Keladi Shivappa Nayaka University Of Agricultural And Horticultural Sciences Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Keladi Shivappa Nayaka University Of Agricultural And Horticultural Sciences Tender

Works
Civil And Construction
Building Construction
Electrical and Electronics
Electrical Works
Opening Date8 Nov 2024
Closing Date15 Nov 2024
Tender Amount₹ 1,49,06,717.15 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

11554.254

154

1783399.1049

... More
code05 - Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge

671.2

145

97961.64

... More
code06 - Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.19/20mm dia 2mm thick

300

69

20700

... More
code07 - 25mm dia 2mm thick

600

81

48600

... More
code08 - Supplying and flush mounting powder coated/galvanised metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way

20

261

5220

... More
code09 - 10-12Way

20

319

6380

... More
code10 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Moudule

20

284

5680

... More
code11 - 12 Moudule

20

344

6880

... More
code12 - Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVCConduit /casing capping casing capping using 2x1.5Sqmm(Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLSmulti strand PVC insulated copper wire (confirming toIS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for eachoutlet. 2.2.1 Short point up to 3Mtr from tapping point to out let via switch box

10

269

2690

... More
code13 - 2.2.2 Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch box

20

379

7580

... More
code14 - 2.2.3 Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box

30

555

16650

... More
code15 - 2.2.4 Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches

30

677

20310

... More
code16 - Supplying and fixing of modular switch & connectedaccessories on existing modular switch plate as per IS 3854and IS 1293. 3.6.1 6Amps one way.

200

102

20400

... More
code17 - 3.6.3 6Amps 3way socket.

70

171

11970

... More
code18 - 3.6.9 32Amps DP switch

30

326

9780

... More
code19 - 3.6.10 6/16Amps universal socket

30

236

7080

... More
code20 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With low conductor resistance single core cable in open or concealed system of wiring with specified IS 694:1990 & Conforming to GTP of GROUP-A 1.5 sqmm

1200

26

31200

... More
code21 - 2.5 sqmm

600

42

25200

... More
code22 - 4 sqmm

600

63

37800

... More
code23 - 6 sqmm

1200

92

110400

... More
code24 - 10 sqmm

300

167

50100

... More
code25 - Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 11 00 Volts as per IS-694:19904CX4Sq.mm

800

225

180000

... More
code26 - providing and fixing high volume low speed ( HVLS) fan for ceiling , fixing new ceiling fan technology design to circulate more air volume in the facility effeciently and effectively by pulling the air from above the fan pushing in down conical shape to the floor below by rotating at optctimized low speed low power consuption dia 12 feet(3.6m ,no of blade 5, power 1.1KV 3phase supply speed 110 RMP fan wgt 45 kg ( including meterial laobur and fixing charges)

2

180000

360000

... More
code27 - Supplying of ......feet - PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burninghours & 70% lumen maintenance with CRI 80. PowerInput: 220-240V @ 50/60Hz & Power factor 0.9 along withCE approved. 2 years Warranty against any manufacturingdefect working under standard electrical condition.LED light fighting 1x 4' - 36 /40 w

20

1269

25380

... More
code28 - Fixing all types and all capacities fluorescent/false ceiling/spot light/ CFL fittings indoor on the wall /ceiling/rafters/girders using 23/ 0.0076" twin twisted PVC insulated wires, required nos of round blocks and clamps (if required). a) On wa/ceiling/Rafter/Girders

110

122

13420

... More
code29 - Supplying of recess mounting non integral type ........ LED w lumina ire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEOs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEOs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THO less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLI CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 1 'x1' 24watts

30

3692

110760

... More
code30 - LED modular down light 1' x 4', 34-36 watts

30

5898

176940

... More
code31 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and coomplete wiring as required. 6-32Amps SP,

8

415

3320

... More
code32 - 50-63Amps DP

60

1102

66120

... More
code33 - 50-63Amps TPN

30

3088

92640

... More
code34 - Supplying and fixing regular MCB distribution boards on wall / woodboard/flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting etc., complete. II - Double Door, 4 Way SP & N

20

1524

30480

... More
code35 - 12 Way TP &N

2

8735

17470

... More
code36 - Supplying & fixing Chemical earthing for grounding. Conduits, IC cutouts & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achiveing ohmic value less than one ohmUsing 10ft. Copper bonded rod with backfill compound

8

7260

58080

... More
code37 - Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia.(68/1)

6

2999

17998.2

... More
code38 - Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. GI STRIP 25X3mm

100

75

7500

... More
code39 - 25x3mm Copper strip 40x6mm

4

1430

5720

... More
code40 - Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. (Open Execution) 250 Amps

1

15823

15823

... More
code41 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Microprocessed release and Earth Fault as per IS-13947. ( Icu = Ics) Four POLE , 250 Amps 36kA. Group A

1

23545

23545

... More
code42 - Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.

3

9315

27945

... More
code43 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of pecentage leakage current, programable delay/auto/maunal reset facility suitable to mount on DIN rail/ flush mounting on panel board. a) Group A

3

9255

27765

... More
code44 - Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accurecy. With tape wound. a) Group A

3

562

1686

... More
code45 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C. a) Group A

3

515

1545

... More
code46 - Supplying.........amps rated 3phase with neutral bus bar using requiemed capacity electrolyticaluminium strips covered with heat shrinkable couloured PVC sleeve, mounted on phenolic/FRP/DMC insulator whcih are mounted on powder coated 40x6mm M.S.tlat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary botls,nuts and washers etc., complete. b) 400Arnps 4x50x10mm Alluminium Strips

8

4445

35560

... More
code47 - Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Microprocessed release and Earth Fault as per IS-13947. ( Icu = Ics) Four POLE , 125Amps 25kA. Group A

10

10341

103410

... More
code48 - Fabricating supplying and mounting MS box made out ... SWG suitable for floor/wall mounting, fully weatherproof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. b) 16SWG

340000

-

146200

... More
code49 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6mm

10

305

3050

... More
code50 - Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI strip 40x6mm

60

160

9600

... More
code51 - Supplying of 1.1 KV LT UG cable XLPE or Heat resistantPVC insulated, PVC extruded Inner sheath armoured UG LTcable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouringstrip thickness in average +5% andresistivity 14 Ohms/Kms(Max) as per IS-3975 4 core 16 sqmm

300

150

45000

... More
code52 - 3.5core 25 sqmm

180

180

32400

... More
code53 - 3.5 core 150 sqmm

200

720

144000

... More
code54 - Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)

200

76

15200

... More
code55 - Labour charges for laying of 1.1 KV class UG cable when supplied agency in existing trench GI pipe / stoneware pipe / on wall / on pole as required. In exixting trench/duct. 25 sqmm to 75 sqmm

800

15

12400

... More
code56 - Supplying, fixing and wiring Electronic Trivector Meter (ETV)5 to 32/63 Amps three phase 4 wire whole current class-1Accuracy Energy Meter.

1

5705

5705

... More
code57 - Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm

4

7260

29040

... More
code58 - Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source. 90 Watts

6

8860

53160

... More
code59 - Fixing halogen/metal hallide/SVL/IL floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires complete.

6

162

972

... More
code60 - Supplying & fixing...mm dia class A Gi pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on raii/RCC/wail/tubular pole, using suitable clamps, bolts and nuts and wiring using suitable capacity wires etc complete. Using 32mm dia G.I.pipe

6

1295

7770

... More
code61 - Universal Voltage driver to operate wide voltage range from100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABLICPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved I Embossing on the die cast housing/ Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Floodlight 240W

5

22068

110340

... More
code62 - Supply and Installation / Fixing / Provision of Outdoor typeThermoplastic Modular Panel enclosure with transparentPolycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof,dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three PhaseEnergy Meter in suitable base plate and having a provision for Fuse /MCB cut-out with suitable transparent hinged flap opening foroperating MCB along with complete tamper proof SEALING facility. 600 mm x 600 mm x 170 mm

2

12081

24162

... More
code63 - Supplying and fixing of Metal Socket set of 2pole and earth plugs andsocket for incorporating SP and TP MCB (Without MCB). The entireplug and socket shall be mounted in a thermoplastic /powder coatedmetal box & wired CompletelyTP & N (Standard Band as per the Engineer Directions) 30 A

20

1420

28400

... More
code64 - OVING LIGHT CONTROLLER DMX512 Total Channels 1024 MAX Intelligent Fixtures 120 MAX Playback Programs 300 MAX Preset Focus 20 MAX Groups 20 Scene-snapshots 40 Shape-Generator YES LCD Display Screen YES (Chinese/English) Synchronous Trigger Mode Auto1, Auto2, Music Library Format R20 Format USB Port YES Music Control Signal Input Line level input MIC input Power Supply Switch Power Supply AC 100 240V 50 60Hz Power 15W Size 482mm 440mm 108 mm

1

120000

120000

... More
code65 - 12 CH DMX DIMMER PACK Power AC 100-240V, 45---63Hz, 30 4W Output Maximal output is 20A per channel (Please refer to the before installation) Protocol DMX512 Analog Signal Connector XLR 5-pin (Male x1, Female x1), 6p4c phone jack (x2) Dimension DX-1227: 482(W) x 132(H) x 312(D) mm Location DX-1227: 19" 3U Standard rack Weight DX-1227: 13.5 Kg (Standard Band as per the Engineer Directions)

2

80000

160000

... More
code66 - VIDEO MOUNT Equipment Rack Enclosure: Rack Enclosure, Black, Shelves and Blanks, SteelRack Enclosure ColorBlack FeaturesShelves and BlanksFeaturesAdjustable Front and Rear Rails; Reversible Tempered Glass Front DoorFinishPowder CoatedIncludesCastersDoorFansLeveling Feet MaterialSteelMounting LocationFloorOverall Height39 inOverall Width23-5/8 inOverall Depth23-5/8 inOverall Load Capacity1,000 lbRack Units18Manufacturer Part NumberEREN-18BrandVIDEO MOUNT (Standard Band as per the Engineer Directions)

2

25000

50000

... More
code67 - Auditorium Stage 1000W Profile Spot Light (Standard Band as per the Engineer Directions)

12

20000

240000

... More
code68 - Auditorium Stage FOG Spot Light (Standard Band as per the Engineer Directions)

10

18000

180000

... More
code69 - Auditorium Stage Light Halogen Par Can Light (Standard Band as per the Engineer Directions)

12

12000

144000

... More
code70 - Pyle Moving Stage Light - for Professional DJ Show Performance or Dance Party with Rotating RGB Color LED Projector Bulb, Flashing Disco (Standard Band as per the Engineer Directions)

2

38500

77000

... More
code71 - Supply, testing & Commissioning of Line Array Speaker- Frequency Range (-10 dB) 1:57 Hz-20 KHz Frequency Response ( 3dB) 1:75 Hz-20 KHz Coverage Pattern: 100 x 15 nominal, Crossover Modes: Bi- amp / passive, externally switch able Crossover Frequency: 1.2 KHz, Power Rating Passive: 3200W (Continuous / Program / Peak). 12" JBL Speaker HF 2 Nos with Wooden cabinate with stand Make: VRX932 " (Standard Band as per the Engineer Directions)

3

172304

516912

... More
code72 - Supply, testing Commissioning of Sub Woofer Nominal Impedance 8 ohms Power Capacity Continuous Program Peak Passive 3200W Frequency Range 31 hz 220 Hz (-10 dB) Make (Standard Band as per the Engineer Directions)

2

150656

301312

... More
code73 - Array Frame for suspending VRX932LA-1/P, VRX918s/P enclosures. Includes Quick Release Pins, Shackles, Drop Levers Make:, LD Systems (Standard Band as per the Engineer Directions

3

72820

218460

... More
code74 - Two Way Stage Monitor Speaker Frequency Range (-10 dB )48 Hz - 20 KHz Coverage Pattern: 50 x 90 Crossover Frequency: 1.1 KHz Power Rating: Active Full-Range RMS-300W Peak-1200W Make: LD ICOA15A

2

66000

132000

... More
code75 - Delay Speakers At - 18m Dispersion (H x V) - 90 x 50 Load rating (RMS)-250 W Dispersion (H x V)-90 x 50 Peak power-1000 W Frequency response-55 Hz - 20000 Hz Crossover frequency-2000 Hz SPL (1W/1m) 93 dB Max. SPL-123 dB Impedance-8 Ohm(s) Make: LD Systems ICOA 12A (Standard Band as per the Engineer Directions

2

55000

110000

... More
code76 - Loudspeaker management system- with 2 inputs and 6 outputs on XLR connectors, Feedback elimination, 2.7 seconds of alignment and zone delay, compression and limiting functions, Graphic and parametric EQ, Auto EQ Function, Full band pass, crossover and routing configuration, Auto Gain control. Make: Dbx or equivalent 360 DBX (Standard Band as per the Engineer Directions

1

49500

49500

... More
code77 - Gooseneck Microphone (Podium Mic): Professional high quality 21” gooseneck microphone with Base, Electret gooseneck microphones with LED, Supercardioid polar pattern Make: Studiomaster Flex4 (Standard Band as per the Engineer Directions

1

9300

9300

... More
code78 - Cordless Hand held microphone with complete set of transmitter, receiver and microphone with 650-865 MHz frequency range UHF with receiver power Cable. Make: Shure

2

38016

76032

... More
code79 - Microphone Cordless Head Mic - with complete set of transmitter, reciever and microphone with 650-865 MHz frequency range UHF with receiver power Cable. Make: Shure (Standard Band as per the Engineer Directions

3

40000

120000

... More
code80 - Lead Vocals / Live Sound Mice Polar pattern supercardioid, Frequency range 70 Hz to 20 kHz, Sensitivity 2.6 mV / Pa (-52 dBV), Max. SPL 147/156 dB SPL (for 1% / 3%THD), Equivalent noise level 18 dB Make Shure S.M58 with Berenger (Standard Band as per the Engineer Directions

3

10824

32472

... More
code81 - Bass Instruments, Live Sound Type Cardioids Polar pattern 75 to 20,000 Hz, Sensitivity 4 mV / Pa (-48dBV) Max. SPL 144/156 dB SPL (for 1% / 3 % THD) Equivalent noise level 18 dB-A Impendence. Make: Shure S.M 57 (Standard Band as per the Engineer Directions

2

9400

18800

... More
code82 - Sound Mixer with 24-channel stereo, +48v phantom power, XLR inputs and stereo phone jacks, playback inputs and record outputs. frame sizes Up to 40 inputs (including stereo inputs and returns) 18dB/octave high-pass filter 6 aux sends, 4 of them pre/post switchable Group and mix inserts 12-segment LED metering Make: Mackie/Yamaha. (Standard Band as per the Engineer Directions

1

153560

153560

... More
code83 - Speaker Cable: Providing Laying cabling for speakers with 40/36x23/36 cable in conduit including fixing to the walls ceiling boards with guttas redoing the damage portion etc. Complete including testing and commissioning

600

88

52800

... More
code84 - Microphone Cable: Providing Laying cabling for Microphones with 8core Cable with tighter Beading in conduit including fixing to the wall ceiling boards with gutts redoing damage portion With XLR (Standard Band as per the Engineer Directions

500

176

88000

... More
code85 - Interconnecting cables with end connectors Neutrix connecting to DBX, Amplifier, Equalizer, Mixer XLR, Phono Jack, Ear Phone Jack 23 Stand Cable. (Standard Band as per the Engineer Directions

2

25300

50600

... More
code86 - Amplifier Rack: Supplying of M.S Rack with powder coated adjustable self and Amplifier Internal connecting cable with power distribution board and cooling Fan Make: Modular/ Custom (Standard Band as per the Engineer Directions

1

42460

42460

... More
code87 - Supplying of Microphone stand make Model No. DGN of height 92-162cms, base diameter of 23cms, weight of 5.0Kgs of floor stand of floor standing mike stand made by SS type with side tightner including adjustable system (Standard Band as per the Engineer Directions

2

7308

14616

... More
code88 - Supplying of microphone stand make Model No. DGT of height 35-53cms, base diameter of 16cms stand made by SS type with side tightner including adjustable system (Standard Band as per the Engineer Directions

4

3194

12776

... More
code89 - Mike termination box 3Pin XLR Female chassis mount connector with wooden box & top CR Seat plate including XLR whole, Net bolts & anchoring bolts (Standard Band as per the Engineer Directions

2

15730

31460

... More
code90 - Supply, testing & Commissioning of Power Amplifier-Frequency Response (at 1W) 22Hz, Signal to Noise ratio no Weighting 95 dB, THD 0.5%, Power output at 4ohm 3000 per Channel at 80hm 2000 per Channel, Input XLR Connectors, output Connectors, 4 pole & 2 pole Speakon Connectors, with Clip, Power and fault indicators, with internal heat sinks with forced air cooling.Make: Crown 6002 (Standard Band as per the Engineer Directions

2

124608

249216

... More
code91 - DI Box with Unbalanced & balanced input & Balanced Output, Must Have-20dB pad & earth lift switch , Should be able to run either battery & console Phantom power, make : BSS, Behringer (Standard Band as per the Engineer Directions

2

11220

22440

... More
code92 - XLR TO XLR Microphone Cable(15Mtrs) with 2 core cable top ceilded & rubber sleeving , soldring for charsie connectors for both side each 15mtr lenghth including XLR Connectors. (Standard Band as per the Engineer Directions

16

1848

29568

... More
code93 - Novastar Processor VX1000 & VX600

2

120000

240000

... More
code94 - P2 Indoor LED Video Wall. Wall Size :Width: 19.68 FT Height: 9.84 FT Pixels Wide: 2400 Pixels High: 1200Electrical Peak Watts:38880 W Ampere at 230V (max): 169.04 Arequired Processors (min) HD (1920x1080): 4 4K (3840x2160): 1 (Standard Band as per the Engineer Directions

200

7000

1400000

... More
code95 - HDMI Cable 4sets, AUX cable 4Sets, USB Cable 4sets, VGA cable 4Sets, 230V 3 core cable 4Sets, Each cable sets of 50mtrs The each cable passed through PVC 6Kg pressure of 75mm dia pipe of 50 meter length

461.43

300

138429



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.