National Power Training Institute Tender
Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
National Power Training Institute - NPTI Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date13 Feb 2023
Closing Date23 Feb 2023
Tender AmountRefer Documents
Costs
EMD
₹ 1,00,000Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_NPTI_740320_1Tender No
NPTI/HQ/AMI/2022-23/3533Tender Authority
National Power Training Institute ViewPurchaser Address
-Website
http://https://npti.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Server for Utility's Application Software such as Billing System Software/ SCADA/ R-APDRP/GIS/ERP/Web Portal etc.
Processor Cores: 6
Processor Cache: 11.00 MB L3
Processor Name: Intel® Xeon® Scalable 3204 (6 core, 1.9 GHz, 85W)
Processor Number: 1
Processor Speed: 1.9 GHz
Memory Type: DDR4
Standard Memory: 8 GB (1x 8 GB) RDIMM
Hard Drive: 1 TB
Power Supply: 350W or better or as per OEM
Expansion Slots: 5 PCIe 3.0
Network Controller: 1Gb 2-port
Storage Controller: RAID1
Form Factor: Tower
1
-
-
Head End System Software
The HES software shall be capable of performing the primary tasks between smart meter/ DCU and HES such as Automatic polling / On Demand reads, Two way communication establishment, Remote Disconnect / Reconnect, Data encryption for communication, RTC time synchronization, Data retention, Control signals / Event messages handling & logging, Smart meter configuration support, Communication device status and history logging, Network information logging, and Critical and non-critical reporting etc.
1
-
-
MDM Software
The MDM software shall be capable of performing the primary tasks between HES and MDM as well as MDM and Other Applications of DISCOMs such as Meter asset management, Meter installation support, Meter data management, Data Validation, Estimation, and Editing (VEE), Billing determinants calculations, Exception management, Service order management, Customer service support, Data analysis & reporting, Revenue protection support, Demand control / Demand Response Support, Prepayment functionality, Net metering integration, Other business system integrations etc.
1
-
-
Interface Evaluation Software between Utility's Software Applications and MDMS
As the MDMS is developed the AMI Solution provider, interface software is required for the seamless data exchange between the utility’s existing IT and software infrastructure. The interface evaluation software should be capable of designing the interface between MDM software and the existing Utility’s software applications such as Billing System Software/ SCADA/ R-APDRP/GIS/ERP/Web Portal etc. As this AMI lab is aimed to train the Power Utilities all over India, the offered Interface evaluation software should be capable of designing interfaces for applications of all Power Utilities in India.
1
-
-
Prepaid Recharge System Simulator
This simulator shall be used for recharging the smart prepaid meters.** It should be Pre-paid facility perform by Generalised System.
1
-
-
In-Home Display
The In-Home Display shall be connected to the smart meter wirelessly and the show the essential information of the meter display and alerts to the consumers. The IHD shall be provided with RF and RS-232 communication ports.
2
-
-
Data Concentrator Unit
The data concentrator unit (DCU) shall collect the information from Smart meters and update to the HES. Also, DCU shall receive commands or updates from HES and send to the smart metes. DCU shall work with RF/ 4G/5G Communication. The No. of meters need to be connected to each DCU is 20 ( 10 Nos single phase and 10 Nos 3 phase)
Expansion upto 100 meters shall be considered. ii) The No. of Data points, event records shall be stored as per relevant standards of REC documents.
iii) Data retention period for cyclic recording etc. (As per REC standard documents)
2
-
-
Router
A router with 1xWAN port, 1xLTE LAN, 4xLAN, 1xRS232 port, and 1xUSB port shall be provided. The WAN port shall be connected to lease line provided by NPTI. The router shall work in redundant communication mode with auto failover to LTE network in case leased line is down. When lease line resumes, the router shall change the communication to lease line from LTE network seamlessly. The RS-232 port shall be capable of sending SMS alerts without interrupting the Data connection.
1
-
-
GPS Clock for laboratory
A satellite GPS clock system shall be provided for synchronizing the Real-time for entire AMI network.
1
-
-
3-ph Power source (variable test panel) 3-Ph 415V, 15A Panel with Resistive Dummy Load
Input Voltage: 3x240V, +20% 3 phase 4 wire, Input frequency: 50Hz +/- 5%, Input Switch: 3 pole MCB of adequate rating, Output Voltage: 3x300V (Adjustable from Zero Volts), Output Current: Adjustable from zero to 15AMPS, Output Burden on: 15VA on each phase Current Circuit, Power Factor select through UPF, LAG LEAD, Isolation between input and output voltages, Isolation between output voltage and output current, Equipment will be rated for continuous operation.
1
-
-
DC - Electromagnet
Magnetic field 67 MT& 02.T DC+5%Ampere turns 1000AT& 17500AT,Electro Magnetic size as per CBIP TR 88, CLAUSE.5.6.2.1 Including Dc Voltage Source.
2
-
-
AC - Electromagnet
AC Electro magnet 00.5mill Tesla & 10 mill Tesla AC +/-5%, 2800 AT for 10millTesla AC Electromagnet. & 140 AT for 0.5 mill Tesla AC Electromagnet. The Electromagnet wound with supper enameled conductor. As per IS 13779.
2
-
-
Closed Type Dimmer stat
Closed type dimmer start Input:0-240V , AC, 50HZ; Output: 0-270V,AC 50 HZ 10 AMPS; Input supply: 3core mains cable; Output: Terminal: BTI Terminals.
2
-
-
Gauss Meter
Rangers full-scale: 0 to 2 and 0 to 20 Kilo Gauss; Accuracy : ±1%full scale + one digit on the 2K.Gass range;: ±2%full scale + one digit on the 20K.Gass range; Resolution : 0.1%of full scale. Visual Display : 3½ Digit panel meter, Power : 240 V a.c. 50 Hz., 10 Watts; Size & Weight: 210 mm x 95 mm x 225 mm and 1 Kg appr.
2
-
-
LED TV 70'' with ancillary support connection and support hangers
1
-
-
Storage & Backup Devices
-
-
-
External RAID Mass storage device ( for 24 months online backup)
1
-
-
Exteranl DAT drive : External DAT drive capacity shall be 7TB raw.
1
-
-
Switches
-
-
-
Layer II switch (AMI/SCADA/DMS LAN): It shall be with 24 ports + 24 ports of speed 1Gbps (Managed)
2
-
-
Layer II switch ( Planning & Development system LAN): It shall be with 24 ports + 24 ports of speed 1Gbps (Managed)
2
-
-
Routers
-
-
-
Router for interfacing EXTERNAL SYSTEM
2
-
-
Security system (DMZ)
-
-
-
Web server with load balancing
2
-
-
Mail server
2
-
-
Router
2
-
-
Firewall & network IDS/IPS
2
-
-
UTM (Unified Threat Management ) System alongwith Next Generation Industrial Firewall where the DPI tool should be incorporated. - 01 number
1
-
-
Layer II switch & Multilyers security Switch
2
-
-
Other Active Devices
-
-
-
GPS Time synchronisation system (A satellite GPS clock system shall be provided for synchronizing the Real-time for entire AMI network. )
1
-
-
Time, day & date digital displays
1
-
-
RF Packet Sniffer Hardware
2
-
-
RF Protocol Analyzer Tool
1
-
-
DLMS/COSEM Protocol Validation Tool and protocol analyzer
1
-
-
Printers
-
-
-
Color inkjet printer with Ethernet networking, Automatic document feeder; Print from phone or tablet; Two-sided printing; Two-sided scanning; Scan to email; Scan to PDF; Fax; Front USB flash drive port; Optional high-capacity trays; Touchscreen; JetIntelligence cartridge- Print, copy, scan, fax(Canon/HP/Epson or Equivalent)
1
-
-
B/W Laser printer-Ethernet networking, Automatic document feeder; Print from phone or tablet; Two-sided printing; Two-sided scanning; Scan to email; Scan to PDF; Fax; Front USB flash drive port; Optional high-capacity trays; Touchscreen; JetIntelligence cartridge- Print, copy, scan, fax(Canon/HP/Epson or Equivalent)
2
-
-
GIS SERVER WITH SW : GIS shall be supplied for 100 meters and 50 Nos of other assets (assets are referred to the items of BoQ).
1
-
-
Ancillary Items
-
-
-
DC Regulated Power Supply
Input : 230V +10%, 50-60Hz, Single Phase, Mode at the Output : Constant Voltage Mode, Output Voltage: 0-30V DC, Output Current: 0-5A DC settable continuously with two potentio- meters provided on Front Panel clearly marked with coarse and fine controls.
1
-
-
Humidity and Temperature Sensor Display
Temperature Range : -50˚C ~70˚C (-58˚F ~ 158˚F), Temperature Accuracy : ±1.0˚C or ±1.8˚F, Humidity Range : 10% ~ 99% RH, Humidity Accuracy : ±5% (35% ~ 75%) & else ±10%, Time / Temperature / Humidity indicate, Temperature Reading for ˚F &˚C, MAX./MIN. Temperature & Humidity Memory, Calendar with Alarm Clock.
1
-
-
Digital Multi-meter (Calibrated)
DC Voltage : 600mV/ 6 / 60 / 600 / 1000V, Accuracy : ± (1.0% rdg + 4 dgt)
DC Current 600 / 6000 A / 60 / 600mA/ 6 / 20A Accuracy : ± (1.0% rdg + 2 dgt)
AC Voltage : 600mV / 6 / 60 / 600 / 750V, Accuracy : ± (1.0% rdg + 5 dgt)
AC Current : 600 / 6000 A / 60 / 600mA/ 6 / 20A, Accuracy : ± (1.5% rdg + 5 dgt)
1
-
-
Magnifying lamp
Supply voltage: 230V AC, Lens diameter: Phase 125mm, Lens option: Common and optical lens optional, Magnifications: X3, X5; Adjustable range: 1000mm; Features: Table-clamping, folding arm
1
-
-
Communication Network Implementation for Smart Meters RF/4G/5G or any other suitable communication system
1
-
-
Smart Meter-1 Phase as per TS alongwith Test Bench with complete wiring and integration
10
-
-
Smart Meter-3 Phase as per TS alongwith Test Bench with complete wiring and integration
10
-
-
Hi-POT Test for Smart Meter functinality with Testing Tool of Meter
1
-
-
Hi-POT Test for Smart Meter functinality with Testing Tool of Meter
1
-
-
3 Phase Inductive Load
1
-
-
Redundant UPS system: 15 kVA
1
-
-
5 KW Solar Power Plant with LED Load ( On and Off Grid) with Bus Enterprise Solution for data display- (approximate 24 LED Lights Load will be supplied by NPTI)
1
-
-
Distribution Transformer Monitoring System
1
-
-
Furniture and Support Strcutre: As per the supplier requirement.
1
-
-
Model of a prepaid Electric Vehicle Charging station at Dashboard. (shall be integrated with the system when it's available)
1
-
-
Any other items required to meet functional /Performance requirement as per AMI Lab
1
-
-
Annual Maintenance Cost ( 5 Years)
1
-
-
Evaluation Notes How It Works ?