Public Works Department Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Public Works Department - PWD Tender

Electrical Goods and Equipments
Electrical and Electronics
Opening Date30 Sep 2024
Closing Date14 Oct 2024
Tender Amount₹ 24,46,424.4 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
UNI SR-2022-23 PWD Elec VOL-VI Part-I I.No.5.20.4, - Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240 450V up to 300mA sensitivity on existing wood panel board. - 63 Amps 4 pole

1

3210

3210.9

... More
UNI SR-2023-24 PWD Elec VOL-VI Part-I I.No.5.11.4 - Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. - 200Amps

1

13891

13891.5

... More
UNI SR-2023-24 PWD Elec VOL-VI Part-I I.No.5.8.5 - Supplying of Switch disconnector fuse unit (TPN) HRC type (but without HRC fuses). With AC-23A duty and as per IS-13947. - 200Amps

1

8910

8910.3

... More
Distribution(ESCOMs) SL.No. 211 I.No. 32.15 Materi - Supplying of 1.1 KV LT UG cable having aluminum conductor PVC insulated, extruded inner sheathed, galvanized, steel strips (except 2CX10Sq.mm wire armoured) as per IS-3975:1990 & extruded PVC outer sheathed armoured cable as per IS-1554 Part-1:1988 & confirming to GTP of GROUP-B - 3.5 core 120 sqmm

0.08

479733

38378.676

... More
ESCOMs Labour SL.No. 169 I.No. 20.07 Pg. No. 52 - Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe stoneware pipe on wall on pole as required.In existing trench duct. - 120sqmm to 240Sqmm

0.08

2838

227.052

... More
VOL-VI Part-II (ESCOMs) Labour I.No. 29.03 Pg. 63 - Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) - In soil (hard)

7.5

408

3063.375

... More
VOL-VI Part-II (ESCOMs) Labour I.No. 29.03 Pg. 63 - Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable

7.5

60

456.75

... More
VOL-VI Part-II (ESCOMs) SL.No. 49 I.No. 48.09 Mate - Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole wall drain crossing with necessary clamping arrangements for UG cable of 1.1 KV. - 100mm

5

1360

6804

... More
VOL-VI Part-II SL.No. 463 I.No. 59.07 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. - 150 sqmm Long Barrel

5

192

960.75

... More
DSR-2019-20 PWD Elec I.No.6.3.9, Pg. No. 40 - Supplying and running of GI Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper strip - 50x6mm

3

2042

6126.75

... More
VOL-VI Part-I I.No.5.19.14 , Pg. No.18 of 105 - Supplying and fixing regular MCB distribution boards on wall wood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase 3 phase single door with powder coated painting. Made out of 14 SWG MS enclosure.I - Single Door - 12Way TP &N

1

9171

9171.75

... More
UNI SR-2023-24 PWD Elec VOL-VI Part-III It.No.12.5 - Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts

3

4468

13406.4

... More
2023-24 PWD Vol-1 It.No.1.5.1 Pg.No.6 of 214 - Earth work excavation for foundation of buildings water supply sanitary lines and electrical conduits either in pits or in trenches 1.5 m and above in width, in hard soil not exceeding 1.5 m depth including dressing the bottom and sides of pits and trenches stacking the excavated soil clear from edges of excavation with lead up to 50 m after breaking of clods complete as per specification

15

313

4709.25

... More
2023-24 PWD Vol-1 It.No.2.1.5 Pg.No.15 of 214 - Providing and laying in position plain cement of mix M 15 with OPC cement @ 240 kgs , with 40mm and down size graded granite metal coarse aggregates @ .8787 cum an fine aggregates @ .459 cum machine mixed , concrete laid in layers not exceeding 15cms thick, well compacted, in foundation and plinth, including cost of all materials, labour, HOM of machinery, curing complete as per specifications

4.5

6463

29087.1

... More
2023-24 PWD Vol-1 It.No.2.2.1 Pg.No.15 of 214 - KSRB 4-1.1 : Providing and laying in position plain cement of mix M 20 with OPC cement @ 300 kgs , with 20mm and down size graded granite metal coarse aggregates @ .64 cum an fine aggregates @ .43 cum with super plaster @ 3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed , concrete laid in layers not exceeding 15cms thick, well compacted, in foundation and plinth and cills, including cost of all materials, labour, HOM of machinery, curing complete as per specs

10.72

6601

70766.472

... More
2023-24 PWD Vol-1 It.No.2.11.b Pg.No.18 of 214 - Providing mild steel reinforcement for R.C.C work including straightening. Cutting, bending, hooking placing in position, lapping and or welding wherever required, tying with binding wire and anchoring to the adjoining member wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid ) cost of materials, labour HOM of machinery complete as per specification

0.2

93929

18785.97

... More
VOL-VI Part-III I.No.1.1.2 , Pg. No.02 of 105 - Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia .mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. - 25mm dia 2mm thick

200

85

17010

... More
VOL-VI Part-III I.No.2.2.1, Pg. No.05 of 105 - Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. GROUP A - Short point upto 3Mtr from tapping point to out let via switch

5

282

1412.25

... More
VOL-VI Part-III I.No.2.2.2 , Pg. No.05 of 105 - Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. GROUP A - Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches

8

397

3183.6

... More
VOL-VI Part-III I.No.22.3, Pg. No.05 of 105 - Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. GROUP A - Long point above 6Mtr upto 10Mtr from tapping point to out let via switch

10

582

5827.5

... More
VOL-VI Part-III I.No.2.3.2 , Pg. No.05 of 105 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. - 1.5 sqmm

200

27

5460

... More
VOL-VI Part-III I.No.2.3.3, Pg. No.05 of 105 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. - 2.5 sqmm

400

44

17640

... More
VOL-VI Part-III I.No.2.3.4, Pg. No.05 of 105 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. - 4 sqmm

100

66

6615

... More
VOL-VI Part-III I.No.6.2.2, Pg. No.30 of 105 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. - 15" Sweep (450mm)

1

4668

4668.3

... More
VOL-VI Part-III I.No.13.14, Pg. No.57 of 105 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23 0.0076 inch PVC insulated twin core wire.

1

516

516.6

... More
VOL-VI Part-III I.No.11.3.2, Pg. No.43 of 105 - Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50 60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. - LED light fitting 1 x4'- 20 22 w

15

724

10867.5

... More
VOL-VI Part-III I.No.13.7.1, Pg. No.56 of 105 - Fixing all types and all capacities of fluorescent false ceiling spot light CFL LED fittings indoor on the wall ceiling rafters girders using 23 0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.

15

128

1921.5

... More
VOL-VI Part-III I.No.11.8.2, Pg. No.46 of 105 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage Overload, short circuit miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50 60Hz application. Compliance to IS 10322 IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency greater than130lm w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree Nichia Lumileds Osram make LED Source. - LED Streetlight 40watts

10

4225

42252

... More
VOL-VI Part-III I.No.13.5, Pg. No.56 of 105 - Fixing halogen metal halide SVL IL LED floodlight fitting over existing pole wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.

10

170

1701

... More
VOL-VI Part-III I.No.3.3.5, Pg. No.8 of 105 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall - 8 Way

8

229

1839.6

... More
VOL-VI Part-III I.No.3.5.5, Pg. No.8 of 105 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal PVC box. - 8 Modules

8

298

2385.6

... More
PWD Elec VOL-VI Part-III I.No.3.6.1, Pg. No.9 of 1 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6Amps one way Switch

40

107

4284

... More
VOL-VI Part-III I.No.3.6.10, Pg. No.9 of 105 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6 16Amps universal socket

10

247

2478

... More
Lumpsum - LS for GESCOM Deposits , Electrical Inspectorate Charges and Other Miscelenous Items

1

404500

404500



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.