Karnataka Veterinary Animal And Fisheries Sciences University Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Veterinary Animal And Fisheries Sciences University - KVAFSU Tender

Works
Civil And Construction
Building Construction
Opening Date9 Dec 2024
Closing Date31 Dec 2024
Tender Amount₹ 4,33,73,914.13 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m

114

290

33069.12

... More
code05 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

102

297

30387.84

... More
code06 - Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work

516

95

49123.2

... More
code07 - Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work.

352.5

530

187135.2

... More
code08 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.

124.5

132

16453.92

... More
code09 - Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates

31

6343

196654.08

... More
code10 - Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates

11

6963

76593.44

... More
code11 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (Rate is inclusive of Shuttering) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

77

7096

546416.64

... More
code12 - Shuttering Work for Isolated Footing @8%

45.22

567

25671.394

... More
code13 - Shuttering Work for Pedestals @70%

10.161

4967

50473.95462

... More
code14 - Shuttering Work for Columns Upto Plinth Beam @70%

6.84

4967

33977.1528

... More
code15 - Shuttering Work for Plinth Beam @50%

14.25

3548

50561.28

... More
code16 - Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates

13

7257

94348.8

... More
code17 - Shuttering Work for Wall@ 10%

13

725

9434.88

... More
code18 - Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

5

7096

35481.6

... More
code19 - Shuttering Work of Cement concrete Drain Walls @ 35%

5

2483

12418.55

... More
code20 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Rate is inclusive of Shuttering) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

40

7664

306566.4

... More
code21 - Shuttering Work for Columns @ 70%- Ground Floor

12.5442

5364

67298.504022

... More
code22 - Shuttering Work for Roof Beam, Lintel Beam @ 60%-Ground Floor

14.0589

4598

64649.711061

... More
code23 - Shuttering Work for Sloped Roof Slab @ 70%-Ground Floor

12.795

5364

68644.02345

... More
code24 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Ground Floor

12.08

100191

1210317.4272

... More
code25 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Ground Floor

346

1467

507651.2

... More
code26 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Ground floor

27

1236

33384.96

... More
code27 - Providing and constructing 75mm thick jaali wall using 200x200x75mm clay jaali with cement mortar 1:3 with 12mm deep recessed pointing with CM 1:3 after raking joints to depth of 12mm nicely lining ,including cost of materials, labour charges, scaffolding, curing complete as per specifications. Specification No. at all levels, leads and lifts ( actual lenght and height of jaali wall only be measured for payment)

12

1500

18000

... More
code28 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Ground Floor

186

204

38122.56

... More
code29 - Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.

9

7337

66034.08

... More
code30 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame.

1

6405

6405.28

... More
code31 - Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.

2134

152

325050.88

... More
code32 - Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.

76

1000

76012.16

... More
code33 - Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

9

5015

45138.24

... More
code34 - Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.

0.18

110672

19921.104

... More
code35 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.. -do- 35 mm thick both side commercial

6.5

3720

24184.16

... More
code36 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 150mm

10

903

9038.4

... More
code37 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 35 mm thickness

3.15

4525

14256.648

... More
code38 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.

3

1137

3413.76

... More
code39 - Providing and fixing SS 304 Aldrop-250mm x 16mm (variation in size acceptable upto + / - 10%) suitable for door shutters including SS screws cost of materials, labour etc., complete as per specifications of vendor details. Make: Dorset / Godrej / Niell / Archis / Kadson / AKS / equivalent Model as per Specification.

3

1910

5730

... More
code40 - Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Ground Floor

3

1178

3534.72

... More
code41 - Providing and fixing Stainless Steel(304 grade) Cylindrical lock with key to door shutters including cost of materials, labour etc., complete as per specifications of vendor and as per architects details. Make - Dorset / Equivalent Approved Model

3

960

2880

... More
code42 - Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete

10

265

2654.4

... More
code43 - Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete Ground Floor

3

264

792.96

... More
code44 - Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 25x85x5.5 mm (heavy type) Ground Floor

15

308

4620

... More
code45 - Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete

10

145

1456

... More
code46 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Aldrop 16mm dia, 200mm No

4

336

1344

... More
code47 - Providing and fixing MS Holdfast of size 260mm x 25mm x 5mm thk for fixing door frame to walls including cost of materials, cutting masonry pockets for receiving MS Holdfast, one coat of shop primer , concrete filling of pockets, disposal of debris, keeping the area clean, curing, labour etc., complete as per specifications of vendor and as per architects details.

18

40

720

... More
code48 - Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge.

6

7465

44795.52

... More
code49 - Extra for making chequers of approved pattern on 1:2:4 cement concrete floors, steps, landing, pavements etc.

13.5

61

831.6

... More
code50 - Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Tile 600x600 mm

46

1316

60536

... More
code51 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. 6mm Thick Ground Floor

8

1205

9640.96

... More
code52 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. Ground Floor

32

1622

51932.16

... More
code53 - Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.

2

4888

9776.64

... More
code54 - Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

4

661

2647.68

... More
code55 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal wall plastering Ground Floor

254

312

79369.92

... More
code56 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Rough plastering Ground Floor

32

330

10572.8

... More
code57 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Plastering Ground Floor

574

415

238508.48

... More
code58 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

86

349

30051.84

... More
code59 - Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. Plaster mesh 100mm wide Ground Floor

314

38

11957.12

... More
code60 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ( Ground Floor

340

112

38080

... More
code61 - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. Ground Floor

340

182

62070.4

... More
code62 - Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. & Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

574

159

91288.96

... More
code63 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground Floor

251

128

32328.8

... More
code64 - Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Terrace Floor

3904

153

600591.36

... More
code65 - Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Terrace Floor

195

642

125291.4

... More
code66 - Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) Terrace Floor

40

510

20406.8

... More
code67 - Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth) Terrace Floor

79

1214

95977.1

... More
code68 - Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m

37

271

10028.48

... More
code69 - Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m

38

290

11023.04

... More
code70 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

26

297

7745.92

... More
code71 - Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work

49

95

4664.8

... More
code72 - Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates

3

6343

19031.04

... More
code73 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (Rate is inclusive of Shuttering) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

16

7096

113541.12

... More
code74 - Addtionalities for Form Work for combined Footing @8%

5.148

212

1095.90624

... More
code75 - Addtionalities for Form Work for retaining wall @10%

7.9

709

5606.077

... More
code76 - Addtionalities for Form Work for Slab@50%

2.574

3548

9132.96384

... More
code77 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Ground Floor

1.553

100191

155597.92752

... More
code78 - Food Graded Water Proofing Membrane Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification.

52

567

29527.68

... More
code79 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates Ground Floor

1.5

6992

10488.24

... More
code80 - Supplying and fixing of heavy duty SFRC manhole cover with frame 560MM size for underground tank.

1

5500

5500

... More
code81 - Providing and fixing of PVC Rungs footrest in under ground tanks / manhole using M20 concrete bed blocks for masonry walls or during construction for RCC surfaces, including cost of materials, labour, curing etc., complete as per specifications.

6

300

1800

... More
code82 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap a) Ground Floor

2

2626

5252.8

... More
code83 - Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover,and cistern fittings, nuts, bolts and gasket etc complete. a) Ground Floor

2

12570

25141.76

... More
code84 - Providing and fixing CP. Health faucet with flexible hose,CP Bibcock with 2 in 1 connectvity, wall flange, supporting hook with screws, fixing materials and sealant to all sides of wall flange complete. Make :

2

3000

6000

... More
code85 - Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931

24

711

17068.8

... More
code86 - Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.

8

812

6496

... More
code87 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

10

1366

13664

... More
code88 - Supplying , shifting to the place of installation and fixing testing and commissioning of stainless steel soap dish 150 x 150mm including cutting and setting in walls with cement joints and making good the wall. Make : JAQUAR Model No- ACN -1131N

12

834

10008

... More
code89 - Providing and fixing 2 in 1 Wall Mixer with complete fitting comprising of with provision for with long bend spout for bucket with wall flange complete.

4

5580

22320

... More
code90 - Providing and fixing shower head Arm with rose long bend free flow with fitting wall flange complete, including teflon with fixing.

4

2616

10464

... More
code91 - 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.

4

555

2222.08

... More
code92 - Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm Dia

12

103

1236.36

... More
code93 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 75mm dia., 6 kg/sqcm & class 3

60

246

14784

... More
code94 - Supply and delivery at site special moulded variety 75 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

20

75

1500.6

... More
code95 - Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

20

215

4300.8

... More
code96 - Supply and delivery at site special moulded variety 75 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

12

131

1572.48

... More
code97 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3

70

460

32222.4

... More
code98 - Supply and delivery at site special moulded variety 110 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

20

191

3830.4

... More
code99 - Supply and delivery at site special moulded variety 110 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

20

338

6764.8

... More
code100 - Supply and delivery at site special moulded variety 110 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

20

281

5622.4

... More
code101 - Providing & fixing, testing and commissioning u PVC multi inlet floor trap 75mm dia conforming to IS 13592 with required P C C support placed to required level as per site condition complete..

32

552

17664

... More
code102 - Supplying and fixing PVC P' trap 110mm dia, of self cleansing design with or without vent arm complete including cutting and making good the walls and floors.

8

732

5856

... More
code103 - Providing & Fixing in position heavy duty C P grating 125mm dia, with frame of below mentioned sizes including jointing and fixing material complete.

30

282

8460

... More
code104 - Providing and grouting sleeves made in beam/ slab to draw waste and soil lines at all floor level of the below mentioned sizes , including condcting water ponding test to ensure zero leakage with all leads and lifts complete Size : 150 mm dia

16

720

11520

... More
code105 - Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete,As per direction of engineer in charge Concealed work including cutting chases and good the walls etc. 20 mm dia pipe nominal OD pipes

100

424

42448

... More
code106 - Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete,As per direction of engineer in charge Concealed work including cutting chases and good the walls etc. 25 mm dia pipe nominal OD pipes

20

534

10684.8

... More
code107 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :20 mm nominal bore.

4

351

1406.72

... More
code108 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

4

614

2459.52

... More
code109 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm dia pipe nominal OD pipes

72

243

17498.88

... More
code110 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia pipe nominal OD pipes

40

331

13260.8

... More
code111 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm dia pipe nominal OD pipes

42

416

17498.88

... More
code112 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 40 mm dia pipe nominal OD pipes

40

534

21369.6

... More
code113 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia pipe nominal OD pipes

20

807

16150.4

... More
code114 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :20 mm nominal bore.

16

351

5626.88

... More
code115 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25 mm nominal bore.

16

614

9838.08

... More
code116 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

16

669

10716.16

... More
code117 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

8

786

6289.92

... More
code118 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

2

957

1915.2

... More
code119 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

1000

10

10080

... More
code120 - Supplying & fixing suction Y'/ pot stainer with MS flange of suitable length fabricated from 16 gauge brass sheet with 3mm slots. 50 mm dia

2

4344

8688

... More
code121 - Supplying , fixing, testing and commissioning of PVC welded rain water head / khurras dome type grating with puddle flange to fix head in RCC slab specially fabricated from minimum 4mm thick PVC sheet, including removable heavy duty PVC grating of 50 x 3 mm thick PVC flats (Round or Square) as per approved design The quoted rate shall include for necessary grouting the khurras base with approved sealant complete all as shown in the drawing and as specified. 150 x 150mm PVC Grating

4

830

3320

... More
code122 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:

55

246

13552

... More
code123 - Supply and delivery at site special moulded variety 75 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

10

75

750.3

... More
code124 - Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

10

215

2150.4

... More
code125 - Supply and delivery at site special moulded variety 75 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

10

131

1310.4

... More
code126 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 a) Ground Floor

132

460

60762.24

... More
code127 - Supply and delivery at site special moulded variety 110 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

12

191

2298.24

... More
code128 - Supply and delivery at site special moulded variety 110 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

10

338

3382.4

... More
code129 - Supply and delivery at site special moulded variety 110 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

10

281

2811.2

... More
code130 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 160mm dia., 6 kg/sqcm & class 3

14

692

9690.24

... More
code131 - Supply and delivery at site special moulded variety 160 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

8

375

3001.6

... More
code132 - Supply and delivery at site special moulded variety 160 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

8

527

4220.16

... More
code133 - Supply and delivery at site special moulded variety 160 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

10

521

5219.2

... More
code134 - Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete

5

387

1937.6

... More
code135 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover

9

6108

54976.32

... More
code136 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m

63.6

542

34476.288

... More
code137 - DOMESTIC WATER TRANSFAR PUMP Supplying, installing, testing and commissioning of submersible / Mono blockelectrical driven pump 1set . (1 working & standby) domestic water pumps for pumping domestic water from U.G. sump to over head water tank, with all necessary arrangements to operate on 3HP 50 HZ, 440V AC supply fitted on a common base frame accessories to lift the pump during maintenance , necessary power connections, the supplier shall include the control panel and wiring from TPN switch to control panel and wiring upto pumps, the control panel comprising of O/L relays, single phase preventor,separate overload trip and relayset, ON/OFF/TRIP indicating lamps,start/stop push buttons, With liquid level controlers, etc., complete as complete. Duty of the Pump 4 cum per hour at 20 TO 25 m head Make : Kirloskar/ suguna/texmo/CRI two set industrial type electronic automatic liquid level controllers, with stainless steel probes / sensors.

2

24000

48000

... More
code138 - Providing and fixing gun metal non- return valve of approved quality (screwed end) 32 mm nominal bore Vertical

2

1036

2072

... More
code139 - Providing and fixing gun metal non- return valve of approved quality (screwed end) 40 mm nominal bore Vertical

2

1372

2744

... More
code140 - Construction of brick masonry catch basin chamber chambers of internal clear dimension as mentioned below by using first class table moulded modular bricks 230 mm thick wall in cement mortor joints in 1:4, over CC 1:4:8 bed 150 mm thick including Supplying precast RCC perforated top slab in 1:2:4 Mix (1 cement: 2 coarse coarse sand: 8 graded stone aggregate), with angle iron frame, inside plastering15mm thick with CM 1:3 (1 cement::3 fine sand) finished very smooth with floating coat of neat cement & making benching and channelling in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 gradedstone aggregate) neatly finished complete as per standard design and as per drawing and specifications.Inside size of 600 x 600mm & depth not exceeding 600 x 600mm including Supplying 450 x 450mm RCC cover with MS L angle frame.

4

6920

27681.6

... More
code141 - Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. 32 mm dia

2

696

1392

... More
code142 - Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. 40 mm dia

2

828

1656

... More
code143 - Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. 50 mm dia

2

1044

2088

... More
code144 - Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. 65 mm dia

2

1398

2796

... More
code145 - LT ELECTRICAL WORKS PVC CONDUITS & ITS ACCESSORIES Open conduit System Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. a) 19/20 mm dia 2mm thick

250

69

17250

... More
code146 - Open conduit System Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. b) 25mm dia 2mm thick

450

81

36450

... More
code147 - Open conduit System Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. c) 32mm dia 2.5mm thick

50

106

5300

... More
code148 - Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc. By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary a) 19/20 mm dia 2mm thick

20

68

1360

... More
code149 - Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc. By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary b) 25mm dia 2mm thick

40

79

3160

... More
code150 - Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc. By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary c) 32mm dia 2.5mm thick

10

99

990

... More
code151 - Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm..using NF screws and on either end of the pipe terminated completely. a) 25 mm

100

22

2200

... More
code152 - Supplying and fixing Metal fan box with round hook.

2

117

234

... More
code153 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. a) Short point up to 3Mtr from tapping point to out let via switch box

15

269

4035

... More
code154 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. b) Medium point above 3Mtr up to 6Mtrs from tapping point to out let via switch box

20

379

7580

... More
code155 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box

30

555

16650

... More
code156 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. d) Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switch box

5

677

3385

... More
code157 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. e) Three outlet in a row, above 6Mtr up to 10Mtr from tapping point to out let via switches box

2

989

1978

... More
code158 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. a) 1.5 sqmm

200

26

5200

... More
code159 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. b) 2.5 sqmm

500

42

21000

... More
code160 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. c) 4 sqmm

300

63

18900

... More
code161 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. d) 6 sqmm

50

92

4600

... More
code162 - Supplying and Drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130-1984 and (virgin) PVC insulation and sheathed suitable for working voltage upto 1100volts as per IS-694:1990. a) 3Cx2.5Sqmm

50

113

5650

... More
code163 - Supplying and Drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130-1984 and (virgin) PVC insulation and sheathed suitable for working voltage upto 1100volts as per IS-694:1990. b) 3Cx4.0Sqmm

75

172

12900

... More
code164 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall a) 1-2 Way

5

138

690

... More
code165 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall b) 3 Way

15

159

2385

... More
code166 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall c) 4 Way

5

177

885

... More
code167 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall d) 6 Way

10

220

2200

... More
code168 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall e) 8 Way

5

261

1305

... More
code169 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall f) 10-12 Way

2

319

638

... More
code170 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall g) 16 Way

2

363

726

... More
code171 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall h) 18 Way

1

405

405

... More
code172 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. a) 1 to 2 Module

5

137

685

... More
code173 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. b) 3 Module

15

161

2415

... More
code174 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. c) 4 Module

5

175

875

... More
code175 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. d) 6 Module

10

234

2340

... More
code176 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. e) 8 Module

5

284

1420

... More
code177 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. f) 10-12 Module

2

344

688

... More
code178 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. g) 16 Module

2

397

794

... More
code179 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. h) 18 Module

1

457

457

... More
code180 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 a) 6 Amps one way

80

102

8160

... More
code181 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 b) 6 Amps Two way

2

166

332

... More
code182 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 c) 6Amps 3way socket.

10

171

1710

... More
code183 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 d) Stepped fan regulator

2

357

714

... More
code184 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 e) 32A,DP,Switch

5

326

1630

... More
code185 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 f) 16Amps one way switch

5

180

900

... More
code186 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 g) 6/16Amps universal socket

10

236

2360

... More
code187 - CONTROL SWITCH GEARS & ACCESSORIES Supplying push button operated, direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 400/440 volts 3 phase motor/single phase motor upto 5 HP.

1

1927

1927

... More
code188 - Supplying and fixing regular MCB distributionpanel confirming to IS 8828 , on wall/wood board/ flush mounting using required clamps, bolts, nuts etc.. With provision for fixing of suitable type capacity ELMCB / MCb's as an incomer for 3 phase double door with necessary bus bar completely wired to use on 440volts 3 phase 4 wired powder coated painting etc.. complete with provision for fixing of single/three phase suitable capacity ELMCB/MCb's as outgoings confirming to IS8828 . 8 way

1

12605

12605

... More
code189 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. a) 5-32Amps SP

12

415

4980

... More
code190 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. b) 5-32Amps DP

2

739

1478

... More
code191 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. c) 5-32Amps TPN

16

1717

27472

... More
code192 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. d) 40Amps TPN

1

3044

3044

... More
code193 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. e) 63Amps TPN

1

3088

3088

... More
code194 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure a) Double Door 4 Way SP & N

1

1524

1524

... More
code195 - Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/ panel board. a) 63Amps 4 pole

1

5545

5545

... More
code196 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron ….and M.S. flat with bolts, washers etc… and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6

30

305

9150

... More
code197 - Supplying and fixing of metal Socket set of 2 pole and earth plugs and socket for incorporating SP and TP MCB (without MCB). The entire Plug and Socket shall be mounted in athermoplastic / powder coated metal box & wired completely. SP & N 20Amps

1

971

971

... More
code198 - Supplying and fixing of metal Socket set of 2 pole and earth plugs and socket for incorporating SP and TP MCB (without MCB). The entire Plug and Socket shall be mounted in athermoplastic / powder coated metal box & wired completely. TP & N 30Amps

1

1700

1700

... More
code199 - EARTHING AND L.T. U.G. CABLES Supplying fixing and wiring earth electrode for grounding of DG Sets etc. using 40mm dia 2.9mm thick 2.5mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.

2

4256

8512

... More
code200 - Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. a) GI strip 25x3mm

50

82

4100

... More
code201 - Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. b) 600x600x3mm GI Plate

2

875

1750

... More
code202 - Supplying, Fixing & proper termination of vertical Air-termination using Gunmetal ball with finials of 5 spikes mounted on 2 mtrs long copper rod, mounted at the highest point of the building, with base plates, connection with horizontal conductor, necessary civil works, etc.

1

7500

7500

... More
code203 - Supply & fixing Test Link as per specification & drgs. and grouted to wall at 1200 mm. above ground level complete with all fixing accessories, clamps, screws etc, enclosed in M.S box.

1

3500

3500

... More
code204 - Supplying & Fixing Chemical earthing for grounding, conduits, IC cut outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10 ft copper bonded rod with backfill compound

2

8494

16988

... More
code205 - Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.. 8 SWG GI wire.

0.1

75040

7504

... More
code206 - Supplying of 1.1KV LT UG Aluminium cable XLPE insulated, PVC extruded inner sheathed, armourd UG LT cable as per the IS - 1554 (part-1) or IS-7098 part-1, Armoring strip thickness in average + 5% and resistivity 14 Ohms/Kms (Max) as per IS -3975. a) 4 core 16 sq.mm

0.15

141842

21276.3

... More
code207 - Labour charges for laying of 1.1 KV class UG cable in the existing trench GI pipe / stoneware pipe / on wall / on pole as required. On wall / Structure. a) 2.5 sqmm to 25 sqmm

0.15

20886

3132.9

... More
code208 - Supplying and fixing of heavy duty cable glands suitable for UG cable of1.1 KV class (metal only) a) 25mm

2

79

158

... More
code209 - Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. a) 150x50mm

10

463

4630

... More
code210 - Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. b) 300x50mm

5

587

2935

... More
code211 - Aluminium End Terminal (Lug) a) 6 / 10 sq.mm

20

2

40

... More
code212 - Aluminium End Terminal (Lug) b) 16 sq.mm

10

2

20

... More
code213 - FANS Supplying exhaust fan of 1440RPM heavy duty with bracket blades complete for lighting duty suitable to operate on 230V 50Hz, AC supply.. 12" sweep (300mm)

5

2969

14845

... More
code214 - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W 5 STAR 48 Sweep 5 Star (1200mm)

2

2677

5354

... More
code215 - Fixing all types and all capacities fluorescent /false ceiling/spot light/CFL/LED fittings indoor on the wall / ceiling / rafters / girders using 23 / 0.00076 " twin twisted PVC insulated wires, required nos of round blocks and clamps. On wall / ceiling / Rafters / Girders

75

122

9150

... More
code216 - Using 2 Mtr long 19mm 18SWG enamelled braised conduit of two nos. rod pendent with ball socket with check nuts all nickel painted.

20

570

11400

... More
code217 - Extra length of GI pipe of class b 19mm dia for down rod.

20

197

3940

... More
code218 - Fixing a ceiling/wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing a 5 amps ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.

2

315

630

... More
code219 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.

5

492

2460

... More
code220 - LED LUMINAIRS / LIGHT FIXTURES & ACCESSORIES Supplying and fixing of LED Bulk head of 10Wwith IP65 protection and IK08 impact resistance suitable for surfaceandwallmounting applications.

5

842

4210

... More
code221 - Supplying of 2' feet - LED PVC Square Batten …W with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with CRI 8. Power Input : 220-240V @ 50 Hz & power factor . 0.9 along with CE approved drivers. 2 years warranty against any manufacturing defect working under standard electrical condition. a) Led light fitting 2' - 9 / 10 watts

10

551

5510

... More
code222 - Supplying of 2' feet - LED PVC Square Batten …W with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with CRI 8. Power Input : 220-240V @ 50 Hz & power factor . 0.9 along with CE approved drivers. 2 years warranty against any manufacturing defect working under standard electrical condition. b) Led light fitting 4' - 20 / 22 watts

35

690

24150

... More
code223 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. 70-80W FLOOD LED LIGHT

4

6768

27072

... More
code224 - Supplying, erecting, testing & commissioning of ONLINE UPS System suitable for operation on 230V, 50Hz, A/C supply with isolation transformer all accessories complete and Excluding batteries and wiring complete 1 KVA OFFLINE UPS

1

23648

23648

... More
code225 - Supplying, installation, testing & commissioning of 12volts DC AH Batteries in poly propylene container for UPS Low maintenance Tubular/smf batteries. 12V, 75-80 AH Capacity. Acid battery.

2

10172

20344

... More
code226 - CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 1/3" progressive scan CMOS, 4.0 megapixel, IP based Colour camera, with 3-12mm verifocal lens, Up to 30 m IR range, Color: 0.01Lux, 1000TVL, Digital WDR (Wide Dynamic Range), 3D DNR (Digital Noise Reduction), PoE (Power over Ethernet/1 RJ45 10M/100M self-adaptive Ethernet port), IP67, Motion detection, Alarms (Video tampering, network disconnected, IP address conflicted), Protocols (TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, RTCP, NTP, UPnP, SMTP, IGMP, 802.1X, QoS, IPv6, Bonjour), Standard (ONVIF(PROFILE S,PROFILE G),PSIA,CGI,ISAPI), General Function (Anti-flicker, heartbeat, mirror, password protection, privacy mask, watermark), with base box, other necessary accessories. The cost shall includes end terminations.

6

11250

67500

... More
code227 - Supply, Installation, Testing & Commissioning of 8port 10/100/1000 Smart POE Switch with 4 SFP (192W)for camera connection including all necessary accessories.

1

7500

7500

... More
code228 - Supply, Installation, Testing & Commissioning of NVR (Networkable Video Recorder) - 8Channel NVR, Up to 8ch IP cameras input, Up to 5 Megapixels resolution recording HDMI and VGA output at up to 19201080P resolution, HDD quota and group management 4 SATA, 3 USB, interface, 1 RJ45 10 /100 /1000 Mbps self-adaptive Ethernet interface

1

20000

20000

... More
code229 - Supply, Installation, Testing & Commissioning of HDMI, Display Monitor 32" high resolution, Monitor with all mounting bracket accessories.

1

32000

32000

... More
code230 - Supply, laying and termination of CAT6 UTP, cable for IP BASED Camera power and video connection in existing Conduit / pipe.

200

34

6800

... More
code231 - Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Manual Means a) In area of light jungle

1.31

1256

1646.1853

... More
code232 - Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.. In all kinds of soils upto 300 mm depth

39.5

106

4202.8

... More
code233 - Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m

99

271

26832.96

... More
code234 - Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m

30

290

8702.4

... More
code235 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

25.8

297

7686.336

... More
code236 - Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work

143

95

13613.6

... More
code237 - Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work.

114

530

60520.32

... More
code238 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.

82.8

132

10942.848

... More
code239 - Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates

12

6343

76124.16

... More
code240 - Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates

6.5

6963

45259.76

... More
code241 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (Rate is inclusive of Shuttering) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

25

7096

177408

... More
code242 - Shuttering Work for Isolated Footing @8%

13.608

567

7725.2616

... More
code243 - Shuttering Work for Pedestals @70%

4.032

4967

20028.63744

... More
code244 - Shuttering Work for Columns Upto Plinth Beam @70%

1.45

4967

7202.759

... More
code245 - Shuttering Work for Plinth Beam @50%

5.589

3548

19830.66624

... More
code246 - Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates

14

7257

101606.4

... More
code247 - Shuttering Work for Wall@ 10%

14

725

10160.64

... More
code248 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Rate is inclusive of Shuttering) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

30

7664

229924.8

... More
code249 - Shuttering Work for Columns @ 70%- Ground Floor

4.06

5364

21781.5346

... More
code250 - Shuttering Work for Roof Beam, Lintel Beam @ 60%-Ground Floor

6.88

4598

31637.6112

... More
code251 - Shuttering Work for Sloped Roof Slab @ 70%- Ground Floor

18.144

5364

97340.92704

... More
code252 - Shuttering Work for Chajja @ 45% Ground Floor

0.81

3448

2793.5847

... More
code253 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a) Ground Floor

6.276

100191

628803.98784

... More
code254 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. a) Ground Floor

125

1467

183400

... More
code255 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. a) Ground floor

3

1236

3709.44

... More
code256 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. a) Ground Floor

1061

204

217462.56

... More
code257 - Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. T

22

7337

161416.64

... More
code258 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass

29

6405

185753.12

... More
code259 - Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

38

632

24046.4

... More
code260 - Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.

1001

152

152472.32

... More
code261 - Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.

0.4

110672

44269.12

... More
code262 - Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications.. ( excluding cost of fixtures )

4.5

7724

34760.88

... More
code263 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.. -do- 35 mm thick both side commercial

8.5

3720

31625.44

... More
code264 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.

5

1137

5689.6

... More
code265 - Providing and fixing SS 304 Aldrop-250mm x 16mm (variation in size acceptable upto + / - 10%) suitable for door shutters including SS screws cost of materials, labour etc., complete as per specifications of vendor details. Make: Dorset / Godrej / Niell / Archis / Kadson / AKS / equivalent Model as per Specification.

5

1910

9550

... More
code266 - Providing and fixing Stainless Steel(304 grade) Cylindrical lock with key to door shutters including cost of materials, labour etc., complete as per specifications of vendor and as per architects details. Make - Dorset / Equivalent Approved Model

5

960

4800

... More
code267 - Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete

12

265

3185.28

... More
code268 - Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete a) Ground Floor

10

264

2643.2

... More
code269 - Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 25x85x5.5 mm (heavy type) a) Ground Floor

18

308

5544

... More
code270 - Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete

20

145

2912

... More
code271 - Providing and fixing MS Holdfast of size 260mm x 25mm x 5mm thk for fixing door frame to walls including cost of materials, cutting masonry pockets for receiving MS Holdfast, one coat of shop primer , concrete filling of pockets, disposal of debris, keeping the area clean, curing, labour etc., complete as per specifications of vendor and as per architects details.

30

40

1200

... More
code272 - Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. C) Terrace Floor

121

924

111826.99

... More
code273 - Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates

1

7032

7032.67

... More
code274 - Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent..

4

2761

11047.68

... More
code275 - Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.

9

367

3306.24

... More
code276 - Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Tile 600x600 mm

77

1316

101332

... More
code277 - Providing and fixing of prepigmented extruded orange cement roof tiles of size 420mmx330mm with necessary specials such as Ridges , barges and nails etc including cost of providing PVC (6.00 kg/cm2) gutters of min 6" radius and down water pipes of 4" dia as per roof design on Existing Concrete Sloping Roof Slab. Including cost of mortar band, all materials labour as per specifications. b)Terrace Floor

121

790

95674.7

... More
code278 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal wall plastering a) Ground Floor

257

312

80307.36

... More
code279 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Plastering a) Ground Floor

127

415

52771.04

... More
code280 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

121

349

42282.24

... More
code281 - Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. Plaster mesh 100mm wide a) Ground Floor

302

38

11500.16

... More
code282 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (a) Ground Floor

378

112

42336

... More
code283 - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. a) Ground Floor

378

182

69007.68

... More
code284 - Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. & Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

127

159

20198.08

... More
code285 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. a) Ground Floor

51

128

6568.8

... More
code286 - Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

13

154

2009.28

... More
code287 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 75mm dia., 6 kg/sqcm & class 3

8

246

1971.2

... More
code288 - Supply and delivery at site special moulded variety 75 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

4

75

300.12

... More
code289 - Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

4

215

860.16

... More
code290 - Supply and delivery at site special moulded variety 75 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

4

131

524.16

... More
code291 - Providing & fixing, testing and commissioning u PVC multi inlet floor trap 75mm dia conforming to IS 13592 with required P C C support placed to required level as per site condition complete..

4

552

2208

... More
code292 - Providing & Fixing in position heavy duty C P grating 125mm dia, with frame of below mentioned sizes including jointing and fixing material complete.

4

282

1128

... More
code293 - Providing and grouting sleeves made in beam/ slab to draw waste and soil lines at all floor level of the below mentioned sizes , including condcting water ponding test to ensure zero leakage with all leads and lifts complete Size : 150 mm dia

4

720

2880

... More
code294 - Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete,As per direction of engineer in charge Concealed work including cutting chases and good the walls etc. 20 mm dia pipe nominal OD pipes

24

534

12821.76

... More
code295 - Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931

4

711

2844.8

... More
code296 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :20 mm nominal bore.

1

351

351.68

... More
code297 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

1

614

614.88

... More
code298 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm dia pipe nominal OD pipes

8

416

3333.12

... More
code299 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

1000

10

10080

... More
code300 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

2

669

1339.52

... More
code301 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:

20

246

4928

... More
code302 - Supply and delivery at site special moulded variety 75 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

4

75

300.12

... More
code303 - Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

4

215

860.16

... More
code304 - Supply and delivery at site special moulded variety 75 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

4

131

524.16

... More
code305 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 160mm dia., 6 kg/sqcm & class 3

30

692

20764.8

... More
code306 - Supply and delivery at site special moulded variety 160 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

5

375

1876

... More
code307 - Supply and delivery at site special moulded variety 160 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

5

527

2637.6

... More
code308 - Supply and delivery at site special moulded variety 160 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

5

521

2609.6

... More
code309 - Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete

4

387

1550.08

... More
code310 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover

4

6108

24433.92

... More
code311 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m

18.96

542

10277.8368

... More
code312 - LT ELECTRICAL WORKS PVC CONDUITS & ITS ACCESSORIES Open conduit System Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. a) 19/20 mm dia 2mm thick

30

69

2070

... More
code313 - Open conduit System Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. b) 25mm dia 2mm thick

50

81

4050

... More
code314 - Concealed conduit System Supplying heavy gauge PVC conduit pipe ……mm dia ......mm thick confirming to IS 2509 with suitable size bends, metals/PVC junction boxes, adhesives paste etc., and running before concreting the slab . The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. a) 19/20 mm dia 2mm thick

75

66

4950

... More
code315 - Concealed conduit System Supplying heavy gauge PVC conduit pipe ……mm dia ......mm thick confirming to IS 2509 with suitable size bends, metals/PVC junction boxes, adhesives paste etc., and running before concreting the slab . The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. b) 25mm dia 2mm thick

90

78

7020

... More
code316 - Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc. By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary a) 19/20 mm dia 2mm thick

10

68

680

... More
code317 - Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc. By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary b) 25mm dia 2mm thick

15

79

1185

... More
code318 - Supplying and fixing PVC/metal conduit deep junction box. a) 19/20mm deep junction box

5

49

245

... More
code319 - Supplying and fixing PVC/metal conduit deep junction box. b) 25mm deep junction box

15

56

840

... More
code320 - Supplying and fixing Metal fan box with round hook.

5

117

585

... More
code321 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. a) Short point up to 3Mtr from tapping point to out let via switch box

2

269

538

... More
code322 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. b) Medium point above 3Mtr up to 6Mtrs from tapping point to out let via switch box

4

379

1516

... More
code323 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box

5

555

2775

... More
code324 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. d) Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switch box

3

677

2031

... More
code325 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. a) 1.5 sqmm

50

26

1300

... More
code326 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. b) 2.5 sqmm

100

42

4200

... More
code327 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. c) 4 sqmm

150

63

9450

... More
code328 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. d) 6 sqmm

50

92

4600

... More
code329 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall a) 1-2 Way

3

138

414

... More
code330 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall a)3 Way

3

159

477

... More
code331 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall b) 4 Way

2

177

354

... More
code332 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall c) 6 Way

5

220

1100

... More
code333 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall d) 8 Way

2

261

522

... More
code334 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall e) 10-12 Way

4

319

1276

... More
code335 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. a) 1 - 2 Module

3

137

411

... More
code336 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. b) 3 Module

3

161

483

... More
code337 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. b) 4 Module

2

175

350

... More
code338 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. c) 6 Module

5

234

1170

... More
code339 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. d) 8 Module

2

284

568

... More
code340 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. e) 10-12 Module

4

344

1376

... More
code341 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 a) 6 Amps one way

25

102

2550

... More
code342 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 b) 6 Amps Two way

2

166

332

... More
code343 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 c) 6Amps 3way socket.

5

171

855

... More
code344 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 d) Stepped fan regulator

5

357

1785

... More
code345 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 e) 16Amps one way switch

10

180

1800

... More
code346 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 f) 6/16Amps universal socket

10

236

2360

... More
code347 - CONTROL SWITCH GEARS & ACCESSORIES Supplying push button operated, direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 400/440 volts 3 phase motor/single phase motor upto 5 HP.

1

1927

1927

... More
code348 - Supplying and fixing regular MCB distributionpanel confirming to IS 8828 , on wall/wood board/ flush mounting using required clamps, bolts, nuts etc.. With provision for fixing of suitable type capacity ELMCB / MCb's as an incomer for 3 phase double door with necessary bus bar completely wired to use on 440volts 3 phase 4 wired powder coated painting etc.. complete with provision for fixing of single/three phase suitable capacity ELMCB/MCb's as outgoings confirming to IS8828 . 4 way

1

10329

10329

... More
code349 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. a) 5-32Amps SP

12

415

4980

... More
code350 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. b) 5-32Amps DP

2

739

1478

... More
code351 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure a) Double Door 4 Way SP & N

1

1524

1524

... More
code352 - Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/ panel board. a) 32-40Amps 4 pole

1

5147

5147

... More
code353 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron ….and M.S. flat with bolts, washers etc… and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6

5

305

1525

... More
code354 - EARTHING AND L.T. U.G. CABLES Supplying fixing and wiring earth electrode for grounding of DG Sets etc. using 40mm dia 2.9mm thick 2.5mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.

1

4256

4256

... More
code355 - Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. a) GI strip 25x3mm

20

82

1640

... More
code356 - Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. b) 600x600x3mm GI Plate

2

875

1750

... More
code357 - Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.. 8 SWG GI wire.

0.1

75040

7504

... More
code358 - Supplying of 1.1KV LT UG Aluminium cable XLPE insulated, PVC extruded inner sheathed, armourd UG LT cable as per the IS - 1554 (part-1) or IS-7098 part-1, Armoring strip thickness in average + 5% and resistivity 14 Ohms/Kms (Max) as per IS -3975. a) 4 core 16 sq.mm

0.05

141842

7092.1

... More
code359 - Labour charges for laying of 1.1 KV class UG cable in the existing trench GI pipe / stoneware pipe / on wall / on pole as required. On wall / Structure. a) 2.5 sqmm to 25 sqmm

0.05

20886

1044.3

... More
code360 - Supplying and fixing of heavy duty cable glands suitable for UG cable of1.1 KV class (metal only) a) 25mm

2

79

158

... More
code361 - Aluminium End Terminal (Lug) a) 6 / 10 sq.mm

10

2

20

... More
code362 - FANS Supplying exhaust fan of 1440RPM heavy duty with bracket blades complete for lighting duty suitable to operate on 230V 50Hz, AC supply.. 12" sweep (300mm)

5

2969

14845

... More
code363 - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.. 5 STAR 48 Sweep 5 Star (1200mm)

5

2677

13385

... More
code364 - Fixing all types and all capacities fluorescent /false ceiling/spot light/CFL/LED fittings indoor on the wall / ceiling / rafters / girders using 23 / 0.00076 " twin twisted PVC insulated wires, required nos of round blocks and clamps. On wall / ceiling / Rafters / Girders

20

122

2440

... More
code365 - Using 2 Mtr long 19mm 18SWG enamelled braised conduit of two nos. rod pendent with ball socket with check nuts all nickel painted.

5

570

2850

... More
code366 - Extra length of GI pipe of class b 19mm dia for down rod.

5

197

985

... More
code367 - Fixing a ceiling/wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing a 5 amps ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.

5

315

1575

... More
code368 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.

5

492

2460

... More
code369 - LED LUMINAIRS / LIGHT FIXTURES & ACCESSORIES Supplying and fixing of LED Bulk head of 10Wwith IP65 protection and IK08 impact resistance suitable for surfaceandwallmounting applications.

6

842

5052

... More
code370 - Supplying of 2' feet - LED PVC Square Batten …W with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with CRI 8. Power Input : 220-240V @ 50 Hz & power factor . 0.9 along with CE approved drivers. 2 years warranty against any manufacturing defect working under standard electrical condition. a) Led light fitting 4' - 20 / 22 watts

15

690

10350

... More
code371 - Supplying of Surface / recess mounting non integrated type LED down light …W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power / COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit THD Less then 20%, Life as per LM 79, The operating input voltage should be between 130 to 275 volts, BIS Approved and tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 10-12W

2

885

1770

... More
code372 - CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 1/3" progressive scan CMOS, 4.0 megapixel, IP based Colour camera, with 3-12mm verifocal lens, Up to 30 m IR range, Color: 0.01Lux, 1000TVL, Digital WDR (Wide Dynamic Range), 3D DNR (Digital Noise Reduction), PoE (Power over Ethernet/1 RJ45 10M/100M self-adaptive Ethernet port), IP67, Motion detection, Alarms (Video tampering, network disconnected, IP address conflicted), Protocols (TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, RTCP, NTP, UPnP, SMTP, IGMP, 802.1X, QoS, IPv6, Bonjour), Standard (ONVIF(PROFILE S,PROFILE G),PSIA,CGI,ISAPI), General Function (Anti-flicker, heartbeat, mirror, password protection, privacy mask, watermark), with base box, other necessary accessories. The cost shall includes end terminations.

4

11250

45000

... More
code373 - Supply, Installation, Testing & Commissioning of 8port 10/100/1000 Smart POE Switch with 4 SFP (192W)for camera connection including all necessary accessories.

1

7500

7500

... More
code374 - Supply, Installation, Testing & Commissioning of NVR (Networkable Video Recorder) - 4Channel NVR, Up to 4ch IP cameras input, Up to 5 Megapixels resolution recording HDMI and VGA output at up to 1920 1080P resolution

1

10500

10500

... More
code375 - Supply, Installation, Testing & Commissioning of HDMI, Display Monitor 32" high resolution, Monitor with all mounting bracket accessories.

1

32000

32000

... More
code376 - Supply, laying and termination of CAT6 UTP, cable for IP BASED Camera power and video connection in existing Conduit / pipe.

75

34

2550

... More
code377 - Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Manual Means a) In area of light jungle

5

1256

6283.15

... More
code378 - Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.. In all kinds of soils upto 300 mm depth

117

106

12448.8

... More
code379 - Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m

245

271

66404.8

... More
code380 - Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m

76

290

22046.08

... More
code381 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

65

297

19364.8

... More
code382 - Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work

374

95

35604.8

... More
code383 - Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work.

429

530

227747.52

... More
code384 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.

389

132

51410.24

... More
code385 - Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates

44

6343

279121.92

... More
code386 - Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates

6

6963

41778.24

... More
code387 - Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates b) First Floor

1

7032

7032.67

... More
code388 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (Rate is inclusive of Shuttering) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

65

7096

461260.8

... More
code389 - Shuttering Work for Isolated Footing @8%

36.078

567

20481.4806

... More
code390 - Shuttering Work for Pedestals @70%

8.4915

4967

42180.84693

... More
code391 - Shuttering Work for Columns Upto Plinth Beam @70%

6.03

4967

29953.5426

... More
code392 - Shuttering Work for Plinth Beam @50%

13.5234

3548

47983.186944

... More
code393 - Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates

10

7257

72576

... More
code394 - Shuttering Work for Wall@ 10%

10

725

7257.6

... More
code395 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Rate is inclusive of Shuttering) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

24.5

7664

187771.92

... More
code396 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Rate is inclusive of Shuttering) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates b) First Floor

73

7740

565078.4

... More
code397 - Shuttering Work for Columns @ 70%- Ground Floor

15.64

5364

83907.1924

... More
code398 - Shuttering Work for Columns @ 70%-First Floor

7.37

5418

39934.7872

... More
code399 - Shuttering Work for Roof Beam, Lintel Beam @ 60%-Ground Floor

5.93

4598

27269.0457

... More
code400 - Shuttering Work for Roof Beam, Lintel Beam @ 60%-First Floor

14.92

4644

69295.6416

... More
code401 - Shuttering Work for Roof Slab @ 50%- First Floor

50.2095

3870

194330.8488

... More
code402 - Shuttering Work for Chajja @ 45% Ground Floor

2.5

3448

8622.175

... More
code403 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a) Ground Floor

9.58

100191

959837.8272

... More
code404 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. b) First Floor

7.78

101193

787287.375

... More
code405 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. a) Ground Floor

380.5

1467

558269.6

... More
code406 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. b) First Floor

148

1481

219316.76

... More
code407 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. a) Ground floor

26.5

1236

32766.72

... More
code408 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. a) Ground Floor

1038.5

204

212850.96

... More
code409 - Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm

27

7337

198102.24

... More
code410 - Providing & fixing of 3-track 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm 75mm with GI reinforcement of 2mm and mesh sash of size 37mm 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall

3.5

7542

26397.28

... More
code411 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass

20.5

6405

131308.24

... More
code412 - Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

301

154

46522.56

... More
code413 - Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

16.5

2948

48657.84

... More
code414 - Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.

1

110672

110672.8

... More
code415 - Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications.. ( excluding cost of fixtures )

4

7724

30898.56

... More
code416 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.. -do- 35 mm thick both side commercial

125

3720

465080

... More
code417 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 150mm

21

903

18980.64

... More
code418 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 35 mm thickness

6.5

4525

29418.48

... More
code419 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.

9

1137

10241.28

... More
code420 - Providing and fixing SS 304 Aldrop-250mm x 16mm (variation in size acceptable upto + / - 10%) suitable for door shutters including SS screws cost of materials, labour etc., complete as per specifications of vendor details. Make: Dorset / Godrej / Niell / Archis / Kadson / AKS / equivalent Model as per Specification.

9

1910

17190

... More
code421 - Providing and fixing Stainless Steel(304 grade) Cylindrical lock with key to door shutters including cost of materials, labour etc., complete as per specifications of vendor and as per architects details. Make - Dorset / Equivalent Approved Model

4

960

3840

... More
code422 - Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete

38

265

10086.72

... More
code423 - Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete a) Ground Floor

16

264

4229.12

... More
code424 - Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 25x85x5.5 mm (heavy type) a) Ground Floor

60

308

18480

... More
code425 - Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete

40

145

5824

... More
code426 - Providing supply and fixing MS Holdfast of size 260mm x 25mm x 5mm thk for fixing door frame to walls including cost of materials, cutting masonry pockets for receiving MS Holdfast, one coat of shop primer , concrete filling of pockets, disposal of debris,keeping the area clean,curing, labour etc., complete as per specifications of vendor and as per architects details. at all levells

54

40

2160

... More
code427 - Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. C) First Floor

341

924

315148.79

... More
code428 - Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates

24

7032

168784.08

... More
code429 - Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent..

51

2761

140857.92

... More
code430 - Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.

23

367

8449.28

... More
code431 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.

35.5

995

35346.64

... More
code432 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.

110

1622

178516.8

... More
code433 - Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Tile 600x600 mm

32.5

1316

42770

... More
code434 - Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.

233

1730

403183.2

... More
code435 - Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.

16

4792

76679.68

... More
code436 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal wall plastering a) Ground Floor

561

312

175301.28

... More
code437 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal wall plastering b) First Floor

221.5

315

69905.4

... More
code438 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Rough plastering a) Ground Floor

110

330

36344

... More
code439 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Plastering a) Ground Floor

312.5

415

129850

... More
code440 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Plastering b) First Floor

257

419

107855.19

... More
code441 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

334

352

117878.62

... More
code442 - Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. Plaster mesh 100mm wide a) Ground Floor

406

38

15460.48

... More
code443 - Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. Plaster mesh 100mm wide b) First Floor

500

38

19230

... More
code444 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (a) Ground Floor

561

112

62832

... More
code445 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. b) First Floor

555.5

113

62838.16

... More
code446 - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. a) Ground Floor

561

182

102416.16

... More
code447 - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. b) First Floor

555.5

184

102423.09

... More
code448 - Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. & Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

312.5

159

49700

... More
code449 - Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. & Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. b) First Floor

257

160

41281.91

... More
code450 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. a) Ground Floor

82

128

10561.6

... More
code451 - Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

36.5

154

5641.44

... More
code452 - Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m

41

271

11112.64

... More
code453 - Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m

42

290

12183.36

... More
code454 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

27

297

8043.84

... More
code455 - Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work

56

95

5331.2

... More
code456 - Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates

3

6343

19031.04

... More
code457 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (Rate is inclusive of Shuttering) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

17.5

7096

124185.6

... More
code458 - Shuttering Work for combined Footing @8%

5.8

212

1234.24

... More
code459 - Shuttering Work for retaining wall @10%

8.4

709

5960.892

... More
code460 - Shuttering Work for Form Work for Slab@50%

2.9

3548

10289.664

... More
code461 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a) Ground Floor

1.7

100191

170326.128

... More
code462 - Food Graded Water Proofing Membrane Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification.

56

567

31799.04

... More
code463 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates a) Ground Floor

1.5

6992

10488.24

... More
code464 - Supplying and fixing of heavy duty SFRC manhole cover with frame 560MM size for underground tank.

1

5500

5500

... More
code465 - Providing and fixing of PVC Rungs footrest in under ground tanks / manhole using M20 concrete bed blocks for masonry walls or during construction for RCC surfaces, including cost of materials, labour, curing etc., complete as per specifications.

6

300

1800

... More
code466 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap a) Ground Floor

4

2626

10505.6

... More
code467 - Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover,and cistern fittings, nuts, bolts and gasket etc complete. a) Ground Floor

1

12570

12570.88

... More
code468 - Providing and fixing CP. Health faucet with flexible hose,CP Bibcock with 2 in 1 connectvity, wall flange, supporting hook with screws, fixing materials and sealant to all sides of wall flange complete. Make :

1

3000

3000

... More
code469 - Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.

4

812

3248

... More
code470 - Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931

14

711

9956.8

... More
code471 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

4

1366

5465.6

... More
code472 - Supplying , shifting to the place of installation and fixing testing and commissioning of stainless steel soap dish 150 x 150mm including cutting and setting in walls with cement joints and making good the wall. Make : JAQUAR Model No- ACN -1131N

10

834

8340

... More
code473 - Providing and fixing 2 in 1 Wall Mixer with complete fitting comprising of with provision for with long bend spout for bucket with wall flange complete.

1

5580

5580

... More
code474 - Providing and fixing shower head Arm with rose long bend free flow with fitting wall flange complete, including teflon with fixing.

1

2616

2616

... More
code475 - 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.

1

555

555.52

... More
code476 - Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm

2

6292

12584.32

... More
code477 - Supplying & fixing of CP sink mixer with swivel spout with wall flange etc complete. Make : Jaquar Model No- F-5347D

2

3060

6120

... More
code478 - Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm Dia

6

103

618.18

... More
code479 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 75mm dia., 6 kg/sqcm & class 3

20

246

4928

... More
code480 - Supply and delivery at site special moulded variety 75 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

5

75

375.15

... More
code481 - Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

5

215

1075.2

... More
code482 - Supply and delivery at site special moulded variety 75 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

3

131

393.12

... More
code483 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3

20

460

9206.4

... More
code484 - Supply and delivery at site special moulded variety 110 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

5

191

957.6

... More
code485 - Supply and delivery at site special moulded variety 110 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

5

338

1691.2

... More
code486 - Supply and delivery at site special moulded variety 110 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

5

281

1405.6

... More
code487 - Providing & fixing, testing and commissioning u PVC multi inlet floor trap 75mm dia conforming to IS 13592 with required P C C support placed to required level as per site condition complete..

8

552

4416

... More
code488 - Supplying and fixing PVC P' trap 110mm dia, of self cleansing design with or without vent arm complete including cutting and making good the walls and floors.

2

732

1464

... More
code489 - Providing & Fixing in position heavy duty C P grating 125mm dia, with frame of below mentioned sizes including jointing and fixing material complete.

9

282

2538

... More
code490 - Providing and grouting sleeves made in beam/ slab to draw waste and soil lines at all floor level of the below mentioned sizes , including condcting water ponding test to ensure zero leakage with all leads and lifts complete Size : 150 mm dia

4

720

2880

... More
code491 - Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete,As per direction of engineer in charge Concealed work including cutting chases and good the walls etc. 20 mm dia pipe nominal OD pipes

40

424

16979.2

... More
code492 - Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete,As per direction of engineer in charge Concealed work including cutting chases and good the walls etc. 25 mm dia pipe nominal OD pipes

5

534

2671.2

... More
code493 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :20 mm nominal bore.

2

351

703.36

... More
code494 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

1

614

614.88

... More
code495 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm dia pipe nominal OD pipes

18

243

4374.72

... More
code496 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia pipe nominal OD pipes

10

331

3315.2

... More
code497 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm dia pipe nominal OD pipes

24

416

9999.36

... More
code498 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 40 mm dia pipe nominal OD pipes

40

534

21369.6

... More
code499 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia pipe nominal OD pipes

20

807

16150.4

... More
code500 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :20 mm nominal bore.

4

351

1406.72

... More
code501 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25 mm nominal bore.

4

614

2459.52

... More
code502 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

4

669

2679.04

... More
code503 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

2

786

1572.48

... More
code504 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

2

957

1915.2

... More
code505 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

1000

10

10080

... More
code506 - Supplying & fixing suction Y'/ pot stainer with MS flange of suitable length fabricated from 16 gauge brass sheet with 3mm slots. 50 mm dia

2

4344

8688

... More
code507 - Supplying , fixing, testing and commissioning of PVC welded rain water head / khurras dome type grating with puddle flange to fix head in RCC slab specially fabricated from minimum 4mm thick PVC sheet, including removable heavy duty PVC grating of 50 x 3 mm thick PVC flats (Round or Square) as per approved design The quoted rate shall include for necessary grouting the khurras base with approved sealant complete all as shown in the drawing and as specified. 150 x 150mm PVC Grating

4

830

3320

... More
code508 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 75mm dia., 6 kg/sqcm & class 3

48

246

11827.2

... More
code509 - Supply and delivery at site special moulded variety 75 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

10

75

750.3

... More
code510 - Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

10

215

2150.4

... More
code511 - Supply and delivery at site special moulded variety 75 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

10

131

1310.4

... More
code512 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 a) Ground Floor

69

460

31762.08

... More
code513 - Supply and delivery at site special moulded variety 110 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

10

191

1915.2

... More
code514 - Supply and delivery at site special moulded variety 110 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

10

338

3382.4

... More
code515 - Supply and delivery at site special moulded variety 110 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

10

281

2811.2

... More
code516 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 160mm dia., 6 kg/sqcm & class 3

16

692

11074.56

... More
code517 - Supply and delivery at site special moulded variety 160 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

6

375

2251.2

... More
code518 - Supply and delivery at site special moulded variety 160 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

6

527

3165.12

... More
code519 - Supply and delivery at site special moulded variety 160 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

9

521

4697.28

... More
code520 - Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete

4

387

1550.08

... More
code521 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover

4

6108

24433.92

... More
code522 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m

38.55

542

20897.184

... More
code523 - DOMESTIC WATER TRANSFAR PUMP Supplying, installing, testing and commissioning of submersible / Mono blockelectrical driven pump 1set . (1 working & standby) domestic water pumps for pumping domestic water from U.G. sump to over head water tank, with all necessary arrangements to operate on 3HP 50 HZ, 440V AC supply fitted on a common base frame accessories to lift the pump during maintenance , necessary power connections, the supplier shall include the control panel and wiring from TPN switch to control panel and wiring upto pumps, the control panel comprising of O/L relays, single phase preventor,separate overload trip and relayset, ON/OFF/TRIP indicating lamps,start/stop push buttons, With liquid level controlers, etc., complete as complete. Duty of the Pump 4 cum per hour at 20 TO 25 m head Make : Kirloskar/ suguna/texmo/CRI two set industrial type electronic automatic liquid level controllers, with stainless steel probes / sensors.

1

24000

24000

... More
code524 - Providing and fixing gun metal non- return valve of approved quality (screwed end) 32 mm nominal bore Vertical

2

1036

2072

... More
code525 - Providing and fixing gun metal non- return valve of approved quality (screwed end) 40 mm nominal bore Vertical

2

1372

2744

... More
code526 - Construction of brick masonry catch basin chamber chambers of internal clear dimension as mentioned below by using first class table moulded modular bricks 230 mm thick wall in cement mortor joints in 1:4, over CC 1:4:8 bed 150 mm thick including Supplying precast RCC perforated top slab in 1:2:4 Mix (1 cement: 2 coarse coarse sand: 8 graded stone aggregate), with angle iron frame, inside plastering15mm thick with CM 1:3 (1 cement::3 fine sand) finished very smooth with floating coat of neat cement & making benching and channelling in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 gradedstone aggregate) neatly finished complete as per standard design and as per drawing and specifications.Inside size of 600 x 600mm & depth not exceeding 600 x 600mm including Supplying 450 x 450mm RCC cover with MS L angle frame.

2

6920

13840.8

... More
code527 - Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. 32 mm dia

1

696

696

... More
code528 - Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. 40 mm dia

1

828

828

... More
code529 - Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. 50 mm dia

1

1044

1044

... More
code530 - Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. 65 mm dia

1

1398

1398

... More
code531 - LT ELECTRICAL WORKS PVC CONDUITS & ITS ACCESSORIES Open conduit System Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. a) 19/20 mm dia 2mm thick

50

69

3450

... More
code532 - Open conduit System Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. b) 25mm dia 2mm thick

100

81

8100

... More
code533 - Open conduit System Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. c) 32mm dia 2.5mm thick

50

106

5300

... More
code534 - Concealed conduit System Supplying heavy gauge PVC conduit pipe ……mm dia ......mm thick confirming to IS 2509 with suitable size bends, metals/PVC junction boxes, adhesives paste etc., and running before concreting the slab . The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. a) 19/20 mm dia 2mm thick

200

66

13200

... More
code535 - Concealed conduit System Supplying heavy gauge PVC conduit pipe ……mm dia ......mm thick confirming to IS 2509 with suitable size bends, metals/PVC junction boxes, adhesives paste etc., and running before concreting the slab . The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. b) 25mm dia 2mm thick

700

78

54600

... More
code536 - Concealed conduit System Supplying heavy gauge PVC conduit pipe ……mm dia ......mm thick confirming to IS 2509 with suitable size bends, metals/PVC junction boxes, adhesives paste etc., and running before concreting the slab . The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. c) 32mm dia 2.5mm thick

50

103

5150

... More
code537 - Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc. By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary a) 19/20 mm dia 2mm thick

20

68

1360

... More
code538 - Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc. By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary b) 25mm dia 2mm thick

40

79

3160

... More
code539 - Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc. By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary c) 32mm dia 2.5mm thick

10

99

990

... More
code540 - Supplying and fixing PVC/metal conduit deep junction box. a) 19/20mm deep junction box

20

49

980

... More
code541 - Supplying and fixing PVC/metal conduit deep junction box. b) 25mm deep junction box

30

56

1680

... More
code542 - Supplying and fixing PVC/metal conduit deep junction box. c) 32mm deep junction box

10

61

610

... More
code543 - Extra for Groove cutting in brick wall/cc floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing the wall upto wall surface complete. a) upto 50mm conduit in CC Floor

50

69

3450

... More
code544 - Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm..using NF screws and on either end of the pipe terminated completely. a) 25 mm

50

22

1100

... More
code545 - Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm..using NF screws and on either end of the pipe terminated completely. b) 32 mm

20

29

580

... More
code546 - Supplying and fixing Metal fan box with round hook.

15

117

1755

... More
code547 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. a) Short point up to 3Mtr from tapping point to out let via switch box

15

269

4035

... More
code548 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. b) Medium point above 3Mtr up to 6Mtrs from tapping point to out let via switch box

20

379

7580

... More
code549 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box

30

555

16650

... More
code550 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. d) Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switch box

15

677

10155

... More
code551 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. e) Three outlet in a row, above 6Mtr up to 10Mtr from tapping point to out let via switches box

5

989

4945

... More
code552 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. a) 1.5 sqmm

300

26

7800

... More
code553 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. b) 2.5 sqmm

1500

42

63000

... More
code554 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. c) 4 sqmm

800

63

50400

... More
code555 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. d) 6 sqmm

100

92

9200

... More
code556 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. e) 10 sqmm

100

167

16700

... More
code557 - Supplying and Drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130-1984 and (virgin) PVC insulation and sheathed suitable for working voltage upto 1100volts as per IS-694:1990. a) 3Cx2.5Sqmm

50

113

5650

... More
code558 - Supplying and Drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130-1984 and (virgin) PVC insulation and sheathed suitable for working voltage upto 1100volts as per IS-694:1990. b) 3Cx4.0Sqmm

50

172

8600

... More
code559 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall a) 1-2 Way

5

138

690

... More
code560 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall b) 3 Way

15

159

2385

... More
code561 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall c) 4 Way

5

177

885

... More
code562 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall d) 6 Way

25

220

5500

... More
code563 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall e) 8 Way

15

261

3915

... More
code564 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall f) 10-12 Way

5

319

1595

... More
code565 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall g) 16 Way

3

363

1089

... More
code566 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall h) 18 Way

2

405

810

... More
code567 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. a) 1 to 2 Module

5

137

685

... More
code568 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. b) 3 Module

15

161

2415

... More
code569 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. c) 4 Module

5

175

875

... More
code570 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. d) 6 Module

25

234

5850

... More
code571 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. e) 8 Module

15

284

4260

... More
code572 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. f) 10-12 Module

5

344

1720

... More
code573 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. g) 16 Module

3

397

1191

... More
code574 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. h) 18 Module

2

457

914

... More
code575 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 a) 6 Amps one way

100

102

10200

... More
code576 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 b) 6 Amps Two way

4

166

664

... More
code577 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 c) 6Amps 3way socket.

15

171

2565

... More
code578 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 d) Stepped fan regulator

15

357

5355

... More
code579 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 e) 32A,DP,Switch

5

326

1630

... More
code580 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 f) 16Amps one way switch

15

180

2700

... More
code581 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 g) 6/16Amps universal socket

20

236

4720

... More
code582 - CONTROL SWITCH GEARS & ACCESSORIES Supplying push button operated, direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 400/440 volts 3 phase motor/single phase motor upto 5 HP.

2

1927

3854

... More
code583 - Supplying and fixing regular MCB distributionpanel confirming to IS 8828 , on wall/wood board/ flush mounting using required clamps, bolts, nuts etc.. With provision for fixing of suitable type capacity ELMCB / MCb's as an incomer for 3 phase double door with necessary bus bar completely wired to use on 440volts 3 phase 4 wired powder coated painting etc.. complete with provision for fixing of single/three phase suitable capacity ELMCB/MCb's as outgoings confirming to IS8828 . 8 way

1

12605

12605

... More
code584 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. a) 5-32Amps SP

36

415

14940

... More
code585 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. b) 5-32Amps DP

6

739

4434

... More
code586 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. c) 5-32Amps TPN

16

1717

27472

... More
code587 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. d) 40Amps TPN

2

3044

6088

... More
code588 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure a) Double Door 4 Way SP & N

1

1524

1524

... More
code589 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure b) Double Door 16 Way SP & N

1

2908

2908

... More
code590 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure c) Double Door 4 Way TP & N

1

4038

4038

... More
code591 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure d) Double Door 6 Way TP & N

1

4940

4940

... More
code592 - Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/ panel board. a) 32-40Amps 4 pole

1

5147

5147

... More
code593 - Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/ panel board. b) 63Amps 4 pole

2

5545

11090

... More
code594 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron ….and M.S. flat with bolts, washers etc… and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6

20

305

6100

... More
code595 - Supplying and fixing of metal Socket set of 2 pole and earth plugs and socket for incorporating SP and TP MCB (without MCB). The entire Plug and Socket shall be mounted in athermoplastic / powder coated metal box & wired completely. SP & N 20Amps

4

971

3884

... More
code596 - Supplying and fixing of metal Socket set of 2 pole and earth plugs and socket for incorporating SP and TP MCB (without MCB). The entire Plug and Socket shall be mounted in athermoplastic / powder coated metal box & wired completely. TP & N 30Amps

4

1700

6800

... More
code597 - EARTHING AND L.T. U.G. CABLES Supplying fixing and wiring earth electrode for grounding of DG Sets etc. using 40mm dia 2.9mm thick 2.5mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.

4

4256

17024

... More
code598 - Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. a) GI strip 25x3mm

100

82

8200

... More
code599 - Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. b) GI strip 25x6mm

30

128

3840

... More
code600 - Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. c) CU strip 25x3mm

10

570

5700

... More
code601 - Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. d) 600x600x3mm GI Plate

2

875

1750

... More
code602 - Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. e) 600x600x3mm CU Plate

2

7421

14842

... More
code603 - Supplying, Fixing & proper termination of vertical Air-termination using Gunmetal ball with finials of 5 spikes mounted on 2 mtrs long copper rod, mounted at the highest point of the building, with base plates, connection with horizontal conductor, necessary civil works, etc.

1

7500

7500

... More
code604 - Supply & fixing Test Link as per specification & drgs. and grouted to wall at 1200 mm. above ground level complete with all fixing accessories, clamps, screws etc, enclosed in M.S box.

1

3500

3500

... More
code605 - Supplying & Fixing Chemical earthing for grounding, conduits, IC cut outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10 ft copper bonded rod with backfill compound

2

8494

16988

... More
code606 - Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.. 8 SWG GI wire.

0.1

75040

7504

... More
code607 - Supplying of 1.1KV LT UG Aluminium cable XLPE insulated, PVC extruded inner sheathed, armourd UG LT cable as per the IS - 1554 (part-1) or IS-7098 part-1, Armoring strip thickness in average + 5% and resistivity 14 Ohms/Kms (Max) as per IS -3975. b) 4 core 10 sq.mm

0.05

118004

5900.2

... More
code608 - Supplying of 1.1KV LT UG Aluminium cable XLPE insulated, PVC extruded inner sheathed, armourd UG LT cable as per the IS - 1554 (part-1) or IS-7098 part-1, Armoring strip thickness in average + 5% and resistivity 14 Ohms/Kms (Max) as per IS -3975. c) 4 core 16 sq.mm

0.1

141842

14184.2

... More
code609 - Supplying of 1.1KV LT UG Aluminium cable XLPE insulated, PVC extruded inner sheathed, armourd UG LT cable as per the IS - 1554 (part-1) or IS-7098 part-1, Armoring strip thickness in average + 5% and resistivity 14 Ohms/Kms (Max) as per IS -3975. d) 3.5 core 70 sq.mm

0.1

317912

31791.2

... More
code610 - Labour charges for laying of 1.1 KV class UG cable in the existing trench GI pipe / stoneware pipe / on wall / on pole as required. On wall / Structure. a) 2.5 sqmm to 25 sqmm

0.15

20886

3132.9

... More
code611 - Labour charges for laying of 1.1 KV class UG cable in the existing trench GI pipe / stoneware pipe / on wall / on pole as required. On wall / Structure. b) 35 sqmm to 95 sqmm

0.1

31139

3113.9

... More
code612 - Supplying and fixing of heavy duty cable glands suitable for UG cable of1.1 KV class (metal only) a) 25mm

6

79

474

... More
code613 - Supplying and fixing of heavy duty cable glands suitable for UG cable of1.1 KV class (metal only) b) 32mm

4

95

380

... More
code614 - Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. a) 150x50mm

10

463

4630

... More
code615 - Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. b) 300x50mm

5

587

2935

... More
code616 - Aluminium End Terminal (Lug) a) 6 / 10 sq.mm

80

2

160

... More
code617 - Aluminium End Terminal (Lug) b) 16 sq.mm

10

2

20

... More
code618 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. a) 70 sq.mm Long barrel

10

89

890

... More
code619 - FANS Supplying exhaust fan of 1440RPM heavy duty with bracket blades complete for lighting duty suitable to operate on 230V 50Hz, AC supply.. 12" sweep (300mm)

10

2969

29690

... More
code620 - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 10% RPM, Rated air delivery 210 10% Cubic Meter Minimum, Rated service value 4.2 CMM / Watt, Three Blades of blade leaf 1.05 mm thick

15

2677

40155

... More
code621 - Supplying wall mounting fan suitable to operate at single phase 230v AC supply. 400mm Sweep

5

3212

16060

... More
code622 - Fixing all types and all capacities fluorescent /false ceiling/spot light/CFL/LED fittings indoor on the wall / ceiling / rafters / girders using 23 / 0.00076 " twin twisted PVC insulated wires, required nos of round blocks and clamps. On wall / ceiling / Rafters / Girders

110

122

13420

... More
code623 - Using 2 Mtr long 19mm 18SWG enamelled braised conduit of two nos. rod pendent with ball socket with check nuts all nickel painted.

30

570

17100

... More
code624 - Extra length of GI pipe of class b 19mm dia for down rod.

30

197

5910

... More
code625 - Fixing a ceiling/wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing a 5 amps ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.

20

315

6300

... More
code626 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.

10

492

4920

... More
code627 - LED LUMINAIRS / LIGHT FIXTURES & ACCESSORIES Supplying and fixing of LED Bulk head of 10Wwith IP65 protection and IK08 impact resistance suitable for surfaceandwallmounting applications.

5

842

4210

... More
code628 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. a) Led light fitting 2' - 9 / 10 watts

5

551

2755

... More
code629 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. b) Led light fitting 4' - 20 / 22 watts

10

690

6900

... More
code630 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. c) Led light fitting 2 X 4' - 20 / 22 watts

30

1269

38070

... More
code631 - Supplying of Surface / recess mounting non integrated type LED down light …W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power / COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit THD Less then 20%, Life as per LM 79, The operating input voltage should be between 130 to 275 volts, BIS Approved and tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 10-12W

10

885

8850

... More
code632 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ umileds/Osram make LED Source. 70-80W FLOOD LED LIGHT

4

6768

27072

... More
code633 - Design, manufacture, supplying, fixing in position, testing and commissioning of following MV switchgear panels made up of 14/16G, suitable for 415 V, 3 phase, 4 wire, 50 Hz power distribution system. The incoming and outgoing feeders shall be accommodated in a modular multitier arrangement and shall be interlocked to avoid paralleling, adequate size cable alley, painting, earthing, numbering, danger plate etc. as required as per specifications and drawings. The panels should be with all items as per SLD and Specification. c) Supply, installation, testing & commissioning of MAIN POSTMORTEM HOUSE EB,DG AUTO CHANGEOVER PANEL- AS PER SLD suitable for 415 V, 3 ph, 4 wire, 50 Hz, power distribution system as per Single Line Diagram.

1

125000

125000

... More
code634 - Supplying, erecting, testing & commissioning of ONLINE UPS System suitable for operation on 230V, 50Hz, A/C supply with isolation transformer all accessories complete and Excluding batteries and wiring complete 3 KVA ONLINE UPS

1

38719

38719

... More
code635 - Supplying, installation, testing & commissioning of 12volts DC AH Batteries in poly propylene container for UPS Low maintenance Tubular/smf batteries. 12V, 75-80 AH Capacity. Acid battery.

4

10172

40688

... More
code636 - CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 1/3" progressive scan CMOS, 4.0 megapixel, IP based Colour camera, with 3-12mm verifocal lens, Up to 30 m IR range, Color: 0.01Lux, 1000TVL, Digital WDR (Wide Dynamic Range), 3D DNR (Digital Noise Reduction), PoE (Power over Ethernet/1 RJ45 10M/100M self-adaptive Ethernet port), IP67, Motion detection, Alarms (Video tampering, network disconnected, IP address conflicted), Protocols (TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, RTCP, NTP, UPnP, SMTP, IGMP, 802.1X, QoS, IPv6, Bonjour), Standard (ONVIF(PROFILE S,PROFILE G),PSIA,CGI,ISAPI), General Function (Anti-flicker, heartbeat, mirror, password protection, privacy mask, watermark), with base box, other necessary accessories. The cost shall includes end terminations.

6

11250

67500

... More
code637 - Supply, Installation, Testing & Commissioning of 8port 10/100/1000 Smart POE Switch with 4 SFP (192W)for camera connection including all necessary accessories.

1

7500

7500

... More
code638 - Supply, Installation, Testing & Commissioning of NVR (Networkable Video Recorder) - 8Channel NVR, Up to 8ch IP cameras input, Up to 5 Megapixels resolution recording HDMI and VGA output at up to 1920 1080P resolution, HDD quota and group management 4 SATA, 3 USB, interface, 1 RJ-45 10 /100 /1000 Mbps self-adaptive Ethernet interface

1

20000

20000

... More
code639 - Supply, Installation, Testing & Commissioning of HDMI, Display Monitor 32" high resolution, Monitor with all mounting bracket accessories.

1

32000

32000

... More
code640 - Supply, laying and termination of CAT6 UTP, cable for IP BASED Camera power and video connection in existing Conduit / pipe.

200

34

6800

... More
code641 - NETWORKING AND COMMUNICATION : Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. a) TV/ Telephone socket

5

156

780

... More
code642 - NETWORKING AND COMMUNICATION : Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. b) RJ45/I.O. outlet

5

337

1685

... More
code643 - Supplying and drawing UTP-CAT 6 LAN cable.

150

38

5700

... More
code644 - Supplying and Drawing PVC flexible one pair telephone unarmoured tinned copper cable. a) 2 Pair

50

21

1050

... More
code645 - Supplying and Drawing PVC flexible one pair telephone unarmoured tinned copper cable. b) 5 Pair

100

46

4600

... More
code646 - Supplying and Drawing PVC flexible one pair telephone unarmoured tinned copper cable. c) 20 Pair

30

150

4500

... More
code647 - Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable. RG-6.

50

44

2200

... More
code648 - Supplying and fixing of switch mounting rack with power manager & cable manager. 6U with 450mm depth

1

6977

6977

... More
code649 - Supplying and fixing of power strip.

1

1457

1457

... More
code650 - Supplying and fixing of fan.

1

1209

1209

... More
code651 - Supplying fixing of Network Switches. 10 Port Gigabyte manageable

1

20200

20200

... More
code652 - Supplying & fixing of ….mtrs Cat6 Patch Cable - a) 1 mtr

5

224

1120

... More
code653 - b) 2 mtr

5

257

1285

... More
code654 - Supplying & fixing of Patch Panel for LAN cabling. 16 Port 10/100/1000 Patch Panel

1

7750

7750

... More
code655 - Supplying and Fixing of MDF Krone junction box with KRONE module / Telephone cable termination. 30 pair

1

568

568

... More
code656 - Supply and laying 6 Core Multimode OM3 outdoor Fiber Cable.

150

250

37500

... More
code657 - Supply and providing 12F, 1U, LC MM OM3, Loaded with Pigtails, Splice tray, adapter & splice protectors

1

12500

12500

... More
code658 - Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Manual Means a) In area of light jungle

5

1256

6283.15

... More
code659 - Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.. In all kinds of soils upto 300 mm depth

349

106

37133.6

... More
code660 - Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m

322

271

87274.88

... More
code661 - Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m

119

290

34519.52

... More
code662 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

88.2

297

26276.544

... More
code663 - Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work

353.2

95

33624.64

... More
code664 - Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work.

367

530

194832.96

... More
code665 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.

349

132

46123.84

... More
code666 - Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates

43

6343

272778.24

... More
code667 - Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates

9

6963

62667.36

... More
code668 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates b) Terrace Floor

3

7032

21098.01

... More
code669 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (Rate is inclusive of Shuttering) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

76

7096

539320.32

... More
code670 - Shuttering work fpr Isolated Footing @8%

34.64

567

19665.128

... More
code671 - Shuttering Work for Combined Footing @3%

11.4975

212

2447.5878

... More
code672 - Shuttering Work for Pedestals @70%

8.8335

4967

43879.70457

... More
code673 - Shuttering Work for Columns Upto Plinth Beam @70%

7.08

4967

35169.3336

... More
code674 - Shuttering Work for Plinth Beam @50%

13.34

3548

47332.4544

... More
code675 - Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates

13

7257

94348.8

... More
code676 - Shuttering Work for Wall@ 10%

13

725

9434.88

... More
code677 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Rate is inclusive of Shuttering) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

68

7664

521162.88

... More
code678 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Rate is inclusive of Shuttering) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates b) Terrace Floor

31

7740

239964.8

... More
code679 - Shuttering Work for Columns @ 70%- Ground Floor

15.93

5364

85463.0163

... More
code680 - Shuttering Work for Columns @ 70%- Terrace Floor

2.26

5418

12245.9456

... More
code681 - Shuttering Work for Roof Beam, Lintel Beam @ 60%-Ground Floor

17.9657

4598

82615.091793

... More
code682 - Shuttering Work for Roof Beam, Lintel Beam @ 60%-First Floor

9.72

4644

45144.3456

... More
code683 - Shuttering Work for Roof Slab @ 50%- Ground Floor

32.86

3832

125922.1488

... More
code684 - Shuttering Work for Roof Slab @ 50%- First Floor

18.6945

3870

72355.1928

... More
code685 - Shuttering Work for Chajja @ 45% Ground Floor

1.23

3448

4242.1101

... More
code686 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a) Ground Floor

15.56

100191

1558985.0304

... More
code687 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. b) Terrace Floor

3.61

101193

365309.4375

... More
code688 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. a) Ground Floor

375

1467

550200

... More
code689 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. b) Terrace Floor

60

1481

88912.2

... More
code690 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. a) Ground floor

38

1236

46986.24

... More
code691 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. a) Ground Floor

803

204

164582.88

... More
code692 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. b) Terrace Floor

279

207

57753

... More
code693 - Providing & fixing of 2.5 track 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced

18

7337

132068.16

... More
code694 - Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.

16

7542

120673.28

... More
code695 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) a)Ground Floor

6

6405

38431.68

... More
code696 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm 39mm with GI reinforcement of 1mm thickness

16

6469

103509.28

... More
code697 - Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

176

154

27202.56

... More
code698 - Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.

9

2948

26540.64

... More
code699 - Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.

1162

152

176995.84

... More
code700 - Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.

0.7

154642

108250.016

... More
code701 - Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )

4.5

8337

37517.76

... More
code702 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.. -do- 35 mm thick both side commercial

29.5

3720

109758.88

... More
code703 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 150mm

21

903

18980.64

... More
code704 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 35 mm thickness

7

4525

31681.44

... More
code705 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.

14

1137

15930.88

... More
code706 - Providing and fixing SS 304 Aldrop-250mm x 16mm (variation in size acceptable upto + / - 10%) suitable for door shutters including SS screws cost of materials, labour etc., complete as per specifications of vendor details. Make: Dorset / Godrej / Niell / Archis / Kadson / AKS / equivalent Model as per Specification.

10

1910

19100

... More
code707 - Providing and fixing Stainless Steel(304 grade) Cylindrical lock with key to door shutters including cost of materials, labour etc., complete as per specifications of vendor and as per architects details. Make - Dorset / Equivalent Approved Model

10

1075

10752

... More
code708 - Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete

42

265

11148.48

... More
code709 - Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete a) Ground Floor

17

264

4493.44

... More
code710 - Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 25x85x5.5 mm (heavy type) a) Ground Floor

63

308

19404

... More
code711 - Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete

43

145

6260.8

... More
code712 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Aldrop 16mm dia, 200mm No

8

336

2688

... More
code713 - Providing and fixing MS Holdfast of size 260mm x 25mm x 5mm thk for fixing door frame to walls including cost of materials, cutting masonry pockets for receiving MS Holdfast, one coat of shop primer , concrete filling of pockets, disposal of debris, keeping the area clean, curing, labour etc., complete as per specifications of vendor and as per architects details.

60

40

2400

... More
code714 - Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. b) Terrace Floor

346

924

319769.74

... More
code715 - Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates b) Terrace Floor

24

7032

168784.08

... More
code716 - Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent..

56

2761

154667.52

... More
code717 - Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.

77

367

28286.72

... More
code718 - Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm

70

1316

92120

... More
code719 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.

59

995

58745.12

... More
code720 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.

314

1622

509584.32

... More
code721 - Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.

154

1730

266481.6

... More
code722 - Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.

7

4792

33547.36

... More
code723 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal wall plastering a) Ground Floor

395

312

123429.6

... More
code724 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal wall plastering b) Terrace Floor

51

315

16095.6

... More
code725 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Rough plastering a) Ground Floor

314

330

103745.6

... More
code726 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Plastering a) Ground Floor

321

415

133381.92

... More
code727 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Plastering b) Terrace Floor

153

419

64209.51

... More
code728 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

214

349

74780.16

... More
code729 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. b) Terrace Floor

127

352

44822.11

... More
code730 - Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. Plaster mesh 100mm wide a) Ground Floor

450

38

17136

... More
code731 - Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. Plaster mesh 100mm wide b) Terrace Floor

177

38

6807.42

... More
code732 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (a) Ground Floor

609

112

68208

... More
code733 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. b) Terrace Floor

178

113

20135.36

... More
code734 - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. a) Ground Floor

609

182

111179.04

... More
code735 - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. b) Terrace Floor

178

184

32819.64

... More
code736 - Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. & Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

321

159

51051.84

... More
code737 - Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. & Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. b) Terrace Floor

153

160

24576.39

... More
code738 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. a) Ground Floor

99

128

12751.2

... More
code739 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. b) Terrace Floor

14

130

1821.12

... More
code740 - Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

25

154

3864

... More
code741 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap a) Ground Floor

4

2626

10505.6

... More
code742 - Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover,and cistern fittings, nuts, bolts and gasket etc complete. a) Ground Floor

1

12570

12570.88

... More
code743 - Providing and fixing CP. Health faucet with flexible hose,CP Bibcock with 2 in 1 connectvity, wall flange, supporting hook with screws, fixing materials and sealant to all sides of wall flange complete. Make :

1

3000

3000

... More
code744 - Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.

6

812

4872

... More
code745 - Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931

6

711

4267.2

... More
code746 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

4

1366

5465.6

... More
code747 - Supplying , shifting to the place of installation and fixing testing and commissioning of stainless steel soap dish 150 x 150mm including cutting and setting in walls with cement joints and making good the wall. Make : JAQUAR Model No- ACN -1131N

4

834

3336

... More
code748 - Providing and fixing 2 in 1 Wall Mixer with complete fitting comprising of with provision for with long bend spout for bucket with wall flange complete.

1

5580

5580

... More
code749 - Providing and fixing shower head Arm with rose long bend free flow with fitting wall flange complete, including teflon with fixing.

1

2616

2616

... More
code750 - 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.

1

555

555.52

... More
code751 - Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm Dia

11.2

103

1153.936

... More
code752 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 75mm dia., 6 kg/sqcm & class 3

15

246

3696

... More
code753 - Supply and delivery at site special moulded variety 75 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

3

75

225.09

... More
code754 - Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

3

215

645.12

... More
code755 - Supply and delivery at site special moulded variety 75 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

3

131

393.12

... More
code756 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3

10

460

4603.2

... More
code757 - Supply and delivery at site special moulded variety 110 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

2

191

383.04

... More
code758 - Supply and delivery at site special moulded variety 110 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

2

338

676.48

... More
code759 - Supply and delivery at site special moulded variety 110 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

2

281

562.24

... More
code760 - Providing & fixing, testing and commissioning u PVC multi inlet floor trap 75mm dia conforming to IS 13592 with required P C C support placed to required level as per site condition complete..

6

552

3312

... More
code761 - Supplying and fixing PVC P' trap 110mm dia, of self cleansing design with or without vent arm complete including cutting and making good the walls and floors.

2

732

1464

... More
code762 - Providing & Fixing in position heavy duty C P grating 125mm dia, with frame of below mentioned sizes including jointing and fixing material complete.

8

282

2256

... More
code763 - Providing and grouting sleeves made in beam/ slab to draw waste and soil lines at all floor level of the below mentioned sizes , including condcting water ponding test to ensure zero leakage with all leads and lifts complete Size : 150 mm dia

4

720

2880

... More
code764 - Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete,As per direction of engineer in charge Concealed work including cutting chases and good the walls etc. 20 mm dia pipe nominal OD pipes

50

424

21224

... More
code765 - Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete,As per direction of engineer in charge Concealed work including cutting chases and good the walls etc. 25 mm dia pipe nominal OD pipes

30

534

16027.2

... More
code766 - Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :

2

351

703.36

... More
code767 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

1

614

614.88

... More
code768 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm dia pipe nominal OD pipes

40

243

9721.6

... More
code769 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia pipe nominal OD pipes

15

331

4972.8

... More
code770 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm dia pipe nominal OD pipes

44

416

18332.16

... More
code771 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 40 mm dia pipe nominal OD pipes

40

534

21369.6

... More
code772 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia pipe nominal OD pipes

20

807

16150.4

... More
code773 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :20 mm nominal bore.

4

351

1406.72

... More
code774 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25 mm nominal bore.

4

614

2459.52

... More
code775 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

4

669

2679.04

... More
code776 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

2

786

1572.48

... More
code777 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

2

957

1915.2

... More
code778 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

2000

10

20160

... More
code779 - Supplying & fixing suction Y'/ pot stainer with MS flange of suitable length fabricated from 16 gauge brass sheet with 3mm slots. 50 mm dia

2

4344

8688

... More
code780 - Supplying , fixing, testing and commissioning of PVC welded rain water head / khurras dome type grating with puddle flange to fix head in RCC slab specially fabricated from minimum 4mm thick PVC sheet, including removable heavy duty PVC grating of 50 x 3 mm thick PVC flats (Round or Square) as per approved design The quoted rate shall include for necessary grouting the khurras base with approved sealant complete all as shown in the drawing and as specified. 150 x 150mm PVC Grating

4

830

3320

... More
code781 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 75mm dia., 6 kg/sqcm & class 3

53

246

13059.2

... More
code782 - Supply and delivery at site special moulded variety 75 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

10

75

750.3

... More
code783 - Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

10

215

2150.4

... More
code784 - Supply and delivery at site special moulded variety 75 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

10

131

1310.4

... More
code785 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 a) Ground Floor

92

460

42349.44

... More
code786 - Supply and delivery at site special moulded variety 110 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

10

191

1915.2

... More
code787 - Supply and delivery at site special moulded variety 110 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

10

338

3382.4

... More
code788 - Supply and delivery at site special moulded variety 110 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

10

281

2811.2

... More
code789 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 160mm dia., 6 kg/sqcm & class 3

16

692

11074.56

... More
code790 - Supply and delivery at site special moulded variety 160 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

6

375

2251.2

... More
code791 - Supply and delivery at site special moulded variety 160 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

6

527

3165.12

... More
code792 - Supply and delivery at site special moulded variety 160 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

9

521

4697.28

... More
code793 - Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete

5

387

1937.6

... More
code794 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover

6

6108

36650.88

... More
code795 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m

55.65

542

30166.752

... More
code796 - DOMESTIC WATER TRANSFAR PUMP Supplying, installing, testing and commissioning of submersible / Mono blockelectrical driven pump 1set . (1 working & standby) domestic water pumps for pumping domestic water from U.G. sump to over head water tank, with all necessary arrangements to operate on 3HP 50 HZ, 440V AC supply fitted on a common base frame accessories to lift the pump during maintenance , necessary power connections, the supplier shall include the control panel and wiring from TPN switch to control panel and wiring upto pumps, the control panel comprising of O/L relays, single phase preventor,separate overload trip and relayset, ON/OFF/TRIP indicating lamps,start/stop push buttons, With liquid level controlers, etc., complete as complete. Duty of the Pump 4 cum per hour at 20 TO 25 m head Make : Kirloskar/ suguna/texmo/CRI two set industrial type electronic automatic liquid level controllers, with stainless steel probes / sensors.

2

24000

48000

... More
code797 - Providing and fixing gun metal non- return valve of approved quality (screwed end) 32 mm nominal bore Vertical

2

1036

2072

... More
code798 - Providing and fixing gun metal non- return valve of approved quality (screwed end) 40 mm nominal bore Vertical

2

1372

2744

... More
code799 - Construction of brick masonry catch basin chamber chambers of internal clear dimension as mentioned below by using first class table moulded modular bricks 230 mm thick wall in cement mortor joints in 1:4, over CC 1:4:8 bed 150 mm thick including Supplying precast RCC perforated top slab in 1:2:4 Mix (1 cement: 2 coarse coarse sand: 8 graded stone aggregate), with angle iron frame, inside plastering15mm thick with CM 1:3 (1 cement::3 fine sand) finished very smooth with floating coat of neat cement & making benching and channelling in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 gradedstone aggregate) neatly finished complete as per standard design and as per drawing and specifications.Inside size of 600 x 600mm & depth not exceeding 600 x 600mm including Supplying 450 x 450mm RCC cover with MS L angle frame.

2

6920

13840.8

... More
code800 - Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. 32 mm dia

1

696

696

... More
code801 - Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. 40 mm dia

1

828

828

... More
code802 - Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. 50 mm dia

1

1044

1044

... More
code803 - Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. 65 mm dia

1

1398

1398

... More
code804 - LT ELECTRICAL WORKS PVC CONDUITS & ITS ACCESSORIES Open conduit System Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. a) 19/20 mm dia 2mm thick

50

69

3450

... More
code805 - Open conduit System Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. b) 25mm dia 2mm thick

100

81

8100

... More
code806 - Open conduit System Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. c) 32mm dia 2.5mm thick

50

106

5300

... More
code807 - Concealed conduit System Supplying heavy gauge PVC conduit pipe ……mm dia ......mm thick confirming to IS 2509 with suitable size bends, metals/PVC junction boxes, adhesives paste etc., and running before concreting the slab . The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. a) 19/20 mm dia 2mm thick

250

66

16500

... More
code808 - Concealed conduit System Supplying heavy gauge PVC conduit pipe ……mm dia ......mm thick confirming to IS 2509 with suitable size bends, metals/PVC junction boxes, adhesives paste etc., and running before concreting the slab . The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. b) 25mm dia 2mm thick

800

78

62400

... More
code809 - Concealed conduit System Supplying heavy gauge PVC conduit pipe ……mm dia ......mm thick confirming to IS 2509 with suitable size bends, metals/PVC junction boxes, adhesives paste etc., and running before concreting the slab . The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. c) 32mm dia 2.5mm thick

50

103

5150

... More
code810 - Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc. By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary a) 19/20 mm dia 2mm thick

20

68

1360

... More
code811 - Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc. By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary b) 25mm dia 2mm thick

40

79

3160

... More
code812 - Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc. By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary c) 32mm dia 2.5mm thick

10

99

990

... More
code813 - Supplying and fixing PVC/metal conduit deep junction box. a) 19/20mm deep junction box

30

49

1470

... More
code814 - Supplying and fixing PVC/metal conduit deep junction box. b) 25mm deep junction box

60

56

3360

... More
code815 - Supplying and fixing PVC/metal conduit deep junction box. c) 32mm deep junction box

10

61

610

... More
code816 - Extra for Groove cutting in brick wall/cc floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing the wall upto wall surface complete. a) upto 50mm conduit in CC Floor

50

69

3450

... More
code817 - Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm..using NF screws and on either end of the pipe terminated completely. a) 25 mm

50

22

1100

... More
code818 - b) 32 mm

20

29

580

... More
code819 - Supplying and fixing Metal fan box with round hook.

15

117

1755

... More
code820 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. a) Short point up to 3Mtr from tapping point to out let via switch box

20

269

5380

... More
code821 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. b) Medium point above 3Mtr up to 6Mtrs from tapping point to out let via switch box

25

379

9475

... More
code822 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box

30

555

16650

... More
code823 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. d) Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switch box

15

677

10155

... More
code824 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. e) Three outlet in a row, above 6Mtr up to 10Mtr from tapping point to out let via switches box

5

989

4945

... More
code825 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments.a) 1.5 sqmm

300

26

7800

... More
code826 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. b) 2.5 sqmm

1400

42

58800

... More
code827 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. c) 4 sqmm

700

63

44100

... More
code828 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. d) 6 sqmm

100

92

9200

... More
code829 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. e) 10 sqmm

100

167

16700

... More
code830 - Supplying and Drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130-1984 and (virgin) PVC insulation and sheathed suitable for working voltage upto 1100volts as per IS-694:1990. a) 3Cx2.5Sqmm

50

113

5650

... More
code831 - Supplying and Drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130-1984 and (virgin) PVC insulation and sheathed suitable for working voltage upto 1100volts as per IS-694:1990. b) 3Cx4.0Sqmm

50

172

8600

... More
code832 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall a) 1-2 Way

10

138

1380

... More
code833 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall b) 3 Way

20

159

3180

... More
code834 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall c) 4 Way

5

177

885

... More
code835 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall d) 6 Way

30

220

6600

... More
code836 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall e) 8 Way

15

261

3915

... More
code837 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall f) 10-12 Way

5

319

1595

... More
code838 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall g) 16 Way

3

363

1089

... More
code839 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall h) 18 Way

2

405

810

... More
code840 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. a) 1 to 2 Module

10

137

1370

... More
code841 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. b) 3 Module

20

161

3220

... More
code842 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. c) 4 Module

5

175

875

... More
code843 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. d) 6 Module

30

234

7020

... More
code844 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. e) 8 Module

15

284

4260

... More
code845 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. f) 10-12 Module

5

344

1720

... More
code846 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. g) 16 Module

3

397

1191

... More
code847 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. h) 18 Module

2

457

914

... More
code848 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 a) 6 Amps one way

120

102

12240

... More
code849 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 b) 6 Amps Two way

6

166

996

... More
code850 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 c) 6Amps 3way socket.

30

171

5130

... More
code851 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 d) Stepped fan regulator

10

357

3570

... More
code852 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 e) 32A,DP,Switch

5

326

1630

... More
code853 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 f) 16Amps one way switch

25

180

4500

... More
code854 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 g) 6/16Amps universal socket

30

236

7080

... More
code855 - CONTROL SWITCH GEARS & ACCESSORIES Supplying push button operated, direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 400/440 volts 3 phase motor/single phase motor upto 5 HP.

2

1927

3854

... More
code856 - Supplying and fixing regular MCB distributionpanel confirming to IS 8828 , on wall/wood board/ flush mounting using required clamps, bolts, nuts etc.. With provision for fixing of suitable type capacity ELMCB / MCb's as an incomer for 3 phase double door with necessary bus bar completely wired to use on 440volts 3 phase 4 wired powder coated painting etc.. complete with provision for fixing of single/three phase suitable capacity ELMCB/MCb's as outgoings confirming to IS8828 . 8 way

1

12605

12605

... More
code857 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. a) 5-32Amps SP

40

415

16600

... More
code858 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. b) 5-32Amps DP

8

739

5912

... More
code859 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. c) 5-32Amps TPN

16

1717

27472

... More
code860 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. d) 40Amps TPN

2

3044

6088

... More
code861 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure a) Double Door 4 Way SP & N

1

1524

1524

... More
code862 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure c) Double Door 16 Way SP & N

1

2908

2908

... More
code863 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure d) Double Door 4 Way TP & N

1

4038

4038

... More
code864 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure d) Double Door 6 Way TP & N

1

4940

4940

... More
code865 - Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/ panel board. a) 32-40Amps 4 pole

1

5147

5147

... More
code866 - Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/ panel board. b) 63Amps 4 pole

2

5545

11090

... More
code867 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron ….and M.S. flat with bolts, washers etc… and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6

20

305

6100

... More
code868 - Supplying and fixing of metal Socket set of 2 pole and earth plugs and socket for incorporating SP and TP MCB (without MCB). The entire Plug and Socket shall be mounted in athermoplastic / powder coated metal box & wired completely. SP & N 20Amps

3

971

2913

... More
code869 - Supplying and fixing of metal Socket set of 2 pole and earth plugs and socket for incorporating SP and TP MCB (without MCB). The entire Plug and Socket shall be mounted in athermoplastic / powder coated metal box & wired completely. TP & N 30Amps

3

1700

5100

... More
code870 - EARTHING AND L.T. U.G. CABLES Supplying fixing and wiring earth electrode for grounding of DG Sets etc. using 40mm dia 2.9mm thick 2.5mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.

4

4256

17024

... More
code871 - Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. a) GI strip 25x3mm

100

82

8200

... More
code872 - Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. b) GI strip 25x6mm

30

128

3840

... More
code873 - Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. c) CU strip 25x3mm

10

570

5700

... More
code874 - Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. d) 600x600x3mm GI Plate

2

875

1750

... More
code875 - Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. e) 600x600x3mm CU Plate

2

7421

14842

... More
code876 - Supplying, Fixing & proper termination of vertical Air-termination using Gunmetal ball with finials of 5 spikes mounted on 2 mtrs long copper rod, mounted at the highest point of the building, with base plates, connection with horizontal conductor, necessary civil works, etc.

1

7500

7500

... More
code877 - Supply & fixing Test Link as per specification & drgs. and grouted to wall at 1200 mm. above ground level complete with all fixing accessories, clamps, screws etc, enclosed in M.S box.

1

3500

3500

... More
code878 - Supplying & Fixing Chemical earthing for grounding, conduits, IC cut outs & other equipments backfill compound which is non-corrosive, thermally conductive, potential to permissible limits, superior fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm. Using 10 ft copper bonded rod with backfill compound

2

8494

16988

... More
code879 - Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.. 8 SWG GI wire.

0.1

75040

7504

... More
code880 - Supplying of 1.1KV LT UG Aluminium cable XLPE insulated, PVC extruded inner sheathed, armourd UG LT cable as per the IS - 1554 (part-1) or IS-7098 part-1, Armoring strip thickness in average + 5% and resistivity 14 Ohms/Kms (Max) as per IS -3975. b) 4 core 10 sq.mm

0.05

118004

5900.2

... More
code881 - Supplying of 1.1KV LT UG Aluminium cable XLPE insulated, PVC extruded inner sheathed, armourd UG LT cable as per the IS - 1554 (part-1) or IS-7098 part-1, Armoring strip thickness in average + 5% and resistivity 14 Ohms/Kms (Max) as per IS -3975. c) 4 core 16 sq.mm

0.1

141842

14184.2

... More
code882 - Supplying of 1.1KV LT UG Aluminium cable XLPE insulated, PVC extruded inner sheathed, armourd UG LT cable as per the IS - 1554 (part-1) or IS-7098 part-1, Armoring strip thickness in average + 5% and resistivity 14 Ohms/Kms (Max) as per IS -3975. d) 3.5 core 70 sq.mm

0.1

317912

31791.2

... More
code883 - Labour charges for laying of 1.1 KV class UG cable in the existing trench GI pipe / stoneware pipe / on wall / on pole as required. On wall / Structure. a) 2.5 sqmm to 25 sqmm

0.15

20886

3132.9

... More
code884 - Labour charges for laying of 1.1 KV class UG cable in the existing trench GI pipe / stoneware pipe / on wall / on pole as required. On wall / Structure. b) 35 sqmm to 95 sqmm

0.1

31139

3113.9

... More
code885 - Supplying and fixing of heavy duty cable glands suitable for UG cable of1.1 KV class (metal only) a) 25mm

6

79

474

... More
code886 - Supplying and fixing of heavy duty cable glands suitable for UG cable of1.1 KV class (metal only) b) 32mm

4

95

380

... More
code887 - Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. a) 150x50mm

10

463

4630

... More
code888 - Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. b) 300x50mm

5

587

2935

... More
code889 - Aluminium End Terminal (Lug) a) 6 / 10 sq.mm

80

2

160

... More
code890 - Aluminium End Terminal (Lug) b) 16 sq.mm

10

2

20

... More
code891 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. a) 70 sq.mm Long barrel

10

89

890

... More
code892 - FANS Supplying exhaust fan of 1440RPM heavy duty with bracket blades complete for lighting duty suitable to operate on 230V 50Hz, AC supply.. 12" sweep (300mm)

10

2969

29690

... More
code893 - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.. 5 STAR 48" Sweep 5 Star (1200mm)

10

2677

26770

... More
code894 - Supplying wall mounting fan suitable to operate at single phase 230v AC supply. 400mm Sweep

5

3212

16060

... More
code895 - Fixing all types and all capacities fluorescent /false ceiling/spot light/CFL/LED fittings indoor on the wall / ceiling / rafters / girders using 23 / 0.00076 " twin twisted PVC insulated wires, required nos of round blocks and clamps. On wall / ceiling / Rafters / Girders

120

122

14640

... More
code896 - Using 2 Mtr long 19mm 18SWG enamelled braised conduit of two nos. rod pendent with ball socket with check nuts all nickel painted.

30

570

17100

... More
code897 - Extra length of GI pipe of class b 19mm dia for down rod.

30

197

5910

... More
code898 - Fixing a ceiling/wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing a 5 amps ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.

15

315

4725

... More
code899 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.

10

492

4920

... More
code900 - LED LUMINAIRS / LIGHT FIXTURES & ACCESSORIES Supplying and fixing of LED Bulk head of 10Wwith IP65 protection and IK08 impact resistance suitable for surfaceandwallmounting applications.

10

842

8420

... More
code901 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. a) Led light fitting 2' - 9 / 10 watts

5

551

2755

... More
code902 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. b) Led light fitting 4' - 20 / 22 watts

20

690

13800

... More
code903 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. c) Led light fitting 2 X 4' - 20 / 22 watts

20

1269

25380

... More
code904 - Supplying of Surface / recess mounting non integrated type LED down light …W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power / COB with CCT 6500 degree K, CRI 70%. efficacy 00 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level.

15

885

13275

... More
code905 - Supplying of recess mounting non integral type ........ LEDw luminairecomprising of pressure decast / extruded aluminium housing, withspring loaded false ceiling clamps, Power LEDs with CCT6500 degreeK, CRI70%. efficacy100lumen per W,120 degree beam spread, life25000 burning hours and Compliance to IS10322/IEC 60598, LM79&LM80. Thelampcompartment isenclosedwith anti glareopal diffuserwhichenhances the lighting level LEDsare drivenbyHFelectronicdriver integrated inaseparatecontrolgear assembly., withPF0.95, power loss should5%of lampWage., shortcircuit&opencircuitprotectiontobeintegrated inthecircuit, THDless than20%,LifeasperLM79. Theoperatinginputvoltage shouldbebetween130 to 275 V. BISApproved andTestedby NABL/CPRI accredited laboratory with2yearsWarranty against any manufacturing defect working under standard electrical condition. LED MODULAR DOWN LIGHT 2'x2' 36W

4

4553

18212

... More
code906 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. 70-80W FLOOD LED LIGHT

4

6768

27072

... More
code907 - Design, manufacture, supplying, fixing in position, testing and commissioning of following MV switchgear panels made up of 14/16G, suitable for 415 V, 3 phase, 4 wire, 50 Hz power distribution system. The incoming and outgoing feeders shall be accommodated in a modular multitier arrangement and shall be interlocked to avoid paralleling, adequate size cable alley, painting, earthing, numbering, danger plate etc. as required as per specifications and drawings. The panels should be with all items as per SLD and Specification. c) Supply, installation, testing & commissioning of MAIN SLAUGHTER HOUSE EB,DG AUTO CHANGEOVER PANEL- AS PER SLD suitable for 415 V, 3 ph, 4 wire, 50 Hz, power distribution system as per Single Line Diagram.

1

135000

135000

... More
code908 - Supplying, erecting, testing & commissioning of ONLINE UPS System suitable for operation on 230V, 50Hz, A/C supply with isolation transformer all accessories complete and Excluding batteries and wiring complete 3 KVA ONLINE UPS

1

38719

38719

... More
code909 - Supplying, installation, testing & commissioning of 12volts DC AH Batteries in poly propylene container for UPS Low maintenance Tubular/smf batteries. 12V, 75-80 AH Capacity. Acid battery.

4

10172

40688

... More
code910 - CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 1/3" progressive scan CMOS, 4.0 megapixel, IP based Colour camera, with 3-12mm verifocal lens, Up to 30 m IR range, Color: 0.01Lux, 1000TVL, Digital WDR (Wide Dynamic Range), 3D DNR (Digital Noise Reduction), PoE (Power over Ethernet/1 RJ45 10M/100M self-adaptive Ethernet port), IP67, Motion detection, Alarms (Video tampering, network disconnected, IP address conflicted), Protocols (TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, RTCP, NTP, UPnP, SMTP, IGMP, 802.1X, QoS, IPv6, Bonjour), Standard (ONVIF(PROFILE S,PROFILE G),PSIA,CGI,ISAPI), General Function (Anti-flicker, heartbeat, mirror, password protection, privacy mask, watermark), with base box, other necessary accessories. The cost shall includes end terminations.

6

11250

67500

... More
code911 - Supply, Installation, Testing & Commissioning of 8port 10/100/1000 Smart POE Switch with 4 SFP (192W)for camera connection including all necessary accessories.

1

7500

7500

... More
code912 - Supply, Installation, Testing & Commissioning of NVR (Networkable Video Recorder) - 8Channel NVR, Up to 8ch IP cameras input, Up to 5 Megapixels resolution recording HDMI and VGA output at up to 1920 1080P resolution,

1

20000

20000

... More
code913 - Supply, Installation, Testing & Commissioning of HDMI, Display Monitor 32" high resolution, Monitor with all mounting bracket accessories.

1

32000

32000

... More
code914 - Supply, laying and termination of CAT6 UTP, cable for IP BASED Camera power and video connection in existing Conduit / pipe.

200

34

6800

... More
code915 - NETWORKING AND COMMUNICATION : Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. a) TV/ Telephone socket

5

156

780

... More
code916 - NETWORKING AND COMMUNICATION : Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. b) RJ45/I.O. outlet

5

337

1685

... More
code917 - Supplying and drawing UTP-CAT 6 LAN cable.

150

38

5700

... More
code918 - Supplying and Drawing PVC flexible one pair telephone unarmoured tinned copper cable. a) 2 Pair

50

21

1050

... More
code919 - Supplying and Drawing PVC flexible one pair telephone unarmoured tinned copper cable. b) 5 Pair

100

46

4600

... More
code920 - Supplying and Drawing PVC flexible one pair telephone unarmoured tinned copper cable. c) 20 Pair

30

150

4500

... More
code921 - Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable. RG-6.

50

44

2200

... More
code922 - Supplying and fixing of switch mounting rack with power manager & cable manager. 6U with 450mm depth

1

6977

6977

... More
code923 - Supplying and fixing of power strip.

1

1457

1457

... More
code924 - Supplying and fixing of fan.

1

1209

1209

... More
code925 - Supplying fixing of Network Switches. 10 Port Gigabyte manageable

1

20200

20200

... More
code926 - Supplying & fixing of ….mtrs Cat6 Patch Cable - a) 1 mtr

5

224

1120

... More
code927 - b) 2 mtr

5

257

1285

... More
code928 - Supplying & fixing of Patch Panel for LAN cabling. 16 Port 10/100/1000 Patch Panel

1

7750

7750

... More
code929 - Supplying and Fixing of MDF Krone junction box with KRONE module / Telephone cable termination. 30 pair

1

568

568

... More
code930 - Supply and laying 6 Core Multimode OM3 outdoor Fiber Cable.

150

250

37500

... More
code931 - Supply and providing 12F, 1U, LC MM OM3, Loaded with Pigtails, Splice tray, adapter & splice protectors

1

12500

12500

... More
code932 - Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Manual Means a) In area of light jungle

3.63

1256

4561.5669

... More
code933 - Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.. In all kinds of soils upto 300 mm depth

72.7

106

7735.28

... More
code934 - Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m

448

271

121425.92

... More
code935 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

359

297

106953.28

... More
code936 - Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work

163

95

15517.6

... More
code937 - Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work.

93

530

49371.84

... More
code938 - Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.

316

132

41762.56

... More
code939 - Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates

45

6343

285465.6

... More
code940 - Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates

10.5

6963

73111.92

... More
code941 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates b) terrace Floor

4.5

7032

31647.015

... More
code942 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (Rate is inclusive of Shuttering) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

88

7096

624476.16

... More
code943 - Shuttering Work for Isolated Footing at 8 Percentage

60.01

567

34067.677

... More
code944 - Shuttering Work for Pedestals at 70 Percentage

8.37

4967

41577.3054

... More
code945 - Shuttering Work for Columns upto Plinth Beam at 70 Percentage

3.719

4967

18473.83498

... More
code946 - Shuttering Work for Plinth Beam at 50 Percentage

15.57

3548

55244.8512

... More
code947 - Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates

7

7257

50803.2

... More
code948 - Shuttering Work for Retaining Walls at10 Percentage

7

725

5080.32

... More
code949 - Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Rate is inclusive of Shuttering) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

78

7664

597804.48

... More
code950 - Shuttering Work for Columns at 70 Percentage- Ground Floor

12.462

5364

66857.50842

... More
code951 - Shuttering Work for Columns at 70 Percentage- First Floor

3.348

5418

18141.33888

... More
code952 - Shuttering Work for Lintel and Roof Beam at 60 Percentage-Ground Floor

13.32

4598

61251.8868

... More
code953 - Shuttering Work for Roof Slab at 50 Percentage- Ground Floor

50.2

3832

192370.416

... More
code954 - Shuttering Work for Chajja at 45 Percentage Ground Floor

1.06

3448

3655.8022

... More
code955 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a) Ground Floor

16.3

100191

1633126.992

... More
code956 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. b) terrace Floor

0.85

101193

86014.6875

... More
code957 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. a) Ground Floor

472

1467

692518.4

... More
code958 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. b) Terrace Floor

74

1481

109658.38

... More
code959 - Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. a) Ground floor

38

1236

46986.24

... More
code960 - Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. a) Ground Floor

504

204

103299.84

... More
code961 - Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI

12

7337

88045.44

... More
code962 - Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness

13

6405

83268.64

... More
code963 - Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.

1

110672

110672.8

... More
code964 - Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications.. ( excluding cost of fixtures )

5

7724

38623.2

... More
code965 - Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.. -do- 35 mm thick both side commercial

33

3720

122781.12

... More
code966 - Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 150mm

20

903

18076.8

... More
code967 - Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 35 mm thickness

7

4525

31681.44

... More
code968 - Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.

13

1137

14792.96

... More
code969 - Providing and fixing SS 304 Aldrop-250mm x 16mm (variation in size acceptable upto + / - 10%) suitable for door shutters including SS screws cost of materials, labour etc., complete as per specifications of vendor details. Make: Dorset / Godrej / Niell / Archis / Kadson / AKS / equivalent Model as per Specification.

13

1910

24830

... More
code970 - Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete

46

265

12210.24

... More
code971 - Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete a) Ground Floor

23

264

6079.36

... More
code972 - Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 25x85x5.5 mm (heavy type) a) Ground Floor

69

308

21252

... More
code973 - Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete

46

145

6697.6

... More
code974 - Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Aldrop 16mm dia, 200mm

8

336

2688

... More
code975 - Providing and fixing MS Holdfast of size 260mm x 25mm x 5mm thk for fixing door frame to walls including cost of materials, cutting masonry pockets for receiving MS Holdfast, one coat of shop primer , concrete filling of pockets, disposal of debris, keeping the area clean, curing, labour etc., complete as per specifications of vendor and as per architects details.

78

40

3120

... More
code976 - Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. C) Terrace Floor

325

924

300361.75

... More
code977 - Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates

24

7032

168784.08

... More
code978 - Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent..

14

2761

38666.88

... More
code979 - Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.

28

367

10286.08

... More
code980 - Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm

118

1316

155288

... More
code981 - Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge.

8

7465

59727.36

... More
code982 - Providing Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement :3 coarse sand), finished with a floating coat of neat cement. 18mm thick

5

539

2699.2

... More
code983 - Extra for making chequers of approved pattern on 1:2:4 cement concrete floors, steps, landing, pavements etc.

157

61

9671.2

... More
code984 - Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.

16

995

15930.88

... More
code985 - Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.

63

1622

102241.44

... More
code986 - Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.

10

4792

47924.8

... More
code987 - URINAL PARTITION - GRANITE Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.

1

3123

3123.68

... More
code988 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal wall plastering a) Ground Floor

796

312

248734.08

... More
code989 - Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Rough plastering a) Ground Floor

63

330

20815.2

... More
code990 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Plastering a) Ground Floor

314

415

130473.28

... More
code991 - Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Plastering b)Terrace floor

148

419

62111.16

... More
code992 - Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.

344

349

120207.36

... More
code993 - Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. Plaster mesh 100mm wide a) Ground Floor

524

38

19953.92

... More
code994 - Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (a) Ground Floor

1140

112

127680

... More
code995 - Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. a) Ground Floor

1140

182

208118.4

... More
code996 - Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. & Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. a) Ground Floor

314

159

49938.56

... More
code997 - Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. & Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. b) Terrace floor

148

160

23773.24

... More
code998 - Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. a) Ground Floor

48

128

6182.4

... More
code999 - Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.

30

154

4636.8

... More
code1000 - Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m

24

271

6504.96

... More
code1001 - Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m

19

290

5511.52

... More
code1002 - Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

19

297

5660.48

... More
code1003 - Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work

24

95

2284.8

... More
code1004 - Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates

2

6343

12687.36

... More
code1005 - Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (Rate is inclusive of Shuttering) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates

9.5

7096

67415.04

... More
code1006 - Shuttering Work for combined Footing at8 Percentage

2.95

212

627.996

... More
code1007 - Shuttering Work for retaining wall at10 Percentage

5.01

709

3555.2463

... More
code1008 - Shuttering Work for Slabat50 Percentage

1.47

3548

5215.7952

... More
code1009 - Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a) Ground Floor

0.942

100191

94380.71328

... More
code1010 - Food Graded Water Proofing Membrane Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification.

31

567

17603.04

... More
code1011 - Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates a) Ground Floor

0.5

6992

3496.08

... More
code1012 - Supplying and fixing of heavy duty SFRC manhole cover with frame 560MM size for underground tank.

1

5500

5500

... More
code1013 - Providing and fixing of PVC Rungs footrest in under ground tanks / manhole using M20 concrete bed blocks for masonry walls or during construction for RCC surfaces, including cost of materials, labour, curing etc., complete as per specifications.

6

300

1800

... More
code1014 - Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap a) Ground Floor

4

2626

10505.6

... More
code1015 - Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover,and cistern fittings, nuts, bolts and gasket etc complete. a) Ground Floor

2

12570

25141.76

... More
code1016 - Providing and fixing CP. Health faucet with flexible hose,CP Bibcock with 2 in 1 connectvity, wall flange, supporting hook with screws, fixing materials and sealant to all sides of wall flange complete. Make :

2

3000

6000

... More
code1017 - Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.

7

812

5684

... More
code1018 - Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931

10

711

7112

... More
code1019 - Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.

4

1366

5465.6

... More
code1020 - Supplying , shifting to the place of installation and fixing testing and commissioning of stainless steel soap dish 150 x 150mm including cutting and setting in walls with cement joints and making good the wall. Make : JAQUAR Model No- ACN -1131N

4

834

3336

... More
code1021 - Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern

1

9679

9679.04

... More
code1022 - Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm

2

5566

11132.8

... More
code1023 - Supplying & fixing of CP sink mixer with swivel spout with wall flange etc complete. Make : Jaquar Model No- F-5347D

2

3050

6100

... More
code1024 - Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm Dia

6

103

618.18

... More
code1025 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 75mm dia., 6 kg/sqcm & class 3

32

246

7884.8

... More
code1026 - Supply and delivery at site special moulded variety 75 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

7

75

525.21

... More
code1027 - Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

5

215

1075.2

... More
code1028 - Supply and delivery at site special moulded variety 75 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

5

131

655.2

... More
code1029 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3

20

460

9206.4

... More
code1030 - Supply and delivery at site special moulded variety 110 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

3

191

574.56

... More
code1031 - Supply and delivery at site special moulded variety 110 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

3

338

1014.72

... More
code1032 - Supply and delivery at site special moulded variety 110 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

3

281

843.36

... More
code1033 - Providing & fixing, testing and commissioning u PVC multi inlet floor trap 75mm dia conforming to IS 13592 with required P C C support placed to required level as per site condition complete..

12

552

6624

... More
code1034 - Supplying and fixing PVC P' trap 110mm dia, of self cleansing design with or without vent arm complete including cutting and making good the walls and floors.

1

732

732

... More
code1035 - Providing & Fixing in position heavy duty C P grating 125mm dia, with frame of below mentioned sizes including jointing and fixing material complete.

13

282

3666

... More
code1036 - Providing and grouting sleeves made in beam/ slab to draw waste and soil lines at all floor level of the below mentioned sizes , including condcting water ponding test to ensure zero leakage with all leads and lifts complete Size : 150 mm dia

6

720

4320

... More
code1037 - Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete,As per direction of engineer in charge Concealed work including cutting chases and good the walls etc. 20 mm dia pipe nominal OD pipes

50

424

21224

... More
code1038 - Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete,As per direction of engineer in charge Concealed work including cutting chases and good the walls etc. 25 mm dia pipe nominal OD pipes

50

534

26712

... More
code1039 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :20 mm nominal bore.

6

351

2110.08

... More
code1040 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25 mm nominal bore

1

614

614.88

... More
code1041 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm dia pipe nominal OD pipes

70

243

17012.8

... More
code1042 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia pipe nominal OD pipes

25

331

8288

... More
code1043 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm dia pipe nominal OD pipes

50

416

20832

... More
code1044 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 40 mm dia pipe nominal OD pipes

54

534

28848.96

... More
code1045 - Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia pipe nominal OD pipes

20

807

16150.4

... More
code1046 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :20 mm nominal bore.

6

351

2110.08

... More
code1047 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25 mm nominal bore.

4

614

2459.52

... More
code1048 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal bore

4

669

2679.04

... More
code1049 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :40 mm nominal bore

2

786

1572.48

... More
code1050 - Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :50 mm nominal bore

2

957

1915.2

... More
code1051 - Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

2000

10

20160

... More
code1052 - Supplying & fixing suction Y'/ pot stainer with MS flange of suitable length fabricated from 16 gauge brass sheet with 3mm slots. 50 mm dia

2

4344

8688

... More
code1053 - Supplying , fixing, testing and commissioning of PVC welded rain water head / khurras dome type grating with puddle flange to fix head in RCC slab specially fabricated from minimum 4mm thick PVC sheet, including removable heavy duty PVC grating of 50 x 3 mm thick PVC flats (Round or Square) as per approved design The quoted rate shall include for necessary grouting the khurras base with approved sealant complete all as shown in the drawing and as specified. 150 x 150mm PVC Grating

5

830

4150

... More
code1054 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 75mm dia., 6 kg/sqcm & class 3

89

246

21929.6

... More
code1055 - Supply and delivery at site special moulded variety 75 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

10

75

750.3

... More
code1056 - Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

10

215

2150.4

... More
code1057 - Supply and delivery at site special moulded variety 75 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

10

131

1310.4

... More
code1058 - Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 a) Ground Floor

88

460

40508.16

... More
code1059 - Supply and delivery at site special moulded variety 110 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

5

191

957.6

... More
code1060 - Supply and delivery at site special moulded variety 110 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

5

338

1691.2

... More
code1061 - Supply and delivery at site special moulded variety 110 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

5

281

1405.6

... More
code1062 - Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 160mm dia., 6 kg/sqcm & class 3

30

692

20764.8

... More
code1063 - Supply and delivery at site special moulded variety 160 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments

4

375

1500.8

... More
code1064 - Supply and delivery at site special moulded variety 160 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

4

527

2110.08

... More
code1065 - Supply and delivery at site special moulded variety 160 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments

4

521

2087.68

... More
code1066 - Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete

8

387

3100.16

... More
code1067 - Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover

4

6108

24433.92

... More
code1068 - Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m

24

542

13009.92

... More
code1069 - DOMESTIC WATER TRANSFAR PUMP Supplying, installing, testing and commissioning of submersible / Mono blockelectrical driven pump 1set . (1 working & standby) domestic water pumps for pumping domestic water from U.G. sump to over head water tank, with all necessary arrangements to operate on 3HP 50 HZ, 440V AC supply fitted on a common base frame accessories to lift the pump during maintenance , necessary power connections, the supplier shall include the control panel and wiring from TPN switch to control panel and wiring upto pumps, the control panel comprising of O/L relays, single phase preventor,separate overload trip and relayset, ON/OFF/TRIP indicating lamps,start/stop push buttons, With liquid level controlers, etc., complete as complete. Duty of the Pump 4 cum per hour at 20 TO 25 m head Make : Kirloskar/ suguna/texmo/CRI two set industrial type electronic automatic liquid level controllers, with stainless steel probes / sensors.

1

24000

24000

... More
code1070 - Providing and fixing gun metal non- return valve of approved quality (screwed end) 32 mm nominal bore Vertical

1

1036

1036

... More
code1071 - Providing and fixing gun metal non- return valve of approved quality (screwed end) 40 mm nominal bore Vertical

1

1372

1372

... More
code1072 - Construction of brick masonry catch basin chamber chambers of internal clear dimension as mentioned below by using first class table moulded modular bricks 230 mm thick wall in cement mortor joints in 1:4, over CC 1:4:8 bed 150 mm thick including Supplying precast RCC perforated top slab in 1:2:4 Mix (1 cement: 2 coarse coarse sand: 8 graded stone aggregate), with angle iron frame, inside plastering15mm thick with CM 1:3 (1 cement::3 fine sand) finished very smooth with floating coat of neat cement & making benching and channelling in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 gradedstone aggregate) neatly finished complete as per standard design and as per drawing and specifications.Inside size of 600 x 600mm & depth not exceeding 600 x 600mm including Supplying 450 x 450mm RCC cover with MS L angle frame.

1

6920

6920.4

... More
code1073 - Construction of percolation well / rain water harvest pit of 2 m dia and 3m deep with precast RCC rings, coveringthe top with RCC slab including supply and fixing 600 x 600 RCC MH cover CI / MS rungs etc. The quoted rate shall include earth work excavation, back filling, removing excess earth and making good the floor. The percolation well harvest pit shall be constructed as per the detail drawings and specification shall consists of: Allernate layers of brick bats, activated charcoal, gravel, pebbles and toped with fine sand for good infiltration. 3 Nos. bore holes of 160 mm dia from the bottom of percolation pit for a depth of 6m, drilled by using auger manually.Bore hole to be filled with medium sized pebbles to provide mechanical strength to the holes and enhance infiltration. Rate quoted shall be inclusive of earth work excavation, back filling, removing of excess earth as per the instructions of engineer - in charge.

1

27883

27883

... More
code1074 - Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. 32 mm dia

2

696

1392

... More
code1075 - Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. 40 mm dia

2

828

1656

... More
code1076 - Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. 50 mm dia

2

1044

2088

... More
code1077 - Supply and fixing 600mm long puddle flange consisting of 6mm thick welded MS plate, flanges of sutible size property fixed in walls of water tanks as per specifications and approved drawings of following diameters. 65 mm dia

2

1398

2796

... More
code1078 - LT ELECTRICAL WORKS PVC CONDUITS & ITS ACCESSORIES Open conduit System Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. a) 19/20 mm dia 2mm thick

130

69

8970

... More
code1079 - Open conduit System Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. b) 25mm dia 2mm thick

150

81

12150

... More
code1080 - Open conduit System Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. c) 32mm dia 2.5mm thick

75

106

7950

... More
code1081 - Concealed conduit System Supplying heavy gauge PVC conduit pipe ……mm dia ......mm thick confirming to IS 2509 with suitable size bends, metals/PVC junction boxes, adhesives paste etc., and running before concreting the slab . The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. a) 19/20 mm dia 2mm thick

400

66

26400

... More
code1082 - Concealed conduit System Supplying heavy gauge PVC conduit pipe ……mm dia ......mm thick confirming to IS 2509 with suitable size bends, metals/PVC junction boxes, adhesives paste etc., and running before concreting the slab . The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. b) 25mm dia 2mm thick

675

78

52650

... More
code1083 - Concealed conduit System Supplying heavy gauge PVC conduit pipe ……mm dia ......mm thick confirming to IS 2509 with suitable size bends, metals/PVC junction boxes, adhesives paste etc., and running before concreting the slab . The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. c) 32mm dia 2.5mm thick

70

103

7210

... More
code1084 - Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc. By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary a) 19/20 mm dia 2mm thick

25

68

1700

... More
code1085 - Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc. By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary b) 25mm dia 2mm thick

50

79

3950

... More
code1086 - Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc. By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary c) 32mm dia 2.5mm thick

30

99

2970

... More
code1087 - Supplying and fixing PVC/metal conduit deep junction box. a) 19/20mm deep junction box

30

49

1470

... More
code1088 - Supplying and fixing PVC/metal conduit deep junction box. b) 25mm deep junction box

45

56

2520

... More
code1089 - Supplying and fixing PVC/metal conduit deep junction box. c) 32mm deep junction box

10

61

610

... More
code1090 - Extra for Groove cutting in brick wall/cc floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing the wall upto wall surface complete. a) upto 50mm conduit in CC Floor

70

69

4830

... More
code1091 - Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm..using NF screws and on either end of the pipe terminated completely. a) 25 mm

75.9

22

1669.8

... More
code1092 - Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm..using NF screws and on either end of the pipe terminated completely. b) 32 mm

10

29

290

... More
code1093 - Supplying and fixing Metal fan box with round hook.

20

117

2340

... More
code1094 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. a) Short point up to 3Mtr from tapping point to out let via switch box

15

269

4035

... More
code1095 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. b) Medium point above 3Mtr up to 6Mtrs from tapping point to out let via switch box

18

379

6822

... More
code1096 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box

25

555

13875

... More
code1097 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. d) Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switch box

18

677

12186

... More
code1098 - Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. e) Three outlet in a row, above 6Mtr up to 10Mtr from tapping point to out let via switches box

5

989

4945

... More
code1099 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. a) 1.5 sqmm

250

26

6500

... More
code1100 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. b) 2.5 sqmm

850

42

35700

... More
code1101 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. c) 4 sqmm

900

63

56700

... More
code1102 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. d) 6 sqmm

100

92

9200

... More
code1103 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. e) 10 sqmm

75

167

12525

... More
code1104 - Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments. f) 16 sqmm

20

318

6360

... More
code1105 - Supplying and Drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130-1984 and (virgin) PVC insulation and sheathed suitable for working voltage upto 1100volts as per IS-694:1990. a) 3Cx2.5Sqmm

50

113

5650

... More
code1106 - Supplying and Drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130-1984 and (virgin) PVC insulation and sheathed suitable for working voltage upto 1100volts as per IS-694:1990. b) 3Cx4.0Sqmm

50

172

8600

... More
code1107 - SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall a) 1-2 Way

12

138

1656

... More
code1108 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall b) 3 Way

28

159

4452

... More
code1109 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall c) 4 Way

6

177

1062

... More
code1110 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall d) 6 Way

12

220

2640

... More
code1111 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall e) 8 Way

17

261

4437

... More
code1112 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall f) 10-12 Way

4

319

1276

... More
code1113 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall g) 16 Way

2

363

726

... More
code1114 - Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall h) 18 Way

1

405

405

... More
code1115 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. a) 1 to 2 Module

12

137

1644

... More
code1116 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. b) 3 Module

28

161

4508

... More
code1117 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. c) 4 Module

6

175

1050

... More
code1118 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. d) 6 Module

12

234

2808

... More
code1119 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. e) 8 Module

17

284

4828

... More
code1120 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. f) 10-12 Module

4

344

1376

... More
code1121 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. g) 16 Module

2

397

794

... More
code1122 - Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/ metal PVC box. h) 18 Module

1

457

457

... More
code1123 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 a) 6 Amps one way

100

102

10200

... More
code1124 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 b) 6 Amps Two way

2

166

332

... More
code1125 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 c) 6Amps 3way socket.

25

171

4275

... More
code1126 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 d) Stepped fan regulator

20

357

7140

... More
code1127 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 e) 32A,DP,Switch

7

326

2282

... More
code1128 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 f) 16Amps one way switch

15

180

2700

... More
code1129 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293 g) 6/16Amps universal socket

22

236

5192

... More
code1130 - CONTROL SWITCH GEARS & ACCESSORIES Supplying push button operated, direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 400/440 volts 3 phase motor/single phase motor upto 5 HP.

1

1927

1927

... More
code1131 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. a) 5-32Amps SP

45

415

18675

... More
code1132 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. b) 5-32Amps DP

8

739

5912

... More
code1133 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. c) 5-32Amps TPN

6

1717

10302

... More
code1134 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. d) 40Amps TPN

2

3044

6088

... More
code1135 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. e) 63Amps TPN

1

3088

3088

... More
code1136 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure a) Double Door 4 Way SP & N

1

1524

1524

... More
code1137 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure b) Double Door 16 Way SP & N

1

2908

2908

... More
code1138 - Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc., with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS Enclosure c) Double Door 4 Way TP & N

2

4038

8076

... More
code1139 - Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/ panel board. a) 32-40Amps 4 pole

2

5147

10294

... More
code1140 - Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/ panel board. b) 63Amps 4 pole

1

5545

5545

... More
code1141 - Supplying and fixing angle iron frame work fabricated out of M.S. angle iron ….and M.S. flat with bolts, washers etc… and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6

10

305

3050

... More
code1142 - Supplying and fixing of metal Socket set of 2 pole and earth plugs and socket for incorporating SP and TP MCB (without MCB). The entire Plug and Socket shall be mounted in athermoplastic / powder coated metal box & wired completely. SP & N 20Amps

4

971

3884

... More
code1143 - Supplying and fixing of metal Socket set of 2 pole and earth plugs and socket for incorporating SP and TP MCB (without MCB). The entire Plug and Socket shall be mounted in athermoplastic / powder coated metal box & wired completely. TP & N 30Amps

4

1700

6800

... More
code1144 - EARTHING AND L.T. U.G. CABLES Supplying fixing and wiring earth electrode for grounding of DG Sets etc. using 40mm dia 2.9mm thick 2.5mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.

2

4256

8512

... More
code1145 - Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. a) GI strip 25x3mm

30

82

2460

... More
code1146 - Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. c) CU strip 25x3mm

2

570

1140

... More
code1147 - Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. d) 600x600x3mm GI Plate

2

875

1750

... More
code1148 - Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.. 8 SWG GI wire.

0.1

75040

7504

... More
code1149 - Supplying of 1.1KV LT UG Aluminium cable XLPE insulated, PVC extruded inner sheathed, armourd UG LT cable as per the IS - 1554 (part-1) or IS-7098 part-1, Armoring strip thickness in average + 5% and resistivity 14 Ohms/Kms (Max) as per IS -3975. b) 4 core 10 sq.mm

0.075

118004

8850.3

... More
code1150 - Supplying of 1.1KV LT UG Aluminium cable XLPE insulated, PVC extruded inner sheathed, armourd UG LT cable as per the IS - 1554 (part-1) or IS-7098 part-1, Armoring strip thickness in average + 5% and resistivity 14 Ohms/Kms (Max) as per IS -3975. c) 4 core 16 sq.mm

0.05

141842

7092.1

... More
code1151 - Supplying of 1.1KV LT UG Aluminium cable XLPE insulated, PVC extruded inner sheathed, armourd UG LT cable as per the IS - 1554 (part-1) or IS-7098 part-1, Armoring strip thickness in average + 5% and resistivity 14 Ohms/Kms (Max) as per IS -3975. d) 3.5 core 50 sq.mm

0.1

178793

17879.3

... More
code1152 - Labour charges for laying of 1.1 KV class UG cable in the existing trench GI pipe / stoneware pipe / on wall / on pole as required. On wall / Structure. a) 2.5 sqmm to 25 sqmm

0.13

20886

2715.18

... More
code1153 - Labour charges for laying of 1.1 KV class UG cable in the existing trench GI pipe / stoneware pipe / on wall / on pole as required. On wall / Structure. b) 35 sqmm to 95 sqmm

0.1

31139

3113.9

... More
code1154 - Supplying and fixing of heavy duty cable glands suitable for UG cable of1.1 KV class (metal only) a) 25mm

4

79

316

... More
code1155 - Supplying and fixing of heavy duty cable glands suitable for UG cable of1.1 KV class (metal only) b) 45mm

2

197

394

... More
code1156 - Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. a) 150x50mm

5

463

2315

... More
code1157 - b) 300x50mm

5

587

2935

... More
code1158 - Aluminium End Terminal (Lug) a) 2.5 / 10 sq.mm

200

2

400

... More
code1159 - Aluminium End Terminal (Lug) b) 16 sq.mm

10

2

20

... More
code1160 - Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. a) 50 sq.mm Long barrel

10

58

580

... More
code1161 - FANS Supplying exhaust fan of 1440RPM heavy duty with bracket blades complete for lighting duty suitable to operate on 230V 50Hz, AC supply.. 12" sweep (300mm)

12

2969

35628

... More
code1162 - Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W - 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.. 5 STAR 48" Sweep 5 Star (1200mm)

20

2677

53540

... More
code1163 - Supplying wall mounting fan suitable to operate at single phase 230v AC supply. 400mm Sweep

2

3212

6424

... More
code1164 - Fixing all types and all capacities fluorescent /false ceiling/spot light/CFL/LED fittings indoor on the wall / ceiling / rafters / girders using 23 / 0.00076 " twin twisted PVC insulated wires, required nos of round blocks and clamps. On wall / ceiling / Rafters / Girders

75

122

9150

... More
code1165 - Fixing a ceiling/wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing a 5 amps ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.

20

315

6300

... More
code1166 - Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.

12

492

5904

... More
code1167 - LED LUMINAIRS / LIGHT FIXTURES & ACCESSORIES Supplying and fixing of LED Bulk head of 10Wwith IP65 protection and IK08 impact resistance suitable for surfaceandwallmounting applications.

10

842

8420

... More
code1168 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. a) Led light fitting 2' - 9 / 10 watts

5

551

2755

... More
code1169 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. b) Led light fitting 4' - 20 / 22 watts

12

690

8280

... More
code1170 - Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. c) Led light fitting 2 X 4' - 20 / 22 watts

25

1269

31725

... More
code1171 - Supplying of Surface / recess mounting non integrated type LED down light …W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power / COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit THD Less then 20%, Life as per LM 79, The operating input voltage should be between 130 to 275 volts, BIS Approved and tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 10-12W

10

885

8850

... More
code1172 - Supplying of Surface / recess mounting non integrated type LED down light …W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power / COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit THD Less then 20%, Life as per LM 79, The operating input voltage should be between 130 to 275 volts, BIS Approved and tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 15-18W

16

1324

21184

... More
code1173 - Supply of 2X2 LED recessed / surface luminaire with watts system wattage. Housing shall be with pressure die cast aluminum alloy with corrosion proof resistant polyester powder coated. Driver operates with voltage range from 100V to 270V 50/60Hz with short circuit, overloaded, & miswiring. . Lumen maintenance of 70% @ 50000 Hrs. injection moulded polycarbonate diffuser for better mechanical stability, light transmission & avoid pot hole effect. Junction temperature shall be 70 deg Celsius. Driver is on constant current driver driver @ 0.06A with PF 0.92 with line voltage @220-240V @ 50/60Hz, driver efficiency 85% & THD15%. LEd efficiency 130ml/w at 1w and fixture efficiency 75ml/w with CRI 75 with injection moulded polycarbonate lens. 5 years warranty against any manufacturing defect working under standard electrical condition

2

4553

9106

... More
code1174 - Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB.

4

6768

27072

... More
code1175 - Fabricating supplying and mounting MS box made out … SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint and Powder coating. etc., complete. 14SWG

15000

-

7500

... More
code1176 - Supply and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of overload and short circuit with thermal magnetic/micro processor releases and earth fault as per IS-13947. (Icu=Ics). In 4P MCCB, all poles should have protection for short -circuit/over load. For Microprocessor MCCBS Facility for segregating priority and Non -Priority load must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. THREE POLE 100Amps 25kA

1

6086

6086

... More
code1177 - Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220V AC, 50Hz 12/24V DC.

3

515

1545

... More
code1178 - Supplying, fixing and wiring 3 phase Digit Digital Ammeter/Voltmeter

1

1425

1425

... More
code1179 - Supplying, fixing and wiring 50/5A to 400/5A 5VA burden current transformer class 0.5 accuracy with Tape wound

1

562

562

... More
code1180 - Supplying of multi function Meter digital three line back light LCD type display of voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required wit communication Port and class 0.5s accuracy.

1

9315

9315

... More
code1181 - Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50Hz AC with latest microcontroller based, digital read out of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail / flush mounting panel board.

1

9255

9255

... More
code1182 - Supplying …….amps rated 3 phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M S flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 5x30x6mm Aluminum Strips.

3

2465

7395

... More
code1183 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60899 6-32 Amps SP

4

415

1660

... More
code1184 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60899 6-32 Amps TPN

8

1717

13736

... More
code1185 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60899 40 Amps TPN

2

3044

6088

... More
code1186 - Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60899 50-63 Amps TPN

2

3088

6176

... More
code1187 - Supplying, erecting, testing & commissioning of ONLINE UPS System suitable for operation on 230V, 50Hz, A/C supply with isolation transformer all accessories complete and Excluding batteries and wiring complete 3 KVA ONLINE UPS

1

38719

38719

... More
code1188 - Supplying, installation, testing & commissioning of 12volts DC AH Batteries in poly propylene container for UPS Low maintenance Tubular/smf batteries. 12V, 75-80 AH Capacity. Acid battery.

3

10172

30516

... More
code1189 - CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 1/3" progressive scan CMOS, 4.0 megapixel, IP based Colour camera, with 3-12mm verifocal lens, Up to 30 m IR range, Color: 0.01Lux, 1000TVL, Digital WDR (Wide Dynamic Range), 3D DNR (Digital Noise Reduction), PoE (Power over Ethernet/1 RJ45 10M/100M self-adaptive Ethernet port), IP67, Motion detection, Alarms (Video tampering, network disconnected, IP address conflicted), Protocols (TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, RTCP, NTP, UPnP, SMTP, IGMP, 802.1X, QoS, IPv6, Bonjour), Standard (ONVIF(PROFILE S,PROFILE G),PSIA,CGI,ISAPI), General Function (Anti-flicker, heartbeat, mirror, password protection, privacy mask, watermark), with base box, other necessary accessories. The cost shall includes end terminations.

6

11250

67500

... More
code1190 - Supply, Installation, Testing & Commissioning of 8port 10/100/1000 Smart POE Switch with 4 SFP (192W)for camera connection including all necessary accessories.

1

7500

7500

... More
code1191 - Supply Installation Testing Commissioning of NVR (Networkable Video Recorder) 8Channel NVR, Up to 8ch IP cameras input, Up to 5 Megapixels resolution recording

1

20000

20000

... More
code1192 - Supply, Installation, Testing & Commissioning of HDMI, Display Monitor 32" high resolution, Monitor with all mounting bracket accessories.

1

32000

32000

... More
code1193 - Supply, laying and termination of CAT6 UTP, cable for IP BASED Camera power and video connection in existing Conduit / pipe.

150

34

5100

... More
code1194 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. a) TV/ Telephone socket

5

156

780

... More
code1195 - Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc. on existing modular switch plate as per IS 3854 and IS 1293. b) RJ45/I.O. outlet

8

337

2696

... More
code1196 - Supplying and drawing UTP-CAT 6 LAN cable.

200

38

7600

... More
code1197 - Supplying and Drawing PVC flexible one pair telephone unarmoured tinned copper cable. a) 2 Pair

100

21

2100

... More
code1198 - Supplying and Drawing PVC flexible one pair telephone unarmoured tinned copper cable. b) 5 Pair

100

46

4600

... More
code1199 - Supplying and Drawing PVC flexible one pair telephone unarmoured tinned copper cable. c) 20 Pair

10

150

1500

... More
code1200 - Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable. RG-6.

50

44

2200

... More
code1201 - Supplying and fixing of switch mounting rack with power manager & cable manager. 9U with 450mm depth

1

8476

8476

... More
code1202 - Supplying and fixing of power strip.

1

1457

1457

... More
code1203 - Supplying and fixing of fan.

1

1209

1209

... More
code1204 - Supplying fixing of Network Switches. 10 Port Gigabyte manageable

1

20200

20200

... More
code1205 - Supplying & fixing of ….mtrs Cat6 Patch Cable - a) 1 mtr

8

224

1792

... More
code1206 - b) 2 mtr

8

257

2056

... More
code1207 - Supplying & fixing of Patch Panel for LAN cabling. 16 Port 10/100/1000 Patch Panel

1

7750

7750

... More
code1208 - Supplying and Fixing of MDF Krone junction box with KRONE module / Telephone cable termination. 30 pair

1

568

568

... More
code1209 - Supply and laying 6 Core Multimode OM3 outdoor Fiber Cable.

50

250

12500

... More
code1210 - Supply and providing 12F, 1U, LC MM OM3, Loaded with Pigtails, Splice tray, adapter & splice protectors

1

12500

12500



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.