Public Works Department Tender

... More
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Public Works Department - PWD Tender

Works
Electrical and Electronics
Electrical Works
Opening Date6 Mar 2025
Closing Soon17 Mar 2025
Tender Amount₹ 17,79,013.15 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

  • Tender Id

    PWD/2024-25/EL/WORK_INDENT19484
  • Tender No

    PWD/2024-25/EL/WORK_INDENT19484
  • Tender Authority

    Public Works Department View
  • Purchaser Address

    -
Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Vol-6 Chapter-3 It No.3.14.3 Pg.No. 10 of 105 - Supplying and fixing replacing of 6 16 32Amps electrical accessories on existing switch board. 6Amps Three Way 5pin Socket

50

73

3675

... More
Vol-6 Chapter-3 It No.3.14.4 Pg.No. 10 of 105 - Supplying and fixing replacing of 6 16 32Amps electrical accessories on existing switch board. 6Amps Three Pin Top

25

91

2283.75

... More
Vol-6 Chapter-3 It No.3.14.5 Pg.No. 10 of 105 - Supplying and fixing replacing of 6 16 32Amps electrical accessories on existing switch board. 6Amps Bakelite Ceiling Rose

35

81

2866.5

... More
Vol-6 Chapter-3 It No.3.14.7 Pg.No. 10 of 105 - Supplying and fixing replacing of 6 16 32Amps electrical accessories on existing switch board. 6Amps Batten Holder

75

77

5827.5

... More
Vol-6 Chapter-3 It No.3.14.8 Pg.No. 10 of 105 - Supplying and fixing replacing of 6 16 32Amps electrical accessories on existing switch board. 6Amps Bell Push

12

73

882

... More
Vol-6 Chapter-3 It No.3.14.10 Pg.No. 10 of 105 - Supplying and fixing replacing of 6 16 32Amps electrical accessories on existing switch board. 16A SP Switch

16

137

2200.8

... More
Vol-6 Chapter-3 It No.3.14.12 Pg.No. 10 of 105 - Supplying and fixing replacing of 6 16 32Amps electrical accessories on existing switch board. 16Amps Three Way 5 pin Socket

16

120

1932

... More
Vol-6 Chapter-3 It No.3.14.13 Pg.No. 10 of 105 - Supplying and fixing replacing of 6 16 32Amps electrical accessories on existing switch board. 16Amps Three Pin Top

13

115

1501.5

... More
Vol-6 Chapter-3 It No.3.14.16 Pg.No. 10 of 105 - Supplying and fixing replacing of 6 16 32Amps electrical accessories on existing switch board. Electronic Stepped Regulator

45

295

13277.25

... More
Vol-6 Chapter-2 It No.2.1.1 Pg.No. 5 of 105 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch

7

299

2094.75

... More
Vol-6 Chapter-2 It No.2.1.2 Pg.No. 5 of 105 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch

6

413

2482.2

... More
Vol-6 Chapter-2 It No.2.1.3 Pg.No. 5 of 105 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch

4

598

2394

... More
Vol-6 Chapter-12 It No.12.3.2 Pg.No.48 of 105 - Supplying and fixing replacing condenser for ceiling fan MV SV MH and other luminaries. 8mfd

70

171

11980.5

... More
Vol-6 Chapter-12 It No.12.4.3 Pg.No.48 of 105 - Rewinding a 1200mm ceiling fan after using necessary gauge annealed and insulated copper wire with necessary insulating, separators vibration arresting shellac, etc including replacement of bearings if any transportation to and from the spot to workshop inclusive of releasing the refixing.

35

803

28113.75

... More
Vol-6 Chapter-12 It No.12.6 Pg.No.48 of 105 - Supplying and replacing ceiling fan regulator 900mm to 1500mm.

20

406

8127

... More
Vol-6 Chapter-12 It No.12.8 Pg.No.48 of 105 - Releasing the existing fan checking, testing and installation at the same place.

35

36

1286.25

... More
Vol-6 Chapter-12 It No.12.9 Pg.No.48 of 105 - Releasing the existing fan checking, testing and installation at the New place.

10

75

756

... More
Vol-6 Chapter-12 It No.12.10 Pg.No.48 of 105 - Releasing the existing fan and refixing the same in the new place with clamps without S’ hook complete.

10

84

840

... More
Vol-6 Chapter-12 It No.12.11 Pg.No.48 of 105 - Releasing the existing FTL Fitting all capacities, checking, testing and installing at same place.

70

39

2793

... More
Vol-6 Chapter-12 It No.12.12.1 Pg.No.48 of 105 - Supplying and fixing replacing of fluorescent tube. 18 to 40Watts

60

99

5985

... More
Vol-6 Chapter-12 It No.12.13.1 Pg.No.49 of 105 - Supplying and fixing replacement of heating element for Geyser Boiler. 2KW Capacity

16

1101

17623.2

... More
Vol-6 Chapter-12 It No.12.13.1 Pg.No.49 of 105 - Supplying and fixing replacement of heating element for Geyser Boiler. 3KW Capacity

16

1174

18799.2

... More
Vol-6 Chapter-12 It No.12.14 Pg.No.49 of 105 - Supplying and fixing replacement of pressure relief valve suitable for Geyser.

10

651

6510

... More
Vol-6 Chapter-12 It No.12.23 Pg.No.50 of 105 - Supplying and fixing 20 40 Watts heavy duty open construction ferromagnetic copper ballast for fluorescent tubes: 65 80 Watts heavy duty open construction Ferromagnetic copper ballast for fluorescent tubes, Class H Insulated copper wire, Vacuum impregnated high quality with Low loss silicon steel lamination operated on 240V,50Hz supply with IEC 60920 (Safety) & IEC 60921(Performance). Operating voltage range from 180V to 265V, 50Hz AC power Supply.

18

307

5537.7

... More
Vol-6 Chapter-12 It No.12.44 Pg.No.52 of 105 - Supplying & Fixing of 230 Volts 20 40 watts starter for Fluorescent Lamp

90

31

2835

... More
Vol-6 Chapter-12 It No.12.45 Pg.No.52 of 105 - Supplying & Fixing of 230 Volts 20 40 watts Fluorescent Lamp holder

70

34

2425.5

... More
Vol-6 Chapter-12 It No.12.46 Pg.No.52 of 105 - Supplying & Fixing of 70-150 Watts lamp holder 2 Pin

65

66

4299.75

... More
Vol-6 Chapter-12 It No.12.25.2 Pg.No.50 of 105 - Supplying of patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired with HF Electronic Ballast, Operating voltage range from 180V to 265V, 50Hz AC power supply excluding Tube.1 x 4' Tube light fitting.

15

357

5355

... More
Vol-6 Chapter-2 It No.2.3.1 Pg.No. 5 of 105 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:2010 1 sqmm.

265

19

5286.75

... More
Vol-6 Chapter-2 It No.2.3.2 Pg.No. 5 of 105 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:2010 1.5sqmm.

385

27

10510.5

... More
Vol-6 Chapter-2 It No.2.3.3 Pg.No. 5 of 105 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:2010 2.5sqmm.

170

44

7497

... More
Vol-6 Chapter-2 It No.2.3.4 Pg.No. 5 of 105 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:2010 4sqmm.

145

66

9591.75

... More
Vol-6 Chapter-5 It No.5.18.1 Pg.No.17 of 105 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP

25

435

10893.75

... More
Vol-6 Chapter-5 It No.5.18.4 Pg.No.17 of 105 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps DP

10

775

7759.5

... More
Vol-6 Chapter-5 It No.5.18.9 Pg.No.18 of 105 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63Amps TPN

2

3242

6484.8

... More
Vol-6 Chapter-11 It No.11.11.6 Pg.No.47 of 105 - Supplying & fixing of retrofit type - LED bulb 15W 6500K with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should Lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.

22

342

7530.6

... More
Vol-6 Chapter-11 It No.11.11.7 Pg.No.47 of 105 - Supplying & fixing of retrofit type - LED bulb 18W 6500K with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should Lesser than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.

15

447

6709.5

... More
Vol-6 Chapter-11 It No.11.3.2 Pg.No.42 of 105 - Supplying of LED Light fighting 1 x 4'feet - PVC Batten with integrated LED tube 20 22W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50 60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.

18

724

13041

... More
Vol-6 Chapter-13 It No.13.7.1 Pg.No.56 of 105 - Fixing all types and all capacities of fluorescent false ceiling spot light CFL LED fittings indoor on the wall ceiling rafters girders using 23 0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall ceiling Rafter Girders

18

128

2305.8

... More
Vol-6 Chapter-12 It No.12.56 Pg.No.54 of 105 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia

7

3685

25798.5



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.