Military Engineer Services Tender
... More
The MES has issued a formal invitation for competitive bids for the Military Engineer Services project, for Repairs Replacement Maintenance Of Ht Switch Gears Including Preventive Maint Of Vcbs Transformer Capacitor Banks Acbs Cabling And Other Connected Works Of External Electric Supply At Cabs Stir And Cemilac Under Ge I R And D East Bangalore in Bengaluru Urban, Karnataka, with an estimated contract value of Rs. 48,00,000. The bid opening date for this tender is 27-05-2025 and the last date for bid submission is 16-06-2025. Interested bidders for Military Engineer Services tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Military Engineer Services - MES Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date27 May 2025
Closing Date16 Jun 2025
Tender Amount₹ 48,00,000
Costs
EMD
₹ 96,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_705762_1Tender No
8602/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply only for replacement of Tripping coil complete all as specified and as directed.
4
-
-
... More
Supply only for replacement of Male & female contact complete all as specified and as directed.
5
-
-
... More
Supply only for replacement of safety shutter complete all as specified and as directed.
3
-
-
... More
Supply only for replacement of locking assembly complete all as specified and as directed.
4
-
-
... More
Supply only for replacement of Spring charge motor complete all as specified and as directed.
3
-
-
... More
Supply only for replacement of Circuit terminals complete all as specified and as directed.
3
-
-
... More
Supply only for replacement of Pole assembly complete all as specified and as directed.
2
-
-
... More
Supply only for replacement of NO Volt coil 110V DC complete all as specified and as directed.
3
-
-
... More
Supply only for replacement of Closing coil complete all as specified and as directed.
3
-
-
... More
Supply only for replacement of Arc chute complete all as specified and as directed.
2
-
-
... More
Supply only for replacement of Operating mechanism complete all as specified and as directed.
2
-
-
... More
Material and labour for maintenance, servicing and repair of Vaccum Circuit Breakers/Oil circuit breaker HT 11KV 400 Amps/ 800Amps 50 cycles, breaking capacity 13.5 KA of any make, by opening and checking the internal moving, fixed parts, contacts / wiring, cleaning, decarbonising, tightening loosened parts, operational checking of closing / tripping system, lubricating greasing all moving parts, replacing worn out part, copper studs, bolts, nuts, washers, Checking control wiring, oil, busbar, fixed contacts or moving contacts, HT bushes, gaskets including unserviceable coil, replacing of defective minor items such as indicators lamps, push buttons, selector switch etc as and when required complete all as specified and as directed. NOTE :- The item spare parts, oil to be replaced shall be measured and paid separately, However minor items such as nuts bolts, gasket, wiring, screws etc shall be deemed to be included in the unit rate quoted with providing the testing certificate as directed.
13
-
-
... More
Supply only PT fuses (11KV/8Amps HT 5 x UTF 11) with stem complete all as specified and as directed.
5
-
-
... More
Supply only for replacement of selector switch suitable for Voltmeter / Ammeter on HT OCBs / VCBs complete all as specified and as directed.
10
-
-
... More
Supply only for replacement of push botton on/off suitable for 11KV panel of existing size including removing old unserviceable of colour Red, Green, Blue ,Yellow (as per site requirement) complete all as specified and as directed.
10
-
-
... More
Supply only for replacement of indicator lamp assembly complete LED type suitable for 30V DC or 110V AC including fixing of HT OCB complete all as specified and as directed.
30
-
-
... More
Supply only for replacement of Three pole VCB main shaft assembly suitable for HT 11 KV complete all as specified and as directed.
3
-
-
... More
Supply only for replacement of vaccum Interpture bottol for the existing HT 11 KV VCB including taking out old unserviceable vaccume Interputure bottol complete all as specified and as directed.
3
-
-
... More
Supply only for replacement of shunt trip coil suitable for VCB / OCB of 400 Amps / 800 Amps capacity of 110 volt complete all as specified and as directed.
3
-
-
... More
Supply only for replacement of Master Tripping Relay rating of 24 / 30 / 110 V DC for the existing HT VCB / OCB / RMU 11 KV Panels complete all as specified and as directed.
4
-
-
... More
Supply only for replacement of closing coil / Tripping coil for 11 KV 400 Amp /800 Amps VCB 30 / 110 V DC including taking out old unserviceable coil complete all as specified and as directed.
5
-
-
... More
Supply only for replacement of Trip-Neutral-Close (TNC) Switch, fixing with the existing HT VCB / OCB 11 KV Panel for including taking out old unserviceable TNC Switch complete all as specified and as directed.
4
-
-
... More
Supply only for replacement of spring charging motor for 11 KV VCB suitable for the existing make including taking out old unserviceable one complete all as specified and as directed.
3
-
-
... More
Supply only for replacement of moving contact assembly suitable for HT VCB / OCB 11 KV 400 amps / 800 Amps VCB / OCB includes dismantling the old unserviceable moving contact assembly suitable for HT VCB/OCB complete all as specified and as directed.
5
-
-
... More
Supply only for replacement of Power Pack 110 VAC / 110 VDC includes dismantling the old unserviceable complete all as specified and as directed.
3
-
-
... More
Supply only for replacement of spout bushing for 11 KV VCB 400 / 800 Amps current rating size as per existing VCB complete all as specified and as directed by Engineer-in-Charge.
2
-
-
... More
Supply only for replacement of contacts for VCB 11 KV rating 400/800 Amps current rating heat resistant complete all as specified and as directed.
2
-
-
... More
Supply only for replacement of bus bar supporting bushing for 11 KV VCB of rating 400/800 Amps current rating heat resistant complete all as specified and as directed.
3
-
-
... More
Supply only for replacement of bus bar supporting insulator for 11 KV VCB of rating 400/800 Amps current rating heat resistant complete all as specified and as directed.
4
-
-
... More
Supply only for replacement of Latch assembly for 11 KV VCB of rating 400/800 Amps current rating heat resistant complete all as specified and as directed.
3
-
-
... More
Material and labour for calibration IDMT relays set of three through relay test kit including other required measuring equipment to the site by secondary injection method and testing for proper functioning / tripping systems of relays complete all as specified and as directed. NOTE : - The rate quoted by the contractor is deemed to be included for quarterly checking of relays in VCB/OBC for its proper setting/functioning and tripping of VCB/OCB during over load/earth fault.
13
-
-
... More
Supply and fix in replacement of old unserviceable PT with new potential transformer OIL Cooled with protective enclosure of ratio 11 KV/ 110 V /RT3/110V/RT3 Class 1.0/3P, Burden 100 VA/50 VA Voltage Factor 1.2 continuous / 1.5 for 30 seconds. ILV 12/28/75 KVP. Insulation class B Ref Std IS : 3156/1992 One end earthed type with one No HRC fuse on HV side.
MAKE : LAMCO / ABB / KALPA / SCHNEIDER. NOTE : Primary Neutral to be solidly earthed including removing of old unserviceable PTs.
1
-
-
... More
Supply and fix in replacement of old unserviceable PT with new potential transformer OIL Cooled with protective enclosure of ratio 11 KV/ 110 V /RT3/110V/RT3 Class 1.0/3P, Burden 100 VA/100 VA Voltage Factor 1.2 continuous / 1.5 for 30 seconds. ILV 12/28/75 KVP. Ins class B Ref Std IS : 3156/1992 One end earthed type with one No HRC fuse on HV side. MAKE : LAMCO / ABB / KALPA / SCHNEIDER.
NOTE :
Primary Neutral to be solidly earthed including removing of old unserviceable PTs.
1
-
-
... More
Supply and fix in replacement of old unserviceable CT with new LT CT, CT ratio 50/5-5A control relay panel and for protection complete all as specified and as directed (for APFCR panel).
MAKE : KALPA / INSTRANS
2
-
-
... More
Supply and fix in replacement of old unserviceable CT with new CT 11 KV, CT ratio 60/5-5A frequency 50/60 Hz control relay panel & for protection complete all as specified and as directed. MAKE : KALPA / INSTRANS
2
-
-
... More
Supply only hand gloves HT for operating /handling sub station of 11/33/66 KV ISI marked complete all as specified and as directed. MAKE : JAIPURIA BROTHERS or equivalent
2
-
-
... More
Material and labour for servicing of Capacitor Bank Panel, cleaning, dusting, decarbonising, tightening loosened parts checking of closing/tripping system, including replacing worn out parts copper studs, bolts nuts and washers, replacing control wires, bus bar contacts as and when required complete all as specified and as directed by Engineer-in-Charge.
NOTE : The items to be replaced shall be measured and paid separately. However minor items such as indicator, push button, selector switch, wiring cable shall be deemed to be included in the unit rate.
6
-
-
... More
Supply only for replacement Multi data meter size 96 x 96mm class 1.0, : 1/5 A (programmeable), PT : 0-690 V AC ( programmable), Aux supply : 80 - 300 V AC/DC (V, I, PF, Hz, KWH, KVARH, KVAH for capacitor panel complete all as specified and as directed by Engineer-in-Charge.
4
-
-
... More
Supply only for replacement of 25 KVAR capacitor 440 volt, 3 phase complete all as specified and as directed by Engineer-in-Charge.
14
-
-
... More
Supply only in replacement of 50 KVAR capacitor 440 volt, 3 phase complete all as specified and as directed by Engineer-in-Charge.
8
-
-
... More
Supply only in replacement of MCCB with accessories TP, 415 Volt fixed type 63 Amps with breaking capacity 18 KA complete all as specified and as directed by Engineer-in-Charge.
6
-
-
... More
Supply only in replacement of MCCB with accessories TP, 415 Volt fixed type 125 Amps with breaking capacity 18 KA complete all as specified and as directed by Engineer-in-Charge.
4
-
-
... More
Supply only in replacement of Contactor for 25 KVAR capacitor heavy duty 440 volt, 3 phase complete all as specified and as directed.
14
-
-
... More
Supply only in replacement of Contactor for 50 KVAR capacitor heavy duty contactor 440 volt, 3 phase complete all as specified and as directed.
4
-
-
... More
Supply only in replacement of plastic body exhaust fan for panel 220 volt, single phase complete all as specified and as directed.
8
-
-
... More
Supply only in replacement of APFC relay 12 stage auto / manual, type of measurement power factor, display type four segment LED four digit rated supply 320-460 V AC measurement accuracy:+ 2% including testing and commissioning complete all as specified and as directed.
2
-
-
... More
Supply only in replacement of illumination lamp 230 Volt AC / DC single phase complete all as specified and as directed.
20
-
-
... More
Supply only in replacement of control timer 230 Vol single phase complete all as specified and as directed.
4
-
-
... More
Supply only contactor 3 pole 440 volt 50 HZ MNX 50 complete all as specified and as directed.
5
-
-
... More
Supply only contactor 4 pole 440 volt 50 HZ A26-30-10 complete all as specified and as directed.
6
-
-
... More
Supply only contactor 4 pole 440 volt 50 HZ A16-30-10 complete all as specified and as directed.
12
-
-
... More
Supply and fix in replacement of digital display voltmeter suitable for HT OCBs,HT VCBs at various substation suitable for HT panel 1100 / 100 volts (auxiliary volts) including necessary connections and taking out old unserviceable complete all as specified and as directed.
MAKE : SCHNEIDER / ELMEASURE / L&T
10
-
-
... More
Supply and fix in replacement of digital type ammeter suitable for CT ratio 50 / 100 / 200 amps including necessary connections and taking out unserviceable ammeter complete all as specified and as directed. MAKE : SCHNEIDER / ELMEASURE / L&T
8
-
-
... More
Material and labour for filtration of transformer oil through stream line/high vaccum filtration plant for extracting moisture content in the oil and carbon deposits and bringing the di-electric strength not less than 40 KV for one minute with sphere gap of 2.5mm including checking the value of acidity of oil with a acidity test kit and submitting test report for Die electric strength and acidity of transformer oil before / after filteration complete all as specified and as directed. NOTE : The contractor should submit the Test sheet for all transformer in which dehydration of transformer oil carried out
7500
-
-
... More
Supply and filling of New transformer oil confirming to IS 335-1963 as amended and die electric strength not less than 60 KV for topping up / replacement of unserviceable transformer oil complete all as specified and as directed.
400
-
-
... More
Supply and fix in repair HT bushing rod complete with insulator and packing suitable for outdoor / Indoor type upto 400 KVA, 11KV rating transformers confirming to IS-334 complete with nut bolts brass studs and gasket of synthetic rubber bonded cork sheet complete all as specified and as directed by Engineer-in-Charge.
2
-
-
... More
All as per ser item No 14.00 above but of capacity above 500 KVA and upto 1000 KVA, 11KV rating
2
-
-
... More
Material and labour for maintenance, servicing and Oil Leakage arresting upto 400 KVA, 11KV rating, Distribution Transformer, providing necessary gaskets, Oil Seals, cleaning, dusting, decarbonising, tightening loosened parts, including replacing worn out part copper studs, bolts nuts and washers replacing oil Seals, HT bush, gasket including unserviceable coil, replacing of defective minor items such as and when required complete all as specified and as directed.
NOTE : The item spare parts oil to be replaced shall be measured and paid separately, However minor items such as GASKET, NUT and bolt shall be deemed to be included in the unit rate. The rates are inclusive of crane charges for lifting and re assembling from the structure.
1
-
-
... More
All as per ser item No 16.00 above but of capacity above 500 KVA to 1000 KVA, 11KV rating.
4
-
-
... More
Supply and fix in repairs LT bushing complete with insulator and packing suitable1100 volt grade complete with nut, bolts, brass studs, insulator and gasket etc suitable for upto 400 KVA, 11 KV rating out door / Indoor transformer complete all as specified and as directed.
2
-
-
... More
All as per ser item No 18.00 above but for above 500 KVA to 1000 KVA, 11KV rating.
NOTE FOR Sl ITEM No. 16.00 to 19.00 :- (a) Rates quoted by the contractor shall be deemed to include for opening of top plate of transformer / decanning of oil from transformer up the level as per requirement and assemble the same after replacement of bushing rod.
(b) Bushing rod shall be replaced at site. transformer will not be allowed to send to workshop at any cost and all bushing replacement work shall be executed at site only.
2
-
-
... More
Material and labour for painting distribution transformer with two coats of synthetic enamel paint of smoke grey colour after neatly cleaning and preparing the surface for the transformer including all bus ducts of the following capacity including writing SM / MES No (5 cm height) with white enamel paint complete all as specified and as directed.
-
-
-
... More
200 KVA TO 400 KVA
2
-
-
... More
800 KVA TO 1000 KVA
6
-
-
... More
Supply and fix in repair silica gel breather assembly transparent type with first fill of silica gel suitable for upto 400 KVA, 11 KV rating (1/2 kgs) transformers including connecting with proper rubberized gasket complete all as specified and as directed.
2
-
-
... More
Supply and fix in repairs silica gel breather assembly transparent type with first fill of silica gel suitable for 1000 KVA (1 kg) transformers including connecting with proper rubberized gasket complete all as specified and as directed.
6
-
-
... More
Material and labour for removing, transporting the indoor / outdoor type transformers of capacity 630 KVA to 1000 KVA from one location to work shop to carry out the necessary repairs or rewinding / modifications of HT/LT indoor / outdoor transformer. After dismantling HT/LT side carefully and removing primary and secondary terminals, top cover, conservator tank, neutral earth strips and draining out the transformer oil to the required level and storing carefully in cleaned containers, cleaning of terminals, inspection of core replacing the 5mm thick rubberise cork sheet gasket for tank top cover reassembling the complete dismantled items, reconnecting the HT/LT supply cable ends at the site complete all as specified and as directed.
1
-
-
... More
All as per ser item No 23.00 above but of transformer of capacity 200 to 400KVA
1
-
-
... More
Material and labour for rewinding of HT/LT transformers by winding the defective coils with copper wire as existing of same gauge / size together with new material and aluminium bracings before placing into the transformer and assembling the HT/LT coil with new insulation between core and LT coil and fixing the coil in the chamber, testing and commissioning the transformer and recording the test result up to satisfaction levels of Engineer-in-Charge complete all as specified and as directed.
150
-
-
... More
Supply, fix, jointing and testing, end termination joint kit heat shrinkable indoor type, suitable for HT 11 KV XLPE cable 3 core 120 to185 sq.mm with necessary jointing materials including connecting etc including taking down unserviceable end joint complete and laying on floor / trenches complete all as specified and as directed.
1
-
-
... More
Supply, fix, jointing and testing, end termination joint kit heat shrinkable indoor type, suitable for HT 11 KV XLPE cable 3 core 95 sqmm with necessary jointing materials including connecting etc including taking down unserviceable end joint complete and laying on floor/trenches complete all as specified and as directed.
1
-
-
... More
Supply and fix in replacement HT End 11KV XLPE cable end joint Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size shrinkable type outdoor 3 core 50 to 95 Sqmm complete all as specified and as directed.
1
-
-
... More
Supply and fix in replacement HT End 11KV XLPE cable end joint Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size shrinkable type outdoor 3 core 120 to 185 Sqmm complete all as specified and as directed.
1
-
-
... More
Supply and fix in replacement HT straight through 11KV XLPE cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size shrinkable type outdoor 3 core 50 sqmm to 95 Sqmm 3 core UG cable complete all as specified and as directed.
1
-
-
... More
Supply and fix in replacement HT straight through joint heat 11KV XLPE cable end joint Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size shrinkable type outdoor 3 core 120 sqmm to 185 Sqmm 3 core UG cable complete all as specified and as directed.
1
-
-
... More
Supply and fix in replacement cable jointing kit for LT 1100 Volt grade cable for straight through joint complete with jointing material (epoxy based) and accessories suitable for XLPE / PVC armoured with aluminium conductor cable of following sizes including taking out the loop of defective cable complete all as specified and as directed.:-
-
-
-
... More
185 to 240 Sqmm 3.5 Core
2
-
-
... More
300 sqmm 3.5 core
1
-
-
... More
NOTE FOR ITEM NO 26.00 to 32.02 :- Excavation and earth work will be measured and paid separately under relevant items of BOQ.
-
-
-
... More
Supply and fix in replacement MCCB 3 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA rupturing capacity in existing panel board including modification on existing panel including complete connection as required at site and taking down old unserviceable MCCB complete all as specified and as directed.
3
-
-
... More
Supply and fix in replacement MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KArupturing capacity in existing panel board including modification on existing panel including complete connection as required at site including taking down old unserviceable MCCB complete all as specified and as directed.
2
-
-
... More
Supply and fix in replacement MCCB 4 Pole, 415 V, Adjustable type,630 Amps, with breaking capacity 50 KA rupturing capacity in existing panel board including modification on existing panel including complete connection as required at site including taking down old unserviceable MCCB complete all as specified and as directed.
3
-
-
... More
Supply and fix in replacement MCCB 3 Pole, 415 V, Adjustable type, 800 Amps, with breaking capacity 50 KA rupturing capacity in existing panel board including modification on existing panel including complete connection as required at site including taking down old unserviceable MCCB complete all as specified and as directed.
1
-
-
... More
Supply and fix in replacement MCCB 4 Pole, 415 V, Adjustable type, 800 Amps, with breaking capacity 50 KA rupturing capacity in existing panel board including modification on existing panel including complete connection as required at site including taking down old unserviceable MCCB complete all as specified and as directed.
1
-
-
... More
Supply and fix in replacement Gang operated Air Break switch tilting type combined with drop out fuse complete set of 400Amps including replacement of HT jumpers proper fixing with clamping on HT pole and including taking down of old unserviceable complete connections as directed by Engineer-in-Charge.
1
-
-
... More
Supply, install, commissioning and testing of ACB 4 pole 415 V, manual Draw out type with micro processor release of capacity 1600 amps 4 pole 50 KA in existing panel board with complete wiring connection including cutting / modification of panel if required including taking down of old unserviceable one complete all as specified and as directed by Engineer-in-Charge.
1
-
-
... More
Material and labour for Earthing complete with chemical earthing with copper plate 900x600x 3.15 mm as earthing lead buried directly in ground vertically to depth not less than 2.25 mtr below GL with the top edge of the plate not less than 1.5 mtr from GL, connected to copper earth strip of 32 x6 mm by means of bolts & nuts, to GI and connected to earthing test point all as shown in electrical plate No-5 of SSR part -1 of 2009 * specified or indicated and testing on completion including excavation /earth work in any type of starta PCC (1:3:6) type C1 earthing chamder pre cast slab 50 mm thick in cement concrete (1 : 2 : 4 ) type B1 , Reinforced with welded steel wire fabric (XPM) weight not less than 4 KG /sqm cast iron frame ,funnel with wire mesh GI watering pipe of 20 mm bore medium grade and lugs with and including copper strip 32X6 mm strip as earthing lead.7.5 meter long complete all as specified and as directed
1
-
-
... More
Supply and fix Copper strip 32mm x 6 mm buried in ground including excavation / refill with 40mm light grade pipe all as directed by Engineer-in-Charge.
20
-
-
... More
Supply and fix Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / GI pipe or fixed to poles or any other indicated situation for loop earthing etc as required of GI strip 32 x 6 mm complete all as specified and as directed.
15
-
-
... More
Labour only to find HT / LT cable fault of any rating through BESCOM by using High pot Test tool kit from BESCOM to locate the HT fault .If any jointing kit required then measured and paid separately.
NOTE : No any additional cost to be provided to contractor for T & P.
4
-
-
... More
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 KV (size 2x1m) for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and as directed.
30
-
-
... More
Material and labour for servicing of 4 pole structure including replacement of all jumpers with proper lugs / thimble, painting the structure and channels/cross arms, replacement of worn out nuts bolts, replacement of blown fuses, trimming of surrounding trees branches including painting to the structure with aluminium paint complete all as specified and as directed.
NOTE : (a) Proper shut down to be taken in advance from BESCOM.
(b) All Safety precautions to be taken by the contractor without any extra cost.
2
-
-
... More
Material and labour for fixing and connection of lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amp of rating 11 KV complete all as specified and as directed.
1
-
-
... More
Material and labour for painting of HT OCB/VCB or LT panels of any size not more than 2.50 x .86 x 1.80 m with two coats of powder coated paint after scrapping old paint, filling of cabities if any, wrapping of all meters, relays, push buttons, indicators etc before paint including repair to the hinges and locking system, cleaning inside the panel, including writing SM/MES No/danger and as per existing (5 cm height) complete all as specified and as directed by Engineer-in-Charge.
25
-
-
... More
Cleaning of out door Sub Station by cutting and removing vegetation growth and surface levelling complete all as specified and as directed.
2000
-
-
... More
Maintenance and servicing of battery panel 220/110/30/24 V DC with battery 55 Nos and its control Panels wiring, PCB, Relays and terminal cables with replacement of defective parts with new one including testing and servicing battery charges complete all as specified and as directed.
1
-
-
... More
Material and labour for servicing of 415 Volt electrical panel indoor / outdoor type for cleaning of dust particle inside the panel like MCCB, relay / contactor with help of blower etc and tightening of all electrical connection and complete testing and replacement of burnt lugs etc complete all as specified and as directed.
8
-
-
... More
Material and labour for cutting/trimming of tree branches which are touching to four pole/two pole structure and clearing the same up to 4 mtr radius for span length not exceeding 10 to 15 metre and removing the same n ecx 50 m or as directed complete all as specified and directed by Engineer-in-Charge.
NOTE : Each span of 10 to 15 mtrs will be considered as one length of span for payment purpose.
10
-
-
... More
Taking down in trenches, fixed on walls, passing through pipes, jointing and testing of electric LT UG cables 240 Sqmm 3.5 core, PVC insulated, PVC sheathed, galvanised steel strip or wire armoured electric power cables with stranded aluminium conductors 1100 Volts grade complete all as specified and as directed by Engineer-in-Charge.
250
-
-
... More
Supply and laying in trenches, fixed on walls, passing through pipes, jointing and testing of electric LT UG cables of size 240 sqmm 3.5 core, PVC insulated, PVC sheathed, galvanised steel strip or wire armoured electric power XLPE cables with stranded aluminium conductors 1100 Volts grade complete all as specified and as directed by Engineer-in-Charge.
250
-
-
... More
Excavation in trenches n. exc. 1.5m wide and n exc. 1.5m in depth for taking out/laying cables in soft / loose soil complete all as specified and as directed.
27
-
-
... More
Material and labour for sand filling (pulverized stone dust) for cable cushioning including spreading and levelling complete all as specified and as directed.
NOTE : Punned thickness only will be measured and paid.
6.75
-
-
... More
Material and labour for well burnt bricks, laid flat ( old size) sub class B designation 75 for cable protection complete all as specified and as directed by Engineer-in-Charge.
870
-
-
... More
Returning filling in, including, spreading, leveling, watering and well ramming in layers n exc. 25 cm complete all as specified and as directed.
16.75
-
-
... More
Removing excavated material to a distance n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
10.25
-
-
... More
Material and labour for cutting of bituminous road / floor for laying of pipe/cables not exc 1.5 mtr wide and not exceeding 1.5 mtr deep including refilling/with material and watering well ramming/compacting and making good with PCC 1:3:6 complete all as specified and as directed by Engineer-in-Charge.
NOTE : PCC will be measured and paid under relevant items.
10
-
-
... More
Material and labour for PCC (1:3:6) type C1 using 20 mm graded aggregate for making good the disturbed portion of road / floor/ platform / foundation of RMU unit etc including form work completion etc complete all as specified and as directed.
3
-
-
... More
Supply and laying of GI pipe galvanised medium grade of 80 mm dia for protection of cable across road including taking down of old unserviceable complete all as specified and as directed by Engineer-in-Charge.
20
-
-
... More
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern top covering of bus bar chamber after taking proper shutdown of electric supply complete all as specified and as directed.
20
-
-
... More
Supply and fix Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering of bus bar /cladding to wall, fixed with self tapping screws including all T&P / scaffolding required if any complete all as specified and as directed.
20
-
-
... More
Preparation of old steel surface of any description over 10 cm width or girth and applying one coat of synthetic enamel paint as per existing colour complete all as specified and as directed.
60
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%