Karnataka, also known as Karunadu, is a state in the southwestern region of India. Karnataka was formed originally as Mysore State on 1st November 1956 and currently is the biggest state in south India. Its capital and largest city is Bengaluru. It covers an area of 191,791 km2 (74,051 sq mi) and is the sixth largest state by area comprising 31 districts. Karnataka is also a state of multiple languages; Kannada being the official and most widely spoken language in Karnataka. Other languages spoken in the state include Tamil, Telugu, Malayalam, Kodava, Konkani and much more.Karnataka tenders are issued by the government of Karnataka, public & private sector organisations. The state government issues majority of the Karnataka tenders, which are for goods and services including construction, road and bridge construction, IT services, engineering services, medical services, educational services amongst many others. Bidassist is one of the largest eprocurement portals, which offers all government tenders from across the world in one place. Bidassist offers information on all Karnataka tenders and other state and authority tenders in no time. Bidassist is a platform where users can look for various Karnataka tenders as well as other tenders.
Costs
EMD
₹ 1,14,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
KUWSDB/2021-22/WS/WORK_INDENT3118Bid Award Id
ViewTender No
KUWSDB/2021-22/WS/WORK_INDENT3118Tender Authority
Karnataka Urban Water Supply And Drainage Board ViewPurchaser Address
-Website
http://eproc.karnataka.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Approximate 200x 150mm or suitable size flanged concentric reducer
2
-
8677.8
... More
For delivery side : Minimum 200 mm dia or suitable size flanged pipes
20
-
107360
... More
Approximate 200x 125mm or suitable size flanged concentric reducer
2
-
6000
... More
Minimum 80mm dia 'B' class GI pipe of TATA or any other approved make for connecting outlet of pressure releif valve to sump
50
-
29050
... More
Manifold : Supply & delivery at site brand new best indepenous make M.S. pipe manifold of 10mm wall thickness and 350mm dia.
20
-
163280
... More
Minimum 350x350x80 mm dia or suitable size flanged Tee with radial branch for installing pressure relief valve.
1
-
19167
... More
Minimum 350x350x200 mm dia or suitable size flanged Tee with radial branch.
2
-
41522
... More
Minimum 350 mm dia MS blank flange of thickness as per IS.
1
-
2156
... More
Dismantling joint; Providing, installing at site of works and testing Dismantling joints in pump delivery pipe line complete, suitable for following specifications and confirming to detailed specifications. a) Diameter 200 mm b) Working pressure 16 kg/cm2 PN(16)
2
-
29416
... More
Sluice valve Supply, & delivery of resilient sealed soft sealing sluice valves with body, bonnet of ductile iron of Grade GGG50, wedge fully rubber lined with EPDM and seals of NBR and the valves should be of Vacuum tight and 100% leak proff with face dimensions as per BS 5163-89/ IS 14846-2000/ DIN3202 F4\f5 . The stem Sealing should be with Torodial sealing rings ( Minimum 2 O-rings). All the valves should be with electrostatic powder coating both inside and outside with pocket less body passage. The Valves shall be supplied with suitable size galvanised bolts and nuts of requied numbers of GKW/ KITO/NLXO/TECHMAN any other equivalent international approved brand. a) Diameter 80 mm b) Working pressure 16 kg/cm2 PN(16) Material for component Parts Body and bonnet : Ductile cast iron of grade GGG50 Stem : AISI 410 Stainless Steel IS 6603 Gr. 12 Cr12 Wedge: Ductile iron GGG50 Rubber lined with EPDM Wedge nut: Bronze Bolts and nuts: Stainless steel Bonnet Gasket: EPDM
1
-
8301
... More
-do- 150mm dia PN(10)
2
-
37224
... More
-do- 200mm dia PN(16)
4
-
118464
... More
-do- 250mm dia PN(10)
1
-
44558
... More
-do- 300mm dia PN(10)
1
-
63051
... More
Ductile Iron check valves without damper arrangement: DI Double flanged tilting disk swing check valves with slanted seat or with stright disc with metallice corrosion proff and wear resistant seal faces with nickel overlay micro finished with body and disc in DI grade GGG50 shaft of stainless steel and bearing of zinc free bronze and surface protection with epoxy liquid of GSK quality. a) Diameter 200 mm b) Working pressure 16 kg/cm2 (PN16) Material of construction: Body : Ductile cast iron grade GGG50 Disc: Ductile cast iron grade GGG50 with valcanised rubber Shaft : Stainless steel Coating : Double coating of epoxy liquid lacquer inside and outside of GSK quality.
2
-
91520
... More
-do- 300mm dia (PN16)
1
-
124373
... More
Pressure Gauge :Supply and delivery at site Air master/Gurusons/Forbes Marshal make glycerene filled Stainless steel pressure gauge of 150mm dia suitable for the above pumpsets with nipple, stop cock & two way cock for cleaning & necessary length of copper tubing .
2
-
2000
... More
Transformer : Supply, erection, electrification and commissioning at site, brand new Board approved make or any other make to be approved by the Board oil immersed naturally cooled continuous duty with copper winding 160 KVA BEE star-2 11 kV/433 volts 3 Ph 50 Hz Dyn 11 vector group distribution transformer conforming to ISS 2026/1977 or its latest amendments fitted with the following and suitable for outdoor installation. a) Dehydrating breather b) Oil conservator c) Drain plug for conservator d) Off ciruit tap changer in steps of 2.5% from + 5% to -15% for high voltage compensation e) Thermometer pack with the thermometer f) Base channel - 2 Nos. g) Lifting lugs 2 Nos. h) Flat rollers i) Connecting pipes j) Oil guage - 1 No. k) Filter valve m) Air release plug - 1 No n) Filter cum drain valve o) Winding temperature indication with alarm and trip contacts p)Oil temperature indication with alarm and trip contacts q) Residual oil drain plug r) Explosion vent s) Detachable Radiators t) cable box for high voltage side u) Cable box for low voltage side. v) Double float gas actuated Buccholz's relay with alarm and trip contacts w) Earthing terminals x) Marshalling Box y) Oil filling hole with cap The transformer shall be fitted with all other standard fittings and painted with high grey paint to shade No. 631 of ISS & shall be supplied with first filling of transformer oil etc., complete (test certificate shall be furnished). The losses shall be as per BEE
1
-
374850
... More
Load break switch for transformers Supply, erection, electrification and commissioning at site brand new any Board approved make load break switch panel suitable for out door unit for operating on 11 kV , 50 Hz 3 phase AC supply. The panelshall consists of the following equipments as details below: a) On load 630 amps air break switch with fuse trip mechanism and tripping circuit suitable for 3 phase, 11kV, 50 Hz AC supply. b) Suitable capacity HRC fuses with trip arrangements. c) Bus bar of adquate capacity d) Panel shall be provided adequate space for accomadation of incoming and outgoing cables
1
-
48000
... More
LT Kiosk Supply, erection, electrification and commissioning at site brand new any Board approved make load break switch panel suitable for out door unit for operating on 440V , 50 Hz 3 phase AC supply. The panel shall consists of the following equipments as details below: 315Amps MCCB 50kA 4 pole fixed type micro processor based Suitable capacity HRC fuses with trip arrangements. Bus bar of adquate capacity Panel shall be provided adequate space for accomadation of incoming and outgoing cables
1
-
40989.83
... More
CONTROL SWITCH GEAR PANELS (75KW) Supply and delivery at site brand new any Board approved make floor mounting, free standing, cubicle type control panel board unit suitable for operation on 3 phase 50 cycles 440 volts AC supply fitted with the following: 250 Amps 4 poleMCCB with current setting range of Amps of any other Board approved make of 50 kA breaking capacity with U/V release, shunt release and suitable thermal release -1 Nos 1 No. Earth leakage relay with resin cast CBCT of Proke's dv's /or any Board approved make. U/V/O/V relay with negative phase sequence protection of Proke's dv's /or any other Board approved make or equivalent- 1 Nos. Phase indicating lamps with switches of any Board approved make- 1 sets Panel mounting version digital type Multi function meter for measuring current, Voltage, P.F, energy etc., of any Board approved make or equivalent.- 1Nos. MS air insulated bus bar chamber with 4 Nos.250 Amps 25 MVA Air insulated bus bar made of high conductivity, high strength aluminium alloy complying with the requirements of grade E91 E of IS 5082, suitably braced with non-hygroscopic SMS supports. Provision shall be made in the bus bar chamber for 3 incoming and 8 outgoing feeders. The bus bar chamber should be of adequate capacity to handle the incoming and out-going cables and for fixing the switchgears as per requirement-1 No. Heavy duty triple pole change over fuse switch of 250 Amps, comprising of two switches mounted on common chasis, complete with handle assembly door interlock and pad locking arrangement with mechanical linkage shorting links and suitable Amps, HRC fuses in sheet metal enclosure of board approved make conforming to the latest IS 4064 Controls and switchegear make - 1No 32 Amps DP load break heavy duty switch fuse unit with rewireable fuses in sheet metal enclosure conforming to the latest ISS 4064 for lighting circuit of any Board approved make.3 No. 32 Amps TP load break heavy duty switch fuse unit with rewireable fuses in sheet metal enclosure conforming to the latest ISS 4064 for lighting circuit BCH / control switch gear make or any other make approved by Board- 2 Nos. 100 Amps TP load break heavy duty switch fuse unit with rewireable fuses in sheet metal enclosure conforming to the latest ISS 4064 for Capacitor of any Board approved make.2 No. Set of cable entries and terminals suitable for numbers, type and size of aluminium conductor power cables, etc. NOTE: 1) The panel board shall be complete with all other required fittings and shall be fabricated using 2mm thick sheet steel and suitable size copper cable/copper wire painted with two coats of a highly corrosion resistant primer applied wet on wet and a finishing coat of synthetic enamel paint of the ash greay shade. 2) The internal wiring shall be done using adequate size insulated electrotinned copper strip or cable of 1.1 KV grade. 3) Manufacturers test certificate is to be furnished to E.E before dispatching the materials to the work site. If any discrepancies are noticed apart from tender specification, suitable action as per tender condition will be taken against the tenderer including black listing of the tenderer. 4) The bus bar chamber should be adequate size to accomadate all incoming, outgoing cable and required switchgear.
1
-
91300
... More
Digital softstarter (minimum75KW). Supply, delivery and commissing at site brand new board approved make or equivalent floor mounting, free standing, cubicle type control panel board unit suitable for operation on 3 phase 50 cycles 400/440 volts AC supply fitted with the following: 160 amps MCCB with fixed and moving contracts fitted with U/V release, shunt release and with suitable thermal release.- 1 Nos . Multi parameter such as current, kwhr, Voltage, KVA reading digital meter of prok devices or any other Board approved make - 1 Nos. Phase indicating lamps with switches of L&T/ BCH/ GE make or any other make approved by the Board - 1 set The soft starter shall have adjustable torque control facilitty to start the sewage pumpsets by reducing the starting current less than 1.5 to 2 times the full load current. It shall have bulit in facilities such as SPP, Over Voltage, Under voltage, Kick start for pump jam conditions , overload, overcurrent etc., for protection of the pumpsets. The starting current shall be controlled by three phase thyristors. The starter shall be provided with minimum 125Amps or suitable capacity by pass contactor The panel shall be provided with cooling fan, louvers with fine mesh to facilitate the cooling of thyristors/ soft starter. The panel should be adequate size to accomadate all incoming, outgoing cable and required switchgear and other accessories.
2
-
174770
... More
Power Capacitors: Supply , delivery, fixing and wiring at site brand new best indegeneous make 3 phase, 50 c/s 440 volts 2 banks of 45 KVAR or suitble KVAR Alluminium Polypropelene type power capacitor conforming to the latest ISS 2834 suitable for indoor installations at a site whose altitude is 50 Note:- The capacitor is required to keep the total power factor of the installation at not less than 0.95 lagging.
90
-
36000
... More
Main side cable:- Supply and delivery at site brand new any Board approved make 3 1/2 x 185 sqmm Aluminum conductors PVC sheathed 1.1 KV class UG Cable conforming to the latest ISS 1554.
80
-
71600
... More
Load side cable:- Supply and deliverty at site brand new Board approved make or any other make to be approved by the Board Aluminium satndard conductors PVC insutated, sheathed steel tape/wire armoured , PVC outer sheated 1.1 KV class UG Cable conforming to the lateat ISS 1554. 3x 120 Sq mm
40
-
21800
... More
3x 35 Sq mm (Capacitor)
20
-
4000
... More
11 KV HT XLPE CABLE: Supply and laying of new Board approved make or any other make to be approved by the Board 3 x 95 sqmm aluminium, earthed, round armoured XLPE HT cable for the purpose of connecting from pole structure to metering cubical and metering cubical to breaker and from breaker to transformer.
120
-
79587.6
... More
Supplying and fixing 2 mm thick perforated cable tray with powder coated paint on MS angle support using necessary GI bolts, nuts and washer or welding as required - 450 x 50 mm
50
-
40900
... More
FIRE FIGHTING EQUIPMENTS : a) Supply and installation of CO2 type fire extinguisher 4.5 Kg capacity with initial charge with wall mounting bracket, ready for use - 2 Nos. b) Supplying and fixing of first aid box comprising of the standard medicines to be provided in the first aid box to give first aid treatment for 50 persons - 1 No. c) Providing shock treatment chart on wall with inside plastic sheet cover and ply wood backplate frame work complete. d) Supply one set of fire buckets(4 Nos) with round bottom made of GI sheets 24 SWG 9 ltrs. capacity painted inside white and outside red with a word `fire' on the face of the bucket along with stand to hang the buckets. f) Supplying rubber gloves, electrical quality, tested to 22KV - 1 Pair g) Supplying and fixing of Danger/No Admission/No Smoking Board made out of MS sheet metal with two coats of non-corrosive enamelled paint.
1
-
15359
... More
Tool Kit: Supply and delivery at site best Taparia/or any other Board approved make and other reputed make tool sets for operation and maintenance of the above pumpsets comprising of the following. a) Double end spanner 1/4" to 1" 1 set b) Screw driver insulated 11" - 1 No c) Screw driver insulated 8" - 1 No d) Cutting puller insulated 8" - 1 No e) Hammer with handle 1 Kg - 1 No f) Pipe wrench 24" 1 No g) Pipe wrench 18" 1 No h) Pipe wrench 12" 1 No i) Hammer with handle 5Kgs 1 No j) Grease gun - 1 No k) Ring spanners 1/4" to 1" - 1 set l) Tongue tester-1No m) Multimeter-1No.( eletromechanical type) n) Megger-500v of MECO or any other approved make-1No.
1
-
9316
... More
Supply and delivery of HT metering Cubicle of HT Metering cubicle of 11 KV class including HT Electronic Tri-Vector Meter of Class-0.2 accuracy with ABT features & DLMS protocol with ToD with all single ratio CTs including 3 CTs and 3 PTs of suitable class, ratio, burden for 3 phase 4 wire metering with transparent cover TTB with 30X8mm Cu bus bars and with load break switch. The metering cubicle shall be Modem compliant with cable entry type for both incoming and outgoing feeders as per ESCOM specifications. (HT Metering box fabricates out of 3mm MS sheet duly epoxy powder coated) with all lead and lifts etc., complete..
1
-
159569.49
... More
Providing and delivery of high voltage insulating mats comfirming to IS 15652 made of Elastomer material with coloured strips of 4" on both side and one side indicating voltage rating 3.3/1.1KV with 2mm thick
20
-
38000
... More
PRESSURE RELIEF VALVES : Supply, delivery and erection of site brand new DOROT( S-100 series)/BERMAD/ ERHALD/ SINGER make pressure relief valve of 80mm dia with maximum permisable pressure 13.0 Kg/cm2 with the following specifications. ( PN 16) 1. Valve should have direct sealing diaphragm activated by line pressure and controlled by 2 way diaphragm operated adjustable pilot valve. 2. Valve should be installed on a Tee junction, which should modulates automatically to maintain present inlet pressure and releive the excess pressure out of the network. MATERIAL OF CONSTRUCTION : 1. Body and Bonnet - Ductile Iron ISO 1083 Grade 450-10. 2. Diaphragm - Natural rubber (standard). 3. Spring - SS 302. 4. Pilot valve - Brass ISO 426. 5. Coating - Electrically applied over baked polyster. 6. End connection - Flanges BS or IS. The outlet of pressure sustaining valve should be connected to sump using MS pipes and fittings.
1
-
99450
... More
Part B:PART:B Erection/Installation of the equipments included in the Facilities: ERECTION OF TRANSFORMER :Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of transformers including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement mortor 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages complete and with MS rail embeded on the top of the platform, hoisting the transformer for the erection on the above platform and erection of the transformer on the platform including the cost of all the materials required labour etc., complete as per direction of Engineer in charge 11/0.433 KV, 160 KVA transformer.
1
-
29402
... More
FORMATION OF TRANSFORMER SUBSTATION:The work involves Construction of platform (1.5x1.5x1.2) mtr in size stone, for erection of metering cubicle, LBS & LT feeder pillar including all materials, labour.Excavation of (1.5x1.5x1) mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement mortor 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages complete and with MS rail embeded on the top of the platform, hoisting the panels and metering cubicle erection on the platform including the cost of all the materials required labour etc., complete. The work also includes supply and spreading of 40 mm down size jelly all round the transformer substation including erection of metering cubicle, breaker and other accessories including cost of all materials and labour required for erection of the above with all lead and lift etc., complete.
1
-
61535
... More
Erection of Control Panel Board and starter panel : on CC foundation including formation of CC foundation in CC 1:2:4 prop. Using all the required materials such as cement, jelly etc., complete including errection of the panel board, on CC foundation using required materials such as MS channel bolts, nuts, washers etc., complete with all lead and lift.
3
-
25500
... More
Erection of pumpsets: Formation of suitable block machine foundation in CC 1:2:4 confirming to the latest ISS 2974 using all the required materials such as cement, sand, jelly etc., complete including necessary earth work refilling curing etc., complete. Erection of the pumpset mounted on the common baseplate on the above foundation using the required material such as foundation bolts, key locks, self interlocking bolts, washer etc., complete levelling, aligning of the pumpsets on the foundation grounding and dynamic balancing using all the required materials including excavation for foundation making pump pits, dewatering etc., complete. The work also includes formation of suitable foundation for Vaccuum pumpsets and erection of the same etc., complete.
2
-
26000
... More
LAYING OF CABLE: LAYING IN TRENCHES/ TRAYS:The works shall include digging of trenches size of 0.60 Mtrs. deep & 1.0 Mtrs. wide providing sand bedding to the cables laying the cable in trench providing cable marking bricks refilling, consolidation the soil etc., complete including the cost of all the materials required for laying the cable as per IE rules labour etc., complete. 3.5 x185 sqmm 1.1 kV class
60
-
10626
... More
3x95 Sqmm 11 KV Class (2run)
50
-
8855
... More
LAYING IN G.I PIPE: Running the cable in 2.9 mm thick suitable size GI pipe above the ground using all the required materials such as GI pipe, clamps, bolts, nuts, washers etc., for fixing the GI pipes to the pole including the cost of these mateials labour etc., complete. 3.5 x 185 sqmm 1.1 kV class
20
-
20310
... More
3x95 Sqmm 11 KV Class (2run)
10
-
10155
... More
Laying of load side cable: Running the cable in existing ducts including properly securing cable in position etc, complete using all the required materials etc, complete. a) 3x 120Sq mm
40
-
1560
... More
b) 3x 35 Sq mm
20
-
780
... More
Cable Terminations: Termination of cable using Copper lugs to the terminal end for solderless crimping to aluminium conductor by adopting cirimping tool. 3.5 x 185 sqmm
15
-
4905
... More
3x120 Sq mm
4
-
760
... More
3x 35 Sq mm
6
-
192
... More
Earthing : Maintenance free earthing system to be installed for the protection including formation of suitable size pit in all soils. The earthing system shall consist of: EARTH ELECTRODE : Earth electrode shall be MS material subsequent hot dip galvanisation of minimum 250 microns / GI tubes to ensure maximum conductivity. The technology shall be either pipe in pipe or pipe in flat. The space in between shall be filled with high conductive compound which resist the corroision. The length of the electrode shall be 3 mtrs .Minimum of 50 mm dia electrode shall be provided for pipe in pipe technology. EARTH ENHANCEMENT COMPOND / Back fill compound: The compound used for backfilling the earth shall enhance the earth material conductivity . The compoundshall reduce the resistivity of the earth to less than 1 ohms. The compond shall be highly conductive and contain homogenous mixture of chemicals. It shall be environmental friendly, non corrosive, not explosive, not cause burns and irritation to eye, skin etc. The compond shall not contain bentonite, salt , charcoal and other dissolvable materials. The compound shall be insoluable in water and shall retain its moisture property uptoi the life of the electrode. The life of the electrode and pit shall not be less than 25 years without any maintainence. The quantity of compound shall not be less than 50 kgs/ pit. EARTH PIT CHAMBER: The earth pit chamber size shall be 300 mm x 300 mm x 5 mm concrete chamber with concrete slab or cover. TESTING POINT: Earth pit testing point shall be provided at the suitable location and above ground level. Testing shall be done after completion of installation. Final grid resistance of each area shall be measured and shall be within 1 ohm. NOTE:-1) All the equipments, such as switchgears, transformers lighting arrestors shall be earthed by two seperate and distinct connection as per IE rules and as required by electrical inspectorate without any extra cost.. 2) Necessary soil testing shall be carried out by the contractor at his own cost before carrying out the work. 3) Since, the earthing points of different equipments and fault level are interconnected , the contractor shall submit the calculations for no of pits required before executing the work. 4) The work also includes connecting the common point of earthing to the earth pit with necessary coupler/ Extothermic welding as per IE rules NOTE:- All the equipments, such as switchgears, transformers lighting arrestors shall be earthed by two seperate and distinct connection with the earth cover as per IE rules and as required by electrical inspectorate without any extra cost..
10
-
111327.4
... More
Supply and fixing of GI earthing strip 50mm x 6mm size for equipment earthing of transformer switch gear, meters motors lighting arrestors etc., The strips shall be laid and connected to the earth pit . The Strips shall be sleeved and protected aganist mechanical damages.
50
-
9750
... More
Supply and fixing of GI earthing strip 25mm x 6mm size for equipment earthing of transformer switch gear, meters motors lighting arrestors etc., The strips shall be laid and connected to the earth pit . The Strips shall be sleeved and protected aganist mechanical damages.
100
-
11500
... More
LAYING AND JOINTING OF MS PIPES AND SPECIALS: Rolling, lowering, laying true to line perfect linking at the joints and jointing of MS pipes specials including fixing of valves, guages for delivery connections of the pumps upto including delivery manifold using all the required materials such as bolts, nuts, washers, rubber packing etc., complete. The work shall include providing pipe supports, conerete chair for suction pipe in CC 1:2:4 prop., wherever necessary upto the end of the pump, using all the requied materials such as sand, cement jelly. The work shall include providing pipe supports, thrusts block in CC 1:2:4 prop., wherever necessary to the end of the delivery manifold, using all the requied materials such as sand, cement jelly including making holes in pump house for laying devliery pipes, packing of holes with CC 1:2:4 etc., complete. (all lead and lift) the works also includes construction of necessary thrust blocks required for delivery manifold arrangement. NOTE: The tenderer should furnish the layout drawing showing the position of valves, Tees, Pipes, providing for future pumpsets etc., and obtain approval from the Chief Engineer before taking up erection work.
1
-
26050
... More
Servicing and commissioning: The pumpsets along with all other elecrical equipments shall be serviced and commissioned in the presence of the Engineer-in-charge of work including trail running for a period of 90 days. The work shall include the following. Providing operating and maintenance manuals of the pumps and allied equipments to the operating personnel. Giving trail run of the pumpsets for a period of 90 days from the date of successful commissioning. The contractor should employ personnel to operate & maintain the pumpset and accessories during the trial run period and should train the Board/Municipal Staff to operate the pumpsets. NOTE: 1. The energy and sewage will be provided by the Board free of cost. 2. The pumpsets along with all the electrical equipments shall be commissioned only when the performance of switch gears, relays are wittnessed by the Executive Engineer in charge of the work and Asst. Executive Engineer of the Board.
1
-
51700
... More
CHAIN LINKED WIRE FENCING : Supply & providing chain linked wire fencing for 11 KV transformer sub-station. The chain linked fencing should be with 2"x2"x8 SWG wire welded with angle iron frames of size 2.5mx2.5m using angle of using 50x50x6mm. The frame be fixed to be supporting channel spacing at 2.5 M size 100x50mm rails transportation and labour for fixing silver painting etc., complete with door with 2.5m size at suitable place including all taxes . Chain linked fencing shall be erected upon size stone masonry structure. The work includes providing & constructing granite/trap/basalt size stone masonry (0.45m wide, for aheight of 0.30m) in foundation cement mortor 1:6 stone hammer dressed in courses not less than 20 cm high, bond stones at two m apart and over plain cement concrete of mix M15 with OPC cement @240kgs, with 40mm and down size graded granite metal coarse aggregates @0.878 cum and fine aggregates @ 0.459 cum machine mixed concrete laid in layers not exceeding 15 cms thick, well compacted, in foundation and plinth for a thickness of 0.15 cm for foundation and 0.10 for coping including cost of all materials, labour, HOM of machinery, curing etc., complete.
45
-
176940
... More
Cable End Seals:- Supply and fixing of 1.1 KV Indoor and outdoor type RAYCHEM/M SEAL /or any other Board approved make heat shrinkable /Push On type cable end seals with all required materials including copper lugs and terminals.,etc.,complete. Suitable 3 X 95 sqmm, 11 KV XLPE cable, outdoor earthed type
2
-
9528.16
... More
Cable End Seals:- Supply and fixing of 1.1 KV Indoor and outdoor type RAYCHEM/M SEAL /or any other Board approved make heat shrinkable /Push On type cable end seals with all required materials including copper lugs and terminals.,etc.,complete. Suitable 3 X 95 sqmm, 11 KV XLPE cable indoor earthed type
4
-
18086.84
... More
Dismantling of all Existing pumpsets and delivery and suction pipes and valves:Dismantaling of existing 02 nos of HSC Pumpsets by removing the existing shafts, couplings, bearing etc.,with out damaging the pumpset and with out hampering the regular water supply distribution and removing of the existing suction pipe & Delivery pipes , valves etc including closing of holes in pump house with CC 1:2:4 etc., complete. The work also includes clearing the debris from the site and disposing off the debris with all lead and lift as per the direcion of the Engineer-in-Charge. The dismantaling work is to be carried out in such a way that the place shall be suitable for installing new pumps . The released materials shall be returned to the board stores as per the directions of Engineer-in-Charge. - At pumphouse Note: The Contractor is advised to visit the site to know the actual work before quoting the rates.
1
-
7588
... More
Dismantaling of existing Control panel , starter, capacitor bank, load side and capacitor cables etc., with out damaging the equipments including shifting of the released equipments to CMC stores .The work also includes clearing the debris from the site and disposing off the debris with all lead and lift as per the direcion of the Engineer-in-Charge. The dismantaling work is to be carried out in such a way that the place shall be suitable for installing new panels. The released materials shall be returned to the board stores as per the directions of Engineer-in-Charge. - At pumphouse Note: The Contractor is advised to visit the site to know the actual work before quoting the rates.
1
-
6589
... More
Dismantaling of existing Metering cubicle, transformer, main side cable, 11KV cable poles structure , fencing etc., with out damaging the equipments including shifting of the released equipments to CMC stores/BESCOM stores .The work also includes clearing the debris from the site and disposing off the debris with all lead and lift as per the direcion of the Engineer-in-Charge. The dismantaling work is to be carried out in such a way that the place shall be suitable for installing new equipment. as per the directions of Engineer-in-Charge. - At pumphouse Note: The Contractor is advised to visit the site to know the actual work before quoting the rates.
1
-
10000
... More
Supply and fixing of Horizontal Mechanical Wotlman type hermetically sealed water meters with copper Glass register with IP 68 protection. The meters shall be removalbe meachnaism type manufactured as ISO 4064-1: 1993 with MID certification . The merts shall be capable of transmitting consumption data on daily basis t central server through GSM/GPRS. The meter interface unit shall be fitted to the mert without wire. The consumption data shall be collected, stored and analysed by data logger. The data logger should provide data like flow rate, total flow, consumption analysis, reverse flow, meter tampering, daily flow distribution, leakage detection. The data logger shall also send alarams on blocked meter, flow rate above limit, pressure below or above limits. -300mm dia
1
-
286900
... More
Supply & fabrication of ISMB 250 beam to the pumphouse of 4.00 x 6.00 meter size suitable to carry gantry to takeup the load of 2 MT ( the beam will be supported on on two sides of the wall including painting two coats by anticorrosive approved colour over one coat of primer ). ( A detailed design and drawings are to be got approved before execution)Etc., complete with all lead and lift.
484.9
-
74674.6
... More
Supply & Fabrication of Gantry builtup beam of ISMB 300 to takeup 3.0 MT load with 5.8 Mtr. Span including painting two coats by anticorrosive approved colour over one coat of primer ) with all lead and lift etc., complete. ( A detailed design and drawings are to be got approved before execution)
256.36
-
39479.44
... More
Supply & fabrication of Channels of size ISLC 200 of 4 Nos. (1.2 Mtr. Length) Etc., complete with all lead and lift.
98.88
-
15227.52
... More
Supply & fabrication of 25 x 25 mm MS square bar to suite the 4x6 Mtr. dia pumphouse Etc., complete with all lead and lift.
63.78
-
9822.12
... More
Supply & fabrication of Stiffner plate 25 mm thick to be welded on both flanges to girder and channels jointing of ends, end carriage base plate, end carriage end plate, ring girder jointing and for fixing in the concrete and plate welded. including two coats of anticorrosive paint of approved colour over one coat of primer. .Etc., complete with all lead and lift
71
-
10934
... More
Supply fabrication & erection of CI wheels with Ball bearings, gears, pinions, universal joints, (double set) the long shaft and with gear mechanism for operation, cross trolly 2.0 MT Capacity with ascessories including two coats of anticorrosive paints over one coat of primer.
1
-
55000
... More
Supply and hoisting of 2.0 MT Capacity Spur geared INDEF Make chain pully block with 7.00 Mtr. Lifting chain
1
-
60000