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. ---- Work Should be carried out at the site as per the direction of Engineer incharge

61.2

318

19461.6

... More
Vol-1 P-15 I-2.5.2 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ---- Work Should be carried out at the site as per the direction of Engineer incharge

0.43

6843

2942.49

... More
Vol-1 P-112 I-14 - Formwork,Centring & Scaffolding 60% for Roof Beams and Lintel ---- Work Should be carried out at the site as per the direction of Engineer incharge

0.43

4105

1765.494

... More
Vol-1 P-15 I-2.5.2 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. ---- Work Should be carried out at the site as per the direction of Engineer incharge

7.98

6843

54607.14

... More
Vol-1 P-112 I-15 - Formwork,Centring & Scaffolding 50% for Roof Slab ---- Work Should be carried out at the site as per the direction of Engineer incharge

7.98

3421

27303.57

... More
Vol-1 P-18 I-2.11a - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- Work Should be carried out at the site as per the direction of Engineer incharge

0.22

89457

19680.54

... More
Vol-2 P-6.8 I-14 - Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. ---- Work Should be carried out at the site as per the direction of Engineer incharge

12.32

7969

98178.08

... More
Vol-2 P-41 I-8.1.1 - Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out at the site as per the direction of Engineer incharge

49.98

255

12744.9

... More
Vol-2 P-42 I-8.9 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- Work Should be carried out at the site as per the direction of Engineer incharge

49.98

385

19242.3

... More
Vol-2 P-26 I-7.38 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.. ---- Work Should be carried out at the site as per the direction of Engineer incharge

27.52

568

15631.36

... More
VOL-6 1.2.2 - 2 of 105 - Concealed Conduit System :Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary25mm dia 2mm thick. ---- Work Should be carried out at the site as per the direction of Engineer incharge

20

78

1560

... More
VOL-6 1.3.2 - 5 of 105 - Supplying heavy gauge PVC Conduit Pipe 25dia 2mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thick. ---- Work Should be carried out at the site as per the direction of Engineer incharge

100

79

7900

... More
VOL-6 2.3.3 - 5 of 105 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,2.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS694:1990 & confirming to GTP. ---- Work Should be carried out at the site as per the direction of Engineer incharge

260

42

10920

... More
VOL-6 2.3.2 - 5 of 105 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,1.5 SQMM multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP. ---- Work Should be carried out at the site as per the direction of Engineer incharge

100

26

2600

... More
VOL-6 3.5.2 - 8 of 105 - Supplying and fixing superior quality 3Mudular modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal box. ---- Work Should be carried out at the site as per the direction of Engineer incharge

20

161

3220

... More
VOL-6 3.5.5 - 8 of 105 - Supplying and fixing superior quality 8 modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalbox. ---- Work Should be carried out at the site as per the direction of Engineer incharge

10

284

2840

... More
VOL-6 13.10 - 57 of 105 - Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired ---- Work Should be carried out at the site as per the direction of Engineer incharge

15

171

2565

... More
VOL-6 8.8 - 36 - Supplying & Fixing of Fan 8.8/36 ---- Work Should be carried out at the site as per the direction of Engineer incharge

15

1209

18135

... More
VOL-6 3.14.6 - 10 of 105 - Supplying and fixing of 6AmpsLamp holder on existing board. ---- Work Should be carried out at the site as per the direction of Engineer incharge

15

71

1065

... More
VOL-6 11.11.4 - 45 of 105 - Supplying & fixing of retrofit type-LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500degree K,CRI 70 .efficacy 80 lumenper W, life 25000 burning hours and Compliance to IS10322 / IEC 60598,LM79&LM80.The LED are driven by HF electronic driver integrated in the system, withPF 0.95, power loss should 5%oflampWage. ,shortcircuit& opencircuitprotectiontobeintegratedinthecircuit,THDlessthan20%,LifeasperLM79.Theoperatinginputvoltageshouldbebetween130to275V.BISApprovedandTestedbyNABL/CPRIaccreditedlaboratorywith2yearsWarrantyagainstanymanufacturing defect working under standard electrical condition. ---- Work Should be carried out at the site as per the direction of Engineer incharge

25

154

3850

... More
VOL-5 PG-191 It-16.10 - Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- Work Should be carried out at the site as per the direction of Engineer incharge

5

4236

21180

... More
VOL-5 PG-113 IT-10.1.7 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- Work Should be carried out at the site as per the direction of Engineer incharge

45

411

18495

... More
Vol-2 P-125 I-13.48 - Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameterPipes ---- Work Should be carried out at the site as per the direction of Engineer incharge

20

291

5820

... More
Vol-2 P-64 I-9.36 - Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. . ---- Work Should be carried out at the site as per the direction of Engineer incharge

223.41

1650

368626.5

... More
Vol-2 P-61 I-9.17.1 - Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 500x500 mm. ---- Work Should be carried out at the site as per the direction of Engineer incharge

204.09

1112

226948.08

... More
Vol-2 P-71 I-10.14 - Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete. (CSR 23-24 vol 2, pg no 71 and item no 10.14) ---- Work Should be carried out at the site as per the direction of Engineer incharge

107.82

1106

119248.92

... More
Vol-2 P-60 I-9.10 - Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete. (CSR 23-24 vol 2, pg no 60 and item no 9.10) ---- Work Should be carried out at the site as per the direction of Engineer incharge

15.84

1106

17519.04

... More
Vol-2 P-65 I-9.39 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.(CSR 23-24 vol 2, pg no 65 and item no 9.38) ---- Work Should be carried out at the site as per the direction of Engineer incharge

29.68

1449

43006.32

... More
Vol-2 P-119 I-13.12 - Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 (CSR 23-24 vol 2, pg no 119 and item no 13.12) ---- Work Should be carried out at the site as per the direction of Engineer incharge

30

635

19050

... More
Vol-2 P-137 I-14.40.2 - Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. (CSR 23-24 vol 2, pg no 137 and item no 14.40) ---- Work Should be carried out at the site as per the direction of Engineer incharge

10

496

4960

... More
Vol-2 P-122 I-13.31.3 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes (CSR 23-24 vol 2, pg no 122 and item no 13.31.3) ---- Work Should be carried out at the site as per the direction of Engineer incharge

40

318

12720

... More
Vol-2 P-127 I-13.59 - Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete (CSR 23-24 vol 2, pg no 117 and item no 13.2.2) ---- Work Should be carried out at the site as per the direction of Engineer incharge

20

220

4400

... More
Vol-2 P-86 I-11.34A - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (CSR 23-24 vol 2, pg no 86 and item no 11.34A) ---- Work Should be carried out at the site as per the direction of Engineer incharge

2891.89

168

485837.52

... More
Vol-1 P-15 I-2.1.4 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (CSR 23-24 vol 1, pg no 15 and item no 2.1.4 ---- Work Should be carried out at the site as per the direction of Engineer incharge

14.66

6217

91141.22

... More
Vol-2 P-131 I-14.1.1 - Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests .(CSR 23-24 vol 2, pg no 131 and item no 14.1.1) ---- Work Should be carried out at the site as per the direction of Engineer incharge

6

4884

29304

... More
Vol-2 P-133 I-14.10.1.1 - Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required 510x1040 mm bowl depth 250 mm (CSR 23-24 vol 2, pg no 133 and item no 14.10.1.1) ---- Work Should be carried out at the site as per the direction of Engineer incharge

1

5618

5618

... More
Vol-2 P-69 I-10.1.2 - Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give highm gloss finish etc. complete at all levels.Area of slab over 0.50 m2 (CSR 23-24 vol 2, pg no 69 and item no 10.1.2) ---- Work Should be carried out at the site as per the direction of Engineer incharge

2.7

3937

10629.9

... More
Vol-2 P-45 I-8.25 - Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and includin water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (CSR 23-24 vol 2, pg no 45 and item no 8.25) ---- Work Should be carried out at the site as per the direction of Engineer incharge

1217.57

137

166807.09

... More
Vol-2 P-45 I-8.28 - Finishing walls with water proofing cement paint of required shade : New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(CSR 23-24 vol 2, pg no 45 and item no 8.28) ---- Work Should be carried out at the site as per the direction of Engineer incharge

743.12

89

66137.68

... More
VOL-6 5.19.9 - 18 of 105 - Supplying and fixing 12way regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.I - doble Door12way sp&n.(PWD Electrical SR-II 2023-24)5.19.9 / (18 of 105) ---- Work Should be carried out at the site as per the direction of Engineer incharge

2

2329

4658

... More
VOL-6 3.6.9 - 9 of 105 - Supplying and fixing of32Amps modular DP Switch on existing modular switch plate as per IS 3854 and IS 1293.(PWD Electrical SR-II 2023-24)3.6.9 / (9 of 105) ---- Work Should be carried out at the site as per the direction of Engineer incharge

4

326

1304



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.