Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Mangalore Electricity Supply Company Limited - MESCOM Tender

Civil And Construction
Building Construction
Opening Date6 Mar 2024
Closing Date6 Apr 2024
Tender Amount₹ 2,26,26,887.92 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
004 - Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1/3/6 (M10) Using 20 mm nominal size graded crushed coarse aggregates

24

6963

167112.96

... More
005 - Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.-m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (For footings and sump tanks)

85

7664

651442.55

... More
006 - Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam )

25

10886

272160

... More
007 - Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Ground Floor ) (column)

9.4

13029

122473.258

... More
008 - Lintel

2.38

12262

29185.1308

... More
009 - Roof Beam

13

12262

159414.58

... More
010 - Chejja

0.6

11113

6667.818

... More
011 - Staircase

6.35

11496

73001.124

... More
012 - Roof Slab

44

11496

505834.56

... More
013 - Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.m25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Retaining wall)

92

7983

734469.12

... More
014 - first floor Column

9.8

13159

128961.728

... More
015 - First floor Lintel

6.2

12385

76788.736

... More
016 - first floor Roof Beam

22.4

12385

277430.272

... More
017 - first floor Slab

59

11611

685060.8

... More
018 - first floor Staircase

6.27

11611

72802.224

... More
019 - First floor Chejja

1.4

11224

15713.824

... More
020 - Second Floor Column

9.8

13289

130238.57

... More
021 - second floor Lintel

6.8

12507

85053.788

... More
022 - second floor Roof Beam

23

12507

287681.93

... More
023 - second floor Slab

60

11726

703569.6

... More
024 - second floor Staircase

6.27

11726

73523.0232

... More
025 - second floor Chejja

1.6

11335

18136.464

... More
026 - Terrace Floor column

3

13419

40259.82

... More
027 - Terrace FloorLintel

2.6

12630

32839.404

... More
028 - Terrace FloorRoof Beam

3.72

12630

46985.6088

... More
029 - Terrace Floor Slab

4.6

11841

54469.198

... More
030 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings (Ground Floor)

23.95

100191

2399594.568

... More
031 - First Floor

9.33

101193

944137.7808

... More
032 - Second Floor

9.63

102195

984144.3984

... More
033 - Terrace Floor

0.93

103197

95973.768

... More
034 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

340

297

101292.8

... More
035 - Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work

170

530

90249.6

... More
036 - Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)

25

7155

178892

... More
037 - Providing & constructing Laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specifications. I.S. 3620/1979 having compressive strength not less than 3.5N/mm2 for saturated dry samples FOR SUPER STRUCTURE in C.M:1:6 (Ground Floor)

80

7565

605248

... More
038 - First Floor

85

7641

649507.1

... More
039 - Second Floor

113

7716

872010.83

... More
040 - Terrace Floor

48

7792

374043.36

... More
041 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Ground Floor)

15

1378

20680.8

... More
042 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (Ground Floor)

7.3

1236

9026.304

... More
043 - first Floor

7.3

1248

9116.532

... More
044 - Second Floor

7.3

1261

9206.833

... More
045 - Terrace Floor

90

1273

114621.3

... More
046 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.(First Floor)

180

553

99568.8

... More
047 - second floor

172

558

96084.36

... More
048 - Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.(First Floor)

10.8

645

6975.936

... More
049 - Second Floor

11

652

7175.41

... More
050 - Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(First Floor)

42

1117

46940.46

... More
051 - Second Floor

42

1128

47404.98

... More
052 - Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin- charge: Pre-laminated particle board with decorative lamination on both sides including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (First Floor)

42

1111

46702.74

... More
053 - Second Floor

42

1122

47165.16

... More
054 - Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (Ground Floor)

0.2

154642

30928.576

... More
055 - First Floor

0.15

156189

23428.3965

... More
056 - Second Floor

0.15

157735

23660.361

... More
057 - Terrace Floor

0.1

159282

15928.217

... More
058 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. - -do- 30 mm thick both side commercial (Ground Floor)

9

3365

30290.4

... More
059 - First Floor

6

3399

20395.56

... More
060 - Second Floor

6

3432

20597.46

... More
061 - Terrace Floor

3

3466

10399.71

... More
062 - Providing and fixing factory made pre fabricated non-monolithic Premium R.C.C. Door Frames factory manufactured in separate parts and assembled at bolts nuts system with mechanical table vibrating as per IS 6523-1983 with using m25 concrete as per IS 456 and reinforced with 1.70 kg of TMT steel reinforced with 3 No. of 6 mm dia Main TMT bars and 6 mm Dia TMT stirrups welded at 40 cm c/c in triangle shape per meter length of door frames, including cost of steel and fabrication charges having 4 No. of 304 Grade Stainless Steel hinges plate attachment made of 165 mm x 25 mm x 2.5 mm Stainless Steel Flat welded with required iron rods and flats with drilling for fixing flat CSK Head Machine screws made out of 304 grade stainless steel screws and MS square nuts of size 8 x 8 square and length 10 mm and making necessary provision in concrete for fixing aldrops, tower bolts and hold fasts etc., complete including two coats of oil based enamel primer providing without cill for shutter thickness upto 32 mm, 21 days tank immersed curing including cost of labour, materials, usage charge of machinery complete excluding the cost of door fixtures as per the direction of Engineer. Cross section of 60 mm x 100 mm (Ground Floor)

11.6

963

11173.12

... More
063 - First Floor

11.6

972

11284.828

... More
064 - Second Floor

17.5

982

17193.05

... More
065 - Providing and fixing to existing door frames 30mm thick glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacture made with fire retardent frade unsaturated polyster resin, moulded to 3mm thick FRP laminate for forming hollow rails and styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP laminate for panels confirming to IS:14856, including fixing to frames. (Ground Floor)

3.2

3588

11483.136

... More
066 - First Floor

3.2

3624

11597.952

... More
067 - Second Floor

4.73

3660

17312.9825

... More
068 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Ground Floor)

140

632

88592

... More
069 - First Floor

70

639

44739.1

... More
070 - Second Floor

70

645

45182.2

... More
071 - Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P s shall not be made) (Ground Floor)

8.2

7542

61845.056

... More
072 - First Floor

32.5

7617

247568.75

... More
073 - Second Floor

35.2

7692

270790.784

... More
074 - Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mm height with nforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi einforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) ( first floor)

6.8

6097

41460.756

... More
075 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P s shall not be made)-GF,FF,TF (Ground Floor)

1

6405

6405.28

... More
076 - First Floor

1

6469

6469.33

... More
077 - Second Floor

1.4

6533

9146.746

... More
078 - Providing and fixing M.S. grills of required pattern in frames of win dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. (Ground Floor)

190

188

35750.4

... More
079 - First Floor

700

190

133028

... More
080 - Second Floor

760

191

145859.2

... More
081 - Terrace floor

115

193

22287

... More
082 - Providing and fixing Steel work welded in built up sections framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer Using structural steel etc . as required in stringers, treads, landinf etc of stair cases, including use of chequered plate wherever required, all complete including cost of materials, labour, usage charges of machinerycomplete as per specifications and as per directions of the Engineer-in Charge.

620

126

78467.2

... More
083 - Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of theEngineer-in-Charge.

242

2948

713648.32

... More
084 - Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. (Second floor)

4.3

2326

10005.283

... More
085 - Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) (Second floor)

1.5

702

1053.87

... More
086 - Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. (Terrace floor)

352

942

331756.48

... More
087 - Providing and laying water proofing treatment to the Water tanks & Liq uid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification

63

567

35773.92

... More
088 - Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge Ceiling Plastering. (Ground Floor)

200

269

53984

... More
089 - First Floor

340

272

92690.8

... More
090 - Second Floor

340

275

93608.8

... More
091 - Terrace floor

86

278

23909.72

... More
092 - Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (inside walls) (Ground Floor)

360

372

134265.6

... More
093 - First Floor

625

376

235431.25

... More
094 - Second Floor

700

380

266294

... More
095 - Terrace floor

92

384

35341.8

... More
096 - Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge (out side wall) (Ground Floor)

375

372

139860

... More
097 - First Floor

315

376

118657.35

... More
098 - Second Floor

325

380

123636.5

... More
099 - Terrace floor

265

384

101799.75

... More
100 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Ground Floor)

340

112

38080

... More
101 - First Floor

610

113

69003.2

... More
102 - Second Floor

680

114

77683.2

... More
103 - Terrace floor

95

115

10959.2

... More
104 - Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m2over and including one coat of Special primer applied @ 0.75 ltr /10 m2 with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (Internal Painting). (Ground Floor)

340

176

60166.4

... More
105 - First Floor

610

178

109025.3

... More
106 - Second Floor

680

180

122740

... More
107 - Terrace floor

95

182

17315.65

... More
108 - Outside Painting (Ground Floor)

375

176

66360

... More
109 - Outside Painting First Floor

315

178

56299.95

... More
110 - Outside Painting Second Floor

325

180

58662.5

... More
111 - Outside Painting Terrace floor

265

182

48301.55

... More
112 - Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge (including primer) Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Ground Floor)

130

243

31595.2

... More
113 - First Floor

34

245

8345.98

... More
114 - Second Floor

40

247

9916

... More
115 - Terrace floor

5.5

250

1376.815

... More
116 - Providing and fixing magnetic door stopper with necessary screws, etc. complete. (Ground Floor)

4

300

1200

... More
117 - First Floor

5

300

1500

... More
118 - Second Floor

6

300

1800

... More
119 - Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete- Size of Tile 600x600 mm (Ground Floor)

42

1282

53860.8

... More
120 - First Floor

280

1295

362661.6

... More
121 - Second Floor

280

1308

366254

... More
122 - Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. (Ground Floor)

72

3194

229985.28

... More
123 - First Floor

40

3226

129047.2

... More
124 - Second Floor

40

3258

130324.8

... More
125 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (Ground Floor)

7.5

995

7467.6

... More
126 - First Floor

7.5

1005

7542.3

... More
127 - Second Floor

7.5

1015

7616.925

... More
128 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (Ground Floor)

25

1622

40572

... More
129 - First Floor

23

1639

37699.53

... More
130 - Second Floor

23

1655

38072.82

... More
131 - Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with ce ment mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications. (Ground Floor)

45

4792

215661.6

... More
132 - First Floor

30

4840

145212

... More
133 - Second Floor

30

4888

146649.9

... More
134 - Providing SBC of the soil by conducting test through engineering college , block levelling of the site, surveying of the site and submitting structural design and drawings of the building from the structural engineer. (quotation rate)

1

182000

182000

... More
135 - providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.

500

896

448000

... More
136 - Wet Mix Macadam (Plant mix method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.

25

2866

71652

... More
137 - Glass Door cum fixed glass partitions using Jindal anodised section of 4 x 2 on all sides of glass and door completely along with 4 numbers of SS handle of 450mm long.

6

6500

39000

... More
138 - Fixing charges for door fixtures and other fitting of pipe lines (Market Rate)

1

32000

32000

... More
139 - Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.

4

5418

21674.24

... More
140 - Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

3

5470

16410.24

... More
141 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.

4

3451

13807.36

... More
142 - Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern.

3

7598

22794.24

... More
143 - Installing, testing and commissioning of approved make 15 mm CP health faucet with CP flexible tube 1.0m long, CP crutch, nozzle etc.,complete.

4

1800

7200

... More
144 - Providing and fixing brass stop cock of approved quality : 20 mm nominal bore Jal or equivalent

12

341

4099.2

... More
145 - Providing and fixing brass bib cock of approved quality : 20 mm nominal bore Jal or equivalent

12

341

4099.2

... More
146 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 32 mm nominal bore

5

669

3348.8

... More
147 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore.

3

614

1844.64

... More
148 - Providing and placing on terrece polythene water storage tank , IS : 12701 marked with cover and suitable locking arragements and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.2000 litres

2000

10

20160

... More
149 - Providing and fixing 100 mm sand cast Iron grating for gully trap/ Nahani trap

5

52

263.2

... More
150 - Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13593 type A, including jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expansion, (i) single socketed pipes -100mm dia100mm

150

325

48888

... More
151 - Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13593 type A, including jointing with seal ring confirming to IS:5382 leaving 10mm gap for thermal expansion, (i) single socketed pipes -100mm dia100mm 75mm

100

220

22064

... More
152 - Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1/2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.

4

4744

18977.28

... More
153 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.

4

6108

24433.92

... More
154 - Providing and fixing chlorinated Poly Venyl Chloride(CPVC) pipes confirming to IS 15778 having thermal stability for hot and cold water supply incluidng all CPVC plain and brass threaded fittings i.e. fixing the pipes with clamps at 1.00m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer incharge. Concealed work including cutting chases and making good the wall etc., 1st Addendum order 25mm

80

534

42739.2

... More
155 - Providing and fixing chlorinated Poly Venyl Chloride (CPVC) pipes confirming to IS 15778 having thermal stability for hot and cold water supply incluidng all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00mtr spacing.This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer incharge. (Exposed on wall) 20mm nominal dia

90

271

24393.6

... More
156 - Providing and fixing chlorinated Poly Venyl Chloride(CPVC) pipes, having thermal stability for hot and cold water supply incluidng all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of engineer incharge. -External work 40mm dia

75

534

40068

... More
157 - Providing and fixing chlorinated Poly Venyl Chloride(CPVC) pipes, having thermal stability for hot and cold water supply incluidng all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of engineer incharge. -External work 32mm dia

80

416

33331.2

... More
158 - Providing and fixing gun metal non- return valve of approved quality (screwed end) : 32 mm nominal bore Vertical

4

1036

4144

... More
159 - Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for open well motor including the suction pipe,non return valve flexible Green pipe pipe etc cpomplete [each work]confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments.-1.50 HP/1.1KW - 20 STG

1

20404

20404.16

... More
160 - Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.

5

555

2777.6

... More
161 - Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm

4

1140

4560.64

... More
162 - Supplying and wiring adopting loop system in existing PVC Conduit/casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box,the other end of the wires shall be terminated with sufficient looselength in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box

20

269

5380

... More
163 - Medium point above 3Mtr upto 6mtr from tapping point to outlet via switch box

30

379

11370

... More
164 - Long point above 6 mtr upto 10mtr from tapping point to out let via switch box

15

555

8325

... More
165 - Two outlet in a row, above 3mtr upto 6mtr from tapping point to out let via switch box.

10

677

6770

... More
166 - Three outlet in a row, above 6mtr upto 10mtr from tapping point to out let via switch box

1

989

989

... More
167 - Concelled Conduit System : Supplying heavy gauge PVC conduit pipe mm dia..mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thick

250

66

16500

... More
168 - Concelled Conduit System : Supplying heavy gauge PVC conduit pipe mm dia..mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thick 25mm dia 2mm thick

300

78

23400

... More
169 - Concelled Conduit System : Supplying heavy gauge PVC conduit pipe mm dia..mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thick 32mm dia 2mm thick

50

103

5150

... More
170 - Groove cutting : Supplying...dia 2mm/2.5mm thick heavy gauge PVC Conduit pope with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever neccessary. 19/20mm dia 2mm thick

100

68

6800

... More
171 - Groove cutting : Supplying...dia 2mm/2.5mm thick heavy gauge PVC Conduit pope with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever neccessary. 25mm dia 2m thick

100

79

7900

... More
172 - Groove cutting : Supplying...dia 2mm/2.5mm thick heavy gauge PVC Conduit pope with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever neccessary.32mm dia 2.5mm thick

25

99

2475

... More
173 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:201. 1.5 mm2

700

26

18200

... More
174 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:201. 2.5 mm2

1000

42

42000

... More
175 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:201.4 mm2

250

63

15750

... More
176 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:201.6 mm2

100

92

9200

... More
177 - Supplying and fixing PVC/metal conduit Deep junction box-19/20mm deep junction box

20

49

980

... More
178 - Supplying and fixing PVC/metal conduit Deep junction box-25mm deep junction box

20

56

1120

... More
179 - Supplying and fixing of Metal Fan Box with Round Hook.

20

117

2340

... More
180 - Extra length of GI pipe of class B 19mm dia for down rod.

13.2

197

2600.4

... More
181 - SWITCHES, SOCKETS & ACCESSORIES. Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall

55

159

8745

... More
182 - SWITCHES, SOCKETS & ACCESSORIES. Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. 5 Way

10

177

1770

... More
183 - SWITCHES, SOCKETS & ACCESSORIES. Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall6 Way

30

220

6600

... More
184 - SWITCHES, SOCKETS & ACCESSORIES. Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall8 Way

10

261

2610

... More
185 - SWITCHES, SOCKETS & ACCESSORIES. Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall10-12 Way

5

319

1595

... More
186 - SWITCHES, SOCKETS & ACCESSORIES. Supplying and flush mounting powder coated / galvanised metal box suitable for mountting modular switch plates. The box should be firmly mounted after due groove cutting in Brick/Stone/C.C. wall16 Way

1

363

363

... More
187 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.3 Module

55

161

8855

... More
188 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.4 Module

10

175

1750

... More
189 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.6 Module

30

234

7020

... More
190 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.8 Module

10

284

2840

... More
191 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.10 Module

5

344

1720

... More
192 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.16Module

1

397

397

... More
193 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A one way

130

102

13260

... More
194 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A two way switch

6

166

996

... More
195 - Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A two way switch 6A three way socket.

40

171

6840

... More
196 - Stepped Fan Regulator two module

20

357

7140

... More
197 - one way switch. 16A

10

180

1800

... More
198 - Bell Push. 6A

3

177

531

... More
199 - switch 32A DP

3

326

978

... More
200 - Universal Socket 6/16A

10

236

2360

... More
201 - TV/Telephone Socket.

15

156

2340

... More
202 - RJ 45/I.O Out let Cat 6

25

337

8425

... More
203 - CONTROL SWITCH GEARS & ACCESSORIES. Supplying and fixing miniature circuit breaker on existing MCB distribution board using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring confirming to IEC 60898. 6-32 Amps SP

20

415

8300

... More
204 - DP 40 A

6

1060

6360

... More
205 - Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.16-25A,2 pole

3

4277

12831

... More
206 - Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB s single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. 4 Way SP & N Ups Input

2

1241

2482

... More
207 - SP &N LDB/PDB/UDB 12 way

3

1863

5589

... More
208 - NETWORKING & TELECOMMUNICATION. /CC TV Supplying and drawing PVC flexible TWO pair telephone unarmoured tinned copper cable. -2 Pair.

200

21

4200

... More
209 - Supplying and drawing UTP-CAT 6E LAN Cable

350

38

13300

... More
210 - Supply and Fixing of MDF Krone junction boxes with KRONE module/telephone cable termination 10 pair

1

345

345

... More
211 - Supplying heavy gauge PVC conduit pipe . dia .mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws 19/20mm dia 2mm thick

120

69

8280

... More
212 - dia 2mm thick 25mm dia

150

81

12150

... More
213 - Supplying & Fixing of switch mounting rack with power manager & Cable manager -9U with 450mm depth

1

8476

8476

... More
214 - patch Panel 24 port 10/100

1

4100

4100

... More
215 - Supplying & Fixing of 2 m Cat 6 Patch Cable

15

257

3855

... More
216 - Supplying & Fixing of 1 m Cat 6 Patch Cable

15

224

3360

... More
217 - Fixing all types and all capacities of flouroscent / false ceiling / spot light / CFL / LED fittings on the wall / ceiling / rafters / girders using 23/0.0076 twin twisted PVC insulated wires, required nos. of round blocks & clamps. On wall / ceiling / rafter / girders

50

122

6100

... More
218 - Fixing a ceiling /wall mounting fan of all capacities and all types,with necessary clamps and S hook made out of 15mm dia MS rod,with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality mounted on a suitable size wooden board and wired.

20

171

3420

... More
219 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.

4

492

1968

... More
220 - Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.

3

162

486

... More
221 - EARTH STATION & EARTH TAPE. Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10ft. SS rod with backfill compound

7

6230

43610

... More
222 - GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x6 mm GI strip

20

128

2560

... More
223 - Supplying & Fixing of 230 V 20/40 W Fluorescent Lamp holder

3

33

99

... More
224 - Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.

3

246

738

... More
225 - Bakelite Ceiling Rose 6A

50

78

3900

... More
226 - Supplying 1.1KV LT UG cable having aluminium conductor PVC insulated, extruded inner sheathed, galvanised, steel strips : 2.5 to 25 Sqmm (Single/3.5/4 Core)

0.2

1187

237.4

... More
227 - Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm

0.2

20886

4177.2

... More
228 - Supply and fixing of Brass Cable Gland 45 mm

2

197

394

... More
229 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism THREE Pole100Amps ,25KA, FP for Panel EB Incomer

1

6086

6086

... More
230 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 . 6-32 Amps DP -FOR Outgioing

8

739

5912

... More
231 - Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN FOR OUT GOING

2

3088

6176

... More
232 - Supplying 100. Amps rated 3 phase with neutral bus bar using requirement capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/ DMC insulator which are mounted on powder coated 40*6mm M.S flat frame work in exisisting panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. : 100Amps 4x30x6mm Alluminium Strips - 100Amps , 4x50x10xmm AL strips

5

2465

12325

... More
233 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. - 50x50x6mm

5

395

1975

... More
234 - Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.14 SWG

30000

-

15000

... More
235 - Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter

1

5705

5705

... More
236 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for r 230/440VAC. 50 Hz 12/24V D.C.

4

515

2060

... More
237 - Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V -125A

1

45000

45000

... More
238 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board

1

9255

9255

... More
239 - Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter.

2

1425

2850

... More
240 - Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound

3

562

1686

... More
241 - Supply and Installation of Surge Protection Device (SPD) with 63A 4P Isolator.-Market rate ( OBO /DEN Make )

1

17500

17500

... More
242 - Supplying of feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x4 -20/22watt

35

690

24150

... More
243 - Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x2 - 9/10watt

9

551

4959

... More
244 - Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48 Sweep (1200 mm) Regular model

30

2984

89520

... More
245 - Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12 Sweep (300 mm)

4

2969

11876

... More
246 - Supply of round/square recess/surface mounted rolling type LED Down light with W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition- LED square or round down light 15-18W

10

1324

13240

... More
247 - Supplying of recess mounting non integral type LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly.with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 1x4 34-36W

6

5898

35388

... More
248 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia Lumileds/Osram make LED Source.Supply of LED Streetlight 70 watts

3

5995

17985

... More
249 - Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete-5 kVA ON LINE UPS

1

68383

68383

... More
250 - Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. - 60 /65 AH capacity

6

6413

38478



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.