Public Works Department Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 25,000Document Cost
Refer DocumentsTender Fee
₹ 620
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
PWD/2024-25/EL/WORK_INDENT15656Bid Award Id
ViewTender No
PWD/2024-25/EL/WORK_INDENT15656Tender Authority
Public Works Department ViewPurchaser Address
-
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
UNI SR-2022-23 PWD Elec VOL-VI Part-I I.No.5.20.4, - Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240 450V up to 300mA sensitivity on existing wood panel board. - 63 Amps 4 pole
1
3210
3210.9
UNI SR-2023-24 PWD Elec VOL-VI Part-I I.No.5.11.4 - Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. - 200Amps
1
13891
13891.5
UNI SR-2023-24 PWD Elec VOL-VI Part-I I.No.5.8.5 - Supplying of Switch disconnector fuse unit (TPN) HRC type (but without HRC fuses). With AC-23A duty and as per IS-13947. - 200Amps
1
8910
8910.3
Distribution(ESCOMs) SL.No. 211 I.No. 32.15 Materi - Supplying of 1.1 KV LT UG cable having aluminum conductor PVC insulated, extruded inner sheathed, galvanized, steel strips (except 2CX10Sq.mm wire armoured) as per IS-3975:1990 & extruded PVC outer sheathed armoured cable as per IS-1554 Part-1:1988 & confirming to GTP of GROUP-B - 3.5 core 120 sqmm
0.08
479733
38378.676
ESCOMs Labour SL.No. 169 I.No. 20.07 Pg. No. 52 - Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe stoneware pipe on wall on pole as required.In existing trench duct. - 120sqmm to 240Sqmm
0.08
2838
227.052
VOL-VI Part-II (ESCOMs) Labour I.No. 29.03 Pg. 63 - Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) - In soil (hard)
7.5
408
3063.375
VOL-VI Part-II (ESCOMs) Labour I.No. 29.03 Pg. 63 - Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable
7.5
60
456.75
VOL-VI Part-II (ESCOMs) SL.No. 49 I.No. 48.09 Mate - Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole wall drain crossing with necessary clamping arrangements for UG cable of 1.1 KV. - 100mm
5
1360
6804
VOL-VI Part-II SL.No. 463 I.No. 59.07 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. - 150 sqmm Long Barrel
5
192
960.75
DSR-2019-20 PWD Elec I.No.6.3.9, Pg. No. 40 - Supplying and running of GI Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper strip - 50x6mm
3
2042
6126.75
VOL-VI Part-I I.No.5.19.14 , Pg. No.18 of 105 - Supplying and fixing regular MCB distribution boards on wall wood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase 3 phase single door with powder coated painting. Made out of 14 SWG MS enclosure.I - Single Door - 12Way TP &N
1
9171
9171.75
UNI SR-2023-24 PWD Elec VOL-VI Part-III It.No.12.5 - Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts
3
4468
13406.4
2023-24 PWD Vol-1 It.No.1.5.1 Pg.No.6 of 214 - Earth work excavation for foundation of buildings water supply sanitary lines and electrical conduits either in pits or in trenches 1.5 m and above in width, in hard soil not exceeding 1.5 m depth including dressing the bottom and sides of pits and trenches stacking the excavated soil clear from edges of excavation with lead up to 50 m after breaking of clods complete as per specification
15
313
4709.25
2023-24 PWD Vol-1 It.No.2.1.5 Pg.No.15 of 214 - Providing and laying in position plain cement of mix M 15 with OPC cement @ 240 kgs , with 40mm and down size graded granite metal coarse aggregates @ .8787 cum an fine aggregates @ .459 cum machine mixed , concrete laid in layers not exceeding 15cms thick, well compacted, in foundation and plinth, including cost of all materials, labour, HOM of machinery, curing complete as per specifications
4.5
6463
29087.1
2023-24 PWD Vol-1 It.No.2.2.1 Pg.No.15 of 214 - KSRB 4-1.1 : Providing and laying in position plain cement of mix M 20 with OPC cement @ 300 kgs , with 20mm and down size graded granite metal coarse aggregates @ .64 cum an fine aggregates @ .43 cum with super plaster @ 3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed , concrete laid in layers not exceeding 15cms thick, well compacted, in foundation and plinth and cills, including cost of all materials, labour, HOM of machinery, curing complete as per specs
10.72
6601
70766.472
2023-24 PWD Vol-1 It.No.2.11.b Pg.No.18 of 214 - Providing mild steel reinforcement for R.C.C work including straightening. Cutting, bending, hooking placing in position, lapping and or welding wherever required, tying with binding wire and anchoring to the adjoining member wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid ) cost of materials, labour HOM of machinery complete as per specification
0.2
93929
18785.97
VOL-VI Part-III I.No.1.1.2 , Pg. No.02 of 105 - Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia .mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. - 25mm dia 2mm thick
200
85
17010
VOL-VI Part-III I.No.2.2.1, Pg. No.05 of 105 - Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. GROUP A - Short point upto 3Mtr from tapping point to out let via switch
5
282
1412.25
VOL-VI Part-III I.No.2.2.2 , Pg. No.05 of 105 - Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. GROUP A - Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches
8
397
3183.6
VOL-VI Part-III I.No.22.3, Pg. No.05 of 105 - Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. GROUP A - Long point above 6Mtr upto 10Mtr from tapping point to out let via switch
10
582
5827.5
VOL-VI Part-III I.No.2.3.2 , Pg. No.05 of 105 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. - 1.5 sqmm
200
27
5460
VOL-VI Part-III I.No.2.3.3, Pg. No.05 of 105 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. - 2.5 sqmm
400
44
17640
VOL-VI Part-III I.No.2.3.4, Pg. No.05 of 105 - Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. - 4 sqmm
100
66
6615
VOL-VI Part-III I.No.6.2.2, Pg. No.30 of 105 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. - 15" Sweep (450mm)
1
4668
4668.3
VOL-VI Part-III I.No.13.14, Pg. No.57 of 105 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23 0.0076 inch PVC insulated twin core wire.
1
516
516.6
VOL-VI Part-III I.No.11.3.2, Pg. No.43 of 105 - Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50 60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. - LED light fitting 1 x4'- 20 22 w
15
724
10867.5
VOL-VI Part-III I.No.13.7.1, Pg. No.56 of 105 - Fixing all types and all capacities of fluorescent false ceiling spot light CFL LED fittings indoor on the wall ceiling rafters girders using 23 0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.
15
128
1921.5
VOL-VI Part-III I.No.11.8.2, Pg. No.46 of 105 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage Overload, short circuit miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50 60Hz application. Compliance to IS 10322 IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency greater than130lm w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree Nichia Lumileds Osram make LED Source. - LED Streetlight 40watts
10
4225
42252
VOL-VI Part-III I.No.13.5, Pg. No.56 of 105 - Fixing halogen metal halide SVL IL LED floodlight fitting over existing pole wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
10
170
1701
VOL-VI Part-III I.No.3.3.5, Pg. No.8 of 105 - Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall - 8 Way
8
229
1839.6
VOL-VI Part-III I.No.3.5.5, Pg. No.8 of 105 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal PVC box. - 8 Modules
8
298
2385.6
PWD Elec VOL-VI Part-III I.No.3.6.1, Pg. No.9 of 1 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6Amps one way Switch
40
107
4284
VOL-VI Part-III I.No.3.6.10, Pg. No.9 of 105 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6 16Amps universal socket
10
247
2478
Lumpsum - LS for GESCOM Deposits , Electrical Inspectorate Charges and Other Miscelenous Items
1
404500
404500