Karnataka Urban Water Supply And Drainage Board Tender

Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.

Karnataka Urban Water Supply And Drainage Board - KUWSDB Tender

Works
Civil And Construction
Water Storage And Supply
Opening Date18 Oct 2024
Closing Date4 Nov 2024
Tender Amount₹ 17,99,646 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
code04 - Wiring: Identification, ferruling, crimping and termination of wires in Breaker limbs, marshalling box & wiring up to control panel/ relay panels, extension of earth mat, etc., Complete as directed by the Engineer-in-charge.

1

8487

8487

... More
code05 - Testing & Commissioning: Test for insulation level/IR value, gas leakage, testing for travel time (C, O & CO & OC), trip and close timings. Local trip close test, remote trip and close test, tripping through relays, operation of interlocks, contact resistance test, etc., Complete as directed by the Engineer-in-charge. DCRM for 220 kV and above class.

1

33813

33813

... More
code06 - Dismantling of existing Breaker, etc., Complete as directed by the Engineer-in-charge.

1

7787

7787

... More
code07 - Supply, installation & commissioning of new 6.6KV, 1000HP Neutral Soft Starter Panel comprise of following conforming to detailed specifications below: Brand new any Board approved make fully automatic push button operated 3phase soft starter suitable for 1000HP 6.6 KV 3 Ph. 50 Hz supply and suitable for connection to phase segregated neutral terminal box on neutral side of HT motor Soft starter panel should also include. The reactor provided shall be for 3 phases. 400 A Vacuum contactors of any Board approved make- 1 Nos Surge suppressors. CT's- one set, Timers, P.B.s & Indicating lamps of any Board approved make. 2 Nos. Aux. Relay VAA-33 or equivalent for alarm and trip system of motor winding, motor bearing temperature detection. 1 No. of Multi function meter for mearuement of current, voltage, P.F, KWH, KVAR etc., of any approved make or equivalent. Control supply should be 110 V D.C/230 V AC Space heaters with switch plug and socket, panel lamp working on 230 V A.C Busbars should be of aluminium of size 40mm x 10mm min, etc., Complete as directed by the Engineer-in-charge. NOTE: 1. The Soft starter shall be rated equivalent to the motor rated power and shall be capable of operating satisfactorily with the motor under the various loading and starting conditions of the motor over the entire range of operation. 2. The Soft starter shall reduce, the starting current of the motor atleast to 80% of the directed line starting current of the motor. The soft starter shall have facility to further reduce the current upto 50% of the direct on line starting current if the motor and the pump torque speed curved permit. 3. The soft starter shall work on the principle of unsaturated core in the working zone and shall not lead to generation of Harmonics. 4. Soft starter shall be so rated as to allow two consecutive starts from cold or one hot start per hour. 5. Soft starter shall be designed for supply voltage of + OR - 10% and Frequency Variation of + OR - 3%. 6. The winding of the soft starter shall be with insulation class 'F' & maximum temp of winding shall be limited to that of Class 'B'. 7. The soft starter shall be housed in a sheet steel enclosure of thickness not less than 14 guage and painted with corrosion resistive paint such as epoxy or Polyurethene. The degree of protection shall be IP 41. 8. The starter shall not contain any active electronic components.9. the starter shall have a built in facility for run bypass so that the incoming voltage to the motor is equal to the supply voltage. 10. The the unit should be Air cooled. 11. The soft starter shall be dust and vermine proof and suitable for indoor mounting. 12. The Soft starter shall not remain in circuit , if the control supply to the circuit fails and it shall trip the tripping device of the motor

1

785000

785000

... More
code08 - Repairs and replacement of following materials in the existing 110V DC 200Ah Battery Charger panel: for Meters on DC side - Voltmeter at Charger output and load side ammeter for battery charger current and DC load current. indicating lamps for: a) AC mains fail, b) Float charger fail, c) Float / cum booster charger fail, d) Batter under voltage, e) Batter over voltage, f) Annunciation circuit, and Control Card and Control Transformer checking and other essential works to be carried out for smooth functioning, etc., Complete as directed by the Engineer-in-charge.

1

150000

150000

... More
code09 - AC/DC Control Cable re rooting and reconnection checking for 6.6 KV main panel and neutral soft starter panels & LT panels. Old control cabels 3 core & 4 core cables all re-rooting for main panels 6.6 KV VCB, 3 phase, 50Hz, 3 nos. of main incommers & 3 Nos. of outgoing VCBs for motor controler & 2 Nos. of Bus couplers VCBs & neutral soft starter shall be checked & cables re-rooted including labour charges & transportation and other essential works to be carried out for smooth functioning, including replacement of damaged control cable and termination necessary for sucessful operation of panels, etc., Complete as directed by the Engineer-in-charge.

1

100000

100000



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.