Krishna Bhagya Jala Nigam Limited Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Krishna Bhagya Jala Nigam Limited - KBJNL Tender

Civil Works
Opening Date4 Mar 2021
Closing Date22 Mar 2021
Tender Amount₹ 22,48,38,117 
This is an estimated amount, exact amount may vary.
Notes
Download

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work excavation for foundation of structures by mechanical means as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising / transporting the remaining earth locally upto 1.00km lead. (Depth upto 3.00 Mts) -In all types of soil, including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

2485

-

135681

... More
Earth work excavation for foundation of structures by mechanical means as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising / transporting the remaining earth locally upto 1.00km lead. (Depth upto 3.00 Mts) - Soft rock/ordinary rock (without blasting), including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

1873.38

-

133759.33

... More
KSRB 2-2-1: Earthwork excavation for foundation of building, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Ordinary soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavagtion with lead upto 50m. after breaking of clods complete as per specifications Specification. No. KBS 2.1 (a)/2.3.5 . including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

1098.04

-

344729.66

... More
KSRB 2-2-2: Earthwork excavation for foundation of building, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in Hard soil not exceeding 1.5m in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavagtion with lead upto 50m. after breaking of clods complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

174.72

-

82371.74

... More
KSRB 2-2.4 : Excavation by manual means for foundation of buildings, water supply & sanitary lines and electrical conduits etc. , either in pits or in trenches 1.50m and above in width, in soft rock /ordinary rock without blasting not exceeding 1.50mtrs in depth including stacking the excavated stuff clear from edges of excavation with lead upto 50mt including cost of explosives, labour, HOM complete as per specifications. specification. No. KBS 2.1Cl2.9.412.1812.19 Excavation in Soft rock without blasting not exceeding 1.5m depth including all lead & lifts, as directed by the Engineer incharges . - Stilt Floor

19.24

-

28707.04

... More
KSRB 2.14-1: Extra for additional lift of 1.5m. or part thereof for excavation In loose / soft or hard soil including cost of materials, labour complete as per specifications. specification. No. KBS including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

843.48

-

17713.08

... More
KSRB 2.14-2: Extra for additional lift of 1.5m. or part thereof for excavation In soft or hard rock including cost of materials, labour complete as per specifications. in soft or hard rock including all lead & lifts, as directed by the Engineer incharges . - Stilt Floor

1294

-

47554.5

... More
KSRB-3.2: Providing and injecting chemical emulsion for Pre- constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits, with chloropyriphos emulsifiable concentrates of 20% concentration, including cost of chemical, diluting in water to one percent concentration, labour, HOM of equipments, complete as per specifications. Plinth area of the building at ground floor only shall be measured including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

2213.2

-

246329.16

... More
KSRB 4-1.2 : Providing and laying in position plain cement concrete of mix 1:3:6 with OPC cement @ 220kgs, with 40mm and down size graded granite metal coarse aggregates @0.892cum and fine aggregates @ 0.465cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

63.3

-

357727.92

... More
KSRB 4-1.6 ; Providing and laying in position plain cement concrete of mix 1:2:4 with cement @ 240kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.878 cum and fine aggregtes @ 0.53cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

586.76

-

3471958.67

... More
do- Terrace Floor

126.8

-

782250.76

... More
KSRB 4.2.1 : Providing and laying in position reinforced cement concrete of Design mix M25 with OPC cement @ 340kgs, with 20mm and down size graded granite metal coarse aggregates @0.70 cum and fine aggregtes @ 0.47cum, with super plasticisers @ 3 liters confirming to IS 9103-1999 reafirmed-2008 at machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, walls (any thickness) including attached pilasters, columnspillars, posts, struts, buttresses, bed blocks, anchor blocks & plinths etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No KBS 4.1, 4.6 including all lead & lifts, as directed by the Engineer incharges. Stilt Floor

1783.1

-

11262362.73

... More
do- ground floor

102.55

-

654183.88

... More
do- First Floor

98.01

-

631397.08

... More
do- Second Floor

87.48

-

569072.27

... More
KSRB 4-6.1 : Providing and removing centering, shuttering, strutting,propping etc., and removal of form work for foundations, footings, bases of columns for mass concrete including cost of all materials, labour complete as per specificaitons including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

985.34

-

263824.79

... More
KSRB 4-6.5 : Providing and removing centering, shuttering, strutting,propping etc., for columns, pillars, piers, abutments, post and struts,square / rectangular / polygon in plan including cost of all materials,labour complete as per specificaiton.Specification No. KBS 4.6.2 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

2758.12

-

1320587.86

... More
do- Ground Floor

816.48

-

390930.62

... More
do- First Floor

775.44

-

371280.67

... More
do- Second Floor

747.36

-

357835.97

... More
do- Terrace Floor

292.32

-

139962.82

... More
KSRB 4-6.6 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for columns, pillars, piers, post and struts, circular or curved in plan including cost of all materials, labour complete as per specificaiton including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

35.78

-

32872.88

... More
KSRB 5.2-3 : Providing and constructing granite / trap / basalt size stone masonry in foundation with cement mortar 1:6, uncoursed not less than 20 cms high, bond stones at 2m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.13 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

201.39

-

774989

... More
KSRB 5.2-3 : Providing and constructing granite / trap / basalt size stone masonry in foundation with cement mortar 1:6, stone hammerd dressed in courses not less than 20 cms high, bond stones at 2m. apart in each course including cost of materials, labour, curing complete as per specifications. KBS 5.1.13 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

71.32

-

362912.53

... More
KSRB 5.3-3 : Providing and constructing granite / trap / basalt size stone masonry in basement with cement mortar 1:6, edges of stones chistle dressed in courses not less than 15 cms high, bond stones at 2m. apart in each course including cost of materials, labour, curing KBS 5.1.13 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

30.06

-

183829.22

... More
KSRB 2.3 : Filling available excavated earth ( excluding rock ) in sides of foundations upto plinth in layers not exceeding 20 cms. in depth,compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as per specifications. Specification. No. KBS 2.9 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

3006.21

-

634460.62

... More
KSRB 4-6.4 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for vertical surface such as walls at any thickness, including attached pilasters, buttresses, plinth cills and string courses cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

1661.61

-

622854.51

... More
KSRB 4-6.7 :Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for sides and soffits of beams, beam haunchings, cantilever girders, bressumers and lintels not exceeding 1m in depth including cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

1587.73

-

486798.02

... More
do- Ground Floor

1596.97

-

489631

... More
do- First Floor

1599.91

-

490532.41

... More
do- Second Floor

1562.36

-

479019.58

... More
do- Terrace Floor

117.18

-

35927.39

... More
KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintles, and beams retaining walls, return walls, walls (any thickness) including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 including all lead & lifts, as directed by the Engineer incharges . - Stilt Floor

46.57

-

297752.75

... More
do- Ground Floor

6.82

-

44034.42

... More
do- First Floor

7.87

-

51309.72

... More
do- Second Floor

7.65

-

50357.35

... More
do- Terrace Floor

61.53

-

408907.46

... More
Providing and casting reinforced cement concrete racks with design mix M20, granite or trap jelly 12mm and down size 5 cms thick and below with reinforcements of 6mm dia MS bars at 15 cms. Centre to centre for main reinforcement and at 30cms centre to centre for distribution including supports wherever necessary with burnt brick in CM 1:4 including centring, form work, curing etc., complete (inclusive of cost of steel and fabrication charges) including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

26.4

-

27359.64

... More
do- Ground Floor

27.9

-

28914.16

... More
do- First Floor

18

-

18654.3

... More
do- Second Floor

54

-

55962.9

... More
KSRB 4-6.7 :Providing and removing centering, shuttering, strutting,propping etc., and removal of form work for flat surface such as suspended floors, roofs, landings, baconies and likes thickness upto 200mm including cost of all materials, labour complete as per specificaitons for heights 0 to 5mts Specification No. KBS 4.6.2 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

1551.39

-

645067.96

... More
do- Ground Floor

1246.58

-

518327.96

... More
do- First Floor

1158.44

-

481679.35

... More
do- Second Floor

1162.19

-

483238.6

... More
do- Terrace Floor

58.4

-

24282.72

... More
KSRB 4-6.9 :Providing and removing centering, shuttering, strutting, propping etc., for edges of slabs and breaks in floor, cills, plinth including cost of all materials, labour complete as per specificaiton. Specification No. KBS 4.6.2 Centering for sides of slabs including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

204.32

-

154894.99

... More
do- Ground Floor

72.88

-

55250.33

... More
do- First Floor

80

-

60648

... More
do- Second Floor

83

-

62922.3

... More
do- Terrace Floor

49.39

-

37442.56

... More
KSRB 4-6.11 :Providing and removing centering, shuttering, strutting,propping etc., and removal of form work for Stairs (excluding landing)except spiral staircase including cost of all materials, labour complete as per specificaiton.Specification No. KBS 4.6.2 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

36.6

-

19253.43

... More
do- Ground Floor

56.07

-

29495.62

... More
do- First Floor

74

-

38927.7

... More
do- Second Floor

73.31

-

38564.73

... More
KSRB 4-5 : Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixing chicken mesh for drop chajja, facia, backing to cupboards including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specifications.Specification No. KBS including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

165.35

-

185076.25

... More
do- Ground Floor

83.81

-

94248.54

... More
do- First Floor

112.61

-

127226.78

... More
do- Second Floor

127.01

-

144162.7

... More
KSRB 4.9.2: Providing TMT steel reinforcement for R.C.C. work including straightening, cutting, bending, hooking, placing in position, lapping and/ or welding wherever required, tying with binding wire and anchoring to the adjoining members where ever neccessary complete as per design ( Laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specification No KBS 4.6.3 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

273.68

-

22309296.14

... More
do- Ground Floor

76.96

-

6273470.59

... More
do- First Floor

72.59

-

5917245.71

... More
do- Second Floor

69.21

-

5641721.67

... More
do- Terrace Floor

11.22

-

914609.41

... More
KSRB 6-1.3 : Providing and constructing burnt brick masonry for basement and superstructure with approved quality of non-modular bricks of standard size of class designation 3.5 with cement mortar 1:6 including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 including all lead & lifts, as directed by the Engineer incharges. Stilt Floor

12.93

-

82173.12

... More
do- Terrace Floor

38.96

-

257417.68

... More
KSRB 6-2.3 : Providing and constructing burnt brick masonry for basement and superstructure with approved quality of non-modular bricks of standard size of class designation 5.0N with cement mortar 1:6 including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 including all lead & lifts, as directed by the Engineer incharges. Stilt Floor

142.22

-

1009268.5

... More
do- Ground Floor

146.84

-

1051305.39

... More
do- First Floor

222.05

-

1603762.79

... More
do- Second Floor

230.33

-

1678076.12

... More
KSRB 6-7.4 :Construction of partition wall 11.2 cms thick with non modular ground moulded burnt bricks of class designation 50 with cement mortar 1:4 inlcuding providing and fixing plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35 mm. 100 mm. wide as per I.S. 2212/1991 at 7.5 m. c to c including cost of materials, labour charges, scaffolding, curing complete as per specifications Specification No. KBS 6.2 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

24.57

-

22965.58

... More
do- Ground Floor

82.94

-

78046.54

... More
do- First Floor

72.77

-

68935.02

... More
do- Second Floor

75.82

-

72301.95

... More
KSRB 9.4-1 : Providing wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, HOM of machineries complete as per specifications. Specification No. KBS 9.33 including all lead & lifts, as directed by the Engineer incharges. Stilt Floor

0.1

-

5896.07

... More
KSRB 9.4-4 : Providing wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, HOM of machineries complete as per specifications. Specification No. KBS 9.33 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

1.4

-

78327.48

... More
do- Ground Floor

1.82

-

101825.72

... More
do- First Floor

1.94

-

108539.51

... More
do- Second Floor

1.66

-

92874.01

... More
do- Terrace Floor

0.2

-

11189.64

... More
KSRB 9-27.1 : Fixing of door frame in an existing opening including embeeding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

12

-

17249.4

... More
do- Ground Floor

15

-

21624.75

... More
do- First Floor

16

-

23133.6

... More
do- Second Floor

16

-

23200.8

... More
do- Terrace Floor

2

-

2908.5

... More
KSRB 9.5-2 : Providing and fixing in position fully panelled Honne wood shutters for doors, styles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and styles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, HOM of machineries complete as per specifications. ( excluding cost of fixtures) Specification No. KBS 9.34 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

13.97

-

67695.13

... More
do- Ground Floor

21.84

-

105922.91

... More
do- First Floor

24.57

-

119266.47

... More
do- Second Floor

24.57

-

119369.66

... More
Providing and fixing to the existing door frames,factory made single leaf HDF- skin sandwich composite door shutter of 32 mm thickness made out of honeycomb of 26 mm thick and surrounded by good quality properly seasoned wooden reinforcement of size 25mm X 65mm for fixing fixtures such s tower bolts,aldrops,handles etc., and laminated on either sides with 3 mm thick wood grain finish good quality HDF skins,using structural bonding material compatible with honey comb core,wood and HDF skin and the whole assembly is bonded together at high temperature and pressure using 650 tonnage heated compression moulding press .The HDF composite door surface is coated with 2 coatsof high quality premier.The front and back surfaces of door shutter and all 4 sides are painted with 2 coats of high quality paint of any desired colour.The material and process for manufacturing the door shall confirm to RV-TIFAC,composite design centre standard and specification and the door shutter tested in confirmation to IS-4020-1994, including the cost of all material, labour charges,HOM and machineries etc.,complete but excluding the cost of fixtures. HDF shutters including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

14.49

-

21863.24

... More
do- Ground Floor

13.86

-

20912.66

... More
do- First Floor

13.55

-

20444.92

... More
do- Second Floor

13.55

-

20444.92

... More
Supply and fixing of door frame made of hollow extruded PVC Section having dimension of 40x57mm with the wall thickness of 2mm+/-0.2mm duly reinforced with seasoned wood plank at the hinges side. The door frame top 2corners shall be metric cut/ welded including all lead & lifts, as directed by the Engineer incharges. - Ground Floor

42.4

-

11308.08

... More
do- First Floor

42.4

-

11486.16

... More
do- Second Floor

42.4

-

11664.24

... More
PVC DOOR SHUTTER:- Supply and fixing of door shuttersmade of rigid PVC extruded hollow section of 20mm x 200mm with the wall thickness of 1.0mm + /0.1mm equally divided into 4nos with tongue and groove locking arrangements. The shutter frame is made of 58x24 mm with the wall thickness of 1.5mm+/-0.15mm section metricut and joined at 4 corners with 125mmx225mm plastic brackets. The shutter shall be horizontally reinforced with 2nos of 8mm PVC rods. Teak wood battons shall be reinforced inside the door shutter during the fabrication of the door shutter at those points wherever the hardware is fixed on to the door shutter including all lead & lifts, as directed by the Engineer incharges. Ground Floor

15.12

-

28402.16

... More
do- First Floor

15.12

-

28465.67

... More
do- Second Floor

15.12

-

28529.17

... More
KSRRB M300 - Construction of embankment with approved material Gravel/Murrum with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement Table 300- 2 complete as per specifications.(Including cost of gravel / murrum, watering charges & compaction by vibratory roller to 95% of proctors density) MORTH Specification No. 305 Murrum fill up, including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

1225.78

-

585616.4

... More
KSRB 9-26.2 : Providing and fixing in position fully glazed shutters for ventilators side hung or central pivoted with Honne wood styles and rails of 25mm. thick, 50mm wide and central divider of 25mm. wide, 3mm thick reeded glass fixed with wooden beading of size 10mm wide flushed to the thickness of the frame including cost of materials, labour charges, HOM of machineries complete as per specifications. ( excluding cost of fixtures ) Specification No. KBS 9.34, 9.42 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

3.15

-

8487.04

... More
do- Ground Floor

3.12

-

8419.32

... More
do- First Floor

2.93

-

7918.91

... More
do- Second Floor

3.51

-

9501.22

... More
Providing & fixing of glazed 3 Track - 2 Panel Sliding Door With Mesh … made out of multi chambered uPVC sections with TPV gaskets having isolated drainage and reinforced with Galvanized Iron profiles through out the window. The sliding outer frame having a overall size of 108x45 mm with reinforcement of 1 mm thickness, super sash with overall size of 39x75 mm with reinforcement of 1.5 mm thickness, mesh sash of overall size 30x48.5 mm reinforced with 1.5 mm of GI.Glazing bead for fixing of glas shall be of size 20x18mm and coextruded with gasket. Fiber Glass mesh shall be provided in mesh shutter. Window/Door shall be provided with 6 mm plain float glass, standard hardware & multi point locking system of Patio espagnolette. Wall thickness of frame, mullion & sash shall be 2-2.2 mm. uPVC window including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

27

-

160886.25

... More
do- Ground Floor

7.87

-

46895.36

... More
do- First Floor

86.25

-

513942.19

... More
do- Second Floor

86.25

-

513942.19

... More
Providing & of Fixed Louvered Ventilator made out of multi chambered uPVC sections with TPv gaskets having isolated drainage and reinforced with Galvanized Iron profiles through out the windown. The outer frame having a overall size of 60x55mm with reinforcement of 1 mm thickness and Mullion with overall size of 74x60mm with reinforcement of 1 mm thickness. Ventilator shall be provided with 4.5 mm Pin Head glass, standard hardware, Wall thickness of frame Mullion shall be 2-2.2 mm. uPVC Ventilators, including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

13.8

-

65784.6

... More
do- Ground Floor

18.13

-

86425.71

... More
do- First Floor

16.33

-

77845.11

... More
do- Second Floor

16.33

-

77845.11

... More
KSRB 7.10 : Providing and fixing in position aluminium windows and ventilators as per approved drawings with sliding shutters using three track window frame section of size 61.85x31.75mm. with 1.2mm thick, bottom section weight 0.695 kg/m, sides and top sections 1.3 mm. thick weight 0.659 kg/m; and shutter comprising top and bottom section of size 40mmx18mm, 1.25mm thick 0.417 kg./m; shutter outer side 40mmx18mm, 1.25mm.thick weight 0.417 kg/m, shutter interlock section 40mmx26.7mm, 1.1mm thick, weight 0.469 kg/m. the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; and providing and fixing 5.5mm. thick plain glass for shutters fitted with rubber beading aluminium sections including cutting to required length, joints mitred subdividing the frame tenonned and rivetted in the assembled frame stiffened with end clips at corners angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be with necessary steel screws, raul plugs, or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar, aluminium sections Aluminium windows including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

8.24

-

38700.4

... More
Providing and fixing for flooring 20mm thick gang saw water cut telephonic black granite in CM 1:4 proportion with a coat of rough plastering using CM 1:4, cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

52.9

-

132863.64

... More
do- Ground Floor

109.02

-

274043.57

... More
do- First Floor

105.5

-

265416.9

... More
do- Second Floor

105.5

-

265638.45

... More
Providing full nosing for 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification including all lead & lifts, as directed by the Engineer incharges. Stilt Floor

471.2

-

133585.2

... More
do- Ground Floor

872.16

-

249088.9

... More
do- First Floor

421.98

-

121403.65

... More
do- Second Floor

421.98

-

122289.8

... More
KSRB 7.9 : Providing and fixing M.S.grill work for windows and ventilators weighing 21kg/sqm using M.S. flats, or M.S. square rods, or combination of M.S. flats and square rods as per approved design, drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer, cost of materials, fixtures, labour and HOM of machinery complete as per specifications. Specification No. KBS 7.12 Grill work for windows and ventilators including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

1970.4

-

196547.4

... More
do- Ground Floor

2943.15

-

312121.06

... More
do- First Floor

3076.98

-

345698.7

... More
do- Second Floor

3076.98

-

365083.68

... More
do- Terrace Floor

798

-

99710.1

... More
Providing and fixing Stainless steel staircase raling as per Chief Architect Drawing No. 11520/ HRSC with hand rail 50mm dia 16 guage hollow pipe welded to vertical hollow 50mm dia pipe of 16 guage, stainless steel vertical pipe spaced at 1.20m regular intervals, and 5 Nos of 25mm dia. Stainless steel hollow horizontal pipe are welded to vertical 50mm dia hollow pipe. The entire assembly is fixed to staircase concrete by using expansion bolts by drilling concrete etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc., complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

33.96

-

214696.82

... More
do- Ground Floor

24.12

-

152639.8

... More
do- First Floor

24.12

-

152791.76

... More
do- Second Floor

24.12

-

152943.71

... More
KSRB 15.8.1 Providing and fixing plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications.Length of mesh only be measured for payment including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

1467.14

-

40052.92

... More
do- Ground Floor

1714.21

-

46797.93

... More
do- First Floor

1706.52

-

46588

... More
do- Second Floor

1740.39

-

47512.65

... More
do- Terrace Floor

141.44

-

3861.31

... More
KSRB15-3.5 : Providing 15mm thick cement plaster in single coat with cement mortar 1:4, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications Interior Plaster in 1:4 - 15 mm Thick including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

1429.42

-

334341.34

... More
do- Ground Floor

2221.66

-

533642.73

... More
do- First Floor

2408

-

593572

... More
do- Second Floor

2583.73

-

653166.94

... More
do- Terrace Floor

200.43

-

51931.41

... More
KSRB15-3-13 : Providing 12mm thick cement plaster in single coat with cement mortar 1:3, to ceiling including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as perspecifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

2913.1

-

724895.8

... More
do- Ground Floor

2572.05

-

640028.92

... More
do- First Floor

2478

-

616625.52

... More
do- Second Floor

2390.03

-

594735.07

... More
do- Terrace Floor

168.74

-

41989.26

... More
KSRB15-3.8 : Providing 18mm thick cement plaster in single coat with cement mortar 1:4 to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

279.31

-

77262.73

... More
do- Ground Floor

442.44

-

127962.5

... More
do- First Floor

507.6

-

153203.83

... More
do- Second Floor

528.48

-

166164.68

... More
do- Terrace Floor

324.11

-

105990.45

... More
Providing & Applying two coats of wall putty to inside plasters walls and ceiling, using white cement putty scraping and levelling the surface using steel blade and preparing the surface even and smooth by using different grade sand papers, including cost of all materials, labour and scaffolding etc, complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

4251.08

-

348163.45

... More
do- Ground Floor

4793.71

-

392604.85

... More
do- First Floor

4886

-

400163.4

... More
do- Second Floor

4973.76

-

407350.94

... More
do- Terrace Floor

369.17

-

30235.02

... More
Providing and fixing for flooring 20mm thick gang saw water cut sadarahalli grey granite in CM 1:4 proportion cut to required shape, pattern with paper joints, finished with cement morter using white cement and color pigment to match the color of slab making through jointing with sealant grooves in joints including cost of curing including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

313

-

672417.9

... More
do- Ground Floor

599

-

1288089.6

... More
do- First Floor

580.57

-

1249676.92

... More
do- Second Floor

580.57

-

1250896.12

... More
Providing and fixing skirting of 300mm high using prepolished water cut/gang saw of 19mm thick grey granite 0.5mm wide chamfered width and depth and fixing in CM 1:4 of 20mm thick after chipping the walls etc., complete.” Grey Granite Skirting including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

134.63

-

107152.02

... More
do- First Floor

257.58

-

206089.76

... More
do- Second Floor

257.58

-

206630.68

... More
Providing and laying flooring for corridors/lobbies using combination of pre polished 19 mm thick water cut/gang saw Grey Granite, Black Granite, and strips of 50mm wide pre flamed grey granite using pre polished grey granite 19mm thick 76%, Pre polished black granite 19mm thick @ 2% and preflamed 19mm thick grey granite @22% over existing cement concrete bed in CM 1:4 average 20mm thick pointed with white cement/colour pigment etc., complete. - using 19mm thick granite width not less than 1200mm including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

27

-

74248.65

... More
do- Ground Floor

23.19

-

63820.04

... More
do- First Floor

66

-

181773.9

... More
do- Second Floor

66

-

181912.5

... More
Providing and fixing Vitrified glazed tiles of approved make, quality & colour of size 600 x 600 x 10mm thick fixed on bed of 12mm thick cement mortar for flooring, skirting and jointed with neat cement slurry mixed with pigment to mach shade of tiles, including providing spacers at required interval and removing stains, including cost of all mateirals, mortar, labour, etc , Complete as per specification including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

212.14

-

217178.32

... More
do- Ground Floor

572.28

-

587073.44

... More
do- First Floor

606

-

622937.7

... More
do- Second Floor

599.91

-

617937.3

... More
KSRB 14. 14-5 : Providing Ceramic tiles of approved make, shade and size for flooring, treads of steps and landings laid on a bed of 12mm thick, cement mortar 1:3 mix flush pointing with white cement using colour pigment, including cost of materials, labour, curing, complete as per specifications. Specification No KBS of size 300 x 300mm including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

13.33

-

16968.96

... More
do- Ground Floor

60.86

-

77601.98

... More
do- First Floor

55

-

70245.45

... More
do- Second Floor

65.36

-

83614.39

... More
KSRB 14-17.1 : Providing skirting, dado, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over rough plaster surface ( excluding cost of rough plastered surface which should be measured and paid separately) using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Specification No.KBS 14.16, 14.17 Ceramic Dado including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

23.12

-

28406.39

... More
do- Ground Floor

195

-

239996.25

... More
do- First Floor

156.13

-

192484.87

... More
do Second Floor

195.79

-

241790.86

... More
KSRB15-5.1 : Providing rough cement plastering 15mm thick in single coat with cement mortar 1:4, to brick masonry for base of dadooing works with sand of approved quality, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

29.12

-

6325.45

... More
do- Ground Floor

195

-

43586.4

... More
do- First Floor

156.13

-

35881.8

... More
do- Second Floor

195.79

-

46229.93

... More
KSRB 15-15.2 : Providing and applying painting in two coats with plastic emulsion paint of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

4251.08

-

401727.06

... More
do- Ground Floor

4793.71

-

453005.6

... More
do- First Floor

4886

-

461727

... More
do- Second Floor

4973.76

-

470020.32

... More
do- Terrace Floor

369.17

-

34886.56

... More
KSRB 15-15.2 : Extra over for painting two coats with plastic emulsion paint of approved brand and shade on ceiling and / or sloping roof as per specifications Two coats of oil bound distemper for CEILING including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

2874

-

15088.5

... More
do- Ground Floor

2573

-

13508.25

... More
do- First Floor

2478

-

13009.5

... More
do- Second Floor

2391

-

12552.75

... More
do- Terrace Floor

168.74

-

885.88

... More
Providing and finishing external walls in two coats over one coat of 100% acrylic silicon glazed primer with antifungal paint fo topr coat of approved brand and shade to give an even shade after throughly brooming the surface to remove all dirt and loose powdered material, free from mortar drops and other foreign matter cost of materials, labour, complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

1848.84

-

349430.76

... More
do- Ground Floor

442.44

-

87337.66

... More
do- First Floor

507.6

-

104464.08

... More
do- Second Floor

528.48

-

113200.42

... More
do- Terrace Floor

324.11

-

72146.89

... More
KSRB 15-18.2 : Providing and applying enamel metal paint two coats( excluding priming coat ) over new steel or other metal surface brushing to give an even shade after cleaning oil, grease, dirt and other foreign matter, including cost of materials, labour, complete as per specifications including all lead & lifts, as directed by the Engineer incharges - Stilt Floor

93.9

-

9366.53

... More
do- Ground Floor

140.15

-

14568.59

... More
do- First Floor

146.52

-

15846.14

... More
do- Second Floor

146.52

-

16461.52

... More
do- Terrace Floor

38

-

4428.9

... More
KSRB 15-17.5 : Applying priming coat over new wood surface and / or wood based surface after preparing the surface after throughly cleaning oil, grease, dirt and foreign matter, sand papering and knotting liquid wood filler, for varnish including cost of materials, labour, complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

52.94

-

2779.35

... More
do- Ground Floor

118.1

-

6200.25

... More
do- First Floor

126.08

-

6619.2

... More
do- Second Floor

112.08

-

5884.2

... More
do- Terrace Floor

10.67

-

560.18

... More
KSRB 15-17.6 : Providing and applying painting two coats ( excluding priming coat ) on new wood surface and / or wood based surface with enamel paint to give an even shade, cleaning the surface of all dirt,dust and foreign matter, sand papering including cost of materials, labour, complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

52.94

-

5391.94

... More
do- Ground Floor

118.1

-

12028.48

... More
do- First Floor

127

-

12934.95

... More
do- Second Floor

113

-

11509.05

... More
do- Terrace Floor

10.67

-

1086.74

... More
KSRB 10-2 : Providing and laying in position yelahanka tiles of size 250 x 250mm of approved quality and make, over a bed of cement mortar 1:3 an average thickness 25mm over weather proof course and pointed with cement mortar 1:3 mix with red oxide including curing cost of materials, labour complete as per specifications. Specification No. KBS including all lead & lifts, as directed by the Engineer incharges. -Stilt Floor

6.54

-

6702.19

... More
KSRB 11-13.1 : Providing and fixing laboratory sink of white glazed fire clay of size 600x450x200mm with M.S / C.I brackets, C.P brass chain with rubber plug, 32 mm C.P. brass waste, tap with union, brass stop cock complete, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. KBS 11 including all lead & lifts, as directed by the Engineer incharges. - Ground Floor

1

-

3736.95

... More
KSRB 11-14.3 : Providing and fixing stainless steel kitchen sink of size 400x915mm bowl depth 160mm, with drain board, M.S / C.I brackets, stainless steel plug 40 mm, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Ground Floor

1

-

6776.7

... More
KSRB 14.6-1: Providing and laying heavy duty cobble stones 60mmthick interlock pavers, using cement and course sand for manufactureof blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per sqm over 50mm thick sand bed(average thickness ) and compacting with plate vibrator having 3 tonscompaction force thereby forcing part of sand underneath to come upin between joints, final compaction of paver surface joints into its finallevel, including cost of materials, labour and HOM of machineriescomplete as per specifications.Specification No. KBS including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

1282.65

-

1422202.32

... More
KSRRBM800-9. Painting New Letter and Figures of any Shade with synthetic enamel paint black or any other approved colour to give an even shade complete as per specifications. (“i) Hindi ( Matras commas and the like not to be measured and paid for half letter shall be counted as half) including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

18700

-

19635

... More
KSRB 2.4 Refilling available earth around pipe lines, cables in layers not exceeding 20 cms. in depth,compacting each deposited layer by ramming after watering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

648.49

-

82390.65

... More
KSRB 8.6-5 : Providing and fixing on wall surface 2.5 kg / sq.cm H.D.P.E. rain down water pipes 90 mm outer dia approved make and brand with necessary specials like shoes, bends and offsets fixed with iron clamps, wall plugs, screws, including cost of materials, labour, curing complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

432

-

165564

... More
do- Terrace Floor

160

-

61320

... More
KSRB13-6.1-2 : Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

126

-

25137

... More
KSRB13-6.3-5 : Providing and fixing in position brass gate valve withC.I wheel of approved quality ( screwed end ) ___ mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications.Specification No KBS 13.2.6/13.3 Brass Gate Valve- 25mm Dia including all lead & lifts, as directed by the Engineer incharges . - Stilt Floor

16

-

7543.2

... More
Brass Gate Valve- 32mm Dia including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

32

-

27888

... More
Brass Gate Valve- 40mm Dia including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

12

-

13104

... More
Brass Gate Valve- 50mm Dia including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

6

-

10955.7

... More
KSRB13-6.7-1 : Providing and fixing in position chromium plated brass shower rose with 15 or 20mm inlet 100mm dia including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS 13.2.16 / 13.3 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

10

-

7423.5

... More
.KSRB13-10.1 : Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm working pressure (16-32)mm outside diameter chemp plast / Wavin or equivalent make with pipe fittings, wall clips,making good the wall, ceiling and floor, including cost of all materials,specifications..Specification No.KBS 13.2.15.4 / 13.9 -do- 20mm dia UPVC pipe including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

250

-

28087.5

... More
.-do- 25mm dia UPVC pipe including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

400

-

49560

... More
.-do- 32mm dia UPVC pipe including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

30

-

4063.5

... More
KSRB 13-11.1 : Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.(For 1000 litre capacity) Specification No.KBS 13.22 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

12

-

86032.8

... More
.Providing and fixing Chlorinated Poly Vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete. (Concealed work including cutting chases and making good the walls etc.) - -Do- 15mm nominal OD pipes (Concealed CPVC) including all lead & lifts, as directed by the Engineer incharges. Stilt Floor

80

-

17304

... More
.-Do- 20mm nominal OD pipes (CPVC) including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

220

-

54285

... More
.-Do- 25mm nominal OD pipes (CPVC) including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

160

-

30072

... More
.-Do- 32mm nominal OD pipes (CPVC) including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

608

-

144278.4

... More
.-Do- 40mm nominal OD pipes (CPVC) including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

260

-

79716

... More
.-Do- 50mm nominal OD pipes (CPVC) including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

200

-

90720

... More
Drilling holes of 2.50 cms dia (roof/chajja/stone). in slabs upto 7.50 cms thick including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

48

-

6602.4

... More
Wall bores in Brick masonry upto 45 cm thick including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

96

-

12700.8

... More
12.2 KSRB 11-2 : Providing and fixing white vitreous china clay, water closet Orissa pattern of size 580 x 440mm with integral type footrests, 100mm S or P trap, 10 litre low level, P.V.C flushing cistern ( all are approved make ) with fittings, C.I / M.S brackets, 32 mm diameter flush pipe fittings and clamps, overflow arrangements with special and 25mm mosquito proof coupling of approved design, painting of fittings and brackets, cutting and making good the wall and floor wherever required,including cost of materials, labour complete as per specifications.Specification No. KBS 11 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

7

-

31046.4

... More
KSRB 11-6 : Providing and fixing white vitreous china clay, water closet European type ( Pedestal type, S-trap ) with black solid plastic seat and lid, C.P brass hinges, rubber buffers. 10 litre white glazed / vitreous china clay low level, flushing cistern ( all are approved make ) with fittings, C.I / M.S brackets, 40mm diameter flush bend with fittings and clamps, overflow arrangements with specials and 25mm mosquito proof coupling of approved design, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

16

-

80757.6

... More
KSRB 11-11.4 : Providing and fixing white vitreous china clay, flat back wash basinsize 550x400mm with a single 15mm C.P brass pillar tap with C.I / M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of fittings and brackets, cutting and making good the wall and floor wherever required including cost of materials,labour,complete as per specifications.Specification No. KBS 11 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

27

-

85645.35

... More
KSRB 11-9.3 : Providing and fixing white vitreous china clay, flat back or half stall urinal basin of size 580x380x350mm in the range of three with 10 litres P.V.C automatic flushing cistern, C.I / M.S brackets, standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps, C.I. trap with outlet grating and other couplings in C.P brass painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications. Specification No. KBS 11 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

9

-

103808.25

... More
Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures andconveyance of materials to work spot) including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

54

-

14175

... More
Providing stoneware gully trap of approved quality and make fixing in M 15 and plastering with CM 1:3 wherever necessary.( Rate includescost of all materials, fixtures and lead) for 15cms x 10cms including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

25

-

7350

... More
Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00 kgs / sq cm working pressure of 110mm dia ,with pipe fittings, wall clips etc. and making good the wall, ceiling and floor for snaitary pipelines includes cost of all materials, labour charges, HOM of acquirements and testing complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

1280

-

583296

... More
KSRB 12-8.1 : Constructing brick masonry inspection chamber455x610mm, and 450mm depth, ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation50 in cement mortar 1:5, C.I cover with frame (light duty) 455x610mm internal dimensions total weight of cover with frame to be not less than 38 kgs(weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and downsize granite metal,foundation concrete M5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete asper standard design including cost of materials, labour charges, curingcomplete as per specifications.Specification No. KBS including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

26

-

192847.2

... More
KSRB 11-17-1 : Providing and fixing C.P. brass towel rail 740 mm length, 20 mm dia with C.P brackets, fixed to wooden cleats with C.P. brass screws including cost of materials, labour complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

43

-

33365.85

... More
KSRB 11-15.1 : Providing and fixing 600x450mm bevelLead edge mirror of superior glass with 6mm hard board backing and fixed to wooden cleats with C.P screws, washers, including cost of materials, labour complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

44

-

53453.4

... More
Providing and fixing Angle Iron 40x40x6 mm ( 3.5 kg/m) below the wash basin as firm support as per the drawing and including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

368.38

-

20997.66

... More
Providing and laying plat form using prepolished, water cut / gang saw 40mm thick telephonic Black Granite. laid on existing vertical -supports and fixing in CM 1:3 proportion. Including cutting to required shape, pattern with paper joints, including full rounding for nosing, finished with cement mortar, pointed with colour pigments to match the colour of slab making through jointing with sealant, making holes 25mm x 12mm grooves in joints including all lead & lifts, as directed by the Engineer incharges. (For undercounter Wash basins). - Stilt Floor

17.58

-

65067.97

... More
KSRB 11-9.1 : Providing and fixing white vitreous china clay, flat back or half stall urinal basin of size 580x380x350mm with 5 litres P.V.C automatic flushing cistern, C.I / M.S brackets, standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps C.I dtrap with outlet grating and other couplings in C.P brass, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

3

-

15671.25

... More
KSRB 4.2.7 : Providing and laying in position reinforced cement concrete of design mix M25 with OPC cement @ 340kgs, with 20mm and down size graded granite metal coarse aggregates @0.70cum and fine aggregtes @ 0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs, staircase, lintels and beams retaining walls, return walls, walls (any thickness) including attached pilasters, columns, lintles, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

14.18

-

93032.43

... More
do- Ground Floor

420.92

-

2788098.31

... More
do- First Floor

405

-

2708162.1

... More
do- Second Floor

393

-

2652679.26

... More
KSRB 4.2.10 : Providing and laying in position reinforced cement concrete of design mix M-20 with OPC cement @ 24Kgs, with 12mm and down size graded granite metal coarse aggregate @ 0.5175Cum and fine fine aggregates @ 0.345cum with superplastisiser @ 0.225 lts machine mixed, well compacted for plain chajja of 7.5cms average thickness, upto ground floor level, including cost of all materials, labour, HOM of machinery, finishing, curing, complete as per specifications. Specification No KBS 4.1,4.6 including all lead & lifts, as directed by the Engineer incharges. Stilt Floor

9

-

4300.11

... More
do- Ground Floor

37.62

-

18171.96

... More
do- First Floor

37.44

-

18281.58

... More
do- Second Floor

39.78

-

19633.02

... More
do- Terrace Floor

16.32

-

8140.42

... More
KSRB 4-6.10: Providing and removing centering, shuttering strutting propping etc for chajjas, corbels etc, including edges including cost of all materials, labour complete as per specification. Specification No KBS 4.6.2 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

9.81

-

3296.16

... More
do- Ground Floor

131.67

-

44241.12

... More
do- First Floor

121.68

-

40884.48

... More
do- Second Floor

129.29

-

43441.44

... More
do- Terrace Floor

19.27

-

6474.72

... More
KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C.chajja with plastering ( labour charges only ) as per specifications.Specification No. KBS including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

17.2

-

595.98

... More
do- Ground Floor

92.7

-

3212.06

... More
do- First Floor

91.2

-

3160.08

... More
do- Second Floor

98.7

-

3419.96

... More
do- Terrace Floor

36.8

-

1275.12

... More
Lift charges for steel of all diameters for additional floors over ground floor per floor height of 3.5 m or part thereof cost of labour complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Ground Floor

76.96

-

60444.38

... More
do- First Floor

72.59

-

57012.19

... More
do- Second Floor

69.21

-

54357.53

... More
do- Terrace Floor

11.22

-

8812.19

... More
Waterproofing of RCC Terrace / podium slab / toilet / utilities / water retaining structure by preparing the surface by chipping and cleaning and Grouting of Honey comb, voids,cracks / construction joints with cement slurry (1kg cement added in 10 ltr of water) added with 100gm of inorganic accelerator, followed by spraying of liquid biological modified alkaline earth silicates @ 0.40 ltr per sqm on whole surface to reduce the micro porosity and allowing it to dry, curing the surface for the silicates to penetrate deeper into the concrete and spraying waterproofing impregnate liquid containing silane and silanol linear copolymer @ 0.50 ltr per sqm and finally applying polymer slurry made out of cross linked acrylic / styrene / butadiene & cement in the ratio of 1:0.1, @0.50kg/sqm on the whole surface, including all labour charges tools and equipments, all complete as per the specification including all lead & lifts, as directed by the Engineer incharges. - Ground Floor

21.58

-

13028.92

... More
do- First Floor

17.5

-

10565.62

... More
do- Second Floor

24.39

-

14725.46

... More
KSRB 8.5: Providing and laying cinder concrete in cement 1:15 (1 cement: 15 cinder of 12.5mm nominal gauge ) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Ground Floor

5.4

-

11175.57

... More
do- First Floor

4.38

-

9064.63

... More
do- Second Floor

6.1

-

12624.26

... More
Providing & Fixing of Mineral Fibre Suspended Ceiling System in the module size of 600x600x19mm with Exposed grid. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 87%, Thermal Conductivity k = 0.052 - 0.057 w/m K,NRC -0.7,Colour White, Fire Performance UK A2 S1, d0, with Anti Microbial coating on the face of the tile, suitable for zone 4 area according to NF S 90-35:2003 with cleanroom class of ISO 5 (Class 100), Decontamination Class of CP10and Bacteriological Cleanliness Class B1 for specific strains and reduction in colony size. Washability properties of 500 wash cycles as per ASTM D-4828 and suitable for Green Building application with Recycled content of 37%. The tile shall be laid on 24mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15 Kgs/Sqm& pull out strength of minimum 100 Kgs. The T Sections should have a Galvanizing of 90 grams per Sqm and need to be installed with Suspension system of approved make including all lead & lifts, as directed by the Engineer incharges. - Ground Floor

179.2

-

467389.44

... More
do- First Floor

123.44

-

321956.21

... More
do- Second Floor

110.65

-

288597.33

... More
Fabricating, supplying & erecting M.S. angular Truss for all spans as per approved design and drawings. The entire truss is anchored suitably by using 4 Nos of M.S. anchor bolts at each support, with base plate and shoe plate.The work includes cutting, straightening, placing in position of M.S angle and wleding wherever necessary, and applying one coat of red oxide primer coat to all the members including cost of all materials, labour charges, & hire charges of machineries for cutting, welding, grinding & erection equipments, etc., complete as per specification including all lead & lifts, as directed by the Engineer incharges. - - Stilt Floor

90

-

12096

... More
KSRB 9-6.2 : Providing and fixing in position fully panelled Honne wood shutters for doors, styles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and styles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, HOM of machineries complete as per specifications. ( excluding cost of fixtures) Specification No. KBS 9.34Door shutters for internal rooms including all lead & lifts, as directed by the Engineer incharges. - Terrace Floor

3.6

-

16707.6

... More
ISOPROOF SEALER Providing waterproof treatment to roof slab using 2 coats of acrylic co polymer elastomeric ISOPROOF sealer & protector. The surface shall be prepared free of tar, dust, fungus, loose particles etc.,The surface shall be applied with basecoat of crystallization liquid and then ISOPROOF, wetting agent and liquid (1:1:6) over the prepared surface. In addition the surface shall be provided with polysulphide/ acrylic sealant to V groves, making haunch at junction of parapet and roof slab and at damaged portion using patching mortar to drain off rain water. Over this one coat of flexible cementatious membrane (FCM), Spreading 2 layers of 40 gsm non woven geotextile membrane as reinforcing material (over FCM) with one primer coat of ISOPROOF & applying second coat of ISOPROOF liquid over the primer coat - conforming to ASTM D 412 - 1992. The work shall be carried out as per the directions of the Engineer in charge. standards & methodology : 1. surface Preparation The surface shall be made free from all dirt, fungus, loose particles by using wire brush. The surface shall be cleaned with solvent like xylene, Toluene, Benzene, dilute hydro chloric acid including all lead & lifts, as directed by the Engineer incharges. - Terrace Floor

1113.54

-

1145832.66

... More
KSRRB M200-11.2.. Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removalof stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

0.17

-

18457.97

... More
KSRRB M400-19. Construction of Median and island with Soil taken from Borrow Areas. Construction of Median and island above road level with approved material deposited from borrowpits, spread, sloped and compacted as per Clause 400.7 complete as per specifications. MORTH Specification No. 407 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

196.89

-

43207.51

... More
Construction of granular sub-base Grading-Vas Sub-base and drainage layer by providing coarse graded crushed stone aggregates of granite/ trap/basalt material, mixing in a mechanical mix plant at OMC, Carriage of mixed material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the 98% proctor density, complete as per specifications. Clause 401 of MORTH V Revision including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

284.88

-

523467

... More
KSRB 14.6-2 :Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per sqm over 50mm thick sand bed (average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and HOM of machineries complete as per specifications. Specification No. KBS including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

1759.89

-

2056695.45

... More
Providing and fixing Pre cast solid concrete kerb stones made out of CC 1:2:4 and finished with CM 1:3 plastering and finishing cutting etc., complete.-do- of size 450 x 150 x 500 mm including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

1167

-

549026.82

... More
KSRRB 800-1. Painting two coats after filling the surface with synthetic enamel paint in approved shades on new plastered concrete surfaces, with materials, labour complete as per specifications. MORTH Chapter 8 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

2108.8

-

177139.2

... More
KSRB 4.2.2 : Providing and laying in position reinforced cement concrete of design mix M-20 with OPC cement @ 320 Kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.690 cum and fine aggregate @ 0.460 cum, with super plastisiser @ 3 lts confirming to IS9103-1999 Reaffirmed -2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all work in foundation and plinth and ground floor level for roof slabs, staircase, lintels,retaining walls, return walls, walls ( any thickness) including attached plasters, columns, piers,abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets ets, including cost of all materials, labour,HOM of machinery, curing, complete as per specifications. Specification No KBS 4.1,4.6 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

99.73

-

613240.77

... More
Providing and laying plain/reinforced cement concrete for side drains using M20 nominal mix concrete with OPC at 300 kgs. with 20mm and down size granite metal coarse aggregates at 0.69 cum and fine aggregates at 0.43 cum machine mixed, well compacted for walls and bottom including centering, shuttering, cost of materials, HOM of machinery, curing etc., complete excluding cost of steel as per MORTH specification No. 1500, 1700, 2200. including cost of materials, labour, HOM complete as per specifications. Wall & bottom thickness 10cm including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

61.48

-

443356.87

... More
KSRRB M2100- Excavation in Ordinary Soil Earth work in excavation for foundation of structures as per drawing and technical specifications, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material complete as per specifications I. Ordinary soil - A . Manual Means (i) Depth upto 3m MORTH Specification No. 304 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

409.01

-

131157.24

... More
KSRRB M2200-5.1 Providing and laying cement concrete of mix 1:2:4 with OPC @ 240kgs, with 40mm and down size graded granite metal coarse aggregates @0.63cum and fine aggregates @ 0.42cum including cost of materials, labour, HOM curing, form works, scaffolding and centering complete as per MORTH Section : 2200 & IS 456 a) upto 5mtr height including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

28.7

-

169491.29

... More
K8RRB M2200-5.9. Providing and laying Design mix M20 with OPC @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @31ts confirming to 189103-1999 Reaffirmed-2008 including cost of materials, labour, HOM curing, form works, scaffolding and centering complete as per specifications. - i) Upto 5 m height including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

213.82

-

1207914.08

... More
KSRRB M2300-14. Providing T M. T steel reinforcement for R.C.C. work including straightening, cutting, bending, hooking, placing in position, lapping and/or welding wherever required tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design (laps, hooks and wastage shall not be measured and paid) including cost of materials, labour, HOM complete as per specifications. MORTH Specification No. 1600 & 2200 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

19.69

-

1569814.79

... More
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) 0 to 50m Digging bore hole for twoincluding all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

100

-

36435

... More
Sinking borewells sinking borewell of 165 mm dia clear using super fast hydrallic rig of capacity 250 PSIG & above 900 CMC & above in all strata including over burden up to 20m fixing of casing pipes,collars and cap with necessary cutting,treading and welding including transportation of rig and supporting vehicle,crew charges and cost of consumables etc., complete including yeild testing at the final depth with a minimum working of compresor for one hour (excluding cost of casing pipes,collars,cap erc.,) 50.0 0mts to 100.00 mts(PRED SR 2011-12 Dharwad Circle) 50 to 100m Digging bore hole for two including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

100

-

46410

... More
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) 100 to 150m Digging bore hole for two including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

100

-

47880

... More
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) 150 to 200m Digging bore hole for two including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

100

-

56280

... More
Geophysical Investigation of site for sinking Borewell Geophysical Investigation of site for sinking Borewell for supplying drinking water to the habitation either through a hand pump, Mini Water Supply scheme, or Piped Water Supply Scheme by vertical electrical sounding by adopting venner or Schlumberger's method, including reconnaissance survey of geological formation, geophysical investigation of existing ground water in the vicinity, its quality, quantity & acceptability of the users indicating the location of site, recommended depth of casing pipe required to seal the top unconsolidated formation incluing an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instrument and accessories to work site, engaging technical personal and labour required etc., complete including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

2

-

7912.8

... More
Providing, supplying to work site, fixing of Single Phase Submersible Pump Sets of 100mm dia (4inch) suitable for bore well and confirming to IS 8034 specifications, with testing of as per instructions of engineer in-charge of work and latest amendments including all lead & lifts, as directed by the Engineer incharges. 5 HP/3.7KW. - Stilt Floor

2

-

60394

... More
Supply and delivery at site brand new best make outdoor type board consisting of two units ofgalvanized mild steel tubes heavy class (C-Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI mark suitable for up to 6 Hp pumps including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

2

-

19034

... More
Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments 50mm Size including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

4

-

4760

... More
Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

4

-

1800

... More
Supplying,fixing and wiring earth electrodes for ground conduit IC cutouts and other equipments on the meter board using 40mm dia 2.9 mm thick GI pipes 2.5m long burried in pit,the pit should be filled with equal proportion of charcoal and salt 150mm alround the pipe to complete depth.The connection from the pipe to the conduit etc,, is to be established through GI wire of size as per clause 7.3.3 of IS 732 using 12 mm dia bolts,nuts,washers and checknuts etc the pipes shall have 16 through holes of 12 mm dia all as per direction of PMC/EIC including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

2

-

2050

... More
Supply and inserting Casing pipes as per SPD specification ISI Mark 170 mm dia 4.85 mm thickness ERW "B" class ISI 1239/1900 IS 554/1985 including cutting threading installation,transportation providing well cap,reuired collars (required well cap,required collars (required for 175 mm borewell)all as per direction of PMC/EIC including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

40

-

20916

... More
Supply and delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SSStuds & Nuts,Screw Clips &water proof Insulation Tape etc complete with ISI mark including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

2

-

8662.5

... More
Labour charges for Erection of outdoor type panel board and meter board units with all necessary materials and labour tools and equipments including providing cement concrete foundation bed etc., complete. as per specifications, with testing of as per instructions of engineer in-charge of work including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

2

-

2396

... More
Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts andother equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

2

-

7266

... More
Supplying and fixing LT cable of size 4 x 25 Sqm suitable for centrifugal pump sets with ISI mark and its latest amendments including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

50

-

14850

... More
Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply on Turnkey/EPC Basis as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly before procurement) - 250 LPH (Annexure-E) including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

3

-

589050

... More
KSRB15-3.10 : Providing 20mm thick cement plaster in single coat with cement mortar 1:4, to stone masonry & concrete surface including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

136.55

-

39239.01

... More
KSRB15-4.7 Extra for providing and mixing waterproofing compound in cement plaster for brick masonry work at one kg per bag or in the proportion recommended by the manufacturers, for cement mortar 1:4, 20mm thick cost of materials complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

125

-

1181.25

... More
KSRRB M200-11.1. Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removalof stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness complete as per specifications.II.By Mechanical Means:A. In area of light jungle. MORTH Specification No. 201 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

0.07

-

1361.66

... More
KSRB 2-2.6 : Excavation by manual means for foundation of buildings, culverts, water supply, sanitary lines and electrical conduits either in pits or in trenches 1.5m and above in width, in hard rock by chiselling /or wedging where blasting is prohibitted not exceeding 1.5m. In depth including stacking excavated stuff clear from edges of excavation with lead up to 50 mtr , labour HOM of equipment complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

13.51

-

28966.79

... More
KSRB 4-1.7 : Providing and laying in position plain cement concrete of mix 1:3:6 with OPC cement @ 220kgs, with 20mm and down size graded granite metal coarse aggregates @0.84cum and fine aggregtes @0.56cum, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation,plinth and cills, ncluding cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

27.88

-

161422.69

... More
KSRB 5-14.1 : Providing and constructing load bearing wall with solid concrete blocks having block density not less than 1800kg/m3 having a minimum average compressive strength of 5.00Nmm2 confirming to IS 2185(part-1):2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour charges, scaffolding, curing, hire charges machineries etc, complete as per specifications.Solid Concrete blocks of size 400*200*200mm including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

503.91

-

484338.14

... More
KSRB 7.9 : Providing and fixing M.S.grill work for windows and ventilators using M.S. flats, or M.S. square rods, or combination of M.S. flats and square rods as per approved design, drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer, cost of materials, fixtures, labour and HOM of machinery complete as per specifications. Specification No. KBS 7.12 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

93.15

-

525128.47

... More
KSRB 15.1.1 Providing flush pointing to square rubble, course or uncoursed stone masonry with cement mortar 1:3, 20mm deep, after raking joints to depth of 20mm nicely lining, including cost of materials, labour, curing complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

142

-

21091.26

... More
KSRB15-3.7 : Providing 18mm thick cement plaster in single coat with cement mortar 1:6 to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

1503.83

-

390484.5

... More
Providing and fixing M.S. Gate, as per Chief Architect drawing, using 50mm x 50mm 14 guage M.S. hollow pipe frame work bent to ornamental shape as shown in the drawing and 35mm x 6mm and 16 x 16mm Square rods for verticals alternatively spaced at 4cms c/c in two halves and 40mmx6mm M.S. flats for horizontal member and at the top cast iron spikes are provided at alternate vertical members as shown in the drawing etc., complete. All the steel surface should be thoroughly cleaned free of rust and painted with anti corrosive paint (shop paint) etc., complete. The work includes cost of all materials, labour charges for all items of work, hire charges for welding, cutting and grinding equipment, and electricity charges, with lead and lift, loading and unloading charges, etc., complete as per specifiocation including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

35.4

-

111956.04

... More
KSRB 2.5 : Earthwork excavation ( in deposited soil ) and filling sides of foundation upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with all lead and lift including cost of all labour complete as per specifications FILLING BELOW PLINTH - To be brought from outside including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

14

-

5924.1

... More
Cleaning of office floors, toilet floors, corridors, lobbies, partitions, storage units, furnitures, electrical & electronic equipments, doors, windows, curtains, blinds etc., including cleaning of dust, etc., using suitable bombay broom stick, squezers / wipers/ rubber brushes, mop sticks, coir brushes, bamboo baskets, plastic buckets, trolleys, wiping cloths, carry bags, etc.,removing the debris to the nearest garbage pit complete including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

4.4

-

9.24

... More
KSRB13-8.9 : Providing and fixing to wall, ceiling and floor, low density polyethylene pipes 6.00 kgf/sq.cm working pressure 140mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.1 / 13.9 including all lead & lifts, as directed by the Engineer incharges. Stilt Floor

40

-

23352

... More
KSRB13-8.9 : Providing and fixing to wall, ceiling and floor, low density polyethylene pipes 6.00 kgf/sq.cm working pressure 160mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.1 / 13.9 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

40

-

26336

... More
KSRB 4-6.3 : Providing and removing centering, shuttering, strutting, propping etc., and removal of form work for flat surface such as suspended floors, roofs, landings, balconies and likes, thickness above 200 mm including cost of all materials, labour complete as per Specification. Specification No. KBS 4.6.2 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

4.3

-

1964.02

... More
40 mm Nominal Size Stone Aggregate including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

0.34

-

401.88

... More
20 mm Nominal Size Stone Aggregate including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

0.34

-

414.8

... More
KSRB13-8.9 : Providing and fixing to wall, ceiling and floor, low density polyethylene pipes 6.00 kgf/sq.cm working pressure 110mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.1 / 13.9 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

50

-

23625

... More
KSRB13-7.2-3 : Providing and fixing in position 40mm nominal bore non-return valve vertical type of approved make including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS 13.2.10 / 13.13 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

2

-

1896.4

... More
KSRB13-8.7 : Providing and fixing to wall, ceiling and floor, low density polyethylene pipes 6.00 kgf/sq.cm working pressure 75mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor, including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.2.15.1 / 13.9 including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

30

-

10269

... More
KSRB 4-4.2 : Extra for use of water proofing compound in Cement concrete of mix 1:1.5:3,at one kg of compound per bag of cement. Specification No. KBS, including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

14.18

-

2307.8

... More
KSRB 7.4 : Providing and fixing 1mm thick M.S. sheet garage door with frame and diagonal braces of size 40x40x6 mm angle Iron, using M.S. flats 30x6 mm for diagonal braces and central cross pieces 3.15mm thick M.S. Gusset plates at the junctions and corners, with handles, stoppers and locking arrangements etc., including applying a priming coat of red lead paint cost of materials, labour, HOM of machinery complete as per specifications. 1 double leaf door of size 2.4x2.4m. Specification No. KBS 7.9 / 7.12, including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

1

-

2239.65

... More
KSRB 14.7-3 : Providing and laying flooring 40 mm thick, with an under layer of 30mm thick M-15 cement concrete, using broken granite metal of 12.5mm nominal size and top layer of 10mm thick plaster with cement mortar 1:3, finished with floating coat of neat cement , including cost of materials, labour, curing, complete as per specifications. Specification No. KBS 14.3, including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

4

-

2553.6

... More
KSRB 15-14.1 : Providing and applying two coats with oil bound washable distemper of approved brand and shade on wall surface including priming coat with distemper primer after throughly brooming the surface free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications. including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

52.19

-

6027.94

... More
Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00 kgs/sqcm working pressure with pipe fittings, wall clips etc., and making good the wall, ceiling and floor for sanitary pipelines including cost of all materials, labour charges, HOM of acquirements and testing complete as per specifications. - 160mm dia, including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

40

-

35826

... More
KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded non-modular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4, including all lead & lifts, as directed by the Engineer incharges. - Stilt Floor

2

-

31050.6

... More
Erecting & Fixing in position in position STONE Ornamental Work (with or without RCC Column in/out) having neatly carved as per the design (for Elevation) on all sides, as per chief architect's drawing. The exposed faces of ornamental stone work shall be uniform in colour and texture 3 line chistled dressed with pulmane finish with necessary carvings beading cornices, floral cornices etc., and other faces shall be chistle dressed to have proper joints using necessary jointing material. the thickness of joint shall not be less thafn 6 mm. the stone surface shall be perfect true plane and free from winding and twist. The cost includes all necessaty scaffoldings, lead and lift loading and unloading inclusive keeping in position at site. Fixing erecting with necessaty key joints in stone to take care of any lateral movements by using fixing, lug pins at side/bottom and top with necessary jointing materials etc. complete as per the specifications and directions of engineer in-charge of work for successful completion of work as per cheif architects drawings including all lead & lifts, as directed by the Engineer incharges. - All Floors

950.7

-

46489230

... More
Concealed Conduit System Supplying heavy gauge PVC conduit pipe ........mm dia.......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary 19/20mm dia 2mm thick including all lead & lifts and as directed by the Engineer incharges.

3460

-

138400

... More
Concealed Conduit System Supplying heavy gauge PVC conduit pipe ........mm dia.......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) - a) 25 mm dia 2 mm thick including all lead & lifts and as directed by the Engineer incharges.

3100

-

164300

... More
Concealed Conduit System Supplying heavy gauge PVC conduit pipe ........mm dia.......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary 32 mm dia 2.5 mm thick including all lead & lifts and as directed by the Engineer incharges.

930

-

77190

... More
Supplying heavy gauge PVC conduit pipe ........mm dia.......mm thick with suitable size bends, metal/PVC junction boxes adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick including all lead & lifts and as directed by the Engineer incharges.

1100

-

56100

... More
Supplying heavy gauge PVC conduit pipe ........mm dia.......mm thick with suitable size bends, metal/PVC junction boxes adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick including all lead & lifts and as directed by the Engineer incharges.

1180

-

63720

... More
Supplying heavy gauge PVC conduit pipe ........mm dia.......mm thick with suitable size bends, metal/PVC junction boxes adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32 mm dia 2.5 mm thick including all lead & lifts and as directed by the Engineer incharges.

210

-

17010

... More
Supplying and fixing metal fan box with round hook including all lead & lifts and as directed by the Engineer incharges.

142

-

12070

... More
Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. . Group - A. Short point up to 3Mtr from tapping point to out let via switch including all lead & lifts and as directed by the Engineer incharges.

220

-

44000

... More
Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 1100 V grade, COPPER conductor fleand FRLS PVC insulated, 2x1.5Sqmm cable confirming to GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Group - A. Medium point a above 3 Mtr up to 6Mtr from tapping point to out let via switch including all lead & lifts and as directed by the Engineer incharges.

240

-

66000

... More
Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 1100 V grade, COPPER conductor fleand FRLS PVC insulated, 2x1.5Sqmm cable confirming to GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Group - A. Long point a above 6 Mtr up to 10Mtr from tapping point to out let via switch including all lead & lifts and as directed by the Engineer incharges.

200

-

80000

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper conductor resistance single core wire in open or consealed system of wiring with specified IS- 694:1990 & confirming to GTP of Group - A.1.0sqmm including all lead & lifts and as directed by the Engineer incharges.

1000

-

14000

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper conductor resistance single core wire in open or consealed system of wiring with specified IS- 694:1990 & confirming to GTP of Group - A.2.5sqmm including all lead & lifts and as directed by the Engineer incharges.

8200

-

262400

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper conductor resistance single core wire in open or consealed system of wiring with specified IS- 694:1990 & confirming to GTP of Group - A.4.0sqmm including all lead & lifts and as directed by the Engineer incharges.

3630

-

163350

... More
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper conductor resistance single core wire in open or consealed system of wiring with specified IS- 694:1990 & confirming to GTP of Group - A.6.0sqmm including all lead & lifts and as directed by the Engineer incharges.

1200

-

84000

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall..1-3Way including all lead & lifts and as directed by the Engineer incharges.

348

-

33060

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall4-5Way including all lead & lifts and as directed by the Engineer incharges.

20

-

2100

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall6Way including all lead & lifts and as directed by the Engineer incharges.

62

-

7750

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall8Way including all lead & lifts and as directed by the Engineer incharges.

272

-

39440

... More
Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall10-12Way including all lead & lifts and as directed by the Engineer incharges.

40

-

6600

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box...1 to 3 Module including all lead & lifts and as directed by the Engineer incharges.

348

-

38280

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box4 Module including all lead & lifts and as directed by the Engineer incharges.

20

-

2500

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box6 Module including all lead & lifts and as directed by the Engineer incharges.

62

-

10850

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box8 Module including all lead & lifts and as directed by the Engineer incharges.

272

-

54400

... More
Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box12 Module including all lead & lifts and as directed by the Engineer incharges.

40

-

9200

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps one way Switch including all lead & lifts and as directed by the Engineer incharges.

1100

-

77000

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps Two way Switch including all lead & lifts and as directed by the Engineer incharges.

16

-

1520

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps 3way socket including all lead & lifts and as directed by the Engineer incharges.

360

-

37800

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator including all lead & lifts and as directed by the Engineer incharges.

142

-

41180

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16Amps one way switch including all lead & lifts and as directed by the Engineer incharges.

64

-

7360

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps Bell push including all lead & lifts and as directed by the Engineer incharges.

19

-

1824

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.32Amps DP switch including all lead & lifts and as directed by the Engineer incharges.

124

-

22568

... More
Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16Amps universal socket including all lead & lifts and as directed by the Engineer incharges.

124

-

20088

... More
Supplying & Fixing of 70-150 Watts lamp holder 2 Pin including all lead & lifts and as directed by the Engineer incharges.

102

-

10812

... More
Supplying & fixing retrofit type -PL- LED Lamp .......W LED linear source with CCT 6500 degree K, CRI> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit rotection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.8-9 Watts including all lead & lifts and as directed by the Engineer incharges.

102

-

35700

... More
Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V @ 50/60Hz & Power factor >0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x 2' - 9/10w including all lead & lifts and as directed by the Engineer incharges.

24

-

6000

... More
Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V @ 50/60Hz & Power factor >0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4'- 20/22 w including all lead & lifts and as directed by the Engineer incharges.

363

-

136125

... More
Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI> 70%. efficacy >100 lumen per watt, 120degree beam spread, life> 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 2'x2' / 1' x 4' 34 -36watt including all lead & lifts and as directed by the Engineer incharges.

48

-

249600

... More
Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300mm) including all lead & lifts and as directed by the Engineer incharges.

41

-

86100

... More
Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value ≥ 4.2 CMM / Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200mm) including all lead & lifts and as directed by the Engineer incharges.

142

-

411800

... More
Supplying of on load change over switches 4 poles,AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)200 Amps including all lead & lifts and as directed by the Engineer incharges.

3

-

41100

... More
Supplying of on load change over switches 4 poles,AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)630 Amps including all lead & lifts and as directed by the Engineer incharges.

1

-

33300

... More
Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 40 Amps including all lead & lifts and as directed by the Engineer incharges.

8

-

14720

... More
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 100Amps 25kA. 4P including all lead & lifts and as directed by the Engineer incharges.

7

-

44800

... More
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 250Amps 35kA including all lead & lifts and as directed by the Engineer incharges.

3

-

51300

... More
Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 500-630Amps 50kA including all lead & lifts and as directed by the Engineer incharges.

1

-

28500

... More
Supplying and fixing regular MCCB distribution Panel confirming to IS 8828, on wall / wood board / flush mounting using required clamps, bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440Volts 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/ three phase suitable capacity MCCB/MCB's as outgoings confirming to IS8828. 8Way including all lead & lifts and as directed by the Engineer incharges.

26

-

228800

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32Amps SP including all lead & lifts and as directed by the Engineer incharges.

62

-

26908

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.40 Amps SP including all lead & lifts and as directed by the Engineer incharges.

36

-

25668

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps DP including all lead & lifts and as directed by the Engineer incharges.

38

-

34542

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.40 Amps TPN including all lead & lifts and as directed by the Engineer incharges.

60

-

142440

... More
Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63Amps TPN including all lead & lifts and as directed by the Engineer incharges.

28

-

67116

... More
Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door 8Way SP &N including all lead & lifts and as directed by the Engineer incharges.

6

-

8700

... More
Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door 12Way SP &N including all lead & lifts and as directed by the Engineer incharges.

12

-

21600

... More
1Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board.6 Amps 2 pole including all lead & lifts and as directed by the Engineer incharges.

6

-

18600

... More
Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/ panel board. 63 Amps 4 pole including all lead & lifts and as directed by the Engineer incharges.

7

-

33600

... More
Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board.16-25 Amps 2 pole including all lead & lifts and as directed by the Engineer incharges.

6

-

13800

... More
Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board.63 Amps 4 pole including all lead & lifts and as directed by the Engineer incharges.

7

-

22400

... More
Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG including all lead & lifts and as directed by the Engineer incharges.

390000

-

136500

... More
Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect / disconnect banks, with automatic recognition or with standard programs including all lead & lifts and as directed by the Engineer incharges.

4

-

72000

... More
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complet100Amps 4x30x6mm Aluminium Strips including all lead & lifts and as directed by the Engineer incharges.

9

-

18450

... More
Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complet600Amps 4x75x10mm Aluminium Strips including all lead & lifts and as directed by the Engineer incharges.

4

-

18720

... More
Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy including all lead & lifts and as directed by the Engineer incharges.

4

-

31000

... More
Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound including all lead & lifts and as directed by the Engineer incharges.

12

-

5616

... More
Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter including all lead & lifts and as directed by the Engineer incharges.

1

-

4745

... More
Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C including all lead & lifts and as directed by the Engineer incharges.

12

-

5160

... More
Supplying, fixing and wiring 3 Phase Digital Ammeter / Voltmeter including all lead & lifts and as directed by the Engineer incharges.

4

-

4740

... More
Supplying, fixing and wiring 0 to 1500amps CT operated AC analog type Ammeter without CT including all lead & lifts and as directed by the Engineer incharges.

4

-

1608

... More
Supplying, fixing and wiring 0 to 600Volts 96x96mm AC Voltmeter on existing panel/wood board including all lead & lifts and as directed by the Engineer incharges.

4

-

1508

... More
Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50x50x6mm including all lead & lifts and as directed by the Engineer incharges.

48

-

15840

... More
Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. TP & N 20Amps including all lead & lifts and as directed by the Engineer incharges.

4

-

4120

... More
Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers including all lead & lifts and as directed by the Engineer incharges.

2

-

8060

... More
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-39754 core 16 sqmm including all lead & lifts and as directed by the Engineer incharges.

980

-

147000

... More
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 3.5 core 35 sqmm including all lead & lifts and as directed by the Engineer incharges.

90

-

20250

... More
Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-39753.5 core 240 sqmm (From L.T.Distribution Box To Main Panel) including all lead & lifts and as directed by the Engineer incharges.

120

-

135600

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. In existing trench/duct.6 sqmm to 16 sqmm including all lead & lifts and as directed by the Engineer incharges.

980

-

11642.4

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct. 25 sqmm to 75 sqmm including all lead & lifts and as directed by the Engineer incharges.

90

-

1395

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.In existing trench/duct. 95 sqmm to150Sqmm including all lead & lifts and as directed by the Engineer incharges.

120

-

2520

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.sqmm to 16 sqmm On wall /Structure including all lead & lifts and as directed by the Engineer incharges.

48

-

1440

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.25 sqmm to 75 sqmm On wall /Structure including all lead & lifts and as directed by the Engineer incharges.

48

-

1680

... More
Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.95 sqmm to 150Sqmm On wall /Structure including all lead & lifts and as directed by the Engineer incharges.

100

-

4000

... More
Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7) In soil (ordinary) including all lead & lifts and as directed by the Engineer incharges.

460

-

34960

... More
Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable including all lead & lifts and as directed by the Engineer incharges.

180

-

18000

... More
Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV. 100mm including all lead & lifts and as directed by the Engineer incharges.

9

-

8010

... More
Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV. 225-300Sqmm including all lead & lifts and as directed by the Engineer incharges.

2

-

3560

... More
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only45mm dia including all lead & lifts and as directed by the Engineer incharges.

8

-

1552

... More
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only 50mm dia including all lead & lifts and as directed by the Engineer incharges.

24

-

6120

... More
Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only 75mm dia including all lead & lifts and as directed by the Engineer incharges.

4

-

1984

... More
Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia including all lead & lifts and as directed by the Engineer incharges.

30

-

89991

... More
Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts including all lead & lifts and as directed by the Engineer incharges.

14

-

58100

... More
Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip including all lead & lifts and as directed by the Engineer incharges.

180

-

13500

... More
Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc 12 SWG GI Wire including all lead & lifts and as directed by the Engineer incharges.

412

-

5768

... More
Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 KVA ON LINE UPS including all lead & lifts and as directed by the Engineer incharges.

3

-

222750

... More
Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 60 / 65 AH capacity including all lead & lifts and as directed by the Engineer incharges.

72

-

540000

... More
Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. 14.7.1 On wall / ceiling / Rafter / Girders including all lead & lifts and as directed by the Engineer incharges.

447

-

49170

... More
Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired including all lead & lifts and as directed by the Engineer incharges.

150

-

39000

... More
Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame including all lead & lifts and as directed by the Engineer incharges.

41

-

26650

... More
Supplying and drawing UTP-CAT 6E LAN cable including all lead & lifts and as directed by the Engineer incharges.

8300

-

240700

... More
Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.2Pair including all lead & lifts and as directed by the Engineer incharges.

4800

-

69600

... More
Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable 20pair including all lead & lifts and as directed by the Engineer incharges.

180

-

27000

... More
Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6 including all lead & lifts and as directed by the Engineer incharges.

120

-

4200

... More
Supplying & Fixing of switch mounting rack with power manager & Cable manager including all lead & lifts and as directed by the Engineer incharges.

3

-

22800

... More
Supplying fixing of Network Switches 48 port 10/100/1000 Switch including all lead & lifts and as directed by the Engineer incharges.

3

-

56100

... More
Supplying fixing of Network Switches 24 port 10/100/1000 Switch including all lead & lifts and as directed by the Engineer incharges.

3

-

20400

... More
Supplying & fixing of I/O socket with back boxSingle I/o including all lead & lifts and as directed by the Engineer incharges.

166

-

54780

... More
Supplying & fixing of I/O socket with back box Double I/o including all lead & lifts and as directed by the Engineer incharges.

30

-

18000

... More
Supplying & Fixing of …Mtrs Cat 6 Patch Cable 2mtr including all lead & lifts and as directed by the Engineer incharges.

136

-

32368

... More
Supplying & Fixing of Patch panel for LAN cabling 48 Port 10/100/1000 patch panel including all lead & lifts and as directed by the Engineer incharges.

3

-

67500

... More
Supplying & Fixing of Patch panel for LAN cabling 24 Port 10/100/1000 patch panel including all lead & lifts and as directed by the Engineer incharges.

3

-

21000

... More
Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination 20 Pair including all lead & lifts and as directed by the Engineer incharges.

3

-

1050

... More
Supplying of…TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 Volts with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit. The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5 star 1.5 ton capacity including all lead & lifts and as directed by the Engineer incharges.

9

-

477000

... More
Supplying of…TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 Volts with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit. The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 1.5 TR Cassette 1 Ph including all lead & lifts and as directed by the Engineer incharges.

9

-

537300

... More
Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support up to 3.0 ton split/cassette type A/C including all lead & lifts and as directed by the Engineer incharges.

18

-

52200

... More
Supplying and installation of insulated refrigerant copper tubing of 5/8`` and 3/8`` with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit. Leak testing oil and gas charging for additional piping length of tube.Split including all lead & lifts and as directed by the Engineer incharges.

12

-

13860

... More
Supplying and installation of insulated refrigerant copper tubing of 5/8`` and 3/8`` with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit. Leak testing oil and gas charging for additional piping length of tube.Cassette including all lead & lifts and as directed by the Engineer incharges.

36

-

57600

... More
Extra for Fabrication supply and fixing of Stand fabricated using slotted angle/L angle of size 6mm x 50mm for mounting out door/indoor A.C. unit./ Batteries including all lead & lifts and as directed by the Engineer incharges.

18

-

39870

... More
Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v in put and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete.4KVA Capacity including all lead & lifts and as directed by the Engineer incharges.

9

-

37620

... More
Providing 2kg CO2 Gas Type Fire Extinugisher Squeeze Grip Type used Unused Mechanism including all lead & lifts and as directed by the Engineer incharges.

12

-

133164

... More
Supplying and fixing of DANGER/NO ADMISSION/NO SMOKING board made out of MS sheet metal with two coats of non corrosive enameled paint including all lead & lifts and as directed by the Engineer incharges.

4

-

300

... More
Supplying of Four Bucket stand with along with buckets including all lead & lifts and as directed by the Engineer incharges.

2

-

2142

... More
Supplying of Handgloves including all lead & lifts and as directed by the Engineer incharges.

4

-

608

... More
Supplying of first aid chart including all lead & lifts and as directed by the Engineer incharges.

4

-

768

... More
Supplying and Installation of Rubber mat 1mtrx1mtr-10mm thick complete including cost of material,labour,HOM complete as er specifications including all lead & lifts and as directed by the Engineer incharges.

4

-

3948

... More
Providing 2-Pole stracture at Tapping Point Using RCC Pole including all lead & lifts and as directed by the Engineer incharges.

1

-

52918

... More
Double Pole TC Set for erection of Transformer on RCC/PSCC 9 Mtr Long Pole as per IS-1977. For 100/300KVA 4/5star rated Transformer on RCC pole-9 Mtr Long,145kg WL-MS including all lead & lifts and as directed by the Engineer incharges.

1

-

17381

... More
RCC Pole - 9 Mtr Long, 145 Kg WL including all lead & lifts and as directed by the Engineer incharges.

5

-

31290

... More
PSCC Pole - 9 Mtr Long, 200 Kg WL including all lead & lifts and as directed by the Engineer incharges.

2

-

7378

... More
11 kV, Horizontal Cross Arm - Galvanised Iron (GI) including all lead & lifts and as directed by the Engineer incharges.

8

-

2664

... More
11 kV, Special 3 Pin Cross Arm - GI including all lead & lifts and as directed by the Engineer incharges.

8

-

6296

... More
Insulator as per IS-1445 for Ceremic, IS-7935 for GI Pin, IEC-61109 for Polymeric11 kV GI Pin for 11 kV Ceramic Shell Insulator including all lead & lifts and as directed by the Engineer incharges.

24

-

1344

... More
DISC Insulator 45 kN Porcelain including all lead & lifts and as directed by the Engineer incharges.

12

-

3612

... More
ACSR Conductor as per IS-398 (Part - 2/1996)Rabbit ACSR including all lead & lifts and as directed by the Engineer incharges.

0.5

-

18248.5

... More
Guy Wire & GI Wire as per IS-2141 8 SWG GI Wire 281008 including all lead & lifts and as directed by the Engineer incharges.

0.6

-

37975.8

... More
Providing cement concrete to Poles and Guy sets with material and labour including necessary curing etc., complete (cost does not include excavation) Base Concreting with CC 1:4: 8 9mtr square Pole (650x650x150mm) including all lead & lifts and as directed by the Engineer incharges.

8

-

2464

... More
Guy concreting with Boulders, Mud & Sand As per Drawing No. BESCOM/GM/CP/7/dt: 24.10.07 including all lead & lifts and as directed by the Engineer incharges.

4

-

696

... More
Providing Coping for Pole with CC 1:2:4 including all lead & lifts and as directed by the Engineer incharges.

8

-

15440

... More
Labour charges for erection of poles Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth including all lead & lifts and as directed by the Engineer incharges.

8

-

6000

... More
LT Distribution Box as per IS-13947 Part-1&2 LT Distribution Box for 250 kVA DTC with MCCB’s (Sheet Metal) including all lead & lifts and as directed by the Engineer incharges.

1

-

17644

... More
Supply, erection, testing and commissioning of ..... KVA 5Star rated Aluminium/Copper wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, marshalling box with wiring, oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM approved. 250 KVA - Copper Wound including all lead & lifts and as directed by the Engineer incharges.

1

-

605000

... More
Supplying erection, testing and commissioning of 11kV Load Break Switch with 4 wire- ( with Neutral) Metering cubicle and connected accessories, hardware's etc. suitable for outdoor type complete as per latest IS standard technical specification. LBS should be approved by ESCOM.Metering cubical with LBS including all lead & lifts and as directed by the Engineer incharges.

1

-

288627

... More
Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip25x6mm including all lead & lifts and as directed by the Engineer incharges.

115

-

13225

... More
Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip600x600x3mm GI Plate including all lead & lifts and as directed by the Engineer incharges.

8

-

6080

... More
HT Cable GROUP A: Supplying and laying of high tension 11KV cable, Dry Curing & Dry Cooling with true triple extrusion, simultaneously through a single common head, 3 core under ground XLPE (E) cable having stranded compact circular aluminium conductor, screened insulated, insulation screened with extruded semiconducting compound in combination with copper tape, core laid up extruded inner sheathed of GI flat strip armoured and overall PVC sheathed with specified IS 7098/11/85 with latest amendments & confirming to the GTP of GROUP-A 3Cx95sqmm including all lead & lifts and as directed by the Engineer incharges.

0.18

-

140871.78

... More
Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint including all lead & lifts and as directed by the Engineer incharges.

432

-

370656

... More
11.1 Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation Alternator: Alternator is suitable for operation at 1500 RPM, 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Engine Starting –The control system supports automatic engine starting, Primary and back up start disconnects are achieved by battery charging alternator feedback or main alternator output frequency. Controller provide configurable time delay of 0-300 secs to start after remote start signal and time delay of 0-600secs prior to shut down after stop signal. Sleep mode increase battery life. Configurable current settings from low to minimize current draw when genset is not working. Engine Protective functions include, Configurable alarm output, Emergency stop: Annunciated whenever an emergency stop signal is received by the control. Low lube oil pressure warning and Shutdown, High engine water temp warning / Shutdown, Low coolant temp warning, Sensor failure indication, Low and high battery voltage warning, Weak battery warning, Fail to start shut down, Cracking lockout: Control will not allow the starter to engage or to crank the running engine. Cyclic cranking: Configurable for the number of starting cycle, (1 to 7) and duration of crank and rest periods. Alternator Protective functions includes, - High and Low AC voltage shut down, Under and Over frequency shutdown / warning, Loss of sensing voltage input shut down. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship, Powder coated for long lasting service life and superior finish, With UV resistant powder coating, can withstand extreme environment, Use of special hardware for longer life, Insulation material meets exacting IS 8183 specifications for better sound attenuation, Flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling point inside the enclosure.250 KVA / 200 kw

1

-

1723600

... More
Supply, Erection, testing and commissioning of AMF panel suitable for .....KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....amps 4 pole contactor for alternator with thermal O/L relay,..... Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facilityAbove 125 KVA upto 250 KVA including all lead & lifts and as directed by the Engineer incharges.

1

-

203200

... More
Fabricating, supplying and erection of …Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/sec for …….Mtrs pole in single section and single joint welded as per IS 9595/IS 10178AWS having dimensions bottom …..mm, top….mm with 3mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended. 3 meters - Top 70mm and bottom 130mm dia including all lead & lifts and as directed by the Engineer incharges.

12

-

64320

... More
Fabricating, supplying and erection of …Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/sec for …….Mtrs pole in single section and single joint welded as per IS 9595/IS 10178AWS having dimensions bottom …..mm, top….mm with 3mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended. 8 meters - Top 70mm and bottom 135mm dia including all lead & lifts and as directed by the Engineer incharges.

12

-

147120

... More
Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 40/50MM dia including all lead & lifts and as directed by the Engineer incharges.

12

-

20268

... More
Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT > 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>130lm/w, nominal CRI >75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts including all lead & lifts and as directed by the Engineer incharges.

12

-

40320

... More
Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT > 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency>130lm/w, nominal CRI >75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Floodlight 200W including all lead & lifts and as directed by the Engineer incharges.

4

-

72000

... More
12.7 Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light output.Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT > 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire > IK08. Power Factor >0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB . LED Efficiency>130lm/w, nominal CRI >75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.LED Post Top Lantern with 25 watts including all lead & lifts and as directed by the Engineer incharges.

12

-

67200

... More
Design, supplying, erecting testing and commissioning of - passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,With Out Machine Room-SS Finish 10 Pass including all lead & lifts and as directed by the Engineer incharges.

1

-

1432000

... More
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. including all lead & lifts and as directed by the Engineer in-charge.(Unit of this item is kWp)

40

-

2442400

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required including all lead & lifts and as directed by the Engineer incharges.

2

-

896

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) including all lead & lifts and as directed by the Engineer incharges.

200

-

20800

... More
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) including all lead & lifts and as directed by the Engineer incharges.

120

-

19560

... More
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required including all lead & lifts and as directed by the Engineer incharges.

6

-

612

... More
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required including all lead & lifts and as directed by the Engineer incharges.

40

-

7040

... More
Supply and Installation of Conventional type, 5 segment 50mm dia hollow copper spike (air termination rod) for lightning protection with copper down rod and necessary fixing hardware as per IS 2309, 1969 including all lead & lifts and as directed by the Engineer incharges.

2

-

5000

... More
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required including all lead & lifts and as directed by the Engineer incharges.

6

-

31848

... More
KSRB 2-2.1 : Earthwork excavation by manual means for foundation of buildings, culverts, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in ordinary soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications. No. KBS 2.1(a) / 2.3.5 including all lead & lifts and as directed by the Engineer incharges.

12.61

-

4335.95

... More
KSRB 4-1.2 : Providing and laying in position plain cement concrete of mix 1:3:6 with OPC cement @ 220kgs, with 40mm and down size graded granite metal coarse aggregates @0.892cum and fine aggregates @ 0.465cum machine mixed, machine mixed, concrete laid in layers not exceeding 15 cms. thick, well compacted, in foundation including cost of all materials, labour, HOM of machinery, curing complete as per specifications. Specification No. KBS 4.1, 4.2 including all lead & lifts and as directed by the Engineer incharges.

5.57

-

35448.04

... More
KSRB 4.2.2 : Providing and laying in position reinforced cement concrete of Design mix M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.460 cum, with super plasticisers @ 3 liters confirming to IS 9103-1999 reafirmed-2008, machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for all works in foundation for footings, pedastals, retaining walls, return walls, walls (any thickness) including attached pilasters, columnspillars, posts, struts, buttresses, bed blocks, anchor blocks & plinths etc., including cost of all materials, labour, HOM of machinery, curing, complete but excluding cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6 including all lead & lifts and as directed by the Engineer incharges.

5.64

-

39246.79

... More
KSRB 6-1.3 : Providing and constructing burnt brick masonry for basement and superstructure with approved quality of non-modular bricks of standard size of class designation 3.5Newton per sqmm with cement mortar1:6 including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. KBS 6.2 including all lead & lifts and as directed by the Engineer incharges.

11.49

-

81751.92

... More
KSRB15-3.8 : Providing 18mm thick cement plaster in single coat with cement mortar 1:4, to brick masonry including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications including all lead & lifts and as directed by the Engineer incharges.

67.94

-

20626.58

... More
Fabrication supplying and erecting M.S. tubular trusses of all spans as per approved drawing & design with prefabricated steel applications using quality material and are durable, reliable and corrosion and abrasion resistant. Welding shall confirm to latest structural welding code. Quality shall be on various parameters like shape, size, design gauge and polish. The entire trusses is anchored in RCC column by using 4 nos of M.S. anchor bolts at each support with 10mm thick base plate and shoe plate. The work includes cutting,traightening,placing in position of M.S. pipes and welding wherever necessary and applying one coat of redoxide primer coat to all the members including cost of all materials, labour charges, and hire charges of machineries for cutting, welding, grinding and erection equipments, with all lead and lift, transportation, letc., complete as per specification including all lead & lifts and as directed by the Engineer incharges.

121

-

16837.15

... More
Providing and installing of pre painted Galvolume iron Trapezoidal profiled sheet of approved make 1060 mm width (1000 mm cover width),28-30 mm crest height with crest distance of 200 mm c/c with 2 ribs at the centre for stiffening. The total coated thickness (TCT) of the sheet will be 0.47 mm +/- 0.02 mm tolerance Zinc-Alu Alloy coating AZ150 gsm as per ASTM 1397/A755-550 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 20-22 microns using self drilling/self tapping screws of 25 mm length, to be fixed over the existing purlins, rafters, channels and trusses including all lead & lifts and as directed by the Engineer incharges.

770

-

681835

... More
KSRB 15-18.1 : Applying red lead ready mix priming coat over new steel or other metal surface including preparing the surface after throughly cleaning oil, grease, dirt and other foreign matter, and scoured with wire brushes, fine steel wool, sand papers including cost of materials, labour, complete as per specifications including all lead & lifts and as directed by the Engineer incharges.

41

-

1933.15

... More
KSRB 15-18.2 : Providing and applying enamel metal paint two coats ( excluding priming coat ) over new steel or other metal surface brushing to give an even shade after cleaning oil, grease, dirt and other foreign matter, including cost of materials, labour, complete as per specifications including all lead & lifts and as directed by the Engineer incharges.

95

-

10378.75

... More
Consolidated Labour Charges For Shifting of Conductor Terminations and all other Fittings existing on the detorated pole while replacing termination poles

4

-

13200



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.