Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Minor Irrigation Department Tender

Civil And Construction
Excavation
Opening Date4 Jul 2024
Closing Date15 Jul 2024
Tender Amount₹ 4,69,742.9 
Notes
Download

Costs

Summary

Drilling Of Bore Well And Providing Electrification Of Dandiganahalli Village Sy No 24 Ramanjinappa Late Narayanappa Land In Manchenahalli Hobli, Gowribidanur Taluk, Chikkaballapura Dist.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
page no 151 item no 10 - Sinking Borewell of 165mm dia clear using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF & above in all strata including over burden upto 20M. Fixing of casing pipes, collars & cap with necessary cutting, threading & swelding including transportation of rig & supporting vehicle, crew charges & cost of consumables etc. Complete including yield testing at the final depth with a minimum working of compressor for one hour (excluding cost of casing pipes, collars, cap etc. ) complete with all lead and lifts as per detailed specification and direction of engineer in charge. (100.00 to 150.00 m)

50

387

19350

... More
page no 151 item no 10 - Sinking Borewell of 165mm dia clear using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF & above in all strata including over burden upto 20M. Fixing of casing pipes, collars & cap with necessary cutting, threading & swelding including transportation of rig & supporting vehicle, crew charges & cost of consumables etc. Complete including yield testing at the final depth with a minimum working of compressor for one hour (excluding cost of casing pipes, collars, cap etc. ) complete with all lead and lifts as per detailed specification and direction of engineer in charge. (150.00 to 200.00 m)

50

449

22450

... More
page no 151 item no 10 - Sinking Borewell of 165mm dia clear using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF & above in all strata including over burden upto 20M. Fixing of casing pipes, collars & cap with necessary cutting, threading & swelding including transportation of rig & supporting vehicle, crew charges & cost of consumables etc. Complete including yield testing at the final depth with a minimum working of compressor for one hour (excluding cost of casing pipes, collars, cap etc. ) complete with all lead and lifts as per detailed specification and direction of engineer in charge. (200.00 to 250.00 )

50

527

26350

... More
page no 154 item no 32 - Supply of ISI mark 175mm nominal bore, plain end steel casing pipe grade of steel Fe 410, of wall thickness 5.4 mm thick confirming to IS 4270:2001 & latest amendments electric resistance welded steel tube material and confirming to IS 1387 / 1993 and manufactured by basic open heat electric or basic oxygen process in random length of 5 to 7 mts. Both ends threaded confirming to IS 554/1985, one end fixed with a socket confirming to IS 4270:2001 & the other end with screwed pipes. All pipes shall be reasonably free from defects. The tubes shall be reasonably straight should be with ISI marking,weighing 25.10 Kg/mtr. (inclusive of all taxes and duties) Prices included collar-medium duty. etc., complete with all lead and lifts, as per detailed specification and as directed by the Engineer-in-charge.

15

1933

28995

... More
SR VOL-v page no 154 - Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with allamendments complete with all lead and lifts as per detailed specification and direction of engineer in charge.

1

150

150

... More
page no 154 item no 34 - Providing and laying at site of work MS casing caps as per IS 1239 (partII) 1982 with all latest amendments if any for any dia. The thickness ofplate used for covering one end shall be 3mm (minimum). The dimensionsof caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with allamendments including cost of material and labour charges for fixing, ifany etc. complete with all lead and lifts and as directed by the Engineerin charge complete with all lead and lifts as per detailed specification and direction of engineer in charge.

4

164

656

... More
page no 161 item no 20.3 - Providing,supplying to work site, Submersible Pump Set of 150mm diasuitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl& Impeller with Low volt Motor as per specifications,as per necessaryammendments and instructions of engineer incharge of work. For 20 HP. (20.00 HP - 155 LPM @ 280 m = 20 STG Outlet Dia - 2.00” complete with all lead and lifts as per detailed specification and direction of engineer in charge.

1

70154

70154

... More
page no 162 item no 33 - Supply and delivery of galvanized mild steel tubes of 6mtr standard lengthheavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) 50 mm dia complete with all lead and lifts as per detailed specification and direction of engineer in charge.

30

3050

91500

... More
page no 66 item no 6.5 - Labour charges for laying and jointing GI pipes with earth work including fixing collars, elbows, tees, bends, gland cocks and other fittings with cuts and threads, white lead paints wherever necessary, conveying the materials from office to workspot and retuning the surplus materials from workspot to stores for: 50 mm dia 50mm dia. GI pipes & specials. complete with all lead and lifts as per detailed specification and direction of engineer in charge.

175

29

5075

... More
page no 4 item no 2.63 - Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694:2010. 3C x 4 mm complete with all lead and lifts as per detailed specification and direction of engineer in charge.

350

167

58450

... More
page no 162 item no 27.1 - Supply and delivery at site of brand new best make gate valve as per IS778/1984 with ISI Mark and as per its latest amendmentswith ISI mark 50mm dia complete with all lead and lifts as per detailed specification and direction of engineer in charge.

1

1250

1250

... More
page no 162 item no 28.1 - Supply and delivery at site of brand new best make non-return valve asper IS 778/1984 with ISI Mark and as per its latest amendments with ISI mark 50mm dia complete with all lead and lifts as per detailed specification and direction of engineer in charge.

1

1275

1275

... More
page no 162 item no 30.2 - Supply, installing,testing, and commissioning COMMON control anelconsisting of the following INCOMING:1 No set of Phase indicatinglamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No AnalogVoltmeter 1ni with Phase selector switch, Isolating switch OUTGOINGfor Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Startersuitable for respective HP 1 No. Electrcal Protection Like single Phasepreventor, under voltage over Volage, under current over current & dryrun protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta StarteP 6 to 15 HP pumps complete with all lead and lifts as per detailed specification and direction of engineer in charge.

1

16500

16500

... More
page no 163 item no 38 - Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. complete with all lead and lifts as per detailed specification and direction of engineer in charge. page no 163 item no 38

1

6150

6150

... More
page no 11 item no 5.9.2 - Supplying and fixing HRC fuse units base on existing switch / panel board (b) 32 to 63 A amps. complete with all lead and lifts as per detailed specification and direction of engineer in charge.

3

270

810

... More
Page No. 29 Sl No. 5.37 - Supplying fixing and wiring heavy duty low voltage capacitors confirming to IS 2834, 3 phase 400/440 volts grade, for power factor improvements of rotating machinery, cost per KVAR (b) group B. complete with all lead and lifts as per detailed specification and direction of engineer in charge.

2

432

864

... More
page no 164 item no 45 - Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit.The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipeto the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. complete with all lead and lifts as per detailed specification and direction of engineer in charge.

1

3750

3750

... More
page no178 - Supply and laying of LG UT cable having aluminium conductor PVC insulated, sheathed, galvanized steel wire / steel tap armored cable with PVC over sheathing. complete with all lead and lifts as per detailed specification and direction of engineer in charge.

15

80

1200

... More
page No. 48 SL No. 6.5.1 - Labour charges for laying 1.1KV class UG when supplied agency in existing trench GI pipe / stonewate pipe / on wall / on poles as required in exising trench duct 6 sqmm to 16 sqmm complete with all lead and lifts as per detailed specification and direction of engineer in charge.

15

11

178.2

... More
1.1.1 - Supplying and fixing of class A (medium duty ) GI pipe of wall thickness not less than 3.25mm on pole / wall / drain crossing with necessary clamping arrangements for UG cable of 1.1 KV class 40 mm complete with all lead and lifts as per detailed specification and direction of engineer in charge.

3

345

1035

... More
page no15 item no 5.4.2 - Fabricating, supplying and mounting MS box made out of 16 SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, pvovided with hinged front cover, equip with tamper proof locking arrangements with suitable size clamps with necessary entry pipe with gland and box should be finished with two coats of red oxide, paint and finally finished with approved colour enameled metal paint, etc., complete with all lead and lifts as per detailed specification and direction of engineer in charge.

10800

-

4104



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.